ENS 48010
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
07:35 Jun 11, 2012 | |
| Title | Technical Support Center Out of Service for Planned Maintenance |
| Event Description | On June 11, 2012, at approximately 0335 hours0.00388 days <br />0.0931 hours <br />5.539021e-4 weeks <br />1.274675e-4 months <br />, the Hope Creek Technical Support Center (TSC) ventilation system was removed from service to perform planned maintenance to the system. The maintenance consists of a 12-year preventative maintenance overhaul of the ventilation supply fan and emergency filtration unit. The removal of ventilation potentially affects the TSC habitability during a declared emergency requiring activation. Appropriate compensatory measures are in place while ventilation is out of service. The Emergency Response Organization duty team has been notified of the maintenance and the possible need to activate the TSC in an alternate location. The ventilation system is scheduled to be out of service for approximately 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br />.
The licensee has notified the NRC Resident Inspector. The local township will be notified.
The planned maintenance was completed and the TSC ventilation was returned to an operable status as of 0245 EDT on June 13, 2012. The TSC was not activated during the planned maintenance. The licensee notified the NRC Resident Inspector. Notified R1DO (DeFrancisco). |
| Where | |
|---|---|
| Hope Creek New Jersey (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
| Time - Person (Reporting Time:+-3.65 h-0.152 days <br />-0.0217 weeks <br />-0.005 months <br />) | |
| Opened: | Tom Fowler 03:56 Jun 11, 2012 |
| NRC Officer: | Dong Park |
| Last Updated: | Jun 18, 2012 |
| 48010 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 48010\u003C/a\u003E - \u003Ca href=\"/Hope_Creek\" title=\"Hope Creek\"\u003EHope Creek\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003ETechnical Support Center Out of Service for Planned Maintenance\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 48010 - Hope Creek\n","link":"","lat":39.46618888888889,"lon":-75.53605833333333,"icon":"/w/images/c/cc/PSEG_icon.png"}],"imageoverlays":null} | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 578782025-08-20T00:30:00020 August 2025 00:30:00
[Table view]10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Major Loss of Emergency Assesment Capability ENS 526982017-04-20T17:06:00020 April 2017 17:06:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Seismic Monitor Panel Non-Functional ENS 511412015-06-09T07:10:0009 June 2015 07:10:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Hope Creek Technical Support Center Removed from Service for Planned Maintenance ENS 503152014-07-28T05:18:00028 July 2014 05:18:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Meteorological Data to the Site ENS 503022014-07-24T00:27:00024 July 2014 00:27:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Common Site Temporary Loss of Meteorological Data ENS 498902014-03-11T07:00:00011 March 2014 07:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Ventilation Removed from Service for Planned Maintenance ENS 498262014-02-14T06:13:00014 February 2014 06:13:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Meteorological Tower Out-Of-Service Due to Weather ENS 489082013-04-10T13:30:00010 April 2013 13:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Notification System Telephone ENS 489052013-04-09T17:15:0009 April 2013 17:15:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Notification System Telephone ENS 485602012-12-05T14:21:0005 December 2012 14:21:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Ventilation Removed from Service for Maintenance ENS 484042012-10-13T01:00:00013 October 2012 01:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Removed from Service for Planned Maintenance ENS 483602012-09-29T12:09:00029 September 2012 12:09:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power Supply for Nuclear Emergency Telecommunication System ENS 480102012-06-11T07:35:00011 June 2012 07:35:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Technical Support Center Out of Service for Planned Maintenance ENS 465382011-01-14T09:26:00014 January 2011 09:26:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Ens and Erds Capability Due to a Failure of the Phone System Ups ENS 462592010-09-20T11:00:00020 September 2010 11:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Erds and Spds Out of Service for Computer Upgrade ENS 449952009-04-17T06:07:00017 April 2009 06:07:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Maintenance on Spds and Erds ENS 437572007-10-29T23:30:00029 October 2007 23:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power to Technical Support Center (Tsc) ENS 431912007-02-27T18:11:00027 February 2007 18:11:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Maintenance on Spds ENS 423322006-02-12T13:00:00012 February 2006 13:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Communications - Loss of Sirens ENS 423312006-02-12T09:00:00012 February 2006 09:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Ability to Collect Meteorological Data ENS 420662005-10-20T18:20:00020 October 2005 18:20:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Upgrade of Safety Parameter Display System ENS 418122005-06-29T18:40:00029 June 2005 18:40:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Sirens Due to Power Outage ENS 409812004-08-24T17:30:00024 August 2004 17:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness North Plant Vent Radiation Monitor Skid Test Connection Valve Inadvertently Left Open. ENS 401722003-09-19T01:11:00019 September 2003 01:11:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Siren Capability Due to Adverse Weather Conditions 2025-08-20T00:30:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_48010&oldid=423826"