1 PMILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET P.O. BOX 8699 PHILADELPHIA, PA.19101 (215)841 4000 February 8, 1983 Docket No. 50-278 Mr. R. C. Haynes, Administrator Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19046
SUBJECT:
Licensee Event Reoort Narrative Descriotion
Dear Mr. Haynes:
The following occurrence was reported to Mr. A.
R. Blough of Region I U.S. NRC on January 4, 1983:
Reference:
Docket No. 50-278 Report Number:
3-83-02/IT-0 Report Date:
February 8, 1983 Event Date:
January 26, 1983 Facility:
Peach Bottom Atomic Power Station RD 1, Delta, PA 17314 Technical Specification Reference:
Techncial Specification 3.7.D.2 states that "In the event any isolation valve specified on Table 3.7.1 becomes inoperable, i
reactor power operation may continue orovided at least one valve in each line having an inoperable valve shall be in the mode corresponding to the isolated condition."
The HPCI turbine exhaust vacuum breaker isolation valve is included in Table 3.7.1.
Specification 3.5.C.2 states that, "From and after the date that the HPCI subsystem is made or found to be inoperable for any reason, continued reactor operation is permissible only during the succeeding seven days unless such subsystem is sooner made operable, providing that during such seven days all active components of the ADS subsystem, the RCIC system, the LPCI subsystem and both core spray subsystems are operable."
If these requirements cannot be met, "an orderly shutdown shall be initiated and the reactor shall be in a Cold Shutdown Condition within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />," per Technical Specification 3.5.C.3.
l 8302220121 830208 PDR ADOCK 05000R78 i
s PDR
.-f.E't 3,
Mr. R. C. Haynes Page 2
l Description of the Event:
During local leak rate testing of the HPCI turbine exhaust vacuum breaker isolation valve, with the unit operating at 860 MWe, the valve failed to fully close.
A manual valve in the same line was closed and the HPCI system was declared inoperable.
Surveillance testing of redundant backup systems was initiated per Technical Specificaition 3.5.C.2.
When the RCIC surveillance test was performed, the turbine throttle valve motor breaker tripped during the portion of the test that checks the turbine remote throttle valve reset capability.
An orderly unit shutdown was immediately initiated per Technical Specification 3.5.C.3.
Following adjustment of the linkage on the RCIC turbine throttle valve motor breaker thermal reset switch, a successful curveillance test was completed on the valve and RCIC system.
With RCIC operability re-established the shutdown was terminated and reactor power increased.
The resident NRC Inspector was promptly notified of the problems with the HPCI vacuum breaker isolation valve and the declaration of HPCI inoperable. However, the latter problem with the RCIC throttle valve was inadvertently not reported to the resident Inspector nor wae the NRC ' Operations Center notified, because the RCIC throttle valve problem was corrected within 30 ininutes.
Probable Consecuences of the Event:
The motor operated HPCI vacuum breaker isolation valve is normally open to permit the vacuum breakers to break vacuum between the HPCI turbine exhaust line and the torus air space.
It closes automatically if primary coolant pressure is less than 100 psig and drywell pressure is greater than 2 psig.
This function isolates the torus air space from the HPCI turbine exhaust line during periods when HPCI operability is not required.
It also permits torus water to seal the HPCI exhaust line check valve after HPCI operation is no longer required.
When the HPCI vacuum breaker isolation valve failed to fully close, an in-line manual isolation valve was closed to maintain containment integrity.
The second isolation valve in this penetration is the HPCI exhaust line check valve, which was operable during this period.
With the vacuum breaker line isolated, initial operation of the HPCI system would not be affected.
However, in this configuration, if the HPCI system is cycled on.and off, a potential exists for torus water to be drawn into the HPCI turbine exhaust line, creating a significant backpressure on the turbine on successive starts.
Mr. R. C. Haynes Page 3
The safety significance of the vacuum breaker isolation valve to fully close is minimal because the in-line check valve was operable and in the closed positon.
Continued operation of the unit with the HPCI manual isolation valve closed is conservative because the HPCI system was maintained in an operable condition.
The RCIC system was tested due to declaring the HPCI system inoperable.
The RCIC turbine throttle valve is normally in the open position and was therefore capable of starting automatically and operating properly upon initiation prior to performance of the surveillance test.
However, if the RCIC turbine had tripped during operation, it could not have been re-started from the control room.
The RCIC throttle valve was inoperable for approximately 30 minutes during which time the mechanical linkage on the reset switch on the throttle valve motor breaker compartment was adjusted to reset the thermal overloads.
The HPCI system had initial operating capability and the ADS was operable.
Since an orderly shutdown was immediately initiated, and the RCIC was only inoperable for a short time period, the safety significance of this event is considered minimal.
Cause of the Event
Routine leak rate testing of the motor opearated HPCI vacuum breaker isolation valve indicated that the limitorque operrtor prevented the valve from closing fully.
Inspection of operator internals indicated that the gear train lubricating grease had solidified preventing the operator from fully closing the valve.
During the surveillance test of the RCIC system, the throttle valve was tripped and reset.
During relatching of the valve the thermal overloads on the valve motor tripped, due to motor overcurrent.
Corrective Action
When the HPCI motor operated vacuum breaker isolation valve failed to close, immediate corrective action was taken by closing the in-line manual isolation valve and declaring HPCI inoperable.
Surveillance testing of back-up ECCS systems was initiated immediately per the Technical Specifications.
On January 27, 1983, the motor operator was repaired by removing the hardened lubricant and applying new lubricant to the operator gear train.
At this time, the limit switches and toroue switches were checked and realigned and a successful local leak rate test was performed late on January 27, 1983.
Mr. R. C. Haynes Page 4
The RCIC system was returned to operable status within 30 minutes of the failure.
Following adjustment of the reset linkage on the throttle valve motor thermal overloads, RCIC throttle valve and RCIC system operability was re-established and the unit shutdown was terminated.
Further preventive maintenance was performed on the throttle valve on January 27, 1983 by lubricating the valve stem and additional stroking to preclude valve motor overcurrent.
Due to the failure to properly report the RCIC inoperability, a portion of the licensed operator requalification program will be dedicated to this subject during the second requalification lecture cycle.
I Sincerely,
/
/MM/-
/. Cooney M4 perintendent eneration Divison-Nuclear cc Mr. Norman Haller, Director Office of Management & Program Analysis U.S. Nuclear Regulatory Commission Washington, DC 20555 A. R. Blough Site Inspector P.O. Box 399 Delta, PA 17314-0399
- - w e
, ~ -
e m
,m..
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000278/LER-1983-001-03, /03L-0:on 830103,setpoint of Main Steam Line Low Pressure Switch a (PS-3-2-134A) Found Approx 33% Below Min Tech Spec Limit.Caused by Setpoint Drift of Barksdate Model B2T12SS Pressure Switch.Instrument Recalibr | /03L-0:on 830103,setpoint of Main Steam Line Low Pressure Switch a (PS-3-2-134A) Found Approx 33% Below Min Tech Spec Limit.Caused by Setpoint Drift of Barksdate Model B2T12SS Pressure Switch.Instrument Recalibr | | | 05000277/LER-1983-002-01, /01T-0:on 830120,RCIC Inboard Steam Supply Isolation Valve Found in Open Position.Caused by Operator Mistakenly Removing Feed from Valve.Operators Counseled to Take Better Precautions | /01T-0:on 830120,RCIC Inboard Steam Supply Isolation Valve Found in Open Position.Caused by Operator Mistakenly Removing Feed from Valve.Operators Counseled to Take Better Precautions | | | 05000278/LER-1983-002, Forwards LER 83-002/01T-0.Detailed Event Analysis Submitted | Forwards LER 83-002/01T-0.Detailed Event Analysis Submitted | | | 05000278/LER-1983-002-01, /01T-0:on 830126,during Local Leak Rate Testing of HPCI Breaker Isolation Valve,Valve Did Not Fully Close & HPCI Declared Inoperable.Caused by Solidified Grease in Operator Gear Train.Operator Cleaned & Successfully Tested | /01T-0:on 830126,during Local Leak Rate Testing of HPCI Breaker Isolation Valve,Valve Did Not Fully Close & HPCI Declared Inoperable.Caused by Solidified Grease in Operator Gear Train.Operator Cleaned & Successfully Tested | | | 05000278/LER-1983-003-03, /03L-0:on 830127,HEA Relay on Emergency Safeguard Bus E23 Tripped Normal Supply & Locked Out Backup & Diesel Supplies.Caused by Operation of Relay on Bus E23.Activating Devices May Be Defective & Will Be Bench Tested | /03L-0:on 830127,HEA Relay on Emergency Safeguard Bus E23 Tripped Normal Supply & Locked Out Backup & Diesel Supplies.Caused by Operation of Relay on Bus E23.Activating Devices May Be Defective & Will Be Bench Tested | | | 05000277/LER-1983-003-03, /03L-0:on 830206,coolant Leak Discovered in Cooling Sys of Diesel Driven Fire Pump.Caused by Leaking Water Pump Shaft Seal.Replacement Pump Placed in Svc on 830209 | /03L-0:on 830206,coolant Leak Discovered in Cooling Sys of Diesel Driven Fire Pump.Caused by Leaking Water Pump Shaft Seal.Replacement Pump Placed in Svc on 830209 | | | 05000277/LER-1983-004-03, /03L-0:on 830424,refueling Floor Ventilation Radiation Monitor RE2-17-432D Experienced Downscale Spike. Caused by Defective Gieger/Mueller Tube.Tube Replaced & Faulty Connector Rebuilt | /03L-0:on 830424,refueling Floor Ventilation Radiation Monitor RE2-17-432D Experienced Downscale Spike. Caused by Defective Gieger/Mueller Tube.Tube Replaced & Faulty Connector Rebuilt | | | 05000278/LER-1983-004-03, /03L-0:on 830127,during Power Operation,Torus Purge Air Supply AO-3521-B Did Not Fully Close Upon Completion of Deinerting Operations.Caused by Piece of Plastic Falling Through Pipe Chase.Plastic Removed | /03L-0:on 830127,during Power Operation,Torus Purge Air Supply AO-3521-B Did Not Fully Close Upon Completion of Deinerting Operations.Caused by Piece of Plastic Falling Through Pipe Chase.Plastic Removed | | | 05000278/LER-1983-005-01, /01T-0:on 830312,refueling Bridge Interlock Inoperable.Caused by out-of-adjustment Interlock Switch. Switch Adjusted | /01T-0:on 830312,refueling Bridge Interlock Inoperable.Caused by out-of-adjustment Interlock Switch. Switch Adjusted | | | 05000278/LER-1983-005, Forwards LER 83-005/01T-0.Detailed Event Analysis Submitted | Forwards LER 83-005/01T-0.Detailed Event Analysis Submitted | | | 05000277/LER-1983-005-03, /03L-0:on 830313,low Flow Alarm on Plant Stack Radiation Monitor Annunciated.Caused by Broken Pump Drive Belt.Belt Replaced | /03L-0:on 830313,low Flow Alarm on Plant Stack Radiation Monitor Annunciated.Caused by Broken Pump Drive Belt.Belt Replaced | | | 05000278/LER-1983-006-01, /01T-0:on 830131,during Local Leak Rate Testing of B Containment Atmosphere Dilution Nitrogen Injection Penetration,Determined Valve Leaking Excessively.Caused by Scored Seat & Foreign Matl.Bonnet,Stem & Plug Replaced | /01T-0:on 830131,during Local Leak Rate Testing of B Containment Atmosphere Dilution Nitrogen Injection Penetration,Determined Valve Leaking Excessively.Caused by Scored Seat & Foreign Matl.Bonnet,Stem & Plug Replaced | | | 05000278/LER-1983-006, Forwards LER 83-006/01T-0.Detailed Event Analysis Submitted | Forwards LER 83-006/01T-0.Detailed Event Analysis Submitted | | | 05000277/LER-1983-006-01, /01T-0:on 830323,investigation of Spike on Torus Level Recorder Determined That Test Apparatus Left in Svc from 830320 W/Instrument Drain Valve Left Open Providing Potential Containment Leak Path.Caused by Personnel Error | /01T-0:on 830323,investigation of Spike on Torus Level Recorder Determined That Test Apparatus Left in Svc from 830320 W/Instrument Drain Valve Left Open Providing Potential Containment Leak Path.Caused by Personnel Error | | | 05000277/LER-1983-006, Forwards LER 83-006/01T-0.Detailed Event Analysis Submitted | Forwards LER 83-006/01T-0.Detailed Event Analysis Submitted | | | 05000277/LER-1983-007-03, /03L-0:on 830404,narrow Range Torus Level Transmitter Lt 8027A Determined to Be Out of Calibr.Caused by Instrument Drift.Instrument Recalibr & Returned to Svc | /03L-0:on 830404,narrow Range Torus Level Transmitter Lt 8027A Determined to Be Out of Calibr.Caused by Instrument Drift.Instrument Recalibr & Returned to Svc | | | 05000278/LER-1983-007, Forwards LER 83-007/01T-0.Detailed Event Analysis Submitted | Forwards LER 83-007/01T-0.Detailed Event Analysis Submitted | | | 05000278/LER-1983-008-01, /01T-0:on 830214,inboard Main Steam Drain Valve MO-2-74 & Inboard MSIVs 80:A,C & D Failed to Meet Tech Spec Leak Test Limits.Cause Not Known.Failed Valves Scheduled for maint.Thirty-day Followup Rept to Be Submitted After Ma | /01T-0:on 830214,inboard Main Steam Drain Valve MO-2-74 & Inboard MSIVs 80:A,C & D Failed to Meet Tech Spec Leak Test Limits.Cause Not Known.Failed Valves Scheduled for maint.Thirty-day Followup Rept to Be Submitted After Maint | | | 05000277/LER-1983-008-03, /03L-0:on 830407,HPCI High Steam Flow Isolation Switch DPIS-2-23-77 Setpoint Found Above Tech Spec Limit. Caused by Setpoint Drift of Barton Model 288.Instrument Recalibr,Tested & Returned to Svc | /03L-0:on 830407,HPCI High Steam Flow Isolation Switch DPIS-2-23-77 Setpoint Found Above Tech Spec Limit. Caused by Setpoint Drift of Barton Model 288.Instrument Recalibr,Tested & Returned to Svc | | | 05000278/LER-1983-008, Followup LER 83-008/01X-1:on 830214,during Refueling Outage, Surveillance Testing Indicated Combined Leakage for Listed Valves Exceeded Limits or Failed to Meet Requirements.Caused by Seat Surface Degradation | Followup LER 83-008/01X-1:on 830214,during Refueling Outage, Surveillance Testing Indicated Combined Leakage for Listed Valves Exceeded Limits or Failed to Meet Requirements.Caused by Seat Surface Degradation | | | 05000277/LER-1983-009-03, /03L-0:on 830324,during Surveillance Testing,Smoke Detector in Drywell Failed to Provide Audible Alarm Code or Annunciate in Control Room.Caused by Defective Detector Circuit Board.Board Replaced,Tested & Returned to Svc | /03L-0:on 830324,during Surveillance Testing,Smoke Detector in Drywell Failed to Provide Audible Alarm Code or Annunciate in Control Room.Caused by Defective Detector Circuit Board.Board Replaced,Tested & Returned to Svc | | | 05000278/LER-1983-009-01, /01T-0:on 830908,during Surveillance Testing W/One Diesel Generator Inoperable,Breaker Between Diesel Generator E-1 & Emergency Bus E-13 Failed to Close Manually.Cause Unknown.Breaker Tested Successfully | /01T-0:on 830908,during Surveillance Testing W/One Diesel Generator Inoperable,Breaker Between Diesel Generator E-1 & Emergency Bus E-13 Failed to Close Manually.Cause Unknown.Breaker Tested Successfully | | | 05000278/LER-1983-010-03, /03L-0:on 830222,during Refueling Outage,Testing of Recently Installed Fire Detection Sys Mod Revealed Previously Undetected Wiring Errors Between Two Sets of Two Annunciator Circuits.Caused by Wiring Error | /03L-0:on 830222,during Refueling Outage,Testing of Recently Installed Fire Detection Sys Mod Revealed Previously Undetected Wiring Errors Between Two Sets of Two Annunciator Circuits.Caused by Wiring Error | | | 05000277/LER-1983-010-03, /03L-0:on 830427,sample Line Flow Meter Indicated No Flow & 3-way Selector Valve SV-2524 Found Stuck.Caused by Dirt Buildup Inside Solenoid Valve, (Asco Model S-36-734). Valve Tapped & Flow Returned | /03L-0:on 830427,sample Line Flow Meter Indicated No Flow & 3-way Selector Valve SV-2524 Found Stuck.Caused by Dirt Buildup Inside Solenoid Valve, (Asco Model S-36-734). Valve Tapped & Flow Returned | | | 05000278/LER-1983-011-01, /01T-0:on 830407,loss of Control Rod Position Indication Occurred from Control Rods 22-47,58-31 & 54-15. Caused by Improper Use of Jumper Procedure on 830311,26 & 0402.Jumpers Removed.Jumper Procedure Suspended | /01T-0:on 830407,loss of Control Rod Position Indication Occurred from Control Rods 22-47,58-31 & 54-15. Caused by Improper Use of Jumper Procedure on 830311,26 & 0402.Jumpers Removed.Jumper Procedure Suspended | | | 05000278/LER-1983-011, Forwards LER 83-011/01T-0.Detailed Event Analysis Submitted | Forwards LER 83-011/01T-0.Detailed Event Analysis Submitted | | | 05000278/LER-1983-012-01, /01T-0:on 830425,during Refueling Outage,While Performing Nde,Intergranular Stress Corrosion Cracking Indications Found in Heat Affected Zone of 12 Welds.Caused by Stress Corrosion.Weld Insp Increased | /01T-0:on 830425,during Refueling Outage,While Performing Nde,Intergranular Stress Corrosion Cracking Indications Found in Heat Affected Zone of 12 Welds.Caused by Stress Corrosion.Weld Insp Increased | | | 05000278/LER-1983-012, Forwards LER 83-012/-01T-0.Detailed Event Analysis Encl | Forwards LER 83-012/-01T-0.Detailed Event Analysis Encl | | | 05000277/LER-1983-012-01, /01P:on 830511,insp of Fire Barrier Penetrations Revealed Inadequacies in Penetration Seals.Caused by Const or Design Error & Inadequate Initial Insp.Fire Watches Posted & Addl Insps Initiated | /01P:on 830511,insp of Fire Barrier Penetrations Revealed Inadequacies in Penetration Seals.Caused by Const or Design Error & Inadequate Initial Insp.Fire Watches Posted & Addl Insps Initiated | | | 05000277/LER-1983-013-03, /03L-0:on 830503,fluctuating Readings Observed on Iodine Monitor & Downscale Reading Found on Gas Monitor. Caused by Poor Connections in Drywell Air Sampling Radiation Detector Circuitry Due to Oxidation Buildup on Connector | /03L-0:on 830503,fluctuating Readings Observed on Iodine Monitor & Downscale Reading Found on Gas Monitor. Caused by Poor Connections in Drywell Air Sampling Radiation Detector Circuitry Due to Oxidation Buildup on Connectors | | | 05000278/LER-1983-013-03, /03L-0:on 830926,suction Valve 14-70 on Torus Dewatering Pump Declared Inoperable & Valve 14-71 Closed. Caused by Defective Thermal Overload Switch.Switch Replaced | /03L-0:on 830926,suction Valve 14-70 on Torus Dewatering Pump Declared Inoperable & Valve 14-71 Closed. Caused by Defective Thermal Overload Switch.Switch Replaced | | | 05000277/LER-1983-014-03, /03L-0:on 830812,control Room Fire Barrier Discovered W/O Fire Damper in One Ventilation Duct Penetration.Caused by Damper Not Incorporated Into Original Ventilation Sys Installation.New Damper on Order | /03L-0:on 830812,control Room Fire Barrier Discovered W/O Fire Damper in One Ventilation Duct Penetration.Caused by Damper Not Incorporated Into Original Ventilation Sys Installation.New Damper on Order | | | 05000278/LER-1983-014-03, /03L-0:on 831004,while Shutdown W/Reactor Mode Switch in Refuel Position,Second Control Rod Could Be Selected When Control Rod 02-35 Selected.Caused by Open Diode on GE Relay Card.Diode Replaced | /03L-0:on 831004,while Shutdown W/Reactor Mode Switch in Refuel Position,Second Control Rod Could Be Selected When Control Rod 02-35 Selected.Caused by Open Diode on GE Relay Card.Diode Replaced | | | 05000277/LER-1983-015-03, /03L-0:on 830611,while Performing Surveillance Test,Reactor Water Cleanup Inboard Isolation Valve MO-2-12-15 Failed to Close.Caused by Open Auxiliary Contact in Motor Control Ctr,Preventing Close Signal.Contact Freed | /03L-0:on 830611,while Performing Surveillance Test,Reactor Water Cleanup Inboard Isolation Valve MO-2-12-15 Failed to Close.Caused by Open Auxiliary Contact in Motor Control Ctr,Preventing Close Signal.Contact Freed | | | 05000278/LER-1983-015-03, /03L-0:on 831013,during HPCI Sys Testing,Both HPCI Turbine Exhaust Rupture Discs Failed Due to High Pressure.Hpci Declared Inoperable.Caused by Water in Exhaust Line During Turbine Start.Disc Replaced | /03L-0:on 831013,during HPCI Sys Testing,Both HPCI Turbine Exhaust Rupture Discs Failed Due to High Pressure.Hpci Declared Inoperable.Caused by Water in Exhaust Line During Turbine Start.Disc Replaced | | | 05000277/LER-1983-016-03, Isolation Valve SV2671C in One Sample Line to Drywell Oxygen Analyzers Failed to Fully Close.Caused by Bent Stem in Isolation Valve.Valve Disassembled & Damaged Parts Replaced | Isolation Valve SV2671C in One Sample Line to Drywell Oxygen Analyzers Failed to Fully Close.Caused by Bent Stem in Isolation Valve.Valve Disassembled & Damaged Parts Replaced | | | 05000278/LER-1983-016-03, /03L-0:on 831017,during Startup,Moisture Sensor in Moisture Monitoring Sys Failed.Caused by Defective Techmark Ltd Sensor.Sensor Will Be Replaced | /03L-0:on 831017,during Startup,Moisture Sensor in Moisture Monitoring Sys Failed.Caused by Defective Techmark Ltd Sensor.Sensor Will Be Replaced | | | 05000277/LER-1983-017-03, /03L-0:on 830620,offsite Electrical Source Taken Out of Svc Due to Defective Transformer Relief Device.Relief Device Replaced & Electrical Sys Returned to Normal Configuration | /03L-0:on 830620,offsite Electrical Source Taken Out of Svc Due to Defective Transformer Relief Device.Relief Device Replaced & Electrical Sys Returned to Normal Configuration | | | 05000278/LER-1983-017-03, /03L-0:on 831020,during post-refueling Outage Startup,W/Unit at Low Power,Offgas Radiation Monitoring Sys Found Inoperable.Caused by Condensation in Offgas Sample Lines.Water Withdrawn from Sample Lines | /03L-0:on 831020,during post-refueling Outage Startup,W/Unit at Low Power,Offgas Radiation Monitoring Sys Found Inoperable.Caused by Condensation in Offgas Sample Lines.Water Withdrawn from Sample Lines | | | 05000277/LER-1983-018-03, /03L-0:on 830624,while Performing HPCI Sys Logic Functional Surveillance Test,Hpci Turbine Control Valve Failed to Open.Caused by Burned Out Dropping Resistor in Power Supply to Woodward Emergency Generator Motor | /03L-0:on 830624,while Performing HPCI Sys Logic Functional Surveillance Test,Hpci Turbine Control Valve Failed to Open.Caused by Burned Out Dropping Resistor in Power Supply to Woodward Emergency Generator Motor | | | 05000277/LER-1983-019-03, /03L-0:on 830626,during Surveillance Testing, Standby Gas Treatment Filter Train Outlet Valve AO-20475-2 Failed to Open.Caused by Binding in Solenoid Valve Mfg by Asco.Solenoid Replaced & Valve Returned to Svc | /03L-0:on 830626,during Surveillance Testing, Standby Gas Treatment Filter Train Outlet Valve AO-20475-2 Failed to Open.Caused by Binding in Solenoid Valve Mfg by Asco.Solenoid Replaced & Valve Returned to Svc | | | 05000278/LER-1983-019-03, /03L-0:on 831031,core Spray Pump Room D Cooling Fans H & G Failed to Automatically Start.Caused by Blown 6-amp Fuse within Auxiliary Control Circuitry.Fuse Replaced | /03L-0:on 831031,core Spray Pump Room D Cooling Fans H & G Failed to Automatically Start.Caused by Blown 6-amp Fuse within Auxiliary Control Circuitry.Fuse Replaced | | | 05000277/LER-1983-020-03, /03L-0:on 830629,during Visual Investigation of Penetration Fire Barriers,Inadequacies Found in Penetration Seals in Control Room.Caused by Const or Design Error. Temporary Sealing Followed by Seal Upgrade in Progress | /03L-0:on 830629,during Visual Investigation of Penetration Fire Barriers,Inadequacies Found in Penetration Seals in Control Room.Caused by Const or Design Error. Temporary Sealing Followed by Seal Upgrade in Progress | | | 05000278/LER-1983-020-03, /03L-0:on 831123,discovered RCIC Turbine Steam Supply Low Pressure Isolation Switch Out of Calibr.Caused by Setpoint Drift.Instrument Recalibr & Returned to Svc | /03L-0:on 831123,discovered RCIC Turbine Steam Supply Low Pressure Isolation Switch Out of Calibr.Caused by Setpoint Drift.Instrument Recalibr & Returned to Svc | | | 05000277/LER-1983-021-03, /03L-0:on 830907,during Surveillance Testing of Diesel Generator E-3,operators Noted That Output Power Swinging & Exhaust Temp High.Caused by Failed Elliott Turbocharger & Excess Fuel Igniting Exhaust | /03L-0:on 830907,during Surveillance Testing of Diesel Generator E-3,operators Noted That Output Power Swinging & Exhaust Temp High.Caused by Failed Elliott Turbocharger & Excess Fuel Igniting Exhaust | | | 05000278/LER-1983-021-03, /03L-0:on 831203,moisture Monitoring Sys Indicated Moisture Alarm & Trouble Alarm at Weld 2-AHH-2 on 12-inch Recirculation Piping Loop A.Caused by Logic Board Misinterpretation of Sensor Output | /03L-0:on 831203,moisture Monitoring Sys Indicated Moisture Alarm & Trouble Alarm at Weld 2-AHH-2 on 12-inch Recirculation Piping Loop A.Caused by Logic Board Misinterpretation of Sensor Output | | | 05000278/LER-1983-022-03, /03L-0:on 831207,4 Kv Emergency Bus Undervoltage Relay IVA-127 Failed to Operate.Caused by Binding of Relay Rotating Disk Due to Dust Buildup.Relays Cleaned,Tested & Returned to Svc | /03L-0:on 831207,4 Kv Emergency Bus Undervoltage Relay IVA-127 Failed to Operate.Caused by Binding of Relay Rotating Disk Due to Dust Buildup.Relays Cleaned,Tested & Returned to Svc | | | 05000277/LER-1983-022-03, /03L-0:on 830907,recirculation Motor Generator Set Room & Recirculation Motor Generator Set Lube Oil Pump Room Sprinkler Sys Did Not Automatically Actuate.Caused by Coil Failure.Proper Dc Coils Installed | /03L-0:on 830907,recirculation Motor Generator Set Room & Recirculation Motor Generator Set Lube Oil Pump Room Sprinkler Sys Did Not Automatically Actuate.Caused by Coil Failure.Proper Dc Coils Installed | | | 05000278/LER-1983-023-03, /03L-0:on 831213,while Performing Routine Surveillance Test,Torus narrow-range Level Indicator Found Out of Calibr.Level Indicator Replaced,Calibr & Returned to Svc on 831216 | /03L-0:on 831213,while Performing Routine Surveillance Test,Torus narrow-range Level Indicator Found Out of Calibr.Level Indicator Replaced,Calibr & Returned to Svc on 831216 | | | 05000277/LER-1983-023-01, /01X-1:on 831108,combined Leakage for Type B & C Tests Exceeded 10CFR50,App J Limit & Containment Isolation Valves MO-2-74 & MO-23-57 Failed Local Leak Rate Test. Caused by Normal Wear of Valve Internals | /01X-1:on 831108,combined Leakage for Type B & C Tests Exceeded 10CFR50,App J Limit & Containment Isolation Valves MO-2-74 & MO-23-57 Failed Local Leak Rate Test. Caused by Normal Wear of Valve Internals | |
|