Finding | |
|---|---|
| Title | Licensee-Identified Violation |
| Description | Title 10 CFR 50, Appendix B, Criterion III, Design Control, requires measures be established for the selection and review for suitability of application of material, parts, equipment, and processes that are essential to the safety-related functions of the SSCs. Contrary to this requirement, the licensee identified that from 2009 until November 20, 2013, NSR parts were installed in safety-related components. During operating experience review, the licensee identified the potential for NSR parts, such as gaskets and packing to be installed in safety-related systems. The licensee conducted an evaluation from 2009 forward to determine the use of both soft and hard NSR parts in limited volume safety-related systems or other applications where it performs a safety-related function. Eight occurrences of soft NSR parts installed in limited volume safety-related systems (SBLC, diesel fuel oil, alternate nitrogen, and HPCI) were identified. Four occurrences of hard NSR parts installed in limited volume safety-related systems (alternate nitrogen, high pressure core spray, and RCIC) were identified. Lastly, seven occurrences were identified by the licensee where hard NSR parts (key, fuses, relay, seal kit, and sealant) were installed in other applications where it performs a safety-related function. The licensee entered this issue into its corrective action program, CAPs 1407369 and 1410037, and through evaluation has determined the safety-related components impacted by the use of NSR parts are operable but non-conforming. The licensee has established actions to replace the identified NSR parts. The inspectors determined that this issue was more than minor because, if left uncorrected, the installation of parts/materials which fail to meet requirements could lead to subsequent part failure and adverse impact the ability of safety-related equipment to perform its safety function. Specifically, the licensee failed to establish measures for the selection of parts that are essential to the safety-related functions of SSCs. As a result, the licensee installed NSR parts in safety-related systems. The inspectors determined that this issue was associated with the Mitigating Systems cornerstone and could be evaluated using the SDP. The inspectors used IMC 0609, Attachment 0609.04, Appendix A, Exhibit 2, Mitigating Systems Screening Questions, dated June 19, 2012, and concluded that this issue was of very low safety significance (Green) because the finding was associated with a deficiency that only affected the design or qualification of the specific SSCs. |
| Site: | Monticello |
|---|---|
| Report | IR 05000263/2014003 Section 4OA7 |
| Date counted | Jun 30, 2014 (2014Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Licensee-identified |
| Inspection Procedure: | |
| Inspectors (proximate) | K Riemer K Stoedter M Phalen P Laflamme P Voss P Zurawski |
| Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
| INPO aspect | |
| ' | |
Finding - Monticello - IR 05000263/2014003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Monticello) @ 2014Q2
Self-Identified List (Monticello)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||