IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERRDD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTTUUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISSRREEPPOORRTTRevision:17Table:9.8-2 Page:1 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATION1PLANT AIR SYSTEMPlant Air CompressorNumber2 (one for each unit)TypeCentrifugalDischarge Pressure, psig100Discharge Temperature (approximate)F266Capacity, icfm (with inlet conditions of 14.3 psia and 110oF)1,485Plant Air compressor AftercoolerNumber1 per compressorTypeShell & TubeTube Side Flow, icfm (air)1,500Shell Side Flow, gpm (water)23Shell Side Design Pressure, psig150Tube Side Design Pressure, psig150Shell MaterialCarbon SteelTube MaterialAdmiraltyDesign CodeASME B&PV Code Section VIIIPlant Air ReceiverNumber2 (one for each unit)Capacity, ft3200Design Pressure, psig125Design Temperature, F300Operating Pressure, psig100Operating Temperature, F105MaterialCarbon SteelDesign CodeASME B&PV Code Section VIII 1 The information in this Table reflects manufacturer equipment ratings and specifications for the compressed airsystems components. These values do not necessarily reflect design basis values for the compressed air systems.

IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERRDD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTTUUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISSRREEPPOORRTTRevision:17Table:9.8-2 Page:2 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATIONCONTROL AIR SYSTEMControl Air CompressorNumber2 (one for each unit)TypeReciprocatingNominal Discharge Pressure, psig100Discharge Temperature, F320Capacity, icfm338, @29.92 in HgA inlet, 480 RPM, 100 psigdischargeControl Air Compressor AftercoolerNumber1 per compressorTypeShell & TubeTube Side Flow, icfm(air)338Shell Side Flow, gpm (water)5Shell Side Design Pressure, psig150Tube Side Design Pressure, psig150Shell MaterialCarbon SteelTube MaterialAdmiraltyDesign CodeASME B&PV Code Section VIIIControl Air Receiver (Wet Control Air)Number2 (one for each unit)Capacity, ft3500Design Pressure, psig125Design Temperature, F300Operating Pressure, psig100Operating Temperature, F95MaterialCarbon SteelDesign CodeASME B&PV Code Section VIII IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERRDD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTTUUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISSRREEPPOORRTTRevision:17Table:9.8-2 Page:3 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATIONCONTROL AIR SYSTEM (CONT'D)Control Air PrefilterNumber4 (two for each unit in parallel strings)Capacity, scfm325Inlet pressure, psig100Inlet temperature, F (saturated)95Effluent Dewpoint F(at design pressure)-40Retention Size, microns5TypeAdsorbentControl Air DrierNumber8 (four for each unit in two parallel strings)Capacity, scfm325Dew Point at 100 psig, F-40TypeConvectionControl Air After FilterNumber4 (two for each unit in parallel)Capacity, scfm840Retention Size, microns4TypeAdsorbentControl Air Receiver (Dry Control Air)Number4 (two for each unit in parallel strings)Capacity, ft3500Design Pressure, psig125Design Temperature, F300Operating Pressure, psig100Operating Temperature, F105MaterialCarbon SteelDesign CodeASME B&PV Code Section VIII IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERRDD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTTUUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISSRREEPPOORRTTRevision:17Table:9.8-2 Page:4 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATIONCONTROL AIR SYSTEM (CONT'D)Backup Plant Air Compressor with Integral Skid Mounted Aircooled AftercoolerNumber1 (common for both units)TypeRotary ScrewNominal Discharge Pressure100Discharge Temperature (approximate)oF108Capacity, icfm (with inlet conditions of 14.5 psia and 80oF)668Backup Plant Air Compressor Air ReceiverNumber1Capacity, ft3100Design Pressure, psig150Design temperature, oF450Operating Pressure, psig100Operating Temperature, oF105MaterialCarbon SteelDesign CodeASME B & PV Code section VIII