July 16, 2007
SUBJECT:
SALEM AND HOPE CREEK GENERATING STATION - NRC PHYSICAL SECURITY BASELINE INSPECTION REPORT NOS. 05000272/2007402, 05000311/2007402, 05000354/2007402
Dear Mr. Levis:
On June 15, 2007, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your Salem and Hope Creek Generating Station. The inspection covered one or more of the key attributes of the security cornerstone of the NRCs Reactor Oversight Process. The enclosed report documents the inspection results, which were discussed on June 15, 2007, with Mr. Carl Fricker, Vice President Operations Support and other members of your staff.
The inspection examined activities conducted under your licenses as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your licenses. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.
No findings of significance were identified.
Warning: Violation of section 147 of the Atomic Energy Act, Safeguards Information is subject to civil and criminal penalties DETERMINATION MADE BY:
NAME/TITLE: James Trapp, Chief ORGANIZATION: RI/DRS/PSB1 BASIS: DG-SG-1:_(300) Physical Protection Program SIGNATURE_____/RA/_________ DATE:_07/11/07_ In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system, ADAMS. ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related information contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be available for public inspection.
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security-Related Information - Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390(b)(1).
Sincerely,
/RA/
James M. Trapp, Chief Plant Support Branch 1 Division of Reactor Safety Docket Nos.
50-272, 50-311, 50-354 License Nos. DPR-70, DPR-75, NPF-57 Enclosure:
Inspection Report Nos. 05000272/2007402, 05000311/2007402, and 05000354/2007402 w/Attachment : Supplemental Information (CONTAINS (SGI))