ML17040A257
Text
(Page 2 of
- 2)
~
NEWFAX 3/85 N58JIJ
~
Ill i
~
~ ri.>
C> a.
~
Z:::>
WV'I
~
z w
~
- z:
~
u I-h al QO CD
<(
"'1""...
- x:cn 0::
V>U"'I
<....>~ -
WO:::£-
a:: ow 0:: ~ a:: al -
w LL.
lJ....
CL-a:: co cn-o
_.... LO r-LL. :C:
cn--
l/)
........, __ <(
I W-"13"0 al CD LL. *t-a:l :r:
"'1""W VlOO I ~w WW::::EW::I:
- i:: w :.,.:'.'. l/)
ZU:X:<t-ULnU::::E 0-V")
-oc..:>
00 1-3 z: l.L.
Cl
<t:ZOV>
-LL......JLL.
0 z:-o Ill oa......... <
z I W t-::3=
8 r--a::oww Ill vo:::z:a-f'l"')W<t w
Ou_
OLt..J a:
I V> -:z: a:
f'l"')Z:l-<C 0<{.........,
0::
a:: _Jl/)Lt..J a::,_ a_ w Q._
u VH-w..
C).
w
- ZLL.
0::.1- <...'.)
w l.LJ <t 3= _J a:
0....C)C)_J a_
<(.
00 ::J a:::
C) co wa:=i=
- O....WO I z:
a:l w <( 0::. L.()
Vt..!)VO
- ~l.L.J I
- :::C WI-w C) (./) a:: 0 0
- z::
- z *oc:o Ul'--l-"'1'"t-00 I..{) al :r: w
- 0""'" V")O::
u I
a:::
Z:f'l"'):X:OO
.-.OV>t-U w...
Cl 0
Li>
g A
B c
NOT A SCHEDULED CABLE SEE DWG'S. E-970 & E-971 I
I 1
R, G, WO I C
TRl, TRll, CL!,
CLI I, R. G. WO I OS 2 T OS OPEN 33 00 CO CQ9 I >-----t 1-------t JM XA XB 7
~
8 §
. FU FU
<GA)
I GA>
STOP STOP ------------
1N 33 E
G>-cL CL2 bc 42 c
T"ll
_J f
~cl2---t---ul!
L:----TI121--.rSE 1~:""'
CL21 15 OPEfl 12 ~
l :
~ :fil'-.
~(
9~ cof TR21 8
E I ~I CL21 9
TRE OS 14 -
'1 ! I cof CL21 B
Vll 10-CD ftCL_J ~ I 3
OS TRI I CAI 0 I A
CD JT '(
I ~ j CLI I
~+/-11 JT?
CS CLI I
~t OPEN
£ i CS 7kI CLOSE
- TRt JT?
TR C:TtRI OS JT:it'.
B.
B rn CD TR -
16 4~1 4
OS
£Q L CL-+--*O 24 Q.B
- ...l_-420 2s6~
INDICATION I
I I
I I
I I
I I
I I
ED 7489 NOTES:
~
(j. DELETED :
- 2. FOR GENERAL NOTES SEE DRAWING INDEX E-448.
- 3. FOR LOCAL PUSHBUTTONS AND INDICATING LIGHTS DETAILS SEE DWG. E-308, SH. 7, TYPES 3, 4 ~ 6.
- 4. FOR DETAILS OF CS SEE DWG. E-306, SH.-7, FIG. 7.
- 5. FOR VALVE LIMIT SW. DEVELOPMENT SEE DRAWING NO. E -3 OB SH. BF
- F I G. K.
1 5
- 6. FOR DETAILS OF OS SEE OWG. E-308, SH.
FIG. I (8E1159l.
- 1. DELETED
- 8. DELETED
- 9. OVERLOAD HEATERS REPLACED BY SHORTING BARS.
- 10. FIELD TO ADJUST ROTOR 3 WITH SWITCH CONTACTS 9 THRU 12 TO ACTUATE WHEN VALVE REACHES 20/.
1+51.,-0/.) OPEN *
- 11. ADD LOCAL CONTROL SWITCH GUARD ASSEMBLY PER E-302A SH. 185A ~ B TO SWITCH NV06010,NV6120.
- 13. FOR SFRCS BLOCK SWITCH ANO SCHEMATIC SEE SF-0038 SH. 25.
- 14. RELAYS 42-XO AND 42-XC ARE BOTH WESTINGHOUSE TYPE AR440AR*----------~
IZS612l
~
13 bMu(; b M
SU TEST PNL PT. 101
([-j79) 8 titL CZ674J VALVE LIMIT SWITCH AUX. CONTACTS THIS DRAWING WAS REDRAWN ON CAD ANO SUPERCEDES REVISION 9 SCALE NONE DESIGNED DRAWN RRD DATE 06-06-89 DAVIS-BESSE NUCLEAR POWER STATION I
I TH~!!!! E0~,2 °cOMPlNY Q
ELEMENTARY WIRING DIAGRAMS FEEOWATER SYSTEM~.f.A MN FW 1 STOP ~-
5 ----r-----t DRAWING NO.
REV.
E-448 SH.4A 15 OB 4-12-04 DFN= f :/SCHEME/C44BS4A.DGN