IR 05000272/1980030
| ML18086A616 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 01/23/1981 |
| From: | Bailey R, Devlin J, Mckeown L NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | |
| Shared Package | |
| ML18086A611 | List: |
| References | |
| 50-272-80-30, 50-311-80-21, NUDOCS 8106040081 | |
| Download: ML18086A616 (2) | |
Text
U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT
REGION I
- 50-272/80-30 Report No.-:; :S0-311/80-21
-
50-272 Docket No.;,. *:
50-311 License N DPR-70 DPR-75 Safeguards Group __
I_V_
Licensee:
Public Service Electric and Gas Company 80 Park Plaza Newark, New Jersey 07101 Facility Name:
Salem Nuclear Generating Station, Units 1 and 2 Inspection At:
Hancocks Bridge, New Jersey Inspection Conducted:
November 17-21, 1980 Date of Last Physical Security Inspection Visit:
July 14-18, 1980 Type of Inspecti Security 1-l-c!:1 -RO date
/-II/- 'l</
Lisa M. McKeown, Physical Security Inspe~tor date date 1 /2s. /?1 Approved by~~c~~~
Investigation I date'
'
- ( James W. Devlin, Chief, Security and
~Section, Safeguards Branch Inspection Summary:
Ins ection on November 17-21, Nos. 50-272/80-30 and 50-311/80-21 1980 Combined Ins ection Re ort Areas* Inspected: Implementation and compliance with the accepted physical security*
plan relative to the Security Program Audit, Security Organization, Physical Barriers (PA)(VA), Lighting, Access Controls, (Identification), (Search), (Escorting), and (Vital Areas)~ Alarm Stations, Detection Afds, Assess.ment Aids, Corrununications, Test-ing and Maintenance, Compensatory Measures, Power Supply, Response, Locks, Keys and Combinations and Records and Reports, I&E Bulletin 79-16, and I&E Circular 80-0 Followup on licensee action on previously identified items of noncompliance related to physical.security. The inspection involved 68 inspector-hours onsite by two NRC regional ~a~ed inspectors and commenced during regular hour *
Results: The licensee was found to be in compliance with NRC requirements within 21 areas examined during the inspection except *for the following seven items:
Region I Form 167 (August 1979)
Security Organization - Failure to equip all security force members with corranuni-cations; EhY-sical Barriers (PA) - Failure to maintain the isolation zones free of structures _and materials; Access Control - [Identification) - Failure to collect all photo~ ~dentification badges; Access Control (_Vital Area) - Failure to control access to:-V3tal Area; Access Control (_Authorization) - Failure to have a bullet resistant enclosure for the last person who grants access to the Protected Area; Records - Failure to document the test of detection aids; and Access Control -
Failure to record the name, badge number, time and date of entry and reason for entry to Vital Areas *
r