ML22060A092

From kanterella
Revision as of 10:45, 2 September 2023 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Louisiana Energy Services, LLC, Dba Urenco USA, Semi-Annual Radiological Effluent Release Report for July 1, 2021 Through December 31 2021
ML22060A092
Person / Time
Site: 07003103
Issue date: 02/25/2022
From: Padgett W
Louisiana Energy Services, URENCO USA
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
LES-22-046-NRC
Download: ML22060A092 (10)


Text

LES-22-046-N RC USA The National 2/25/22 Enrichment Facility ATTN : Document Control Desk Director Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington , D.C. 20555-0001 Louisiana Energy Services, LLC NRC Docket No. 70-3103

Subject:

Semi-Annual Radiological Effluent Release Report for July 1, 2021 through December 31 , 2021 Pursuant to 10 CFR 70.59 , Louisiana Energy Services, LLC , also dba URENCO USA, herewith submits the subject report. Enclosure 1 specifies the quantities released of licensed principal radionuclides in liquid or gaseous form , to uncontrolled areas.

Should there be any questions regard ing this submittal, please contact Barry Love, Licensing Specialist at 575-394-4482.

Respectfully, Digita lly signed by Wyatt  ; Wyatt Padgett Date: 2022.02.25 Padgett /, 13:27:39 -07'00' Wyatt Padgett Compliance Manager

Enclosure:

1. Semi-Annual Radiological Effluent Release Report for July 1, 2021 through December 31 , 2021 Louisiana Energy Services, LLC UUSA I P.O. Box 1789 I Eunice I New Mexico I 88231 I USA T: +1 (575) 394 4646 I W : www.uusa.urenco.com CCI 2022 Louisiana Energy Services, LLC 1

LES-22-046-N RC USA The National Enrichment Facility CC:

USNRC Region II RidsRgn2MailCenter@nrc.gov Matthew Bartlett, Project Manager - UUSA U.S. Nuclear Regulatory Commission Matthew. Bartlett@nrc.gov Louisiana Energy Services, LLC UUSA I P.O. Box 1789 I Eunice I New Mexico I 8823 1 I USA T: +1 (575) 394 4646 I W : www.uusa.urenco.com

<<:> 2022 Louisiana Energy Services, LLC 2

LES-22-046-NRC USA The National Enrichment Facility ENCLOSURE 1 Semi-Annual Radiological Effluent Release Report for July 1, 2021 through December 31 , 2021 Louisiana Energy Services, LLC UUSA I P.O. Box 1789 / Eunice I New Mexico / 88231 I USA T: +1 (575) 394 4646 / W : www.uusa.urenco.com

~ 2022 Louisiana Energy Services, LLC 1

URENCO USA: Report of Radioactivity in Effluents: Liquid & Air: July 2021 - December 2021 There were no releases to the public during the reporting period that exceeded regulatory requirements, and detected isotopic uranium activities were comparable to pre-operational activities. No dose assessment was performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points were acceptable. The potential maximum doses directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentration dose.

In liquid effluent, the concentrations of isotopic uranium were either below the Minimum Detectable Concentration (MDC) or less than 10% of values listed in 10 CFR 20, Appendix B, Table 3, "Releases to Sewers" (Table 1-1).

In gaseous effluent, the gross uranium activity was either below the Minimum Detectable Activity (MDA) or less than 10%

of values listed in 1 0 CFR 20, Appendix B, Table 2, "Effluent Concentrations - Class D Air" for U234, U235, and U238.

The concentrations of isotopic uranium in gaseous effluent was either below the Minimum Detectable Concentration (MDC) or less than 10% of values listed in 10 CFR 20.1301, 10 CFR 20.1302, and 10 CFR 20.1101 (d}, as described in NRC Regulatory Guide 4.20 "Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors" Revision 1 dated April 2012.

Sampling data was not reported for gross alpha and gross beta for Quarter 3, 2021 due to a software error. The data will be reported on an amended SARERR.

LIST OF TABLES Table No. Title 1-1 Lift Station 1 Wastewater Effluent - Radionuclides Quarter 3 & 4 , 2021 1-2 Separations Building Module-1001 (SBM 1001) Pumped Extract Exhaust Gaseous Effluent Vent System ,

1001-562-1 MA 1 & 1001-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4 , 2021 1-3 Separations Building Module-1003 (SBM 1003) Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1 MA1 & 1003-562-1MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4 , 2021 1-4 Separations Building Module-1005 (SBM 1005) Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 & 1005-562-1MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3 & 4, 2021 1-5 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Local Extract Exhaust Gaseous Effluent Vent System , 1100-562-1 MA1 & 1100-562-1 MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3

& 4 , 2021 1-6 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100) Fume Hood Exhaust Gaseous Effluent Vent System , 1100-562-2MA 1 & 1100-562-2MA2 - Gross Alpha & Gross Beta, and Radionuclides Quarters 3

& 4 , 2021

TABLE 1-1 Lift Station 1 Wastewater Effluent- Radionuclides, Quarters 3 & 4, 2021 URENCO USA Lea County, New Mexico Lift Station 1 - July - December 2021 Result Uranium - 233/234 2.00E-11 9.00E-11 13,000 Below LLD Result Below LLD 10/11/21 07/01/21 - Result Uranium - 235/236 183 0.00E+00 0945 12/31/21 0.00E+00 13,000 Below LLD Result Below LLD Result Uranium - 238 2.00E-11 7.00E-11 13,000 Below LLD Result Below LLD Lift Station 1 Duplicate - July - December 2021 2.00E-11 Result 1.00E-10 13000 Below LLD 'Result Below LL[) .,

Ui'anfum ~ 2351238 10/11/21 07/01/21 -

0.00E+00 Result 183 0945 12/31/21 0.00E+00 13,000 BelowLLD Result Below LLD Result Uranium - 238 7.00E-11 2.00E-11 13,000 BelowLLD Result Below LLD Notes:

1. * =Table 3.4-4 'Anticipated Normal Plant Water Consumption" from the Environmental Report, Rev. 19, lists "Total Personnel Water Use" as approximately 13,000 gallons per day.
2. µCi/ml= microCuries per milliliter.
3. Radionuclides analyzed using method EICHROM AC01 by Cardinal Laboratories of Hobbs , NM .
4. Quantity released is calculated if the result equals or exceeds the LLD. Facility-required lower level of detection (LLD) is 3.09E-9 µCi/ml.

TABLE 1-2 Separations Building Module-1001 (SBM 1001 ): Pumped Extract Exhaust Gaseous Effluent Vent System , 1001-562-1 MA 1 & 1001-562-1MA2 Gross Alpha & Beta: Quarter 4 , and Radionuclides: Quarters 3 & 4 , 2021 URENCO USA Lea County, New Mexico.

1001 -562-1MA1 10015621MA1100421 11/02/21 10/4/21 - 11/2/21 0.00E+00 6.35E-16 1.40E-07 3.72E+05 <MDA <MDA Gross 10015621MA1110221 12/07/21 11/2/21 - 12/7/21 0.00E+00 5.36E-16 1.40E-07 4 .39E+05 <MDA <MDA Alpha 10015621MA1 120721 01/03/22 12/7/21 - 01/3/22 -7.59E-17 6.88E-16 1.22E-07 3.21E+05 <MDA <MDA 10015621MA1 100421 11/02/21 10/4/21 - 11/2/21 4.40E-15 5.12E-15 1.90E-06 3.72E+05 <MDA <MDA Gross 10015621MA1110221 12/07/21 11/2/21 - 12/7/21 2.57E-15 4 .32E-15 1.66E-06 4.39E+05 <MDA <MDA Beta 10015621MA1 120721 01/03/22 12/7/21 - 01/3/22 3.31E-15 5.55E-15 1.66E-06 3.21E+05 <MDA <MDA 1001-562-1 MA2 10015621MA2 100120 11/4/20 10/1/20 - 11/4/20 -1 .30E-16 6.06E-16 9.91E-08 3.54E+05 <MDA <MDA 10015621MA2110420 12/01/20 11/4/20-12/1/20 Gross -1.20E-16 5.59E-16 Alpha 9 91E-08 2.44E+05 <MDA <MDA 10015621MA2 120120 01/04/21 12/1/20 - 1/4/21 2.49E-16 7.68E-16 1.85E-07 3.21 E+05 <MDA <MDA 10015621MA2 100120 11/4/20 10/1/20 - 11/4/20 5.33E-15 4 .88E-15 1.85E-06 3.54E+05 1.89E-09 0.18%

Gross 10015621 MA2 110420 12/01/20 11 /4/20 - 12/1 /20 3.80E-15 4 .50E-15 1.76E-06 2.44E+05 <MDA <MDA Beta 10015621MA2 120120 01/04/21 12/1/20 - 1/4/21 5.85E-15 6.19E-15 1.80E-06 3.21E+05 <MDA <MDA U-233/234 1.11E-16 1.10E-16 1.1 0E-16 1.30E-16 <MDC <MDC U- 235/236 4 Qtr 1/3/2022 10/4/21-1/3/22 8.10E-17 1.05E-16 1.05E-16 1.46E-16 7.63E+05 <MDC <MDC U-238 2.21E-16 1.55E-16 1.56E-16 1.47E-16 0.00 0.007%

Notes: Stack filter discrepancy noted on 120721 between 1001-562-1 MA 1 & 1001-562-1 MA2 at -50%.

TABLE 1-3

Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System , 1003-562-1MA1 &

1003-562-1 MA2 Gross Alpha & Beta : Quarter 4 , and Radionuclides: Quarters 3 & 4 , 2021 UREN CO USA Lea County, New Mexico 1003-562-1 MA1 10035621 MA 1 100421 11/02/21 10/4/21 - 11/2/21 -6.50E-17 5.89E-16 1.22E-07 1.54E+07 <MDA <MDA Gross 10035621 MA 1 110221 12/07/21 11/2/21 - 12/7/21 -1 .02E-1 6 4.77E-16 9.91 E-08 1.90E+07 <MDA <MDA Alpha 10035621MA1 120721 01/03/22 12/7/21 - 1/3/22 1.51E-16 7.04E-16 1.71 E-07 1.46E+07 <MDA <MDA 10035621 MA 1 100421 11/02/21 10/4/21 - 11/2/21 4 .01E-15 4.75E-15 1.76E-06 1.54E+07 <MDA <MDA Gross 10035621MA1 110221 12/07/21 11/2/21 - 12/7/21 3.25E-15 4.77E-16 1.76E-06 1.90E+07 1.75E-09 0.108%

Beta 10035621MA1 120721 01/03/22 12/7/21 - 1/3/22 5.92E-15 5.67E-15 1.83E-06 1.46E+07 2.44E-09 0.20%

1003-562-1 MA2 10035621MA2 100421 11/02/21 10/4/21 - 11/2/21 -6.61 E-17 6.00E-16 1.22E-07 4.71E+05 <MDA <MDA Gross 10035621 MA2 110221 12/07/21 11/2/21 - 12/7/21 0.00E+00 4.95E-16 1.40E-07 5.84E+05 <MDA <MDA Alpha 10035621MA2 120721 01/03/22 12/7/21 - 1/3/22 -1 .33E-1 6 6.23E-16 9.91 E-08 4.50E+05 <MDA <MDA 10035621 MA2 100421 11/02/21 10/4/21 - 11/2/21 3.61E-15 4.83E-15 1.72E-06 4.71E+05 <MDA <MDA Gross 10035621 MA2 110221 12/07/21 11/2/21 - 12/7/21 4.36E-15 4.95E-16 1.85E-06 5.84E+05 2.55E-09 0.145%

Beta 10035621MA2 120721 01/03/22 12m21 - 113122 1.74E-15 5.02E-15 1.55E-06 4.50E+05 <MDA <MDA 1003-562-1 MA1 IJ..233fl34 2.00E-16 1.68E-16 1.69E-16 1.94E-16 0.00 0.007%

IJ,. 10/4/2021 7/1/21-10/4/21 1.78E-17 7.41E-17 7.41E-17 1.90E-16 1.47E+06 <MDC <MDC IJ,. 1.90E-16 1.56E-16 1.56E-16 1.54E-16 0.00 0.006%

U-2 4 1.14E-16 9.55E-1 7 9.58E-17 8.17E-17 0.00 0.004%

U- 235/236 4 Qtr 1/3/2022 10/4/21 -1/3/22 0.00E+00 6.70E-17 6.70E-17 1.45E-16 1.39E+06 <MDC <MDC U-238 1.30E-16 1.03E-16 1.03E-16 9.32E-17 0.00 0.004%

1003-562-1 MA2 lJ..23312,34 1.55E-16 1.02E-16 1.03E-16 9.28E-17 0.00 0.005%

U-2351236 3Qtr. 10/4/2021 7/1/21 -10/4/21 O.OOE+OO 5.29E-17 5.29E-17 1.14E-16 1.59E+06 <MDC <MDC IJ..238 1.21E-16 8.68E-17 8.72E-17 6.43E-17 0.00 0.004%

U-233/234 8.20E-17 6.16E-17 6.19E-17 5.74E-17 0.00 0.003%

U- 235/236 4 Qtr 1/3/2022 10/4/21-1 /3/22 4.05E-17 5.31 E-17 5.32E-17 8.09E-17 1.51E+06 <MDC <MDC U-238 5.80E-17 5.32E- 17 5.33E-17 6.15E-17 <MDC <MDC Notes: None TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1 MA 1 &

1005-562-1MA2 Gross Alpha & Beta : Quarter 4, and Radionuclides : Quarters 3 & 4, 2021 URENCO USA Lea County, New Mexico 1005-562-1MA1 10055621MA1 100421 01/03/22 10/4/21 - 1/3/22 Gross -2 .20E-17 2.00E-16 Al ha 1.22E-07 2.81E+06 <MDA <MDA 10055621MA1 100421 01/03/22 10/4/21 - 1/3/22 Gross 1.92E-15 1.61E-15 1.89E-06 Beta 2.81E+06 5.40E-09 0.064%

1005-562-1MA2 10055621MA2 100421 11/02/21 10/4/21 - 11/2/21 0.00E+00 1.37E-15 1.40E-07 3.94E+05 <MDA <MDA 10055621 MA2 110221 12/07/21 11/2/21 - 12/7/21 Gross -1.67E-16 5.07E-16 9.91E-08 1.04E+06 Alpha <MDA <MDA 10055621MA2 120721 01/03/22 12/7/21 - 1/3/22 2.19E-16 6.76E-16 1.85E-07 8.09E+05 <MDA <MDA 10055621 MA2 100421 11/02/21 10/4/21 - 11/2/21 7.15E-15 1.10E-14 1.68E-06 3.94E+05 <MDA <MDA 10055621MA2110221 Gross 12/07/21 11/2/21 - 12/7/21 4.11E-15 4.09E-15 1.95E-06 1.04E+06 4.26E-09 0.137%

Beta 10055621 MA2 120721 01/03/22 12m21 - 113122 5.96E-15 5.45E-15 1.85E-06 8.09E+05 4.82E-09 0.199%

1.53E-16 1.16E-16 1.16E-16 1.07E-16 10/4/2021 7/1/20-10/4/21 5.04E-17 8.57E-17 8.58E-17 1.51E-16 lJ.. 1.96E-16 1.29E-16 1.30E-16 9.72E-17 U-233/234 4.12E-17 4.54E-17 4.55E-17 6.18E-17 <MDC <MDC U- 235/236 4Qtr. 1/3/2022 10/4/21-1/3/22 2.33E-17 3.56E-17 3.56E-17 5.31E-17 2.81E+06 <MDC <MDC U-238 4.96E-17 4.54E-17 4.55E-17 4.28E-17 0.00 0.002%

1005-562-1 MA2 7.99~;1;7 8.01E~17 1.17~ti6 3.67E-17 3.67E-17 noe:11 9.86E-17 9.93E-17 6.22E-17 U-233/234 1.58E-16 1.01 E-16 1.02E-16 6.73E-17 0.00 0.005%

U-235/236 4 Qtr 1/3/2022 10/4/21-1/3/22 5.97E-17 7.82E-17 7.83E-17 1.19E-16 2.24E+06 <MDC <MDC U-238 9.09E-17 7.80E-17 7.82E-17 7.67E-17 0.00 0.003%

Notes: 1005-562-1 MA 1 filter not pulled in October and November 2021 due to redundant monitor displaying locked in alarm on panel.

TABLE 1-5 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System , 1100-562-1 MA 1 &

1100-562-1 MA2, Gross Alpha & Beta: Quarter 4 , and Radionuclides: Quarters 3 & 4, 2021 URE NCO USA Lea County, New Mexico

1100-562-1MA1 11005621 MA 1 100421 11/02/21 10/4/21 - 11/2/21 -6.93E-17 6.29E-16 1.22E-07 2.44E+07 <MDA <MDA Gross 11005621 MA1 110221 12/07/21 11/2/21 - 12/7/21 6.64E-16 1.03E-15 2.21E-07 1.89E+07 <MDA <MDA Alpha 11005621MA1120721 01/03/22 12/7/21 - 1/3/22 -1 .19E-16 5.54E-16 9.91E-08 3.42E+07 <MDA <MDA 11005621 MA1 100421 11/02/21 10/4/21 - 11/2/21 2.77E-15 6.29E-16 1.64E-06 6.91E+05 1.91 E-09 0.092%

Gross 11005621 MA1 110221 12/07/21 11/2/21 - 12/7/21 1.32E-14 1.03E-15 2.03E-06 5.36E+05 7.05E-09 0.439%

Beta 11005621MA1120721 01/03/22 12/7/21 - 1/3/22 3.55E-15 4.47E-15 1.74E-06 9.70E+05 <MDA <MDA 1100-562-1MA2 11005621 MA2 100421 11/02/21 10/4/21 - 11/2/21 0.00E+0 6.00E-1 6 1.40E-07 9.96E+05 <MDA <MDA 11005621MA2110221 Gross -3.02E-17 12/07/21 11/2/21 - 12/7/21 4.99E-16 1.40E-07 1.20E+06 <MDA <MDA Alpha 11005621 MA2 120721 01/03/22 12/7/21 - 1/3/22 7.07E-17 6.41 E-16 1.58E-07 9.11 E+05 <MDA <MDA 11005621 MA2 100421 11/02/21 10/4/21 - 11/2/21 6.0 1E-15 4.83E-15 1.91 E-06 9.96E+05 5.99E-09 0.200%

Gross 11005621 MA2 110221 12/07/21 11/2/21 - 12/7/21 5.79E-15 4.99E-16 2.08E-06 1.20E+06 6.95E-09 0.193%

Beta 11005621MA2 120721 01/03/22 12/7/21 - 1/3/22 5.39E-15 5.17E-15 1.83E-06 9.11 E+05 4.91 E-09 0.180%

1100-562-1MA1 U-2331234 1.02E-16 8.52E-17 8.55E-17 9.90E-17 0.00 0.003%

U-2351236 3Qtr. 10/4/2021 7/1/21-10/4/21 1.85E-17 5.15E-17 5.15E-17 1.11E-16 3.26E+6 <MDC <MDC U-238 1.42E-16 9.46E-17 9.52E-17 7.86E-17 0.00 0.005%

U-233/234 1.83E-16 1.27E-16 1.28E-16 1.01 E-16 0.00 0.006%

U- 235/236 4 Qtr. 1/3/2022 10/4/21-1 /3/22 2.61E-17 7.25E-17 7.25E-17 1.57E-16 2.20 E+6 <MDC <MDC U-238 1.54E-16 1.19E-16 1.20E-16 1.19E-16 0.00 0.005%

1100-562-1 MA2 U-2331234 1.85E- 16 1.26E-16 1.27E-16 8.74E-17 0.00 0.006%

U-~36 3Qtr. 10/4/2021 7/1121-10/4/21 4.29E-17 7.29E-17 7.29E-17 1.23E-16 3 .17E+6 <MDC <MDC U-238 2.40E-17 5.99E-17 6.00E-17 1.25E-16 <MDC <MDC U-233/234 5.06E- 17 4.89E-17 4.90E-17 6.07E-17 <MDC <MDC U- 235/236 4Qtr. 1/3/2022 10/4/21-1 /3/22 0.00E+00 3.46E-17 3.46E-17 7.49E-17 3.11E+6 <MDC <MDC U-238 1.21E-16 7.23E-17 7.28E-17 6.04E-17 0.00 0.004%

Notes: Stack volume for 1100-562-1 MA 1 was not displaying on 090121 sample; TABLE 1-6 Container Receipt and Dispatch Building-1100 (SBM 1100): Local Extract Exhaust Gaseous Effluent Vent System , 1100-562-2MA1 &

1100-562-2MA2, Gross Alpha & Beta: Quarter 4, and Radionuclides: Quarters 3 & 4 , 2021 URENCO USA Lea County, New Mexico

1100-562-2MA1 11005622MA1 100421 11/02/21 10/4/21- 11/2/21 7.98E-17 2.06E-16 1.58E-07 2.24E+07 <MDA <MDA Gross 11005622MA1 110221 12/07/21 11/2/21 - 12/7/21 Alpha 2.17E-13 4.99E-13 1.98E-07 3.48E+07 <MDA <MDA 11005622MA1 120721 01/03/22 12/7/21 - 1/3/22 -2.02E-16 6.11E-16 9.91E-08 2.71E+07 <MDA <MDA 11005622MA1 100421 11/02/21 10/4/21- 11/2/21 4.24E-15 2.06E-16 1.78E-06 2.24E+07 9.50E-08 0.141%

Gross 11005622MA1 110221 12/07/21 11/2/21 - 12/7/21 5.20E-12 4.99E-13 1.92E-06 3.48E+07 1.81E-07 0.173%

Beta 11005622MA1 120721 01/03/22 12/7/21 - 1/3/22 2.99E-15 4.93E-15 1.81 E-06 2.71E+07 <MDA <MDA 1100-562-2MA2 11005622MA2 100421 11/02/21 10/4/21 - 11/2/21 9.86E-17 8.95E-16 1.58E-07 3.03E+07 <MDA <MDA 11005622MA2 110221 Gross 12/07/21 11/2/21 - 12/7/21 0.00E+00 7.09E-16 1.40E-07 3.64E+07 <MDA <MDA Alpha 11005622MA2120721 01/03/22 12/7/21 - 1/3/22 4.06E-17 8.63E-16 1.58E-07 2.81E+07 <MDA <MDA 11005622MA2 100421 11/02/21 10/4/21 - 11/2/21 1.10E-14 7.21E-15 2.07E-06 3.03E+07 3.33E-07 0.367%

Gross 11005622MA2 11 0221 12/07/21 11/2/21 - 12/7/21 5.68E-15 7.09E-16 1.82E-06 3.64E+07 2.07E-07 0.189%

Beta 11005622MA2 120721 01/03/22 12/7/21 - 1/3/22 1.04E-14 6.95E-15 2.10E-06 2.81E+07 2.91E-07 0.345%

1.80E-16 1.10E-16 1.10E-16 0.00 0.006%

3Qtr. 10/4/2021 7/1/21-10/4/21 4.69E-17 6.73E-17 6.74E-17 1.10E-16 9.26E+07 <MDC <MOC 8.95E-17 7.65E-17 7.67E-17 9.24E-1 <MOC <MOC U-233/234 1.24E-16 9.58E-17 9.62E-17 1.05E-16 0.00 0.004%

U- 235/236 4 Qtr. 1/3/2022 10/4/21-1 /3/22 9.62E-18 4.01 E-17 4.01E-17 1.03E-16 8.43E+07 <MDC <MDC U-238 1.03E-16 8.36E-17 8.39E- 17 8.32E-17 0. 00 0.003%

11 00-562-2MA2 (1-2331234 5.32E-16 2.02E-16 2.06E-16 1.12E-16 0.00 0.018%

U--236.1236 3Qtr. 10/4/2021 7/1/21-10/4/21 8.38E-17 8.66E-17 8.68E-17 9.14E-17 9.99E+07 <MOC <MDC 1--....;.;.::=-1--......;=.;;_--1 U-238 2.80E-16 1.42E-16 1.43E-16 7.37E-17 0.00 0.009%

U-233/234 3.10E-16 1.52E-1 6 1.53E-16 7.69E-17 0.00 0.010%

U- 235/236 4 Qtr. 1/3/2022 10/4/21-1 /3/22 6.44E-17 7.78E-17 7.79E-17 9.49E-1 7 9.48E+07 <MDC <MDC l------"'=-=-1---"-=-=------l U-238 2.44E-16 1.37E-16 1.38E-16 1.04E-1 6 0.00 0.008%

Notes: None

1. Ci = Curies
2. µCi/ml = micro-Curies per milliliter.
3. m* = cubic meters.
4. MDA = minimum detectable activity.
5. MDC= minimum detectable concentration.
6. Quantity released is calculated if the result Equals or Exceeds MDA or MDC.
7. Radionuclides analyzed using Procedure EPA 908.0 Modified by Eberline Analytical Corp of Oak Ridge , TN .
8. Gross alpha and beta analyzed by URENCO USA per procedure EN-3-3030-01.