05000456/FIN-2013003-01
From kanterella
Revision as of 19:48, 20 February 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Finding | |
|---|---|
| Title | Failure to Identify and Correct Degraded DOST Room Sump Pump Discharge Check Valves |
| Description | The inspectors identified a finding of very low safety significance when licensee personnel failed to identify degraded Diesel Oil Storage Tank (DOST) room sump discharge check valves in 2013 and after performing periodic testing in 2005. The licensee entered this issue into their Corrective Action Program (CAP) as Issue Report (IR) 1526652, IR Not Generated as Required 2005 OD Check Valve UT [Ultrasonic Testing] Results. Corrective actions included the repair of the degraded DOST room sump check valves. The inspectors determined that the failure to identify issues associated with degraded DOST room sump pump discharge check valves was a performance deficiency. The inspectors determined that the performance deficiency was more than minor because it was associated with the Protection Against External Factors attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Since the finding resulted in the potential for a loss of the emergency power function during a turbine building flooding event, and based upon an actual DOST room sump check valve failure, a detailed risk evaluation was performed, which determined that the finding was of very low safety significance. This finding had a cross-cutting aspect in the Corrective Action Program component of the Problem Identification and Resolution (PI&R) cross-cutting area because the licensee failed to take appropriate corrective actions in a timely manner to address degraded DOST room sump check valves. |
| Site: | Braidwood |
|---|---|
| Report | IR 05000456/2013003 Section 1R06 |
| Date counted | Jun 30, 2013 (2013Q2) |
| Type: | Finding: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.06 |
| Inspectors (proximate) | M Learn M Perry N Feliz Adorno R Edwards R Ng T Daun T Go V Meghani A Dahbur A Dunlop A Garmoe A Sallman E Duncan J Benjamin J Neurauter J Robbins |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Braidwood - IR 05000456/2013003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2013Q2
Self-Identified List (Braidwood)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||