ML20204F211
| ML20204F211 | |
| Person / Time | |
|---|---|
| Site: | Washington State University |
| Issue date: | 07/16/1986 |
| From: | Wilson W WASHINGTON STATE UNIV., PULLMAN, WA |
| To: | Jonathan Montgomery NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| Shared Package | |
| ML20204F199 | List: |
| References | |
| NUDOCS 8608040124 | |
| Download: ML20204F211 (1) | |
Text
'
W 4QEb Washington State University ey gg Nuclear Radiation Center, Pullman, Washington 99164-1300 / 509-335-8641
%ll . .
July 16, 1986 James L. Montgomery, Chief Nuclear Materials Safety and Safeguards Branch U.S. Nuclear Regulatory Commission, Region V 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596 Re: Docket No.50-027
Dear Mr. Montgomery:
In response to the Notice of Violation of July 9,1986 relating to the type of lock used on the Security Storage Container at the WSU reactor facility, the following information is provided:
- 1. The corrective action taken was to obtain and install a Sargent and Greenleaf Inc. changeable combination padlock, federal specification FF-P-110 of 1985, lock type 8077A CLl/CL2. This lock is the only GSA approved lock 'for use on Security Storage Containers.
- 2. Use of the lock mentioned above will avoid further violations.
- 3. The above-mentioned lock was installed on June 24, 1986 achieving full compliance before the notice of violation was officially transmitted to the facility.
Sincerely, WfW&
W.E. Wilson Associate Director WEW:mb 8600040124 860730 l PDR ADOCK 05000027 C PDR
-