ML20090B488

From kanterella
Revision as of 06:50, 13 May 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Emergency Response Data Sys (ERDS) Communications Description & Survey Questionnaire & ERDS Data Point Library Per 911025 Ltr & NUREG-1394,Rev 1, ERDS Implementation, Respectively
ML20090B488
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 02/28/1992
From: Woodard J
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-NUREG-1394 NUDOCS 9203030430
Download: ML20090B488 (148)


Text

.

Soutnem Nuc ear Operating Compaw Post Othee Bos 1295 Berrnngham, Alabama 35201 Telechone 205 BOS 5086 m

um. Southem Nudear Operating Company vee Prescent rtre mothern electr c system Faty Proiwt February 28, 1992 Docket Nos. 50-348 50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Joseph M. Farley Nuclear Plant ._

Emeroency Resoonse Data System Gentlemen:

By letter dated October 25, 1991, Alabama Power Company submitted a proposed implementation plan and schedule in response to 10 CFR Part 50, Appendix E, Section VI, " Emergency Response Data System (ERDS)." In this letter a commitment was made to provide by March 1, 1992 the questionnaire identifying the Plant Attribute List, Enclosure 1, and Data Point Library, Enclosure 2, in accordance with NUREG-1394, Revision 1, " Emergency Response Data System (ERDS) Implementation." {

Therefore, Southern Nuclear Operating Company provides as Enclosure 1 a completed ERDS Communications Description and Survey Questionnaire which includes the Plant Attribute Librarv. In addition, provided as Enclosure 2 are the Data Point Library and accompanying Reference Files for each proposed parameter.

Southern Nuclear Operating Company requests a copy of the data -

communication software program developed by NUS Corporation for the NRC in order to facilitate proper data transmission to the NRC's ERDS mainframe computer from Farley Nuclear Plant.

If there are any questions, please advise.

Respectfully submitted,

,d b m NJ. Woodard JDW/BHW: map 1989 Enclosures cc: Mr. S. D. Ebneter Mr. S. T. Hoffman Mr. G. F. Maxwell i

'~

G s'.t") $ d A) 9203030430 920228 1 I

ADOCK 05000348

{DR PDR l

ENCLOSURE 1 1

- ERDS Comunications Description and Survey Questionnaire L

L l

l l-L 1

CONTACTS Note: Please provide name, title, mailing address, and phone number.

A. Survey Coordinator (i.e., contact for later clarification of questionnaire answers):

Brian H. Whitley Project Engineer Southern Nuclear Operating (,ompany Post Office Box 1295 Birmingham, Alabama 35201 (205) 868-5286 B. Computer Hardware ipecialist(s):

Same Contact C. Systems Software Specialist (s):

Same Contact D. Application-level Sof tware Specialist (s):

Sue Contact E. Telephone Systems Specialist (s):

Sam. Stact s

SELECTION OF DATA FEEDERS A. How many data feeders are there (six maximum)?

une feeder system per unit. Plant process computer /SPDS is the data feeder which transmits data parameters to a PC workstation. The PC workstation acts as the data sender and performt communication controls with the NRC ERDS control computer.

B. Identify the selected data feeders and provide the following for each:

(1) a short description of the categories of data points it will provide (e.g., met., rad., or plant data points, by unit) and (2) the rationale for selecting it if another system can also provide its categories of data points.

(1) All ERDS parameters listed in 10 CfR 50, Appendix E,Section IV except Containment Hydrogen Concentration.

(2) N/A C. Which data feeder is the '.ite time determining feeder? This should be the fecdar which is providing the majority of the data points.

Plant process computer /SPDS

DATA FEEDER INFORMATION Note: A new Section IV must be filled out for each feeder system selected.

GENERAL QUEST!0NS

1. Identification of Data Feeder
a. What is the name in local parlance given to this data feeder ,

(e.g., Emergency Response Information System)? Please give both the acronym and the words forming it.

Plant Process Computer (PPC)/ Safety Parameter Display System (SPDS)

b. Is this the site time determining feeder?

Yes

c. How often will this feeder transmit an update set to the EROS (in seconds)?

The PPC/SPDS transmits data to the PC workstation continuous 13 and updates at 60 second intervals.

2. Hsrdware/ Software Environment
a. Identify the manufacturer and model number of the data feeder hardware.

Data feeder - ENCORE (Gould) 6780 Data sender - Compact Deskpro 486/33L

b. Identify the operating system.

Data feeder - MPX 3.2 Data sender - SCO Unix

c. What method of timekeeping is implemented on this feeder system (daylight Savings, Standard, Greenwich)?

Daylight Savings

d. In what time zone is this feeder located?

Central

3. Data Communication Details
a. Can this data feeder provide asynchronous serial data communication (RS-232-C) with full-modem control?

Data sender will provide asynchronous serial data communication (RS-232-C) with full-modem control.

i i

b. Will this feeder transsit in ASCII or EBCDIC 7 ASCll
c. Can this feeder transmit Lt a serial baud rate of 2400 bps? If not, at what baud rate can it trsnsmit?

2400 hw all be used.

d. Does caerating system support XON/XOFF flow control?

Yes

1. Are any problems foreseen with the NRC using XON/X0FF to centrol the transmission of data?

No

e. If it is not feasible to reconfigure a serial port for the ERDS linkup (i.e., change the baud rate, parity, etc.), please explain why.

N/A

f. Do any ports currently exist for the EPOS linkup?

Data feeder (PPC/SPDS) has a spare port available.

1. If not, is it possible to add additional ports?

N/A

2. If yes, will the port be used solely by the ERDS or shared with other non-emergency-time users? Give details.

This port will not be shared with other non-emergency-time users.

4. Data Feeder Physical Environment and Management
a. Where is the data feeder located in terms of the TSC, EOF, and control room?

Both the data feeder and data sender will be located in the respective unit's plant computer room,

b. Is the data feeder protected from loss of supply of electricity?

Yes, UPS is provided.

c. Is there a human operator for this data feeder?

! Yes, ERDS activation will be via a menu selection from the PPC/SPDS display.

1. If so, how rnny hours a day is the feeder attended?

PPC/SPDS display is continuously available in the control room and TSC.

l t

ENCLOSURE 2 ERDS Data Point Library t

l-l 1

1 I

l Parameter Required by ERDS Rule FNP Parameter Transmit 1 pili)

RCS Pressure WR RCS Pressure 1 min. avg. of:

PT-402A & 403A RCS HL Temperature WR RCS HL Temperature for each loop 1 min. avg. of: J TE-413 i TE-423 TE-433 RCS CL Temperature WR RCS CL Temperature for each loop ,

1 min. avg. of:

TE-410 TE-420 TE-430 Core-Exit Temperature Core-Exit Thermocouples 5th Hottest Subcooling Margin Core-exit Subcooling TI-2354A TI-23558 Pressurizer Level WR Pressurizer Level 1 min. avg. of:

LT-459, 460, 461 RCS Charging Charging flow FT-122 Reactor Vessel Level RCITS Vpper Plenum Upper Head RCS flow RCS Flow For each loop 1 min. avg. of:

fl-414, 415, 416 fl-424, 425, 426 F1-434, 435, 436 Reacter Power Power Range Reactor Power 1 min. avg. of:

NE-41,42.43,44 NI Intermediate Range IR Flux NE-35 NE-36 NI 'ource Range SR Flux NE-31 NE-32 S/G Level WR S/G Level for each S/G LT-477 LT-487 LT-497

_- .. . . - . - . . . ~ . . _ . . . . .

P Parameter Required by ERDS Rule FNP Parameter Transmitter (s)

S/G Pressure S/G Pressure For each S/G 1 min, avg. of:

PT-474, 475, 476 PT-484, 485, 486 PT-494, 495, 496 Main Feedwater flow Main feedwater flow for each S/G 1 min. avg. of:

FE476B & 4778 FE4868 & 4878 FE4968 & 4978 Aux. Feedwater Flow AFW Flow For each S/G FT-3229A FT-3229B FT-3229C LHS1 Flow RHR Flow FT-605A FT-605B HHSI Flow S1 Header to BIT FT-943 RWST Level RWST Level (Channel 1) LT-501 CTMT Pressure WR CTMT Pressure Highest of:

PT950Y & PT950Z H2 Concentration (Not to be provided) ---

C1MT Sump Level Post Accident (WR) Avg. of:

CTMT Sump Level LT-3594A & B CTNT Temperature 1 Dome and 4 Cooler Inlet TE-3187E TE-3187F TE-3187G TE-3187H TE-31871 RCS Activity Gross failed fuel Detector R50 CTMT Radiation CTMT Radiation Highest of:

R27A & B SJAE Radiation SJAE (Extended Range) RISC Effluent Radiation Plant Vent Stack R14 R21 R22 SPING Noble Gas R29NG SPING Iodine R291 Main Steam Relief Valve R60A R60B R60C AFW Turbine Exhaust R600

Parameter Required  !

by EROS Rule FNP Parameter Transmitter (s) l Process Radiation N-16 Steam Line R70A R70B R10C Effluent Radiation Waste Disposal Liquid R18 I S/G Blowdown R238 l Wind Speed 35 ft. & 150 ft. XX-537 XX-541 ,

Wind Direction 35 ft. & 150 ft. XX-538 XX-530 Delta Temperature 35 ft. to 200 ft. XX-535 XX-544 (Not required) PVS Flow FT-2879 9

l l

i

4 Unit 1 Data Point Library Reference File l

l l

l-I I

I i-

,- . , ,,-,.~,.,,v.. . ~ . - - . - ~ . - , . . , - - , , . _ . . - - , - - ....,,.-e.-.- . - . . - ., - - - . . . . .. - . ... , , , -=- .~, - . - -

i DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992-Reactor Unit: FA1 Data feeder: PPC/SPDS NRC ERDS Parameter: RCS Pressure >

Point ID: PC 1402 A Plant Spec Point Desc: RCS WR Pressure Avg 1 MA Generic /Cond Desc: Reactor Coolant System Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr-Range: 3000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Senscrs: 2 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: RCS Loops A and C Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: 1 Min Avg of the scan frequency Avg of PT0402A and PT0403A, RCS Wide Range Pressure

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FA1 Data Feeder: PPC/SPDS NRC ERDS Parameter: HL Temp A Point ID: TC 0413 A Plant Spec Point Desc: RC HL A WR Temp 1 MA Generic /Cond Desc: SG A Inlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A 1

Minimum Instr Range: 0 Maximum Instr Range:- 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS A Hot leg Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A L

L Level Reference Leg: N/A Unique System Desc: Wide Range A Hot Leg,1 Min Avg of TE-413 l

L

, .- .. - .- . . . - . . - - . - . - - . . - . - . . . . - - - - . - , . ~ , . . - - . - - . - - - . - . , - .

DA1A PolNT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: HL Temp B Point 10: TC 0423 A Plant Spec Point Desc: RC HL B WR Temp 1 MA Ceneric/Cond Desc: SG B Inlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS B Hot leg Alarm / Trip Set Points: N/A N1. Detector Power Supply Cut Off Power Level: N/A N1 Detector Power Supply Turn-on-Power Level: ' N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range B Hot Leg, 1 Min Avg of TE-423

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: HL Temp C Point ID: TC 0433 A Plant Spec Point Desc: RC HL C WR Temp 1 MA Generic /Cond Desc: SG C Inlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700

  • Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS C Hot Leg Alarm / Trip Set Pcints: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A i

Level Reference Leg: N/A Unique System Desc: Wide Range C Hot Leg, 1 Min Avg of TE-433 i

l l-

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA1 Data Feeder: PPC/SPDS NRC ERDS Parameter: CL Temp A Point 10: TC 0410 A Plant Spec Point Desc: RC CL A WR Temp 1 MA Generic /Cond Desc: SG A Outlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS A Cold Leg Alarm / Trip Set Points: N/A NI Detector Power Supoly Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range A Cold Lug, 1 Min Avg of TE-410

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: CL Temp B Point 10: TC 0420 A Plant Spec Point Desc: RC CL B WR Temp 1 MA Generic /Cond Desc: SG B Outlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of' Sensors: 1 How Processed: Avg Sensor Locations: RCS B Cold Leg Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Irstrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range B Cold Leg, 1 Min Avg of TE-420

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data feeder: PPC/SPDS NRC ERDS Parameter: CL Temp C Point ID: TC 0430 A t Plant Spec Point Desc: RC CL C WR Temp 1 MA Generic /Cond Desc: SG C Outlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reftrence Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1  ;

How Processed: Avg Sensor Locations: RCS C Cold Leg Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A

.NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP_ Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range C Cold Leg,1 Min Avg of TE-430

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI ,

l Data feeder: PPC/SPDS l NRC ERDS Parameter: Temp Core Ex Point ID: TC 1200 Plant Spec Point Desc: Fifth Hottest Core Exit TC Generic /Cond Desc: Highest Temp at the Core Exit Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 6 Maximum Instr Range: 230t.

Zero Point

Reference:

N/A Refere1ce Point Notes: N/A PROC ar SENS: PROC Number of Sensors: 38 How Frocessed: Max Sensor L0 cations: Above active fuel a:tached to guide tubes Alarm / Trip Zet Points: N/A N1 Detector Poser Supply Cut-Off Power Leal: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference I 'g:. N/A Unique System Desc: Fifth hottest core exit TC was selected to correspond to the use of TC's in the SPDS CSFs and E0Ps

DATA POINT LIBPARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FAl Data feeder: PPC/SPDS NRC ERDS Parameter: Sub Margin Point ID: TMARCETA Plant Spec Point Desc: Core Exit TSAT Margin CH A Generic /Cond Desc: Saturation Temp - Highest CET Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: -2300 Maximum Instr Range: 664 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 19 How Processed: Calculation based on highest CEIC Sensor Locations: Above active fuel attached to guide tubes Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation

'for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Calculation performed by ICCMS and data linked L to PPC/SPDS. Individual TCs are excluded from j calculation if failed, h

1 DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 l Reactor Unit: FAl Data Feeder: PPC/SPDS l 1

NRC ERDS Parameter: Sub Margin Point ID: TMARCETB Plant Spec Point Desc: Core Exit TSAT Margin CH B Generic /Cond Desc: Saturation Temp - Highest CET Analog / Digital: A )

l

. Engr Units / Dig States: DEGF l Engr Units Conversion: N/A Minimum Instr Range: -2300 Maximum Instr Range: 664 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 19 ,-

How Processed: Calculation based on highest CETC Sensor Locations: Above active fuel attached to guide tubes Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Powe, Level: N/A NI Detector Power Supply l Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation l for DP Transmitters: N/A Level-Reference Leg: N/A Unique System Desc: Calculation performed by ICCMS and data linked to PPC/SPDS. Individual TCs are excluded from calculation if failed.

1

DATA POINT LIBRARY REFERENCE FILE ,

Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: PRZR Level Point ID: LC 1600 A Plant Spec Point Desc: PRZR Level Avg 1 MA Generic /Cond Desc: Primary System Pressurizer Level Analog / Digital: A Engr Units / Dig States: .  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100% ,

Zero Point

Reference:

PRZR Lower Tap Reference Point Notes: 0% corresponds to 294 gallons and 100%

corresponds to 10,179 gallons PROC or SENS: PROC Number of Sensors: 3 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: At lower tap near bottom of PRZR Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: Wet Unique System Desc: Composite Avg from LT0459, LT0460 and LT0461.

Transmitters are calibrated for 6540F and 2,270 psia.

1 DATA POINT LIBRARY REFERENCE FILE i l

I Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: RCS CHG/MU Point ID: FC 4658 Plant Spec Point Desc: Charging Line Corrected Flow IMA Generic /Cond Desc: Primary System Charging or Makeup Flow Analog / Digital: A j

Engr Units / Dig States: GPM l Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point Notes: N/A  :

PROC or SENS: PROC +

Number of Sensors: 1 How Processed: Avg Sensor Locations: Charging Header Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A ,

instrument Failure Mode: Low Temperature Compensation

.for DP Transmitters: Y Level Reference Leg: N/A

! Unique System Desc: Chg Pump Header. Flow which feeds all 3 RCS Loops. Density correction calculated by plant computer based on temp.

I

. DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: REAC VES LEV Point ID: LC 1603 Plant Spec Point Desc: Lowest Upper Plenum level Generic /Cond Desc: Reactor Vessel Water Level Analog / Digital: A <

Engr Units / Dig States:  %

Engr Units Conversion: N/A ,

Minimum Instr _ Range: 0 ,

Maximum Instr Range: 100 Zero Point

Reference:

TAF Reference Point Notes: 0% is 1 ft. 1 in, above TAF PROC or SCUS: PROC Number of Sensors: 2 How Processed: Lowest Sensor Locations: Within the HJTC probe below the upper support plate -

Alarm / Trip Set Points: Sensor Delta-T Exceeding NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low l

Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A l

L Unique System Desc: RVL probes each contain 8 sensors (heated and unheated TCs). Uncovery of a sensor causes the delta-T between the sensor TCs to exceed

.. 2000 F. Each ICCMS processor determines RVL l by deduction from uncovered sensors.

l

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: REAC VES LEV Point ID: LC 1602 Plant Spec Point Desc: Lowest Upper llead Level Generic /Cond Desc: Reactor Vessel Water Level Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TAT Reference Point Notes: 0% is 10 ft. 10 in above TAF PROC or SENS: PROC Number of Sensors: 6 How Processed: Lowest Sensor Locations: Within the HJTC probe above the upper support plate Alarm / Trip Set Points: Sensor Delta-T Exceeding 2000 f N1 Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: RVL probes each contain 8 sensors (heated and

unheated TCs). Uncovery of a sensor causes L the delta-T between the sensor TCs to exceed i 2000 f. Each ICCMS processor determines RVL l

by deduction from uncovered sensors.

i:

- - - . - _. .~

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: CORE FLOW Point ID: FC 0400A Plant Spec Point Desc: RCL A Flow Avg 1 MA Generic /Cond Desc: Total Reactor Coolant flow Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum-Instr-Range: 120 Zero Point

Reference:

N/A Reference Point Notes: N/A  ;

PROC or SENS: PROC Number of Sensors: 9 How Processed: Avg Sensor Locations: RCS Loop A Alarm / Trip Set Points: 92% low NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Calc 1 Min Avg of FE0414, FE0415 and FE0416

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor-Unit: FAl Data-Feeder: PPC/SPDS NRC ERDS Parameter: CORE FLOW Point ID: FC 0420A Plant Spec Point Desc: RCL B Flow Avg 1 MA ,

Generic /Cond Desc: Total Reactor Coolant flow Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 -

Maximum Instr Range: 120 Zero Point

Reference:

N/A Reference Point Notes:- N/A PROC or SENS: PROC Number of Sensors: 9 How Processed: Avg Sensor Locations: RCS Loop B Alarm / Trip Set Points: 92% Low NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply .

Turn-on Power Level: N/A

' Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A

. Unique System Desc: Calc 1 Min Avg of FE0424, FE0425 and FE0426

-... - _ . . . _ -. = - . . .. . - .__.- - . . -_

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: CORE FLOW Point ID: FC 0440A Plant Spec Point Desc: RCL C Flow Avg 1 MA Ge1eric/Cond Desc: Total Reactor Coolant flow Analog / Digital: A Engr Units / Dig States:  %

Engr Units-Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 120 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 9 How Processed: Avg Sensor Locations: RCS Loop C Alarm / Trip Set Points: 92% Low NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Calc 1 Min Avg of FE0434, FE0435 and FE0436

l DATA POINT LIBRARY REFERENCE FILE Date: February 28. 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: N1 Power Range Point ID: NC 1100A Plant Spec Point Desc: Powei Range flux Avg 1 MA Generic /Cond Desc: Nuclear Instruments, Power Range Analog / Digital: A Engr Units / Dig States:  %

Engr Units. Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 120 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 8 How Procersed: Redundant Sensor Algorithm Avg Sensor Locations: Adjacent to Reactor Vessel in NI Instrument Ports Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A HI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: 1 Min Avg of the scan frequency avg of NE0041, NE0042, NE0043, NE0044 Power Range Flux Channels 1 - 4. These are outputs from the Power Range NI Drawers and are the combined output of the upper and lower detectors for l

each channel.

DATA POINT LIBRARY REFERENCE FILE l Date: February 28, 1992 Reactor Unit: FA1 Data Feeder: PPC/SPDS NRC ERDS Parameter: NI INTER RNG Point ID: NE 0035 Plant Spec Point Desc: Int Range Flux Chan A Generic /Cond Desc: Nuclear Instruments, Intermediate Range Analog / Digital: A Engr Units / Dig States: AMPS Engr Units Conversion: N/A Minimum Instr Range: 1.0 E-11 Amps Maximum Instr Range: 1.0 E-3 Amps Zero Point

Reference:

N/A Reference Point Notes: N/A ,

PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Excore Instrument Ports Alarm / Trip Set Points: Hi 0.99 E-6 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

i I

i-

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: NI INTER RNG Point ID: NE 0036 Plant Spec Point Desc: Int Range Flux Chan B Generic /Cond Desc: Nuclear Instruments, Intermediate Range Analog / Digital: A Engr Units / Dig States: AMPS Engr Units Conversion: N/A Minimum Instr Range: 1.0 E-11 Amps 5 Maximum Instr Range: 1.0 E-3 Amps Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor locations: Excore Instrument Ports _

Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

l DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: NI SOURC RNG Point ID: NE 0031' .

Plant Spec Point Desc: Source Range Flux Chan A Generic /Cond Desc: huclear Instruments, Source Range Analog / Digital: A Engr Units / Dig States: CPS Engr Units Conversion: N/A Minimum Instr Range: 'I.0 (CPS)

Maximum Instr Range: 1.0 E 6 (CPS)

Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Excore Instrument Ports Alarm / Trip Set Points: Hi 0.9 E 5 NI Detector _ Power Supply _.

Cut-Off Power Level: Detectors de-energize when going above 10% Rx power NI Detector Power Supply Turn-on-Power Level: Detectors energize at P-6 1.0 E-6 Amps Instrument Failure Mode: Low Temperature Compensation for DP Troasmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA1 Data feeder: PPC/SPDS NRC ERDS Parameter: NI SOURC RNG Point ID: NE 0032 Plant Spec Point Desc: Smoothed Source Range SUR CHAN B Generic /Cond Desc: Nuclear Instruments, Source Range Analog / Digital: A Engr Units / Dig States: DPM Engr _ Units Conversion: N/A Minimum Instr Range: 1.0 (CPS)

Maximum Instr Range: 1.0 E 6 (CPS)

Zero Point

Reference:

.N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1

.How Processed: N/A Sensor Locations: Excore Instrument Ports Alarm / Trip Set Points: N/A  ;

NI Detector Power Supply

-Cut-Off Power Level: Detectors de-energize when going above 10% Rx power NI. Detector Power Supply Turn-on Power Level: Detectors energize at P-6 1.0 E-6 Amps Instrument Failure Mode: Low Temperature Compensation for DP Transmitters:- N/A Level Reference Leg: N/A Unique System Desc:

DATA-POINT LIBRARY REFERENCE FILE i Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Level A Point ID: LT 0477 Plant Spec Point Desc: SG A Wide Range level Generic /Cond Desc: SG A Water Level Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A

. Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 0% corresponds to the TUBSHT and 70%

corresponds to the top of tube bundle.

PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Steam Generator A

. Alarm / Trip Set Points: Lo 43%, Hi 55%

NI Detet. tor Power Supply Cut-Off Power Level: N/A

- NI Detector Power Supply Turn-on Power Level
N/A Instrument Failure Mode: Low r

Temperature Compensation for DP Transmitte'rs: N/A Level Reference Leg: Wet l' Transmitters are cold calibrated.

i Unique System Desc:

_. _ , _ _ .,. .._ _ _. ~ _ . --

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parimeter: SG Level B Point ID: LT 0487 Plant Spec Point Desc: SG B Wide Range Level Generic /Cond Desc: SG B Water Level Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 .,

Maximum Instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 0% corresponds to the TUBSHT and 70%

corresponds to the top of the bundle.

PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Steam Generator B Alarm / Trip Set Points: Lo 43%, Hi 55%

N1 Detector Power Supply Cui.-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: Wet Unique System Desc: Transmitters are cold calibrated.

DATA POINT LIBRARY REFERENCE FILE Date: February 28,-1992 l r.eactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Level C Point ID: LT 0497 Plant Spec Point Desc: SG C Wide Range level Generic /Cond Desc: SG C Water Level Analog / Digital: - A Engr bnits/ Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 0% corresponds to the TUBSHT and 70%

corresponds to the top of tube bundle.

PROC or SENS: SENS Number of Sensors: 1 How Processed:. N/A Sensor Locations: Steam Generator C Alarm /T_ rip Set Points: Lo 43%, Hi 55%

NI Detector Power Supply Cut-Off Power Level: N/A L NI Detector Power Supply Turn-on Power Level: N/A L

Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A i

j. Level Reference Leg: Wet

. Unique System Desc: Transmitters are cold calibrated.

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: SG Pressure A Point ID: PC 2300 A Plant Spec Point Desc: SG A Pressure Avg 1 MA Generic /Cond Desc: SG A Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1200 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 3 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Steam Generator A Alarm / Trip Set Points: Lo 600, Hi 1025 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: 1 Min Avg of the scan frequency Avg of PT0474, PT0475, PT0476, SG A Outlet Pressure Channels 1, 2 and 3

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Pressure B Point ID: PC 2301 A Plant Spec Point Desc: SG B Pressure Avg 1 MA Generic /Cond Desc: SG B Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1200 Zero Point

Reference:

N/A-Reference Point Notes: N/A PROC of SENS: PROC Number of Sensors: 3 How Processed: Redundant Sensor Algorithm Avg Sensor locations: Steam Generator B i

Alarm / Trip Set Points: Lo 600,-Hi 1025 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply

' Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation l

for.DP Transmitters: N/A Level Reference' Leg: N/A

! Unique System Desc: 1 Min Avg of the scan frequency, Avg of PT0484, PT0485, PT0486, SG B Outlet Pressure Channels 1, 2 and 3 9 mJ e 9 ee w ' - - ' ,- e'- +-+mriy+ (' p.m -- e.m w 9-M m- w ww--=r:- ~

rzr-*--r- p * *

  • N

- ._ . . _ =

DATA. POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Pressure C Point ID: PC 2302 A Plant Spec-Point Desc: SG C Pressure Avg 1 MA Generic /Cond Desc: SG C Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1200 Zero Point

Reference:

N/A Reference-Point Notes: N/A PROC or SENS: PROC Number of Sensors: 3 i

How~ Processed: Redundant Sensor Algorithm Avg Sensor Locations: Steam Generator C Alarm / Trip Set Points: Lo 600, Hi 1025 NI Detector Power Supply Cut-Off-Power Level: N/A L

NI Detector Power. Supply

-Turn-on Power Level:. N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level- Reference Leg: N/A Unique System Desc: 1 Min Avg of the scan frequency Avg of PT0494, PT0495, PT0496, SG C Gutlet Pressure Channels 1, 2 and 3

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: MN FD FL A Point.ID:- FC 4655 Plant Spec Point Desc: SG A fiain FW Corr Flow 1 MA Generic /Cond Desc: SG A Main FW Flow Analog / Digital: A Engr Units / Dig States: KLB/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr-Range: 5000 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: -PROC L

Number of Sensors: 2 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Main FW Line to SG A Alarm / Trip Set Points: Lo -2, Hi 5000 NI Detector Power Supply Cut-Off Power Level: N/A p-NI Detector Power Supply-Turn-on-Power Level: N/A Instrument Failure Mode: Low Temperature Compensation ,

for DP Transmitters: N/A Level Reference Leg: N/A l Unique System Desc: 1 Min Avg density corrected SG A Main L Feedwater Flow. Density correction calculated based on FW Temp. Sensors are FE4768 and FE477B.

Date: DATA POINT LIBRARY ILE REFERENCE F Reactor Unit: February 28, 1992 FA1 Data Feeder:

PPC/SPDS NRC ERDS Parameter:

Point ID: MN FD FL B FC 4656 Plant Spec Point Desc:

Generic /Cond Dest: SG B Main FW Corr Flow 1 MA Analog / Digital: SG A Main FW Flow

( A Engr Units / Dig States:

KLB/HR Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

5000 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS:

PROC Number of Sensors:

2 How Processed:

Sensor Locations: Redundant Sensor Algorith m Avg Alarm / Trip Set Points: Main FW Line to SG B Lo -2, NI Detector Power Su Hi S000 Cut-Off Power Level:pply NI D N/A Turnetector Power Supply on Power Level:

N/A Instrument Failure Mode: Low Temperature Compensa for DP Transmitters: tion N/A Level Reference Leg:

N/A t'nique System Desc:

1 Min Avg densi based on FW Temp. Density correctionfeedwa FE4878.

Sensors are FE486B andcalculated i

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: HN FD FL C Point ID:~ FC 4657 Plant Spec Point Desc: SG C Main FW Corr Flow 1 MA Generic /Cond Desc: SG C Main FW Flow Analog / Digital: A Engr Units / Dig States: KLB/HR Engr Units Conversion: N/A Minimum-Instr Range: 0 Maximum Instr Range: 5000 Zero Point

Reference:

0-Reference Point Notes: N/A PROC or SENS: PROC Number of. Sensors: 2 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Main FW Line to SG C Alarm / Trip Set Points: Hi S000

(

NI Detector Power Supply Cut-Off Power Level: N/A l NI Detector Power Supply l Turn-on Power Level: li/A ~

l l

Instrument Failure Mode: Low L Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: 1 Min Avg dcnsity corrected SG C Main feedwater Flow. Density correction calculated based on FW Temp. Sensors are FE4968 and FE497B.

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992

-Reactor Unit: FA1 Data Feeder: PPC/SPDS NRC ERDS Parameter: AX FD FL A Point ID: FT 3229A Plant Spec Point Desc: Aux FW Flow to SG A Generic /Cond Desc: SG A Aux FW Flow Analog / Digital: A Engr Units / Dig States: GPH Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 800 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Aux FW Line to SG A Alarm / Trip Set Points: N/A NI Detector Power Supply

. Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation

- for DP Transmitters: N/A

-Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 4

Reactor Unit: FAl

- Data Feeder: PPC/SPDS

-NRC ERDS Parameter: AX FD FL B Point ID: FT 3229B Plant Spec Point Desc: Aux FW Flow to SG B Generic /Cond Desc: SG B Aux FW Flow Analog / Digital: A Engr-Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 800 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS l Number of Sensors: 1 How Processed: N/A Sensor Locations: Aux FW Line to SG B Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power-Supply Turn-on Power Level: N/A Instrument Failure Mode: Low

~ Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

1' I

t

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: AX FD FL C Point ID: FT 3229C Plant Spec Point Desc: Aux FW Flow to SG C Generic /Cond Desc: SG C Aux FW flow Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Irstr Range: 0 Maximum Instr Range: 800 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Aux FW Line to (G C Alarm / Trip-Set Points: N/A NI Detector Power Supply Cut-Off Power level: N/A NI Detector Power Supply Turn-on Power' Level: N/A Instrument Failure Mode: Low

, Temperature Compensation for DP Transmitters: N/A

. Level Reference Leg: N/A l'

l. Unique System Desc:

i L _. . . _ . . .

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit:- FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: LP SI Flow Point ID: FE 0605A Plant Spec Point Desc: RHR Train A Flow Generic /Cond Desc: Low Pressure SI Flow - Train A

Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 4250

'Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Downstream of the Train A RHR Hx Alarm / Trip Set Points: Hi-5000 11 Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level:

N/A LInstrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A

Level Reference Leg: N/A Unique System Desc:

i-

1 DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data feeder: PPC/SPDS NRC ERDS Parameter: LP SI Flow Point 10: FE 0605B Plant Spec Point Desc: RHR Train B Flow Generic /Cond Desc: Low Pressure SI Flow - Train B Analog / Digital: A Engr Units / Dig States: GPM

! Engr Units Conversion: N/A Minimum-Instr Range: 0 Maximum Instr Range: 4250 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Downstream of the Train B RHR Hx Alarm / Trip Set Points: Hi 5000 NI Detector Power Supply Cut-Off Power Level: N/A i . .

NI Detector Power Supply

-Turn-on-Power Level: N/A Instrument Failure Mode: Low

-Temperature Compensation I

for DP Transmitters: N/A Level- Reference Leg: N/A

! Unique System Desc:

l

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA1

' Data Feeder: PPC/SPDS NRC ERDS Parameter: HP SI Flow Point ID: FT 0943 Plant Spec Point Desc: SI Header to BIT Generic /Cend Desc: HP SI Flow Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1000 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor locations: HP SI Header to BIT Alarm / Trip Set. Points: N/A NI Detector Power Supply Cut-Off Power Level: 'N/A NI Detector Power Supply-Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A l Level Reference Leg: N/A l

Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: BWST Level Point ID: LT 0501 Plant Spec Point Desc: RWSi Level Channel 1 Generic /Cond Desc: Borated Water Storage Tank Level Analog / Digital: A Engr Units / Dig States: Feet Engr. Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 40 Zero Point

Reference:

TNKBOT Reference-Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: RWST Alarm / Trip Set Points: Lo 12.6 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply

-Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation

.for DP Transmitters: N/A Level-Reference Leg: N/A Unique System Desc: One of two channels

DATA P0lNT LIBRARY REFERENCE FILE Date: February 28, 1992 ,

Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: CTMNT Pressure Point ID: PC 3700 Plant Spec Point Desc: Highest CTMT Pressure Generic /Cond Desc: Containment Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: -5 Maximum Instr Range: 225 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 2 How Processed: Algorithm Max Sensor Locations: CTMT Alarm / Trip Set Points: Hi 4, Hi Hi 16.2, Hi Hi Hi 27.0 NI Detector Power Supply Cut-Off Power level.: N/A NI Detector Power Supply lurn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Highest containment pressure calculated from l PT0950Y and Z, containment pressure extended range.

l l

l _ _

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl

' Data Feeder: PPC/SPDS NRC ERDS-Parameter: CTMNT SMP R Point ID: LC 1501 Plant Spec- Point Desc: CTMT Sump Level Avg Generic /Cond Desc: Containment Sump Level Analog / Digital: A Engr Units / Dig States: Feet Engr Units Conversion: N/A-Minimum Instr Range: 0 Maximum Instr Range: 10 Zero Point-

Reference:

Bottom of Sump Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 2 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Containment Sump

. Alarm / Trip Set Points: Lo 1.0, Hi 5,0 NI-Detector Power Supply Cut-Off Power -Level: N/A NI Detector Power Supply-Turn-on Power level: N/A Instrument Failure Mode: Low Temperature Compensation

-for DP Transmitters: N/A Level Reference Leg: N/A Unique-System Desc: Containment Sump Level Avg of LT 3594A and LT 3594B

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: CTMNT TEMP

-Point ID: TE 3187E Plant Spec Point Desc: CTHT Cooler D Air Inlet Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 150

.Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS

. Number of Sensors: 1 How Processed: N/A

-Sensor Locations: CTMT Cooler D Air Inlet Alarm / Trip Set Points:- Hi-130 NI Dei.ettor Power -Supply Cut-Off Power Level: N/A

.NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

l

DATA POINT' LIBRARY REFERENCE FILE l

Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: CTMNT TEMP Point'ID: TE-3187F Plant Spec Point Desc: CTMT Cooler C Air Inlet Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: CTMT Cooler C Air Inlet Alarm / Trip -Set Points: -Hi 130

_ NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level:

N/A Instrument Failure Mode: Low Temperature Compensation for DPl Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

+n- , w 4 w -v

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: CTMNT TEMP Point ID: TE 3187G Plant Spec Point Desc: CTMT Cooler B Air Inlet Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number-of Sensors: 1 How Processed: N/A Sensor Locations: CTMT Cooler B Air Inlet Alarm / Trip Set Points: _Hi 130 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power. Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation

'for DP Tra'smitters: N/A Level Reference-Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS

-NRC ERDS Parameter: CTMNT TEMP Point ID: TE 3187H Plant Spec Point Desc: CTMT Cooler A Air Inlet Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A

' Minimum Instr Range: 0 Maximum Instr Range: 150

-Zero Point

Reference:

N/A Reference Point Notes: N/A

-PRCC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: CTMT Cooler A Air Inlet Alarm / Trip Set Points: Hi-130 NI: Detector Power Supply Cut-Off-Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A-

. Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY-REFERENCE FILE  ;

Date: February 28, 1992 Reactor Unit: FAl Data' Feeder: PPC/SPDS NRC'ERDS Parameter: CTMNT TEMP Point ID: TE 31871 Plant Spec Point Desc: CTMT Dome Inside Air Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 150 Zero Point

Reference:

N/A l

l Reference Point Notes: N/A PROC or SENS: SENS 1.

Number of Sensors: 1 How Processed: N/A l Sensor Locations: Containment Dome Alarm / Trip Set Points: Hi 130 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply l Turn-on' Power Level: N/A Instrument Failure Mode: Low l

Temperature. Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: RCS LTDN RAD Point ID: RE 0050 Plant Spec Point Desc: Gross failed Fuel Detector Generic /Cond Desc: Rad Level of RCS Letdown Line Analog / Digital: A Engr Units / Dig St.tes: CPM Engr Units Conversion: N/A Minimum Instr Range: 10

. Maximum Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Pipe Penetration Room Alarm / Trip Set Points: Hi 11,000 NI Detector Power Supply-Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A' Instrument-Failure Mode: Low Temperature. Compensation for DP Transmitters: N/A Level Reference Leg: . N/A

!!nique System Desc:


,r - -

, = . ,- - - - , , - - n r - . , . . . . - , . . .

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA1 Data Feeder: PPC/SPDS NRC-ERDS Parameter: CTMT RAD Point ID: RC 3702 Plant Spec Point Desc: Highest Hi Level CTMT Radiation Generic /Cond Desc: Radiation Level in the Containment Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 1.0 Maximum Instr Range: 1.0 E 7 Zero Point

Reference:

N/A Reference Point Notes: N/A

-PROC or SENS: PROC p Number of Sensors: 2 1

How Processed: Algorithm Max Sensor Locations: Containment l Alarm / Trip Set Point:: 10.0 l NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply L

. Turn-on Power Level: N/A Instrument. Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level-Reference Leg: N/A Unique System Desc: RC 3702 selects the highest output of R27A or R278.

l l

p

I DATA POINT LIBRARY REFER [lJCE FILE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC EhDS Parameter: COND AE RAD Point ID: RE 0015C Plant Spec Foint Desc: SJAE Exhaust High Range Monitor Generic /Cond Desc; Condenser Air Ejector Radioactivity Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Steam Jet Air Ejector Alarm / Trip Set Points: Hi 2.8 E-2 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: St ar t air ejector exhaust high range radia;,an monitor

DATA PolNT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 0014 Plant Spec Point Desc: Vent Gas Monitor Generic /Cond Desc: Radioactivity of Released Cases Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed:

  • N/A Sensor Locations: Plant Vent Stack Alarm / Trip Set Points: Hi 17,000 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A i

Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

)

CATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FA1 Data feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD l

Point ID: RE 0021 Plant Spec Point Desc: Vent Air Particle Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Inste Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Alarm / Trip Set Points: Hi 1200 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Partmeter: EFF GAS RAD Point ID: RE 0022 Plant Spec Point Desc: Vent Gas Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point flotes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Alarm / Trip Set Points: Hi 156 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for.DP Transmitters: N/A Level Reference Leg: N/A

Unique System Desc:

L i

k I

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FAl Data feeder: PPC/SPDS NRC ERD $ Parameter: Eff GAS RAD Point 10: RG 0029B - NG Plant Spec Point Desc: Plant Vent Stack High Range Noble Gas Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: uC1/ML Engr Units Conversion: N/A Minimum Instr Range: 1.10 E-7 Maximum Instr Range: 1.44 E S Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 3 How Processed: Algorithm selects from low, mid, and high range detectors Sensor Locations: Plant Vent Stack Alarm /1 rip Set Points: 4.44 E-4 NI Detector Power Supply Cut-Off Power Level: N/A

- NI Detector Power Supply Turn-on Power level: N/A Instru:aent failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FAl ,

Data feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD ,

Point 10: RE 00298 - 12 Plant Spec Point Desc: Plant Vent Stack lodine - 131 ,

Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: uC1/ML Engr Units Conversion: N/A Minimum Instr Range: 1.40 E-11 Maximum-Instr Range: 4.00 E-6 Zero Point

Reference:

N/A

, Reference Point Notes: N/A PROC or SENS: SENS  ;

Number of Sensors: 1 How Processed: N/A f

Sensor Locations: Control Room Penthouse / Plant Vent Stack Alarm / Trip Set Points: 1.0 E-6

(- NI Detector Power Supply Cut-Off Poder Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters:- N/A Level Refertnce Leg: N/A Unique System Desc:

l l

l

. ~ . . . . _ _ . . . . . _ . ~ . , _ . , _ _ _ _ . . ~ - _ . - _ _ _ - . . _ . . _ , . . . _ . , . - _ , _ . _ . _ , , , , - . _ ,- . - - . . , . .

DATA POINT LIBRARY REFERENCE flLE February 28, 1992  !

Date:

Reactor Unit; FAl Data feeder: PPC/SPDS ,

NRC ERDS Parameter: Eff GAS RAD Point ID: RE 0060A Plant Spec Point Dese: SG A Atmospheric Relief Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: _N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS ,

Number of Sensors: 1 1

How Processed: N/A Sensor locations: Auxiliary Building Roof Alarm / Trip Set Points: 3.50 E-2 NI. Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

l  ;

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 0060B Plant Spec Point Desc: SG B Atmospheric Relief Monitor Generic /Cond Desc: Radioactivity of Released Gases Analol/ Digital: A Engr nits / Dig States: R/HR Engr Uiits Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Roof -

Alarm / Trip-Set Points: 3.50 E-2 NI Detector Power Supply '

Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Fhilure Mode: Low Temperature Compensation for DP. Transmitters: N/A Level Reference . Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS PAD Point 10: RE 00600 Plant Spec Point Desc: SG C Atmospheric Relief Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Roof Alarm / Trip _ Set Points: 3.50 E-2 NI 9etector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

y"a w=r'-"em-'7-?e- m* rmm+--w+e m 9=me e1= aw 4".tre r*en+ --a-

DATA POINT LIBRARV REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA1 Data feeder: PPC/SPDS ,

NRC ERDS Parameter: EFF GAS RAD Point ID: RE 00600 Plant Spec Point Desc: Aux feed Turbine Exhaust Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How-Processed: N/A Sensor Locations: Auxiliary Building Roof Alarm / Trip Set Points: 3.50 E-2 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A .

Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

I DATA POINT LIBRARY REFERENCE FILE i

Date: February 28, 1992 l Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: MAIN SL A Point ID: RE 0070A  ;

Plant Spec Point Desc: N16 Leak Detection System S/G A l

Generic /Cond Desc: Stm Gen A Steam Line Rad Level Analog / Digital: A Engr Units / Dig States: GPD Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 1,000

-Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Main Steam Line A Alarm / Trip Set Points: 10 N1 Detector Power Supply Cut-Off Power Level: N/A NI Detet.or Power Supply t

Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation l for DP Transmitters: N/A Level Reference Leg: 'N/A Unique System Desc:

l

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: MAIN SL B Point ID: RE 0070B Plant Spec Point Desc: N16 Leak Detection System S/G B Generic /Cond Desc: Stm Gen B Steam Line Rad Level Analog / Digital: A Engr Units / Dig States: GFD Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Main Steam Line B Alarm / Trip Set Points: 10 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low l Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: MAIN SL C Point ID: RE'*tX Plant Spec Point Desc: N16 Leak Detection System S/G C Generic /Cond Desc: Stm Gen C Steam Line Rad Level Analog / Digital: A Engr Units / Dig States: GPD Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PfwC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Main Steam Line C Alarm / Trip Set _ Points. 10 NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply

. Turn-on Power Lovel: N/A Instrument Failure Mode: Low Temperature Compensation for DP-Transmitters: N/t Level Reference Leg: N/A

-Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data feeder: PPC/SPDS NRC ERDS Parameter: EFF LIQ RAD Point ID: RE 0018 l l

Plant Spec Point Desc: Waste Disposal Liquid Monitor j Generic /Cond Dese: EFF LIQ RAD Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A Minimum Instr. Range: 10 Maximum Instr Range: 10 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Liquid Effluent Line Alarm / Trip Set Points: Variable determined by 00CM NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A ,

Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

i

- ,, ,, ,.. - -,a-,..,,-.. , , -. , ,5 , , - . . - - , - , , , - , - , . . , - . - , - . - . , . - - - - . .

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FA1 Data feeder: PPC/SPDS NRC ERDS Parameter: Eff LIQ RAD Point ID: RE 0023B Plant Spec Point Desc: SG Blowdown Treatment Monitor Generic /Cond Desc: Radioactivity of Released Liquids Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor locations: SG Blowdown Effluent Line Alarm / Trip Set Points: 1,000 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low-Temperature Compensation for DP--Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data feeder: PPC/SPDS NRC ERDS Parameter: WIND SPEED Point ID: WS35FT Plant Spec Point Desc: Wind Speed 35' Elev Generic /Cond Desc: Wind Speed at Reactor Site Analog / Digital: A Engr _ Units / Dig States: MPH Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply-Turn-on Power Level: N/A Instrument Failure Mode: Low i

Temperature Compensation for DP Transmitters: N/A Level. Reference Leg: N/A Unique System Desc: Het tower base is at 182 feet MSL l

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 l Reactor Unit: FAl Data Feeder: PPC/SPDS NRC [RDS Parameter: WIND SPEED Point ID: WS150FT Plant Spec Point Desc: Wind Speed 150' Elev Generic /Cond Desc: Wind Speed at Reactor Site Analog / Digital: A Engr Units / Dig States: MPH Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Primary Met lower Alarm / Trip Set Points: N/A NI' Detector Power Supply Cut-Off Power Level: N/A NI~ Detector Power Supply.

Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Het tower base is at 182 feet MSL

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAl Data Feeder: PPC/SPDS NRC ERDS Parameter: WIND DIR Point ID: WD35FT Plant Spec Point Desc: Wind Direction 35' Elev Generic /Cond Desc: Wind Directton at Reactor Site i Analog / Digital: A Engr Units / Dig States: DEGFR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 540 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: As is Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Met tower base slab is at 182 feet MSL. Wind direction is "from."

i

, .. _ - . - . - - _ _ . . - - _ - . - = - .- -- - - . _ - . . . - . - . -_

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA)

Data feeder: PPC/SPDS NRC ERDS Parameter: WIND DIR Point ID: WD150FT t Plant Spec Point Desc: Wind Direction 150' Elev .

Generic /Cond Desc: Wind Direction at Reactor Site Analog / Digital: A Engr Units / Dig States: DEGFR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 540 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors:

- 1 How Processed: N/A Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: As is '

Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Met tower base slab is at 182 feet MSL. Wind direction is "from,"

. _ . . - _ . . - . _ - . = - - _. . _ . .- - -- - _ . _ . -

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI Data Feeder: PPC/SPDS NRC ERDS Parameter: STAB CLASS Point-ID: STCLASS Plant Spec Point Desc: Stability Class Delta Temp Generic /Cond Desc: Air Stability at Reactor Site  !

Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: -100F Haximum Instr Range: +200F Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 2 How Processed: N/A Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A 1

Unique System Desc: Temp Difference Between 35 feet and 200 feet t

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FAI l Data Feeder: PPC/SPDS l

NRC ERDS Parameter:

N/A Point ID: FT 2879 Plant Spec Point Desc: Plant Vent Stack Flow Generic /Cond Desc: N/A Analog / Digital: A Engr Units / Dig States: CFM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 170,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Plant Vent Stack Alarm / Trip Set Points: N/A N1 Detector Power bupply Cut-Off Power Level: N/A NI Detector Power Supply

-Turn-on Power Level:. N/A Instrument Failure Mode: Low Temperature Compensation for DP. Transmitters: N/A Level Reference Leg: N/A L,iique System Desc:

Unit 2 Data Point Library Reference File t

It r

)

DATA POINT LIBRARY REFERENCE file

-Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPD!.

NRC ERDS Parameter: RCS Pressure Point ID: PC 1402 A Plant Spec Point Desc: RCS WR Pressure Avg 1 MA Generic /Cond Desc: Reactor Coolant System Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 3000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 2 How Processed:-- Redundant Sensor Algorithm Avg Sensor Locations: RCS Loops A and C Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply j .- Turn-on Power Level: N/A I- -Instrument Failure Mode: Low i Temperature Compensation for DP Transmitters:- :N/A Level Reference Leg: N/A ,

Unique Syst;m D' esc: 1 Min Avg of the scan frequency Avg of PT0402A and PT0403A, RCS Wide Range Pressure

a DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: HL Temp A Point ID: TC 0413 A Plant Spec Point Desc: RC HL A WR Temp 1 MA Generic /Cond Desc: SG A Inlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr _ Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS A Hot leg Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP' Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range A Hot Leg,1 Min Avg of TE-413 1

- .- . .- - - . .- . . . -. . .-. __. - - - _ = - .. . . . - =.

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: HL Temp B Point ID: TC 0423 A Plant Spec Point Dese: RC HL B WR Temp 1 MA Generic /Cond Desc: SG B Inlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: _0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS B Hot Leg Alarm / Trip Set Points: N/A

- NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A-Instrument Failure Mode: Low Temperature Compensation L for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range B Hot Leg, 1 Min Avg of TE-423 e- e e- w q---rra v-n-'* ---sN-'-sv O-V t'-Y+

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: HL Temp C Point 10: TC 0433 A Plant Spec Point Desc: RC HL C WR Temp 1 MA Generic /Cond Desc: SG C Inlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr _ Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC l Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS C' Hot Leg Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature. Compensation for DP Transaitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range C Hot Leg, 1 Min Avg of TE-433

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 l

Reactor Unit: FA2 Data Feeder: PPC/SPDS l l

NRC ERDS Parameter: CL Temp A Point 10: TC 0410 A Plant Spec Point Desc: RC CL A WR Temp 1 MA Generic /Cond Desc: SG A' Outlet Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor Locations: RCS A Cold Leg Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power level: N/A o

y NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A l Level Reference Leg: N/A Unique System Desc: Wide Renge A Cold Leg, 1 Min Avg of TE-410 i

w -%--me,-o, --,w- ----w,r1e ,, w*vmr- -- --+-e-- wee---.mv-* e-. +. re.--=,v- .---:5 w----vw-re w aw-m-e--* y- r- e- e em ww++i +r~+ +--v- + w-+"

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: CL Temp B Point ID: TC 0420 A Plant Spec Point Desc: RC CL B WR Temp 1 MA Generic /Cond Desc: SG B Outlet Temperature Analog / Digital: A __

Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg

~

Sensor locations: RCS B Cold leg Alarm / Trip Set Points: li/A NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Wide Range B Cold Leg, 1 Min Avg of TE-420

DATf. POINT LIBRARY-REFERENCE FILE-Date: February 28, 1992 Reactor Unit: FA2-Data Feeder: PPC/SPDS NRC ERDS Parameter: CL Temp C Point 10: TC 0430 A Plant Spec Point Desc: RC CL C WR Temp 1 MA Generic /Cond Desc: SG C Outlet Temperature Analog / Digital: A

- Engr Units / Dig States
DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 1 How Processed: Avg Sensor. Locations: RCS C Cold leg Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-or' Power Lovel: N/A Instrute.ent Failure Mode: Low Temperature Compensation

.for DP Transmitters: N/A Level Reference _ Leg: N/A Unique' System Desc: Wide Range C Cold Leg, 1 Min Avg of TE-430

,7-DATA POINT LIBRARY REFERENCE FILE pte: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: Temp Core Ex Point 10:- TC 1200 Plant Spec Point Desc: Fifth Hottest Core Exit TC Generic /Cond Desc: Highest Temp at the Core Exit Analog / Digital: A Engr Units / Dig-States: nEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 2300 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 38 How Processed: Max Sensor-Locations: Above active fuel attached to guide . tubes Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A-NI Detector Power Supply L . Turn-on-Power Level: N/A t-

' Instrument Failure Mode: Low i Temperature Compensation.

L f'ar DP Transmitters: N/A t

l Level Reference Leg: N/A l-l Unique System Desc: Fifth hattest core exit TC was selected to l correspond to the use of TC's in the SPDS CSFs l_ and E0Ps L

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder:. PPC/SPDS NRC ERDS Parameter: Sub Margin Point ID: TMARCETA =

Plant Spec Point _ Desc: Core Exit TSAT Margin CH A Generic /Cond Desc: Saturation Temp - Highest CET Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: -2300 Maximum Instr Range: 664 Zero Point-

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 23 How Processed: Calculation based on highest CETC Sensor Locations: Above active fuel attached to guide tubes

' Alarm / Trip Set- Points: N/A NI Detector Power Supply Cut-Off Power _ Level: N/A NI Detector Power Supply Turn-on Powar Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Calculation nerformed by ICCMS and data linked

, to PPC/SPDS. Individual TCs are excluded from calculation if failed.

DATA P0 INT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2-Datafeeder: PPC/SPDS NRC ERDS Parameter: Sub Margin

' Point ID: TMARCETB Plant Spec Point Desc: Core Exit TSAT Margin CH B Generic /Cond Desc: Saturation Temp - Highest CET Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: -2300 Maximum Instr Range: 664 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 24 How Processed: Calculation based on highest CETC Sensor Locations: Above active fuel attached to guide tubes Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detectcr' Power Supply

' Turn-on Power Level: N/A

' Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Calculation performed by ICCMS and data linked -

! to PPC/SPDS. Individual TCs are excluded from calculation if failed.

p - , , - , e ., ,,,,v-,,,,--,- , r- . , - .- -,,,,n~ ...--,,. ., nn-, ~ , - - - - , - - - , , -,, --,,-, . , --

.. _- - - .= - .-_- - - - .

' DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: PRZR Level Point ID: LC 1600 A Plant Spec Point Desc: PRZR Level Avg 1 MA Generic /Cond Desc: Primary System Pressurizer Level Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100%

Zero Point

Reference:

PRZR Lower Tap Reference Point Notes: 0% corresponds to 294 gallons and 100%

corresponds to 10,179 gallons.

PROC or SENS: PROC Number of Sensors: 3 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: At lower tap near bottom of PRZR Alarm / Trip Set Points: N/A NI' Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low 1 Temperature Co rensation for DP Transmitters: N/A

' Level Reference Leg: Wet Unique System Desc: Composite Avg from LTv459, LT0460 and LT0461.

Transmitters are calibrated for 6540F and 2,270 psia.

. -- = . _

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC'ERDS Parameter: RCS CHG/MU Point ID: FC 4658 Plant Spec Point-Desc: Charging Line Corrected Flow IMA Generic /Cond Desc: Primary System Charging or Makeup Flow Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: _ 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of-Sensors: 1 How Processed: Avg Sensor Locations: Charging Header Alarm / Trip Set Points: N/A-NI Detector Power Supply Cut-Off Power Level: N/A NI Detector' Power Supply

-Turn-on Power Level: N/A Instrument Failure Mode: Low L Temperature Compensation L for.DP Transmitters: Y l

Level Reference Leg: N/A i

l Unique' System Desc: Chg Pump Header Flow which feeds all 3 RCS Loops. Density correction calculated by plant computer based on temp.

,- --, , . ..-,-.._,_-,....m- . . - - _ _ . . . ___.-...._.-~,,s . .. _ - - _ . . . .. .. . _

. -= . . .

DATA POINT LIBRARY REFERENCE FILE

.Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: REAC VES LEV Point ID: LC 1603-Plant Spec Point Desc: Lowest Upper Plenum level Generic /Cond Desc: Reactor Vessel Water Level Analog / Digital: A

. Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TAF Reference Point Notes: 0% is ' ft. 1 in above TAF PROC or SEIS: PROC Number of Sensors: 2 How Processed: Lowest Sensor Locations: Within the HJTC probe below the upper support plate Alarm / Trip Set Points: Sensor Delta-T Exceeding NI Detector Power Supply Cut-Off Power Level: 'N/A NI Detector Power Supply Turn-on Power Level: N/A-Instrument failure Mode: Low I

Temperature Compensation for DP Transmitters: N/A

( Level Reference Leg: N/A Unique System Desc: RVL probes each contain 8 sensors (heated and unheated TCs). Uncovery of a sensor causes the delta-T between the sensor TCs to exceed 2000 F. Each ICCMS processor determines RVL by deduction from uncovered sensors.

._ . . . _--- . .~

DATA POINT LIBRARY REFERENCE FILE' Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: REAC VES LEV Point ID: LC 1602 Plant Spec Point Desc: Lowest Upper Head Level

' Generic /Cond Desc: Reactor Vessel Water Level Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TAF Reference Point Notes: 0% is 10 ft. 10 in, above TAF PROC or SENS: PROC Number of Sensors: 6 How Processed: Lowest Sensor Locations: Within the HJTC. probe above the upper support plate Alarm / Trip Set Points: Sensor Delta-T Exceedirg 2000 F NI Detector Power Supply.

Cut-Off Power Level: N/A NI Detector Power Supply _

Turn-on-Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A~

Unique' System Desc: RVL probes each contain 8 sensors (heated and unheated TCs). Uncovery of a sensor causes the delta-T between the sensor TCs to exceed 2000 F. Each ICCMS processor determines RVL by deduction from uncovered sensors.

DATA POINT O BRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS

-NRC ERDS Parameter: CORE FLOW Point ID: FC 0400A Plant Spec Point Desc: RCL A Flow Avg 1 MA Generic /Cond Desc: Total Reactor Coolant Flow Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 120 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SEi,S: PROC Number of Sensors: 9

-How Processed: Avg Sensor Locations: RCS Loop A Alarm / Trip Set Points: 92% tow NI. Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A

-Unique System Desc: Calc 1 Min Avg of FE0414, FE0415 and FE0416

DATA POINT LIBRARY' REFERENCE FILE

'Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS

NRC ERDS Parameter: CORE FLOW Point-ID: FC 0420A Plant Spec Point Desc: RCL B Flow Avg 1 MA Generic /Cond Desc: Total Reactor Coolant flow Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 120 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 9 How Processed: Avg Sensor Locctions: RCS Loop B Alarm / Trip Set Points: 92% Low NI Detector Power Supply

. Cut-Off Power level: N/A N1 Detector Power Supply Turn-on Power Level: ' .N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Calc 1 Min Avg of FE0424, FE0425 and FE0426

l DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 l 1

Reactor Unit: FA2 j Data feeder: PPC/SPDS NRC ERDS Parameter: CORE FLOW Point ID: FC 0440A Plant Spec Point Desc: RCL C Flow Avg 1 MA Generic /Cond Desc Total Reactor Coolant flow Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 120 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sent. ors: 9 How Processed: Avg Sensor Locations: RCS Loop C Alarm / Trip Set Points: 92% Low

! NI Detector Power Supply I

2 Cut-Of_f Power Level: N/A NI Detector-Power Supply Turn-on Power Level: N/A L Instrument Failure Mode: Low l

Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique Sys. tem Desc:

Calc 1 Min Avg of FE0434, FE0435 and FE0436 i

DATA POINT LIBRARY REFERENCE FILE Date:  : February 28, 1992 Reactor Unit:

FA2 Data Feeder: PPC/SPDS

.NRC ERDS Parameter: NI Power Range Point ID: NC 1100A Plant Spec Point Desc: Power Range Flux Avg 1 MA Generic /Cond Desc: Nuclear Instruments, Power Range Analog / Digital: A

-Enar Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 120 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS: PROC Number of Sensors: 8 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Adjacent to Reactor Vessel in NI Instrument

! Ports l

Alarm / Trip-Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A

-NI-Detector Power Supply Turn-on Power Level: N/A l-l Instrument Failure Mode: Low Temperature Compensation l for DP Transmitters: N/A l

Level Reference Leg: N/A Unique System Desc: 1 Min Avg of the scan frequency avg of NE0041, NE0042, NE0043, NE0044 Power Range Flux Channels 1 - 4. These are outputs from the Power Range NI Drawers and are the combined-output of the upper and lower detectors for-each channel.

. - . . _ _ . _ . - - ..~

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor-Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: NI INTER RNG Point ID: NE 0035 Plant Spec Point Desc: Int Range Flux Chan A Generic /Cond Desc: Nuclear Instruments, Intermediate Range Analog / Digital: A Engr Units / Dig States: AMPS Engr Units Conversion: N/A Minimum Instr Range: 1.0 E-11 Amps Maximum Instr Range: I.0 E-3 Amps Zero Point

Reference:

N/A Reference Point-Notes: N/A PROC or SENS: SENS l~ Number of Sensors: 1 l.

How Processed: N/A Sensor Locations: Excore Instrument Ports l-Alarm / Trip _ Set Points: Hi 0.99 E-6 L -NI Detector-Power Supply l Cut-Off' Power Level: N/A l NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low l

l- Temperature Compensation

_for DP Transmitters: N/A L

Level Reference Leg: N/A Unique System Desc:

R

DATA POINT. LIBRARY REFERENCE FILE Date: February 28, 1992

-~ Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC:ERDS Parameter: NI INTER RNG Point ID: NE 0036 Plant Spec Point Desc: Int Range Flux Chan B Generic /Cond Desc: Nuclear Instruments, Intermediate Range

' Analog / Digital: A Engr Units / Dig States: AMPS Engr Units Conversion: N/A Minimum Instr Range: 1.0 E-11 Amps

' Maximum Instr Range: 1.0 E-3 Amps

'Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor.Locatiors: Excore Instrument Ports Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

^

DATA POINT. LIBRARY REFERENCE FILE

Date: February. 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: NI SOURC RNG Point ID: NE 0031 Plant Spec Point Desc: Source Range Flux Chan A Generic /Cond Desc: Nuclear Instruments, Source Range Analog / Digital: A Engr Units / Dig States: CPS Engr Units Conversion: N/A Minimum Instr Range: 1.0 (CPS)

Maximum Instr Range: 1.0 E 6 (CPS)

Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Excore Instrument Ports

' Alarm / Trip Set Points: -Hi 0.9 E 5 NI Detector Power Suoply-Cut-Off Power level: Detectors de-energize when going above 10% Rx power l

l NI Detectar Power. Supply l- -Turn-on Power Level: Detectors energize at P-6 1.0 E-6 Amps Instrument Failure Mode: Low cTemperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A l ,

Unique System Dese:

1 l

~

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: NI SOURC RNG Point ID: NE 0032 Plant Spec Point Desc: Source Range Flux Chan B Generic /Cond Desc: Nuclear Instruments, Source Range Analog / Digital: A Engr Units / Dig States: CPS Engr Units Conversion: N/A Minimum Instr Range: 1.0 (CPS)

Maximum Instr Range: 1.0 E 6 (CPS)

Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: I How Processed: N/A Sensor Locations: Excore Instrument Ports Alarm / Trip Set Points: N/A ..

NI Detector Power Suppt Cut-Off-Power Level: Detectors de-energize when going above 10% Rx power NI Detector Power Supply Turn-on Power Level: Detectors energize at P-6 1.0 E-6 Amps Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference- Leg: N/A Unique System Desc:

.1 DATA POINT LIBRARY REFERENCE FILE P

Date: February 28, 1992 Reactor Unit: FA2-Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Level A Point ID: LT 0477 Plant Spec Point Desc: SG A Wide Range Level Generic /Cond Desc: SG A Water Level Analog / Digital:. A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 ZeroHPoint

Reference:

TUBSHT Reference Point Notes: 0% corresponds to the TUBSHT and 70%

corresponds to the top of tube bundle.

PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Steam Generator A Alarm / Trip Set Points: Lo 43%, Hi 55%

NI Detector Power Supply Cut-Off Power Level: N/A-NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DF Transmitters: N/A Level Reference Leg: Wet Unique System Dest: Transmitters are cold calibrated.

-DATA POINT LIBRARY REFERENCE FILE Date:- February 28, 1992 Reactor Unit: -FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Level B Point ID: LT 0487 Plant Spec Point Desc: SG B Wide Range Level Generic /Cond Desc: SG B Water Level .!

Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 0% corresponds to the TUBSHT and 70%

corresponds to the top of tube bundle.

PROC or SENS: SENS

Number of Sensors
1 How-Processed: N/A Sensar. Locations: Steam Generator B Alarm / Trip _ Set Points: -Lo 43%, Hi 55%

NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply '

Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters:- N/A LevelLReference leg: Wet Unique System Desc: Transmitters are cold calibrated.

DATA POINT LIBRARY REFEP.ENCE FILE

-Date: February 28, 1992 Reactor Unit: -FA2 Data Feeder: PPC/SPDS NRC'ERDS Parameter: SG Level C Point ID: LT 0497 Plant Spec Point Desc:  ;SG C-Wide Range Level Generic /Cond Desc: SG C Water Level a

Analog / Digital: A Engr Units / Dig States:

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

TUBSHT Reference Point Notes: 0% corresponds to the TUBSHT and 70%

corresponds to the tcp of tube bundle, PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Steam Generator C Alarm / Trip Set-Points: Lo 43%, Hi 55%

NI Detector Power Supply Cut-Off-. Power level: N/A NI Detector. Power Supply Turn-on Power. Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: Wet Unique System Desc: Transmitters are cold calibrated.

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: -FA2 Data Feeder:- PPC/SPDS NRC ERDS Parameter: SG Pressure A Point ID: PC 2300 A Plant Spec Point Desc: SG A Pressure Avg 1 MA Generic /Cond Desc: SG A Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A "inimum lastr Range: 0 Maximum Instr Range: 1200 Zero Point

Reference:

N/A

. Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 3 How Processed:

Redundant Sensor Algorithm Avg Sensor Locations: Steam Generator A Alarm / Trip Set Points: Lo 600, Hi 1025 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply L Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation

.for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: 1 Min Avg of the scan frequency Avg of PT0474, c PT0475, PT0476, SG A Outlet Pressure Channels l 1, 2 and 3 l

b DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit:- FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Pressure B Point ID:- PC 2301 A Plant Spec Point Desc: SG B Pressure Avg 1 MA Generic /Cond Desc: SG B Pressure Analog / Digital: A-Engr _ Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1200

Zero Point

Reference:

N/A Reference Point: Notes: N/A PROC or.SENS: PROC

(:

l Number of Sensors: 3 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Steam Generator B

~

Alarm / Trip Set Points: Lo 600, Hi.'025 NI Detector Power Supply

. Cut-Off Power Level: N/A L

~

NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low-

. Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:- 1 Min Avg of the scan frequency, Avg of PT0484, PT0485, PT0486, SG B -Outlet Pressure Channels 1, 2 and 3

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: SG Pressure C Point ID: PC 2302 A Plant Spec Point Desc: SG C Pressure Avg 1 MA Generic /Cond Desc: SG C Pressure Analog / Digital: A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1200 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 3 L

How Processed: Redundant Sensor Algorithm Avg

. Sensor. Locations: Steam Generator C 4

Alarm / Trip Set Points: Lo 600, Hi 1025 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A

( Level Reference leg: N/A Unique System Desc: 1 Min Avg of the scan frequency Avg of PT0494, PT0495, PT0496, SG C Outlet Pressure Channels 1, 2 and 3 1

DATA. POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2-Data Feeder: PPC/SPDS NRC ERDS Parameter: MN FD FL A Point ID: FC 4655 Plant _ Spec Point Desc: SG A Main FW Corr Flow 1 MA Generic /Cond Desc: SG A Main FW Flew Analog / Digital: A Engr Units / Dig States: KLB/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 5000 Zero Point

Reference:

0 Reference Point Notes: N/A PROC.or SENS: PROC Number.of Sensors: 2 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Main FW Line to SG A Alarm / Trip Set Points: Lo -2, Hi 5000 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on' Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Feference Leg: N/A Unique System Desc: 1 Min Avg density corrected SG A Main Feedwater Flow. Density correction calculated based on FW Temp. Sensors are FE4768 and FE4778.

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: MN FD FL B Point ID: FC 4656 Plant Spec Point.Desc: SG B Main FW Corr Flow 1 MA Generic /Cond Desc: SG A Main FW Flow

- Analog / Digital: A Engr Units / Dig States: KLB/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 5000 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 2 How Processed:

Redundant Sensor Algorithm Avg Sensor Locations: Main FW Line to SG B Alarm / Trip Set Points: Lo -2, Hi 5000 ,

hl Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: ' N/A L

Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A l.

Level Reference Leg: N/A l

l_ Unique System Desc: 1 Min Avg density corrected SG B Main Density correction calculated Feedwater Flow.

based on FW Temp. Sensors are FE4868 and FE4878.

i

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: MN FD FL C Point ID: FC 4657 Plant Spec. Point Desc: SG C Main FW Corr Flow 1 MA Generic /Cond Desc: SG C Main FW Flow

' Analog / Digital: A Engr Units / Dig States: KLB/HR Engr Units Conversion: N/A Minimum Instr' Range: 0 Maximum Instr Range: 5000 Zero. Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: PROC

. Number of Sensors: 2 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Main FW Line to SG C Alarm / Trip Set Points: Hi 5000 NI Detector. Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: 1 Min Avg density corrected SG C Main Feedwater Flow. Density correction calculated based on FW Temp. Sensors are FE4968 and FE4978.

l DATA POINT LIBRARY REFERENCE FILE.

Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: AX FD FL A Point ID: FT 3229A Plant Spec Point Desc: Aux FW Flow to SG A Generic /Cond Desc: SG A Aux /' d Flow

- Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr. Range: 0 Maximum' Instr Range: 800 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS i

Number of Sensors: 1 How Processed: N/A Sensor Locations: Aux FW Line to SG A Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI DetectorL Power Supply-

-Turn-on Power Level: N/A Instrument Failure Mode: Low

-Tu.aperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Dest:

= < w

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 ,

1 Reactor. Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: AX FD FL B Point ID: FT 3229B Plant Spec Point Desc: Aux FW Flow to SG B LGeneric/Cond Desc: SG B Aux FW Flow Analog / Digital: A Engr Units / Dig States: GPM Engr Units ~ Conversion: N/A Minimum Instr Range: 0-Maximum Instr Range: 800 Zero Point

Reference:

0

~ Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: I How Processed: N/A SensorLLocations: Aux FW Line to SG B Alarm / Trip Set Points: N/A NI Detector Power Supply-Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation

-for.DP Transmitters: N/A Level Reference Leg: N/A

' Unique System Desc:

, - ,- . . . . _ -- . , , . - . . _ -._ -- . _ _ . . _ , - , - - . . . . . , _ - , _ - ~ . . .

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPCf .iPDS NRC ERDS Parameter: AX FD FL C Point ID: FT 3229C Plant Spec Point Desc: Aux FW Flow to SG C Generic /Cond Desc; SG C Aux FW Flow Analog / Digital: A Engr Units / Dig States: GPM Engr. Units Conversion: N/A Minimum Instr Range: 0 Maximum-Instr Range: 800 Zero Point

Reference:

0 Reference Point Notes: N/A

' PROC or SENS:

SENS Number of Sensors: 1 u

How Processed:

N/A Sensor Locations: Aux FW Line to SG C Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE flLE i

Date: February 28, 1992 l 1

Reactor Unit: FA2 l Data feeder: PPC/SPDS NRC ERDS Parameter: LP Si flow Point ID: FE 0605A Plant Spec Point Desc: RHR Train A Flow Generic /Cond Desc: Low Pressure $1 Flow - Train A Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion:- N/A Minimum Instr Range: 0 Maximum Instr Range: 4250 Zero Foint

Reference:

0 Reference Point Hotes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Downstream of the Train A RHR Hx Alarm / Trip Set Points: Hi 5000 NI Detector Power Supply Cut-Off Power Level: N/A

, NI Detector Power Supply l Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation l for DP Transmitters: N/A Level-Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 2c, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: LP SI Flow ,

1 Point ID: FE 06058 Plant Spec Point Desc: RHR Train B flow Generic /Cond Desc: Low Pressure Si flow - Train B Analog /Digitt A Engr Units / Dig States: GPM Engr Units Conversion: N/A ,

Minimum Instr Range:- 0 Maximum Instr Range: 4250 Zero Point

Reference:

0 Reference' Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A -

Sensor Locations: Downstream of the Train.B RHR lix Alarm / Trip Set Points:. Hi 5000 N1 Detector Power Supply Cut-Off Power Level: N/A i NI Detector Power Supply L Turn-on Power Lovel: N/A i

Instrument Failure Mode: Low Temperature Compensation for DP Trans9itters: N/A Level Reference Leg: N/A Unique System Desc:

l

DATA PolNT LIBRARY REFERENCE f!LE ,

Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: HP SI Flow Point ID: FT 0943 Plant Spec Point Desc: 51 Header to Bli Generic /Cond Desc: HP Si flow Analog / Digital: A Engr Units, Dig States: GPM Engr Units Conversion: N/A liinimum Instr Range: 0 Maximum instr Range: 1000 Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: HP SI Header to BIT Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power level: N/A Instrument failure Mode: Low Temperature Compensation l for DP Transmitters: N/A Level Reference Leg: N/A

, Unique System Desc:

l Y'

____m..

DATA POINT LIBRARY. REFERENCE f!LE Date: February 28, 1992 Reactor Unit: TA2 Data feeder: PPC/SPDS NRC ERDS Parameter: BWST Level Point ID: LT 0501 Plant Spec Point Desc: RWST Level Channel 1 Generic /Cond Dese: Borated Water Storage Tank Level Analog / Digital: A Engr Units / Dig States: Feet Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 40 t

Zero Point

Reference:

TNKBOT Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations:- RWST Alarm / Trip Set Points: Lo 12.6 N1. Detector Power Supply

-Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A-Level Reference Leg: N/A Unique System Desc: One of two channels

. _ . . . _ _ . . . _ _ . ._. _. . _ . _ . _ _ . . . , . - - , _ . _ _ . . - . _ . . . _ , , . . _ . . . ~ _ _ - ._

_ . . _ = _ . ._ _ . _ _ _--_.__ _ ___. ._ __ _ _ . __.____ _. __ ._____ _

. DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 i

Data feeder: PPC/SPDS NRC ERDS Parameter: CTMNT Pressure Point ID: PC 3700 Plant Spec Point Desc: Highest CTMT Pressure Generic /Cond Desc: Containment Pressure Analog / Digital: A -

Engr Units / Dig States: -PSIG Engr Units Conversion: N/A Minimum Instr Range: -5

-Maximum Instr Range: 22S Zero Point

Reference:

0 Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 2 How Processed: Algorithm Max Sensor Locations: CTMT Alarm / Trip Set Points: Hi 4.0, Hi Hi 16.2, Hi Hi Hi 27.0 NI Detector Power Supply Cut-Off Power Level: N/A NI Detecto* Power Supply r- Turn-on Power Level: N/A -

Instrumtat Failure Mode: Low Temperature Compensetion for DP Transmitters: N/A ,

[ Level Reference Leg: N/A Unique System Desc: Highest containment pressure calculated from P10950Y and Z, containment pressure extended range.

DATA POINT LIBRARY REFERENCE flLE -

Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC EROS Parameter: CTMNT SMP R Point ID: LC 1501 Plant Spec Point Desc: CTMT Sump Level Avg Generic /Cond Desc: Containment Sump Level .

Analog / Digital: A Engr Units / Dig States: Feet Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 10 Zero Point

Reference:

. Bottom of Sump Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 2 How Processed: Redundant Sensor Algorithm Avg Sensor Locations: Containment Sump Alarm / Trip Set Points: Lo 1.0, Hi 5.0 NI Detector Power Supply Cut-Off Power level: N/A NI Detector Power Supply Turn-on Power Level: N/A l Instrument failure Mode: Low ,

Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A.

Unique System Desc: Containment Sump Lovel Avg of LT 3594A and LT 35948 l

, ,. . . - - . - , , , . . - - , _ - - - , . . . . _ . , , . - . - - , . . - . -... -..-. - - - ..-.._i--.-

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: CTMNT TEMP Point 10: TE-3187E Plant Spec Point Desc: ClMT Cooler D Air Inlet Temp Generic /Cond Dese: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum _ Instr Range: -150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: CTMT Cooler D Air Inlet Alarm / Trip Set Points: Hi 130 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique Systen Desc:

I

1 l

, DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FA2 -

Data feeder: PPC/SPDS NRC ERDS Parameter: CTMNT TEMP Point ID: TE 3187f j Plant Spec Point Desc: CTHT Cooler C Air Inlet Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0

- Haximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of-Sensors: 1

- How Processed: N/A Sensor Locations: CTMT Cooler C Air inlet Alarm / Trip Set Points: Hi 130 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A

+

Instrument failure Mode: Low Temnerature-Compensation for DP. Transmitters: N/A Level Reference Leg: N/A ilnique-System Desc:

V l

-w - -- n. 4w -y w- gr eer .e.se,, w ~,me-wwwe-y-,.-e ,r ye<-e-~,egew e -v e .w ww e% g . weme m y , s,,r w,7,,y<.w ,,=w, mgyye y- r --r-v v, vy v..,--eve *v= t

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: CTMNT TEMP Point 10: TE 3187G Plant Spec Point Desc: CTMT Cooler B Air inlet Temp Generic /Cond Desc: Containment Temperature i

Analog / Digital:- A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point.Hotes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: CTMT Cooler B Air Inlet Alarm / Trip Set Points: Hi 130 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

. _ _ . . . . _ _ . - . _ - _ . . _ _ . _ _ _ . - . ~ _ - - _ . _ _ ._

DATA POINT LIBRARY REFERENCE FILE i Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPUSPDS NRC ERDS Parameter: CTMNT TEMP ,

Point-ID: TE 3187H Plant Spec Point Desc: CTMT Cooler A Air Inlet Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A Engr Units / Dig States: DEGF 1 Engr Units Conversion:~ N/A Minimum Instr Range: 0 Maximum-Instr Range: 150 Zero Peint R1ference: N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: CTMT Cooler A Air Inlet Alarm / Trip Set Points: Hi 130

~ NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level:- N/A Instrument failure Mode; i.ow Tempirature Compensation for LP Transmitters: _N/A Level Reference Leg: N/A Unique System Desc:

l DATA POINT LIBRARY REFERENCE f!LE Date: february 28, 1992 Reactor Unit: FA2 ,

Data feeder: PPC/SPDS NRC ERDS Parameter: CTMNT TEMP Point ID: TE 31871 Plant Spec Point Desc: CTHT Dome Inside Air Temp Generic /Cond Desc: Containment Temperature Analog / Digital: A l

Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range:. 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Containment Dome Alarm / Trip Set Points: Hi 130 NI Detector Power Supply Cut-Off Pcmar Level: N/A NI Detector Power Supply

  • Turn-on Power Level: N/A Instrument Failure Mode: Low ,

. Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

i

, .-.,,--, , -..,-. -- --.. , , , , . , . . . - , . . . . - . . _ , . - , , , . - - . . - - . . . . - . - - , - - - - - . ~ - . .

i l

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: RCS LTDN RAD Point 10: RE 0050 Plant Spec Point Desc: Gross failed fuel Detector Generic /Cond Dese- Rad Level of RCS Letdown Line Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A ,

Minimum Instr Range: 10 Maximum Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Emergency Sample Room l Alarm / Trip Set Points: Mi 11,000 l NI Detector Power Supply i Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

t

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: CTHT RAD Point ID: RC 3702 Plant Spec Point Dese: Highest Hi level CTMT Radiation Generic /Cond Desc: Radiation level in the Containment Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 1.0 Maximum Instr Range: 1.0 E 7 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS- PROC Number of Sensors: 2 How Processed: Algorithm Max Sensor Locations: Containment Alarm / Trip Set Points: 10.0-NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A

' Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: RC 3702 selects the highest output of R27A or R278.

Q, . u :_.,...__.-_. .x _ . _ _ _ _ __ _ - - - . . _ . . . _

DATA POINT LIBRARY REFERENCE file l Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: COND AE RAD Point ID: RE 0015C Plant Spec Point Desc: SJAE Exhaust High Range Monitor Generic /Cond Dest: Condenser Air Ejector Radioactivity Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor locations: Steam Jet Air Ejector _

Alarm / Trip Set Points: Hi 2.8 E-2 N1 Detector Power Supply a Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Ir 'rument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Steam jet air ejector exhaust high range radiation monitor

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 0014 i

Plant Spec Point Desc: Vent Gas Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SEliS Number of Sensors: 1 How Processed: N/A Sensor Locations: Plant Vent Stack Alarm / Trip Set Points: Hi 17,000 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference leg: N/A Unique System Desc:

i

(-

i.

DATA POINT LIBRARY REFERENCE FILE r Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD I Point ID: RE 0021  ;

Plant Spec Point Desc: Vent Air Particle Monitor Generic /Cond Desc: Radioactivity of Released Cases -

Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A Minimum Instr Pange: 10 Maximum. Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A u.a r Locations: Auxiliary Building Ah. m/ Trip Set Points: Hi 1200 N1 Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A-Instrument Failure Mode: Low Temperature Compensation for DP Transmitters:_ N/A ,

Level Reference Leg: N/A Unique System Desc:

. _ - - , . . ~ . . - . _ _ _ . _ . _ _ . _ - - _ . _ . _ . , . _ . _ . - - _ _ _ . . _ _ - - . _ - _ _ . _ _ , . . . _ . _ . . _

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 0022 Plant Spec Point Desc: Vent Gas Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: CPM Engr Units Conversion: N/A ,

Minimum Instr _ Range: 10 Maximum Instr Ranga: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Alarm / Trip Set Points: Hi 156 N1 Detector Power Supply

' Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A' Unique S: > tem Desc:

l

!' r l

. . - . . - _ . . _ . . , _ . , _ . . . . . . . . . _ _ _ . . , _ , , . _ . . _ . ~ . _ _ _ _ . - , . . . - - . , - . . . _ - . _ ,

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RG 00298 - NG Plarit Spec Point Desc: Plant Vent Stack High Range Noble Gas Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: uC1/ML Engr Units Conversion: N/A Minimum Instr Range. 1.10 E-7 Maximum Instr Range: 1.44 E 5 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors: 3 How Processed: Algorithm selects from low, mid, and high range detectors

. Sensor locations: Plant Vent Stack 1

l Alarm / Trip Set Points: 4.44 E-4 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply .

Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE flLE i

I Date: february 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 0029B - 12 Plant Spec Point Desc: Plant Vent Stack lodine - 131  ;

Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: uCI/ML Engr Units Conversion: N/A ,

Minimum Instr Range: 1.40 E-ll Maximum. Instr Range: 4.00 E-6 Zero Point

Reference:

N/A ,

Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sansor Locations: Control Room Penthouse / Plant Vent Stack Alarm / Trip Set Points: 1.0 E-6 N1 Detector Power Supply Cut-Off-Power Level: N/A NI Detector Power Supply Turn-on_ Power Level: N/A ,

Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINl LIBRARY REFERENCE FILE Date: February 20, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 0060A Plant Spec Point Desc: SG A Atmospheric Relief Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Roof Alarm / Trip Set Points: 3.50 E-2 NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

I

DATA POINT LIBRARY REFERENCE FILE Date: Februsry 28, 1992 Reactor Unit: fat .

Data feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 0060B Plant Spec Point Desc: CS B Atmospheric Relief Monito.-

Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000 I

Zero Point

Reference:

N/A Reference Point Notea: N/A PROC or SENS* SENS Number of Sensors: 1 Hod Processed: N/A Sensor Locations: Auxiliary Building Roof f

Alarm / Trip Set Points: 3.50 E-2 NI Detector Power Supply Cut-Off Power Level: N/ '.

NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation

! - for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

w ,- - - - - r - - -,, y ,-w,,-, ,,, ,, .w-- - , - , y--.,---.e.- ,c--- - , , , ,,gw., , y-,-,-.-+-.y,.,. mv,e, , --w.- , - ----e.,-, y g y

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point 10: RE 0060C Plant Spec Point Desc: SG C Atmospheric Relief Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: R/liR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1,000

-Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Roof Alarm / Trip Set Points: 3.50 E-2

-NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low

Temperature Compensation for DP Transmitters
N/A Level Reference Leg: N/A Unique System Desc:

l i

DATA POINT LIBRARY REFERENCE flLE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: EFF GAS RAD Point ID: RE 00600 Plant Spec Point Desc: Aux feed Turbine Exhaust Monitor Generic /Cond Desc: Radioactivity of Released Gases Analog / Digital: A Engr Units / Dig States: R/HR >

Engr Units' Conversion: N/A j Minimum Instr Range: 0 ,

Maximum Instr Range:- 1,000 Zero Point

Reference:

N/A-Reference Point Notes: N/A-PROC or SENS; SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Auxiliary Building Roof Alarm / Trip Set Points: 3.50 E-2 NI Detector Power Supply-Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A l Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A-Level Reference Leg: N/A Unique System Desc:

l I

DATA POINT LIBRARY REFERENCE f!LE Date: February 28, 1992 Reactor Unit: FA2 ,

Data Feeder: PPC/SPDS NRC ERDS Parameter: MAIN SL A Point-ID: RE 0070A Plant Spec Point Desc: N16 Leak Detection System S/G A Generic /Cond Desc: Stm Gen A Steam Line Rad Level ,

Analog / Digital: A Engr Units / Dig States: GPD Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Main Steam Line A Alarm / Trip Set Points: 10 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2

-Data Feeder: PPC/SPDS NRC ERDS Parameter: MAIN SL B Point ID: RE 00708 Plant Spec Point Desc: N16 Leak Detection System S/G B Generic /Cond Desc: Stm Gen B Steam Line Rad Level Analog / Digital: A Engr Units / Dig States: GPD Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sa ors: 1 How Processed: N/A Sensor Locations: Main Steam Line B Alarm / Trip Set Points: 10 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

j

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: MAIN SL C Point ID: RE 0070C Plant Spec Point Desc: N16 Leak Detection System S/G C Generic /Cond Desc: Stm Gen C Steam Line Rad Level Analog / Digital: A Engr Units / Dig States: GPD Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 1,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Main Steam Line C Alarm / Trip Set Points: 10 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: EFF LIQ RAD Point 10: RE 0018 Plant Spec Point Desc: Waste Disposal liquid Monitor Generic /Cond Desc: EFF LIQ RAD Analog / Digital: A Engr Units / Dig States:

CPM Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Instr Range: 10 E 6 4 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Liquid Effluent Line _

Alarm / Trip Set Points: Variable determined by ODCM NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Dest:

DATA POINT LIBP.ARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: PPC/SPDS NRC ERDS Parameter: EFF LIQ RAD Point ID: RE 0023B Plant Spec Point Desc: SG Blowdown Treatment Monitor Generic /Cond Desc: Radioactivity of Released Liquids Analog / Digital: A Engr Units / Dig States:

CPM Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Instr Range: 1.0 E 6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: SG Blowdown Effluent Line _

Alarm / Trip Set Points: 1,000 NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

I 1

DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 y Reacf. Unit: FA2 la Feeder: PPC/SPDS nin ERDS. Parameter:- WIND SPEED Point ID: WS35FT t Spec Point.Desc: Wind Speed 35' Elev tond Desc: Wir.d Speed at Reactor Site

'igital: .A

.r - mits/ Dig States: MPH Eas t ..ts Conversion: h'/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

N/A

' Reference Point Notes: N/A PROC or SENS: SENS

  • t aber of Sensors: 1 How Processed: N/A Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A' NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply l Turn on Power Level: N/A j;

i instrument Failure Mode: Low l

l Temperature Compensation

l. for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Met tower base is at 182 feet MS'.

. - - , . . - _ . - . . . . _ - . . - . _ . . _ _ . ., _ . , _ . _ _ _ , , , = _ -_ . - , . -_

. ~.- . . _ - . .-... . .. . .. . -. .--- .. -. . - - _

DATA POINT LIBRARV t4FERENCE FILE- i

.0 ate: February 28, 1992 Reactor Unit: FA2 Dat=. Feeder: PPC/SPDS NRC.ERDS Parameter: WIND SPEED

- Point:ID: WS150FT Plant Spec Point Desc: W nd Speed 150' Elev Generic /Cond Desc: Wind Speed at Reactor Site Analog / Digital: A Engr Units / Dig States: MPH Engr Units-Conversion: -N/A Minimum Instr Range:- 0 Maximum Instr Range: 150 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A

. Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A '

NI Detector Power Supply

. Turn-on Power Level
N/A l

L Instrument failure Mode: Low Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A l Unique System Desc: Met towe< base-is at 182 feet MSL i

I

, - , . .-.-,.4 e n y . ,c-e-v = . . _w, y -4,--

l DAT/. POINT LIBRARY REFERENCE FILE Date:- February 28, 1992 Reactor Unit: FA2 Data Feeder: PPC/SPDS NRC ERDS Parameter: WIND DIR Point 10: WD35FT Plant Spec Point Desc: Wind Direction 35' Elev Generic /Cond Desc: Wind Direction at Reactor Site Analog / Digital: A Engr Unitt/ Dig States: DEGFR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 540 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Primary Met Tower

' Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A i

!- Instrument Failure Mode: As is Temperature Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Met tower base slab is at 182 feet M. . Wind direction is "from."

. , - ,_ __ . . . _ , = , .-.~--,.-%, - --,4 - - -

.- 7 DATA POINT-LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2 Data feeder: .PPC/SPDS NRC ERDS Parameter: WIND DIR Point ID: WD150FT Plant Spec Point Desc: Wind Direction 150' Elev i

Generic /Cond Desc: Wind Direction at Reactor Site Analog / Digital: A Engr Units / Dig States: DEGFR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 540 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 1 How Processed: N/A Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A NI Detector Power Supply Cut-Off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: As is Temperature. Compensation for DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Met tower base slab is at 182 feet MSL. Wind direction is "from."

l l

._ .. _ _ _ . . . . .._ . _ . _ _ _ . . ._. . . . _ _ _ _ a

DATA POINT LIBRARY REFERENCE FILE ,

i Date: February 28, 1992 l Reactor Unit: FA2 Data Feeder: PPC/SPDS WRC ERDS Parameter:

- STAB CLASS Point ID: STCLASS Plant Spec Point Desc: Stability Class Delta Temp Generic /Cond Desc: -Air Stability at Reactor Site Analog / Digital: A Engr Units / Dig States: DEGF Engr Units-Conversion: N/A Minimum' Instr Range: -100F Maximum Instr' Range: 4200F Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS Number of Sensors: 2 How Processed: N/A Sensor Locations: Primary Met Tower Alarm / Trip Set Points: N/A-NI Detector Power Supply Cut-Off Power Level: N/A NI Detector Power Supply.

Turn-on Pcwer Level: N/A Instrument Failure Mode: Low Temperature Compensation

_for DP Transmitters:

N/A Level Reference Leg: N/A Unique System Dest:: Temp Difference Between 35 feet and 200 feet

r DATA POINT LIBRARY REFERENCE FILE Date: February 28, 1992 Reactor Unit: FA2-4 Data Feeder:. PPC/SPDS NRC ERDS Parameter:- N/A

~

Point ID: FT 2879 Plant Spec Point Desc: Plant Vent Stack Flow

, Generic /Cond Desc: N/A 4

Analog / Digital:.- A

- Engr-Units / Dig States: CFM Engr Units Conversion: N/A i Minimum Instr Range: 0 a

Maximum Instr Range: 170,000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: SENS

Number of Sensors
1 How Processed: .N/A Sensor Locations: Plant Vent Stack

.' A'l arm / Trip Set Points: N/A

. NI Detector. Power Supply Cut-Off Power Level: N/A NI Detector Power Supply

. Turn-on Power Level: N/A Instrument Failure Mode: Low Temperature Compensation for DP Transmitters: N/A

' Level Reference Leg:. N/A Unique System Desc:

i

_ __. _ . _ , ~ . ~_ . _ . . . . _ . _ . _ . . . .

. .