ML20078F092
| ML20078F092 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 01/27/1995 |
| From: | ENTERGY OPERATIONS, INC. |
| To: | |
| Shared Package | |
| ML20078F090 | List: |
| References | |
| NUDOCS 9502010314 | |
| Download: ML20078F092 (4) | |
Text
-
DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel assembly containing a maximum of 236 fuel rods cicd with Zircaloy-4. Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 grams uranium. The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235. Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.1 weight percent U-235. I CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element assemblies.
5.4 REACTOR COOLANT SYSTEM f
DESIGN PRESSURE AND TEMPERATURE
'5.4.1 The Reactor Coolant System is designed and shall be maintained:
~
- a. In accordance with the code requirements specified in Section 5.2 of the FSAR with allowance for normal degradation pursuant of the applicable Surveillance Requirements,
- b. For a pressure of 2500 psia, and
- c. For a temperature of 650'F, except for the pressurizer and surge line which is 700*F.
VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11,800
+600, -0 cubic feet- at a nominal T,yg of 582.1*F.
5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.
l WATERFORD - UNIT 3 5-5 AMENDMENT NO. 7,##
9502010314 950127 PDR ADOCK 050003B2 P PDR
(---
1 9
- y I ~ '.
c NPF-38-163 ATTACHMENT II
,+ . - , . _ _ - - .-- .. -- . -. .- . - . .
31 DESIGN FEATlRES i
'5.3 REACTOR CORE i FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel. assembly containing a maximum of 236 fuel rods clad with Zircaloy 4. Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 1830 grams uranium. l .,
The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235.
Reload fuel shall be similar in physical design to the initial core loadingg-and Assemblies .
shall have a maximum enrichment of Art 4.9 weight percent U-235 provided they contain sufficient fixed poisons to meet the final storage requirements described in section 5.6.
CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element f assemblies.
5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE
)
5.4.1 The Reactor Coolant System is designed and shall be maintained- !
- a. In accordance with the code requirements specified in Section 5.2 of the FSAR l with allowance for normal degradation pursuant of the applicable Surveillance j Requirements, j l
- b. For a pressure of 2500 psia, and 1 i
- c. For a temperature of 650F, except for the pressurizer and surge line which is I l
700*F.
. l VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11.800 +600, -0 cubic feet at a nominal Tavg of 582.1*F. i 5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.
WATERFORD - UNIT 3 55 AMENDMENT NO.,44
.a '
i NPF-38-163 ATTACHMENT III