ML091520338

From kanterella
Revision as of 22:06, 11 July 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
NRC Region III, Initial License Exam, Job Performance Measure, JPM: RO System H, Title: Set RIA-1113 Waste Gas Discharge Monitor Hi Alarm Setpoint
ML091520338
Person / Time
Site: Palisades Entergy icon.png
Issue date: 07/07/2008
From:
NRC/RGN-III
To:
Entergy Nuclear Palisades
Shared Package
ML082200311 List:
References
Download: ML091520338 (10)


Text

NRC REGION III INITIAL LICENSE EXAM JOB PERFORMANCE MEASURE

JPM: RO SYSTEM h TITLE: SET RIA-1113 WASTE GAS DISCHARGE MONITOR HI ALARM SETPOINT

CANDIDATE: _______________

__________________

____________

EXAMINER: _____________________________________________

JPM: RO SYSTEM h JOB PERFORMANCE MEASURE DATA PAGE Task: Adjust RIA-1113 Waste Gas Di scharge Monitor Hi Alarm Setpoint

Alternate Path: NO

Facility JPM #: PL-OPS-RMS-001J

K/A: 073A4.01 Importance: RO: 3.9 SRO: 3.9

K/A Statement: Ability to manual ly operate and/or monitor in the control room: effluent release Task Standard: Waste Gas Discharge Monitor,RIA-1113, high alarm setpoint adjusted to 8585 CPM

Preferred Evaluation Location: Simulator __X__ In Plant _____

Preferred Evaluation Method: Perform __X__ Simulate _____

References:

SOP-38, Gaseous Waste Monitoring System

Validation Time: 10 minutes Time Critical: NO

Candidate: _________

________________________

____________________

Time Start: ________ Time Finish: ________

Performance Time: ________ minutes

Performance Rating: SAT______ UNSAT ______

Comments:

Examiner: _________

______________________ Date: ______________

Signature PALISADES NUCLEAR PLANT Page 2 of 10 JULY 2008 JPM: RO SYSTEM h EXAMINER COPY ONLY Tools/Equipment/Procedures Needed:

SOP-38, Gaseous Waste Monitoring System Release Order, Form HP 6.6-3 (batch card)

Safety glasses (optional)

Fire Retardant Class 1 Electr ical Safety Shirt (optional)

Also see Simulator Operator Instructions (last page of this document).

READ TO CANDIDATE

DIRECTION TO CANDIDATE:

I will explain the initial conditions, and state the task to be per formed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

  • Waste Gas Discharge Monitor, RIA-1113 Batch Card background reading = 95 CPM.
  • Waste Gas Discharge Monitor, RIA-1113 Batch Card Release Limit = 8500 CPM
  • Waste Gas Discharge Monitor, RIA-1113 Batch Card "High Alarm Setpoint" = 8600 CPM.
  • Release Order, Form HP 6.6-3 (batch card) is available.
  • Breaker 34 on Y-01 is closed.
  • RIA-1113 has been verified aligned for service per Attachment 5, Checklist 38, "Gaseous Process Radiation Monitors System Checklist"
  • A check source has been completed on RIA-1113 with a reading of 620000 CPM.

INITIATING CUES:

  • The CRS directs you to set up Waste Gas Discharge Monitor, RIA-1113 High Alarm Setpoint using SOP-38 Section 7.3.6 to a setpoint of 8600 cpm.

PALISADES NUCLEAR PLANT Page 3 of 10 JULY 2008 JPM: RO SYSTEM h Proc. Step TASK ELEMENT 1 STANDARD Grade n/a Locate SOP-38, Section 7.3.6 SOP-38, Section 7.3.6 located

S U Comment:

Evaluator provides candidate with a Work ing Copy of SOP-38 and Form HP 6.6-3

Proc. Step TASK ELEMENT 2 STANDARD Grade7.3.6a READ the "As Found" count rate on RIA-1113, Waste Gas Discharge Monitor 9.5 x 10 1 "As Found" count rate read on RIA-1113 (given in initial conditions)

S U Comment:

Proc. Step TASK ELEMENT 3 STANDARD Grade7.3.6b PULL RIA-1113 out from the panel about (6) inches to access the control buttons RIA-1113 pulled out from panel about 6 inches.

S U Comment:

NOTE: Operator may don safety gl asses and a Fire Retardant Class 1 electrical safety shirt, although this is not required.

Proc. Step TASK ELEMENT 4 STANDARD Grade7.3.6c VERIFY the Function switch is on "0." (seen on the right side of the switch)

Verifies right side of Function Switch is set to "0". S U Comment:

PALISADES NUCLEAR PLANT Page 4 of 10 JULY 2008 JPM: RO SYSTEM h Proc. Step TASK ELEMENT 5 STANDARD Grade7.3.6d PRESS Enter button to display the High Alarm setpoint.

Enter button pressed and one digit blinking.

S U Comment: NOTE: Control buttons and Function switch ar e located on the right, inside RIA-1113. The control buttons are labeled Digit, Value, and Enter.

CRITICAL STEP

Proc. Step TASK ELEMENT 6 STANDARD Grade7.3.6e SET the High Alarm Setpoint per Form HP 6.6-3, WGDT Release Authorization, by performing the following as necessary: IF changing the digit value, THEN PRESS the Value pushbutton until the desired value for that digit is displayed IF selecting another digit, THEN PRESS the Digit pushbutton "Digit" and "Value" push buttons used to change the trip setpoint to 8.6 x 10 3 (8600) CPM value.

S U Comment:

CRITICAL STEP

Proc. Step TASK ELEMENT 7 STANDARD Grade7.3.6f WHEN entire display indicates the desired Setpoint, THEN PRESS the Enter pushbutton Enter pushbutton pressed

S U Comment:

CRITICAL STEP

PALISADES NUCLEAR PLANT Page 5 of 10 JULY 2008 JPM: RO SYSTEM h Proc. Step TASK ELEMENT 8 STANDARD Grade7.3.6g PUSH the monitor back into panel.

Monitor pushed back into panel.

S U Comment:

Proc. Step TASK ELEMENT 9 STANDARD Grade7.3.6h PRESS High Alarm pushbutton on the front of RIA-1113 to verify High Alarm Setpoint is correct.

High Alarm push button pressed and 8.6 x 10 3 (8600) CPM trip setpoint verified.

S U Comment:

Proc. Step TASK ELEMENT 10 STANDARD Grade7.3.6i PRESS Alarm Ack pushbutton to clear any alarms that may have annunciated.

Alarms clear.

S U Comment:

Proc. Step TASK ELEMENT 11 STANDARD Grade7.3.6j VERIFY EK-1364, "Gaseous Waste Monitoring Hi Radiation" annunciator is CLEAR. Alarm clear.

S U Comment:

PALISADES NUCLEAR PLANT Page 6 of 10 JULY 2008 JPM: RO SYSTEM h PALISADES NUCLEAR PLANT Page 7 of 10 JULY 2008 Proc. Step TASK ELEMENT 12 STANDARD Grade7.3.6k NOTIFY RETS/REMP representative of the new High Alarm Setpoint.

Step not necessary, setpoint raised for batch release. S U Comment:

NOTE: Evaluator: If operator starts to contact RETS/REMP, STATE: they are aware that the High Alarm Setpoint has been raised for the batch release.

Proc. Step TASK ELEMENT 13 STANDARD Grade n/a Notify the CRS that RIA-1113 High Alarm Setpoint is 8.6 x 10 3 (8600) CPM.

CRS notified of RIA-1113 setpoint raised to 8.6 x 10 3 (8600) CPM.

S U Comment:

NOTE: Evaluator Cue: If Operator asks if Batch Card needs to be signed in "Alarm Set By:" space, RESOND: YES, sign the Batch Card END OF TASK

JPM: RO SYSTEM h CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER TO UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

  • Waste Gas Discharge Monitor, RIA-1113 Batch Card background reading = 95 CPM.
  • Waste Gas Discharge Monitor, RIA-1113 Batch Card Release Limit = 8500 CPM
  • Waste Gas Discharge Monitor, RIA-1113 Batch Card "High Alarm Setpoint" = 8600 CPM.
  • Release Order, Form HP 6.6-3 (batch card) is available.
  • Breaker 34 on Y-01 is closed.
  • RIA-1113 has been verified aligned for service per Attachment 5, Checklist 38, "Gaseous Process Radiation Monitors System Checklist"
  • A check source has been completed on RIA-1113 with a reading of 620000CPM.

INITIATING CUES:

  • The CRS directs you to set up Waste Gas Discharge Monitor, RIA-1113 High Alarm Setpoint using SOP-38 Section 7.3.6 to a setpoint of 8600 cpm.

PALISADES NUCLEAR PLANT Page 8 of 10 JULY 2008 JPM: RO SYSTEM h SIMULATOR OPERATOR INSTRUCTIONS Initial Setup: Any IC RIA-1113 initial High al arm setpoint 2.5 x 10 3 Fill out WGDT Release Authorization, for HP 6.6-3 (procedure HP-6.6, Attachment

4) as follows:

HP 6.6-3, page 1 of 2: SEE ATTACHED HP FORM RIA-1113 initial High al arm setpoint 2.5 x 10 3 RESET RIA-1113 to 2.5 x 10 3 at end of JPM PALISADES NUCLEAR PLANT Page 9 of 10 JULY 2008 PALISADES NUCLEAR PLANT Page 10 of 10 JULY 2008 FORM HP 6.6-3 Proc No HP 6.6 Attachment 3 WGDT RELEASE AUTHORIZATION Revision 21 Page 1 of 2 WGDT # __T-101C______ Batch Number __

08________013_____ Isolation Date 07/12/07 Time 1200

Release Volume 32.5 m 3 Isolation Pressure 93 psig

Gamma Conc 7.24E-5 Ci/cc Release Pressure 93 psig

Expected RIA-1113 RDG 9.5 x 10 1 cpm Qtr A i/C i 0.1 (must be < 0.5)

Year-to-Date A i/C i 0.24 (must be < 1.0)

APPROVAL TO RELEASE RIA-1113 Release Limit 8.5E+3 cpm RETS Analyst Jane Retssup Today / 0815 Shift Manager Ralph Manager Today / 0840 Main Exhaust Fan In Service V-6A V-6B I/S fan Purge RIA-1113 Source Check RIA-1113 6.5 X 10 5 cpm

RIA-1113 Release Limit 8.5 x 10 3 cpm

RIA-1113 Background

+ 9.5 x 10 1 cpm RIA-1113 Alarm Setpt = 8.6 x 10 3 cpm Alarm Set By:

Alarm Verified By:

Purge RIA-1113 After Release Reset Alarm to 2500 cpm

Alarm Reset By:

C O N T R O L R M O P E R Alarm Reset Verified By:

If RIA-1113 is not operational, effluent releases may continue provided that prior to release:

1. At least two independent samples are analyzed; and
2. At least two technically qualified members of the Facility Staff independently verify the release rate calculations and discharge line valving.

Palisades ODCM Appendix A, Table A-1, Item 1.a Action 1.

Remarks: