Fermi 2, Enclosure 13 to
NRC-13-0004
, Calculation DC-6443, Vol I,
DCD
1, Rev. a, Reactor Core Thermal Power Uncertainty with
Feedwater
Flow Measured by
LEFM
Checkplus C System.
ML13043A657
Person / Time
Site:
Fermi
Issue date:
01/03/2013
From:
Ugorcak P A
DTE Electric Company
To:
NRC/RGN-III
Shared Package
ML130440186
List:
ML13043A655
ML13043A657
ML13043A658
NRC-13-0004, Fermi 2, Enclosure 13 to NRC-13-0004, Calculation DC-6443, Vol I, DCD 1, Rev. a, Reactor Core Thermal Power Uncertainty with Feedwater Flow Measured by LEFM Checkplus C System.
NRC-13-0004, Fermi 2, Enclosure 14 to NRC-13-0004, Calculation DC-4608, Vol 1, DCD 1, Rev. 0, Numac Power Range Neutron Monitoring System (Prnm) Surveillance Validation.
NRC-13-0004, Fermi 2, Enclosure 9 to NRC-13-0004, NEDO-33578, Rev. 0, Safety Analysis Report for Fermi Generating Station Unit 2 Thermal Power Optimization.
NRC-13-0004, License Amendment Request for Measurement Uncertainty Recapture (MUR) Power Uprate
References
NRC-13-0004
DC-6334, Vol I
DCD
1, Rev A
Download:
ML13043A657
(51)
v
•
d
•
e
v
t
e
Similar Documents at
Fermi
Category:Calculation
[Table view]
Text
Category
:
Calculation
Navigation menu
Personal tools
Create account
Log in
Namespaces
Page
Discussion
English
Views
Read
View source
View history
More
Search
Navigation
Main page
Recent changes
Random page
Community
Help
Patreon
Databases
ENS
LER
Findings
Inspections
TSTF
Tools
What links here
Related changes
Special pages
Printable version
Permanent link
Page information
Browse properties