Finding | |
|---|---|
| Title | Technical Specification Inoperability of MSIVs Due to Failure to Conduct Diagnostic Testing |
| Description | The inspectors identified a non-cited violation of Technical Specification (TS) 3.7.1.5, Main Steam Line Isolation Valves, due to one or more MSIVs being inoperable for a time greater than the allowed outage time and a plant shutdown was not completed in accordance with the action statement of TS 3.7.1.5. MSIV diagnostic testing in accordance with EGR-NGGC-0205, Air Operated Valve (AOV) Reliability Program, had not been conducted by the licensee. This contributed to the licensee not identifying long-term corrosion/oxidation of the valve piston rings that resulted in the B and C MSIV failure to initially close during stroke time testing on April 21, 2012. The licensee conducted repairs of all three MSIVs and restored them to an operable condition prior to entering Mode 4 following the completion of an ongoing refueling outage. The licensee entered this condition into their corrective action program (CAP) as Nuclear Condition Report (NCR) 531773. The failure to properly classify the MSIVs as risk significant and implement MSIV diagnostic testing in accordance with the AOV program procedure EGR-NGGC-0205 was a performance deficiency (PD). The PD is more than minor because it is associated with the equipment performance attribute of the Mitigating Systems cornerstone and affected the cornerstone objectives of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The finding is also associated with the containment isolation barrier performance attribute of the Barrier Integrity cornerstone and affected the cornerstone objective of providing reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events. Specifically, the failure to conduct periodic diagnostic testing that would have identified long-term internal valve degradation due to unexpected corrosion/oxidation of the valve piston rings in all three MSIVs resulted in two MSIVs failing to initially close during TS stroke time testing on April 21, 2012, and excessive internal friction in all three MSIVs such that they may not have been capable of performing their safety-related closure function during certain design basis events. Using IMC 0609, Appendix A, The Significance Determination Process for Findings At- Power, the inspectors determined there was an actual loss of safety function greater than the TS allowed outage time associated with the finding which required a more detailed risk evaluation. A detailed risk evaluation was performed by a regional senior reactor analyst. The result of the analysis of the risk of the PD was a delta core damage frequency (CDF) of <1E-6/year and a delta Large Early Release Fraction (LERF) of <1E- 7/year, a GREEN finding. No cross-cutting aspect was assigned to this finding because licensee decisions made in regard to classifying the MSIVs in the AOV program were made more than three years ago and therefore, not reflective of current plant performance. |
| Site: | Harris |
|---|---|
| Report | IR 05000400/2012009 Section 4OA5 |
| Date counted | Dec 31, 2012 (2012Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | G Macdonald J Zeiler R Musser |
| INPO aspect | |
| ' | |