- 05000213/LER-1986-010, :on 860226,unauthorized Maint Electrician Found Exiting Locked High Radiation Area.Caused by Failure of Mgt Personnel to Provide Adequate Instruction to Workers on Use & Control of High Radiation Key (← links)
- ML20155H155 (← links)
- 05000348/LER-1988-010, :on 880411,determined That Individually Neither of Control Room Pressurization Units Able to Maintain Required Pressure of at Least 0.125 Inches Water Gauge. Caused by Open Penetrations (← links)
- 05000331/LER-1986-004, :on 860212,RWCU Sys Isolated Due to High Differential Temp Indication.Caused by Minor Degradation of Manual Valves on Vent & Drain Lines of Regenerative HX A. Valves Tightened (← links)
- ML20113E730 (← links)
- ML20090L763 (← links)
- 05000220/LER-1983-028-03, /03L-0:on 831027,oil Reservoir Indicators to Snubbers 39-HS-18 & 19 Found Off Scale on Low End.Snubbers Removed,Replaced,Tested & Found Operable.No Cause Noted.No Corrective Action Necessary (← links)
- 05000265/LER-1983-022-01, /01T-0:on 831115,during Routine Insp,Msiv Room Interlock Doors Found Defeated,While MSIV Room Part of Secondary Containment,Resulting in Degradation of Secondary Containment Integrity (← links)
- 05000336/LER-1982-033-03, /03L-0:on 820722,while Testing Steam Driven Auxiliary Feedwater Pump,Turbine Failed to Reach Min Rpm. Caused by Insufficient Steam Supply.Steam Valve Collar Adjusted (← links)
- 05000155/LER-1982-020-03, /03L-0:on 820622,reactor Depressurizing Sys Isolation Valves on Two of Four Loops Not Returned to Operable Status.Caused by Slide Links Inadvertently Left Open,Due to Operator Error (← links)
- 05000309/LER-1981-022-03, /03L-0:on 810925,quarterly Surveillance Measurement of HPSI Valve Steam Stops Was in Progress When HPSI Valve Found to Have Adverse Tolerance Buildup.Caused by Periodic Disassembly & Normal Wear.Valve Readjusted (← links)
- 05000333/LER-1981-079-03, /03L-0:on 811116,sample of Standby Gas Treatment Charcoal Was Less than 99% Efficient in Removing Methyl Iodide.Apparently Caused by Age of Charcoal.Charcoal Replaced (← links)
- ML20034H495 (← links)
- ML20032D845 (← links)
- 05000333/LER-1981-072-03, /03L-0:on 811006,HPCI Turbine Exhaust Diaphragm Pressure Switch 23-PS-86B Found Set Higher than Tech Spec. Caused by Instrument Drift.Instrument Calibr & Surveillance Increased (← links)
- 05000333/LER-1981-068-03, /03L-0:on 810824,while Conducting Surveillance to Satisfy Tech Spec Table 4.2-2,HPCI High Steam Flow Differential Pressure Switch Was Found Set Above Tech Specs. Caused by Instrument Drift.Instrument Recalibr (← links)
- ML20027A438 (← links)
- 05000370/LER-1983-019-01, /01T-0:on 830526,containment Pressure Control Sys Monthly Test Failed to Satisfy Surveillance Requirements to Check Permissive/Termination Setpoint Accuracy.Caused by out-of-tolerance Instruments.Modules Recalibr (← links)
- ML20024B234 (← links)
- ML20024B232 (← links)
- 05000334/LER-1981-049-03, /03L-0:on 810508,main Steam Trip Valve TV-MS-101B Would Not Stroke in Required Time Envelope on Steam Line Isolation.Caused by Solenoid Orifices Being Coated W/Dust & Residue,Restricting Air Flow When Venting Air Pistons (← links)
- ML19347E668 (← links)
- 05000366/LER-1980-112-03, /03L-0:on 800723,during Steady State Operation, While Performing on HPCI Steam Line Delta P Flow Switch 2E41-N004,high Side micro-switch Found Inoperative.Caused by micro-switch Subcomponent Failure (← links)
- 05000336/LER-1981-007-03, /03L-0:on 810127,diesel Generator 12U Oil Cooler Found Leaking Svc Water.Caused by Corroded Sacrificial Zinc Anode.Zinc Inspected & Replaced & Maint Insp of Zincs Increased from Monthly to Weekly (← links)
- 05000364/LER-1989-013, :on 891019,reactor Tripped Due to lo-lo Level in Steam Generator 2C.Caused by Operator Incorrectly Transferring Steam Generator Level Control to Main Feedwater.Involved Personnel Counseled (← links)
- 05000309/LER-1980-009-03, /03L-0:on 800408,during Routine Monthly Surveillance Procedure 3.1.2,LPIS Loop 3 Header Stop Valve Failed to Operate as Required.Caused Unstated.Valve Recycled & Operated Satisfactorily (← links)
- ML19256B794 (← links)
- ML19249E105 (← links)
- ML19242A524 (← links)
- ML18046B214 (← links)
- L-05-125, Eleventh Refueling Outage Inservice Inspection Report (← links)
- ML051950501 (← links)
- ML030300756 (← links)