ML19317D544

From kanterella
Revision as of 07:37, 1 February 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Forwards Rept Documenting Successful Completion of Reactor Bldg Integrated Leak Rate Test.W/O Encl
ML19317D544
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 06/22/1976
From: Parker W
DUKE POWER CO.
To: Moseley N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 7912060794
Download: ML19317D544 (1)


Text

-- ,

.. n DuxE POWER COMPANY Powtu BetwlNO a 422 SoCTH CHcECH STREET, CIMH14TTE. N. C. 282 u w e w Au o. Pa n a t a, .J m.

Regulatory 0 De'

v. n Pac s.cc=v Tc.re o=c Aa ta 704

!, e g a ns Pao 3wC'io= 3'3-4093 June 22, 1976 g #t te s' @

Mr. Norman C. Moseley, Directo p l g =, .

,p U. S. Nuclear Regulatory Co.., .

a g g Suite 818 V '

230 Peachtree Street, Nor Atlanta, Georgia 30303 g st T[ g d5 JU/GOIO76A A.s. h % g I

S gy -

Re: Oconee Unit 1 4 #

4 b Docket No. 50-269 ;f,,C, ig bl>> S

Dear Mr. Moseley:

"t. 2 ,

s w,;, i,ac-Pursuant to the Oconee Nuclear Station Technical Specification 4.4.1.1.7, please find attached a report documenting the successful completion of the Oconee Unit 1 Reactor Building Integrated Leak Rate Test.

Ver truly yours, Nec,l U . n h'

~' William O. Parker, J MST:vr Attachment cc: Mr. B. C. Rusche (40)

OdOU 7912060 K y