_ - . . . . _ . . _ _ _-. .. _ . _ _ ..

~

1 FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3 l DOCKET NO. 50-302/ LICENSE NO. DPR-72 l

l l

i ATTACHMENT LICENSE AMENDMENT REQUEST #221, REVISION 2 ONCE THROUGH STEAM GENERATOR TUBE SURVEILLANCE PROGRAM i

i Proposed Technical Specification Change Page l

l 9811240067 981117 DR ADOCK 050003 2 i

I

- . . . ~ . .- . . - . . . . . - . - . _ - . - - - . - . . ~ . - . . - - . . ~ . - .-- =-.. . - .-

Reporting Requirements

'.' 5.7 5.7 Reporting Requirements 5.7.2 Special Reports (continued)

5. .For first span "B" 0TSG pit-like IGA, a summary of analyses performed to determine if estimated leakage based on the projected end-of-cycle perce9t throughwall distribution-exceeds the leak limit (dete'rmined from the licensing basis dose calculation for the main steamline break) for the next operating cycle.
6. A deterministic assessment for the first span "B" 0TSG pit-like IGA.

Results of 0TSG tube inspections that fall into Category C-3 ,

shall be reported to the NRC prior to resumption of plant 'l operation. This report shall provide a description of '

investigations conducted to determine cause of the tube l degradation and corrective measures taken to prevent recurrence.

I II I I I

l l

l L

i' i

4 Crystal River Unit 3 5.0-29A Amendment No.

. .. . . - -- - . .- ---------.-- -,