Meeting Slides - Preapplication with Constellation on Planned Fleet Alternative Request to Adopt OMN-2
ML24100A767
Person / Time
Site: Calvert Cliffs, Dresden, Peach Bottom, Nine Mile Point, Byron, Braidwood, Limerick, Ginna, Clinton, Quad Cities, FitzPatrick, LaSalle  Constellation icon.png
Issue date: 04/11/2024
From: Robert Kuntz
Constellation Energy Generation
To: Rhoades D
Plant Licensing Branch III
Wall, SP
References
Download: ML24100A767 (1)


Text

  • The relief request is for an alternative pursuant to 10 CFR 50.55a (z), Alternatives to codes and standards requirements, to utilize ASME Code Case OMN-32, Alternative Requirements for Range and Accuracy of Pressure, Flow, and Differential Pressure Instruments Used in Pump T ests.
  • Code Case OMN-32 provides alternative testing instrument accuracy and range requirements for flow, pressure, and differential pressure instruments used for Group A, Group B, Comprehensive, and Preservice pump tests

-Instruments used for speed and vibration testing would continue to meet the existing instrument accuracy and range requirements in ASME OM Code.

  • Code Case OMN-32 would apply to all pumps in the Inservice T esting (IST)

Program at each of Constellations 21 Nuclear Units.

or al

es ams Gener ement f ogr al al

T pr Gener Gener Code ode Cas ds requir OM OM C tandar ASME ASME s for updating IS on esting s

ement ervice t Conditions on Conditions Ins Requir

s

ating plant

oper

  • Constellation is targeting submittal by the end of April 2024 with a standard one-year approval period.
  • Constellations submittal will incorporate two comments provided by the NRC during the review and subsequent approval of Code Case OMN-32.

-The title of the proposed Requirements and the corresponding T able were modified to state, Required Instrument Accuracy and Range.

-The use of analytical methods may be used provided the parameter determination meets the required OMN-32 accuracy.