ML24031A660
| ML24031A660 | |
| Person / Time | |
|---|---|
| Site: | HI-STORM 100 |
| Issue date: | 01/31/2024 |
| From: | Manzione K Holtec |
| To: | Kristina Banovac Office of Nuclear Material Safety and Safeguards, Document Control Desk |
| Shared Package | |
| ML24031A659 | List: |
| References | |
| 5021074 | |
| Download: ML24031A660 (1) | |
Text
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797- 0900 Fax (856) 797- 0909
January 31, 2024
Ms. Kristina Banovac, Project Manager Division of Spent Fuel Office of Nuclear Material Safety and Safeguards
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Docket No. 72-1040 Certificate of Complia nce (CoC) No. 1040
Subject:
Submittal of RSI Responses for Revision to HI-STORM UMAX CoC Amendments 0, 1, and 2
Reference [1] Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM UMAX Canister Storage System -
Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0070, from K. Banovac (NRC) to K. Manzione (Holtec), dated 12/18/23
Dear Ms. Banovac:
Holtec is pleased to submit the attached responses to the staffs RSI on the revisions HI-STORM UMAX CoC Amendments 0, 1, 2. The attachments contain the responses and marked up proposed revisions to the FSAR s associated with each CoC.
If you have any questions, pleasecontact me at (856)-797-0900 ext. 3951.
Sincerely,
Kimberly Manzione Director of Licensing - NMSS Projects Holtec International
Attachments : Responses to RSIs for Revision 1 to Amendments 0, 1, and 2 : HI -STORM UMAX FSAR Proposed FSAR Revision 2.1A : HI -STORM UMAX FSAR Proposed FSAR Revision 3.1A : HI -STORM UMAX FSAR Proposed FSAR Revision 4.1A
Document ID: 5021074 Page 1 of 1