ML19025A267
| ML19025A267 | |
| Person / Time | |
|---|---|
| Site: | SHINE Medical Technologies |
| Issue date: | 01/22/2019 |
| From: | Olvera J SHINE Medical Technologies |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| 2019-SMT-0006 | |
| Download: ML19025A267 (12) | |
Text
ENCLOSURE 6 SHINE MEDICAL TECHNOLOGIES, INC.
MEETING SLIDES FOR THE JANUARY 29 AND 30, 2019 MEETING BETWEEN SHINE MEDICAL TECHNOLOGIES, INC. AND THE NRC SHINE IDENTIFICATION OF SAFETY-RELATED CONTROLS PUBLIC VERSION 11 pages follow
Identification of Safety-Related Controls John Olver~, Safety Analysis Manager Health. llluminatedT:
Summary
- Methodology for Integrated Safety Analysis
- Current status of Integrated Safety Analysis
- Example Process Hazard Analysis Accident Sequences
- Discussion of preliminary list of safety-related controls
- Review of detailed tables of safety-related controls SHINE Medical Technologies I2
Methodology for the Integrated Safety Analysis
- The Integrated Safety Analysis (ISA) is prepared in accordance with the requirements of Subpart Hof 10 CFR Part 70
- Guidance documents SHINE used in the preparation of the ISA include:
- NUREG-1513, "Integrated Safety Analysis Guidance Document"
- NUREG-1520, "Standard Review Plan for Fuel Cycle Facilities License Applications"
- Final Interim Staff Guidance Augmenting NUREG-1537
- NUREG/CR-6410, "Nuclear Fuel Cycle Facility Accident Analysis Handbook" SHINE Medical Technologies I 3
Methodology for the Integrated Safety Analysis
- Process Hazard Analyses (PHA) accident sequence development:
- Based on hazard evaluation results and the guidance provided in the Interim Staff Guidance Augmenting NUREG-1537
- Estimate an uncontrolled risk index for each potential accident sequence (likelihood x unmitigated consequences)
- Identified engineered and administrative controls for those scenarios which have an unacceptable risk
- Evaluate controlled risk indices crediting risk reduction from controls
- Develop list of safety-related controls SHINE Medical Technologies I4
Methodology for the Integrated Safety Analysis
- Types of Controls - Safety-related
- Active Engineered Controls (AEC)
- Passive Engineered Controls (PEC)
- Administrative Controls (ADM)
- Types of Controls - Nonsafety-Related
- Defense-in-Depth (DID)
SHINE Medical Technologies I 5
Current Status of the Integrated Safety Analysis
- Hazard identification and evaluations completed
- Process Hazard Analysis completed
- Safety-related controls drafted and in review
- Integrated Safety Analysis Summary Report drafted and in review
- sHINE Medical Technologies I6
Security-Related Information - Withheld Under 10 CFR § 2.390 Example Process Hazard Analysis Accident Sequences
- Inadvertent Reactivity Insertion or Criticality Security-Related Information SHINE Medical Technologies I 7
Security-Related Information - Withheld Under 10 CFR § 2.390 Example Process Hazard Analysis Accident Sequences
- Deflagration and Detonation Security-Related Information SHINE Medical Technologies I 8
Security-Related Information - Withheld Under 10 CFR § 2.390
-~
Example Process Hazard Analysis Accident Sequences
- Reduction in Cooling Security-Related Information SHINE Medical Technologies I 9
Security-Related Information - Withheld Under 10 CFR § 2.390 Discussion of Draft Safety-Related Controls Security-Related Information SHINE Medical Technologies j10
Security-Related Information - Withheld Under 10 CFR § 2.390 Discussion of Draft Safety-Related Controls Security-Related Information SHINE Medical Technologies j11