ML13066A331
| ML13066A331 | |
| Person / Time | |
|---|---|
| Site: | Kewaunee |
| Issue date: | 03/07/2013 |
| From: | Dominion Energy Kewaunee |
| To: | NRC/RGN-III/DRMA |
| References | |
| EA-12-272 | |
| Download: ML13066A331 (20) | |
Text
Kewaunee Power Station NRC Region III Regulatory Conference Loss of PPCS Indication For SPING RMs
© 2007 Dominion
Agenda g
- Opening p g remarks
- Event description
- Regulatory R l t significance i ifi
- Conclusion
- Closing remarks 2 © 2007 Dominion
Opening p g Remarks Dominion is committed to preserving the health and safety f t off the th public bli 3 © 2007 Dominion
Opening p g Remarks
- Preliminaryy Violation
- Kewaunee Power Stations unidentified loss of SPING indication on the PPCS and RADSERV stations precluded action to restore the capability p y to classify y EALs RG1.1 and RS1.1
- Agree performance deficiency existed
- Differ with significance of finding 4 © 2007 Dominion
Event Description p
- Hardware failure
- RADSERV
- Interface between SPING units and PPCS
- Additional Data Acquisition Modules lost
- Local SPING indication remained available
- Upon discovery of RADSERV failure, restoration completed same day 5 © 2007 Dominion
Regulatory g y Significance g
RADSERV failure- Hardware issue P i Previous hardware h d failures f il have h been b
evaluated under 10 CR 50.47(b)(8) 50 47(b)(8) 6 © 2007 Dominion
Regulatory g y Significance g
5.8 10 CFR 50.47(b)(8), Emergency Facilities and Equipment PLANNING STANDARD:
- Adequate emergency facilities and equipment to support the emergency response are provided and maintained.
PS FUNCTIONS: 1. Adequate facilities are maintained to support emergency response.
- 2. Adequate equipment is maintained to support emergency response.
7
Regulatory g y Significance g
- H. Emergency Facilities and Equipment
- 5.b. radiological monitors, (e.g., process, area, emergency, effluent, wound and portable monitors and sampling equipment);
8 © 2007 Dominion
Regulatory g y Significance g
( )( )
- White threshold
- Equipment necessary to implement the E-plan is not available or not functional
- Period of longer than 7 days from time of discovery y
- Without Compensatory Measures 9 © 2007 Dominion
Regulatory g y Significance g
( )( )
- Green threshold
- A significant amount of equipment necessary to implement the E-plan is not available or functional to the extent that any key ERO member could not p perform his/her assigned g
functions, in the absence of compensatory measures.
10 © 2007 Dominion
Regulatory g y Significance g
IMC 0609 Basis Not all hardware Assessed by scope of failures under control outage from of licensee y discovery
- RADSERV failure
- Restored same day
- Hardware failure of discovery 11 © 2007 Dominion
Regulatory g y Significance g
- Industryy OE
- Columbia Generating Station (05000397/2012502)
Fi di Finding St d d Standard Si ifi Significance Effluent Monitor Classification 10 CFR 50.47(b)(4) White Thresholds Inaccurate methods for assessing the 10 CFR 50.47(b)(9) White offsite consequences of a radiological release were inaccurate Reactor Building High Range 10 CFR 50.47(b)(8) Green - Licensee Identified Exhaust monitor was unavailable 38 of 149 months and corrective actions were ineffective in restoring the availability and reliability of the monitor 12 © 2007 Dominion
Regulatory g y Significance g
- Columbia Green Findingg
- Failed to provide and maintain RX Building High Range Exhaust RM
- Unavailable 38 out of 149 months
- Planning Standard determined to be degraded
- Causing C i potential t ti l delays d l
- Classification and radiological assessments 13 © 2007 Dominion
Regulatory g y Significance g
- Columbia White Findingg
- Finding
- Failure to maintain a standard EAL scheme
- Inappropriately calculated and changed RM thresholds for Site Area Emergency and General Emergency 14 © 2007 Dominion
Additional Information
- Actual duration of vulnerabilityy
- Fast breaking LOCA
- RCS > 350 350°F F on 3/24/11 at 0300
- Six days
- Classification Methodology
- Shift Manager perspective 15 © 2007 Dominion
Additional Information
- EAL scheme diversification
- NEI 99-01 Rev. 4
- Fission product barrier challenges
- Effluent ICs do not stand alone
- EOPs and CSF reduce ambiguity and time
- NRC Regulatory Analysis of NEI 99-01
- Plant conditions more timely than radiological measurements 16 © 2007 Dominion
Root Cause Evaluation RC-1 Absence of a programmatic requirement to pe periodically od ca y monitor o to RADSERV S V aand d PPCS RC 2 RC-2 System platform is obsolete and difficult to maintain 17 © 2007 Dominion
Conclusions
- RADSERV failure was a hardware issue
- Restored same day as discovery
- 10 CFR 50.47 50 47 (b)(8) Green Finding
- Precedence of the Columbia finding 18 © 2007 Dominion
Closing g Remarks
- Dominion Acknowledges g
- Degraded planning standard
- Importance of equipment associated with EP
- Violation has occurred
- Corrective actions 19 © 2007 Dominion
Closing g Remarks Dominion is committed to preserving the health and safety of the public 20 © 2007 Dominion