- 05000259/LER-1987-006, :on 870302,discovered That Routine Flow Rate Surveillance on Control Room Emergency Ventilation Train B Performed Incorrectly Night Before.Caused by Personnel Error.Flow Measured & Correctly Set (← links)
- 05000259/LER-1987-014-01, :on 870708,control Room Emergency Ventilation Sys Measured Flow Rates in Excess of Design Basis Flow Rate. Caused by Throttle Dampers Not Set to Deliver Flow on Optimum Filtration.Procedure to Be Revised (← links)
- ML20151K747 (← links)
- 05000259/LER-1987-014, :on 870708,engineers Measured Flow Rates in Excess of Design Basis Flow Rate.Throttle Dampers on Two Control Room Emergency Ventilation Units Unset Since Sys Installation.Procedures Revised (← links)
- ML20126D833 (← links)
- 05000277/LER-1992-016-01, :on 920911,discovered That Containment Venting & Outgoing Activities Had Been Started While SBGTS Awas Removed from Svc & Inoperable.Caused by Personnel Error. Containment de-inerting Terminated (← links)
- ML20076K800 (← links)
- 05000280/LER-1982-086-03, /03L-0:on 820827,radiation Monitor RM-LW-10F Indicated 9.0E4 CPM W/O Annunciation of Alarm.Caused by Defective Push Button & Setpoint Drift.Push Button Replaced & Monitor Recalibr (← links)
- 05000280/LER-1982-075-03, /03L-0:on 820626,setpoint for CC Rad Monitor RM-CC-105 Discovered Greater than Twice Background.Caused by Decreasing Activity in Computer Cooling Sys.Setpoint Readjusted W/New Background Activity Levels (← links)
- 05000331/LER-1982-012-03, /03L-0:on 820208,during Surveillance Testing,Msiv Leakage Control Sys Bypass Valve MOV-8403C Failed to Close. Caused by Failed Auxiliary Switch on Motor Starter Contractor Coil Mfg by Allis Chalmers.Switch Replaced (← links)
- ML20041A517 (← links)
- ML20036B513 (← links)
- 05000331/LER-1981-037-01, /01T-0:on 811017,during Valve Lineup Check,Main Steam Line Leakage Control Sys D Manual Valve V-84-16 Was Found Closed.Caused by Valving Error Due to Poor Lighting & Accessibility & Lack of Valve Labels.Lineup Performed (← links)
- 05000280/LER-1981-042-03, /03L-0:on 810902,high Alarm Setpoint for Component Cooling Radiation Monitor RM-CC-105 Was Exceeded W/O Surge Tank Vent Closing or Annunciator Alarming.Caused by Failed Log Ratemeter Card.Card Replaced & Instrument Recalibr (← links)
- 05000280/LER-1981-062-03, /03L-0:on 811017,radiation Monitor RI-CC-105 Failed to Give Indication.Caused by Broken Wire Located on Detector Probe.Wire Reconnected (← links)
- 05000298/LER-1979-013-03, /03L-0 on 790508:correct Drywell to Suppression Chamber Reading Not Established.Caused by Leaking Inlet Purge Valve.Valve Repaired & Leak Tested (← links)
- 05000298/LER-1979-013, Forwards LER 79-013/03L-0 (← links)
- ML18152A331 (← links)
- ML18152A026 (← links)
- 05000281/LER-1980-008, Forwards LER 80-008/03L-0 (← links)
- IR 05000280/1979046 (← links)
- 05000280/LER-1979-015-03, /03L-0 on 790422:liquid Waste Disposal Radiation Monitor Failed to Give High Alarm & Trip Release Valve. Caused by Procedural Inadequacy.Procedures Modified (← links)
- ML18036B238 (← links)
- ML18036A768 (← links)
- IR 05000259/1989019 (← links)
- 05000259/LER-1987-006-01, :on 870302,discovered That Routine Flow Rate Surveillance on Control Room Emergency Ventilation Train B Performed Incorrectly on 870301.Caused by Personnel Error. Correct Zeroing Procedure Clarified (← links)
- IR 05000259/1978022 (← links)
- ML17180B105 (← links)