{{#Wiki_filter:March 26, 2018 Technical Specifications Task Force 11921 Rockville Pike, Suite 100 Rockville, MD 20852 | {{#Wiki_filter:March 26, 2018 | ||
Technical Specifications Task Force 11921 Rockville Pike, Suite 100 | |||
Rockville, MD 20852 | |||
==SUBJECT:== | ==SUBJECT:== | ||
ACCEPTANCE FOR REVIEW REGARDING TRAVELER TSTF-566, "REVISE ACTIONS FOR INOPERABLE RHR SHUTDOWN COOLING SUBSYSTEMS" (EPID L-2018-PMP-0001) | ACCEPTANCE FOR REVIEW REGARDING TRAVELER TSTF-566, "REVISE ACTIONS FOR INOPERABLE RHR SHUTDOWN COOLING SUBSYSTEMS" (EPID L-2018-PMP-0001) | ||
==Dear Members of the Technical Specifications Task Force:== | ==Dear Members of the Technical Specifications Task Force:== | ||
By letter dated January 19, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18019B187), you | By letter dated January 19, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18019B187), you subm itted to the U.S. Nuclear Regulatory Commission (NRC) a request to incorporate Traveler TSTF-566, "Revise Actions for Inoperable RHR Shutdown Cooling Subsystems," into the standard technical specifications. | ||
Section 170.21 of Title 10 of the Code of Federal Regulations requires that Travelers are subject to fees based on the full cost of the review. You did not request a fee waiver; therefore, NRC staff hours have been billed accordingly. The NRC | |||
MILESTONE SCHEDULE DATE Issue Request for Additional Information May 4, 2018 Issue Draft Safety Evaluation October 16, 2018 Issue Final Safety Evaluation January 18, 2019 | Section 170.21 of Title 10 of the Code of Federal Regulations requires that Travelers are subject to fees based on the full cost of the review. You did not request a fee waiver; therefore, NRC staff hours have been billed accordingly. The NRC st aff estimates that the review will require approximately 420 staff hours including project management time. | ||
The NRC staff has completed a preliminary review of your submission and determined it is sufficiently complete and appropriate to initiate a more comprehensive review. The review will generally follow the schedule below. | |||
MILESTONE SCHEDULE DATE Issue Request for Additional Information May 4, 2018 Issue Draft Safety Evaluation October 16, 2018 Issue Final Safety Evaluation January 18, 2019 The dates are provided for draft and final safety evaluations (SEs) have been expedited at your request. In order to meet these dates the TSTF will need to respond to RAIs in 30 days and | |||
provide comments to the draft SE in 15 days. If you have any questions, please contact me at (301) 415-1774 or via e-mail to Michelle.Honcharik@nrc.gov | |||
. Sincerely, | |||
R/A Michelle C. Honcharik, Senior Project Manager Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation | |||
Project No. 753 | |||
ML18057A162; *concurred via e-mail NRR-106 OFFICE DSS/STSB DSS/STSB* NAME MHoncharik VCusumano DATE 3/22/2018 3/26/2018 Technical Specifications Task Force Project No. 753 cc: Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100 | |||
Rockville, MD 20852 Attention: Brian D. Mann E-mail: brian.mann@excelservices.com | |||
James P. Miksa Entergy Nuclear Operations, Inc. | |||
Palisades Nuclear Power Plant 27780 Blue Star Memorial Highway Covert, MI 49043 | |||
Email: jmiksa@entergy.com | |||
Jordan L. Vaughan Duke Energy EC2ZF / P.O. Box 1006 | |||
Charlotte, NC 28202 | |||
Email: jordan.vaughan@duke-energy.com | |||
Lisa L. Williams Energy Northwest Columbia Generating Station PO Box 968 | |||
Mail Drop PE20 Richland, WA 99352-0968 E-mail: llwilliams@energy-northwest.com | |||
David M. Gullott Exelon Generation | |||
4300 Winfield Road | |||
Warrenville IL 60555 Email: David.Gullott@exeloncorp.com | |||
Wesley Sparkman | |||
Southern Nuclear Operating Company | |||
42 Inverness Center Parkway / Bin B237 Birmingham, AL 35242 Email: wasparkm@southernco.com}} | |||
Revision as of 01:35, 29 June 2018
| ML18057A162 | |
| Person / Time | |
|---|---|
| Site: | Technical Specifications Task Force |
| Issue date: | 03/26/2018 |
| From: | Honcharik M C NRC/NRR/DSS/STSB |
| To: | Technical Specifications Task Force |
| Honcharik M C | |
| References | |
| EPID L-2018-PMP-0001 | |
| Download: ML18057A162 (3) | |
Text
March 26, 2018
Technical Specifications Task Force 11921 Rockville Pike, Suite 100
Rockville, MD 20852
SUBJECT:
ACCEPTANCE FOR REVIEW REGARDING TRAVELER TSTF-566, "REVISE ACTIONS FOR INOPERABLE RHR SHUTDOWN COOLING SUBSYSTEMS" (EPID L-2018-PMP-0001)
Dear Members of the Technical Specifications Task Force:
By letter dated January 19, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18019B187), you subm itted to the U.S. Nuclear Regulatory Commission (NRC) a request to incorporate Traveler TSTF-566, "Revise Actions for Inoperable RHR Shutdown Cooling Subsystems," into the standard technical specifications.
Section 170.21 of Title 10 of the Code of Federal Regulations requires that Travelers are subject to fees based on the full cost of the review. You did not request a fee waiver; therefore, NRC staff hours have been billed accordingly. The NRC st aff estimates that the review will require approximately 420 staff hours including project management time.
The NRC staff has completed a preliminary review of your submission and determined it is sufficiently complete and appropriate to initiate a more comprehensive review. The review will generally follow the schedule below.
MILESTONE SCHEDULE DATE Issue Request for Additional Information May 4, 2018 Issue Draft Safety Evaluation October 16, 2018 Issue Final Safety Evaluation January 18, 2019 The dates are provided for draft and final safety evaluations (SEs) have been expedited at your request. In order to meet these dates the TSTF will need to respond to RAIs in 30 days and
provide comments to the draft SE in 15 days. If you have any questions, please contact me at (301) 415-1774 or via e-mail to Michelle.Honcharik@nrc.gov
. Sincerely,
R/A Michelle C. Honcharik, Senior Project Manager Technical Specifications Branch Division of Safety Systems Office of Nuclear Reactor Regulation
Project No. 753
ML18057A162; *concurred via e-mail NRR-106 OFFICE DSS/STSB DSS/STSB* NAME MHoncharik VCusumano DATE 3/22/2018 3/26/2018 Technical Specifications Task Force Project No. 753 cc: Technical Specifications Task Force c/o EXCEL Services Corporation 11921 Rockville Pike, Suite 100
Rockville, MD 20852 Attention: Brian D. Mann E-mail: brian.mann@excelservices.com
James P. Miksa Entergy Nuclear Operations, Inc.
Palisades Nuclear Power Plant 27780 Blue Star Memorial Highway Covert, MI 49043
Email: jmiksa@entergy.com
Jordan L. Vaughan Duke Energy EC2ZF / P.O. Box 1006
Charlotte, NC 28202
Email: jordan.vaughan@duke-energy.com
Lisa L. Williams Energy Northwest Columbia Generating Station PO Box 968
Mail Drop PE20 Richland, WA 99352-0968 E-mail: llwilliams@energy-northwest.com
David M. Gullott Exelon Generation
4300 Winfield Road
Warrenville IL 60555 Email: David.Gullott@exeloncorp.com
Wesley Sparkman
Southern Nuclear Operating Company
42 Inverness Center Parkway / Bin B237 Birmingham, AL 35242 Email: wasparkm@southernco.com