[[Issue date::May 17, 2018]] | |||
Docket No. 07200039License No. SFGL-21 Mr. Shae Hemingway, ISFSI Manager Connecticut Yankee Atomic Power Company Haddam Neck Plant 362 Injun Hollow Road East Hampton, CT 06424-3099 | |||
SUBJECT: CONNECTICUT YANKEE ATOMIC POWER COMPANY - INDEPENDENT SPENT FUEL STORAGE SECURITY INSPECTION REPORT NO. 07200039/2018401 | |||
==Dear Mr. Hemingway:== | |||
On April 26, 2018, the U.S. Nuclear Regulatory Commission (NRC) performed an Independent Spent Fuel Storage Installation (ISFSI) security inspection at the Connecticut Yankee Atomic Power Company in East Hampton, Connecticut. The inspection covered the October 16, 2002, Interim Compensatory Measures for Dry Independent Spent Fuel Storage Installations Order and was conducted using NRC Inspection Procedure 81311, "Physical Security Requirements for Independent Spent Fuel Storage Installations". | |||
The enclosed inspection report documents the inspection results, which were discussed with you, on April 26, 2018. The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license. | |||
The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings were identified. | |||
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Enclosure contains Sensitive Unclassified Non- Safeguards Information. When separated from Enclosure, the transmittal document is decontrolled. However, the material enclosed herewith contains Security Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. If you choose to provide a response and Security Related Information is necessary to provide an acceptable response, please mark your entire response "Security Related Information - Withhold From Public Disclosure Under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response. | |||
Sincerely,/RA/ Raymond R. McKinley, Chief Plant Support Branch Division of Reactor Safety | |||
===Enclosure:=== | |||
Inspection Report No. 07200039/2018401 (CONTAINS ) (OUO-SRI) | |||
cc w/encl; w/OUO-SRI RPT: J. Lenois, Security Program Manager J. Semanick, State Liaison Officer, State of Connecticut | |||
ML18158A515 (Cover letter only) ADAMS ACCESSION NUMBER: ML18158A536 (Cover letter w/enclosure) (OUO/SRI) Cover Letter X SUNSI Review X Non-Sensitive Sensitive X Publicly Available Non-Publicly Available Cover Letter w/Enclosure X SUNSI Review Non-Sensitive X Sensitive Publicly Available X Non-Publicly Available OFFICE RI/DRS RI/DNMS RI/DRS NAME KHussar RPowell RMcKinley DATE 5/03/18 5/16/18 5/17/18 Letter to Mr. Shae Hemingway from Mr. Raymond R. McKinley dated May 17, 2018 | |||
SUBJECT: CONNECTICUT YANKEE ATOMIC POWER COMPANY - INDEPENDENT SPENT FUEL STORAGE SECURITY INSPECTION REPORT NO. 07200039/2018401 | |||
Distribution w/o encl; w/o OUO-SRI: (via E-mail) D. Lew, RA (R1ORAMAIL RESOURCE) | |||
D. Collins, DRA (R1ORAMAIL RESOURCE) | |||
J. Yerokun, DRS (R1DRSMAIL RESOURCE) | |||
J. Trapp, DNMS (R1DNMSMAIL RESOURCE) | |||
J. Nick, DNMS (R1DNMSMAIL RESOURCE) | |||
D. Screnci, PAO N. Sheehan, PAO J. Greives, SLO D. Tifft, SLO | |||
Distribution w/encl; w/OUO-SRI RPT: K. Hussar, DRS R. McKinley, DRS R. Powell, DNMS D. Huyck, NSIR N. Simonian, NSIR E. Wharton, NSIR B. Desai, DRS, RII S. Orth, DRS, RIII J. Groom, DRS, RIV | |||
}} | }} | ||
Revision as of 18:21, 19 June 2018
| ML18158A515 | |
| Person / Time | |
|---|---|
| Site: | Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png |
| Issue date: | 05/17/2018 |
| From: | Raymond McKinley Plant Support Branch 1 |
| To: | Hemingway S Connecticut Yankee Atomic Power Co |
| McKinley R R | |
| References | |
| IR 2018401 | |
| Download: ML18158A515 (4) | |
Text
May 17, 2018
Docket No. 07200039License No. SFGL-21 Mr. Shae Hemingway, ISFSI Manager Connecticut Yankee Atomic Power Company Haddam Neck Plant 362 Injun Hollow Road East Hampton, CT 06424-3099
SUBJECT: CONNECTICUT YANKEE ATOMIC POWER COMPANY - INDEPENDENT SPENT FUEL STORAGE SECURITY INSPECTION REPORT NO. 07200039/2018401
Dear Mr. Hemingway:
On April 26, 2018, the U.S. Nuclear Regulatory Commission (NRC) performed an Independent Spent Fuel Storage Installation (ISFSI) security inspection at the Connecticut Yankee Atomic Power Company in East Hampton, Connecticut. The inspection covered the October 16, 2002, Interim Compensatory Measures for Dry Independent Spent Fuel Storage Installations Order and was conducted using NRC Inspection Procedure 81311, "Physical Security Requirements for Independent Spent Fuel Storage Installations".
The enclosed inspection report documents the inspection results, which were discussed with you, on April 26, 2018. The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license.
The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings were identified.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Enclosure contains Sensitive Unclassified Non- Safeguards Information. When separated from Enclosure, the transmittal document is decontrolled. However, the material enclosed herewith contains Security Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. If you choose to provide a response and Security Related Information is necessary to provide an acceptable response, please mark your entire response "Security Related Information - Withhold From Public Disclosure Under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.
Sincerely,/RA/ Raymond R. McKinley, Chief Plant Support Branch Division of Reactor Safety
Enclosure:
Inspection Report No. 07200039/2018401 (CONTAINS ) (OUO-SRI)
cc w/encl; w/OUO-SRI RPT: J. Lenois, Security Program Manager J. Semanick, State Liaison Officer, State of Connecticut
ML18158A515 (Cover letter only) ADAMS ACCESSION NUMBER: ML18158A536 (Cover letter w/enclosure) (OUO/SRI) Cover Letter X SUNSI Review X Non-Sensitive Sensitive X Publicly Available Non-Publicly Available Cover Letter w/Enclosure X SUNSI Review Non-Sensitive X Sensitive Publicly Available X Non-Publicly Available OFFICE RI/DRS RI/DNMS RI/DRS NAME KHussar RPowell RMcKinley DATE 5/03/18 5/16/18 5/17/18 Letter to Mr. Shae Hemingway from Mr. Raymond R. McKinley dated May 17, 2018
SUBJECT: CONNECTICUT YANKEE ATOMIC POWER COMPANY - INDEPENDENT SPENT FUEL STORAGE SECURITY INSPECTION REPORT NO. 07200039/2018401
Distribution w/o encl; w/o OUO-SRI: (via E-mail) D. Lew, RA (R1ORAMAIL RESOURCE)
D. Collins, DRA (R1ORAMAIL RESOURCE)
J. Yerokun, DRS (R1DRSMAIL RESOURCE)
J. Trapp, DNMS (R1DNMSMAIL RESOURCE)
J. Nick, DNMS (R1DNMSMAIL RESOURCE)
D. Screnci, PAO N. Sheehan, PAO J. Greives, SLO D. Tifft, SLO
Distribution w/encl; w/OUO-SRI RPT: K. Hussar, DRS R. McKinley, DRS R. Powell, DNMS D. Huyck, NSIR N. Simonian, NSIR E. Wharton, NSIR B. Desai, DRS, RII S. Orth, DRS, RIII J. Groom, DRS, RIV