{{#Wiki_filter:_John Hickaman_-_FS Data Issues     ...                        .Page,1 From:               John Hickman To:                 Yankee, Alice Carson Date:             09/05/2006 4:29:56 PM
{{#Wiki_filter:_John Hickaman_-_FS Data Issues  
.Page,1 From:
John Hickman To:
Yankee, Alice Carson Date:
09/05/2006 4:29:56 PM


==Subject:==
==Subject:==
FSS Data Issues Alice, The following are the data issues that Tom needs resolved:
FSS Data Issues
: Alice, The following are the data issues that Tom needs resolved:
TBN-01 -02 through TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/100cm2 units. The staff cannot determine if the DCGLs are exceeded or not.
TBN-01 -02 through TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/100cm2 units. The staff cannot determine if the DCGLs are exceeded or not.
(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.
(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.
NOL-01 -01 and NYS-12-01 The FSS Reports listed are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.
NOL-01 -01 and NYS-12-01 The FSS Reports listed are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.
The staff cannot locate the scan survey data for NOL-01-01. NOL-01 has four (4) survey units.       ISOCS scan data or a data summary was identified for the other three (3) survey units.
The staff cannot locate the scan survey data for NOL-01-01. NOL-01 has four (4) survey units.
ISOCS scan data or a data summary was identified for the other three (3) survey units.
The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.
The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.
I also attached a WP copy of the same text.
I also attached a WP copy of the same text.
Thanks John CC:                 Thomas Youngblood
Thanks John CC:
Thomas Youngblood


Ic:\temp\GWJ00001.TMP V                                                                                                        Page I Page I.6:\ten~NOW}dOOO1 .TMP Mail Envelope Properties     (44FDDE44.17E:12: 35218)
V I c:\\temp\\GWJ00001.TMP Page I I. 6:\\ten~NOW}dOOO1.TMP Page Mail Envelope Properties (44FDDE44.17E:12: 35218)


==Subject:==
==Subject:==
FSS Data Issues Creation Date          09/05/2006 4:29:56 PM From:                  John Hickman Created By-:          JBH@nrc.*ov Recipients                                       Action              Date & Time comcast.net                                     Transferred          09/05/2006 4:30:20 PM acarson1967 (Yankee Alice Carson) nrc.gov TWGWPO04.HQGWDOO1                               Delivered           09/05/2006 4:30:06 PM THY CC (Thomas Youngblood)                    Opened              09/05/2006 4:31:33 PM Post Office                                      Delivered           Route comcast.net TWGWPO04.HQGWDOO1                                09/05/2006 4:30:06 PM       nrc.gov Files                          Size              Date & Time MESSAGE                        2121              09/05/2006 4:29:56 PM Data issues.wpd                3513              09/05/2006 4:27:16 PM Options Auto Delete:                   No Expiration Date:               N4one Notify Recipients:             Yes Priority:                       Standard ReplyRequested:                 No Return Notification:
Creation Date From:
Created By-:
FSS Data Issues 09/05/2006 4:29:56 PM John Hickman JBH@nrc.*ov Recipients comcast.net PM acarson1967 (Yankee Alice Carson) nrc.gov TWGWPO04.HQGWDOO1 PM THY CC (Thomas Youngblood)
PM Post Office TWGWPO04.HQGWDOO1 Action Transferred Date & Time 09/05/2006 4:30:20 Delivered Opened 09/05/2006 4:30:06 09/05/2006 4:31:33 Delivered Route comcast.net 09/05/2006 4:30:06 PM nrc.gov Date & Time 09/05/2006 4:29:56 PM 09/05/2006 4:27:16 PM Files MESSAGE Data issues.wpd Options Auto Delete:
Expiration Date:
Notify Recipients:
Priority:
ReplyRequested:
Return Notification:
Send Notification when Opened Concealed  
Send Notification when Opened Concealed  


==Subject:==
==Subject:==
No Security:                       tandard To Be Delivered:               Immediate Status Tracking:               I)elivered & Opened
Security:
To Be Delivered:
I Status Tracking:
I Size 2121 3513 No N4one Yes Standard No No tandard mmediate
)elivered & Opened


Ij6hn Hickman - Data- issues.wpd           ..                                                                    Pagel TBN-01 -02 throuqh TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/1 00cm 2 units. The staff cannot determine if the DCGLs are exceeded or not.
Ij6hn Hickman - Data-issues.wpd Pagel TBN-01 -02 throuqh TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/1 00cm 2 units. The staff cannot determine if the DCGLs are exceeded or not.
(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.
(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.
NOL-01 -01 and NYS-12-01 The FSS Reports Iisted are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.
NOL-01 -01 and NYS-12-01 The FSS Reports Iisted are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.

Latest revision as of 04:53, 15 January 2025

E-mail Dated September 5, 2006, to Yankee Atomic Electric Company Forwarding Comments on Final Status Survey Reports
ML063410404
Person / Time
Site: Yankee Rowe
Issue date: 09/05/2006
From: John Hickman
NRC/FSME/DWMEP
To: Carson A
Yankee Atomic Electric Co
References
Download: ML063410404 (3)


Text

_John Hickaman_-_FS Data Issues

.Page,1 From:

John Hickman To:

Yankee, Alice Carson Date:

09/05/2006 4:29:56 PM

Subject:

FSS Data Issues

Alice, The following are the data issues that Tom needs resolved:

TBN-01 -02 through TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/100cm2 units. The staff cannot determine if the DCGLs are exceeded or not.

(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.

NOL-01 -01 and NYS-12-01 The FSS Reports listed are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.

The staff cannot locate the scan survey data for NOL-01-01. NOL-01 has four (4) survey units.

ISOCS scan data or a data summary was identified for the other three (3) survey units.

The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.

I also attached a WP copy of the same text.

Thanks John CC:

Thomas Youngblood

V I c:\\temp\\GWJ00001.TMP Page I I. 6:\\ten~NOW}dOOO1.TMP Page Mail Envelope Properties (44FDDE44.17E:12: 35218)

Subject:

Creation Date From:

Created By-:

FSS Data Issues 09/05/2006 4:29:56 PM John Hickman JBH@nrc.*ov Recipients comcast.net PM acarson1967 (Yankee Alice Carson) nrc.gov TWGWPO04.HQGWDOO1 PM THY CC (Thomas Youngblood)

PM Post Office TWGWPO04.HQGWDOO1 Action Transferred Date & Time 09/05/2006 4:30:20 Delivered Opened 09/05/2006 4:30:06 09/05/2006 4:31:33 Delivered Route comcast.net 09/05/2006 4:30:06 PM nrc.gov Date & Time 09/05/2006 4:29:56 PM 09/05/2006 4:27:16 PM Files MESSAGE Data issues.wpd Options Auto Delete:

Expiration Date:

Notify Recipients:

Priority:

ReplyRequested:

Return Notification:

Send Notification when Opened Concealed

Subject:

Security:

To Be Delivered:

I Status Tracking:

I Size 2121 3513 No N4one Yes Standard No No tandard mmediate

)elivered & Opened

Ij6hn Hickman - Data-issues.wpd Pagel TBN-01 -02 throuqh TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/1 00cm 2 units. The staff cannot determine if the DCGLs are exceeded or not.

(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.

NOL-01 -01 and NYS-12-01 The FSS Reports Iisted are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.

The staff cannot locate the scan survey data for NOL-01 -01. NOL-01 has four (4) survey units.

ISOCS scan data or a data summary was identified for the other three (3) survey units.

The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.