{{#Wiki_filter:Book 13of1 Final Status Survey Final Report Phase VII Appendix Al12 Survey Unit Release Record 9312-0010, Radiologically Controlled Area East Trench South / MWST A&B May 2007
{{#Wiki_filter:}}
 
CYAPCO FINAL STATUS SURVEY RELEASE RECORD NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 Prepared By:    ~1/2/      A~~*K FSS Engineer Date:    4(- 0;-7 Reviewed B;O11OL                1 Iý  Date: 4-L10-4to FSSý gineer Approved By:                          Date:  /C7,4 Tecfnical Support Manager Revision 0
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD TABLE OF CONTENTS
: 1. SURVEY UNIT DESCRIPTION..................................................      3
: 2. CLASSIFICATION BASIS........................................................ 3
: 3. DATA QUALITY OBJECTIVES (DQO).........................................          6
: 4. SURVEY DESIGN............................................................... 10
: 5. SURVEY IMPLEMENTATION..................................................        13
: 6. SURVEY RESULTS............................................................. 14
: 7. QUALITY CONTROL ........................................................... 20
: 8. INVESTIGATIONS AND RESULTS ...........................................        20
: 9. REMEDIATION AND RESULTS...............................................        21
: 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ..................                  21
: 11. DATA QUALITY ASSESSMENT (DQA) ......................................          22
: 12. ANOMALIES..................................................................... 23
: 13. CONCLUSION ................................................................... 23
: 14. ATTACHMENTS................................................................. 23 14.1  Attachment 1- Figures (10 pages including cover) 14.2  Attachment 2- Scan Results (6 pages including cover) 14.3  Attachment 3- Laboratory Data (151 pages including cover) 14.4  Attachment 4- DQA Results (17 pages including covers)
Total 208 Revision 0
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9312-0010 (Radiologically Controlled Area, East Trench South/
MWST A&B) is designated as Final Status Survey (FSS) Class 1 and consists of approximately one thousand three hundred sixty five square meters (1,365 in2 ) of uninhabited land and is located approximately fifteen hundred twenty nine feet (1,529 ft) from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded as follows: land Survey Unit 9312-0009 to the north (called north as oriented with the north to south flow of the Connecticut River), land Survey Units 9312-0009 and 9527-0005 to the east, land Survey Units 9522-0007 to the south, and land Survey Unit 93 12-0002 and 93 12-0007 to the west. The survey unit is located along the east boundary of Survey Area 9312. It is comprised of flat gravel terrain. The eastern boundary is bordered by a steep rock cliff that transitions to a steep soil bank from north to south.
The reference coordinates associated with this survey unit are E013 through E014 by S067 through S071 (refer to "HNP License Termination Plan" (LTP) Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.
: 2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification."
The "Classijfication Basis Summary" conducted for Survey Unit 9312-0010 consisted of:
a) A review of the 10CFR5O.75 (g) (1) database, b) A review of the 'Initial CharacterizationReport" and the "HistoricSite Assessment Supplement,"
c) Historic and current survey records review, d) Visual inspections and a "walkdown."
A review of the "Initialand Supplemental CharacterizationReports" as well as the previous "ClassificationBasis Summaries" was performed.
The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP, Revision 0.
During plant operation, Survey Unit 9312-0010 was a part of the radiological controlled area and the location of significant, radiologically contaminated structures and systems. Structures included the yard crane, primary water Revision 0                                      3
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD storage tank and backup primary water storage tank.
Major demolition and remediation activities began in 2002. All radioactive systems and components located inside the Containment Building, including the reactor vessel, were removed and appropriately packaged and shipped to an approved off-site disposal facility. Interior structural surfaces inside the Containment Building were decontaminated to ensure contamination levels were acceptable for controlled demolition. Interior walls and floors were then demolished and removed. The Containment liner was removed with the exception of the Incore Sump. The dose from residual radioactivity on the remaining steel and concrete in the sump was accounted for in the "Basement Fill Model". The Incore Sump was then filled with grout to the basement floor elevation. The remaining interior surfaces inside the Containment shell were decontaminated.
Following decontamination, the Containment basement was filled with clean soil to the grade of the exterior open land. The above grade portion of the Contairnment structure was then demolished and removed. Confirmatory radiological surveys were performed throughout the demolition process. No above grade structures currently reside within Survey Area 9312.
Outside of the containment shell, soil remediation began around the northeast, northwest and southeast quadrants of the survey unit. A large excavation was created to the north of the Containment that was designated as Excavation #1.
This excavation included the area in the vicinity of the Refueling Water Storage Tank and the Primary Auxillary Building (PAB) corrider. A second large excavation, also designated as Excavation #2 was located over the Service Building footprint. A third excavation, designated as Excavation #3 was located in the area between the Containment Building and Spent Fuel Building (SFB).
As adjacent structures were demolished, soil was excavated and removed. This process continued until bedrock was exposed. Subsurface structures and footings that remained following demolition and excavation include the Containment Mat, the Cable Vault wall, the Service Building east wall, a remnant of the PAB northwest wall, Waste Disposal Building footing and miscellaneous fragments of footings and slabs on the bedrock. As with the Containment basement shell, all excavations were backfilled with clean fill following the performance of a radiological assessment.
This report represents the second of two (2) attempts to FSS this survey unit. An initial FSS survey was performed starting on 0 1-22-07. Subsequent to the completion of this FSS Survey, but prior to the submittal of its Release Record, a remediation campaign was performed on the steep hillside in adjacent survey unit 9312-0009. The remediation efforts were followed by heavy rains that washed a portion of the hill side soils into the portion of the eastern end of this survey unit.
A surveillance of the affected area was performed on 03-15-07. Four (4) biased samples were collected at the location of the highest observed scan readings.
RevisionO0                                            4
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Two (2) of the four (4) samples had on-site sample results in excess of the DCGL, primarily due to the presence of Cs-137, which was determined to be present at concentrations up to 7 pCi/g.
A remediation was performed over the affected area, the remediation survey results indicated that the area was cleaned to levels below the DCGL.
Table 1 -    Basic Statistical Quantities for Cs-137, Co-60 and Sr-90 from the Initial Final Status Survey & Surveillance Soil Sample Population Cs-137              Co-60            Sr-90 (Pci/g)            00/0lg          (Pcilg)
Minimum Value:                  -6.60E-03          -1.09E-02        -2.61E-03 MaiuVle                  .85E+00            1.08E-01        1.15E+00 Ma:4.15E-01                                2.32E-02        1.09E-01 Mda:6.2                    1E-02          1.23E-02        4.5 1E-02 Standard Deviation:            6.52E-0 I          3.43E-02        2.78E-0 I A review of this sample data shows Cs-137, Co-60 and Sr-90 to be the primary radionuclides of concern, with both Cs-137 and Co-60 reported at fairly low concentrations. Sr-90 was the predominant nuclide primarily due to one scan investigation sample result from the initial FSS (sample 9312-0010-0161). The sample population as a whole was evaluated to assess the distribution of the detected radionuclides. The radionuclide distribution percentage for each sample in the population was calculated by dividing the concentration of each detected radionuclide by the total activity concentration in the sample, expressing the abundance of the specific nuclide in the sample compared against the total activity. The mean radionuclide distribution was then calculated by taking the average of the individual sample distribution fractions. The results are provided in Table 2.
Revision 05                                      5
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 2 -      Distribution Fraction for Detectable Radionuclides in Soil Sample Population Detected Radionuclide                        Distribution Fraction Cs-137                                    0.408 Co-60                                    0.047 Sr-90                                    0.545 No additional HTD radionuclides were positively identified in concentrations meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty). Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.
The FSS Engineer performed a visual inspection and walk-down during March 2007 to assess the physical condition of the survey unit, evaluate access points, travel paths and identify potentially hazardous conditions.
This survey area is affected by existing and future groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.
Based upon the identification of radioactive material above the Derived Concentration Guideline Levels (DCGLs), and the need for radiological remediation, it was concluded that there was some probability for residual radioactivity in concentrations greater than the DCGLs, justifying a final survey unit classification of Class 1 (refer to Section 3).
: 3. DATA QUALITY OBJECTIVES (DQO)
FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5. 1-11, "Preparation of Final Status Survey P/an," and the "Mu/ti-Agency Radiation Survey and Site Investigation Manual" (MARS SIM). A summary of the main features of the DQO process are provided herein.
The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis.
Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, Revision 06                                      6
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria.
The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9312-0010 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.
The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.
Equation 1 HTotal=Hs0oii+HExistingGw+/-HFutureGW The total dose under the LTP criteria is twenty-five (25) mremlyr Total Effective Dose Equivalent (TEDE) from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mremlyr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.
This survey unit is considered impacted by future groundwater radioactive contamination, as there are underground foundations containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is bounded by two (2) mremlyr TEDE.
Equation 2 19 mrem/yrT0 t,, = 15 mremlyrs 1 il + 2 mnreM/YrExisting GW+ 2 mremn/yrhFtureGW Revision 07                                      7
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD The allowable dose for soil in this survey unit is fifteen (15) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in fifteen (15) mrem/yr TEDE is designated as the Operational DCGL (DCGLOp), and has been established for the radionuclides of concern as provided in Table 3.
Revision 08                                    8
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 3 -    Radionuclide Specific Base Case Soil DCGLs, Operational DCGLs and Required Minimum Detectable Concentrations (MDCs)
Radionuclide      ()    Base Case Soil          Operational            Required MDC DCGL                  DCGL                    (pC/g) (4)
(PC/g) (2)              (pC/g) (3)
H-3                  4.12E+02                2.47E+02                1.65E+01 C-14                  5.66E+/-00              3.40E+/-00                2.26E-01 Mn-54                  1.74E+01              1.04E+01                  6.96E-01 Fe-55                  2.74E+/-04              1.64E+04                1.I1OE+03 Co-60                  3.8 1E+00              2.29E+/-00                  1.52E-01 Ni-63                  7.23E+02              4.34E+02                2.89E+01 Sr-90                  1.55E+00                9.30E-01                6.20E-02 Nb-94                  7.12E+00              4.27E+/-00                2.85E-01 Tc-99                  1.26E+01              7.56E+00                  5.04E-01 Ag-lO8m.                7.14E+00              4.28E+00                  2.86E-01 Cs-134                  4.67E+00              2.80E+/-00                  1.87E-01 Cs-137                  7.9 1E+00              4.75E+00                  3.16E-01 Eu-152                  1.O1E+01              6.06E+00                  4.04E-01 Eu- 154                9.29E+00              5.57E+00                  3 .72E-0 1 Eu-155                  3.92E+02              2.35E+/-02                  1.57E+01 Pu-238                  2.96E+0 1              1.78E+/-O01                1.18E+00 Pu-239/240                2.67E+0 1              1.60E+0 1                1.07E+/-00 Am-241  ()2.58E+01                              1.55E+/-01                1.03E+00 Pu-241                  8.70E+02              5.22E+02                3.48E+/-01 Cm-2431244                2.90E+0 1              1.74E+0 1                1.16E+/-00 (1)  Bold indicates those radionucidies considered Hard to Detect (HTD)
(2)  The Base Case Soil DCGL(s) are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3)  The Operational DCGL is equivalent to achieving fifteen (15) mrem/yr TEDE (4)  The required MDC is equivalent to achieving one (1) mrem/yr TEDE (5)  Americium-24 1 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed Revision 09                                      9
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Soil samples were collected in 2006 to establish the radiological condition of Survey Unit 9312-0010 for FSS.
Cs-137, Co-60 and Sr-90 were the three (3) radionuclides reported in concentrations with the potential for exceeding the release criteria. The characterization data were used for the survey design and are provided in Table 1.
Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
: 4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5. 1-11, "Preparationof Final Status Survey Plans".
The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.
The DQO process determined that Cs-137, Co-60 and Sr-90 would be the radionuclides of concern in Survey Unit 9312-0010 (refer to Section 3). The characterization surveys did not include any additional HTD radionuclides of concern for this survey unit. As Sr-90 concentrations were determined by direct analysis, surrogate DCGLs were not required as part of the survey design for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs".
Other radionuclides that were positively identified in concentrations greater than the screening criteria during the performance of this FSS would be evaluated to ensure adequate survey design.
As the survey unit is classified as a Class 1 surface soils area, and discrete, elevated areas of contamination was possible, the application of the Elevated Measurement Comparison (EMC) remained an option.
The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.            This approach was conservative since it included background Cs-137 as part of the sample set.
The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Revision 0                                    10
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5. 1-11 to 0. 5 to achieve a relative shift (A/oY) in the range of 1 and 3. The resulting relative shift was 1.5. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10CFR2O, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design. The survey design specified eighteen (18) surface soil samples for non-parametric statistical testing. Based upon a review of the historical information and Characterization Survey data, the acquisition of five (5) judgmental surface soil samples from two (2) areas within this survey unit was deemed appropriate. These two (2) areas included where the remediation was performed and the sample location that indicated an elevated Sr-90 concentration, based on the initial FSS sample results.
The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey." Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 1 area.
Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 4.
Table 4  - Sample Measurement Locations with Associated GPS Coordinates Designation                  Northing                Easting 9312-0010-IOIF                236722.97              668813.41 9312-0010-102F                236696.79              668858.76 9312-0010-103F                236670.61              668904.10 9312-0010-104F                236670.61              668934.33 93 12-0010-105F                236670.61              668964.55 93 12-0010-106F                236644.43              668919.21 93 12-0010-107F                236644.43              668949.44 9312-0010-1 08F                236644.43              668979.67 Revision 0                                      1I I
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 4  -  (continued)
Designation                  Northing                Easting 93 12-0010-109F                236644.43              669009.89 93 12-0010-1IIOF              236644.43              669040.12 9312-0010-IIIF                236618.25              668964.55 9312-0010-1 12F                236618.25              668994.78 9312-0010-113F                236618.25              669025.01 9312-0010-114F                236618.25              669055.24 93 12-0010-1 15F              236592.07              668979.67 9312-0010-1 16F                236592.07              669009.89 9312-0010-1 17F                236592.07              669040.12 93 12-0010-1 18F              236565.90              669025.01 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RAND" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LIP, Table 2-12, "Radionuclides Potentially Presentat Haddam Neck P/ant" and as provided in Table 3.
The LTP requires a minimum of 5% of the samples taken for non-parametric statistical testing be selected for QC evaluation. The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of one (1) soil sample for "split sample" analysis by the off-site laboratory. This location was selected randomly using the Microsoft Excel "RAND" function.
The LTP specifies a required scanning coverage of 100% for outdoor Class 1 areas.
For this Class 1 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 5 provides a synopsis of the survey design.
Revision 0                                    12 1
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 5 - Synopsis of the Survey Design                    _____________
Feature                        Design Criteria            Basis Survey Unit Land Area                  1,365 m2ý            Based on AutoCAD-LT 23                Type 1 and Type 2 errors were Number of Measurements          (18 systematic grid)        0.05, sigma was 0.33 the LBGR was set at 0.5 to achieve a Relative (5 judgmental)            Shift in the range of 1 and 3 Grid Spacing                            9.36 mn            Based on triangular grid Opeatina DCL4.29                pCilg Co-6130        Administratively set to achieve OpeatinalDCG229 ~i/ Co60                      fifteen (15) mremlyr TEDE(1 0.93 pCi/g Sr-90 4.75 pCi/g Cs-137            The Operational DCGL meets the Soil Investigation Level        2.29 pCi/g Co-60            LTP criteria for a Class 1 survey 0.93 pCi/g Sr-90            unit Scan Survey Area                Approximately                The LTP requires 100% area Coverage                        100% of the area            coverage for Class 1 survey units An instrument                This is the recommended response greater            investigation level value from Scan Investigation Level        than the 2,000 cpm          Technical Support Document CY-plus ambient                HP-0239 backgroundII (1) The allowable dose for soil in this survey unit is fifteen (15) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo LSC 06-024)
: 5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under the Final Status Survey Plan (FSSP). The FSSP contained a job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.
A single scan area was established that constituted approximately 100% of the surface area of Survey Unit 93 12-0010. Grid lines, one (1) meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 8,240 counts per minute (cpm) up to 14,000 cpm.
The scan area was established and scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode Revision 0                                                  13
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second.
Approximately 100% of the survey unit was scanned.
Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification. At each sample location, a one (1) meter radius circle was established around the sample flag or paint mark was scanned for elevated radiation levels.
Eighteen (18) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."
Two (2) samples (9312-0010-1 02F and 9312-00 10-111IF) were randomly selected for HTD radionuclide analysis.
The implementation of survey specific quality control measures included the collection of one (1) sample (93 12-0010-1 14F) for "split sample" analysis.
: 6. SURVEY RESULTS All field survey activities were conducted from March 26, 2007 to March 29, 2007.
The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations. Scan results are provided in Attachment 2.
Table 5 - Scan Results for Sample Measurement Locations Sample        Highest Logged        Action Level                      (2)
Measurement            Reading              (kcpm)        > Action Level()
Location              (kcpm) 101                14.8                15.2                NO 102                12.9                13.4                NO 103                12.9                14.3                NO 104                10.3                12.0                NO=
Revision 0                                      14
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 5  -  (continued)                                            ________
Sample              Highest Logged          Action Level()
Measurement                Reading                  (kp)          >  Action Level(2 Location                  (kcpm)________
105                    9.49                    11.5                  NO 106                    8.79                    11.2                  NO 107                    9.53                    11.2                  NO 108                    12.2                    13.4                  NO 109                    13.1                    13.4                  NO 110                    9.37                    9.88                  NO 111                    11.0                    12.1                  NO 112                    11.1                    12.1                  NO 113                    10.2                    11.7                  NO 114                    10.2                    10.5                  NO 115                    11.6                    12.4                  NO 116                    11.0                    12.4                  NO 117                    11.2                    12.2                  NO 118__11.5                                  12.3                  NO 11          3114.0                                      NO 12          4815.7                                      NO 12          3112.7                                      YES( 3 )
122                    10.8                    12.8                  NO 123                    11.0                    14.1                  NO (1) The action level is based on a measurement above ambient background.
(2) The FSS plan requires movement of the sample measurement location to the area within the I meter radius yielding the response above the action level.
(3) This sample location was moved to the highest observed gamma reading within the 1-in scan circle.
The scan areas, that comprised approximately 100% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on March 28, 2007.
Revision 0                                            15
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Sixty six (66) scan strips were initially established in this survey unit. Three (3) elevated measurement locations were identified during scanning. Table 6 provides an overview of the scan area survey. Scan results are provided in .
Table 6 - Scan Area Results Highest        Action Logged        Lvl          Elevated Reading              Investigation Scan Strips      Reading        Le elI          eniicpi    n(2mam                  l (kcpm)      _______
1 thru 13          14.43          12.9    9312-10-ER-00-13-1            9312-0010-124-I 14 thru 20          22.4          12.0    9312-10-ER-00-20-1            93 12-0010-125-I 21lthru 49          12.38          11.9    9312-l0-ER-00-49-l            9312-0010-126-1 49 thru 66          11.5          13.8              N/A                        N/A (1) The action level is based on a measurement above ambient background plus 2,000 cpm (2) ER is an abbreviation associated with the barcodes used in the field where ER stands for Elevated Reading.
The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the eighteen (18) samples collected for non-parametric statistical testing, the associated field splits using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required MDCs.                Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty). However, Cs-137 was the only gamma-emitting radionuclide reported in concentrations exceeding the de-selection criteria.
Cs-137 was identified in twelve (12), Co-60 was identified in one (1) and Sr-90 in two (2) of the eighteen (18) samples collected for non-parametric statistical testing. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels higher than expected environmental levels for Cs- 137 within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063. A summary of the eighteen (18) samples collected for non-parametric statistical testing results is provided in Table 7.
Revision 0                                              16
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 7 - Summary of Gamma Spectroscopy Results for Surface Soil Samples Comprising the Statistical Sample Population SmlNubrCs-137                                        Co-60 SamleNumerpCiig                                      pCilg 9312-0010-IOIF                2.56E-01                    3.48E-02 9312-0010-102F                1.60E+00                    0.OOE+/-00 9312-0010-103F                1.91E+/-00                    0.OOE+00 9312-0010-104F                1.44E-01                    8.09E-03 93 12-0010-105F                8.70E-02                  -5. 15E-03 9312-0010-106F                2.88E-02                      1.74E-02 9312-0010-107F                0.OOE+/-00                    -9.39E-03 9312-0010-108F                4.18E-02                    2.13E-02 9312-0010-1 09F              2.76E-0 1                    2.92E-02 9312-0010-11OF                4.30E-01                      1.63E-02 9312-0010-111F                1.91E-02                  -5.55E-03 9312-0010-112F                -2.35E-02                  -2.30E-03 9312-0010-113F                6.26E-02                    -1.72E-02 9312-0010-114F                4.96E-01I                  0.00E+/-00 9312-0010-115SF                7.48E-03                    1.65E-03 9312-0010-1 16F              -3.85E-03                    2.50E-03 9312-0010-117F                2.91E-01                    2.2 1E-02 9312-0010-11 8F                6.1 9E-02                  -2.46E-03 In addition to Cs-137 and Co-60, Sr-90 was also identified during the DQO process as a radionuclide of concern. Subsequently, all samples were subjected to analysis by gas proportional counting for Sr-90. All analyses met the required minimum MDC.
Sr-90 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in two (2) of the eighteen (18) samples collected for non-parametric statistical testing. The results of the Sr-90 analysis for the statistical sample population are provided below in Table 8.
Revision 0                                        17
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 8 - Summary of Sr-90 Analysis Results for Surface Soil Samples Comprising the Statistical Sample Population Sample Number                              Sr-90 pCilg 9312-0010-IOIF                            1.97E-02 9312-0010-102F                            2.53E-02 9312-0010-103F                            2.54E-02 9312-0010-104F                            3.70E-02 9312-0010-105F                          -1.05E-02 9312-0010-106F                          -2.23E-02 9312-0010-107F                          -1.55E-02 9312-0010-108F                            8.14E-03 9312-0010-109F                            1.91E-02 9312-0010-IIOF                            -1.05E-02 9312-0010-IIIF                            2.40E-03 9312-0010-112F                            1.05E-02 9312-0010-113F                            -1.63E-02 9312-0010-114F                            2.75E-02 93 12-0010-1 15F                        -6.57E-03 9312-0010-116F                            1.16E-03 9312-0010-117F                            1.30E-02 9312-0010-118F                            5.96E-03 In addition to Sr-90, the off-site laboratory also processed, as required by the sample plan, two (2) samples for the full suite of HTD radionuclides as specified in LTP, Table 2-12, "RadionuclidesPotentially Present at Haddam Neck Plant" and as provided in Table 3. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide Revision 0                                      18
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD and the measurement method. All analyses performed met the required minimum MDC. In one (1) sample, C-14 was detected at two (2) percent of the DCGL which is below the selection criteria discussed in Section 2. No additional HTD radionuclides were positively identified (i.e., a result greater than two (2) standard deviations uncertainty). The "sum-of-fractions"~ or "unity rule."
is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The combination of the fractions of each detected radionuclide against their respective Operational DCGL must be less than or equal to one (1). The unity rule is:
Equation 3 Cl-        C2            Cn DCGL,      DCGL 2        DCGL, Where:  Cn =  concentration of radionuclide n and DCGLn DCGL of radionuclide n.
The results of the unity rule calculation for the radionuclides of concern in the statistical sample population for Survey Unit 9312-0010 are provided in Table 9 below.
Table 9 -        Results of Unity Calculation for Surface            Soil    Samples Comprising the Statistical Sample Population Sample Number                Fraction of the Operational DCGL1' )(2 )        unity
___________            Cs-137          Co-60            Sr-90 9312-0010-IOIF              2.56E-01        3.48E-02        O.OOE+00      6.92E-02 9312-0010-1 02F            1.60E+00        O.OOE+/-O0        2.53E-02      3.64E-0 1 9312-0010-103F            1.9 1E+00        O.OOE+00        2.54E-02      4.30E-01 9312-0010-1 04F            1.44E-0 1      8.09E-03        3 .70E-02      7.37E-02 9312-0010-1 05F            8.70E-02        0.OOE+00        0.OOE+00      1.83E-02 9312-0010-1 06F            2.88E-02          1.74E-02      0.OOE+O0      1.37E-02 9312-0010-1 07F            0.00E+/-00        0.OOE+/-00        O.OOE+00      0.OOE+00 93 12-0010-108F            4.1 8E-02        2.13E-02        8.14E-03      2.69E-02 93 12-0010-109F            2.76E-01        2.92E-02        1.91E-02      9. 15E-02 9312-0010-IIOF            4.30E-01          1.63E-02      0.00E+00      8.64E-02 Revision 0                                      19
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD 9312-0010-111 F            1.91E-02          0.OOE+00          2.40E-03        6.61E-03 9312-0010-1 12F          0.OOE+/-00            0.OOE+00          1.05E-02        1.13E-02 9312-0010-113F            6.26E-02          0.OOE+00          0.OOE+00          1.32E-02 9312-0010-114F            4.96E-01I          0.OOE+00          2.75E-02        1.34E-01 9312-0010-115F            7.48E-03            1.65E-03        0.OOE+/-00          2.30E-03 9312-0010-1 16F          0.OOE+/-00            2.50E-03          1.16E-03        1.09E-03 9312-0010-1 17F            2.9 1E-0 1          2.2 1E-02        1.30E-02        8.50E-02 9312-0010-11 8F            6.1 9E-02          0.OOE+/-00          5 .96E-03        1.84E-02 (1) The Operational DCGL from Table 2 is 4.75 pCilg for Cs-137, 2.29 pCi/g for Co-60 and 0.93 pCi/g for Sr-90 to achieve fifteen (15) mrem/yr TEDE respectively.
(2) Negative results (results whose values were less than zero) were set to zero.
: 7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. One sample location was selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey ". There was acceptable agreement between the field split results.
The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachments 3 and 4 for data and data quality analysis results
: 8. IN4VESTIGATIONS AND RESULTS Three (3) investigative samples were collected from locations exhibiting elevated scan measurements and (5) judgmental samples were taken from the survey area.
Four (4) of the judgmental samples were taken from the vicinity of the area that was subjected to remediation. The remaining judgmental sample was taken from the location where an elevated level of Sr-90 had been detected in the initial FSS.
The investigation samples are denoted as shown in Table 6, with the investigative sample results, and judgmental sample results shown in Table 10 below.
Revision 0                                            20
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD Table 10    -  Investigative and Biased Sample Results Sampe Nuber              Cs-137          Co-60        Sr-90        UiyFato Sampe NuberpCi/g                            pCilg        pCilg        Ui~ rcin" 9312-0010-1 19B          2.25E+00        1.25E-01      7.53E-03          5.37E-01 9312-0010-120B            3.71E-01        1.50E-02      1.28E-04          8.49E-02 93 12-0010-121B          2.34E-01        1.35E-02      1.58E-02          7.22E-02 93 12-0010-122B          3.35E-02        1.02E-02      9.06E-03          2. 13E-02 9312-0010-1 23B          3 .40E-0 1      8.95E-03      2.29E-02          1.OOE-0 1 9312-0010-1241            1.63E-0 1      1.95E-02      1.99E-02          6.43E-02 9312-0010-1251            3.54E-01I      1.48E-02      6.32E-02          1.49E-01I 9312-0010-1261        12.86E-02      i-2.91E-02      -9.05E-03          -1.64E-02 (1) The Operational DCGL from Table 2 is 4.75 pCilg for Cs-137, 2.29 pCi/g for Co-60 and 0.93 pCi/g for Sr-90 to achieve seventeen (15) mremlyr TEDE respectively.
: 9. REMEDIATION AND RESULTS Radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to FSS. All excavations were characterized and backfilled with "clean" fill prior to performing FSS. In the area where remediation occurred, the ground area is comprised of barren dirt with no vegetation, and the soils have been graded relatively flat to the corresponding elevation of the adjacent survey units. The results for Cs- 137 following remediation were well below the Operational DCGL provided in Table 3. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.
: 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the Final Status Survey Plan.
Revision 0                                          21
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD
: 1. DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency. The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.
Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.
Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs. The basic statistical quantities for the statistical sample population are provided below in Table 11.
Table 11  - Basic Statistical Quantities for Cs-137, Co-60 and Sr-90 from the Final Status Survey Cs-137            Co-60              Sr-90 pCi/g            pCi/g              pCi/g DCGL,,p:                        4.75              2.29                0.93 Minimum Value:              -2.35E-02        -1.72E-02          -2.23E-02 Maximum Value:              1.9 1E+00          3.48E-02            3.70E-02 Mean:                        3.16E-0lI        6.18E-03            3.28E-03 Median:                      7.48E-02          8.25E-04            4.18E-03 Standard Deviation:          5.48E-0lI          .42E-02            1.85E-02 The range of the data, about 3.0 to 3.5 standard deviations for both radionuclides, was not a particularly large variation. The difference between the mean and median was about 40% to 60% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates a slight to diminishing skewness as confirmed by the calculated skew of 2.13, 0.58 and 0.26 for Cs-137, Co-60 and Sr-90 respectively.
Revision 0                                    22
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD All data, assessments, and graphical representations are provided in Attachment 4.
: 12. ANOMALIES No anomalies were noted in the performance of this Final Status Survey.
: 13. CONCLUSION Survey Unit 93 12-0010 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.
All identified radionuclides of concern were used for statistical testing to determine the adequacy of the survey unit for FSS.
The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 1.
The dose contribution from soil is 1.2 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.
This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mremlyr TEDE.
This survey unit is considered impacted by future groundwater radioactive contamination, as there are underground foundations containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is bounded by two (2) mremlyr TEDE.
The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity will not exceed 5.2 mremlyr TEDE.          Therefore, Survey Unit 9312-0010 is acceptable for unrestricted release
: 14. ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0                                    23
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 1 (FIGURES)
Revision 0
 
Olt 4,
Refwo Cworvhel*wt      DpWlI&-"di NOrAhkg - 2=37=302 / Eaft" -
6673"5.7
                                                            ,76J    }1~ ~
IT 1I j-CONNNCITCU ArI*rJ Connecticut Yankee Atomic Power Company Unit 9312-0010 CY Site Map With Reference To Survey
 
9527-0005 Legend 9527-0006                                            109 114 105                    113            No-e 108                11 0      5        30 MGZZZr=Fed 104                          112                  Note Coordinate am in 107                    116 NAD2 7 Connecticut State PlaneSystem 111            11 106                          115
  '2-0002                                                      7 Connecticut Yankee Atomic Power Company SU9312-0010 FinalStatus Survey Design
 
9-75.2A7-0005                                      0 Legend
                                                                                                                  = Sample Point 9527-0006                                    087              0.2 76 0.063 0.296                      0 Notes 15          30 Notes
                                                                                                            -  Coordinatesamein NAD2 7 Connecticut State Plane System 0.1440.000-0.024 93
                                                                                                                - Ail results ame 09 repoledinp~ig.
1.91                  000-0.                          004~,
0.019                      U. VLL~
1 0.256    1.60                      0.029                      0.007 r
9312 MOU-1 U
: 93. 12-0002                                                                                p -.-. ~
Connecticut Yankee Atomic Power Company            Date: Apfil2007 i                                      I Figure3 SU 9312-0010 Cs-l37PostingPlot                        D.Randall I                                        I
 
I 975J2A7-0005                          0 7Sample        Point 9527-0006                                    -0050.029 -0.002 0.0                        0 Notes 15          30 No-e
                                                                                                -Coordinates  amein NAD27Conneeticut 2      state Plane System 930.008
                                                                  ~-0.02102
                                                                                                - All results ame
                                                -0.009                                        raported inpCilg.
0.017              -U.VUb 0.002 1  0.035      0.00 9312 Mt Olt 93.12-0002                                        IJ Date. April2007 Connecticut Yankee Atomic Power Company      I Fi~gure 4 SU 9312-0010 Co-60 Posting Plot                      D. Randall I
 
952ý9527-0.005                                                                  0      zSample Point 9527000                                10010.019 -0.01600L                      0 Notes 15 No-e 30
                                                                                              - Coordinates arc in NAD27Connecbcut
                                                              ~~0.0    110.O                  State Plane System i009
                                                                                                - All resultsam 93 reportdin pcilg.
0.025                -0.016                    -0.014nn 0.002 1 -0.020      0.025                    -0.022                    -0.007 93(1(111/
S9312-0002                                            ._____
Date: April2007 Connecticut Yankee Atomic Power Company    I Figure5 SU 9312-0010 Sr-90 Posting Plot                      D. Randall I                      .1.
 
9527-0005 Leg end 125              BiasedSamples 0
9527-0006                                126 O0 Investigation Sample Notes 123                                  0        15        30 122                                            No-e 124    Coordinatesare in NAD27 Connecticut State PlaneSystem 119 ii
  '2-0002                                  '312-000 Connecticut Yankee Atomic Power Company SU 9312-0010 FinalStatus Survey Design
 
I 4-957-0005 9527-0006034 Biase Samples 0
O0 Inveadgat on Samples Notes 0        15          30 0023440.34                                                              Notes Feet All values amein P019g.
9309.3712.25" II 93512 -(J(J1(
93412-0002                                              312I000 I                              4 Figure 7 Connecticut Yankee Atomic PowerCompany      i Date: April2007 SU 9312-0010 Cs-13 7 Posting Plot              D. Randall I
 
9527-0005 Letend 952 7-0006                                              0020.1                            0 O0 Biasd Samples nveotiaton Sample Notes 0    15          30 SFmt Nowe 0.015                                0.02~P        All values am i pa'lg.
09 931TIf                01 I
                    ====f 93512 93412-0002                                                -9312-0007 I                            4                            . -i Date: April2007 Connecticut Yankee Atomic Power Company                        I Figure 8 SU 9312-0010 Co-60 PostingPlot        I D. Randall I
 
9527-0005 Biased Samples 0
9527-0006                                -0.009 O 0 Investigaton Notes SIMPles 0.023                                0        Is        30 F.&
0.009                                        Notes
: 0. 021    All values amein pCi'g.
93)12-0002                                          0007 Connecticut Yankee A tomic Power Company SU 9312-00 10 Sr-90 PostingPlot
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)
Revision 0
 
9312-0010 Sample Location Scans Alarm  >Alarm E-600 Probe Level  Level  SIN Survey Location          Log Date Time          Reading                              SIN 9312-1 0-BL-00-1 01-0    3/26/2007 10:31        1.35E+04                      1117 1014 9312-1 0-SL-00-1 01-0    3/26/2007 10:32        1.48E+04 I1.52E+04            1117 1014 9312-1 0-BL--00-1 02-0                            1.8E+04                      1117  1014 3/26/2007      10:33 9312-1 0-SL-00-1 02-0                          1 .29E+04 1.34E+04            1117  1014 3/26/2007      10:35 9312-1 0-BL-00-1 03-0                          I1.27E+04                      1117  1014 3/26/2007      10:35 9312-1 0-SL-00-1 03-0                          1 .29E+04 1 .43E+04            1117  1014
                        -3/26/2007-  -10:37-
-93i2--i0OBL-00-1-040-G                        I l--05E+04-                          ~-1-01                          ~3/26/2 007                                        ~1117 9312-1 0-SL-00-1 04-0                  10:40  1.03E+04 1.20E+04                    1014 3/26/2007                                            1117 9312-1 0-BL-00-1 05-0                  10:41  1.01 E+04                            1014 3/26/2007                                            1117 9312-1 0-SL-00-1 05-0                  10:43  9.49E+03 1.15E+04                    1014 3/2 6/2 007                                          1117 9312-1 0-BL-00-1 06-0                  10:45  9.75E+03                              1014 3/26/2007                                            1117 9312-1 0-SL-00-1 06-0                  10:46  8.79E+03 1.12E+04                    1014 3/26/2007                                            1117 9312-1 0-BL-00-1 07-0                  10:48  9.83E+03                              1014 3/26/2007                                            1117 9312-1 0-SL-00-1 07-0                  10:50  9.53E+03 1.12E+04                    1014 3/26/2 007                                          1117 9312-1 0-BL-00-1 08-0                  10:52  1.18E+04                              1014 3/26/2007                                            1117 9312-1 0-SL-00-1 08-0                  10:54  1 .22E+04 1.34E+04                    1014 3/26/2007                                            1117 9312-1 0-BL-00-1 09-0                  10:55    1.18E+04                            1014 3/26/2007                                            1117 9312-1 0-SL-00-1 09-0                  10:57    1.31 E+04 1.34E+04                  1014 3/26/2007                                            1117 9312-1 0-BL-00-1 10-0                  10:58  8.56E+03                              1014 3/26/2007                                            1117 9312-1 0-SL-00-1 10-0                  10:59  9.37E+03 9.88E+03                    1014 3/26/2007                                            1117 9312-10O-BL-00-1 11 -0                11:01    1.06E+04                            1014 3/26/2007                                            1117 9312-10O-S L-00-1 111-0                11:02    1.10E+04 1.21 E+04                  1014 3/26/2007                                            1117 9312-1 0-BL-00-1 12-0                  11:03    I1.06E+04                            1014 9312-1 0-S L-00-1 12-0  3/26/2007                                            1117 11:04    1.I11E+04 1.21 E+04                  1014 3/26/2007                                            1117 9312-1 0-BL-00-1 13-0                  11:05    1.03E+04                            1014 3/26/2007                                            1117 9312-1 0-SL-00-1 13-0                  11:06    1.02E+04 1.17E+04                    1014 3/26/2007                                            1117 9312-10O-BL-00-1 14-0                  11:07    9.14E+03                            1014 3/26/2007                                            1117 9312-1 0-SL-00-1 14-0                  11:09    1 .02E+04 1.05E+04                  1014 Page 1 of 2
 
9312-0010 Sample Location Scans
.9312-10-BL-00-1 15-0  .3/26/`20071 11:10    1.1019'E'+014            .11014, 9312-1 0-SL-00-1 15-0  3/26/2007 11:12        1.16E+04 1.24E+04  1117 1014 1117 9312-10O-BL-00-1 16-0  3/26/2007    11:12    1 .09E+04                1014 9312-10-SL-00-1 16-0  3/26/2007    11:14    1.I1OE+04 1.24E+04  1117 1014 3/6/00                                    1117 9312-1 0-BL-00-1 17-0                        1 .07E+04                -10 14......
9312-10O-SL-00-1 17-0  3/26/2007    11:15                        1117 1014 1 .12E+04 1.22E+04 3/26/2007    11:17                        1117 1014 9312-1 0-BL-00-1 18-0                        1 .08E+04 3/26/2007    11:17                        1117 1014 9312-10O-SL-00-1 18-0                        1.15E+04 I1.23E+04 1- BL------
--------          9-  3/26/2007    11:19                        1117 1014 9312-10O-SL 119-0                        1.24E+04 3/26/2007    11:20                        1117 1014 1.31 E+04 1.40E+04 9312-1 0-SL-00-1 20-0  3/26/2007    11:21                        1117 1014 9312-1 0-SBL-00-1120-0                        1 .40E+04 3/26/2007    14:37                        1117 1014 1.48E+04 1.57E+04 9312-1 0-BL-00-121-0  3/26/2007    14:37                        1117 1014 9312-1 0-SL-00-1 21-0                        1.12E+04 3/26/2007    14:38                        1117 1014 1.31 E+04 I1.27E+04 9312-1 0-BL-00-122-0  3/26/2007    14:39                        1117 1014 9312-1 0-SL-00-1 22-0                        1.13E+04 3/26/2007    14:39                        1117 1014 1.08E+04 1.28E+04 93 12-1 0-SL-00-1 22-0 3/26/2007    14:39                        1117 1014 9312-1 0-SL-00-1 23-0                        I1.25E+04 3/26/2007    14:40                        1117 1014 1 .10E+04 1.41 E+04 Page 2 of 2
 
9312-0010 Scan Results Log                              Action Survey Location          Log Date Time          Probe SIN Reading Level            Units E-600 SIN 9312-1w G-BC-00O-O -0O                                1004 I1.33E+04                -cpm        1111 3/28/2007    8:04:00 9312-10-SC-00-01-0                                    1004 1.15E+04      I1.53E+04 cpm          1111 3/28/2007    8:05:00 9312-1 G-BC-00-02-0                                  1004 1.12E+04                  cpm        liii 3/28/2007    8:05:00 93 12-1 0-SC-00-02-0                                  1004 1 .07E+04      1.32E+04 cpmn          1111 3/28/2007    8:07:00 9312-1 0-BC-00-03-0                                  1004 8.24E+03                  cpm        ilil 3/28/2007 9312-1 O-SC-00-03-0                    8:11:00      1004 9.80E+03      1.02E+04 cpm          1111 9311-2-1 G-C--0---O-4-0  3/28/2007                  16004:                        cprn        I III 8:12:00 9312-1 0-SC-0O-04-0      3/28/2007                  1004 1.16E+04      1.17E+04 cpm          1111 8:17:00 9312-1 0-BC-00-05-0      3/28/2007                  1004 I1.24E+04                cpm        1111 8:18:00 9312-1 0-SC-a 0-05-0      3/28/2007                  1004 I1.43E+04      1.44E+04 cpm          1111 8:219:00 9312-1 O-BC-0O-06-0      3/28/2007                  1004 1.25E+04                  cpm        1111 8:21:00 9312-1 G-SC-00-06-0      -3/28/2007                  i1004 1.22E+04      1.45E+04 cpm          liii 8:23:00-
-93i 2-1-0-80C-00-070-0.-  3/28/2007                  -4004-41.05E+04-                          -i-i--li-.
                                        ~8:27:00 931 2-1G-SC-0O-07-0      ~3/28/2007-                  1004 1.IOE+04      1.25E+04 cpm          II 1~1 8:27:00 9312-1 G-BC-00-08-O      3/28/2007                  1004 1 .03E+04                cpm        1111 8:31:00 9312-1 0-SC-0O-08-G      3/28/2007                  1004 1.1SE+04      1.23E+04 cpmn          liii 8:31:00 9312-1 G-BC-00-09-0      3/28/2007                  i1004 I1.22E+04                cpm        ilil 8:32:00 9312-1 0-SC-a 0-09-0      3/28/2007                  1004 1.32E+04      1.42E+04 cpm          1111 8:34:00 9312-10O-BC-0O-I 0-0      3/28/2007                  1004 I1.40E+04                cpm        1111 8:37:00 9312-10-SC-00-10-0        3/28/2007                  1004 I1.23E+04      1.60E+04 cpm          1111 8:40:00 9312-10O-BC-GO-il1 -0    3/28/2007                  1004 1.09E+04                  cpm        1111 8:41:00 9312-10O-SC-00-1 1-0      3/28/2007                    1004 I1.08E+04    1.29E+04 cpm          1111 9:50:00 9312-1 O-BC-00-1 2-0      3/28/2007                    1004 1.23E+04                cpm        1111 9:50:00 9312-10O-SC-Go-I 2-0      3/28/2007                    1004 I1.22E+04    1.43E+04 cpmn          1111 93 12-1 0-BC-0O-I 3-0    3/28/2007    10:14:00        1004 I1.09E+04                cpm        1111 9312-10O-SC-GO-i 3-0      3/28/2007    10:20:00        1004 1.02E+04      I1.29E+04 cpm          liii 93i 2-1 0-ER-00-1 3-1    3/28/2007    7: 16:00      1004 I1.44E+04                cpm        1111 9312-1 0-BC-0G-14-G      3/29/2007    10:21:00        1004 1.07E+04                cpm          1111 9312-i G-SC-00-1 4-0      3/28/2007    10:25:00        1004 I1.09E+04      1.27E+04 cpmn          1111 9312-1 0-BC-00-1 5-0      3/28/2007    10:26:00        1004 1.03E+04                cpm          1111 9312-1 0-SC-0O-i 5-0      3/28/2007    10:29:00        1004 I .OGE+04      I1.23E+04 cpmn        1111 93i12-1 O-BC-00-1 6-0    3/28/2007    10:31:00        1004 9.27E+03                cpm          1111 9312-10O-SC-0O-I 6-0      3/28/2007    10:36:00        1004 9.33E+03      1.13E+04 cpmn          liii 9312-10O-BC-00-1 7-0      3/28/2007    10:38:00        1004 1.01 E+04                cpm          1111 9312-1 0-SC-00-I 7-0      3/28/2007    10:40:00        1004 9.82E+03      1.21 E+04 cpmn        1111 9312-1 0-BC-00-1 8-0    3/28/2007    10:41:00        1004 1 .03E+04                cpm        1111 9312-10O-SC-GO-I 8-0      3/28/2007    10:48:00        1004 9.64E+03      1.23E+04 cpm          liii 9312-1 G-BC-00-1 9-0    3/28/2007    10:49:00        1004 9.46E+03                  cpm        1111 9312-i O-SC-0 0-1 9-0    3/28/2007    10:54:00        1004 9.I1OE+03      1.15E+04 cpm          illi 9312-i 0-BC-00-20-0      3/28/2007    10:56:00        1004 9.98E+03                  cpm        1111 9312-10O-SC-00-20-0      3/28/2007    11:02:00        1004 9.63E+03      1.20E+04 cpmn          1111 93i12-1 0-ER-0O-20-1      3/28/2007      7:17:00      1004 2.24E+04                  cpm        liii 9312-1 0-BC-00-211-0    3/29/2007    11:04:00        1004  I1.08E+04                cpm        1111 9312-i 0-SC-00-211-0    3/28/2007    11:10:00        1004 9.73E+03      I1.28E+04 cpmn        1111 9312-1 0-BC-GG-22-O      3/28/2007    11:11:00        1004 9.96E+03                  cpm        1111 9312-1 O-SC-0O-22-0      3/28/2007    11:16:00        1004 9.73E+03      1.20E+04 cpmn          1111 9312-I 0-BC-00-23-G      3/28/2007    11:18:00        1004 9.99E+03                  cpm        liii 9312-I G-SC-G0-23-0      3/28/2007  *11:21:00        1004 9.53E+03      1.20E+04 cpm          1111 9312-1 O-BC-00-24-0      3/28/2007  *11:23:00        1004 9.69E+03                  cpm        1111 9312-10-SC-00-24-0                    11:27:00        1004 9.55E+03      1.17E+04 cpmn          1111 Pagel of 3
 
9312-0010 Scan Results 9312-10O-B0-00-25-0    3/28/2007  11:30:00        1004 1.04E+04                cPM  1111 9312-1 0-SC-00-25-0    3/28/2007    11:32:00      1004 9.81 E+03    1.24E+04 cpm  1111 9312-1 0-80-ý00-26-0  .3/28/2007  11:33:00        1004 9.42E+03                cPM *1111 9312-10O-S0-00-26-0    3/28/2007    11:36:00      1004 9.01E+03      1.14E+04 cpm  1111 9312-1 0-8 C-00-27-0  3/28/2007    12:55:00      1004 9.38E+03                cPM  1111 93 12-1 0-SC-00-27-0  3/28/2007  13:01 :00      1004 9.51 E+03    1.14E+04 cpm  1111 9312-1 0-BC-00-28-0    3/28/2 007  13:03:00      1004 1.02E+04                cPM  1111 9312-1 0-SC-00-28-0    3/281/2007  13:07:00        1004 9.91 E+03    1.22E+04 cpm  1111 9312-10O-80-00-29-0                113:109:00:    1004 14.08E+.            cpm  1111 3/28/2007 9312-10O-50-00-29-0                13:17:00      1004 9.91 E+03    1.28E+04 cpm  1111 3/28/2007 13:19:00        1004 1.08E+04                cPM  1111 9312-1 0-BC-00-30-0    3/28/2007 13:23:00      1004 1.13E+04      1.28E+04 cpm  1111 931 2-1 0-BC-00-310-0  3/28/2 007 9312-1 0-SC-00-31 -0                13:24:00      1004 9.80E+03                cPM  1111 3/28/2007 13:28:00      1004 9.92E+03      1.18E+04 cpm  1111 3/28/200.7-93 12-1 0-SC-00-31-0              -13:29:00-      1-004--9.87E.+03--              Ai11~
3/28/2007-
~931 2-1 0=BC-00-32=0-              13:33:00      1004 1.03E+04      1.19E+04 cpm  1111 3/28/2007 9312-1 0-SC-00-32-0                13:34:00      1004 1.01 E+04              cpm  1111 3/28/2007 9312-1 0-BC-00-33-0                13:39:00      1004 1.02E+04      1.22E+04 cpm  1111 3/28/2007 9312-1 0-SC-a 0-33-0                13:40:00      1004 9.93E+03                GPM  1111 3/28/2007 9312-1 0-BC-00-34-0                13:44:00      1004 1.01 E+04    1.21E+04 cpm  1111 3/28/2007 9312-10O-50-00-34-0                13:46:00      1004 1.03E+04                cPM  1111 3/28/2007 9312-10O-80-00-35-0                13:50:00      1004 1.I1OE+04    1.23E+04 cpm  liii 3/28/2007 9312-1 0-SC-00-35-0                13:50:00      1004 1.03E+04                cPM  1111 3/28/2007 9312-10O-80-00-36-0                13:54:00        1004 1.06E+04      1.23E+04 cpm  1111 3/28/2 007 9312-10O-S0-00-36-0                13:55:00      1004 1.05E+04                cPM  1111 3/28/2007 9312-10O-80-00-37-0                13:59:00        1004 1.09E+04      1.25E+04 cpm  1111 3/28/2007 9312-10O-SC-00-38-0                13:59:00      1004 1.04E+04                cPM  1111 3/28/2007 9312-1 0-BC-00-38-0                14:02:00      1004 1.05E+04      1.24E+04 cpm  1111 3/28/2007 9312-10O-S 0-00-38-0                14:04:00      1004 1.01E+04                cpm  1111 3/28/2007 9312-1 0-BC-00-39-0                14:05:00      1004 1.OOE+04      1.21E+04 cpm  1111 3/2 8/2 007 9312-1 0-SC-00-39-0                14:06:00      1004 1.01IE+04              cPM  1111 3/28/2007 9312-1 0-BC-00-410-0                14:08:00      1004 1.03E+04      1.21 E+04 cpm  1111 3/28/2007 9312-10O-SC-00-410-0                14:08:00      1004 1.OOE+04                cpm  1111 3/28/2007 9312-10O-80-00-41-0                14:10:00      1004 1.15E+04      1.20E+04 cpm  1111 3/28/2007 9312-1 0-SC-00-41-0                14:11:00      1004 1.09E+04                cpm  1111 3/28/2007 9312-1 0-BC-00-42-0                14:13:00      1004 1.06E+04      1.29E+04 cpm  1111 3/28/2007 9312-10O-50-00-42-0                14:13:00      1004 1.07E+04                cpm  1111 9312-10O-80-00-43-0    3128/2007 14:16:00      1004 1.22E+04      1.27E+04 cpm  1111 3/28/2007 9312-1 0-SC-00-43-0                14:16:00      1004 1.14E+04                cpm  1111 3/28/2007 9312-1 0-BC-00-44-0                14:18:00      1004 1.08E+04      1.34E+04 cpm  1111 3/28/2007 9312-10O-SC-00-44-0                14:19:00      1004 1.09E+04                cpm  1111 3/28/2007 9312-10O-B0-00-45-0                14:20:00      1004 1.IOE+04      1.30E+04 cpm  1111 3/28/2007 9312-10O-SC-00-45-0                14:21:00      1004 1,05E+04                cPM  1111 3/28/2007 9312-1 0-BC-00-46-0                14:23:00      1004 1.13E+04      1.33E+04 cpm  1111 3/28/2007 931 2-1 0-SC-00-46-0                14:23:00      1004 1.05E+04                cpm  1111 3/28/2007 9312-10O-80-00-47-0                14:25:00      1004 1.05E+04      1.25E+04 cpm  1111 9312-10O-50-00-47-0    3/28/2007 14:25:00      1004 1.07E+04                cpm  1111 3/28/2007 9312-1 0-BC-00-48-0                14:28:00      1004 1.08E+04      1.27E+04 cpm  1111 3/2 8/2 007 9312-10O-SC-00-48-0                14:29:00      1004 9.91 E+03              cpm  1111 3/28/2007 9312-10-80-00-49-0                  14:36:00      1004 1.1OE+04      1.19E+04 cpm  1111 3/28/2007 7:19:00      1004 1.24E+04                cpm  1111 3/29/2007 9312-10O-80-00-50-0                14:37:00      1004 1.06E+04                cpm  1111 Page2 of 3
 
9312-0010 Scan Results 9312-1 0-SC-00-50-0    3/28/2007    14:39:00      1004 1.08E+04      1.26E+04 cpm    1111 9312-1 0-BC-00-51 -0  3/28/2007    14:40:00      1004 1.OOE+04                cpm  1111 9312-1 O-SC-00-5 1-0  .3/28/2007    14:43:00      1004 1.08E+04      1 .20E+04 cpm  1111**
9312-1 0-BC-00-52-0    3/28/2007    14:43:00      1004 1.18E+04                cpm  1111 9312-10O-SC-00-52-0    3/28/2007    14:44:00      1004 1.15E+04      1.38E+04 cpm    1111 9312-1 0-BC-00-53-O    3/28/2007    14:46:00      1004 1.02E+04                cpm  1111 9312-1 0-SC-00-53-0    3/28/2007    14:48:00      1004 1.03E+04      1.22E+04 cpm    1111 93 12-1 0-BC-00-54-0  3/28/2007    14:48:00      1004 1.02E+04                cpm  1111
ý9312-1 0--SC-00-"54-0  3/28/2007    14:52:00-    1004 1-06&G04    71.22&+04 ýCpm-  1111 9312-1 0-BC-00-55-0    3/28/007    14:53:00      1004 9.47E+03                cpm  1111 9312-1 0-SC-00-55-0    3/28/2007    14:54:00      1004 1.01 E+04    1.15E+04 cpm    1111 9312-1 0-BC-00-56-0    3/28/2007    14:55:00      1004 9.68E+03                cpm  1111 9312-1 0-SC-O0-56-0    3/28/2007    14:56:00      1004 1.02E+04    1.17E+04 cpm    1111 9312-1 0-BC-00-57-0    3/28/2007    14:57:00      1004 1.07E+04                cpm  1111
-931 2=4O-SC=00=57,tO- -3/28/200 -14:59:00--    00-4-1.08B+04- -i..28EtO-4.cpm- AiiI 9312-1 0-BC-00-58-0    3/28/2007    14:59:00      1004 9.56E+03                cpm  1111 9312-1 0-SC-00-58-0    3/28/2 007  15:01 :00      1004 9.57E+03      1.16E+04 cpm    1111 9312-1 0-BC-00-59-0    3/28/2007    15:01 :00      1004 1.03E+04                cpm  1111 9312-1 0-SC-00-59-0    3/28/2007    15:03:00      1004 1.02E+04      1.23E+04 cpm    1111 9312-1 0-BC-00-60-0    3/28/2007    15:03:00      1004 9.96E+03                cpm  1111 9312-1 0-SC-00-60-0    3/28/2007    15:05:00      1004 9.60E+03      1.20E+04 cpm    1111 9312-1 0-BC-00-61 -0  3/28/2007    15:06:00      1004 9.78E+03                cpm  1111 9312-10O-SC-00-61 -0  3/28/2007    15:07:00      1004 1.OOE+04      1.18E+04 cpm    1111 93 12-1 0-BC-00-62-0  3/28/2007    15:08:00      1004 1.01E+04                cpm  1111 9312-1 0-SC-00-62-0    3/28/20 07  15:09:00      1004 1.01IE+04    1.21 E+04 cpm  1111 9312-1 0-BC-00-63-0    3/28/2007    15:10:00      1004 1.04E+04                cpm  1111 9312-1 0-SC-00-63-0    3/28/2007    15:12:00      1004 1.07E+04      1.24E+04 cpm    1111 93 12-1 0-BC-O0-64-0  3/28/2007    15:13:00      1004 9.39E+03                cpm  1111 9312-1 0-SC-00-64-O    3/28/2007    15:14:00      1004 1.01IE+04    1.14E+04 cpm    1111 9312-1 0-BC-00-65-0    3/28/2007    15:15:00      1004 1.05E+04                cpm  1111 9312-1 0-SC-00-65-0    3/28/2007    15:17:00      1004 9.85E+03      1.25E+04 cpm    1111 9312-1 0-BC-00-66-0    3/28/2007    15:17:00      1004 9.83E+03                cpm  1111 9312-1 0-SC-00-66-0    3/28/2007    15:19:00      1004 1.08E+04      1.18E+04 cpm    1111 Page3 of 3
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)
Revision 0
 
General Narrative Page 1 of 122
 
General Narrative for Connecticut Yankee Atomic Power Co.
Work Order: 183243 SDG: MSR#07-0130 April 04, 2007 Laboratory Identification:-
GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on March 29, 2007 for analysis.
Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.
Sample Identification The laboratory received the following samples:
Laboratory        Sample Identification    Description 183243001          9312-0010-IOIF 183243002          9312-0010-102F 183243003          9312-0010-103F 183243004          9312-0010-104F 183243005          9312-0010-105F 183243006          9312-0010- 106F 183243007          9312-0010-107F 183243008          9312-0010-108F 183243009        9312-0010-109F 183243010        9312-0010-1IIOF 183243011        9312-0010-111IF 183243012        9312-0010-112F 183243013        9312-0010-1 13F 183243014        9312-0010-1 14F 183243015        9312-0010-114FS 183243016        93 12-0010-1 15F 183243017        9312-0010-1 16F 183243018        9312-0010-117F 183243019        9312-0010-1 18F 183243020        9312-0010-1 19B 183243021        9312-0010-120B 183243022        9312-0010-121B 183243023        9312-0010-122B 183243024        9312-0010-123B 183243025        9312-0010-1-017-B GEL Laboratories Phfige 2P(9f8rR71 2 Charleston, SC 29417  2040 Savge Road Charlestbn. SC 29407 P843.-556.8171 F 843.765.1178  w glcm www.gol.com
 
183243026          9312-0010-1-018-B 183243027          9312-0010-1-019-B 183243028          9312-0010-1-020-13 183243029          9312-0010-1-02 1-B 183243030          9312-0010-1-022-B 183243031          9312-0010-1-023-B 183243032          9312-0010-1-024-B 183243033          9312-001041-025-13 Items of Note There are no items to note.
Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.
Analytical Request Thirty-one soil samples were analyzed for FSSGAM and Strontium-90. Two soil samples were analyzed for FSSALL.
Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl        ýJones Project Manager GEL Laboratories Pfge 3PSftM 712    '  Chafleston, SC 29417 2040 SwagesRoad Charlast~nSC29407  P843.558.171 F8a3758.1178  www.gol.com
 
List of current GEL Certifications as of 03 April 2007 State          ]Certification Alaska          jUST-062 Arizona                          AZ0668 Arkansas                        88-065 1 CLIA                        42DO904046 California                      011 IiCA Colorado                      GenEngLabs Connecticut                      PH-01 69 Dept. of Navy                    NFESC 413 EPA                          WG-15J Florida/NELAP                        E87 156 Georgia                  E87 156 (FL/NELAP)
Hawaii                            N/A Idaho                            N/A Illinois                        200029 Indiana                        C-SC-01 Kansas                        E-10332 Kentucky                          90129 Louisiana                          03046 Maryland                            270 Massachusetts                      M-SCO1 2 Michigan                            9903 Nevada                            SC12 New Jersey                          SCO02 New Mexico                    FL NELAP E87156 New York                          11501 North Carolina                          233 North Carolina Drinking W                  45709 North Dakota                        R-158 Oklahoma                            9904 Pennsylvania                      68-00485 South Carolina            10120001/10585001/10120002 Tennessee                          02934 Texas                      TX21I3-2006A Texas NELAP                  T104704235-06-TX U.S. Dept. of Agriculture                S-52597 US Army Corps of Engineer                    N/A Utah                    8037697376 GEL Vermont                        VT87 156 Virginia                          00151 Washington                          C1641 Page 4 of 122
 
Chain of Custody and Supporting Documentation Page 5 of 122
 
Connecticut Yankee Atomic Power Company                                                          Chain of Custody Form                              No. 2007-00 100 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556        ______________                  ______________________                      ___________________                _____
I Project Name: Haddam Neck Decommissioning                                                          Analyses Requested              Lab Use Only Contact Name & Phone:                                                                                                                Comments:
Media        Sample  Container Jack McCarthy 860-267-3924                                Code          Type      Size-Analytical Lab (Name, City, State):                                    Code    &Type Code General Engineering Laboratories 2040 Savage Road Charleston, SC 29407                                                                      0 ATT: Cheryl Jones ( 843-556-817 1)
Priority: LI 30 D. [1    15 D. MI 7 D.
Other:                        _____          ____
Sample Designation                Date        Time                                                                                    Comment, Preservation 9312-0010-IOIF                3/26/07          1316      TS            G        B3P      X                          __
9312-0010-102F                3/26/07          1316      TS            G        BP              X    __                ___________
9312-0010-103F                3/26/07          1317      TS            G        BP      X                          __
9312-0010-104F                3/26/07          1320      TS            G        BP      X          __
9312-0010-105F                3/26/07          1325      TS            G        BP      X                                        _________
93 12-0010-106F              3/26/07          1325      TS            G        BP      X                          __
9312-0010-107F                3/26/07          1330      TS            G        BP      X                          __
9312-0010-108F                3/26/07          1330      TS            G        BP      X 9312-0,010-109F              3/26/07          1335      TS            G        BP      X                          __
93 12-00I10-11lOF            3/26/07          1335      TS            G        BP      X 93 12-00 10-111IF            3/26/07          1340      TS            G        BP              X  ___
NOTES: P0 #: 002332                MSR#4: 07-0130                      ZLTP QA            LI  Radwaste QA        El  Non QA        Samples Shipped Via:      Internal Container Z Fed Ex                Temp.:___
CutdSel?    Deg. C n1 UPS Hý Hand Custody Seal Intact?
LIOther YD    NE Bill of Lading #
: 5) Relinquished By                            Date/Time              66) Received eevdBBy                              aeTm Date/Time
 
Connecticut Yankee Atomic Power Company                                                              Chain of Custody Form                                          N.20-00 362 Injun Hollow Road, East Hampton, CT 06424                                                                                                              N.20-00 860-267-2556        _________          _____      ______________________                                        ________________________
Project Name: Haddam Neck Decommissioning                                                              Analyses Requested                          Lab Use Only Contact Name & Phone:                                                                                                                              Comments:
Jack McCarthy 860-267-3924                              Media    Sample    Container Code      Type        Size-Analytical Lab (Name, City, State):                                Code      &Type Code General Engineering Laboratories 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-8171)
Priority: F130D. El 15D.      ~7D.
Other:___________
Sample Designation                Date        Time                                                                                                    Comment, Preservation rj~
t.x~
93-12-0010-112F              3/26/07          1340        TS        G          BP      X                                              ____________
9312-0010-113F                3/26/07          1345        TS        G          BP      X______                                                    _________
9312-0010-114F                3/26/07          1345        TS        G          BP      X      ________                                            _________
9312-0010-114FS              3/26/07          1345        TS        G          BP      X      __                      ___________
9312-0010-115F                3/26/07          1350        TS        G          BP      X      __                      __        __    __        _________
9312-0010-116F                3/26/07          1350        TS        G          BP      X      ___          _______________
9312-0010-117F                3/26/07          1355        TS        G          BP      X      __            ____
9312-0010-118F                3/26/07          1355        TS        G          BP      X 9312-0010-119B                3/26/07          1400        TS        G          B3P      X      ______________
9312-0010-120B                3/26/07          1437        TS        G          BP      X___
9312-0010-121B                3/26/07          1438        TS      -G          BP      X      ___            __
NOTES: P0 #:002332                MSR #: 07-0130                Z LTP QA              Ej Radwaste QA                        [:1 Non QA          Samples Shipped Via:        Internal Container Z Fed Ex                  Temnp.: __ Deg. CCutdSel FI UPS Fl1 Hand
: 2) R    tved By                                        Date/Time                                            Custody Seal Intact?
: 1) tmed~~d                                        ime TiL 1  4 nI Other JIX~OqO-10/                                                              112110/C7_c1"'30 3)Relinquished By                            Date/Time            4) &/eivedBy                                          Date/Time                                                Y El  N F Bill of Lading #
: 5) Relinquished By                          Date/Time            6  eevdBBy
: 6) Received                                              aeTm Date/Time
 
Connecticut Yankee Atomic Power Company                                                                    Chain      of  Custody        Form                    N.20-00 362 Injun Hollow Road, East Hampton, CT 06424                                                                                                            N.20-00 860-267-2556                  ____        _____        _____________________                                    __________________                  _____
Project Name: H-addam Neck Decommissioning            F                                                  Analyses Requested                      Lab Use Only Contact Name & Phone:                                                                                                                              Comments:
Jack McCarthy 860-267-3924                              Media    Sample      Container Code      Type          Size-Analytical Lab (Name, City, State):                                Code          &Type General Engineering Laboratories                                                  Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-8171)
Priority:ED 30 D. E] 15 D. MI 7 D.r Sample Designation              Date        Time                                                                                                    Comment, Preservation    Lab Sample ID 9312-0010-122B                3/26/07          1439      TS        G            BP        X                  __                            __  _________
9312-0010-123B                3/26/07          1440      TS        G            BP        X                                  _______________
NOTES: P0O#      002332            MSR #: 07-130              Z    LTP QA                El  Radwaste QA                DI Non QA              Samples Shipped Via:      Internal Container Z Fed Ex                  Temp.: ___ Deg. C El UP'S
___________________________________                        [ Hand                      Custody Sealed?
1)Relinq                  ~D                    /Timne          2)    oived By                                          Date/Time                                          Custody Seal Intact?
: 3) Relinquished~y                            Date/Time          4)    c"Zeived By                                      Date/TimeBilofLading_                                  Yo    NO
: 5) Relinquished By                          Date/Time        r6) Received By                                            Date/Time
 
Connecticut Yankee Atomic Power Company                                                                    Chain of Custody FormNo207013 362 Injun Hollow Road, East Hampton, CT 06424                                                                                              N.20-00 860-267-2556                      ____      ____      ______________________                _________________________
Project Name: Haddam Neck Decommissioning                                                                  Analyses Requested      Lab Use Only Contact Name & Phone:                                                                                                              Comments:
Jack McCarthy 860-267-3924                                      Media  Sample    Container Code      Type      Size-Analytical Lab (Name, City, State):                                      Code    &Type General Engineering Laboratories                                                  Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)                                                              o Priority:DF130 D. E 15 D.ZM7D.
Other:
Sample Designation                Date            Time                                                                                  Comment, Preservation    Lab Sample ID 0n 9312-0010-1-017-B            3/22/07            1350          TS        G        BP      X___                            __
9312-0010-1-018-B3            3/22/07            1355          TS        G        BP      X      ___________
9312-0010-1-019-B            3/22/07            1400          TS        G        BP      X      __                                                      _______
9312-0010-1-020-B3            3/22/07            1405          TS        G        BP      X      __
9312-0010-1-021-B3            3/22/07            1410          TS        -G        BP      x      __
93 12-0010-4-022-B3          3/22/07            1415          TS        G        BP      x      _____
93 12-0010-1-023-B            3/22/07            1420          TS        G        BP      x_____
9312-0010-1-024-B3            3/22/07            1425          TS        G        BP      X      _______________
93 12-0010-1-025-B            3/22/07            1430          TS        G        BP      X      _____
NOTES: P0 #: 002332                MSR #: 07-013 0                        LTP QA          LI    Radwaste QA          El  Non QA Samples Shipped Via:
Z Fed Ex Intemral Container Temp.: ___ Deg, C El UPS
____________________________________                                                              F    Hand                  Custody Sealed?
: 1) Reli      edBy                                Dt/ie2)                    R  ived By                                Date/Time                              Custody Seal Intact?
3)~/                                                                                              1 ed ByOther7YL                                      N 3)Relinqui~ed B                                Date/Time            4) R    ived By                                Date/'Time                                  YO______NO___
I                                          Bill of Lading #
: 5) Relinquished By                              Date/Time            16) Received By                                  Date/Time
 
*Connecticut Yankee
  -Statement of Work for Analytical Lab Services                                            .CY-lSC-sow-ool.
Figure I. Sampie ICneck-in List DatefTime Received .          3i9C                    qý3d SDG#:                      ML                  iZ9      '0136,0)v          i.
Work Order Number:              f6'      _Zk-          ,                A  3 Shipping Cdntainer ID:    Sýe( 6&E4 5gk.-                Chain of Custody #          c,    .- PY'
: 1. Custody Seals. o6i shipping container intact?...                    .Yes    No  (
: 2.        Custody Seals dated and.signed?                                    Yes W No    [...
: 3.        Chain-of-,Custody record present?                            -      Yes    No I I
.4.        Cooler temprtr                .5=e                  .~    [Q;.
: 51.        Vermiculite/packing materials -is:    -Wet                              [1Dry  w
: 6. Number of samnples in shipping container:        7
: 7.          Sample holding times exceeded?                        .Yes              [1NoP1
    .8. Samples have.-
                      .kltapehazard                        labels
        * ..Zcutody seals                    Z    appropriate sample labels
: 9. Samples are*
                  ~ngood condition                -leaking
                -broken                            _ have air bubbles
: 10.        Were any anomnalies identified in sample receipt?'                  Yes I I NO  j 1    DDscription of anomalies. (include sample numbers):
Sample Custodian/Laborator3          AALý V,,,4-.'4                          Datm 7iZr7fjILZJ TFJ Telephoned to:
B Page 10 of 122
 
W.
w SAMPLE RECEIPT & REVIEW FORM PM use only Client:                    >1 A P%\L..                fSDG/ARCOC/Work Order:                  I  21%                      9T~4,j3Z-55 Date Received:                  3~.                      PM(A) Review (ensure non-conformana Items uare resolved prior to signing);
Received By:-________________
SampeRcitCiei                                        Comments/Qualifiers (Required for Non-Conforming Items) pie~~    ~~
CZiei Reep Shipping c niners received                        Circle Applicable: seals broken damaged container leaking container    other (describe) intact and seale                                  _________________________________
Samples requiring col                            Circle Coolant #      ice bags        blue ice        dry ice    none        other describe) 2 preservation within      (4  +-2  ?
lRecord preservation method.                        __________________________
Chain of custody documents 3 included with Shipment?                                _________________________
SSample containers intact and                        ircIe Applicable: seals broken damaged container leaking container    other (describe) sealed?________________________________
Samples requiringchmclSml                                  1'.cnanr          fitdndosvepH
    ,preservation at proper pH?
6VOA vials free of headspace.                      Samp ID' and containers affect .ed:
6(defined as <~ 6mm bubble)?.
Are Encore containers present?
7 (If yes, immediately deliver to IVOA laboratory)
Samples received. within holding                  Id's and tests affected:.
time?
9 Sample ID's on COC match ID's                        Sample ID's and containers affectel on bottles?
Sample ID's affected:
10 Date & time on COG match date
  -&    time on bottles?
Number of containers received                      Sample ID's affected:
match number indicated on COC?
12COC form is properly signed in 12relinquished/received sections?
Air Bill ,Tracking #'s, &
14Additional 147e, Comments FeS.b        7'1i5'~o1_4 Z-5iZ            t      33UZ z-'
z -7,          ~7'C,~~it Z 5-71r7&    1 SSe-if 91C"
                                              .1C      RSO RAD Receipt          #_____________
Suspcte nfomatin Hazrd    &~        ~    *If> x2 area background is observed on samples identified as "non-Su~secte Haard nfomatin          F      regulated/non-radioactive", contact the Radiation Safety group for further A l~awoloogical Ciassiticatin                        I  Maximum Counts Observed*:                2-237f' BPCB Regulated?
  -      ihppedas DOI Hazardu C Material? If yes, contact Waste                              rd Class Shipped:
Manager or ESH Manager.V D ,Regulated as a Foreign Soil?7 -
PM (or PMA) review of Hazard classification:                I/ Initials                              Date:
Page 11 of  122
 
SAMPLE RECEIPT & REVIEW FORM
      -I w
CONTINUATION FORM Client:            i4~-      Date Received: -B/z j , -  Page / -Of'/
Client:
2-oo coo Ioc Zoo am o)
Page 12 of 122
 
Data Review Qualifier Definitions Page 13 of 122
 
Data Review Qualifier Definitions Qualifier        Explanation
* A quality control analyte recovery is outside of specified acceptance criteria
              ** Analyte is a surrogate compound c        Result is less than value reported
* Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are cSX the RL A        The TIC is a suspected aldol-condensation product B        Target analyte was detected in the associated blank B        Metals-Either presence of analyte detected in the associated blank, or MDL/IDL  c sample value < PQL BD      Results are either below the MDC or tracer recovery is low C        Analyte has been confirmed by GC/MS analysis D        Results are reported from a diluted aliquot of the sample d        5-day SOD-The 2:1 depletion requirement was not met for this sample E        Organics-Concentration of the target analyte exceeds the instrument calibration range E      Metals-%difference of sample and SD is >10%.        Sample concentration must meet flagging criteria H        Analytical holding time was exceeded h        Preparation or preservation holding time was exceeded J        Value is estimated N        Metals-The Matrix spike sample recovery is not within specified control limits N        Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte    (TIC)  . Quantitation is based on nearest internal standard response factor N/A    Spike recovery limits do not apply.        Sample concentration exceeds spike concentration by 4X or more ND      Analyte concentration is not detected above the reporting limit UT      Gamma Spectroscopy-Uncertain identification x        Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y        QC Samples were not spiked with this compound Z        Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.
GEL Laboratories PIhge i4Rr1W I2      CprlscS    91      2040 Savge Road Cliailstvn.8C 29407 P843.555.171 F843.755.1178 www.gel.com
 
RADIOLOGICAL ANALYSIS Page 15 of 122
 
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 183243 Method/Analysis Information Product:                                          Aiphaspec Am241, Cm, Solid ALL FSS Analytical Method:                                DOE EML HASL-300, Am-05-RC Modified Prep Method:                                      Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:                Dry Soil Prep Analytical Batch Number:                          621107 Prep Batch Number:                                621100 Dry Soil Prep GL-RAD-A-02 1 Batch Number:          621099 Sample ID      Client ID 183243002      9312-0010-102F 183243011      9312-0010-11 IF 1201305240      Method Blank (MB) 1201305241      183245006(9312-0001 -00SF) Sample Duplicate (DUP) 1201305242    183245006(9312-0001 -00SF) Matrix Spike (MS) 1201305243      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 15.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Page 16 of 122
 
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245006 (93 12-0001-005F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Page 17 of 122
 
Product:                                          Liquid Scint Pu241, Solid-ALL FSS Analytical Method:                                DOE EML HASL-300, Pu-I 11-RC Modified Prep Method:                                      Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:                Dry Soil Prep Analytical Batch Number:                          622105 Prep Batch Number:                                621100 Dry Soil Prep GL-RAD-A-021 Batch Number:          621099 Sample ID      Client ID 183243002      9312-0010-102F 183243011      9312-0010-Il IF 1201307488      Method Blank (MB) 1201307489      183245006(9312-0001 -005F) Sample Duplicate (DUP) 1201307490      183245006(9312-0001 -00SF) Matrix Spike (MS) 1201307491      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 9.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Oualitv Control (0C0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245006 (93 12-0001-005F).
QC Information All of the QC samples met the required acceptance limits.
Page 18 of 122
 
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 183243002 (9312-0010-102F) and 183243011 (9312-00 10-11 IF)were reprepped due to low/high carrier/tracer yield.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:                                            Aiphaspec Pu, Solid-ALL FSS Analytical Method:                                  DOE EML HASL-300, Pu-IlI -RC Modified Prep Method:                                        Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:                  Dry Soil Prep Analytical Batch Number:                            622351 Prep Batch Number:                                  621100 Dry Soil Prep GL-RAD-A-021 Batch Number:            621099 Page 19 of 122
 
Sample ID      Client ID 183243002      9312-0010-1 02F 183243011      9312-0010-IIIF 1201308034      Method Blank (MB) 1201308035      183245006(9312-0001 -005F) Sample Duplicate (DUP) 1201308036      183245006(9312-0001 -005F) Matrix Spike (MS) 1201308037    Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 15.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Oualily Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245006 (9312-0001 -00SF).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples were reprepped due to low/high carrier/tracer yield.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from Page 20 of 122
 
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:                      Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:            EML HASL 300,4.5.2.3 Prep Method:                  Dry Soil Prep Analytical Batch Number:      621149 Prep Batch Number:            621101 Sample ID      Client ID 183243021      931 2-0010-120B 183243022      9312-0010-121B 183243023      9312-0010-122B 1832 43024      9312-0010-123B 183243025      9312-0010-1-017-B 183243026      9312-0010-1-018-B 183243027      9312-0010-1-019-B 183243028      9312-0010-1-020-B 183243029      9312-0010-1-021-B 183243030      9312-0010-1-022-B 183243031      9312-0010-1-023-B 183243032      9312-0010-1-024-B 183243033        9312-0010-1-025-B 1201305347      Method Blank (MB) 1201305348      183245021(9312-0001-020-1) Sample Duplicate (DUP) 1201305349      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 3 REV# 14.
Page 21 of 122
 
Calibratio~n Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245021 (93 12-0001-020-I).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prepfRe-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Page 22 of 122
 
Qualifier                  Reason                  Analyte    Sample U'          Data rejected due to low abundance. Bismuth-214 183243022 Cesium- 134 183243021 183243026 183243029 183243033 1201305348 Method/Analysis Information Product:                      Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:            EML HASL 300, 4.5.2.3 Prep Method:                  Dry Soil Prep Analytical Batch Number:      621152 Prep Batch Number:            621099 Page 23 of 122
 
Sample ID      Client ID 183243001      9312-0010-IOIF 183243002      9312-0010-102F 183243003      9312-0010-103F 183243004      9312-0010-104F 183243005      9312-0010-105F 183243006      9312-0010-106F 183243007      9312-0010-107F 183243008      9312-0010-108F 183243009      9312-0010-109F 183243010      9312-0010-1IIOF 183243011      9312-0010-111F 183243012      93 12-0010-1 12F 183243013      9312-0010-1 13F 183243014      93 12-0010-1 14F 183243015      93 12-0010-1 14FS 183243016      93 12-0010-1 1SF 183243017      93 12-0010-1 16F 183243018      93 12-0010-1 17F 183243019      93 12-0010-1 18F 183243020      9312-0010-119B 1201305354    Method Blank (MB) 1201305355      183243001(9312-0010-101 F) Sample Duplicate (DUP) 1201305356    Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Guality Control (00)Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183243001 (9312-0010-101iF).
Page 24 of 122
 
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Page 25 of 122
 
Qualifier                      Reason                        Analyte      Sample U'        Data rejected due to high counting uncertainty. Cobalt-60    183243015 U'        Data rejected due to high peak width.          Bismuth-2 12  183243005 Cesium- 137  183243007 Thallium-208  1201305354 U'        Data rejected due to interference.              Manganese-54  183243003 183243007 183243015 183243016 U1        Data rejected due to low abundance.            Bismuth-2 14  183243009 Cesium- 134  183243007 183243011 183243013 183243014 183243015 183243016 183243017 183243018 183243019 1201305355 Cobalt-60    183243002 183243003 Europiumn-152 183243016 Thallium-208  183243006 U'        Data rejected due to no valid peak.            Cobalt-60    183243014 Method/Analysis Information Page 26 of 122
 
Product:                                                    Sr90, solid-ALL FSS Product:GFPC, Analytical Method:                                  EPA 905.0 Modified Prep Method:                                      Ash Soil Prep Dry Soil Prep GL-RAD-A-02 I Method:                Dry Soil Prep Analytical Batch Number:                            621125 Prep Batch Number:                                621100 Dry Soil Prep GL-RAD-A-021 Batch Number:            621099 Sample ID      Client ID 183243001      9312-0010-IOIF 183243002      9312-0010-102F 183243003      9312-0010-103F 183243004      9312-0010-104F 183243005      9312-0010-105F 183243006      9312-0010-106F 183243007      9312-0010-107F 183243008      9312-0010-108F 183243009      9312-0010-109F 183243010      93 12-0010-1IIOF 183243011      9312-0010-IIIF 183243012      93 12-0010-1 12F 183243013      93 12-0010-1 13F 1201305281      Method Blank (MB) 1201305282      183245021(9312-0001-020-1) Sample Duplicate (DUP) 1201305283      183245021(9312-0001-020-1) Matrix Spike (MS) 1201305284      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 11.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Page 27 of 122
 
Guality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245021 (9312-0001-020-1).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 183243007 (9312-0010-107F) and 183243009 (9312-0010-109F) were recounted due to high MDAs.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformnance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Page 28 of 122
 
Product:                                                    5r90, solid-ALL FSS Product:GFPC, Analytical Method:                                EPA 905.0 Modified Prep Method:                                      Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:                Dry Soil Prep Analytical Batch Number:                          621126 Prep Batch Number:                                621102 Dry Soil Prep GL-RAD-A-02 I Batch Number:          621101 Sample ID      Client ID 183243014      93 12-0010-1 14F 183243015      9312-0010-1 14FS 183243016      93 12-0010-1 1SF 183243017      93 12-0010-1 16F 183243018      93 12-0010-1 17F 183243019      9312-0010-1 18F 183243020      93 12-0010-1 19B 183243021      93 12-0010-120B 183243022      9312-0010-12 1B 183243023      9312-0010-122B 183243024      9312-0010-123B 183243025      9312-0010-1-017-B 183243026      9312-0010-1-018-B 183243027      93 12-0010-1-01 9-B 183243028      9312-0010-1-020-B 183243029      9312-0010-1-021 -B 183243030      9312-0010-1-022-B 183243031      9312-0010-1-023-B 183243032      9312-0010-1-024-B 183243033      931 2-0010-1-025-B 1201305285      Method Blank (MB) 1201305286      183243014(9312-0010-1 14F) Sample Duplicate (DUP) 1201305287      183243014(9312-0010-1 14F) Matrix Spike (MS) 1201305288      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed inthis narrative has been analyzed in accordance with GL-RAD-A-004 REV# 11.
Calibration Information:
Calibration Information Page 29 of 122
 
All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183243014 (9312-0010-1 14F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 183243016 (9312-0010-115F), 183243025 (9312-0010-1-017-B) and 183243029 (9312-0010-1-021-13) were recounted due to a negative result greater than three times the error.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Page 30 of 122
 
Product:                      Product:Liquid Scint Tc99, Solid-ALL FSS Analytical Method:              DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number:        621139 Sample ID        Client ID 183243002        9312-0010-102F 183243011        9312-0010-1l iF 1201305310      Method Blank (MB) 1201305311      183245006(9312-0001 -005F) Sample Duplicate (DUP) 1201305312      183245006(9312-0001-005F) Matrix Spike (MS) 1201305313      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Ouality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245006 (93 12-0001-005F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Page 31 of 122
 
Sample Re-prep/Re-analysis Sample 1201305312 (9312-0001-005F) was recounted due to low/high recovery.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualif'ier information Manual qualifiers were not required.
Method/Analysis Information Product:                                          Liquid Scint Fe5S, Solid-ALL FSS Analytical Method:                                DOE RESL Fe-i, Modified Prep Method:                                      Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:                Dry Soil Prep Analytical Batch Number:                          621136 Prep Batch Number:                                621100 Dry Soil Prep GL-RAD-A-021 Batch Number:          621099 Sample ID      Client ID 183243002      9312-0010-102F 183243011      9312-0010-11 IF 1201305300      Method Blank (MB) 1201305301      183245006(9312-0001 -005F) Sample Duplicate (DUP) 1201305302      183245006(9312-0001 -00SF) Matrix Spike (MS) 1201305303      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 4.
Page 32 of 122
 
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (!OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245006 (9312-0001-005F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Page 33 of 122
 
Product:                                          Product:Liquid Scint Ni63, Solid-ALL FSS Analytical Method:                                  DOE RESL Ni-i, Modified Prep Method:                                        Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:                  Dry Soil Prep Analytical Batch Number:                            621137 Prep Batch Number:                                  621100 Dry Soil Prep GL-RAD-A-021 Batch Number:            621099 Sample ID      Client ID 183243002      9312-0010-102F 183243011      9312-0010-11IIF 1201305304      Method Blank (MB) 1201305305      183245006(9312-0001 -00SF) Sample Duplicate (DUP) 1201305306      183245006(9312-0001 -00SF) Matrix Spike (MS) 1201305307      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245006 (9312-0001 -00SF).
QC Information All of the QC samples met the required acceptance limits.
Page 34 of 122
 
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product:                      LSC, Tritium Dist, Solid - 3 pCilg Analytical Method:            EPA 906.0 Modified Analytical Batch Number:      621141 Sample ID        Client ID 183243002      9312-0010-102F 183243011      9312-0010-11 IF 1201305316      Method Blank (MB) 1201305317      183255002(931 2-0003-002F) Sample Duplicate (DUP) 1201305318      183255002(931 2-0003-002F) Matrix Spike (MS) 1201305319      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 14.
Page 35 of 122
 
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Guality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183255002 (93 12-0003-002F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Page 36 of 122
 
Product:                      Product:Liquid Scint C14, Solid AII,FSS Analytical Method:            EPA EERF C-01 Modified Analytical Batch Number:      621144 Sample ID      Client ID 183243002      9312-0010-102F 183243011      9312-0010-11 IF 1201305324      Method Blank (MB) 1201305325      183245006(9312-0001 -00SF) Sample Duplicate (DUP) 1201305326      183245006(9312-0001 -00SF) Matrix Spike (MS) 1201305327      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 9.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183245006 (93 12-0001-005F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Page 37 of 122
 
Sample Re-prep/Re-analysis Samples 1201305324 (MB),1201305325 (9312-0001 -005F), 1201305326 (9312-0001-005F) and 1201305327 (LCS) were recounted due to detector error.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.
The following data validator verified the information presented in this case narrative:
Reviewer/Date:0)                                              Il7 Page 38 of 122
 
SAMPLE DATA
 
==SUMMARY==
 
Page 39 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        - www.gel.com Certificate of Analysis Report for YANKOOlI Connecticut Yankee Atomic Power Co.
Client SDG: MSR#07-0 130 GEL Work Order: 183243 The Qualifiers in this report are defined as follows:
* A quality control analyte recovery is outside of specified acceptance criteria
  **Analyte  is a surrogate compound U    Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul  Gamma Spectroscopy--Uncertain identification ND    The analyte concentration is not detected above the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by Page 40 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                9312-0010-IOIF                  Project:        YANK01204 Sample ID:                        183243001                      Client ID:      YANKOOI Matrix:                          TS                              Vol. Recv.:
Collect Date:                    26-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        5.52%
Parameter                  Qualifier  Result  Uncertainty      LC      TPU      MDA            Units          DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                              1.13  +/-0.237  0.0753  +/-0.237    0.151          pCi/g              MJH1 04/03/07 1303 621152 Americium-241                    U -0.0022    +/-0.0988  0.0764  +/-0.0988    0.153          pCi/g Bismuth-212                              1.09  +/-0.345    0.134  +/-0.345    0.268          pCi/g Rismuth-214                              1.09  +/-0.145  0.0422  +/-0.145  0.0844          pCi/g Cesium-I134                      U    0.0454  +/-0.0666  0.0262  +/-0.0666  0.0523          pCi/g Cesium-137                              0.256  +/-0.0555  0.0227  +/-0.0555  0.0453          pCi/g Cobalt-60                        U    0.0348  +/-0.0451  0.0202  +/-0.045 1  0.0404          pCi/g Europium-152                      U    0.0544    +/-0.103    0.056  +/-0.103    0.112          pCi/g E-uropium- 154                    U    0.0802  +/-0.0857  0.0774  +/-0.0857    0.155          pCi/g Europium- 155                    U    0.0543  +/-0.0742  0.0658  +/-0.0742    0.132          pCi/g Lead-212                                  1.25    +/-0.121  0.0336  +/-0.121  0.0672          pCilg Lead-214                                  1.34  +/-0.161  0.0406  +/-0.161  0.0812          pCi/g Manganese-54                      U -0.0131    +/-0.0311  0.0223  +/-0.0311  0.0445          pCi/g Niobium-94                        U 0.00411    +/-0.0281    0.0205 +/-0.028 1  0.041          pCi/g Potassium-40                              18.0    +/-1.49    0.177    +/-1.49  0.353          pCi/g Radium-226                                1.09    +/-0.145  0.0422  +/-0.145  0.0844          pCi/g Silver-108m                      U -0.00485      +/-0.024  0.0204  +/-0.024  0.0409          pCi/g Thallium-208                            0.363  +/-0.0601    0.0204 +/-0.0601  0.0408          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90                    U -0.0197    +/-0.0136    0.015 +/-0.0136  0.0352          pCi/g              NXL3 04/03/07 1450 621125 The following Prep Methods were performed Method            Description                                          Analyst    Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBI1        03/29/07          1120    621099 The following Analytical Methods were performed Method            Description 1              EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Page 41 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-IOIF                Project:      YANKOl1204 Sample ID:                        183243001                    Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU      MDA          Units        DF Analyst Date    Time Batch 1%
Surrogate/Tracer recovery        Test                                  Recovery%      Acceptable Limits Strontium Carrier                  GFPC, SOO0, solid-ALL FSS                  85            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A    The TIC is a suspected aldol-condensation product B    For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD    Results are either below the MDC or tracer recovery is low C    Analyte has been confirmed by GCIMS analysis D    Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 42 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  -  (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-102F                  Project:      YANK01204 Sample ID:                          183243002                      Client ID: YANKOOI Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                          Client Moisture:                          .668%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU        NMA        Units        DF Analyst Date      Time Batch 1%
Rad Alpha Spec Analysis Alphaspec Am24 1, Cm, Solid ALL FSS Americium-241                    U    0.0564      +/-0.123  0.0791 +/-0.124      0.238        pCilg            GXRI 04/03/07 0933 621107 Curium-242                        U ).00852      +/-0.0646  0.0473 +/-0.0646      0.177        pCi/g Curium-2431244                    U - -0.0411    +/-0.0723  0.0834 +/-0.0724      0.246        pCi/g Aiphaspec Pu, Solid-ALL FSS Plutonium-238                    U      0.036    +1-0.101  0.0621 +/-0.101      0.218        pCi/g            GXRI 04/04/07 2258 622351 Plutonium-239I240                U - -0.0083    +/-0.0697    0.031 +/-0.0697      0.156        pCilg Liquid Scint Pu24J, Solid-ALL FSS Plutonium-241                    U      -1.5      +/-7.55      6.40    +/-7.55      13.4        pCilg            BXL1  04/05/07 1319 622105 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.854    +/-0.170  0.0628  +/-0.170    0.126        pCi/g            MIHI  04/03/07 1304 621152 Americium-241                    U    0.0524    +/-0.0784  0.0675  +/-0.0784    0.135        pCi/g Bismuth-212                            0.834    +/-0.268    0.125  +/-0.268    0.251        pCi/g Bismuth-214                              0.818    +/-0.110  0.0357  4/-0.110    0.07 13        pCi/g Cesium-134                      U    0.0381    */-0.0311  0.0221  +/-0.0311    0.0442        pCi/g Cesium-137                                1.60    +/-0.153  0.01 72  +/-0.153    0.0345        pCi/g Cobalt-60                        UI      0.00    +1-0.0282    0.025  +/-0.0282    0.050        pCi/g Europium-152                    U -0.0137      +1-0.0654  0.0533  +/-0.0654    0.107        pCi/g Europium-154                    U -0.0149      +/-0.0599  0.0494  +/-0.0599    0.0988        pCi/g Europium-ISS                      U    0.0282    +1-0.0606  0.0568  +/-0.0606    0.114        pCi/g Lead-212                                0.827    +/-0.0819  0.0294  +/-0.0819    0.0588        pCi/g Lead-214                                0.795    +/-0.107  0.0398  +/-0.107    0.0795        pCi/g Manganese-54                    U -0.00937      +/-0.0193  0.0164  +/-0.0193    0.0327        pCi/g Niobium-94                      U 0.000741      +/-0.0183  0.01 57 +/-0.0183    0.03 14        pCi/g Potassium-40                              14.3      +/-1.21    0.144    +/-1.21    0.288        pCi/g Radium-226                              0.818    +/-0.110  0.0357  4/-0.110    0.0713        pCi/g Silver-108m                      U    0.0079    */-0.0212  0.0192  +/-0.0212    0.0383        pCi/g Thallium-208                            0.238    +1-0.0495  0.01 75 +/-0.0495    0.035        pCi/g Rad Gas Flow Proportional Counting GFPC, 5r90, solid-ALL FSS Strontium-90                    U    0.0253    +/-0.0291  0.0202 +/-0.0291    0.0487        pCi/g            NXL3 04/03/07 1450 621125 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCilg Tritium                          U    -0.597        +/-1.06    0.918    +/-1.06      1.93        pCi/g            AXD2 03/31/07 1045 621141 Page 43 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171      -  www.gel.com Certificate of Analy:sis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                      Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-102F                    Project:        YANK01204 Sample ID:                          183243002                        Client ID: YANK001 Vol. Recv.:
Parameter                    Qualifier  Result    Uncertainty        LC    TPU        MDA          Units          DF Analyst Date      Time Batch 1%
Rad Liquid Scintillation Analysis Liquid Scint 0]4, Solid All, FSS Carbon-14                        U    0.0932    +/-0.0929    0.0759 +/-0.0929    0.156          pCi/g              AXD2 03/30/07 1642 621144 Liquid Scint Fe55, Solid-ALL FSS Iron-55                          U      -23        +/-35.2      25.7  +/-35.2      54.0          pCi/g              MXP1 04/02/07 2008 621136 Liquid Scint Ni63, Solid-ALL FSS Nickel-63                        U    -3.03        +/-10.1      8.62  +1-10.1      18.1          pCilg              MXPI 04/02/07 1516 621137 Liquid Scint Tc99, Solid-ALL FSS Technetium-99                    U  -0.298      +1-0.244    0.212  +1-0.244    0.434          pCilg              MXPI 04103/07 1142 621139 The following Prep Methods were performed Method            Description                                              Analyst      Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                              JMBI          03/29/07          1120    621099 The following Analytical Methods were performed Method              Description I                  DOE EML HASL-300, Am-05-RC Modified 2                  DOE EML HASL-300, Pu- Il-RC Modified 3                  DOE EML HASL-300, Pu-lII -RC Modified 4                  DOE EML HASL-300, Pu- I -RC Modified 5                  DOE EML HASL-300, Pu-lII -RC Modified 6                  DOE EML HASL-300, Pu- II -RC Modified 7                  EML HASL 300,4.5.2.3 8                  EPA 905.0 Modified 9                  EPA 906.0 Modified 10                  EPA EERF C-0 I Modified 1I                  DOE RESL Fe-I, Modified 12                  DOE RESL Ni-I, Modified 13                  DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Limits Americium-243 Tracer              Alphaspec Am241, Cm, Solid ALL              92              (15%-125%)
Plutonium-242 Tracer              Alphaspec Pu, Solid-ALL FSS                  80              (15%-125%)
Plutonium-242 Tracer              Liquid Scint Pu241, Solid-ALL F&#xfd;              92              (25%-I125%)
Strontium Carrier                  GFPC, Sr90, solid-ALL FSS                    55              (25%-I125%)
(15%-I 25%)
Page 44 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - wvww.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address :  362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                    9312-0010-102F            Project:      YANK0 1204 Sample ID:                          183243002                  Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty      LC    TPU    MDA          Units        DF Analyst Date      Time Batch A~
Ironi-59 Tracer                  Liquid Scint Fe55, Solid-ALL FS            65 Nickel Carrier                    Liquid Scint Ni63, Solid-ALL FS            79          (25%-125%)
Technetium-99m Tracer            Liquid Scint Tc99, Solid-ALL FS            78          (15%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCJMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 45 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171    -  wvww.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 tnjun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-103F                    Proiect:        YANK01204 Sample ID:                        183243003                          Client ID:      YANKO0l Matrix:                            TS                                Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          .886%
Parameter                  Qualifier    Result  Uncertainty        LC      TPU        MDA          Units        DF Analyst Date      Time Batch A%
Rad Gamma Spec Analysis Gamma,Salid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228                          0.545    +/-0.210    0.0746  +/-0.210      0.149          pCi/g            MJH1 04/03/07 1305 621152 Americium-241                  U    0.0959    +/-0.104    0.0872  +/-0.104      0.174          pCi/g Bismuth-212                            0.599    +/-0.264    0.131  +1-0.264      0.263          pCi/g Bismuth-214                            0.667    +/-0.118    0.0414  +/-0.118    0.0828          pCifg Cesium-134                      U      0.020  +/-0.0288    0.0254  +/-0.0288    0.0508          pCi/g Cesium-137                              1.91    +/-0.177    0.0222  +/-0.177    0.0444          pCi/g Cobalt-60                      UI        0.00  +/-0.0317    0.0317  +/-0.0317    0.0634          pCi/g Europium-152                    U -0.0373      +/-0.0855    0.0607  +/-0.0855      0.121          pCi/g Europium-154                    U -0.0102      +/-0.0755    0.0635  +/-0.0755      0.127          pCi/g Europium-I 55                    U    0.0766    +/-0.0969    0.0649  +/-0.0969      0.130          pCi/g Lead-21 2                              0.924    +/-0.0981    0.0334  +/-0.0981    0.0667          pCi/g Lead-214                              0.655    +/-0.124    0.0462  +/-0.124    0.0924          pCi/g Manganese-54                    UI      0.00  +/-0.0285    0.0179  +/-0.0285    0.0357          pCi/g Niobium-94                      U 0.00931      +/-0.0218    0.0191  +/-0.0218    0.0381          pCi/g Potassium-40                            16.4      +/-1.47    0.158    +/-1.47      0.316        pCi/g Radium-226                            0.667    +/-0.118    0.0414  +/-0.118    0.0828          pCi/g Silver-108m                      U 0.00333      +/-0.0243    0.0215  +/-0.0243    0.0429          pCi/g Thallium-208                            0.364  +/-0.0635    0.0205  +/-0.0635      0.041        pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90                    U    0.0254    +/-0.0292    0.0206 +/-0.0292        0.049        pCi/g            NXL3 04/03/07 1450 621125 The following Prep Methods were performed Method            Description                                            Analyst        Date            Time    Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                              1MB 1          03/29/07          1120    621099 The following Analytical Methods were performed Method            Description 1                  EML HASL 300,4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%            Acceptable Limits Page 46 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - wvww.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address :    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-103F                Project:      YANK01204 Sample ID:                        183243003                    Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU        MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                55            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD1 Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected
* Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +1-RE. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 47 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Anallsis Company :    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-104F                  Project:        YANK01 204 Sample ID:                        183243004                      Client ID:      YANKOO 1 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          9.14%
Parameter                    Qualifier    Result  Uncertainty      LC    TPU        MDA          units          DF Analyst Date        Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.440    +/-0.152  0.0514  +1-0.152    0.103          pCi/g              MJIi 04/03/07 1306 621152 Americium-241                      U    0.0491    +/-0.0632    0.0534 +/-0.0632    0.107          pCi/g Bismuth-212                              0.340    +/-0.231    0.143  +/-0.231    0.285          pCi/g Bismuth-214                              0.333  +1-0.0811    0.031 +/-0.0811  0.0619          pCi/g Cesium-134                        U 0.00984      +/-0.0251    0.0211 +/-0.0251  0.0421          pCi/g Cesium-137                                0.144  +/-0.0383    0.0195 +/-0.0383    0.039          pCi/g Cobalt-60                        U 0.00809      +/-0.0206    0.018 +/-0.0206    0.036          pCi/g Europium-152                      U -0.0162      +/-0.0635    0.0482 +/-0.0635  0.0963          pCi/g Europium-154                      U    0.0103    +/-0.0521    0.0449 +/-0.0521  0.0897          pCi/g Europium-155                      U -0.00511    +/-0.0593    0.0494 +/-0.0593  0.0987          pCi/g Lead-212                                0.607  +/-0.0738    0.0281 +/-0.0738  0.0562          pCi/g Lead-214                                0.411  +/-0.0962    0.0362 +/-0.0962  0.0723          pCi/g Manganese-54                      U 0.00815      +/-0.0213    0.019 +/-0.0213    0.038          pCi/g Niobium-94                        U 0.00626      +/-0.0193    0.0166 +/-0.0193  0.0333          pCi/g Potassium-40                              10.2  +/-0.983    0.142  +/-0.983    0.285          pCi/g Radium-226                              0.333  +/-0.0811    0.031 +/-0.0811  0.0619          pCi/g Silver-I 08m                      U -0.01 86    +/-0.0216    0.0169 +/-0.0216  0.0338          pCi/g ThAlium-208                              0.207  +/-0.0483    0.0162 +/-0.0483  0.0323          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, so/id-ALL ESS Strontium-90                      U      0.037  +/-0.0299    0.0231 +/-0.0299  0.0491          pCi/g              NXL3    04/03/07 1450 621125 The following Prep Methods were performed Method              Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            IMBI        03/29/07          1120    621099 The following Analytical Methods were performed Method              Description I                    EML HASL 300, 4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Limits Page 48 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-104F              Project:      YANK01204 Sample ID:                          183243004                  Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU      NMA        units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                  Recovery%      Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                69          (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 49 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.comn Certificate of Analysis Company:    Connecticut Yankee Atomiic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-105F                  Proiect:        YANK01204 Sample ID:                          183243005                      Client ID: YANK001 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                          Client Moisture:                          2.35%
Parameter(                    )ualifier    Result  Uncertainty      LC      TPU      MDA          units          DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                              0.674    +/-0.2 15  0.0773  +/-0.2 15  0.155          pCi/g              MJH1 04/03/07 1418 621152 Americium-241                    U - 0.00664    +/-0.0423  0.0346  +/-0.0423  0.0691          pCi/g Bismuth-212                      UI      0.00    +1-0.266    0.166  +/-0.266    0.331          pCi/g Bismuth-2 14                            0.435    +/-0.119  0.0454  +/-0.119  0.0907          pCi/g Cesium- 134                      U      0.033  +/-0.0334  0.0317  +/-0.0334  0.0633          pCi/g Cesium-l 37                              0.087  +/-0.0343  0.0226  +/-0.0343  0.045 3        pCi/g Cobalt-60                        U - 0.005 15  +/-0.0266  0.02 16 +/-0.0266  0.0431          pCi/g Europium-152                      U    0.0985    +/-0.0821  0.0677  +/-0.0821    0.135          pCi/g Europium-154                      U -0.0906      +/-0.0954  0.0696  +/-0.0954    0.139          pCi/g Europium-155                      U -0.0211      +/-0.0656  0.0588  +/-0.0656    0.118          pCi/g Lead-21 2                                0.585  +/-0.0958  0.0344  +/-0.0958  0.0687          pCi/g Lead-214                                0.593    +/-0.118  0.0396  +/-0.118  0.0792          pCi/g Manganese-54                      U    0.0246    +/-0.0295  0.0276  +/-0,0295  0.0552          pCi/g Niobium-94                        U    0.0116    +/-0.028  0.0246    +/-0.028  0.0492          pCi/g Potassium-40                              11.5    +1-1.26    0.229    +/-1.26  0.457          pCi/g Radium-226                              0.435    +/-0.119  0.0454  +/-0.119  0.0907          pCi/g Silver-108m                      U - 0.00602    +/-0.0233  0.0201  +/-0.0233  0.0401          pCi/g Thallium-208                            0.222  +/-0.0567  0.0257  +/-0.0567  0.0514          pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90                      U -0.0105      +/-0.0178  0.0168 +/-0.0 178  0.0401          pCi/g              NXL3 04/03/07 1450 621125 The following Prep Methods were performed Method              Description                                            Analyst    Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                              JMB1        03/29/07          1120    621099 The following Analytical Methods were performed Method            Description 1                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%        Acceptable Limits Page 50 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-105F                Project:      YANK01204 Sample ID:                          183243005                    Client ID: YANKO0 I Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU        MBA        Units        DF Analyst Date      Time Batch A Surrogate/Tracer recovery      Test                                  Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                79            (25%-1 25%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 51 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171    -  www.gel.com Certificate of Analy:sis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                      Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-106F                    Project:        YANK01204 Sample ID:                        183243006                        Client ID:      YANK001 Matrix:                            TS                                Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          8.58%
Parameter                  Qualifier  Result  Uncertainty        LC      TPU        MDA          Units          DF Analyst Date      Time Batch A~
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            0.587    +1-0.174  0.0561    +/-0.174      0.112          pCi/g              MJH1 04/03/07 1419 621152 Americium-241                    U  -0.054    +/-0.0925    0.0714  +/-0.0925      0.143          pCi/g Bismuth-212                            0.416    +/-0.212    0.121  +/-0.212      0.241          pCi/g Bismuth-214                            0.404  +1-0.0884    0.0303  +/-0.0884    0.0605          pCilg Cesium-I 34                      U    0.0383    +/-0.0373  0.0203  +/-0.0373    0.0405          pCilg Cesium-137                        U    0.0288    +/-0.0251  0.0178  +/-0.0251    0.0356          pCilg Cobalt-60                        U    0.0174    +/-0.0236  0.0164  +/-0.0236    0.0328          pCi/g Europium-152                      U    0.0111    +/-0.0674  0.0482  +/-0.0674    0.0963          pCi/g Europium-I 54                    U    0.0379    +/-0.0591  0.0542  +/-0.0591      0.108          pCi/g Europium-ISS                      U    0.0229    +/-0.0547  0.0519  +/-0.0547      0.104          pCi/g Lead-212                                0.497  +/-0.0646  0.0268  +/-0.0646    0.0536          pCi/g Lead-214                                0.483    +/-0.104  0.0323    +/-0.104    0.0645          pCi/g Manganese-54                    U    0.0137    +/-0.0191  0.0173  +/-0.0191    0.0346          pCi/g Niobium-94                      U 0.00727      +/-0.017  0.01 52  +/-0.017    0.0305          pCi/g Potassium-40                            10.7      +/-1.06    0.161    +/-1.06    0.321          pCi/g Radium-226                              0.404  +/-0.0884  0.0303  +/-0.0884    0.0605          pCi/g Silver-108m                      U -0.00899    +/-0.0188  0.0154  +/-0.0188    0.0308          pCi/g Thallium-208                    UI      0.00  +/-0.0409  0.0324  +/-0.0409    0.0648          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U -0.0223      +/-0.0227    0.02 14 +/-0.0227    0.0475          pCi/g              NXL3 04/03/07 1450 621125 The following Prep Methods were performed Method            Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                              JMB1          03/29/07          1120    621099 The following Analytical Methods were performed Method              Description 1                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Limiits Page 52 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-106F              Project:      YANK01204 Sample ID:                        183243006                    Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                82            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit
* Sample results are rejected
* Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 53 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171    - www.gel~com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address :    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-107F                    Project:      YANK01204 Sample ID:                        183243007                        Client ID: YANKO0l Matrix:                            TS                                Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          5.37%
Parameter                    Qualifier    Result  Uncertainty      LC      TPU        MDA          Units          DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                              1.14    +1-0.304    0.096  +/-0.304      0.192          pCi/g            MJHl 04/03/07 1420 621152 Americium-241                    U      0.024  +/-0.0594    0.0503  +1-0.0594      0.101          pCilg Bismuth-212                            0.894    +1-0.519    0.228  +1-0.519      0.455          pCi/g Bismuth-214                            0.677    +/-0.141  0.0568  +/-0.141      0.113          pCi/g Cesium-134                      UI      0.00  +1-0.0507    0.0409  +1-0.0507    0.0817          pCilg Cesium-137                      UI      0.00    +/-0.103  0.0304  +/-0.103    0.0608          pCi/g Cobalt-60                        U -0.00939    +/-0.0363    0.0296  +/-0.0363    0.0591          pCi/g Europium-152                      U -0.0441      +/-0.104  0.0741  +/-0.104      0.148          pCi/g Europium-154                      U    0.0534    +/-0.129    0.099  +/-0.129      0.198          pCilg Europium-ISS                      U    0.0566    +/-0.107  0.0742  +/-0.107      0.148          pCi/g Lead-212                                0.990    +/-0.123    0.044  +/-0.123      0.088          pCi/g Lead-214                                0.706    +/-0.134  0.0552  +/-0.134      0.110          pCi/g Manganese-54                    UI      0.00  +/-0.0443    0.0295  +1-0.0443      0.059          pCilg Niobium-94                        U    0.01 75  +/-0.0363  0.03 19 +/-0.0363    0.0637          pCi/g Potassium-40                              15.8      +/-1.67  0.268    +/-1.67    0.535          pCi/g Radium-226                              0.677    +/-0.141  0.0568  +/-0.141      0.113          pCi/g Silver-108m                      U -0.00602    +/-0.0321  0.0281  +/-0.0321    0.0561          pCi/g Thallium-208                            0.333    +/-0.0748  0.0311  +/-0.0748    0.0623          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                      U -0.0155      +/-0.016  0.0165  +/-0.016    0.0395          pCi/g            NXL3 04/04/07 1202 621125 The following Prep Methods were performed Method              Description                                            Analyst      Date            Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            IMBI          03/29/07          1120    621099 The following Analytical Methods were performed Method              Description 1                    EML HASL 300,4.5.2.3 2                  EPA 905.0 Modified 3                  EPA 905.0 Modified Page 54 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-107F              Project:      YANK01204 Sample ID:                        183243007                  Client ID: YANKOOlI Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    [C    TPU      XMA        units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%      Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL F55                64            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCJMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 55 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel .com Certificate of Analysis Company :    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-108F                  Project:        YANKO 1204 Sample ID:                        183243008                      Client ID:      YANKOO 1 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          4.07%
Parameter                  Qualifier    Result  Uncertainty        LC    TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            0.574    +/-0.180  0.0891  +/-0.180    0.178          pCi/g            MIHI 04/03/07 1421 621152 Americium-241                    U    0.0246  +/-0.0383    0.034  +/-0.0383  0.0679          pCi/g Bismuth-212                      U    0.370    +/-0.275    0.203  +/-0.275    0.405          pCilg Bismuth-214                            0.441    +/-0.104  0.0377  +/-0.104  0.0754          pCi/g Cesium-134                        U    0.0366  +/-0.0308    0.0302  +/-0.0308  0.0604          pCi/g Cesium-137                        U    0.0418  +/-0.0429    0.0247  +/-0.0429  0,0494          pCi/g Cobalt-60                        U    0.0213    +/-0.0279  0.0262  +/-0.0279  0.0523          pCi/g Europium-152                      U    0.0665    +/-0.0646    0.061 +/-0.0646    0.122          pCi/g Europium-154                      U      0.018  +/-0.0994  0.0849  +/-0.0994    0.170          pCi/g Europium-155                      U    0.0401    +/-0.0569  0.0546  +/-0.0569    0.109          pCi/g Lead-21 2                                0.553  +/-0.0805  0.0288  +/-0.0805  0.0575          pCi/g Lead-214                                0.429  +/-0.0981  0.0356  +/-0.0981  0.0711          pCi/g Manganese-54                      U    -0.019    +/-0.030  0.0238  +/-0.030  0.0476          pCi/g Niobium-94                        U 0.000509      +/-0.026    0.022  +/-0.026  0.0439          pCi/g Potassium-40                              9.10      +/-1.15    0.202    +/-1.15  0.403          pCi/g Radium-226                              0.441    +/-0.104  0.0377  +/-0.104  0.0754          pCi/g Silver-108m                      U -0.00662      +/-0.023  0.0198  +/-0.023  0.0397          pCi/g Thallium-208                            0.191  +/-0.0511  0.0215  +/-0.0511    0.043        pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                      U 0.008 14    +/-0.0206  0.0158 +/-0.0206    0.0384          pCi/g              NXL3 04/03/07 1601 621125 The following Prep Methods were performed Method            Description                                            Analyst      Date            Time    Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JM[B1        03/29/07        1120    621099 The following Analytical Methods were performed Method              Description 1                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery %        Acceptable Limits Page 56 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils P04* 002332 Client Sample ID:                  9312-0010-108F              Project:      YANK01204 Sample ID:                          183243008                  Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU    NMA          units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                  Recovery%      Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                72          (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCJMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit
* Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD, of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 57 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                9312-0010-109F                  Project:        YANK0 1204 Sample ID:                        183243009                      Client ID: YANKOOI Matrix:                          TS                              Vol. Recv.:
Collect Date:                    26-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        2.7 1%
Parameter                  Qualifier    Result  Uncertainty      LC    TPU        MDA          Units          DF Analyst Date        Time Batch A~
Rad Ganmma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-~228                            1.21  +/-0.278    0.110  +/-0.278    0.220          pCi/g              MJHI 04/03/07 1422 621152 Americium-241                    U    0.0266  +1-0.0564  0.0458  +1-0.0564  0.0916          pCi/g Bismuth-212                            0.940    +/-0.498    0.261  +/-0.498    0.522          pCi/g Bismuth-214                    UI        0.00  +/-0.202    0.144  +/-0.202    0.288          pCi/g Cesium-134                      U    0.0604  +/-0.0458    0.044 +1-0.0458  0.0879          pCi/g Cesium-137                              0.276    +/-0.074  0.0352  +/-0.074  0.0704          pCilg Cobalt-60                        U    0.0292  +/-0.0413  0.0382  +/-0.0413  0.0764          pCi/g Europium-152                    U    -0.026    +/-0.114  0.0736  +/-0.114    0.147          pCi/g Europium-154                    U    0.0784    +/-0.164    0.127  +/-0.164    0.254          pCi/g Europium-iSS                    U      0.031  +/-0.0799    0.0718 +/-0.0799    0.144          pCi/g Lead-212                                1.04    +/-0.129  0.0419  +/-0.129  0.0837          pCi/g Lead-214                                1.11    +1-0.169  0.0551  +/-0.169    0.110          pCilg Manganese-54                    U    -0.012  +/-0.0457    0.0328 +/-0.0457  0.0656          pCilg Niobium-94                      U    0.0293  +/-0.0334    0.0314 +/-0.0334  0.0627          pCi/g Potassium-40                            17.4    +1-1.61    0.266  +/-1.61    0.531        pCi/g Radium-226                              1.05    +/-0.202  0.0552  +/-0.202    0.110          pCilg Silver-108m                    U -0.0154      +/-0.0304    0.0253 +/-0.0304  0.0506          pCifg Thallium-208                          0.451  +/-0.0853    0.0307 +/-0.0853  0.0613          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U    0.0191  +/-0.0259    0.0188 +/-0.0259  0.0445          pCi/g              NXL3 04/04/07 1202 621125 The following Prep Methods were performed Method            Description                                          Analyst      Date            Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            1MB]        03/29/07          1120    621099 The following Analytical Methods were performed Method            Description 1                  EML HASL 300,4.5.2.3 2                  EPA 905.0 Modified 3                  EPA 905.0 Modified Page 58 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-109F                Project:      YANK01204 Sample ID:                        183243009                    Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU        MDA        Units        DF Analyst Date      Time Batch A~
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, SrOO, solid-ALL FSS                57            (25%-I125%)
Notes:
The Qualifiers in this report are defined as follows:
I** Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
B3D Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 59 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  -  (843) 556-8171    -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                9312-0010-1IIOF                  Project:        YANKO 1204 Sample ID:                        183243010                        Client ID: YANKOG 1 Matrix:                          TS                              Vol. Recv.:
Collect Date:                    26-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        10.9%
Parameter                    Qualifier  Result  Uncertainty      LC    TPU        MDA          Units          DF Analyst Date        Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                          0.864    +/-0.207  0.0632  +/-0.207      0.126          pCi/g              MIHI 04/03/07 1458 621152 Americium-241                    U 0.000144      +/-0.117  0.0926  +1-0.117      0.185          pCi/g f3ismuth-212                          0.695    +/-0.286  0.141  +/-0.286      0.281          pCi/g l3ismuth-214                          0.732    +/-0.122  0.0399  +/-0.122    0.0797          pCi/g Cesium-134                      U    0.0303  +/-0.0269    0.025 +/-0.0269    0.0499          pCi/g Cesium-137                            0.430  +/-0.0566  0.0181 +/-0.0566    0.0362          pCi/g Cobalt-60                        U    0.0163  +/-0.0265  0.0236 +/-0.0265    0.0471          pCi/g Europium-152                    U    0.018    +/-0.107  0.0549  +/-0.107      0.110          pCi/g Europium-154                    U -0.0424    +/-0.0687  0.0558 +/-0.0687      0.112          pCi/g Europium-155                    U    0.0121  +/-0.0948  0.0615 +/-0.0948      0.123          pCi/g Lead-212                              0.807  +/-0.0967  0.0319 +/-0.0967    0.0637          pCi/g Lead-214                              0.841    +/-0.129  0.0372  +/-0.129    0.0744          pCi/g Manganese-54                    U -0.0134    +/-0.0264  0.0184 +/-0.0264    0.0368          pCi/g Niobium-94                      U    0.0144  +/-0.0224  0.0203 +/-0.0224    0.0406          pCi/g Potassium-40                            9.69    +/-0.999  0.152  +/-0.999      0.303          pCi/g Radium-226                            0.732    +/-0.122  0.0399  +/-0.122    0.0797          pCi/g Silver-108m                      U -0.00301    +/-0.0224  0.0192 +/-0.0224    0.0385          pCi/g Thallium-208                          0.287    +/-0.0563  0.0197 +/-0.0563    0.0393          pCi/g Rad Gas Flow Proportional Counting CJFPC, Sr9O, so/id-ALL ESS Strontium-90                    U -0.0105      +/-0.0185  0.0176 +/-0.0185    0.0425          pCi/g              NXL3 04/03/07 1602 621125 The following Prep Methods were performed Method              Description                                          Analyst      Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                          IMBI          03/29/07          1120    621099 The following Analytical Methods were performed Method            Description I                    EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                Recovery%          Acceptable Limits Page 60 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  93 12-0010-1IIOF            Project:      YANK01204 Sample ID:                          183243010                  Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty      LC    TPU    MDA        Units        DF Analyst Date      Time Batch A Surrogate/Tracer recovery        Test                                  Recovery%    Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  67          (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 61 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - wvww.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-11IIF              Project:      YANKOI1204 Sample ID:                          183243011                    Client ID:    yANKOOlI Matrix:                            TS                            Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                          Client Moisture:                          4.44%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU      MDA        Units        DF Analyst Date      Time Batch 1%
Rad Alpha Spec Analysis Aiphaspec Am24], Cm, Solid ALL FSS Americium-241                    U    0.0126    +/-0.146    0.117  +/-0.146  0.337        pCi/g            GXR1 04/03/07 0933 621107 Curium-242                        U - -0.0375      +/-0.085  0.0702    +/-0.085  0.246        pCi/g Curium-243/244                    U- -0.0136      +/-0.144    0.127  +/-0.144  0.356        pCi/g Aiphaspec Pu, Solid-ALL FSS Plutonium-238                    U    0.0746    +/-0.148    0.091 +/-0.149    0.279        pCi/g            GXRI 04/04/07 2258 622351 Plutonium-239/240                U -( 0.00717    +/-0.0798    0.072 +/-0.0798    0.241        pCi/g Liquid Scint Pu24J1, Solid-ALL FSS Plutonium-241                    U      -3.35      +/-7.83      6.73  +/-7.83    14.1      pCi/g            BXL1  04/05/07 1335 622105 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                              0.729    +/-0.197    0.0626  +/-0.197  0.125        pCi/g            MJH1 04/03/07 1513 621152 Americium-241                    U      0.073    &#xf7;1-0. 109  0.0823  +/-0.109  0.165        pCi/g Bismuth-212                              0.337    +/-0.232    0.139  +/-0.232  0.278        pCi/g Bismuth-214                              0.488  +/-0.0902    0.0335  +/-0.0902  0.0669        pCi/g Cesium-134                      UI        0.00  +1-0.0371    0.0237  +/-0.03 71 0.0474        pCi/g Cesium-137                        U    0.0191    +/-0.0239  0.0215  +/-0.0239  0.0429        pCi/g Cobalt-60                        U -0.00555      +/-0.0231    0.019  +/-0.0231  0.0381        pCi/g Europium-152                      U    0.0446    +/-0.0894    0.0484  +/-0.0894  0.0967        pCi/g Europium-154                      U -0.0162      +/-0.0721    0.0601  +/-0.0721  0.120        pCi/g Europium-iSS                      U    0.0198    +/-0.0598    0.0554  +/-0.0598  0.111        pCi/g Lead-212                                  0.636  +/-0.0765    0.0278  +/-0.0765  0.0556        pCi/g Lead-214                                  0.513    +/-0.099    0.0337  +/-0.099  0.0674        pCi/g Manganese-54                      U 0.00587      +/-0.0236    0.0208  +/-0.0236  0.0416        pCi/g Niobium-94                        U 0.00202      +/-0.0198    0.0176  +/-0.0198  0.0351        pCi/g Potassium-40                                10.4    +/-1.18    0.173    +/-1.18  0.346        pCi/g Radium-226                                0.488  +/-0.0902    0.0335  +/-0.0902  0.0669        pCi/g Silver-108m                      U -0.0155      +/-0.0179    0.0151  +/-0.0179  0.0303        pCi/g Thallium-208                              0.221  +/-0.0446    0.0181  +/-0.0446  0.0361        pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                      U    0.0024    +/-0.0217    0.0178 +/-0.0217  0.0417        pCi/g            NXL3 04/03/07 1641 621125 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium                          U    -. 2
                                          -0.325      +/-1.07    0.916    +/-1.07    1.92      pCi/g            AXD2 03/31/07 1146 621141 Page 62 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com C~trtifivnh-.nf Anniv.d.~c Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                    93 12-0010-11IIF              Proiect:        YANK01 204 Sample ID:                          183243011                    Client ID: YANK00 I Vol. Recv.:
Parameter                    Qualifier    Result  Uncertainty        LC    TPU    MDA          Units          DF Analyst Date      Time Batch 1%
Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All, FSS Carbon-14                        U -0.00732      +/-0.0887    0.0746 +1-0.0887  0.153          pCi/g              AXD2 03/30/07 1744 621144 Liquid Scint FeSS, Solid-ALL FSS Iron-55                          U    -2.17        +/-30.8      22.0  +/-30.8  46.2          pCi/g              MXPI 04/02/07 2024 621136 Liquid Scint Ni63, Solid-ALL FSS Nickel-63                        U    -1.61        +/-10.0      8.49  +/-10.0  17.8          pCi/g              MXPI 04/02/07 1532 621137 Liquid Scint Tc99, Solid-ALL FSS Technetium-99                    U      -0.20      +/-0.237    0.203  +/-0.237  0.416          pCi/g              MXPI 04/03/07 1214 621139 The following Prep Methods were performed Method              Description                                            Analyst    Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                              IMBI      03/29/07          1120    621099 The following Analytical Methods were performed Method              Description 1                    DOE EML HASL-300, Am-05-RC Modified 2                    DOE EML HASL-300, Pu- I I -RC Modified 3                    DOE EML HASL-300, Pu- I I1-RC Modified 4                    DOE EML HASL-300, Pu- I Il-RC Modified s                    DOE EML HASL-300, Pu-I I-RC Modified 6                    EML HASL 300, 4.5.2.3 7                    EPA 905.0 Modified 8                    EPA 906.0 Modified 9                    EPA EERF C-01 Modified 10                    DOE RESL Fe-I, Modified I1I                  DOE RESL Ni-l, Modified 12                    DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery        Test                                    Recovery%      Acceptable Limits Americium-243 Tracer                Alphaspec Am24l, Cm, Solid ALL                77          (15%-125%)
Plutonium-242 Tracer                Alphaspec Pu, Solid-ALL FSS                    85          (15%-I125%)
Plutonium-242 Tracer                Liquid Scint Pu241, Solid-ALL FS              86          (25%-125%)
Strontium Carrier                  GFPC, Sr90, solid-ALL FSS                      66          (25%-125%)
Iron-59 Tracer                      Liquid Scint Fe55, Solid-ALL FS                66          (15%-125%)
Nickel Carrier                      Liquid Scint Ni63, Solid-ALL FS                79          (25%-I125%)
Page 63 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO#t 002332 Client Sample ID:                    9312-0010-IIIF            Project:      YANK01204 Sample ID:                          183243011                  Client ID: YANKOCI Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty      LC    TPU    MDA          Units        DF Analyst Date      Time Batch A Technetium-99m Tracer            Liquid Scint Tc99, Solid-ALL FS            82          (15%-I125%)
Notes:
The Qualifiers in this report are defined as follows:
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCJMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UT Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 64 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  93 12-0010-1 12F                Project:        YANK01204 Sample ID:                        183243012                        Client ID:      YANKOQI Matrix:                            TS                              Vol. Reev.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          8.25%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU      MDA          Units          DF Analyst Date        Time Batch A' Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                              1.18    +/-0.251  0.0665  +/-0.251    0.133          pCi/g              MJH1 04/03/07 1514 621152 Americium-241                    U    0.0532    +/-0.109    0.094  +/-0.109    0.188          pCi/g Bismuth-212                            0.538    +/-0.332    0.152  +/-0.332    0.304          pCi/g Bismuth-214                            0.620    +/-0.105  0.0362  +/-0.105  0.0723          pCi/g Cesium- 134                      U    0.0519    +/-0.0429  0.0268  +1-0.0429  0.0535          pCi/g Cesium-137                        U -0.0235      +/-0.0239  0.0193  +/-0.0239  0.0386          pCi/g Cobalt-60                        U -0.0023      +/-0.0305  0.0219  +/-0.0305  0.0438          pCilg Europium-152                      U -0.0438      +/-0.0689  0.0537  +/-0.0689    0.107          pCi/g Europium-154                      U -0.0443      +/-0.0793  0.0637  +/-0.0793    0.127          pCi/g Europium-155                      U    0.0459    +/-0.093  0.0632  +/-0.093    0.126          pCi/g Lead-212                                0.921    +/-0.0971  0.0305  +/-0.0971    0.061          pCi/g Lead-214                                0.665    +/-0.120  0.0388  +/-0.120  0.0776          pCi/g Manganese-54                      U 0.00571      +/-0.025  0.0217  +/-0.025  0.0434          pCi/g Niobium-94                        U -0.00695    +/-0.0224  0.0191  +/-0.0224  0.0381          pCi/g Potassium-40                              16.2      +/-1.53    0.163    +/-1.53    0.325          pCi/g Radium-226                              0.620    +/-0.105  0.0362  +/-0.105  0.0723          pCi/g Silver-108m                      U 0.00705      +/-0.0211  0.0186  +/-0.0211  0.0372          pCi/g Thallium-208                            0.320    +/-0.0523  0.0193  +/-0.0523  0.0387          pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90                    U    0.0105    +/-0.0257  0.0201 +/-0.0257    0.0465          pCi/g              NXL3 04/03/07 1641 621125 The following Prep Methods were performed Method            Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBI        03/29/07          1120    621099 The following Analytical Methods were performed Method              Description I              EML HASL 300,4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Limits Page 65 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address :    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-1 12F              Project:      YANK01204 Sample ID:                        183243012                    Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC      TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  57            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 66 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-1 13F                  Project:        YANK01 204 Sample ID:                          183243013                        Client ID: YANKOG 1 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                        29-MAR-07 Collector:                          Client Moisture:                          2.4%
Parameter                  Qualifier  Result  Uncertainty        LC      TPU      MDA          units          DF Analyst Date        Time Batch A~
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                          0.989    +/-0.213    0.0792  +/-0.213    0.158          pCi/g              MJH1 04/03/07 1529 621152 Americium-241                    U    0.0362    +/-0.0392    0.0346  +/-0.0392  0.0691          pCilg Bismuth-212                            0.622    +/-0.294    0.157  +/-0.294    0.314          pCilg Bismuth-214                            0.682    +/-0.115    0.0403  +/-0.115  0.0805          pCilg Cesium-134                      UI      0.00  +1-0.0504    0.0303  +/-0.0504  0.0606          pCi/g Cesium-137                            0.0626    +/-0.0304    0.0234  +/-0.0304  0.0468          pCi/g Cobalt-60                        U -0.0172      +/-0.028    0.0217  +/-0.028  0.0434          pCi/g Europium-1 52                    U -0.00738    +/-0.0872    0.0538  +/-0.0872    0.108          pCi/g Europium-154                    U -0.0346      +/-0.0918    0.0706  +/-0.0918    0.141          pCi/g Europium-ISS                    U    0.0479    +/-0.0683    0.0544  +/-0.0683    0.109          pCi/g Lead-212                              0.845    +/-0.109    0.0317  +/-0.109  0.0633          pCi/g Lead-214                              0.719    +/-0.118    0.0378  +/-0.118  0.0755          pCi/g Manganese-54                      U    0.0115    +/-0.0261    0.0239  +/-0.0261  0.0477          pCi/g Niobium-94                      U -0.0092      +/-0.0231    0.0191  +/-0.0231  0.0382          pCi/g Potassium-40                            17.0      +/-1.51    0.151    +/-1.51    0.302          pCi/g Radium-226                            0.682    +1-0.115    0.0403  +/-0.115  0.0805          pCi/g Silver-108m                      U -0.00232    +/-0.0208    0.0185  +/-0.0208    0.037          pCi/g Thallium-208                          0.281    +/-0.0536    0.0225  +/-0.0536    0.045          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U -0.0163      +/-0.0207      0.019 +/-0.0207  0.0419          pCi/g              NXL3 04/03/07 1641 621125 The following Prep Methods were performed Method              Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                              JMBI        03/29/07          1120    621099 The following Analytical Methods were performed Method            Description I                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Linits Page 67 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  93 12-0010-1 13F            Project:      YANK01204 Sample ID:                        183243013                  Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU      MDA        Units        DF Analyst Date      Time Batch A~
Surrogate/Tracer recovery        Test                                  Recovery%      Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  64          (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 68 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address :362      Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-114F                  Project:      YANKO 1204 Sample ID:                        183243014                      Client ID: YANKOO I Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          4.58%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU      MDA          Units        DF Analyst Date      Time Batch A%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.841    +/-0.151  0.0398  +/-0.151  0.0796          pCi/g            MIHI    04/03/07 1912 621152 Americium-241                    U    0.0652    +/-0.0679  0.0557  +/-0.0679    0.111          pCi/g Bismuth-212                            0.516    +/-0.170  0.0838  +/-0.170    0.168          pCi/g Bismuth-214                            0.769  +/-0.0931    0.0225  +/-0.0931  0.0449          pCilg Cesium-134                      UI      0.00  +/-0.0224  0.0149  +/-0.0224  0.0297          pCi/g Cesium-137                              0.496    +/-0.05 12  0.0115  +1-0.05 12  0.0229          pCi/g Cobalt-60                        UI      0.00  +/-0.0243  0.0126  +/-0.0243  0.0252          pCi/g Europium-152                    U -0.0279      +/-0.0488  0.0313  +/-0.0488  0.0626          pCi/g Europium-154                    U    0.0176    +/-0.0478  0.0354  +/-0.0478  0.0708          pCi/g Europium-ISS                    U    0.0448    +/-0.0628  0.0371  +/-0.0628  0.0742          pCi/g L~ead-212                              0.829    +/-0.0798  0.0187  +/-0.0798  0.0374          pCi/g Lead-214                              0.788    +/-0.0897  0.0225  +/-0.0897  0.0451          pCi/g Manganese-54                    U 0.00481      +/-0.0157  0.0119  +/-0.0157  0.0239          pCi/g Niobium-94                      U -0.0118      +/-0.0121  0.0101  +/-0.0121  0.0203          pCi/g Potassium-40                            10.6    +/-0.809  0.0885  +/-0.809    0.177          pCi/g Radium-226                            0.769    +/-0.0931  0.0225  +/-0.0931  0.0449          pCi/g Silver-108m                      U 0.00263      +/-0.0131  0.0115  +/-0.0131  0.0229          pCi/g Thallium-208                          0.273    +/-0.0346  0.0112  +/-0.0346  0.0224          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U    0.0275    +/-0.020  0.01 33  +/-0.020  0.0308          pCi/g            NXL3 04/02/07 1905 621126 The following Prep Methods were performed Method            Description                                            Analyst    Date            Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBI        03/29/07          1120    621099 The following Analytical Methods were performed Miethod          Description I                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery %        Acceptable Limnits Page 69 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171  - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                93 12-0010-1 14F            Project:      YANK01204 Sample ID:                        183243014                    Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU      MDA        Units      DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%      Acceptable Limits Strontium Carrier                GFPC, SrOO, solid-ALL FSS                79            (25%-1 25%)
Notes:
The Qualifiers in this report are defined as follows:
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 70 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171    -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address :  362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-1 14FS                Project:        YANK01204 Sample ID:                        183243015                        Client ID: YANK001 Matrix:                            TS                                Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          4.83%
Parameter                  Qualifier  Result  Uncertainty      LC      TPU        MDA          Units          DF Analyst Date      Time Batch l%
Rad Gamma Spec! Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                          0.872    +1-0.137  0.0364  +/-0.137    0.0728          pCi/g              MIHI    04/03/07 1914 621152 Americium-241                    U    0.0245    +/-0.0808  0.0682  +/-0.0808      0.136          pCi/g Bismuth-212                            0.526    +1-0.155  0.0825  &#xf7;1-0.155      0.165          pCi/g Bismuth-214                            0.731    +/-0.087    0.022  +/-0.087      0.044          pCi/g Cesium-134                      UI      0.00  +/-0.0231  0.0139  +/-0.0231    0.0278          pCi/g Cesium-137                            0.458    +/-0.0465  0.0113  +/-0.0465    0.0225          pCilg Cobalt-60                      UI      0.00  +/-0.0281    0.0117 +/-0.0281    0.0233          pCi/g Europium-152                    U -0.0087      +/-0.0516    0.0316 +/-0.0516    0.0631          pCi/g Europium-154                    U    0.0398    +/-0.0701    0.0372 +/-0.0701    0.0744          pCi/g Europium-iSS                    U    0.0526    +/-0.0449    0.0373 +/-0.0449    0.0746          pCi/g Lead-212                              0.783    +/-0.0719    0.0182 +/-0.0719    0.0364          pCi/g Lead-214                              0.816    +/-0.0898    0.0213 +/-0.0898    0.0425          pCi/g Manganese-54                    UI      0.00  +/-0.0167    0.0102 +/-0.0167    0.0204          pCi/g Niobium-94                      U -0.00182    +/-0.0123    0.0104 +/-0.0123    0.0208          pCi/g Potassium-40                            10.7    +/-0.877    0.0936  +/-0.877      0.187          pCi/g Radium-226                            0.731    +/-0.087    0.022  +/-0.087      0.044          pCi/g Silver-108m                      U 0.00747      +/-0.0126    0.0114 +/-0.0126    0.0228          pCi/g Thallium-208                          0.236    +/-0.0335    0.0113 +/-0.0335    0.0225          pCi/g Rad Gas Flow Proportional Counting GFPC, SOO0, solid-ALL FSS Strontium-90                    U    0.012    +/-0.0191    0.0145 +/-0.0191    0.0332          pCi/g              NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method            Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBIl          03/29/07          1120    621099 The following Analytical Methods were performed Method            Description 1                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery      Test                                  Recovery%          Acceptable Limits Page 71 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - wvww.gel.com Certificate of Analysis Company        Connecticut Yankee Atomtic Power Address        362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  93 12-0010-1 14FS              Project:      YANK01204 Sample ID:                        183243015                      Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU        NMA          Units        DF Analyst Date      Time Batch A~
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  79            (25%-I125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A  The TIC is a suspected aldol-condensation product B  For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD  Results are either below the MDC or tracer recovery is low C  Analyte has been confirmed by GCJMS analysis D  Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul  Gamma Spectroscopy--Uncertain identification X  Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y  QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 72 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-1 15F                Proiect:        YANK01204 Sample ID:                        183243016                        Client ID:      YANK001 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          1.87%
Parameter                    Qualifier    Result  Uncertainty        LC    TPU      MDA          Units          DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.920    +/-0.167  0.0435  +/-0.167  0.0869          pCi/g              MJH1 04/03/07 1915 621152 Americium-24 I                  U    0.0344  +/-0.0601    0.0525  +/-0.0601    0.105          pCi/g Bismuth-212                              0.385    +/-0.167  0.0913  +/-0.167    0.183          pCi/g Bismuth-214                            0.640  +/-0.0811    0.02 14 +/-0.0811  0.0427          pCi/g Cesium-134                      UI        0.00  +/-0.0236    0.0154  +/-0.0236  0.0307          pCi/g Cesium-]137                        U 0.00748    +/-0.0147    0.0129  +/-0.0147  0.0259          pCilg Cobalt-60                          U 0.00165    +/-0.0148    0.0127  +/-0.0148  0.0253          pCi/g Europium-152                    UI        0.00  +/-0.0555    0.0308  +/-0.0555  0.0616          pCi/g Europium-154                    U -0.00662    +/-0.0475    0.0405  +/-0.0475  0.0809          pCi/g Europium-ISS                      U    0.0376  +/-0.0423    0.0351  +/-0.0423  0.0701          pCi/g Lead-21 2                              0.939  +/-0.0822    0.0176  +/-0.0822  0.0352          pCi/g Lead-214                                0.706  +/-0.0815    0.0216  +/-0.0815  0.0431          pCi/g Manganese-54                    UI      0.00  +/-0.0161      0.011 +/-0.0161  0.0219          pCi/g Niobium-94                        U 0.00551      +/-0.013  0.0117  +/-0.013  0.0235          pCi/g Potassium-40                              16.4    +/-1.15    0.104    +/-1.15    0.208          pCi/g Radium-226                              0.640  +/-0.0811    0.0214  +/-0.0811  0.0427          pCi/g Silver-108m                      U 0.00539      +/-0.0129  0.0103  +/-0.0129  0.0206          pCi/g Thallium-208                            0.281  +/-0.0377    0.0113  +/-0.0377  0.0226          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, so/id-ALL FSS Strortium-90                      U -0.00657    +/-0.0159  0.0146 +/-0.0159      0.035          pCi/g              NXL3 04/03/07 1421 621126 The following Prep Methods were performed Method              Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            JMB1        03/29/07          1120    621099 The following Analytical Methods were performed Method              Description EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified 3                  EPA 905.0 Modified Page 73 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-1 15F              Project:      YANK01204 Sample ID:                        183243016                    Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                74            (25 %-1 25%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected
* Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RE h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 74 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                9312-0010-11 6F                Project:        YANK0 1204 Sample ID:                        183243017                      Client ID: YANKOOI Matrix:                          TS                              Vol. Recv.:
Collect Date:                    26-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        4.56%
Parameter                  Qualifier    Result  Uncertainty      LC    TPU      MDA          Units          DF Analyst Date        Time Batch A~
Rad Ganmna Spec Analysis Gamma,So/id-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            1.05    +/-0.173  0.0428  +/-0.173  0.0855          pCi/g              MJH1 04/03/07 1918 621152 Americium-241                    U    0.0107  +/-0.0917  0.0745  +/-0.0917    0.149          pCilg Bismuth-212                            0.554    +/-0.185  0.0899  +/-0.185    0.180          pCi/g Bismuth-2 14                          0.662  +/-0.0843  0,0235  +/-0.0843    0.047          pCi/g Cesium-134                      UI      0.00    +/-0.026  0.0158  +/-0.026  0.0316          pCi/g Cesium-137                      U -0.00385    +/-0.0142    0.012 +/-0.0142    0.024          pCilg Cobalt-60                        U    0.0025  +/-0.0149    0.0126 +/-0.0149  0.0252          pCi/g Europium-152                    U -0.0139    +/-0.0509    0.0315 +/-0.0509    0.063          pCilg Europium-154                    U -0.00395    +1-0.0516  0.0412 +1-0.0516  0.0823          pCilg Europium-155                    U    0.0722    +/-0.054  0.0396  +/-0.054  0.0792          pCi/g Lead-212                                1.01    +/-0.118  0.0198  +/-0.118  0.0395          pCilg Lead-214                              0.821  +/-0.0995    0.0227 +/-0.0995  0.0453          pCilg Manganese-54                    U    0.0231  +/-0.0239    0.0119 +/-0.0239  0.0237          pCilg Niobium-94                      U 0.00574    +/-0.0131    0.0114 +/-0.0131  0.0228          pCi/g Potassium-40                            16.6    +1-1.24    0.101    +1-1.24  0.203          pCi/g Radium-226                            0.662  +/-0.0843    0.0235 +/-0.0843    0.047          pCi/g Silver-108m                      U 0.00197      +/-0.0123    0.011 +/-0.0123    0.022          pCi/g Thallium-208                          0.3 19  +/-0.0372    0.011 +/-0.0372  0.0221          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U 0.00116      +1-0.015  0.0125  +/-0.015  0.0286          pCi/g              NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method            Description                                          Analyst    Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBI        03/29/07          1120    621099 The following Analytical Methods were performed Method              Description 1                  EML HASL 300,4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Page 75 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - wvww.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address :    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-1 16F              Project:      YANK01204 Sample ID:                        183243017                    Client ID: YANKOOlI Vol. Recv.:
Parameter                  Quallifier  Result  Uncertainty    LC    TPU        MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, SOO0, solid-ALL FSS                84            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R  Sample results are rejected
* Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI  Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +f-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 76 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-1 17F                Project:        YANK01 204 Sample ID:                          183243018                      Client ID: YANKOO 1 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                          Client Moisture:                          3.0 1%
Parameter                    Qualifier  Result  Uncertainty        LC    TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                              1.09    +/-0.166    0.0459  +/-0.166  0.09 17        pCi/g            MJ`HI 04/03/07 1919 621152 Americium-24 1                  U    0.0304  +/-0.0252    0.0211  +/-0.0252  0.0421          pCi/g Bismuth-212                            0.700    +/-0.252      0.106  +/-0.252    0.212          pCi/g Bismuth-214                            0.798    +/-0.112    0.0263  +/-0.112  0.0525          pCi/g Cesium-134                      UI        0.00    +/-0.024    0.01 76  +/-0.024  0.0351          pCi/g Cesium-137                              0.291  +/-0.0424    0.0134  +/-0.0424  0.0267          pCi/g Cobalt-60                        U    0.0221    +/-0.0179    0.0161  +/-0.0179  0.0322          pCi/g Europium-152                      U 0.00358      +/-0.0514      0.035 +/-0.0514    0.070          pCi/g Europium-154                      U -0.0221      +/-0.0521    0.0427  +/-0.0521  0.0853          pCi/g Europium-ISS                      U    0.0609    +/-0.0466    0.0342 +/-0.0466  0.0684          pCi/g Lead-212                                0.982    +/-0.117    0.0193  +/-0.117  0.0385          pCi/g Lead-214                                0.886    +/-0.106    0.0252  +/-0.106  0.0503          pCi/g Manganese-54                      U    0.0142    +/-0.0186    0.0146  +/-0.0186  0.0292          pCi/g Niobium-94                        U 0.00509      +/-0.016    0.0137  +/-0.016  0.0274          pCi/g Potassium-40                              15.6      +/-].11    0.131    +/-1. 11  0.262        pCi/g Radium-226                              0.798    +/-0.112    0.0263  +/-0.112  0.0525          pCi/g Silver-I 08m                      U 0.00373      +/-0.0141    0.0125 +/-0.0141  0.0249          pCi/g Thiallium-208                          0.295    +/-0.0426    0.0139  +/-0.0426  0.0278          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                      U    0.013    +/-0.0166    0.0122 +/-0.0166  0.0283          pCi/g            NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method              Description                                            Analyst      Date            Time    Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                              JMB1        03/29/07        1120    621099 The following Analytical Methods were performed Method              Description I                    EML HASL 300, 4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Lim-its Page 77 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-1 17F              Project:      YANK01204 Sample ID:                          183243018                    Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                  Recovery%      Acceptable Limaits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                87            (25%-1 25%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
  < Result is less than value reported
  &#xfd;> Result is greater than value reported A The TIC is a suspected aldol-condensation product 1B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
13D Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J1 Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI  Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 78 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-1 18F                  Proiect:        YANK0 1204 Sample ID:                        183243019                        Client ID: YANK001 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          3.88%
Parameter                  Qualifier    Result  Uncertainty        LC    TPU        MDA          Units          DF Analyst Date      Time Batch a%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            0.995    +1-0.175  0.0419  +/-0.175    0.0838          pCi/g              MJHI 04/03/07 1920 621152 Americium-241                    U    0.0161  +/-0.0597    0.0559  +/-0.0597    0.112          pCi/g Bismuth-212                            0.494    +/-0.181  0.0975  +/-0.181    0.195          pCi/g Bismuth-214                            0.632  +/-0.0851    0.0231  +/-0.0851    0.0463          pCi/g Cesium-134                      UI      0.00  +/-0.0225    0.0156  +/-0.0225    0.0312          pCilg Cesium-] 37                          0.0619    +/-0.0238  0.0136  +/-0.0238    0.0271          pCi/g Cobalt-60                        U -0.00246    +1-0.0151    0.0126  +/-0.0151    0.0253          pCi/g Europium-152                    U -0.0371      +/-0.0421    0.0329  +/-0.0421    0.0657          pCi/g Europium-154                    U -0.0107    +/-0.0475    0.0399  +/-0.0475    0.0797          pCi/g Europium-155                    U    0.0313  +/-0.0591    0.0356  +/-0.0591    0.0712          pCi/g Lead-212                                0.978  +/-0.0867    0.019 +/-0.0867    0.0379          pCi/g Lead-214                                0.713    +/-0.087    0.024  +/-0.087    0.048          pCi/g Manganese-54                    U    0.0159    +/-0.0166    0.013 +/-0.0166    0.0261          pCi/g Niobium-94                      U    0.0126    +/-0.0132  0.0119  +/-0.0132    0.0238          pCi/g Potassium-40                            16.0      +/-1.25    0.111    +/-1.25    0.223          pCi/g Radium-226                              0.632  +/-0.085 1  0.0231  +/-0.0851    0.0463          pCi/g Silver-108m                      U 0.00018      +/-0.0132    0.0114 +/-0.0132  .0.0227          pCi/g Thallium-208                            0.319  +/-0.0391  0.0122  +/-0.0391    0.0244          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U 0.00596      +/-0.020  0.0161  +/-0.020    0.0364          pCi/g            NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method            Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            IMBI          03/29/07          1120    621099 The following Analytical Methods were performed Method            Description 1                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Limnits Page 79 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Anallsis Company:      Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils P04* 002332 Client Sample ID:                  9312-0010-1 18F            Project:      YANKOI1204 Sample ID:                          183243019                  Client ID: YANKOGI Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU      MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%      Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                80            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD1 Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCJMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 80 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  -  (843) 556-8171    -  www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :362      Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-1 19B                  Project:      YANK0 1204 Sample ID:                        183243020                        Client ID: YANKO0l Matrix:                            TS                                Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          6.09%
Parameter                    Qualifier    Result  Uncertainty      LC    TPU        MDA          Units        DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.594    +1-0.121  0.0367  +/-0.121    0.0734          pCi/g            MJHI 04/03/07 1921 621152 Americium-241                    U    0.043    +/-0.0726  0.0572 +/-0.0726      0.114          pCilg Bismuth-212                              0.394    +/-0.148  0.0825  +/-0.148      0.165          pCilg Bismuth-214                            0.525    +/-0.0762  0.0227 +/-0.0762    0.0454          pCilg Cesium-I 34                      U    0.0241    +/-0.022  0.0132  +/-0.022    0.0264          pCilg Cesium-137                                2.25    +/-0.210    0.012  +/-0.210      0.024          pCi/g Cobalt-60                                0.125  +/-0.0239  0.0103 +/-0.0239    0.0205          pCilg Europium-152                    U -0.0403      +/-0.0412  0.0338 +/-0.0412    0.0675          pCi/g Europium-154                      U 0.000828    +/-0.0424  0.0358 +/-0.0424    0.07 15          pCi/g Europium-I 55                    U    0.0101    +/-0.0409  0.0376 +/-0.0409    0.0751          pCi/g Lead-212                                0.481  +1-0.0497  0.0188 +/-0.0497    0.0376          pCi/g Lead-214                                0.548  +/-0.0711  0.0245 +/-0.0711      0.049          pCi/g Manganese-54                    U 0.00432      +/-0.0127  0.0113 +/-0.0127    0.0225          pCi/g Niobium-94                      U 0.000943    +/-0.0121  0.0103 +/-0.0121    0.0206          pCilg Potassium-40                            10.2    +/-0.798  0.0877  +/-0.798      0.175          pCilg Radium-226                              0.525  +/-0.0762  0.0227 +/-0.0762    0.0454          pCi/g Silver-108m                      U -0.00736    +/-0.0149    0.013 +/-0.0149      0.026          pCi/g Thallium-208                            0.156  +/-0.0324  0.0115 +/-0.0324      0.023          pCilg Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U 0.00753      +/-0.0192  0.0151 +/-0.0192    0.0349          pCi/g              NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method              Description                                          Analyst        Date            Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            JMBI          03/29/07          1120    621099 The following Analytical Methods were performed Method              Description I              EML HASL 300,4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery        Test                                Recovery%            Acceptable Limits Page 81 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171  - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils P04* 002332 Client Sample ID:                  9312-0010-1 19B              Project:    YANK01204 Sample ID:                        183243020                    Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU        MDA        Units        DF Analyst Date    Time Batch A~
SurrogateffTracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                68            (25%-I125%)
Notes:
The Qualifiers in this report are defined as follows
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit
* Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 82 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address :    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-120B                  Project:        YANK01204 Sample ID:                        183243021                      Client ID: YANKOOI Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          14.8%
Parameter                    Qualifier    Result  Uncertainty      LC      TPU      MDA          Units          DF Analyst Date        Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                              1.39    +/-0.246  0.0674  +1-0.246    0.135          pCi/g              MJH1 04/03/07 0945 621149 Americium-241                    U    0.0979    +/-0.115  0.0889  +/-0.115    0.178          pCi/g Bismuth-212                              1.12    +/-0.377    0.146  +/-0.377    0.292          pCi/g Bismuth-214                              1.59    +/-0.174  0.0361  +/-0.174  0.0721          pCi/g Cesium-134                      UI      0.00    +/-0.032  0.0253  +/-0.032  0.0505          pCilg Cesium-I 37                              0.37 1  +/-0.053  0.0204  +/-0.053  0.0408          pCi/g Cobalt-60                        U      0.015  +/-0.0272  0.0227  +/-0.0272  0.0454          pCi/g Europium-152                      U    -0.056    +/-0.0832  0.0513  +/-0.0832    0.102          pCi/g Europium-154                      U -0.0347      +/-0.0774  0.0587  +/-0.0774    0.117          pCi/g Europium-I 55                    U    0,0665    +/-0.0746  0.0563  +/-0.0746    0.113          pCi/g Lead-212                                  1.45    +/-0.139  0.0312  +/-0.139  0.0623          pCi/g Lead-214                                  1.76    +/-0.188  0.0362  +/-0.188  0.0723          pCi/g Manganese-54                      U 0.00759      +/-0.0267  0.0199  +/-0.0267  0.0397          pCi/g Niobium-94                        U 0.00613      +/-0.0219    0.019 +/-0.0219    0.038          pCi/g Potassium-40                              22.5      +1-1.65    0.146    +1-1.65  0.291          pCi/g Radium-226                                1.59    +/-0.174  0.0361  +/-0.174  0.0721          pCi/g Silver-108m                      U -0.0115      +/-0.0212  0.0175  +/-0.0212  0.0349          pCi/g Thiallium-208                            0.471  +/-0.0633  0.0188  +/-0.0633  0.0376          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                      U 0.000128    +/-0.0193  0.0162 +/-0.0193    0.0371          pCi/g              NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method              Description                                            Analyst    Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            IMBI        03/29/07          1125    621101 The following Analytical Methods were performed Method              Description I              EML HASL 300,4.5.2.3 2                  EPA 905.0 Modified Page 83 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  9312-0010-120B              Project:      YANKOI2O4 Sample ID:                        183243021                    Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                74            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI  Gamma Spectroscopy---Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 84 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address :362      Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-121lB                Proiect:        YANKO 1204 Sample ID:                        183243022                      Client ID: YANK001 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          8.55%
Parameter                  Qualifier    Result  Uncertainty        LC    TPU      MDA          Units          DF Analyst Date      Time Batch A%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            0.470    +/-0.163  0.0659  +/-0.163    0.132          pCi/g              MJHI1 04/03/07 0946 621149 Americium-241                    U -0.0359      +/-0.0852  0.0715  +/-0.0852    0.143          pCi/g Bismuth-212                            0.432    +/-0.272    0.134  +/-0.272    0.267          pCi/g Bismuth-214                      UI      0.00    +/-0.102    0.070  +/-0.102    0.140          pCi/g Cesium-134                        U    0.0183    +/-0.0287  0.0228  +/-0.0287  0.0455          pCi/g Cesium-137                            0.234    +/-0.0446  0.0183  +/-0.0446  0.0367          pCi/g Cobalt-60                        U    0.0135    +/-0.0189  0.0178  +/-0.0189  0.0356          pCi/g Europium-152                    U    0.0184    +/-0.0759  0.0466  +/-0.0759    0.093          pCi/g Europium-154                    U    0.0854    +/-0.0666  0.0631  +/-0.0666    0.126          pCi/g Europium-155                    U    0.0542    +/-0.0658  0.0514  +/-0.0658    0.103          pCi/g Lead-212                              0.508    +/-0.0751  0.0287  +/-0.0751  0.0573          pCi/g Lead-214                                0.555    +/-0.101  0.0319  +/-0.101  0.0638          pCi/g Manganese-54                    U -0.0232      +/-0.0209  0.0166  +/-0.0209  0.0331          pCi/g Niobium-94                      U 0.00826      +/-0.0182  0.0167  +/-0.0182  0.0333          pCi/g Potassium-40                            11.1      +1-1.05    0.110    +1-1.05    0.220        pCi/g Radium-226                            0.520    +/-0.102  0.0308  +/-0.102  0.0615          pCi/g Silver-108m                      U -0.0101      +/-0.0188  0.0164  +/-0.0188  0.0328          pCi/g Thallium-208                            0.186  +/-0.0468  0.0163  +/-0.0468  0.0326          pCi/g Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90                    U    0.0158    +/-0.021  0.0157  +/-0.021  0.0359          pCi/g              NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method            Description                                            Analyst      Date            Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBI        03/29/07          1125    621101 The following Analytical Methods were performed Method            Description I                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Page 85 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - wvww.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address :    362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-121B              Project:      YANK01204 Sample ID:                        183243022                    Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU      MDA          Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                72            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit
* Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 86 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  931 2-0010-122B                Proiect:        YANK0 1204 Sample ID:                          183243023                      Client ID:      YANKOO 1 Matrix:                            TS                              Vol. Recv.:
Collect Date:                      26-MAR-07 Receive Date:                      29-MAR-07 Collector:                          Client Moisture:                          6.73%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU      MDA          Units        DF Analyst Date      Time Batch 1'%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            0.684    +/-0.224  0.0792  +/-0.224    0.158        pCi/g              MJHI 04/03/07 0947 621149 Americium-241                  U      0.0194  +/-0.0414    0.0353  +/-0.0414  0.0705          pCi/g Bismuth-212                            0.447    +/-0.296    0.175  +/-0.296    0.349        pCi/g Bismuth-214                            0.557    +/-0.125  0.0461  +/-0.125  0.0921          pCilg Cesium-134                      U      0.048  +/-0.0373    0.0301  +/-0.0373  0.0602          pCilg Cesium-] 37                      U    0.0335  +/-0.0533    0.0257  +/-0.0533  0.0515          pCilg Cobalt-60                        U    0.01 02  +/-0.0374  0.0271  +/-0.0374  0.0542          pCi/g Europium-152                    U -0.0157      +/-0.0751  0.0575  +1-0.0751    0.115        pCi/g Europium-154                    U    0.0132    +/-0.0845  0.0728  +/-0.0845    0.145        pCi/g Europium- 155                    U    0.0541    +/-0.0629  0.0596  +/-0.0629    0.119        pCi/g Lead-212                                0.457    +/-0.0783  0.0337  +/-0.0783  0.0673          pCi/g Lead-214                                0.522  +/-0.0983  0.0433  +/-0.0983  0.0865          pCi/g Manganese-54                    UI .900E-05    +/-0.0249  0.0218  +/-0.0249  0.0436          pCi/g Niobium-94                      U -0.00193      +/-0.0258  0.0217  +/-0.0258  0.0435          pCi/g Potassium-40                              9.91      +1-1.13    0.194    +1-1.13    0.387        pCi/g Radium-226                              0.557    +/-0.125  0.0461  +/-0.125  0.0921          pCi/g Silver-108m                      U-0.000262      +/-0.0225  0.0198 +/-0.0225    0.0397          pCi/g Thallium-208                            0.189    +1-0.0633  0.0211 +/-0.0633    0.0421          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U 0.00906      +/-0.0223  0.0176 +/-0.0223    0.0403          pCi/g              NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method              Description                                            Analyst      Date            Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                              1MB 1        03/29/07          1125    621101 The following Analytical Methods were performed Method            Description I              EML HASL 300,4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery %        Acceptable Limits Page 87 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-122B              Project:      YANK01204 Sample ID:                        183243023                    Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU        MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                59            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Anallyte concentration is not detected above the detection limit R Sample results are rejected
* Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 88 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                9312-0010-123B                  Project:        YANK01204 Sample ID:                        183243024                        Client ID: YANKOO 1 Matrix:                          TS                              Vol. Recv.:
Collect Date:                    26-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        .45%
Parameter                    Qualifier    Result  Uncertainty      LC      TPU      MDA          Units          DF Analyst Date        Time Batch IN Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.593    +/-0.163  0.0561  +/-0.163    0.112          pCi/g              MJH1 04/03/07 0948 621149 Americium-24 1                  U -0.00132    +/-0.0951    0.0808  +/-0.0951    0.162          pCi/g Bismuth-212                      U      0.273    +/-0.169    0.164  +/-0.169    0.327          pCi/g Bismuth-214                            0.400    +/-0.101  0.0326  +/-0.101  0.0653          pCilg Cesium-134                      U      0.015  +/-0.0236    0.0207  +/-0.0236  0.0414          pCi/g Cesium-137                              0.340  +/-0.0526    0.0184  +/-0.0526  0.0368          pCilg Cobalt-60                        U 0.00895    +/-0.0243    0.02 16 +/-0.0243  0.0431          pCi/g Europium-152                    U 0.00468    +/-0.0598    0.0494  +/-0.0598  0.0987          pCilg Europium-I 54                  U 0.00596      +/-0.0743    0.0576  +/-0.0743    0.115          pCi/g Europium-iSS                    U -0.00709    +/-0.0654    0.0515  +/-0.0654    0.103          pCilg Lead-212                              0.616  +/-0.0732    0.0286  +/-0.0732  0.0572          pCilg Lead-214                              0.560    +/-0.095  0.0348  +/-0.095  0.0695          pCi/g Manganese-54                    U    0.027  +/-0.0219    0.0206  +/-0.0219  0.0412          pCilg Niobium-94                      U-0.000645    +/-0.0182  0.0158  +/-0.0182  0.0316          pCi/g Potassium-40                            10.4    +/_1.11    0.202    +/-].]11  0.404          pCilg Radium-226                            0.400    +/-0.101  0.0326  +/-0.101  0.0653          pCilg Silver-108m                      U -0.00929    +/-0.0199  0.0167  +/-0.0199  0.0333          pCi/g Thallium-208                            0.215  +/-0.0421    0.0183  +/-0.0421  0.0366          pCilg Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U    0.0229    +/-0.0235  0.0171  +/-0.0235  0.0389          pCi/g              NXL3 04/02/07 1906 621126 The following Prep Methods were performed Method              Description                                            Analyst    Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            JMBI1      03/29/07          1125    621101 The following Analytical Methods were performed Method            Description 1                  EML HASL 300, 4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%        Acceptable Limits Page 89 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Anallsis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-123B                Project:      YANK01204 Sample ID:                        183243024                    Client ID: YANKOOlI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU        MDA        Units        DF Analyst Date      Time Batch A~
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL ESS                75            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL ht Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 90 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils P04* 002332 Client Sample ID:                  9312-0010-1-017-13              Project:        YANK01 204 Sample ID:                        183243025                        Client ID:      YANKOOI Matrix:                            TS                              Vol. Recv.:
Collect Date:                      22-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          6.86%
Parameter                    Qualifier    Result  Uncertainty      LC      TPU      MDA          Units        DF Analyst Date      Time Batch IN Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228                              1.01    +1-0.185  0.0499  +1-0.185  0.0998          pCi/g            MJHI 04/03/07 0949 621149 Americium-241                    U    0.0389  +/-0.0942    0.0798  +/-0.0942    0.159          pCi/g Bismuth-212                            0.383    +/-0.256    0.124  +/-0.256    0.247          pCi/g Bismuth-214                            0.516  +/-0.0843    0.0292  +/-0.0843  0.0584          pCi/g Cesium-I 34                      U    0.0295  +/-0.0254    0.0202  +/-0.0254  0.0403          pCi/g Cesium-137                              0.354  +/-0.0522    0.017  +/-0.0522  0.0339          pCi/g Cobalt-60                        U 0.00544        +/-0.021  0.0181  +/-0.021  0.0362          pCi/g Europium-152                      U -0.0111    +/-0.0532    0.0411  +/-0.0532  0.0821          pCi/g Europium-154                      U -0.0381    +/-0.0639    0.0511  +/-0.0639    0.102          pCi/g Europium-iSS                      U    0.01 32  +/-0.0624  0.0508  +/-0.0624    0.102          pCi/g Lead-212                                0.700    +/-0.0737  0.0266  +/-0.0737  0.0531          pCi/g Lead-214                                0.599    +/-0.0875  0.0309  +/-0.0875  0.0618          pCi/g Manganese-54                      U -0.00129    +/-0.0194  0.0169  +/-0.0194  0.0338          pCi/g Niobium-94                        U 0.000743    +/-0.0169  0.0145  +/-0.0169  0.0289          pCi/g Potassium-40                              12.5      +/-1.12    0.149    +/-1.12    0.299          pCi/g Radium-226                              0.516  +/-0.0843    0.0292  +/-0.0843  0.05 84          pCi/g Silver-i 08m                      U-0.000208      +/-0.017    0.015  +/-0.017    0.030          pCi/g Thallium-208                            0.196  +/-0.0415    0.0158  +/-0.0415  0.0316          pCi/g Rad Gas Flow Proportional Counting GFIPC, Sr9O, solid-ALL ESS Strontium-90                      U    0.0151    +/-0.0227  0.0168 +/-0.0227    0.0397          pCi/g            NXL3 04/03/07 1421 621126 The following Prep Methods were performed Method              Description                                            Analyst      Date            Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            JMBI        03/29/07          1125    621101 The following Analytical Methods were performed Method              Description 1                    F.MLHASL 3004 52 3 2                    EPA 905.0 Modified 3                  EPA 905.0 Modified Page 91 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  93 12-0010-1-017-B3            Project:      YANK01204 Sample ID:                        183243025                      Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC      TPU      MDA          Units        DF Analyst Date    Time Batch 1k Surrogate/Tracer recovery        Test                                  Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  70            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 92 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address :362      Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-1-01 8-B              Project:        YANK01204 Sample ID:                        183243026                        Client ID:      YANKOO I Matrix:                            TS                              Vol. Recv.:
Collect Date:                      22-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          3.63%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU      MDA          Units        DF Analyst Date      Time Batch A~
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.928    +/-0.203  0.0687    +/-0.203    0.137          pCi/g              MIHI 04/03/07 0950 621149 Americium-241                    U    0.0652    4/-0.0622  0.0986  +/-0.0622    0.197          pCi/g Bismuth-212                            0.683    +/-0.260    0.16 1  +/-0.260    0.321          pCi/g Bismuth-214                            0.760    +/-0.134  0.0426    +/-0.134  0.0852          pCi/g Cesium-134                      UI      0.00  F./-0.0445  0.0266  +/-0.0445  0.0531          pCi/g Cesium-137                                2.45    +/-0.206  0.0209    +/-0.206  0.0417          pCi/g Cobalt-60                              0.109    F/-0.0424  0.0192  +/-0.0424  0.0383          pCi/g Europium-152                      U    0.0857    +/-0.0846  0.0657  +/-0.0846    0.131          pCi/g Europium-154                      U -0.00911    +/-0.073 1  0.0606  +1-0.0731    0.121          pCi/g Europium-155                      U -0.0132      +/-0.077    0.0691  +/-0.077    0.138          pCi/g Lead-212                                0.957    +/-0.101  0.0366    +/-0.101  0.0732          pCi/g Lead-21 4                                0.937    +/-0.133    0.0446  +/-0.133  0.0892          pCi/g Manganese-54                      U    0.01 05  +/-0.0274    0.02 13 +/-0.0274  0.0427          pCi/g Niobium-94                        U      0.032  +/-0.0263  0.01 89  +/-0.0263  0.0378          pCi/g Potassium-40                              16.0      +1-1.47    0.165    +/-1.47  0.330          pCi/g Radium-226                              0.760    +/-0.134    0.0426  +/-0.134  0.0852          pCi/g Silver-108m                      U    0.0105    +/-0.0269    0.0239  +/-0.0269  0.0477          pCi/g Thallium-208                            0.281    +/-0.062    0.021  +/-0.062    0.042        pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U    0.0237    +/-0.0208    0.0145 +/-0.0208    0.0334          pCi/g              NXL3 04/02/07 1907 621126 The following Prep Methods were performed Method            Description                                            Analyst      Date            Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                              IMBI1        03/29/07          1125    621101 The following Analytical Methods were performed Method            Description I              EMIL HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Limits Page 93 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                93 12-0010-1-018-B3          Project:      YANK01204 Sample ID:                        183243026                    Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU      MDA          units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                  77            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected
* Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 94 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171    -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-I-019-B                Project:        YANK0 1204 Sample ID:                        183243027                        Client ID: YANK001 Matrix:                            TS                                Vol. Recv.:
Collect Date:                      22-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          8.88%
Parameter                    Qualifier  Result  Uncertainty      LC      TPU        MDA          units          DF Analyst Date        Time Batch A~
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.821    +1-0,169  0.0637  +/-0.169      0.127          pCilg              MJH1 04/03/07 0951 621149 Americium-241                    U    0.0306    +/-0.0781    0.065  +/-0.0781      0.130          pCi/g Bismuth-212                            0.437    +/-0.265    0.122  +1-0.265      0.243          pCi/g Bismuth-214                            0.582    +/-0.100  0.0377  +/-0.100    0.0753          pCilg Cesium-134                        U    0.0427    +/-0.0276  0.0226  +/-0.0276    0.0452          pCi/g Cesium-137                                3.84    +/-0.340  0.01 89  +/-0.340    0.0378          pCi/g Cobalt-60                              0.158    +/-0.0381  0.0169  +/-0.0381    0.0337          pCi/g Europium-152                      U -0.0449      +/-0.0766  0.0613  +/-0.0766      0.122          pCilg Europium-154                      U    0.0341    +/-0.0746  0.0579  +/-0.0746      0.116          pCi/g Europium-155                      U    0.0192    +/-0.0611  0.0569  +/-0.0611      0.114          pCi/g Lead-212                                0.634    +/-0.0754  0.0316  +/-0.0754    0.0631          pCi/g Lead-214                                0.688    +/-0.103  0.0466  +/-0.103    0.0932          pCi/g Manganese-54                    U    0.0331    +/-0.0264  0.0167  +/-0.0264    0.0335          pCi/g Niobium-94                        U    0.016    +/-0.018  0.0163  +/-0.018    0.0326          pCi/g Potassium-40                            13.0      +/-1.10    0.138    +/-1.10    0.275          pCi/g Radium-226                            0.582    +/-0.100  0.0377  +/-0.100    0.0753          pCi/g Silver-108m                      U    0.0282    +/-0.026  0.0239  +/-0.026    0.0478          pCi/g Thallium-208                            0.196    +/-0.0521  0.0193  +/-0.0521    0.0386          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90                    U 0.00514      +/-0.0203  0.0164 +/-0.0203      0.0374          pCi/g              NXL3 04/02/07 1907 621126 The following Prep Methods were performed Method              Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            JMBI1        03/29/07          1125    621101 The following Analytical Methods were performed Method              Description I              EML HASL 300,4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%          Acceptable Limits Page 95 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-1-019-13            Project:      YANK01204 Sample ID:                        183243027                    Client ID: YANK001 Vol. Recv.:
Parameter                  Qualifier  Result    Uncertainty    LC    TPU        MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                72            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD1 Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit
* Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 96 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  -  (843) 556-8171    -  www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                9312-0010-1-020-B3                Project:      YANKO 1204 Sample ID:                        183243028                        Client ID: YANK001 Matrix:                          TS                                Vol. Recv.:
Collect Date:                    22-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        6.34%
Parameter                  Qualifier  Result  Uncertainty      LC      TPU        MDA          Units        DF Analyst Date      Time Batch A Rad Gammna Spec Anatlysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                          0.828    +/-0.216  0.079  +/-0.216      0.158          pCilg            MJH1 04/03/07 0952 621149 Americium-241                  U    0.0314    +/-0.119  0.0935  +/-0.119      0.187          pCi/g Bismuth-212                            0.560    +/-0.313  0.150  +/-0.313      0.299          pCi/g Bismuth-214                            0.609    +/-0.121  0.0421  +/-0.121    0.0842          pCi/g Cesium-134                      U    0.0342  +1-0.0453  0.0257  +/-0.0453    0.0513          pCilg Cesium-137                              3.02    +/-0.288  0.0216  +/-0.288    0.0431          pCi/g Cobalt-60                              0.136  +/-0.0524  0.0213  +/-0.0524    0.0425          pCilg Europium-152                    U-0.000804    +/-0.0884  0.0613  +/-0.0884      0.123          pCi/g Europium-1 54                  U-0.000203      +/-0.083  0.0634  +/-0.083      0.127          pCi/g Europium-ISS                    U    0.0529  +/-0.0743  0.0693  +/-0.0743      0.139          pCi/g Lead-21 2                              0.809    +/-0.0942  0.0353  +/-0.0942    0.0706          pCi/g Lead-214                              0.674    +/-0.122  0.0449  +/-0.122    0.0898          pCi/g Manganese-54                    U -0.00454    +/-0.0256  0.0182  +/-0.0256    0.0364          pCi/g Niobium-94                      U -0.00751    +/-0.0263    0.019 +/-0.0263    0.0379          pCi/g Potassium-40                            14.0    +/-1.30    0.172    +/-1.30      0.343        pCi/g Radium-226                            0.609    +/-0.121  0.0421  +/-0.121    0.0842          pCi/g Silver-108m                      U -0.00137    +/-0.0272  0.0227  +/-0.0272    0.0455          pCi/g Thallium-208                            0.198  +/-0.0529  0.0214  +/-0.0529    0.0428          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, so/id-ALL FSS Strontium-90                    U    0.0182    +/-0.0226  0.0168 +/-0.0226      0.0383          pCi/g            NXL3 04/02/07 1907 621126 The following Prep Methods were performed Method              Description                                          Analyst        Date            Time    Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            IMBI          03/29/07        1125    621101 The following Analytical Methods were performed Method            Description I              EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                Recovery%            Acceptable Limits Page 97 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                93 12-0010-1-020-B3            Project:      YANK0 1204 Sample ID:                        183243028                      Client ID: YANKO0l Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC      TPU        MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  75            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
  **    Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Anallyte has been confirmed by GCJMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +f-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 98 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  -  (843) 556-8171    -  www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-1-021-13                Project:        YANK0 1204 Sample ID:                        183243029                        Client ID: YANK001 Matrix:                            TS                                Vol. Recv.:
Collect Date:                      22-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          5.65%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU        MDA          Units        DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,So/id-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.853    +1-0.275    0.127  +/-0.275      0.254          pCi/g            MJIi 04/03/07 0953 621149 Americium-241                    U    0.0717    +1-0.0856  0.0535  +1-0.0856      0.107          pCi/g Bismuth-212                            0.537    +/-0.506    0.260  +/-0.506      0.519          pCi/g Bismuth-214                            0.755    +/-0.178  0.0694  +/-0.178      0.139          pCi/g Cesium-134                      UI        0.00  +/-0.0701  0.0458  +/-0.0701    0.0915          pCi/g Cesium-137                                1.46  +/-0.173  0.0346  +/-0.173    0.0692          pCi/g Cobalt-60                              0.134  +/-0.0723    0.040 +/-0.0723    0.0799          pCi/g Europium-152                    U    0.0181    +/-0.153  0.0936  +/-0.153      0.187          pCi/g Europium- 154                    U 0.00983      +/-0.116  0.0979  +/-0.116      0.196          pCi/g Europium-I 55                    U      0.053    +/-0.102    0.088  +/-0.102      0.176          pCi/g Lead-212                                0.877    +/-0.121  0.0487  +/-0.121    0.0974          pCi/g Lead-214                                0.825    +/-0.161  0.0664  +/-0.161      0.133          pCi/g Manganese-54                    U    0.0234    +/-0.0491  0.0328  +/-0.0491    0.0656          pCi/g Niobium-94                      UJ -0.0147    +/-0.0404    0.033 +/-0.0404    0.0659          pCi/g Potassium-40                              15.0    +/-1.57    0.274    +/-1.57    0.548          pCi/g Radium-226                              0.755    +/-0.178  0.0694  +/-0.178      0.139          pCi/g Silver-108m                      U 0.000363    +/-0.0373  0.0325  +/-0.0373    0.0649          pCi/g Thallium-208                            0.214  +/-0.0878  0.0348  +/-0.0878    0.0696          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U 0.00118      +/-0.023  0.0191  +/-0.023    0.0442          pCi/g            NXL3 04/03/07 1421 621126 The following Prep Methods were performed Method            Description                                            Analyst      Date            Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBI          03/29/07          1125    621101 The following Analytical Methods were performed Method            Description 1                  EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified 3                  EPA 905.0 Modified Page 99 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Analy:sis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-1-021-13            Project:      YANK01204 Sample ID:                        183243029                    Client ID: YANKOOlI Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU      MDA          Units        DF Analyst Date      Time Batch A%
Surrogate/Tracer recovery        Test                                  Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                72            (25%-I125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD1 Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL ht Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 100 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  -  (843) 556-8171    -  www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address :362      Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils P04* 002332 Client Sample ID:                9312-0010-1-022-B                Project:        YANK01204 Sample ID:                        183243030                        Client ID:      YANKOOI Matrix:                          TS                                Vol. Recv.:
Collect Date:                    22-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        8.81%
Parameter                    Qualifier    Result  Uncertainty      LC      TPU        MDA          Units          DF Analyst Date      Time Batch 1%
Rad Gajmma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            0.532    +/-0.133  0.0518  +/-0.133      0.104          pCi/g              MJIi 04/03/07 0954 621149 Americium-241                      U    0.0558  +1-0.0699  0.0584  +1-0.0699      0.117          pCi/g Bismuth-212                              0.387    +/-0.209    0.105  +/-0.209      0.210          pCilg Bismuth-214                              0.423    +1-0.0796  0.0284  +/-0.0796    0.0568          pCilg Cesium-134                        U    0.0206  +1-0.0189    0.018 +1-0.0189      0.036          pCilg Cesium-137                                1.78    +/-0.156  0.0155  +/-0.156      0.031          pCilg Cobalt-60                              0.0753  +/-0.0397    0.015 +/-0.0397      0.030          pCilg Europium-I 52                      U -0.00864    +/-0.0644  0.0495  +/-0.0644      0.099          pCi/g Europium-154                      U 0.00388    +/-0.0554  0.0474  +1-0.0554    0.0948          pCi/g Europium- 155                      U 0.00277      +/-0.054  0.0489  +/-0.054    0.0977          pCi/g Lead-212                                0.371  +/-0.0671  0.0295  +/-0.0671      0.059          pCi/g Lead-214                                0.551  +/-0.0865  0.0348  +/-0.0865    0.0695          pCi/g Manganese-54                      U -0.0102    +/-0.0177  0.0148  +/-0.0177    0.0297          pCi/g Niobium-94                        U-0.000419    +/-0.0173  0.0127  +/-0.0173    0.0253          pCi/g Potassium-40                              9.68    +/-0.914    0.145  +/-0.914      0.290          pCi/g Radium-226                              0.423  +/-0.0796  0.0284  +/-0.0796    0.0568          pCi/g Silver-I 08m                      U -0.00973    +/-0.0195  0.0167  +/-0.0195    0.0335          pCi/g Thallium-208                              0.124  +/-0.0397  0.0163  +/-0.0397    0.0325          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                            0.0319    +/-0.0202  0.0128 +/-0.0203      0.0299          pCi/g              NXL3 04/02/07 1907 621126 The following Prep Methods were performed Method              Description                                          Analyst      Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            JMB1          03/29/07          1125    621101 The following Analytical Methods were performed Method              Description 1                    EML HASL 300, 4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery          Test                                Recovery%          Acceptable Limits Page 101 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils P04* 002332 Client Sample ID:                  93 12-0010-1-022-B3            Project:      YANK01204 Sample lID:                        183243030                      Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU        NMA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr9O, solid-ALL FSS                  78            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target anallyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 102 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171      -  www.gel.com Certificate of Analy:sis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                  Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                9312-0010-1-023-13              Project:        YANK01204 Sample ID:                        183243031                      Client ID:      YANKOOlI Matrix:                          TS                              Vol. Recv.:
Collect Date:                    22-MAR-07 Receive Date:                    29-MAR-07 Collector:                        Client Moisture:                        2.28%
Parameter                  Qualifier    Result  Uncertainty      LC      TPU      MDA          Units          DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                          0.836    +/-0.231  0.0702  +/-0.231    0.140          pCi/g              MJHI 04/03/07 0955 621149 Americium-241                    U -0.0172      +/-0.040  0.0319  +/-0.040  0.0638          pCi/g Bismuth-212                      U    0.228    +/-0.336  0.176  +/-0.336    0.352          pCi/g Bismuth-214                            0.473    +/-0.101  0.042  +/-0.101  0.0839          pCi/g Cesium- 134                      U    0.0536    +/-0.037  0.0269  +/-0.037  0.0537          pCi/g Cesium-137                            0.397  +/-0.0664    0.024  +/-0.0664    0.048          pCi/g Cobalt-60                        U    0.0132  +/-0.0303  0.0268  +/-0.0303  0.0536          pCi/g Europium-152                    U -0.0329      +1-0.0668    0.054 +/-0.0668    0.108          pCi/g Europium-154                    U    0.0192  +/-0.0852  0.0736  +/-0.0852    0.147          pCi/g Europium-155                    U    0.0558  +/-0.0592  0.0554  +/-0.0592    0.111          pCi/g Lead-21 2                              0.640    +/-0.0907  0.0322  +/-0.0907  0.0643          pCi/g Lead-214                              0.596    +/-0.116  0.0395  +/-0.116    0.079          pCi/g Manganese-54                    U    0.0225    +/-0.0268    0.025 +/-0.0268  0.0501          pCi/g Niobium-94                      U 0.000493    +/-0.0273  0.0231  +/-0.0273  0.0461          pCi/g Potassium-40                            11.3    +/-1.35  0.221    +/-1.35  0.441          pCi/g Radium-226                            0.473    +/-0.101    0.042  +/-0.101  0.0839          pCi/g Silver-108m                      U -0.0128      +/-0.0236  0.0199  +/-0.0236  0.0397          pCi/g Thallium-208                          0.173  +/-0.0613  0.0214  +/-0.0613  0.0428          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                    U    0.010  +/-0.0181  0.0138 +/-0.0181    0.0321          pCi/g              NXL3 04/02/07 1907 621126 The following Prep Methods were performed Method            Description                                          Analyst    Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            IMBI        03/29/07          1125    621101 The following Analytical Methods were performed Method            Description I            EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Page 103 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-1-023-B3          Project:      YANK01204 Sample ID:                        183243031                    Client ID: YANKOOlI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC      TPU      MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                  Recovery%      Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  75          (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 104 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  wvww.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-1-024-B3              Proiect:        YANK0 1204 Sample ID:                        183243032                      Client ID:        YANK00I Matrix:                            TS                              Vol. Recv.:
Collect Date:                      22-MAR-07 Receive Date:                      29-MAR-07 Collector:                        Client Moisture:                          8.07%
Parameter(                  ~ualifier  Result  Uncertainty      LC      TPU      MDA          units          DF Analyst Date        Time Batch A~
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.498    +/-0.157  0.0576  +/-0.157    0.115          pCi/g              MJH1 04/03/07 0956 621149 Americium-241                    U    0.0409    +/-0.0693  0.0579  +/-0.0693    0.116          pCi/g Bismuth-212                            0.393    +/-0.231    0.130  +/-0.231    0.260          pCi/g Bismuth-21 4                            0.473  +/-0.0906    0.030  +/-0.0906  0.0599          pCi/g Cesium-134                        U    0.0232    +/-0.0214  0.0201  +/-0.0214  0.0402          pCi/g Cesium-I 37                            0.0567    +/-0.0306  0.0169  +/-0.0306  0.0337          pCi/g Cobalt-60                        U 0.00249      +/-0.0198  0.0168  +/-0.0198  0.0336          pCi/g Europium-152                      U -0.0972      +1-0.0599  0.0399  +/-0.0599  0.0797          pCi/g Europium-154                      U -0.0145      +/-0.0721  0.0593  +/-0.0721    0.119          pCi/g Europium-155                      U    0.0481    +/-0.0539    0.050  +/-0.0539  0.0999          pCi/g Lead-212                                0.592  +/-0.0673  0.0257  +/-0.0673  0.05 13          pCi/g Lead-214                                0.528  +/-0.0887  0.0318  +/-0.0887  0.0635          pCi/g Manganese-54                      U -0.00393    +/-0.0198  0.01 69 +/-0.0198  0.0339          pCi/g Niobium-94                        U 0.00555      +/-0.0184  0.0159  +/-0.0184  0.0318          pCi/g Potassium-40                              10.8    +/-1.03  0.126    +/-1.03  0.253          pCi/g Radium-226                              0.473  +/-0.0906    0.030  +/-0.0906  0.0599          pCi/g Silver-108m                      U 0.00365      +/-0.0184  0.0142  +/-0.01 84  0.0284          pCi/g Thallium-208                            0.221  +/-0.0445    0.017  +/-0.0445    0.034          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90                    U  0.00338    +/-0.0198  0.0161 +/-0.0198    0.0372          pCi/g              NXL3 04/02/07 1907 621126 The following Prep Methods were performed Method            Description                                            Analyst    Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMB 1        03/29/07          1125    621101 The following Analytical Methods were performed Method            Description I            EML HASL 300, 4.5.2.3 2                  EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%        Acceptable Limits Page 105 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analy:sis Company:      Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-1-024-B            Project:      YANKOI2O4 Sample ID:                        183243032                    Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU      NMA          Units        DF Analyst Date      Time Batch A~
Surrogate/Tracer recovery      Test                                Recovery%      Acceptable Limidts Strontium Carrier                GFPC, Sr9O, solid-ALL ESS                64            (25%-I125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RI. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 106 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171      -  www.gel.com Certificate of Analy:sis Company :Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                      Report Date:  April 5, 2007 Contact;    Mr. Jack McCarthy Project:      Soils P04* 002332 Client Sample ID:                  9312-0010-1-025-13                Project:        YANK01204 Sample ID:                          183243033                        Client ID: YANKO0l Matrix:                            TS                                Vol. Recv.:
Collect Date:                      22-MAR-07 Receive Date:                      29-MAR-07 Collector:                          Client Moisture:                          .528%
Parameter                    Qualifier    Result  Uncertainty        LC    TPU        MDA          Units          DF Analyst Date      Time Batch 1%
Rad Gammia Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.746    +/-0.183  0.0879  +/-0.183      0.176          pCi/g              MJHI 04/03/07 0957 621149 Americium-241                    U 0.00275      +/-0.0438  0.0369  +/-0.0438    0.0738          pCilg Bismuth-212                              0.477    +/-0.331    0.201  +/-0.331      0.402          pCilg Bismuth-214                              0.486    +/-0.123  0.0435  +/-0.123      0.087          pCilg Cesium-134                      UI      0.00    +/-0.0638    0.0241 +/-0.0638    0.0481          pCi/g Cesium-137                        U    0.041    +/-0.0463    0.0273 +/-0.0463    0.0546          pCilg Cobalt-60                          U    0.0225    +/-0.0349    0.0317 +/-0.0349    0.0633          pCi/g Europium-152                    U 0.00721      +/-0.0773    0.0646 +/-0.0773      0.129          pCi/g Europium-154                      U      0.035    +/-0.102    0.0884  +/-0.102      0.177          pCi/g Europium-ISS                    U -0.00105      +/-0.0611    0.0557 +/-0.0611      0.111          pCilg Lead-212                                0.525    +/-0.0815    0.0337 +/-0.0815    0.0674          pCilg Lead-214                                0.499    +1-0.101    0.041  +/-0.101    0.0819          pCilg Manganese-54                      U -0.0133      +/-0.0314    0.0254 +/-0.0314    0.0507          pCi/g Niobium-94                        U  0.0234    +/-0.0272    0.0256 +/-0.0272    0.0511          pCi/g Potassium-40                              10.2      +/-1.25    0.264    +1-1.25      0.527          pCi/g Radium-226                              0.486    +/-0.123    0.0435  +/-0.123      0.087          pCi/g Silver-108m                      U 0.00475      +/-0.023    0.0205  +/-0.023    0.0409          pCilg Thallium-208                            0.182    +/-0.0617    0.0223 +/-0.0617    0.0446          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                      U    0.0183    +/-0.0181    0.0128 +/-0.0181    0.0296          pCi/g              NXL3 04/02/07 2051 621126 The following Prep Methods were performed Method              Description                                            Analyst        Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                              JMBI          03/29/07          1125    621101 The following Analytical Methods were performed Method              Description I                    EML HASL 300, 4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery        Test                                  Recovery%            Acceptable Limits Page 107 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171    - wvww.gel.com Certificate of Analysis Company      Connecticut Yankee Atomic Power Address:    362 lnjun Hollow Rd East Hampton, Connecticut 06424                                                Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils P04* 002332 Client Sample ID:                  93 12-0010-1-025-B3            Project:      YANK01204 Sample ID:                          183243033                      Client ID: YANKOOI Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC      TPU        MDA        Units        DF Analyst Date      Time Batch A~
Surrogate/Tracer recovery        Test                                  Recovery%        Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                  75            (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected
* Analyte was analyzed for, but not detected above the M[DL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 108 of 122
 
QUALITY CONTROL DATA Page 109 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary                        Report Date: April 5, 2007
'lient :        Connecticut Yankee Atomic Power                                                              Page 1 of 13 362 Injun Hollow Rd East Hampton, Connecticut
.onktct:        Mr. Jack McCarthy Vorkorder:      183243 arnmame                                  NOM            Sample Qual        QC  Units    RPD%    REC%        Range    Anlst  Date Time ad Alpha Spec itch          621107 183245006 DUP
,mericium-241                                      u    -0.0394  U  -0.0452    pCilg      14          (0%  -100%)  GXR1  04/03/07 09:33 Uncert:    +/-0.0816    +1-0.0683 TPU:    +/-0.0818    +/-0.0684
.Uiium-242                                          U        0.00 U        0.00    pCi/g      0          (0%  -100%)
Uncert:      +/-0.083    +/-0.0676 TPU:      +/-0.083    +/-0. 067 6 uriu-243/244                                      U        0.00 U  -0.0555      pCi/g    200          (0% -100%)
Uncert:    +/-0.0794    +/-0.0411 TPU:    +/-0.0794    +/-0.0418 QC-1201305243      LCS
,mericium-24 I                          12.4                              11.2    pCi/g            90 (75%-125%)
Uncert:                      +/-1.06 TPU:                      +/-1.79
'urium-242                                                        U        0.00    pCilg Uncert:                  +/-0.0518 TPU:                  +/-0.0518 14.8                              14.2    pCi/g            96  (75%-125%)
Uncert:                      +/-1.19 TPU:                      +/-2.18 QC1201305240      MB U  -0.0487      pCilg
,mericium-241 Uncert:                  +1-0.0641 TPU:                  +1-0.0641
'Urium-242                                                        U        0.00    pCi/g Uncert:                  +/-0.0603 TPU:                  +/-0.0603
'Urium-243/244                                                    U    0.0459    pCi/g Uncert:                  +/-0.0861 TPU:                  +/-0.0863 QC1201305242  183245006 MIS
,mericium-241                            13.5      U    -0.0394          12.0    pCi/g            89  (75%-125%)
Uncert:    +/-0.0816        +/-1.16 TPU:    +/-0.0818        +/- 1.94
'Urium-242                                        U        0.00 U    0.0303    pCi/g Uncert:      +/-0.083    +/-0.0594 TPU:      +/-0.083    +/-0.0595 uriu-243/244                            16.1      U        0.00          14.9    pCi/g            93  (75%-125%)
Uncert:    +/-0.0794      +/-1.29 TPU:    +/-0.0794        +/-2.33 itch          622105 QC1201307489    183245006 DUP lutonium-241                                      U        -3.12 U      -8.22    pCi/g      0          (0%  - 100%) BXLI  04/05/07 15:31 Page 110 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171  - www.gel.com QC Summary Vorkorder:      183243                                                                                      Page 2 of 13 armname                                NOM            Sample Qua[        OC    Units    RPD%    REC%      Range    AnIst  Date Time ad Alpha Spec itch          622105 Uncert:      +1=10.1        +/-9.75 TPU:      +/-10.1        +/-9.75 QC1201307491      LCS lutonium-241                              138                                113    pCilg              82 (75%-125%)        04/05/07 16:04 Uncert:                      +1-14.9 TPU:                      +/-19.1 QC1201 307488      MB lutonium-241                                                      U        -1.9    pCilg                                  04/05/07 15:15 Uncert:
TPU:
QC1201307490    183245006 MS lutonium-24 1                            140      U      -3.12            120    pCilg              86 (75%-125%)        04/05/07 15:48 Uncert:        +/-10.1        +/-13.1 TPU:        +/-10.1        +/-17.4 itch          622351 QC1201308035    183245006 DUP lutonium-238                                      u      0.0429  U    -0.0147      pCi/g    409          (0% - 100%) GXRI  04/04/07 22:58 Uncert:    +/-0.0969    +/-0.0204 TPU:    +/-0.0971    +/-0.0204 lutonium-239/240                                  u        0.059 U      0.0306    pCi/g    63          (0% -100%)
Uncert:    +/-0.0943      +/-0.060 TPU:    +/-0.0946    +/-0.0601 QC1201 308037      LCS lutonium-238                                                      U      0.0151    pCi/g                (75%-I125%)
Uncert:                  +/-0.0602 TPU:                  +/-0.0603 lutonium-239/240                        12.7                              12.9    pCi/g            102 (75%-125%)
Uncert:                      +/-1 .20 TPU:                      +/-1.91 luCnum2030804M U  -0.00689      pCi/g Uncert:                  +/-0.0135 lutonium-239/4 TPU:                  +/-0.0135 U    -0.0138      pCi/g Uncert:                  +/-0.0191 TPU:                  +/-0.0192 QC1201308036    183245006 MIS lutonium-238                                      U      0.0429  U      0.0767    pCi/g                (75%-1 25%)
Uncert:    +/-0.0969      +/-0.105 TPU:    +/-0.0971      +/-0.106 lutonium-239/240                        13.7      U        0.059          14.9    pCi/g            109 (75%-125%)
Uncert:    +/-0.0943        +/-1.32 TPU:    +1-0.0946        +/-2.15 ad Gamma Spec itch          621149 QC1201305348    183245021 DUP
,ctinium-228                                                1.53          1.59    pCi/g      4          (0% - 100%) MJH1  04/03/07 12:58 Uncert:    +/-0.273      +/-0.286
                                                                      +/-0.286 Page 111 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder-      183243                                                                                    Page 3 of 13 armname                              NOM            Samnle Oual          OC    Units    RPD%    REC %    Ranee    AnIst Date Time ad Gamma Spec itch          621149 TPU:        +/-0.273
,mericium-24 I                                U    -0.0412    U    0.0296      pCi/g  1220        (0% -100%)
Uncert:      +/-0.127      +/-0.0983 TPU:        +/-0.127      +/-0. 0983
.ismuth-2 12                                              1.24          1.09    pCi/g    13        (0% -100%)
Uncert:      +/-0.343        +/-0.394 TPU:        +/-0.343        +/-0.394
*ismuth-2 14                                              1.72          1.65    pCilg      4          (0%  -20%)
Uncert:      +/-0.201        +/-0.195 TPU:        +1-0.201        +/-0.195
.esium-] 34                                  ul        0.00  UI        0.00    pCi/g      9      (0% -100%)
Uncert:    +/-0.0391      +/-0.0442 TPU:      +/-0.0391      +/-0.0442 lesium-1 37                                    U    0.00215    U  -0.00812      pCi/g    344        (0% -100%)
Uncert:    +/-0.0314      +/-0.03 28 TPU:      +/-0.0314      +/-0.0328
.obalt-60                                      U      0.0276    U  0.00443      pCi/g    145        (0% -100%)
Uncert:    +/-0.0282      +/-0.0349 TPU:      +/-0.0282      +/-0.0349
,uropium- 152                                  U    -0.0264    U    0.0111      pCi/g    492        (0% -100%)
Uncert:      +/-0.094      +/-0.0925 TPU:        +/-0.094      +/-0.0925
,uropium- 154                                  U      0.0221    U  -0.0225      pCi/g 22900        (0% -100%)
Uncert:      +/-0.100      +/-0.0951 TPU:        +/-0.100      +/-0.0951
,uropium-155                                  U        0.119  U      0.123    pCi/g    31        (0% -100%)
Uncert:      +/-0.114        +/-0.120 TPU:        +/-0.1 14      +/-0.120 ecad-21 2                                                1.71            1.72    pCi/g      I        (0%  -20%)
Uncert:      +/-0.159        +/-0. 155 TPU:        +/-0.159        +/-0. 155
.ead-214                                                  1.68            1.94    pCi/g      15        (0%  -20%)
Uncert:      +/-0.189        +/-0. 205 TPU:        +/-0.189        +/-0.205 langanese-54                                  U      0.0119  U  -0.00151      pCi/g    258        (0% -100%)
Uncert:    +/-0.0307      +/-0.0268 TPU:      +/-0.0307      +/-0.0268 liobium-94                                    U      0.0126  U    0.0123      pCi/g      3      (0% -100%)
Uncert:      +/-0.026      +/-0.0256 TPU:        +/-0.026      +/-0.0256 otassium-40                                              25.6          24.1    pCi/g      6        (0%  -20%)
Uncert:        +/-2.07        +/-1.82 TPU:          +/-2.07        +/-1.82
,adium-226                                                1.72            1.65    pCi/g      4      (0%  -100%)
Uncert:      +/-0.201        +/-0.195 TPU:        +/-0.201        +/-0. 195 liver-I 08m                                  U  -0.00652    U    -0.0062      pCi/g      5      (0% -100%)
Uncert:    +/-0.0249      +/-0.0235 Page 112 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:      183243                                                                                      Page 4 of 13 arnmame                              NOM          Sample Qual          QC    Units__RPD%      REC%_    Range    AnIst  Date  Time ad Gamma Spec itch          621149 TPU:  +/-0.0249      +/-0.0235 hallium-208                                            0.564            0.506    pCilg    I1I          (0%  -20%)
Uncert:  +/-0.0846      +/-0.0705 TPU:  +/-0.0846      +/-0.0705 LCS
,ctinium-228                                                              1.50    pCilg                                  04/03/07 13:00 Uncert:                    +1-0.705 TPU:                    +1-0.705
'mericium-241                          16.0                              14.2    pCilg            89 (75%-125%)
Uncert:                      +/-1.49 TPU:                      +/-1.49
;ismuth-2 12                                                  U        0.645    pCi/g Uncert:                    +1-0.763 TPU:                    +1-0.763
;ismuth-2 14                                                            0.697    pCi/g Uncert:                    +/-0.253 TPU:                    +/-0.253
.esium- 134                                                  U      0.0839      pCi/g Uncert:                    +/-0.105 TPU:                    +/-0.105 lesium- 137                          6.20                              5.80    pCilg            94 (75%-125%)
Uncert:                    +/-0.571 TPU:                  +/-0.571
.obalt-6                              9.32                              9.36    pCilg            100 (75%-125%)
Uncert:                    +1-0.701 TPU:                    +1-0.701
,uropium- 152                                                U      -0.176      pCilg Uncert:                    +/-0.243 TPU:                    +1-0.243
.uropium-1 54                                                U      0.00147      pCilg Uncert:                    +/-0.242 TPU:                    +/-0.242
,uropium-155                                                  U        0.0771    pCilg Uncert:                    +/-0.250 TPU:                    +/-0.250
*ead-212                                                                0.907    pCilg Uncert:                    +/-0.176 TPU.                    +1-0.176
,ead-214                                                                0.454    pCi/g Uncert:                    +1-0. 23 8 TPU:                    +/-0.238 langanese-54                                                  U        0.0229    pCilg Uncert:                  +/-0.0932 TPU:                  +/-0.0932 liobium-94                                                    U      -0.0465      pCi/g Uncert:                    +/-0.084 TPU:                    +1-0.084 otassium-40                                                  U        0.383    pCilg Page 113 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171 - www.gel.com OC Summary Vorkorder:      183243                                                                                      Page 5 of 13 armname                              NOM          Sample Qpal          OC      Units    RPD%    REC%      Ranae    AnIst  Date Time ad Gammia Spec itch          621149 Uncert:                    +/-0.835 TPU:                      +/-0.835
.adium-226                                                              0.697        pCilg                (75%-1 25%)
Uncert:                    +/-0.253 TPU:                      +/-0.253 ilver-1 08m                                                  U      -0.0512        pCilg Uncert:                    +/-0.0813 TPU:                    +/-0.0813 ballium-208                                                            0.328        pCilg Uncert:                      +1-0.152 TPU:                      +/-0.152 MB
,ctinium-228                                                  U    -0.00165          pCilg                                  04/03/07 12:57 Uncert:                    +/-0.0486 TPU:                    +/-0.0486
,mericium-241                                                U        0.0179        pCilg Uncert:                    +/-0.0243 TPU:                    +/-0.0243
;ismuth-21 2                                                  U      -0.0577        pCilg Uncert:                      +/-0.1 10 TPU:                      +/-0.110
;ismuth-214                                                  U        0.0128        pCilg Uncert:                    +/-0.0306 TPU:                    +/-0.0306
.esium- 134                                                  U      0.00507        pCilg Uncert:                  +/-0.0126 TPU:                    +/-0.0126
.esium- 137                                                  U      0.00189        pCilg Uncert:                    +/-0.012 TPU:                      +1-0.012
'obalt-60                                                    U      0.00173        pCilg Uncert:                  +1-0.0135 TPU:                    +1-0.0135
.uropium- 152                                                U      0.00881        pCilg Uncert:                  +/-0.0314 TPU:                    +/-0.0314
,uropium- 154                                                U      -0.0162        pCilg Uncert:                    +/-0.040 TPU:                      +/-0.040
.uropiumn-155                                                U        0.0195        pCilg Uncert:                    +/-0.032 TPU:                      +/-0.032
.ead-21 2                                                    U      -0.0286        pCilg Uncert:                  +/-0.0274 TPU:                    +/-0.0274
.ead-214                                                      U      -0.01 56        pCilg Uncert:                  +1-0.0217 TPU:                    +/-0.0217 Page 114 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:      183243                                                                                    Page 6 of 13 armname                                NOM_        SampleQua]          QC    Units    RPD%    REC%      Range  AnIst  Date Time ad Gamma Spec itch          621149 langanese-54                                                  U    0.00042      pCi/g Uncert:                    +/-0.0108 TPU:                    +/-0.0108 liobium-94                                                    U  -0.00626      pCi/g Uncert:                    +/-0.012 TPU:                      +/-0.01 2 otassium-40                                                    U      0.200    pCi/g Uncert:                    +/-0.186 TPU:                      +/-0.186
.adium-226                                                      U      0.0128    pCi/g Uncert:                    +/-0.0306 TPU:                    +/-0.0306 ilver- 108m                                                    U -0.000226      pCi/g Uncert:                    +/-0.01 11 TPIJ:                    +/-0.0111
'hallium-208                                                    U -0.000331      pCi/g Uncert:                    +/-0.0177 TPU:                    +/-0.0177 itch          621152 183243001 DUP
,ctinium-228                                              1.13            1.20    pCi/g      5        (0% - 100%) MJHJ  04/03/07 19:24 Uncert:    +/-0.237        +/-0.196 TPU:      +/-0.237        +/-0.196
,mericium-241                                  U    -0.0022    U      0.0326    pCi/g    229        (0% -100%)
Uncert:    +/-0.0988      +/-0.0574 TPU:    +/-0.0988      +/-0.0574
;ismuth-2 12                                              1.09          0.920    pCi/g    17        (0% -100%)
Uncert:    +/-0.345        +/-0.274 TPU:      +/-0.345        +/-0.274
;ismuth-2 14                                              1.09            1.16    pCi/g      6          (0% -20%)
Uncert:    +/-0.145        +/-0.129 TPU:      +/-0.145        +/-0.129 esium- 134                                    U      0.0454  Ul        0.00    pCi/g    53        (0% -100%)
Uncert:    +/-0.0666      +/-0.02 15 TPU:    +/-0.0666      +/-0.02 15 esium- 137                                            0.256          0.241    pCi/g      6        (0% -100%)
Uncert:    +/-0.0555      +/-0.0301 TPU:    +1-0.0555      +/-0.0301 obalt-60                                      U      0.0348  U      0.0179      pCi/g    64        (0% -100%)
Uncert:    +/-0.0451      +/-0.0227 TPU:    +/-0.0451      +/-0.0227
.uropium- 152                                  U      0.0544  U    0.00878      pCi/g    144        (0% -100%)
Uncert:    +/-0.103      +/-0.0479 TPU:      +/-0.103      +/-0.0479
.uropium- 154                                  U      0.0802  U    -0.0305      pCi/g  446        (0% -100%)
Uncert:    +/-0.0857      +/-0.0507 TPU:    +/-0.0857      +/-0.0507
,uropium-155                                  U      0.0543  U      0.037      pCi/g    38        (0% -100%)
Page 115 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171  -  www.gel.com QC Summary Vorkorder:      183243                                                                                          Page 7 of 13 armname                              NOM            Sample Qual        QC      Units    RPD%      REC%      Range  Artist  Date  Time ad Gamma Spec itch          621152 Uncert:    +/-0.0742      +/-0.0415 TPU:    +/-0.0742      +/-0.0415 ead-21 2                                                  1.25          1.24        pCi/g      0          (0%  -20%)
Uncert:      +/-0.121      +/-0.106 TPU:      +/-0.121      +/-0.106
,ead-214                                                  1.34          1.27        pCi/g      6          (0%  -20%)
Uncert:      +/-0.161      +/-0.123 TPU:      +/-0.161      +/-0.123 langanese-54                                    u    -0.0131  U  0.000953          pCi/g    231          (0%  -100%)
Uncert:    +/-0.0311        +1-0.015 TPU:    +/-0.031 1      +1-0.015
[iobium-94                                      u    0.00411  U        0.014        pCi/g    109          (0%  -100%)
Uncert:    +/-0.028 1    +/-0.0145 TPU:    +/-0.0281      +1-0.0145 otassium-40                                              18.0          18.3        pCi/g      2          (0%  -20%)
Uncert:      +1-1.49        +/-1.24 TPU:      +1-1.49        +/-1.24
.adium-226                                                1.09          1.16        pCi/g      6          (0%  -100%)
Uncert:      +1-0.145      +/-0.129 TPU:      +/-0.145      +/-0.129 ilver-1I08m                                    U  -0.00485  U  -0.00602          pCi/g      22          (0%  -100%)
Uncert:      +/-0.024    +/-0.0132 TPU:      +/-0.024    +/-0.0132 ballium-208                                              0.363          0.362        pCi/g      0          (0%  -100%)
Uncert:    +/-0.0601      +/-0.0447 TPU:    +/-0.0601      +/-0.0447 QC1201305356      LCS
.ctinium-228                                                            1.10        pCilg                                    04/03/07 14:24 Uncert:                    +/-0.589 TPU:                    +/-0.589
,mericium-241                          16.0                              14.5        pCi/g              91 (75%-125%)
Uncert:                      +/-2.17 TPU:                      +/-2.17
;ismuth-2 12                                                  U        0.849        pCi/g Uncert:                    +/-0.831 TPU:                    +/-0.831
;ismuth-2 14                                                            0.784        pCi/g Uncert:                    +/-0.293 TPU:                    +/-0.293
,esium- 134                                                  U        0.123        pCi/g Uncert:                    +/-0.114 TPU:                    +/-0.114
,esium- 137                            6.20                              5.88        pCi/g              95 (75%-125%)
Uncert:                    +/-0.518 TPU:                    +/-0.518
'obalt-60                            9.32                              9.25        pCi/g              99 (75%-125%)
Uncert:                    +/-0.705 TPU:                    +/-0. 705 Page 116 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171  - www.gel.com QC Summary Vorkorder:      183243                                                                                        Page 8 of 13 armname                              NOM          Sample Qual          QC        Units    RPD%    REC% __Range      Anlst _DateTime ad Gamma Spec Atch          621152
,uropium- 152                                                U        0.128        pCi/g Uncert:                    +/-0.3 12 TPU:                    +/-0.312
,uropium- 154                                                U        0.206        pCi/g Uncert:                    +1-0.285 TPU:                    +/-0.285
,uropium-155                                                  U        -0.14        pCilg Uncert:                    +/-0.293 TPU:                    +1-0.293
,ead-21 2                                                              0.835        pCilg Uncert:                    +/-0.232 TPU:                    +/-0.232
,ead-21 4                                                                1.03        pCi/g Uncert:                    +/-0.352 TPU:                    +1-0.352 langanese-54                                                  U      0.0289        pCi/g Uncert:                    +/-0.103 TPU:                    +1-0.103 liobium-94                                                    U        0.022        pCilg Uncert:                    +/-0.106 TPU:                    +1-0. 106 otassium-40                                                  U        0.272        pCi/g Uncert:                    +1-0.992 TPU:                    +1-0.992
.adium-226                                                            0.784        pCilg                (75%-125%)
Uncert:                      +/-0.293 TPU:                      +/-0.293 ilver- 1Om                                                    U    -0.0421          pCilg Uncert:                      +/-0.086 TPU:                      +/-0.086
'hallium-208                                                          0.387        pCilg Uncert:                      +/-0.196 TPU:                      +1-0.196 QC1201305354      MB U      0.0135        pCilg                                    04/03/07 19:22
,ctinium-228 Uncert:                      +/-0. 043 TPU:                    +/-0.043
,mericium-241                                                U      0.0143        pCilg Uncert:                    +1-0.0304 TPU:                    +1-0.0304
;ismuth-2 12                                                  U      0.0396        pCilg Uncert:                    +1-0.0567 TPU:                    +1-0.0567
;ismuth-214                                                  U      0.0047        pCilg Uncert:                    +/-0.023 8 TPU:                    +1-0.0238
.esium- 134                                                  U    0.00123          pCilg Uncert:                  +/-0.00762 Page 117 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407      - (843) 556-8171  - www.gel.com QC Summary Vorkorder:      183243                                                                                          Page 9 of 13 armname                              NOM          Sample Qual          QC      Units    RPD%    REC%      Range  Anist  Date  Time ad Gammua Spec itch          621152 TPU:                  +/-0.00762
.esium- 137                                                  U      0.00264          pCi/g Uncert:                    +/-0.0074 TPU:                    +/-0.0074
,obalt-60                                                    *  -0.000251            pCilg Uncert:                  +/-0.00725 TPU:                  +/-0.00725
,uropium-152                                                  U    -0.00829            pCilg Uncert:                    +1-0.0177 TPU:                    +1-0.0177
,uropium- 154                                                U      0.00151          pCilg Uncert:                    +/-0.0211 TPU:                    +/-0.0211
,uropiun-155                                                  U    -0.00241          pCilg Uncert:                    +/-0.0178 TPU:                    +/-0.0178
,ead-212                                                      U      -0.0257          pCilg Uncert:                    +/-0.0206 TPU:                    +/-0.0206
,ead-214                                                      U        0.0229          pCilg Uncert:                    +/-0.0222 TPU:                    +/-0.0222 langanese-54                                                  U    -0.00111          pCilg Uncert:                  +/-0.00691 TPU:                  +1-0.00691 Tiobium-94                                                    U    0.000744          pCilg Uncert:                  +/-0.00807 TPU:                  +1-0.00807 otassiumn-40                                                  U      0.00403          pCilg Uncert:                      +/-0. 137 TPU:                      +/-0.137
.adium-226                                                  U        0.0047        pCilg Uncert:                    +/-0.0238 TPU:                    +/-0.0238 ilver- I 08m                                                  U    0.000961          pCilg Uncert:                    +/-0.0063 TPU:                    +1-0.0063 ballium-208                                                  UI          0.00        pCilg Uncert:                    +1-0.0181 TPU:                    +1-0.0181 ad Gas Flow itch          621125 QC1201305282  183245021 DUP trontium-90                                    U    -0.0124  U          0.013        pCi/g      0          (0%-100%) NXL3  04/03/07 17:11 Uncert:    +/-0.0237      +/-0.0268 TPU:    +/-0.0237      +/-0.0268 QC1201305284      LCS trontiuni-90                          1.40                                1.38        pCi/g              99 (75%-125%)      04/03/07 17:53 Page 118 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171  - www.gel.com QC Summary Vorkorder:        183243                                                                                            Page 10 of 13 armname                                  NOM            Sample Qual        QC_      Units    RPD%    REC%      Range  -Anist _Date Time ad Gas Flow itch            621125 Uncert:                  +/-0.0937 TPU:                    +/-0.103 QC1201305281        MB trontium-90                                                      U  -0.00552          pCi/g                                    04/03/07 17:11 Uncert:                  +1-0.0133 TPU:                  +1-0.0133 QC1201305283      183245021 MIS trontium-90                              1.41      U    -0.0124            1.17        pCi/g              83 (75%-125%)        04/03/07 17:11 Uncert:    +/-0.0237      +/-0.127 TPU:    +/-0.023 7      +/-0.132 itch          621126 QC1201305286      183243014 DUP trontium-90                                        U      0.0275 U      0.0138          pCi/g      0          (0% - 100%) NXL3  04/02/07 20:52 Uncert:      +/-0.020    +/-0.0222 TPU:      +/-0.020    +/-0.0222 QC1201305288        LCS trontium-90                              1.43                              1.45        pCi/g            102 (75%-125%)        04/02/07 20:52 Uncert:                    +/-0.099 TPU:                    +/-0.1 04 QC1201305285        MB trontium-90                                                      U  -0.00764          pCi/g                                    04/02/07 20:51 Uncert:                  +/-0.0133 TPU:                  +/-0.0133 QC1201305287      183243014 MS trontium-90                              1.63      U      0.0275            1.62        pCi/g              99 (75%-125%)        04/02/07 20:52 Uncert:      +/-0.020      +/-0.123 TPU:      +/-0.020      +/-0.129 ad Liquid Scintillation itch          621136 QC1201305301      183245006 DUP
-on-55                                              U      -26.4 U          2.65        pCi/g      0          (0% - 100%) A4XP1I 04/02/07 22:19 Uncert:        +/-34.3      +/- 34. 0 TPU:        +/-34.3      +/-34.0 QC 1201305303        LCS
  -on-55                                  1180                              1130        pCi/g              96 (75%-125%)        04/02/07 22:51 Uncert:                      +/-6 1.3 TPU:                      +/-98.0 QC1201 305300        MB
*on-55                                                            U        -26.4        pCi/g                                    04/02/07 22:02 Uncert:                      +/-28.2 TPU:                    +/-28.2 QC1201305302      183245006 MS
  -on-55                                  1230      U      -26.4            1180        pCi/g              96 (75%-125%)        04/02/07 22:35 Uncert:        +/-34.3        +/-69.4 TPU:      +/-34.3        +/-110 itch          621137 QC1201305305      183245006 DUP
[ickel-63                                          U      -11.2 U        -8.44        pCi/g      0          (0%  - 100%) VlXPI 04/02/07 17:27 Page 119 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171  - www.gel.com QC Summary Vorkorder:        183243                                                                                          Page I1I of 13 armname                                  NOM            Samo~le Onal      QC      Units    RPD%    REC%      Range    Anst    Dae      im ad Liquid Scintillation itch          621137 Uncert:      +/-9.41      +/-10.1 TPU:      +/-9.41      +/-10.1 QC1201305307        LCS
[ickel-63                                  556                              477        pCilg              86 (75%-125%)          04/02/07 17:59 Uncert:                    +/-25.4 TPU:                    +/-30.6 QC1201305304        MB fickel-63                                                        U        2.75        pCilg                                    04/02/07 17:10 Uncert:                    +1-11.6 TPU:                    +/-11.6 QC1201305306      183245006 MIS
[ickel-63                                  591      U    -11.2            505        pCilg              85 (75%-125%)          04/02/07 17:43 Uncert:      +/-9.41      +/-27.3 TPU:      +/-9.4 1      +/-33 .0 itch            621139 QC1201305311      183245006 DUP echnetium-99                                        U    -0.155  U    -0.139        pCi/g      0          (0% - 100%) OAXP I  04/03/07 15:56 Uncert:    +/-0.229      +/-0.236 TPU:      +/-0.229      +/-0.236 QC1201305313        LCS echnetium-99                              19.6                            16.4        pCilg              84 (75%-125%)          04/03/07 17:00 Uncert:                  +/-0.466 TPU:                    +/-0.623 QC1201305310        MB echnetium-99                                                      U    -0.281        pCilg                                    04/03/07 15:25 Uncert:                  +/-0.210 TPU:                  +/-0.210 QC1201305312      183245006 MIS
'echnetium-99                            20.0      U    -0.155          15.0        pCilg              75 (75%-125%)          04/05/07 09:59 Uncert:    +/-0.229      +/-0.676 TPU:    +/-0.229      +/-0.776 itch            621141 QC1201305317      183255002 DUP
'ritium                                              U    -0.106  U      0.451        pCilg      0          (0%- 100%) kXD2    03/31/07 18:55 Unicert:    +1-1.06      +1-1.03 TPU:      +/-1.06      +/-1.03 QC1201305319        LCS
'ritium                                  11.7                            12.0        pCi/g            102 (75%-125%)          03/31/07 20:57 Uncert:                    +/-1.54 TPU:                    +1-1.55 QC1201305316        MB
'ritium                                                          U    -0.232        pCilg                                    03/31/07 17:53 Uncert:                  +/-0.991 TPU:                  +/-0.991 QC1201305318      183255002 MIS
'ritium                                  11.9      U    -0.106          13.2        pCi/g            111 (75%-125%)          03/31/07 19:56 Uncert:      +/-1.06      +/-1.63 TPU:      +1-1.06      +/-1.65 itch            621144 Page 120 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Vorkorder:        183243                                                                                                Page 12 of 13 armname                                        NOM            Sample Qua)          OC      Units    RPD%  REC %    Ran-ae  Anist    Date Time ad Liquid Scintillation itch          621144 QC1201305325 183245006 DUP
.arbon-14                                                    U  0.0236  U      -0.0162          pCi/g      0      (0%- 100%) A~XD2  04/02/07 15:22 Uncert:      +/-0.090        +/-0.0934 TPU:      +/-0.090        +/-0.0934 QC1201305327        LCS
'arbon-14                                      7.09                                  7.02        pCi/g          99 (75%-125%)        04/02/07 17:28 Uncert:                        +/-0.203 TPU:                        +/-0.231 QC1201305324        MB
'arbon-14                                                                U      -0.0233          pCi/g                                04/02/07 14:19 Uncert:                      +/-0.0925 TPU:                      +/-0.0925 QC1201305326      183245006 MS
.arbon-14                                      7.16      U      0.0236              6.92        pCi/g          97 (75%-125%)        04/02/07 16:25 Uncert:      +/-0.090        +/-0.202 TPU:      +/-0.090        +1-0. 229
.N/otes:
rhe Qualifiers in this report are defined as follows:
  **    Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A    The TIC is a suspected aldol -condensation product B    For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD    Results are either below the MDC or tracer recovery is low C    Analyte has been confirmed by GC/MS analysis D    Results are reported from a diluted aliquot of the sample H    Analytical holding time was exceeded J    Value is estimated N/A  Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND    Analyte concentration is not detected above the detection limit R    Sample results are rejected U    Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI    Gamma Spectroscopy--Uncertain identification X    Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y    QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h    Preparation or preservation holding time was exceeded Page 121 of 122
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171              - www.gel.com QC Summary Vorkorder:        183243                                                                                                            Page 13 of 13 armname                                        NOM              Sample Qual            QC      Units RPD%          REC%          Range AnIst    Date Time JIA indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.
* Indicates analyte is a surrogate compound.
The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the ample is greater than      five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is
-ss than 5X the RL, a control limit of +/- the    RL is used to evaluate the DUP result.
*or PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Vhere the analytical method has been performed under NELAP certification, the analysis has met all of the
-quirements of the NELAC standard unless qualified on the QC Summary.
Page 122 of 122
 
Ge-n-e--ralI Narrative Page 1 of 28
 
General Narrative for Connecticut Yankee Atomic Power Co.
Work Order: 183321 SDG: MSR#07-0134 April 04, 2007 Laboratory Identification:
GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at GEL Laboratories LLC, Charleston, South Carolina on March 30, 2007 for analysis.
Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.
Sample Identification The laboratory received the following samples:
Laboratory          Sample Identification      Description 183321001          9312-0010-124-1 183321002          9312-0010-125-1 183321003          9312-0010-126-1 Items of Note There are no items to note.
Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.
Analytical Request Three soil samples were analyzed for FSSGAM and Strontium-90.
Data Package-The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl      &#xfd;Jones Project Manager GEL Laboratories Pfige 2P&MB0071 2 Charleson, SC 29417      2040 Savage Road Charleston SC 29407 P843.556.8171 F B43758.1178 www.goI.com
 
List of current GEL Certifications as of 04 April 2007 State                      Certification Alaska                        UST-062 Arizona                        AZ0668 Arkansas                        88-0651 CLIA                        42DO904046 California                      0115]ICA Colorado                      GenEngLabs Connecticut                      PH-01 69 Dept. of Navy                    NFESC 413 EPA                          WG-15J FloridaINELAP                      E87 156 Georgia                  E87 156 (FL/NELAP)
Hawaii                            N/A Idaho                            N/A Illinois                        200029 Indiana                        C-SC-01 Kansas                        E-10332 Kentucky                          90129 Louisiana                        03046 Maryland                            270 Massachusetts                    M-SCOI 2 Michigan                            9903 Nevada                            SC12 New Jersey                        SCO02 New Mexico                    FL NELAP E87 156 New York                          11501 North Carolina                        233 North Carolina Drinking W                  45709 North Dakota                        R-158 Oklahoma                            9904 Pennsylvania                      68-00485 South Carolina            10120001/10585001/10120002 Tennessee                          02934 Texas                      TX21 3-2006A Texas NELAP                  T]04704235-06-TX U.S. Dept. of Agriculture                S-52597 US Army Corps of Engineer                    N/A Utah                    8037697376 GEL Vermont                        VT87156 Virginia                          00151 Washington                        C1641 Page 3 of 28
 
Chain of Custody and Supporting Documentation Page 4 of 28
 
Connecticut Yankee Atomic Power Company                                                                      Chain of Custody Form                          N.20-00 362 Injun Hollow Road, East Hampton, CT 06424                                                                                                  N.20-00 860-267-2556_____
Project Name: Hladdam Neck Decommissioning                                                                    Analyses Requested          Lab Use Only Contact Name & Phone:                                                                                                                      Comments:
Jack McCarthy 860-267-3924                                    Media  Sample  Container
_________________________________                Code    Type      Size-Analytical Lab (Namre, City, State):                                    Code    &Type General Engineering Laboratories                                                Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-8171)                                                                -
Priority: Li 30 D. Li 15        D. E 7 D.
Other:                                                                                                                                    __________                ________
Sample Designation                      Date        Time                                                                                    Comment. Preservation      Lab Sample ID 9312-0010-124-1                      3/29/07          0715      IS      G        BP            X___
9312-00t:0-125-1                    3/29/07          0717      IS      G        BP            X      __                              __
93 12-0010-126-1                    3/29/07          0720    IS        G        BP          X___                                        _________________
NOTES: P0O# 002332                          MSR #:07-0 134          Z  LIP QA              Fi Radwaste QA                Li  Non QA    Samples Shipped Via:        Internal Container 0 Fed Ex                  Temp.:    f~Deg. C El UPS
__________________________________                F_1  Hand                  Custody Sealed?
: 1) Relinq~          '                                Date/Time        2) Received By                                      Date/Time      ElOhrCustody                        Seal Intact?
                                                                    ,14f/#7~L                              Y1Other-              :,3
: 3) RelinquishedyBy                                  Date/Time        4) Received By                                      Date/Time      ___________YV2                        No I                                                  Bill of Lading #
: 5) Relinquished By                                  Date/Time        6) Received By                                      Date/Time
 
Connecticut Yankee Statement of Work for Analytical Lab Services                                                -CY-ISC-SOW-O0l Figure I. Sam      Chc-inLit          -    >
Datetfflme Received..                                    0.3J -3O0 SDGII:                                                                t
    'Work Order Number:              V          3 212 1        3 zJ Shipping Cchtainer ID:. 2-iaE52&#xfd;0 ' t173 chain of Custody N                    0cCg7      (-MC(X&#xfd;c5 ~&I I.        Custdy Seals.od Shiping container intactT -                          Yes VfNo      [
: 2.        Custody Scals dated and signed?                                      Yes I-(No        I---
: 3.        Chain-of-Custo-Jy record present?                                  Yes fA[
  .4.        Cooler temperature      U
: 5.        .Venmiculitelpacking mnaterials is:                                  Y et  (IDry 6:.        -Numberofsamp)les inishipping container.              3  C&#xfd;Ad~
: 7.        Sample holding times exceeded?                                      Yes    [I No &J"
      .8.. Sample have.
                      -                            -hazard      labels
_-L-ustoy sels                        appropriate sample labels
: 9. Samples are:
gooducondtion                    l._eaking
_- broken                            -- have,air bubbles
: 10.        Were any anomalies    ridentfied in sample receipt?                Ye[JN4J
      ~. Descriptio of anoualiek(inlud sample numbers):
Samnple CuodfiaWLakoratry.          T                                        D1.30~&~)
Telephoned to:-nB Page 6 of 28
 
LU          r    SAMPLE RECEIPT & REVIEW FORM IPM use only Client:          C (jp)(        L~j-t- A
                                  )jc_      t\      e        SDGIARCOC/Work Order:/33                          2,1          3  /
Date Received:                    3        co3                PM(A) Review (ensure non-conif                g itm re resolved prior to signing):
Received By:
Sample Receipt Criteria                      0          Comments/Qualifiers (Required for Non-Conforming Items) ircle Applicable: seals broken  damaged container *aking container "'6ther (desribe)
IShipping 1intact      andcontainers received sealed?______________________________
ISamples requiring cold                                  Circle Coolant #      ice bags      blue ice        dry ice      none    (oted~r 2 preservation within (4 +1- 2 C)?                      /
Record preservation method.                                      & e                c-3Chain of custody documents included with shipment?                    --            iceApial:sasboe                  aae      otie      ekn    otie      iir(ecie 4 Sample containers intact andCiceApial:sasboedaaecotielekncotierthr(srb) sealed?__________________________
5    Smlsrqiigchemical                                      Sample 113s. containers affected and observed pH:
  -preservation        at proper pH?-
6VOA vials free ojf headspace                              Sample ID's and containers affected:
6(defined as < 6mm bubble)?____________                                                                    _____________
7 jAre (If yes, Encore containers present?
immediately detiver to                V VOA laboratory)__________________                                                                                          _______
Samples received within holding                        Id's and tests affected:
8time?                                                      _      _        _      _      _      _      _      _      _    _      _      _
9Sample ID's on COC match ID's                            ample ID's. and containers affected:
on bottles?                                            __________________________
Samplje IJ's affected:
WDate & time on COG match date 10& time on bottles?                                        ___________________________
Smple ID's affecred:
11Number of containers received Imatch number indicated on COC?
COC form is properly signed in 12 relinquished/received sections?                            __7 __1___09___El_____________(o______7__
14 Additional Comments
                                                        ~~  ~RSO RAD Receipt#                    ___________
                                                              ~*If > x2 area background is observed on samples identified as "non-Suspected~
HaadIn1mtin    ~        :            regulated/nion-radioactive", contact the Radiation Safety group for further Siinvestigation.
rA Radiological Classification?                                Maximum Counts Observe&*:                                  n B PCB Regulate-d?                                YV Shipped as WOT Hazardous C Material? If yes, contact Waste                                aadCssSied Manager or ESH Manager.                              U#
DRegula.ted As a Foreign Soil?!
IN;or AAreview of Hazard classification:                          Initials        7r                Date:      ~
 
Data Review Qualifier Definitions Page 8 of 28
 
Data Review Qualifier DefinitionB Qualifier          Explanation
* A quality control analyte recovery is outside of specified acceptance criteria
              **  Analyte is a surrogate compound
          <        Result is less than value reported
          >        Result is greater than value reported ARPD      of sample and duplicate evaluated using +/-RL. Concentrations are cSX the RL A        The TIC is a suspected aldol-condensation product B        Target analyte was detected in the associated blank B        Metals-Either presence of analyte detected in the associated blank, or MDL/IDL <  sample value < PQL BD      Results are either below the MDC or tracer recovery is low C        Analyte has been confirmed by CC/MS analysis D        Results are reported from a diluted aliquot of the sample d        5-day BOD-The 2:1 depletion requirement was not met for this sample E        Organics-Concentration of the target analyte exceeds the instrument calibration range E      Metals-idifference of sample and SD is >10t.              Sample concentration must meet flagging criteria H        Analytical holding time was exceeded h        Preparation or preservation holding time was exceeded J        Value is estimated N        Metals-The Matrix spike      sample recovery      is not within specified control limits N        Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte          (TIC) . Quantitation is based on nearest internal standard response factor N/A      Spike recovery limits do not apply.            Sample concentration exceeds spike concentration by 4X or more ND        Anelyte concentration is not detected above the reporting limit UT        Gamma Spectroscopy-Uncertain identification X        Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y        QC Samples were not spiked with this compound Z        Paint Filter Test-Particulates passed through the filter,            however no free liquids were observed.
GEL Laboratories Pfige 9RP~c~712      Charleston. SC 29417    2040 Savage Road ChaulestonSC 29407  P843.555.171 F843.755.1178  www.goI.coiU
 
RADIOLOGICAL ANALYSIS Page 10 of 28
 
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 183321 Method/Analysis Information Product:                      Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:            EML HASL 300, 4.5.2.3 Prep Method:                  Dry Soil Prep Analytical Batch Number:      622281 Prep Batch Number:            621413 Sample ID      Client ID 183321001      9312-0010-124-1 183321002      9312-0010-125-1 183321003      9312-0010-126-1 1201307871      Method Blank (MB) 1201307872      183322021(9306-0000-01 9B) Sample Duplicate (DUP) 1201307873      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 13 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Oualitv Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Page 11I of 28
 
Designated QC The following sample was used for QC: 183322021 (9306-O000-019B).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Qualifier                    Reason                      Analyte        Sample U'            Data rejected due to low abundance. Cesium- 134      183321001 U'            Data rejected due to no valid peak.      Americium-241    183321001 Method/Analysis Information Page 12 of 28
 
Product:                                          Product:GFPC, Sr9O, solid-ALL FSS Analytical Method:                                EPA 905.0 Modified Prep Method:                                      Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:                Dry Soil Prep Analytical Batch Number:                          621435 Prep Batch Number:                                621414 Dry Soil Prep GL-RAD-A-021 Batch Number:          621413 Sample ID      Client ID 183321001      9312-0010-124-1 183321002      9312-0010-125-1 183321003      9312-0010-126-1 1201305974      Method Blank (MB) 1201305975      183322004(9306-0000-004F) Sample Duplicate (DUP) 1201305976      183322004(9306-0000-004F) Matrix Spike (MS) 1201305977      Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 11.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Oualitv Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 183322004 (9306-0000-004F).
QC Information All of the QC samples met the required acceptance limits.
Page 13 of 28
 
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prepfRe-analysis Sample 183321003 (93 12-0010-126-1) was recounted due to a detector lock out condition.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.
The following data validator verified the information presented in this case narrative:
Reviewer/Date:                      11&#xfd;        &#xfd;4            415/6 Page 14 of 28
 
SAMPLE DATA
 
==SUMMARY==
 
Page 15 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOOlI Connecticut Yankee Atomnic Power Co.
Client SDG: MSR#07-O 134 GEL Work Order: 183321 The Qualifiers in this report are defined as follows:
  *A  quality control analyte recovery is outside of specified acceptance criteria
    **Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UL Gamma Spectroscopy--Uncertain identification ND    The analyte concentration is not detected above the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by Page 16 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171      -  www.gel.com Certificate of Analysis Company :Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                      Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                  93 12-0010-124-1                  Project:        YANK01204 Sample ID:                        183321001                        Client ID:        YANKO0l Matrix:                            TS                                Vol. Recv.:
Collect Date:                      29-MAR-07 Receive Date:                      30-MAR-07 Collector:                        Client Moisture:                          5.01%
Parameter                  Qualifier  Result  Uncertainty        LC    TPU        MDA          Units          DF Analyst Date      Time Batch A~
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            1.55    +/-0.303  0.0947  +/-0.303      0.189          pCilg              MJIi 04/03/07 1754 622281 Americium-241                  UI      0.00    +/-0.165  0.0952  +/-0.165      0.190          pCi/g Bismuth-2 12                          0.934    +/-0.393    0.202  +/-0.393      0.404          pCilg Bismuth-214                              1.83    +/-0.220  0.0519  +/-0.220      0.104          pCilg Cesium-134                      UI      0.00  +/-0.0452    0.0331  +/-0.0452    0.0662          pCilg Cesium-137                            0.163  +/-0.0526    0.0261  +/-0.0526    0.0521          pCi/g Cobalt-60                        U    0.0195    +/-0.0338  0.0292  +/-0.0338    0.0583          pCilg Europium-152                    U -0.0563      +/-0.118  0.0757  +/-0.118      0.151          pCilg Europium-154                    U -0.0255      +/-0.116  0.0803  +/-0.116      0.161          pCi/g Europium-ISS                    U    0.0372    +/-0.105    0.092  +/-0.105      0.184          pCi/g Lead-212                                1.53    +/-0.156  0.0466  +/-0.156    0.0931          pCi/g Lead-214                                2.18    +/-0.244  0.0556  +/-0.244      0.111          pCi/g Manganese-54                    U  -0.029    +/-0.0315  0.0255  +/-0.0315    0.0509          pCi/g Niobium-94                      U    0.028    +/-0.0296  0.0257  +/-0.0296    0.0513          pCi/g Potassium-40                            27.1      +/-2.14    0.237    +/-2.14    0.473          pCi/g Radium-226                              1.83    +/-0.220  0.0519  +/-0.220      0.104          pCi/g Silver-108m                      U    0.0285    +1-0.0301  0.0267  +/-0.0301    0.0534          pCi/g Thallium-208                          0.540  +/-0.0804      0.028 +/-0.0804      0.056          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, so/id-ALL FSS Strontium-90                    U    0.0199    +/-0.0276  0.0206 +/-0.0276      0.0474          pCi/g              KSD1    04/04/07 1305 621435 The following Prep Methods were performed Method              Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep      Dry Soil Prep GL-RAD-A-021                            JMBI          03/30/07          1052    621413 The following Analytical Methods were performed Method            Description I~            EMIL HASL 300,4.5.2.3 2                  EPA 905.0 Modified Page 17 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Analysis Company:      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                                Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  9312-0010-124-I              Project:      YANK01204 Sample ID:                          183321001                    Client ID: YANKO0l Vol. Recv.:
Parameter                  Quallifier  Result    Uncertainty    [C    TPU      XMA          Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery        Test                                Recovery%        Acceptable Limits Strontium Carrier                  GFPC, Sr90, solid-ALL FSS                78            (25%-I125%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greaterthan value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCJMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit
* Sample results are rejected
* Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 18 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    -  (843) 556-8171    - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils P04* 002332 Client Sample ID:                  9312-0010-125-I                  Project:        YANKO 1204 Sample ID:                          183321002                        Client ID: YANKOO I Matrix:                            TS                                Vol. Recv.:
Collect Date:                      29-MAR-07 Receive Date:                      30-MAR-07 Collector:                          Client Moisture:                          7.69%
Parameter                    Qualifier    Result  Uncertainty        LC      TPU        MDA          Units        DF Analyst Date      Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228                            0.872    +/-0.213    0.0753  +/-0.213      0.151        pCi/g              MJHI 04/03/07 2159 622281 Americium-241                      U    0.0781  +/-0.0976    0.0835  +/-0.0976      0.167        pCi/g Bismuth-212                              0.653    +/-0.315      0.172  +/-0.315      0.343          pCi/g Bismuth-214                              0.927    +/-0.142    0.0436  +/-0.142    0.0871          pCi/g Cesium-134                        U    0.0388    +/-0.0451    0.0295  +/-0.0451    0.0591          pCilg Cesium-137                              0.354    +/-0.0678    0.0257  +/-0.0678    0.0515          pCi/g Cobalt-60                          U    0.0148    +/-0.0261    0.0227  +/-0.0261    0.0454          pCi/g Europium-152                      U    0.0365    +/-0.099    0.0633  +/-0.099      0.127          pCi/g Europium-154                      U -0.0775      +/-0.0991    0.0631  +1-0.0991      0.126          pCi/g Europium-ISS                      U    0.0338    +/-0.0832    0.0769  +/-0.0832      0.154          pCi/g Lead-212                                  0.919    +/-0.109    0.0385  +/-0.109      0.077          pCi/g Lead-214                                0.992    +/-0.147    0.0464  +/-0.147    0.0928          pCi/g Manganese-54                      U    0.0176    +/-0.0274      0.022 +/-0.0274    0.0439          pCi/g Niobium-94                        U -0.00378    +/-0.0244    0.0204  +1-0.0244    0.0408          pCi/g Potassium-40                              11.1      +/-1. 11    0.190    +/-].1 1    0.380          pCi/g Radium-226                                0.927    +/-0.142    0.0436  +/-0.142    0.0871          pCi/g Silver- 108m                      U -0.00504    +/-0.0243    0.0212  +/-0.0243    0.0423          pCi/g Thallium-208                              0.327  +/-0.0584    0.0218  +/-0.0584    0.0436          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90                          0.0632    +/-0.031    0.0176 +/-0.0311      0.0417          pCi/g            KSDI 04/04/07 1305 621435 The following Prep Methods were performed Method              Description                                            Analyst      Date            Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                              JMB 1        03/30/07          1052    621413 The following Analytical Methods were performed Method              Description 1                    EML HASL 300,4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tracer recovery          Test                                  Recovery%          Acceptable Limits Page 19 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171    - www.gel.com Certificate of Analysis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                              Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:    Soils PO# 002332 Client Sample ID:                9312-0010-125-I              Project:      YANK01204 Sample ID:                        183321002                    Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result  Uncertainty    LC    TPU        MDA        Units        DF Analyst Date      Time Batch 1%
Surrogate/Tracer recovery      Test                                Recovery%        Acceptable Limits Strontium Carrtier              GFPC, SrOO, solid-ALL FSS                80            (25%-i 25%)
Notes:
The Qualifiers in this report are defined as follows:
    **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A  RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 20 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171        -  www.gel.com Certificate of Aknalvsis Analvsis Company:    Connecticut Yankee Atomic Power Address:    362 Injun Hollow Rd East Hampton, Connecticut 06424                                                    Report Date:  April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                93 12-0010-126-I                  Project:        YANKO 1204 Sample ID:                        183321003                        Client ID: YANKOO 1 Matrix:                          TS                                Vol. Recv.:
Collect Date:                    29-MAR-07 Receive Date:                    30-MAR-07 Collector:                        Client Moisture:                        .359%
Parameter                    Qualifier  Result  Uncertainty      LC      TPU      MDA          Units          DF Analyst Date      Time Batch 1%
Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 In growth Waived Actinium-228                            0.901    +/-0.203  0.0693    +/-0.203    0.139          pCilg              MJHI1 04/04/07 0104 622281 Americium-241                    U    0.0967    +/-0.095  0.0826    +/-0.095    0.165          pCi/g Bismuth-212                            0.716    +/-0.375    0.170  +/-0.375    0.339          pCi/g Bismuth-214                            0.692    +/-0.116  0.0436    +/-0.116  0.0872          pCi/g Cesium-134                        U    0.0265  +1-0.0275  0.0256  +/-0.0275  0.0511          pCi/g Cesium-] 37                      U    0.0286  +/-0.0453  0.0231  +/-0.0453  0.0461          pCi/g Cobalt-60                        U -0.0291    +/-0.0304  0.0182  +/-0.0304  0.0364          pCi/g Europium-152                      U -0.0939      +/-0.108  0.0602    +/-0.108    0.120          pCi/g Europium-154                      U -0.00962    +/-0.0833  0.0693  +/-0.0833    0.139          pCi/g Europium-ISS                      U    -0.021  +/-0.0789    0.072  +/-0.0789    0.144          pCi/g Lead-212                                0.959    +/-0.108  0.0363  +/-0.108  0.0725          pCi/g Lead-214                                0.644    +/-0.119  0.0447    +/-0.119  0.0893          pCi/g Manganese-54                      U    0.0326  +/-0.0322    0.0218  +/-0.0322  0.0436          pCi/g Niobium-94                        U -0.00321    +/-0.0298    0.02 16 +/-0.0298  0.0431          pCi/g Potassium-40                            16.9    +/-1.49    0.205    +/-1.49    0.410          pCi/g Radium-226                              0.692    +/-0.116  0.0436  +/-0.116  0.0872          pCi/g Silver-108m                      U -0.0109    +/-0.0229    0.0197  +/-0.0229  0.0394          pCi/g Thallium-208                            0.312  +/-0.0601    0.0198  +/-0.0601  0.0395          pCi/g Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL ESS Strontium-90                    U -0.00905    +/-0.0187    0.0174 +/-0.0187    0.0413          pCi/g              KSDI 04/04/07 1841 621435 The following Prep Methods were performed Method              Description                                            Analyst      Date              Time      Prep Batch Dry Soil Prep        Dry Soil Prep GL-RAD-A-021                            JMBI        03/30/07          1052    621413 The following Analytical Methods were performed Method              Description I              EML HASL 300,4.5.2.3 2                    EPA 905.0 Modified Surrogate/Tiracer recovery      Test                                  Recovery%          Acceptable Limits Page 21 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171    - www.gel.com Certificate of Analy:sis Company      Connecticut Yankee Atomic Power Address:      362 Injun Hollow Rd East Hampton, Connecticut 06424                                            Report Date: April 5, 2007
 
==Contact:==
Mr. Jack McCarthy Project:      Soils PO# 002332 Client Sample ID:                  93 12-0010-126-I            Project:      YANK01204 Sample ID:                          183321003                  Client ID: YANKOO I Vol. Recv.:
Parameter                  Qualifier    Result    Uncertainty    LC    TPU      MDA        Units        DF Analyst Date      Time Batch l%
Surrogate/Tracer recovery        Test                                  Recovery%      Acceptable Limits Strontium Carrier                GFPC, Sr90, solid-ALL FSS                72          (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
  **  Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A The TIC is a suspected aldol-condensation product B For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 22 of 28
 
QUALITY CONTROL DATA Page 23 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407  - (843) 556-8171  - www.gel.com QC Summary                            Report Date: April 5,2007 lent:          Connecticut Yankee Atomic Power                                                                  Page 1 of 5 362 Injun Hollow Rd East Hampton, Connecticut
.ontact:        Mr. Jack McCarthy Vorkorder:      183321 armname                                  NOM            Sample Oual      OC      Units    RPD%    REC %      Range    Anlst  Date Time ad Gamma Spec itch          622281 183322021 DUP
,ctinium-228                                                0.750        0.746        pCi/g      I          (0%  -100%)  MJHI  04/04/07 10:30 Uncert:      +/-0.190    +/-0.211 TPU:    +/-0.190      +/-0.211
,mericium-24 1                                    u      0.0469  U    0.0308        pCi/g      42          (0%  -100%)
Uncert:    +/-0.0916    +/-0.0391 TPU:    +/-0.0916    +/-0.0391
-ismuth-212                                                0.738        0.679        pCi/g      8          (0%  -100%)
Uncert:      +/-0.35 1    +/-0.309 TPU:      +/-0.351    +/-0.309
*ismuth-214                                                0.634        0.616        pCi/g      3          (0%  -100%)
Uncert:      +/-0.117    +/-0.119 TPU:      +/-0.117    +/-0.119 esium- 134                                      u      0.0503  U    0.0121        pCi/g    123          (0%  -100%)
Uncert:    +/-0.0327      +/-0.032 TPU:    +/-0.0327      +/-0.032
.esium- 137                                      u      -0.033  U    0.0358        pCi/g  4980          (0%  -100%)
Uncert:    +/-0.0315    +/-0.0276 TPU:    +1-0.03 15    +/-0.0276 u      0.0197  U  -0.0106        pCi/g    665          (0%  -100%)
Uncert:    +/-0.0269    +/-0.0264
,uobalt-602 TPU:    +1-0.0269    +/-0.0264 u      0.0308  U  0.00845        pCi/g    114          (0%  -100%)
Uncert:    +/-0.0737      +/-0.067
.uropium- 152 TPU:    +/-0.0737      +/-0.067 u  -0.00474  U    0.0134        pCi/g    420          (0%  -100%)
Uncert:    +/-0.0849    +/-0.0771
  ,uropium-154 TPU:    +/-0.0849    +/-0.0771 U      0.0261  U    0.0164        pCi/g      45          (0%  -100%)
Uncert:    +/-0.0784    +/-0.05 71 uroiu-2155 TPU:    +/-0.0784    +/-0.0571 0.767        0.89 1      pCi/g      15            (0%  -20%)
Uncert:    +/-0.0966      +/-0.119
  ,ead-212 TPU:    +/-0.0966      +/-0.119 0.568        0.634        pCi/g      11            (0%  -20%)
Uncert:      +/-0.117    +/-0.121 TPU:      +/-0.117    +/-0.121 langanese-54                                      U    -0.0118  U    0.0177        pCi/g    987          (0%  -100%)
Uncert:    +/-0.0242    +/-0.0275 TPU:    +/-0.0242    +/-0.0275 liobium-94                                        U  -0.00311  U    0.0103        pCi/g    374          (0%  -100%)
Uncert:    +/-0.0228    +/-0.0234 TPU:    +/-0.0228    +/-0.0234 Page 24 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407      - (843) 556-8171  - www.gel.com QC Summary Vorkorder:      183321                                                                                            Page 2 of 5 armname                                NOM            Sample Qual          0(7      Units    RPD%    REC%      Range  AnIst  Date Time ad Gamma Spec itch          622281 otassium-40                                                  12.5            14.2        pCi/g    13          (0%  -20%)
Uncert:        +/-1.21        +/-1.29 TPU:        +/-1.21        +/-1.29
.adium-226                                                0.634          0.616        pCilg      3          (0% -100%)
Uncert:      +/-0.117      +1-0.119 TPU:      +/-0.117      +/-0.119 ilver-1I08m                                        u    0.00407  U  -0.00551            pCilg  1330          (0% -100%)
Uncert:    +/-0.0247    +/-0.0219 TPU:    +/-0.0247    +/-0.0219
'hallium-208                                              0.266          0.269        pCilg      I          (0% -100%)
Uncert:    +/-0.0599    +/-0.0584 TPU:    +1-0.0599    +/-0.0584 LCS
,ctinium-228                                                              0.795        pCilg                                  04/04/07 10:19 Uncert:                    +/-0.718 TPU:                    +/-0.718
,meiicium-241                            16.4                                14.0        pCilg              85 (75%-125%)
Uncert:                      +/- 1.52 TPU:                        +/-1.52
;ismuth-2 12                                                    U          1.15        pCilg Uncert:                    +/-0.883 TPU:                    +/-0.883
;ismuth-2 14                                                              0.777        pCilg Uncert:                    +/-0.311 TPU:                    +1-0.311 eIum    3                                                      U        0.092        pCilg Uncert:                    +/-0.112
.esium-137 TPU:                    +/-0.112 6.35                                6.09        pCilg              96 (75%-125%)
Uncert:                    +/-0.577 TPU:                    +/-0.577
'obalt-60                              9.55                                9.26        pCi/g              97 (75%-125%)
Uncert:                    +/-0.685 TPU:                    +1-0. 685
,uropium-1552                                                    U    -0.0231          pCilg Uncert:                    +/-0.282 TPU:                    +/-0.282
,uropium- 154                                                    U    -0.0844          pCi/g Uncert:                      +1-0.238 TPU:                    +/-0.238
,uropium-155                                                    U        0.123        pCilg Uncert:                      +/-0.319 TPU:                    +1-0.3 19
,ead-21 2                                                                    1.30      pCilg Uncert:                    +/-0.258 TPU:                    +/-0.258
.ead-214                                                                    1.05      pCilg Uncert:                    +/-0.316 Page 25 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171  - www.gel.com QC Summary Vorkorder:      183321                                                                                        Page 3 of 5 armname                              NOM          Sample Qual          OC      Units    RPD%    REC%      Range  Anist  Date  Time ad Gamma Spec itch          622281 TPU:                      +/-0.316 langanese-54                                                  U        0.036        pCi/g Uncert:                    +/-0.0981 TPU:                    +/-0.0981 liobium-94                                                    U        0.0841        pCi/g Uncert:                    +/-0.0973 TPU:                    +/-0.0973 otassium-40                                                              4.73        pCi/g Uncert:                        +/-3.49 TPU:                        +/-3.49
.adium-226                                                            0.777        pCi/g                (75%-1 25%)
Uncert:                      +1-0.311 TPU:                      +/-0.311 ilver-1 08m                                                  U      -0.0118          pCi/g Uncert:                    +1-0.0942 TPU:                    +/-0.0942 hallium-208                                                            0.420        pCi/g Uncert:                      +/-0.178 TPU:                      +/-0.178 QC1201307871      MB
,ctinium-228                                                U      -0.0653          pCi/g                                  04/04/07 07:14 Uncert:                    +/-0.0772 TPU:                    +/-0.0772
.tnericium-241                                              U        0.036        pCi/g Uncert:                    +/-0.0585 TPU:                    +/-0.0585
-ismuth-212                                                  U        -0.12        pCi/g Uncert:                      +/-0.191 TPU:                      +/-0.191 U          0.034        pCi/g Uncert:                    +/-0.0581 TPU:                    +/-0.0581
.esium-1 34                                                  U      0.00123          pCi/g Uncert:                    +/-0.0192 TPU:                    +/-0.0192
.esium- 137                                                  U      0.00558        pCi/g Uncert:                  +/-0.0392 TPU:                  +/-0.0392
'obalt-60                                                    U      0.00413        pCi/g Uncert:                  +/-0.0209 TPU:                    +/-0.0209
.uropium- 152                                                U      -0.0206          pCi/g Uncert:                    +/-0.0539 TPU:                    +/-0.0539
.uropium- 154                                                U      -0.0213          pCi/g Uncert:                    +/-0.0507 TPU:                    +/-0.0507
,uropium- 155                                                U        0.0442        pCi/g Page 26 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407    - (843) 556-8171 - www.gel.com QC Summary Vorkorder:        183321                                                                                              Page 4 of 5 armname                                        NOM          Sample Qal        QC      Units    RPD%    REC%9/    Range  AnIst  Date Time ad Gamma Spec itch            622281 Uncert:                  +/-0.0515 TPU:                  +/-0.0515
,ead-21 2                                                              U        0.038        pCilg Uncert:                  +1-0.0644 TPU:                  +1-0 .0644
,ead-214                                                              U        0.080        pCi/g Uncert:                  +/-0.0602 TPU:                  +/-0.0602 langanese-54                                                            U      0.0255        pCilg Uncert:                  +/-0.0213 TPU:                  +/-0.0213 liobium-94                                                              U      0.0222        pCilg Uncert:                  +/-0.0194 TPU:                  +/-0.0194 otassium-40                                                            U        0.123        pCilg Uncert:                    +/-0.296 TPU:                    +/-0.296
.adiumn-226                                                            U        0.034        pCilg Uncert:                  +/-0.0581 TPU:                  +/-0.0581 ilver- 108m                                                            U    0.00882        pCilg Uncert:                +/-0.0201 TPU:                  +/-0.0201 halliumn-208                                                          U    0.00326        pCilg Uncert:                  +/-0.0332 TPU:                  +/-0.0332 ad Gas Flow itch            621435 QC1201305975      183322004 DUP trontium-90                                              U  0.00529  U      0.0189        pCi/g      0        (0%- 100%) KSDI  04/04/07 13:09 Uncert:    +/-0.022      +/-0.0233 TPU:    +/-0.022      +/-0.0233 QC1201305977      LCS trontium-90                                    1.45                              1.42      pCilg            98 (75%-125%)      04/04/07 13:10 Uncert:                  +/-0.0995 TPU:                  +/-0.108 QC1201305974        MB trontium-90                                                          U  -0.000898          pCilg                                04/04/07 13:09 Uncert:                  +/-0.0194 TPU:                  +/-0.0194 QC1201305976    183322004 MIS trontium-90                                    1.66      U  0.00529            1.45      pCilg            87 (75%-125%)      04/04/07 13:09 Uncert:    +/-0.022      +/-0.111 TPU:    +/-0.022      +/-0.120 qotes:
rhe Qualifiers in this report are defined as follows:
Page 27 of 28
 
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407            - (843) 556-8171 - www.gel.com QC Summary Vorkorder:        183321                                                                                                              Page 5 of 5 armname                                        NOM              Sample OQua[l            C      Units RPD%          REC%          Range    Anist Date Time
      ** Analyte is a surrogate compound
* Result is less than value reported
* Result is greater than value reported A      The TIC is a suspected aldol-condensation product B      For General Chemistry and Organic analysis the target analyte was detected in the associated blank.
BD Results are either below the MDC or tracer recovery is low C      Analyte has been confirmed by GC/MS analysis D    Results are reported from a diluted aliquot of the sample H      Analytical holding time was exceeded J      Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the detection limit R    Sample results are rejected U    Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI    Gamma Spectroscopy--Uncertain identification
* Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
* QC Samples were not spiked with this compound A    RPD of sample and duplicate evaluated using +I-RL. Concentrations are <5X the RL h    Preparation or preservation holding time was exceeded I/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.
* Indicates analyte is a surrogate compound.
The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the ample is greater than        five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is
-ss than 5X the RL, a control limit of +/- the      RL is used to evaluate the DUP result.
Ior PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Vhere the analytical method has been performed under NELAP certification, the analysis has met all of the
-quirements of the NELAC standard unless qualified on the QC Summary.
Page 28 of 28
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)
Revision 0
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)
Revision 0
 
Health Physics Procedure            GPP-GGGR-R512 1-001 Attachment B, Rev. CY-00 1 MAJOR I-Iealth Physics Procedure          GPP-GGGR-R5121-001 Attachment B, Rev. CY-QOl MAJOR Preliminary Data Review Form          - Samples for the Sign Test Survey Unit:        9312- 0010 Survey Unit Name: Northeast Protected Area Grounds Classification:      I Survey Media:      Soil Type of Survey:  Final Status Survey Type of Measurement:    Gross Measurement Number of Measurements:            18 Operational DCGL:          1 I-BASIC STATISTICAL QUANTITIES                  -
Cs-137          Co-60          Sr-90 Minimum Value:    -2.35E-02      -1.72E-02      -2.23E-02 Maximum Value:    1.9 1E+00      3.48E-02        3.70E-02 Mean:  3.16E-01      6.18E-03        4.12E-03 Median:  7.48E-02      8.25E-04        4.18E-03 Standard Deviation:  5.48E-0 I      1.42E-02      1.80E-02 RADIONUCLIDE CONCENTRATION (pCilg)
NUMBER                Cs- 137        Co-60          Sr-90      Identified? Identified? Identified?
93 12-00 10-IOIF        2.56E-01      3.48E-02      -1.97E-02          Y            N          N 93 12-0010-102F        1.60E+00      0.OOE+00        2.53E-02          Y            N          N 9312-0010-103F          1.91E+00      0.OOE+00        2.54E-02          Y            N          N 93 12-0010-104F        1 .44E-01      8.09E-03      3.70E-02          Y            N          Y 9312-0010-105F          8.70E-02      -5. 1 5E-03    -1.05E-02        Y            N          N 9312-0010-106F          2.88E-02      1.74E-02      -2.23 E-02        Y            N          N 93 12-0010-107F        0.OOE+00      -9.39E-03      -1.55E-02        N            N          N 9312-0010-108F          4.1 8E-02      2.1 3E-02      8. 14E-03        N          N          N 9312-0010-109F          2.76E-01      2.92E-02        1.91 E-02        Y          N          N 93 12-0010-IIOF        4.30E-01      1.63E-02      -1.05E-02          Y          N          N 9312-0010-11IIF          1.91 E-02    -5.55E-03        2.40E-03          N          N          N 93 12-0010-1 12F      -2.35E-02      -2.30E-03        I1.05E-02        N          N          N 93 12-0010-1 13F        6.26E-02      -1 .72E-02      -1.63E-02          Y          N          N 9312-0010-1 14F        4.96E-01      0.OOE+00        2.75E-02          Y          N          Y 93 12-0010-1 15F        7.48E-03      1.65E-03      -6.57E-03          N          N          N 93 12-0010-116F        -3.85E-03      2.50E-03        1.16E-03          N          N          N 93 12-0010-1 17F        2.91 E-01      2.21 E-02      1 .30E-02        Y          Y          N 9312-0010-118F          6.19E-02      -2.46E-03        5.96E-03          Y          N          N Performed By:    )g?- 1/2f                            Date:_        -V9 Independent                                                  Date:  4 1 M4)0-
 
Health Physics Procedure                              24265-000-GPP-GGGR-R5123-000-Rev.CY-000 Attachment B Health Physics Procedure                              24265-000-GPP-GGGR-R5 123-000-Rev.CY-000 Attachment B Preliminary Data Review Form          - Judgemental Samples Survey Unit:          9312- 0010 Survey Unit Name:
Northeast Protected Area Grounds Classification:        I Survey Media:        Soil Type of Survey: Final Status Survey Type of Measurement: Gross Measurement Number of Measurements:            8 Operational DCGL:            1 BASIC STATISTICAL QUANTITIES Cs-137        Co-60          Sr-90 Minimum Value: 2.86E-02          -2.9 1E-02    -9.05E-03 Maximum Value: 2.25E+00            1.25E-01      6.32E-02 Mean: 4.72E-0 1        2.22E-02      1.62E-02 Median: 2.87E-0 1        1.42E-02      1.24E-02 Standard Deviation: 7.3 1lE-0OI        4.43E-02      2.1 7E-02 RADIONUCLIDE CONCENTRATION (pCilg)
NUMBER                  Cs- 137        Co-60          Sr-90  Identified?
93 12-0010-1 19B          2.25E+00      1.25E-01      7.53E-03      Y            Y          N 93 12-0010-120B            3.71 E-01    1.50E- 02      1.28E-04      Y            N          N 9312-0010-121B            2.34E-01      1.35E-02      1.58E-02      Y            N          N 9312-0010-122B            3.35E-02      1.02E-02      9.06E-03      N            N          N 9312-0010-123B            3.40E-01      8.95E-03      2.29E-02      Y            N          N 9312-0010-1241            1 .63E-01      1.95E-02      1.99E-02      Y            N          N 9312-0010-1251            3.54E-01      1.48E-02      6.32E-02      Y            N          Y 9312-0010-1261            2.86E-02      -2.91 E-02    -9.05E-03      N            N          N Performied By:      72A2I                                      Date:  4(-zq -Qo Independent Review,                            ~y                    Date: 'qI Z-4)c. 7
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)
Revision 0
 
Health Physics Procedure                                                        GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure                                                        GGGR-R5 I 23-Rev.CY-OO 1 Attachment C Quantile Plot For Cesium              - 137 Survey Unit:                  9312-0010 Survey Unit Name: Northeast Protected Area Grounds Mean:                    3.16E-01 pCi/g r
2.50E+00 0.
      -~2.OOE+00
    .a 1.50E+00
                      -    -    -      -I-f-            _
                                                                                          ~~7II]J 0
L) 1.OOE+00                    .. W  -      -    I-
                                                                                      -*r- r -4 L~~iI  9-    -  I- "  .
                                                                "167  &-1. -    -*
0  5.OOE-O1
                              -*1-    I    -I 310    40O      50O        610      7i      891      9p 1    210 10                                                                              90 Percentage Cs-137            Rank              Percentage
                                        -2.35E-02                1                    3%
                                        -3.85E-03                2                    8%
0.OOE+00                3                  14 %
7.48E-03                4                  19 %
1.91 E-02              5                  25 %
2.88E-02                6                  31 %
4.18E-02                7                  36 %
6.19E-02                8                  42 %
6.26E-02                9                  47 %
8.70E-02              10                  53 %
1.44E-01              11                  58 %
2.56E-01              12                  64 %
2,76E-01              13                  69 %
2.91E-01              14                  75 %
4.30E-01              15                  81 %
4.96E-01              16                  86 %
1.60E+'00              17                  92 %
1.91 E+00              18                  97 %
Prepared By:_                    -/1                                        Date:    I/ - -</-0 7 Reviewed B                                                                    Date:  4 17.4107
 
Health Physics Procedure                                Healh Pysis PoceureGGGR-R5 123 -Rev. CY-001I Attachment C Frequency Plot For Cesium-137 Survey Unit:      93 12-00 10 Survey Unit Name: Northeast Protected Area Grounds Mean:        0.3 16 pCi/g 12-10 2 4 U-2 0L 0.00      0.40            0.80        1.20            1.60        2.00 Upper End Value (pCilg)
Upper End    Observation Observation %
Value        Frequency  Frequency 0.00
* 3        17%
0.40            11        61%
0.80              2        11%
1.20            0          0%
1.60            1          6%
2.00              1          6%
Total            18        100%
Prepared By:                              ~d9                      Date:    4'-2q-cQ7Z ReviewedDae                                                          Date:  4) 2.1)07
 
Health Physics Procedure                                            GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure                                            GGGR-R5 123-Rev.CY-0O1 Attachment C Quantile Plot For Cobalt - 60 Survey Unit:          93 12-0010 Survey Unit Name: Northeast Protected Area Grounds Mean:          6.18E-03 pCi/g 4.OOE-02 3.OOE-02      --
2O.20E-02 1.OOE-02 0.00E+00    -      _  --  1.
110)            30      40        50    60      710      810    90  10 U-1.00E-02      --                                    __
Percentage Co-60            Rank            Percentage
                                  -1.72E-02              1              3 %
                                  -9.39E-03            2                8%
                                  -5.55E-03            3              14 %
                                  -5.15E-03            4              19 %
                                  -2.46E-03              5            25 %
                                  -2.30E-03            6              31 %
0.OOE+00              7            36 %
0.OOE+O0              8            42 %
0.OOE+00              9            47 %
1.65E-03            10            53 %
2.50E-03            11            58 %
8.09E-03            12            64 %
1.63E-02            13            69 %
1.74E-02            14            75 %
2.13E-02            15            81 %
2.21 E-02            16            86 %
2.92E-02            17            92 %
3.48E-02            18            97 %
Prepared By:        )C ay."    21:&#xfd;:u        d                Date:      q-&#xfd;    O Date. 4ZAo
 
Health Physics Procedure                                                  -Rev. CY-001I Attachment C Healh Pysis PoceureGGGR-R5123 Frequency Plot For Cobalt - 60 Survey Unit:          93 12-00 10 Survey Unit Name: Northeast Protected Area Grounds Mean:          0.006 pCi/g 14 12 4)1 10 8
6 LL    4  K 2
0              I                      I      -H              I-&#xfd;          I-&#xfd; 0.005 0.010 0.015 0.020 0.025 0.030 0.035 Upper End Value (pCilg)
Upper End    Observation Observation %
Value      Frequency  Frequency 0.005          12        67%
0.010          0          0%
0.015          0          0%
0.020          2          11%
0.025          2          11%
0.030            1          6%
0.035            1          6%
Total          18        100%
Prepared By:        Y_/), /      &#xfd;/Lzz/                                Date:    q2 -oZ-O  7 Reviewed                                                              ReiwdDate: '14z-4)co-7
 
Health Physics Procedure                                            GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Strontium - 90 Survey Unit:        93 12-00 10 Survey Unit Name: Northeast Protected Area Grounds Mean:          4.12E-03 pCi/g 4.OOE-02 S3.OOE-02 2.)OOE-02
    .2 o 1.OOE-02 0
        -2.OOE-02
        -3.OOE-02 Percentage Sr-90            Rank          Percentage
                                  -2.23E-02            1              3%
                                  -1.97E-02            2              8%
                                  -1.63E-02            3            14 %
                                  -1.55E-02            4              19 %
                                  -1.05E-02            5            25 %
                                  -1.05E-02
* 6            31 %
                                  -6.57E-03            7            36 %
1.16E-03            8            42 %
2.40E-03            9            47 %
5.96E-03            10            53 %
8.14E-03            11            58 %
1.05E-02            12            64 %
1.30E-02            13            69 %
1.91E-02            14            75 %
2.53E-02            15            81 %
2.54E-02            16            86 %
2.75E-02            17            92 %
3.70E-02            18            97 %
Prepared By:              -Z
                                        .,,A5&#xfd;                                Date:        2/
7Y-C&#xfd; Reviewed                                                            -4 114 107 ReviewedDate:
 
Health Physics Procedure                              Healh PhsicsProcdureGGGR-R5 123 -Rev. CY-00 1 Attachment C Frequency Plot For Srontium - 90 Survey Unit:      9312-0010 Survey Unit Name: Northeast Protected Area Grounds Mean:      0.004 pCi/g 8-Cr 0
                -0.020          0.000          0.020          0.030          0.040 Upper End Value (pC i/g)
Upper End  Observation Observation %
Value    Frequency    Frequency
                              -0.020          1          6%
0.000        7            39%
0.020        6          33%
0.030        3            17%
0.040        1            6%
Total        18          100%
Prepared By:      62    L                                        Date:</-29o7 ReviewedDae                                                      Date: 4 j 2_4 10 7
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)
Revision 0
 
Health Physics Procedure                        GPP-GGGR-R5 12 1-000 Attachment A, Rev. CY-001 MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 93 12-0010 Survey Unit Name: Northeast Protected Area Grounds WP&IR: 9312-0010 Classification : I                                          I ITYPE I (a error):0.05 TYPE I (P3error):0.051 Radionuclides:          Cs- 137                  Co-60                  Sr-90 Survey Design DCGL (pCi/g):                4.75                    2.29                    0.93 Results Cs-137        Results Co-60        Results Sr-90          Weighted Sum (W,)        DCGL-Result    Sign 2.56E-01              3.48E-02            -1 .97E-02              6.92E-02                9.3 1E-0OI    1 1.60E+00              0.OOE+00              2.53E-02                3.3 7E-0 I              6.63E-01      1 1.9 1E+00            0.OOE+00              2.54E-02                4.02E-0 1              5.98E-01      1 1-44E-0l1            8.09E-03            3.70E-02                3.39E-02              9.66E-01I 8.7013-02            -5. 15E-03          -1 .0513-02              1.61E-02              9.84E-01 2.88E-02              1.74E-02            -2.23E-02                1.37E-02              9.86E-01I 0.OOE+00              -9.39E-03            -1 .55E-02              -4.11 E-03              1.OOE+00 4.18E-02              2.13E-02            8. 14E-03                1.81E-02              9.82E-0 1 2.76E-0 1              2.92E-02              1.91E-02                7.09E-02              9.29E-0 1 4.30E-01              1.63E-02            -1 .05E-02                9.77E-02              9.02E-0 1 1.91E-02            -5 .55E-03            2.40E-03                1.60E-03              9.98E-01
      -2.3 5E-02            -2.30E-03              1.05E-02              -5.96E-03              1.0 IE+00 6.26E-02            -1 .72E-02          -1 .63E-02                5.67E-03              9.94E-0 1 4.96E-0 1            0.OOE+00              2.75E-02                1.05E-01              8.95E-0 1 7-48E-03              1.65E-03            -6.57E-03                2.30E-03              9.98E-0 1
      -3.85E-03              2.50OE-03            1. 16E-03              2.82E-04              1.OOE+00 2.91lE-01            2.21 E-02            1.30E-02                7.I1OE-02              9.29E-01 6.19E-02              -2.46E-03            5.96E-03                1.20E-02              9.88E-01 Number of Positive Differences (S+):            18 Critical Value:          12                    Survey Unit:          Meets Acceptance Criterion Performed By:                        A~4A~9                                  Date:      4      ?et-  7 Independent Review:                                                                Date:    14) 2-110 7 Page 1 of 1
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)
Revision 0
 
Connecticut Yankee Decommissioning Project Health                                      24265-000-GPR-GGGR-RS 124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey Area 932                  Survey      0010 Survey                NrhatPoetdAe                  rud 931        Unit #:              Unit Name: NrhatPoetdAe                        rud Sample Plan or WPTR#: 9312-0010                                                              1SML #: 9312-0010-114 Sample
 
== Description:==
Comparison of split samples collected from sample measurement location #3 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 93 12-0010-1 14F the comparison sample was 93 12-0010-1 14FS.
_________STANDARD                                  _      ___COMPARISON_____
Radionuclide          Activity  Standard  Resolution      Agreement          Activity    Standard Comparison Acceptable (Y/N)
________          Value      Error    _____              Range            Value        Error    Ratio  _______
Cs-137            4.96E-0 1  2.56E-02        19      0.75  -    1.33    4.58E-01      2.33E-02    0.92            Y Co-60            0.OOE+00    1.22E-02          0      NONE      -          0.OOE+00      1.41E-02    N/A            N/A K-40            1.06E+01    4.05E-0 1        26      0.75  -    1.33    1.07E+01      4.39E-01    1.01            Y Comments/Corrective Actions: In consideration of the Co-60 Table is provided to show acceptance criteria used results, guidance for agreement ranges, obtained from USNRC to assess split samples.
Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such                      Resolution            Agreement Range rations cannot be made. Since both Cs-137 and K-40 was                                4          7      0.50            2.00 found to be present at an acceptable level of agreement, no                            8          15      0.60            1.66 further action is warranted.                                                        16          50      0.75            1.33 51          200      0.80            1.25
                                                                                            > 200          0.85            1.18 PromdB:Dt:Reviewed                                                  By:                  Date:
WPLR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page        1lof I
 
NORTHEAST PROTECTED AREA GROUNDS SURVEY UNIT 93 12-0010 RELEASE RECORD ATTACHMENT 4E (COMPASS POWER CURVE)
Revision 0
 
DQA Surface Soil Report Assessment Summary Site:                                    Radiological Control Area Planner(s):                              Dale Randall Survey Unit Name:                        931 2-0010 Report Number:                            1 Survey Unit Samples.                      18 Reference Area Samples:                  0 Test Performed:                            Sign                                Test Result:          Not Performed Judgmental Samples&#xfd;                        0                                  EMVC Result:          Not Performed Assessment
 
== Conclusion:==
Reject Null Hypothesis (Survey Unit PASSES)
Retrospective Power Curve 17 1 S0.9      A-          F--                            -__
                                ~        LIZZI            -              ___
                  ~0.7 F--              -
                                          ~zmz S0.6      ~--        ~--                                        -i 0,5    4--                                                                    _
                  =0.4      -H--- n-                                                -~
40.3      4-          p-
                  ~-0.2
* II-                      __
____                  F.
                                                                                      -4 0.1
                    .a0.
J---        IjzIIIIZ        ___    -      _______    _______
0.0          0&#xfd;2            0.4            0.6        0.8            1,01      1 .2 Unity Rule Sum-of Ratios, iutcludiitg backgr-oumI Prospective Power          IN    1-beta                -      Actual Power
                        -  LBGR                    --      Estimated Power
                        -  DCGL                  -.-      Retrospective Power COMPASS 0i.0.0                                                4/19/2007 41107Pg                                                Page I}}

Latest revision as of 23:09, 14 January 2025

Final Status Survey (FSS) Final Report - Phase VII - Chapter 13 of 19 - Appendix A12, Survey Unit Release Record 9312-0010, Radiologically Controlled Area East Trench South / Mwst A&B
ML071730485
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 04/27/2007
From:
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
Download: ML071730485 (208)


Text