{{#Wiki_filter:ES-401                       Record of Rejected K/As                             Form ES-401-4 Tier /         Randomly Reason for Rejection Group        Selected K/A QID #3                 The task of using the logic trees and diagnostic charts to assess safety function during the EOPs is part of the SROs function and 009 Small Break        not the Reactor Operator. The RO will provide the parameters and LOCA                  indications to the SRO to make this assessment; therefore a Generic 2.4.21 -      credible CFR 41 RO tie can not be developed.
{{#Wiki_filter:NUREG-1021, Revision 9 Page 1 of 4 ES-401 Record of Rejected K/As Form ES-401-4 Tier /
Assessing status of    Generic 2.4.6 - Knowledge of Symptom based EOP mitigation safety functions      strategies was randomly selected as a replacement from the using parameters and  required section 2.4 generic K&A statements in accordance with logic.                ES-401 Attachment 2 Item 1.
Group Randomly Selected K/A Reason for Rejection QID #3 009 Small Break LOCA Generic 2.4.21 -
QID #7                 This K&A has an asterisk and is not applicable to ANO since the HPI pumps are normally secured during RHR operations; 025 Loss of RHR therefore, a credible and operationally valid question can not be System developed on this K&A.
Assessing status of safety functions using parameters and logic.
AA1.20 - HPI AA1.12 - RCS Temperature Indication was randomly selected as a switches, indicators, RO Exam                          replacement from the other AA1 K&A statements under this lights and flow category with a RO importance rating of > 2.5.
The task of using the logic trees and diagnostic charts to assess safety function during the EOPs is part of the SROs function and not the Reactor Operator. The RO will provide the parameters and indications to the SRO to make this assessment; therefore a credible CFR 41 RO tie can not be developed.
Tier 1 meters.
Generic 2.4.6 - Knowledge of Symptom based EOP mitigation strategies was randomly selected as a replacement from the required section 2.4 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.
Group 1                        This KA knowledge was already used in QID #11; therefore, an QID #14                alternate K&A was chosen to prevent over sampling natural circulation criteria knowledge 055 Station Blackout EK1 - Effect of battery discharge rates on capacity was selected as EK1.02 - Natural a replacement as it was the only other EK1 K&A statement under Circulation Cooling this category.
QID #7 025 Loss of RHR System AA1.20 - HPI switches, indicators, lights and flow meters.
This Generic K&A statement is not applicable to the requirements QID #15                for this EOP procedure; therefore a credible CFR 41 RO tie can not 056 Loss of Off-site  be developed.
This K&A has an asterisk and is not applicable to ANO since the HPI pumps are normally secured during RHR operations; therefore, a credible and operationally valid question can not be developed on this K&A.
Power                  Generic 2.1.28 - Knowledge of the purpose and function of major Generic 2.1.1 -        system components and controls was randomly selected as a Knowledge of          replacement from the required section 2.1 generic K&A statements conduct of            in accordance with ES-401 Attachment 2 Item 1.
AA1.12 - RCS Temperature Indication was randomly selected as a replacement from the other AA1 K&A statements under this category with a RO importance rating of > 2.5.
operations requirements.
QID #14 055 Station Blackout EK1.02 - Natural Circulation Cooling This KA knowledge was already used in QID #11; therefore, an alternate K&A was chosen to prevent over sampling natural circulation criteria knowledge EK1 - Effect of battery discharge rates on capacity was selected as a replacement as it was the only other EK1 K&A statement under this category.
NUREG-1021, Revision 9 Page 1 of 4
RO Exam Tier 1 Group 1 QID #15 056 Loss of Off-site Power Generic 2.1.1 -
Knowledge of conduct of operations requirements.
This Generic K&A statement is not applicable to the requirements for this EOP procedure; therefore a credible CFR 41 RO tie can not be developed.
Generic 2.1.28 - Knowledge of the purpose and function of major system components and controls was randomly selected as a replacement from the required section 2.1 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.  


Tier /         Randomly Reason for Rejection Group        Selected K/A This K&A has an asterisk and is not applicable to ANO since we QID #31 do not have a piggy back mode of RHR with HPI pumps; therefore, a credible and operationally valid question can not be 005 Residual Heat developed on this K&A.
NUREG-1021, Revision 9 Page 2 of 4 Tier /
Removal System K4.07 - System protection logics, including high-pressure K4.08 Line up for  interlock, reset controls, and valve interlock, was randomly piggy back mode  selected as a replacement from the other K4 K&A statements with HPI.          under this category with a RO importance rating of > 2.5.
Group Randomly Selected K/A Reason for Rejection QID #31 005 Residual Heat Removal System K4.08 Line up for piggy back mode with HPI.
The Containment Spray Chemical Addition Tank was removed QID #41            from service at ANO and replace with chemical baskets in the 026 Containment    basement of Containment; therefore, a credible and operationally Spray              valid question can not be developed on this K&A.
This K&A has an asterisk and is not applicable to ANO since we do not have a piggy back mode of RHR with HPI pumps; therefore, a credible and operationally valid question can not be developed on this K&A.
A1.05 - Chemical    A1.06 - Containment spray pump cooling was randomly selected additive tank level as a replacement from the other A1 K&A statements under this and concentration. category with a RO importance rating of > 2.5.
K4.07 - System protection logics, including high-pressure interlock, reset controls, and valve interlock, was randomly selected as a replacement from the other K4 K&A statements under this category with a RO importance rating of > 2.5.
RO Exam The Auxiliary Feed Pump (AFW) (non safety) is a motor driven Tier 2 QID #42 pump and has no interrelated tie with the Main and Reheat Steam Group 1  039 Main and        System; therefore, a credible and operationally valid question can Reheat Steam System not be developed on this K&A.
QID #41 026 Containment Spray A1.05 - Chemical additive tank level and concentration.
K3.03 - Loss of    K3.05 - RCS was randomly selected as a replacement from the MRSS on AFW        other K3 K&A statements under this category with a RO pump.              importance rating of > 2.5.
The Containment Spray Chemical Addition Tank was removed from service at ANO and replace with chemical baskets in the basement of Containment; therefore, a credible and operationally valid question can not be developed on this K&A.
QID #48             It would be difficult to develop a credible exam question with a tie 063 DC Electrical  to the DC Electrical Distribution system for this KA since the Distribution        communication circuits at ANO are normally AC auctioneered powered; therefore, a credible and operationally valid question can Generic 2.4.43 -    not be developed on this K&A.
A1.06 - Containment spray pump cooling was randomly selected as a replacement from the other A1 K&A statements under this category with a RO importance rating of > 2.5.
Knowledge of emergency          Generic 2.4.31 - Knowledge of annunciators alarms and communication      indications, and use of the response instructions was randomly systems and        selected as a replacement from the required section 2.4 generic techniques.        K&A statements in accordance with ES-401 Attachment 2 Item 1.
QID #42 039 Main and Reheat Steam System K3.03 - Loss of MRSS on AFW pump.
QID #62             There is no direct tie between the Condensate system and the limitations and conditions for operation in the facility license; RO Exam  056 Condensate      therefore, a credible and operationally valid question can not be Tier 2                        developed on this K&A.
The Auxiliary Feed Pump (AFW) (non safety) is a motor driven pump and has no interrelated tie with the Main and Reheat Steam System; therefore, a credible and operationally valid question can not be developed on this K&A.
Generic 2.1.10 -
K3.05 - RCS was randomly selected as a replacement from the other K3 K&A statements under this category with a RO importance rating of > 2.5.
Group 2  Knowledge of        Generic 2.1.27 - Knowledge of system purpose and or function condition and      was randomly selected as a replacement from the required Section limitation in the  2.1 Generic K&A statements in accordance with ES-401 facility license. Attachment 2 Item 1.
RO Exam Tier 2 Group 1 QID #48 063 DC Electrical Distribution Generic 2.4.43 -
NUREG-1021, Revision 9 Page 2 of 4
Knowledge of emergency communication systems and techniques.
It would be difficult to develop a credible exam question with a tie to the DC Electrical Distribution system for this KA since the communication circuits at ANO are normally AC auctioneered powered; therefore, a credible and operationally valid question can not be developed on this K&A.
Generic 2.4.31 - Knowledge of annunciators alarms and indications, and use of the response instructions was randomly selected as a replacement from the required section 2.4 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.
RO Exam Tier 2 Group 2 QID #62 056 Condensate Generic 2.1.10 -
Knowledge of condition and limitation in the facility license.
There is no direct tie between the Condensate system and the limitations and conditions for operation in the facility license; therefore, a credible and operationally valid question can not be developed on this K&A.
Generic 2.1.27 - Knowledge of system purpose and or function was randomly selected as a replacement from the required Section 2.1 Generic K&A statements in accordance with ES-401 Item 1.  


Tier /         Randomly Reason for Rejection Group        Selected K/A The Containment Purge System was sampled in QIDs 22 and 59, QID #73 therefore, an alternate K&A was chosen to prevent over sampling RO Exam  Generic 2.3.09 -  this system.
NUREG-1021, Revision 9 Page 3 of 4 Tier /
Tier 3 Knowledge of the Generic 2.3.10 - Ability to perform procedures to reduce excessive process for levels of radiation and guard against personnel exposure was performing a randomly selected as a replacement from Section 2.3 Generic Containment Purge K&A statements with a RO importance rating of > 2.5.
Group Randomly Selected K/A Reason for Rejection RO Exam Tier 3 QID #73 Generic 2.3.09 -
A Loss of Main Feedwater while shutdown would not be an event QID #77            for the SRO candidate and there is no credible tie between the K&A statement and the Loss of Feedwater EOP. Also the Major 054 Loss of Main  event in one of the scenarios in the operating exam is very similar Feedwater          to this subject category; therefore this subject category was SRO Exam                    rejected.
Knowledge of the process for performing a Containment Purge The Containment Purge System was sampled in QIDs 22 and 59, therefore, an alternate K&A was chosen to prevent over sampling this system.
Generic 2.2.18 -
Generic 2.3.10 - Ability to perform procedures to reduce excessive levels of radiation and guard against personnel exposure was randomly selected as a replacement from Section 2.3 Generic K&A statements with a RO importance rating of > 2.5.
Tier 1 Knowledge of      Generic 2.2.22 - Knowledge of limiting conditions for operations Group 1  maintenance        and safety limits was randomly selected as a replacement from the activities during  required section 2.2 generic K&A statements in accordance with shutdown          ES-401 Attachment 2 Item 1. The 017 RCP Malfunction (Loss of operations.        RC Flow) was randomly selected as a replacement subject category.
SRO Exam Tier 1 Group 1 QID #77 054 Loss of Main Feedwater Generic 2.2.18 -
QID #82           This K&A knowledge was sampled on the RO sample plan Tier 3 QID #71 and since the SRO candidates will be taking the RO 024 Emergency section of the exam, there is no justification or operationally valid Boration reason to generate another question on this K&A statement.
Knowledge of maintenance activities during shutdown operations.
Generic 2.3.01 -
A Loss of Main Feedwater while shutdown would not be an event for the SRO candidate and there is no credible tie between the K&A statement and the Loss of Feedwater EOP. Also the Major event in one of the scenarios in the operating exam is very similar to this subject category; therefore this subject category was rejected.
Generic 2.4.6 - Knowledge of symptom based EOP mitigation Knowledge of 10 strategies was randomly selected as a replacement from the CFR 20 and related required section 2 generic K&A statements in accordance with ES-facility radiation 401 Attachment 2 Item 1.
Generic 2.2.22 - Knowledge of limiting conditions for operations and safety limits was randomly selected as a replacement from the required section 2.2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1. The 017 RCP Malfunction (Loss of RC Flow) was randomly selected as a replacement subject category.
control requirements.
QID #82 024 Emergency Boration Generic 2.3.01 -
QID #84            This K&A knowledge was sampled on the RO sample plan Tier 3 068 Control Room  QID #71 and since the SRO candidates will be taking the RO Evacuation        section of the exam, there is no justification or operationally valid SRO Exam                    reason to generate another question on this K&A statement.
Knowledge of 10 CFR 20 and related facility radiation control requirements.
Tier 1 Generic 2.3.01 -
This K&A knowledge was sampled on the RO sample plan Tier 3 QID #71 and since the SRO candidates will be taking the RO section of the exam, there is no justification or operationally valid reason to generate another question on this K&A statement.
Knowledge of 10    Generic 2.4.4 - Ability to recognize abnormal indications for Group 2                    system operating parameters which are entry-level conditions for CFR 20 and related facility radiation emergency and abnormal operating procedures was randomly control            selected as a replacement from the required section 2 generic K&A requirements.      statements in accordance with ES-401 Attachment 2 Item 1.
Generic 2.4.6 - Knowledge of symptom based EOP mitigation strategies was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.
This K&A knowledge will be sampled on one of the Admin JPMs QID #88            and a dynamic scenario on the operating Test and thus was rejected 059 Main Feedwater due to over sampling this K&A. Based on discussions with the Lead NRC Examiner, this system was also rejected.
QID #84 068 Control Room Evacuation Generic 2.3.01 -
Generic 2.4.30 System 026, Containment Spray and generic K&A 2.4.6, Knowledge of the  Knowledge of symptom Based EOP mitigation strategies, was Emergency Plan    randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.
Knowledge of 10 CFR 20 and related facility radiation control requirements.
NUREG-1021, Revision 9 Page 3 of 4
This K&A knowledge was sampled on the RO sample plan Tier 3 QID #71 and since the SRO candidates will be taking the RO section of the exam, there is no justification or operationally valid reason to generate another question on this K&A statement.
Generic 2.4.4 - Ability to recognize abnormal indications for system operating parameters which are entry-level conditions for emergency and abnormal operating procedures was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.
SRO Exam Tier 1 Group 2 QID #88 059 Main Feedwater Generic 2.4.30 Knowledge of the Emergency Plan This K&A knowledge will be sampled on one of the Admin JPMs and a dynamic scenario on the operating Test and thus was rejected due to over sampling this K&A. Based on discussions with the Lead NRC Examiner, this system was also rejected.
System 026, Containment Spray and generic K&A 2.4.6, Knowledge of symptom Based EOP mitigation strategies, was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.  


There is no credible 10 CFR 43 SRO tie between this K&A QID #91                statement and the originally selected Station Air System; therefore, 079 Station Air        a credible and operationally valid question can not be developed on System                this K&A statement or any others Station Air K&A statements.
NUREG-1021, Revision 9 Page 4 of 4 SRO Exam Tier 2 Group 2 QID #91 079 Station Air System Generic 2.4.38 -
SRO Exam                        (most have an importance rating of less than 2.5)
Ability to take action in the E-Plan procedure acting as the emergency coordinator.
Generic 2.4.38 -
There is no credible 10 CFR 43 SRO tie between this K&A statement and the originally selected Station Air System; therefore, a credible and operationally valid question can not be developed on this K&A statement or any others Station Air K&A statements.
Tier 2 Ability to take action Based on this selection, the Control Rod Drive System was Group 2 in the E-Plan          randomly selected from the Tier 2 Group 2 systems and the procedure acting as    originally selected K&A statement: Ability to take actions called the emergency          for in the facility emergency plan, including (if required) coordinator.          supporting or acting as emergency coordinator was retained for question generation.
(most have an importance rating of less than 2.5)
QID #100               This K&A is also RO knowledge and does not allow an SRO only question to be developed thus this K&A was rejected.
Based on this selection, the Control Rod Drive System was randomly selected from the Tier 2 Group 2 systems and the originally selected K&A statement: Ability to take actions called for in the facility emergency plan, including (if required) supporting or acting as emergency coordinator was retained for question generation.
Generic 2.4.34 Knowledge of RO task performed        Generic K&A 2.4.4, Ability to recognize abnormal indications for SRO Exam outside the main      system operating parameters which are entry level conditions for Tier 1 control room during    emergency and abnormal operating procedures, was randomly emergency              selected as a replacement from the required section 2 generic K&A operations including  statements in accordance with ES-401 Attachment 2 Item 1.
SRO Exam Tier 1 QID #100 Generic 2.4.34 Knowledge of RO task performed outside the main control room during emergency operations including system geography and system implications.
system geography and system implications.
This K&A is also RO knowledge and does not allow an SRO only question to be developed thus this K&A was rejected.
NUREG-1021, Revision 9 Page 4 of 4}}
Generic K&A 2.4.4, Ability to recognize abnormal indications for system operating parameters which are entry level conditions for emergency and abnormal operating procedures, was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.}}

Latest revision as of 17:47, 14 January 2025

2008-02-Final Written Exam Rejected KA
ML080700362
Person / Time
Site: Arkansas Nuclear  Entergy icon.png
Issue date: 02/29/2008
From: Garchow S
Operations Branch IV
To:
Entergy Operations
References
50-313/08-301, 50-368/08-301, ES-401-4 50-313/08-301, 50-368/08-301
Download: ML080700362 (4)


Text

NUREG-1021, Revision 9 Page 1 of 4 ES-401 Record of Rejected K/As Form ES-401-4 Tier /

Group Randomly Selected K/A Reason for Rejection QID #3 009 Small Break LOCA Generic 2.4.21 -

Assessing status of safety functions using parameters and logic.

The task of using the logic trees and diagnostic charts to assess safety function during the EOPs is part of the SROs function and not the Reactor Operator. The RO will provide the parameters and indications to the SRO to make this assessment; therefore a credible CFR 41 RO tie can not be developed.

Generic 2.4.6 - Knowledge of Symptom based EOP mitigation strategies was randomly selected as a replacement from the required section 2.4 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.

QID #7 025 Loss of RHR System AA1.20 - HPI switches, indicators, lights and flow meters.

This K&A has an asterisk and is not applicable to ANO since the HPI pumps are normally secured during RHR operations; therefore, a credible and operationally valid question can not be developed on this K&A.

AA1.12 - RCS Temperature Indication was randomly selected as a replacement from the other AA1 K&A statements under this category with a RO importance rating of > 2.5.

QID #14 055 Station Blackout EK1.02 - Natural Circulation Cooling This KA knowledge was already used in QID #11; therefore, an alternate K&A was chosen to prevent over sampling natural circulation criteria knowledge EK1 - Effect of battery discharge rates on capacity was selected as a replacement as it was the only other EK1 K&A statement under this category.

RO Exam Tier 1 Group 1 QID #15 056 Loss of Off-site Power Generic 2.1.1 -

Knowledge of conduct of operations requirements.

This Generic K&A statement is not applicable to the requirements for this EOP procedure; therefore a credible CFR 41 RO tie can not be developed.

Generic 2.1.28 - Knowledge of the purpose and function of major system components and controls was randomly selected as a replacement from the required section 2.1 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.

NUREG-1021, Revision 9 Page 2 of 4 Tier /

Group Randomly Selected K/A Reason for Rejection QID #31 005 Residual Heat Removal System K4.08 Line up for piggy back mode with HPI.

This K&A has an asterisk and is not applicable to ANO since we do not have a piggy back mode of RHR with HPI pumps; therefore, a credible and operationally valid question can not be developed on this K&A.

K4.07 - System protection logics, including high-pressure interlock, reset controls, and valve interlock, was randomly selected as a replacement from the other K4 K&A statements under this category with a RO importance rating of > 2.5.

QID #41 026 Containment Spray A1.05 - Chemical additive tank level and concentration.

The Containment Spray Chemical Addition Tank was removed from service at ANO and replace with chemical baskets in the basement of Containment; therefore, a credible and operationally valid question can not be developed on this K&A.

A1.06 - Containment spray pump cooling was randomly selected as a replacement from the other A1 K&A statements under this category with a RO importance rating of > 2.5.

QID #42 039 Main and Reheat Steam System K3.03 - Loss of MRSS on AFW pump.

The Auxiliary Feed Pump (AFW) (non safety) is a motor driven pump and has no interrelated tie with the Main and Reheat Steam System; therefore, a credible and operationally valid question can not be developed on this K&A.

K3.05 - RCS was randomly selected as a replacement from the other K3 K&A statements under this category with a RO importance rating of > 2.5.

RO Exam Tier 2 Group 1 QID #48 063 DC Electrical Distribution Generic 2.4.43 -

Knowledge of emergency communication systems and techniques.

It would be difficult to develop a credible exam question with a tie to the DC Electrical Distribution system for this KA since the communication circuits at ANO are normally AC auctioneered powered; therefore, a credible and operationally valid question can not be developed on this K&A.

Generic 2.4.31 - Knowledge of annunciators alarms and indications, and use of the response instructions was randomly selected as a replacement from the required section 2.4 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.

RO Exam Tier 2 Group 2 QID #62 056 Condensate Generic 2.1.10 -

Knowledge of condition and limitation in the facility license.

There is no direct tie between the Condensate system and the limitations and conditions for operation in the facility license; therefore, a credible and operationally valid question can not be developed on this K&A.

Generic 2.1.27 - Knowledge of system purpose and or function was randomly selected as a replacement from the required Section 2.1 Generic K&A statements in accordance with ES-401 Item 1.

NUREG-1021, Revision 9 Page 3 of 4 Tier /

Group Randomly Selected K/A Reason for Rejection RO Exam Tier 3 QID #73 Generic 2.3.09 -

Knowledge of the process for performing a Containment Purge The Containment Purge System was sampled in QIDs 22 and 59, therefore, an alternate K&A was chosen to prevent over sampling this system.

Generic 2.3.10 - Ability to perform procedures to reduce excessive levels of radiation and guard against personnel exposure was randomly selected as a replacement from Section 2.3 Generic K&A statements with a RO importance rating of > 2.5.

SRO Exam Tier 1 Group 1 QID #77 054 Loss of Main Feedwater Generic 2.2.18 -

Knowledge of maintenance activities during shutdown operations.

A Loss of Main Feedwater while shutdown would not be an event for the SRO candidate and there is no credible tie between the K&A statement and the Loss of Feedwater EOP. Also the Major event in one of the scenarios in the operating exam is very similar to this subject category; therefore this subject category was rejected.

Generic 2.2.22 - Knowledge of limiting conditions for operations and safety limits was randomly selected as a replacement from the required section 2.2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1. The 017 RCP Malfunction (Loss of RC Flow) was randomly selected as a replacement subject category.

QID #82 024 Emergency Boration Generic 2.3.01 -

Knowledge of 10 CFR 20 and related facility radiation control requirements.

This K&A knowledge was sampled on the RO sample plan Tier 3 QID #71 and since the SRO candidates will be taking the RO section of the exam, there is no justification or operationally valid reason to generate another question on this K&A statement.

Generic 2.4.6 - Knowledge of symptom based EOP mitigation strategies was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.

QID #84 068 Control Room Evacuation Generic 2.3.01 -

Knowledge of 10 CFR 20 and related facility radiation control requirements.

This K&A knowledge was sampled on the RO sample plan Tier 3 QID #71 and since the SRO candidates will be taking the RO section of the exam, there is no justification or operationally valid reason to generate another question on this K&A statement.

Generic 2.4.4 - Ability to recognize abnormal indications for system operating parameters which are entry-level conditions for emergency and abnormal operating procedures was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.

SRO Exam Tier 1 Group 2 QID #88 059 Main Feedwater Generic 2.4.30 Knowledge of the Emergency Plan This K&A knowledge will be sampled on one of the Admin JPMs and a dynamic scenario on the operating Test and thus was rejected due to over sampling this K&A. Based on discussions with the Lead NRC Examiner, this system was also rejected.

System 026, Containment Spray and generic K&A 2.4.6, Knowledge of symptom Based EOP mitigation strategies, was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.

NUREG-1021, Revision 9 Page 4 of 4 SRO Exam Tier 2 Group 2 QID #91 079 Station Air System Generic 2.4.38 -

Ability to take action in the E-Plan procedure acting as the emergency coordinator.

There is no credible 10 CFR 43 SRO tie between this K&A statement and the originally selected Station Air System; therefore, a credible and operationally valid question can not be developed on this K&A statement or any others Station Air K&A statements.

(most have an importance rating of less than 2.5)

Based on this selection, the Control Rod Drive System was randomly selected from the Tier 2 Group 2 systems and the originally selected K&A statement: Ability to take actions called for in the facility emergency plan, including (if required) supporting or acting as emergency coordinator was retained for question generation.

SRO Exam Tier 1 QID #100 Generic 2.4.34 Knowledge of RO task performed outside the main control room during emergency operations including system geography and system implications.

This K&A is also RO knowledge and does not allow an SRO only question to be developed thus this K&A was rejected.

Generic K&A 2.4.4, Ability to recognize abnormal indications for system operating parameters which are entry level conditions for emergency and abnormal operating procedures, was randomly selected as a replacement from the required section 2 generic K&A statements in accordance with ES-401 Attachment 2 Item 1.