{{#Wiki_filter: | {{#Wiki_filter:October 19, 2010 | ||
Michael Perito | |||
Michael Perito | Vice President, Operations | ||
Vice President, Operations | Entergy Operations, Inc. | ||
Entergy Operations, Inc. | River Bend Station | ||
River Bend Station | 5485 US Highway 61N | ||
5485 US Highway 61N | St. Francisville, LA 70775 | ||
St. Francisville, LA 70775 | |||
Subject: RIVER BEND STATION - NOTIFICATION OF INSPECTION (NRC INSPECTION | |||
Subject: RIVER BEND STATION - NOTIFICATION OF INSPECTION (NRC INSPECTION | |||
Dear Mr. Perito: | REPORT 05000458/2011002) AND REQUEST FOR INFORMATION | ||
From January 21 through January 27, 2011, reactor inspectors from the Nuclear Regulatory | |||
Commissions (NRC) Region IV office will perform the baseline inservice inspection at | Dear Mr. Perito: | ||
River Bend Station, using NRC Inspection Procedure 71111.08. Experience has shown that this | |||
inspection is a resource intensive inspection both for the NRC inspectors and your staff. In | From January 21 through January 27, 2011, reactor inspectors from the Nuclear Regulatory | ||
order to minimize the impact to your onsite resources and to ensure a productive inspection, we | Commissions (NRC) Region IV office will perform the baseline inservice inspection at | ||
have enclosed a request for documents needed for this inspection. These documents have | River Bend Station, using NRC Inspection Procedure 71111.08. Experience has shown that this | ||
been divided into two groups. The first group (Section A of the enclosure) identified information | inspection is a resource intensive inspection both for the NRC inspectors and your staff. In | ||
to be provided prior to the inspection to ensure that the inspectors are adequately prepared. | order to minimize the impact to your onsite resources and to ensure a productive inspection, we | ||
The second group (Section B of the enclosure) identifies the information the inspectors will need | have enclosed a request for documents needed for this inspection. These documents have | ||
upon arrival at the site. It is important that all of these documents are up-to-date and complete | been divided into two groups. The first group (Section A of the enclosure) identified information | ||
in order to minimize the number of additional documents requested during the preparation | to be provided prior to the inspection to ensure that the inspectors are adequately prepared. | ||
and/or the onsite portions of the inspection. | The second group (Section B of the enclosure) identifies the information the inspectors will need | ||
We have discussed the schedule for these inspection activities with your staff and understand | upon arrival at the site. It is important that all of these documents are up-to-date and complete | ||
that our regulatory contact for this inspection will be Ms. Kristi Huffstatler of your licensing | in order to minimize the number of additional documents requested during the preparation | ||
organization. Our inspection dates are subject to change based on your updated schedule of | and/or the onsite portions of the inspection. | ||
outage activities. If there are any questions about this inspection or the material requested, | |||
please contact the lead inspector Jim Drake at (817) 276-6558 (James.Drake@nrc.gov). | We have discussed the schedule for these inspection activities with your staff and understand | ||
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its | that our regulatory contact for this inspection will be Ms. Kristi Huffstatler of your licensing | ||
enclosure will be available electronically for public inspection in the NRC Public Document | organization. Our inspection dates are subject to change based on your updated schedule of | ||
Room or from the Publicly Available Records (PARS) component of NRCs document | outage activities. If there are any questions about this inspection or the material requested, | ||
please contact the lead inspector Jim Drake at (817) 276-6558 (James.Drake@nrc.gov). | |||
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its | |||
enclosure will be available electronically for public inspection in the NRC Public Document | |||
Room or from the Publicly Available Records (PARS) component of NRCs document | |||
UNITED STATES | |||
NUCLEAR REGULATORY COMMISSION | |||
R E GI ON I V | |||
612 EAST LAMAR BLVD, SUITE 400 | |||
ARLINGTON, TEXAS 76011-4125 | |||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading- | - 2 - | ||
rm/adams.html (the Public Electronic Reading Room). | |||
system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading- | |||
rm/adams.html (the Public Electronic Reading Room). | |||
Sincerely, | |||
Docket: 50-458 | |||
License: NPF-47 | |||
Enclosure: | |||
Inservice Inspection Document Request | /RA/ James Drake for | ||
cc w/enclosure: | |||
Senior Vice President and COO | |||
Entergy Operations, Inc | |||
P. O. Box 31995 | Gregory Werner, Chief | ||
Jackson, MS 39286-1995 | |||
Vice President, Oversight | Plant Support Branch 2 | ||
Entergy Operations, Inc. | |||
P. O. Box 31995 | Division of Reactor Safety | ||
Jackson, MS 39286-1995 | |||
Senior Manager, Nuclear Safety & Licensing | Docket: 50-458 | ||
Entergy Nuclear Operations | License: NPF-47 | ||
P. O. Box 31995 | |||
Jackson, MS 39286-1995 | Enclosure: | ||
Manager, Licensing | Inservice Inspection Document Request | ||
Entergy Operations, Inc. | |||
5485 US Highway 61N | cc w/enclosure: | ||
St. Francisville, LA 70775 | Senior Vice President and COO | ||
Attorney General | Entergy Operations, Inc | ||
State of Louisiana | P. O. Box 31995 | ||
P. O. Box 94005 | Jackson, MS 39286-1995 | ||
Baton Rouge, LA 70804-9005 | |||
Ms. H. Anne Plettinger | Vice President, Oversight | ||
3456 Villa Rose Drive | Entergy Operations, Inc. | ||
Baton Rouge, LA 70806 | P. O. Box 31995 | ||
Jackson, MS 39286-1995 | |||
Senior Manager, Nuclear Safety & Licensing | |||
Entergy Nuclear Operations | |||
P. O. Box 31995 | |||
Jackson, MS 39286-1995 | |||
Manager, Licensing | |||
Entergy Operations, Inc. | |||
5485 US Highway 61N | |||
St. Francisville, LA 70775 | |||
Attorney General | |||
State of Louisiana | |||
P. O. Box 94005 | |||
Baton Rouge, LA 70804-9005 | |||
Ms. H. Anne Plettinger | |||
3456 Villa Rose Drive | |||
Baton Rouge, LA 70806 | |||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
President of West Feliciana | - 3 - | ||
Police Jury | |||
P. O. Box 1921 | President of West Feliciana | ||
St. Francisville, LA 70775 | Police Jury | ||
Mr. Brian Almon | P. O. Box 1921 | ||
Public Utility Commission | St. Francisville, LA 70775 | ||
William B. Travis Building | |||
P. O. Box 13326 | Mr. Brian Almon | ||
Austin, TX 78701-3326 | Public Utility Commission | ||
Mr. Jim Calloway | William B. Travis Building | ||
Public Utility | P. O. Box 13326 | ||
Commission of Texas | Austin, TX 78701-3326 | ||
1701 N. Congress Avenue | |||
Austin, TX 78711-3326 | Mr. Jim Calloway | ||
Louisiana Department of Environmental Quality | Public Utility | ||
Radiological Emergency Planning and | Commission of Texas | ||
1701 N. Congress Avenue | |||
P. O. Box 4312 | Austin, TX 78711-3326 | ||
Baton Rouge, LA 70821-4312 | |||
Joseph A. Aluise | Louisiana Department of Environmental Quality | ||
Associate General Counsel - Nuclear | Radiological Emergency Planning and | ||
Entergy Services, Inc. | Response Division | ||
639 Loyola Avenue | P. O. Box 4312 | ||
New Orleans, LA 70113 | Baton Rouge, LA 70821-4312 | ||
Chief, Technological Hazards | |||
Joseph A. Aluise | |||
FEMA Region VI | Associate General Counsel - Nuclear | ||
800 N. Loop 288 | Entergy Services, Inc. | ||
Denton, TX 76209-3606 | 639 Loyola Avenue | ||
New Orleans, LA 70113 | |||
Chief, Technological Hazards | |||
Branch | |||
FEMA Region VI | |||
800 N. Loop 288 | |||
Denton, TX 76209-3606 | |||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
Electronic distribution by RIV: | - 4 - | ||
Regional Administrator (Elmo.Collins@nrc.gov) | |||
Deputy Regional Administrator (Chuck.Casto@nrc.gov) | |||
DRP Director (Kriss.Kennedy@nrc.gov) | Electronic distribution by RIV: | ||
DRP Deputy Director (Anton.Vegel@nrc.gov) | Regional Administrator (Elmo.Collins@nrc.gov) | ||
DRS Director (Roy.Caniano@nrc.gov) | Deputy Regional Administrator (Chuck.Casto@nrc.gov) | ||
DRS Deputy Director (Troy.Pruett@nrc.gov) | DRP Director (Kriss.Kennedy@nrc.gov) | ||
Senior Resident Inspector (Grant.Larkin@nrc.gov) | DRP Deputy Director (Anton.Vegel@nrc.gov) | ||
Branch Chief, DRP/C (Vincent.Gaddy@nrc.gov) | DRS Director (Roy.Caniano@nrc.gov) | ||
RBS Administrative Assistant (Lisa.Day@nrc.gov) | DRS Deputy Director (Troy.Pruett@nrc.gov) | ||
Senior Project Engineer, DRP/C (Bob.Hagar@nrc.gov) | Senior Resident Inspector (Grant.Larkin@nrc.gov) | ||
Project Engineer, DRP/C (Rayomand.Kumana@nrc.gov) | Branch Chief, DRP/C (Vincent.Gaddy@nrc.gov) | ||
Public Affairs Officer (Victor.Dricks@nrc.gov) | RBS Administrative Assistant (Lisa.Day@nrc.gov) | ||
Public Affairs Officer (Lara.Uselding@nrc.gov) | Senior Project Engineer, DRP/C (Bob.Hagar@nrc.gov) | ||
Project Manager (Alan.Wang@nrc.gov) | Project Engineer, DRP/C (Rayomand.Kumana@nrc.gov) | ||
Branch Chief, DRS/TSB (Michael.Hay@nrc.gov) | Public Affairs Officer (Victor.Dricks@nrc.gov) | ||
RITS Coordinator (Marisa.Herrera@nrc.gov) | Public Affairs Officer (Lara.Uselding@nrc.gov) | ||
Regional Counsel (Karla.Fuller@nrc.gov) | Project Manager (Alan.Wang@nrc.gov) | ||
Acting Regional Counsel (David.Roth@nrc.gov) | Branch Chief, DRS/TSB (Michael.Hay@nrc.gov) | ||
Congressional Affairs Officer (Jenny.Weil@nrc.gov) | RITS Coordinator (Marisa.Herrera@nrc.gov) | ||
OEMail Resource | Regional Counsel (Karla.Fuller@nrc.gov) | ||
OEDO RIV Coordinator (Geoffrey.Miller@nrc.gov) | Acting Regional Counsel (David.Roth@nrc.gov) | ||
SUNSI Review Completed: ___Y___ | Congressional Affairs Officer (Jenny.Weil@nrc.gov) | ||
7 Publicly Available | OEMail Resource | ||
SRI:PSB2 | OEDO RIV Coordinator (Geoffrey.Miller@nrc.gov) | ||
JDrake | |||
/RA/ | |||
10/19/10 | |||
OFFICIAL RECORD COPY T=Telephone | |||
SUNSI Review Completed: ___Y___ | |||
ADAMS: 7 Yes | |||
No Initials: _JFD_ | |||
7 Publicly Available Non-Publicly Available Sensitive | |||
7 Non-Sensitive | |||
SRI:PSB2 | |||
C:PSB2 | |||
JDrake | |||
GWerner | |||
/RA/ | |||
/RA/ JFD for | |||
10/19/10 | |||
10/19/10 | |||
OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax | |||
Inspection Dates: | |||
Inspection Procedures: | |||
Inspectors: | - 1 - | ||
A. | Enclosure | ||
INSERVICE INSPECTION DOCUMENT REQUEST | |||
Inspection Dates: | |||
January 21 through January 27, 2011 | |||
Inspection Procedures: | |||
IP 71111.08 Inservice Inspection (ISI) Activities | |||
Inspectors: | |||
Jim Drake, Senior Reactor Inspector (Lead Inspector - ISI) | |||
A.1 | |||
A. | |||
Information Requested for the In-Office Preparation Week | |||
The following information should be sent to the Region IV office in hard copy or | |||
electronic format (ims.certrec.com preferred), in care of Jim Drake, by November 12, | |||
2010, to facilitate the selection of specific items that will be reviewed during the onsite | |||
inspection week. The inspector will select specific items from the information requested | |||
below and then request from your staff additional documents needed during the onsite | |||
inspection week (Section B of this enclosure). We ask that the specific items selected | |||
from the lists be available and ready for review on the first day of inspection. *Please | |||
provide requested documentation electronically if possible. If requested documents are | |||
large and only hard copy formats are available, please inform the inspector(s), and | |||
provide subject documentation during the first day of the onsite inspection. If you have | |||
any questions regarding this information request, please call the inspector as soon as | |||
possible. | |||
A.1 | |||
ISI/Welding Programs and Schedule Information | |||
a) | |||
A detailed schedule (including preliminary dates) of: | |||
i) | |||
Nondestructive examinations (NDEs) planned for Class 1 & 2 systems | |||
and containment, performed as part of your ASME Section XI, Risk | |||
Informed (if applicable), and augmented ISI programs during the | |||
upcoming outage. | |||
Provide a status summary of the NDE inspection activities vs. the | |||
required inspection period percentages for this Interval by category per | |||
ASME Section XI, IWX-2400 (Do not provide separately if other | |||
documentation requested contains this information) | |||
ii) | |||
Welding activities that are scheduled to be completed during the | |||
upcoming outage (ASME Class 1, 2, or 3 structures, systems, or | |||
components (SSCs)) | |||
b) | |||
A copy of ASME Section XI Code Relief Requests and associated NRC Safety | |||
Evaluations applicable to the examinations identified above. | |||
c) | |||
A list of NDE reports (ultrasonic, radiography, magnetic particle, dye penetrate, | |||
Visual VT-1, VT-2, and VT-3), which have identified relevant conditions on Code | |||
- 2 - | |||
Enclosure | |||
Class 1 & 2 systems since the beginning of the last refueling outage. This should | |||
include the previous Section XI pressure test(s) conducted during start up and | |||
any evaluations associated with the results of the pressure tests. The list of NDE | |||
reports should include a brief description of the SSC where the relevant condition | |||
was identified. | |||
d) | |||
A list with a brief description (e.g., system, material, pipe size, weld number, and | |||
NDE performed) of the welds in Code Class 1 and 2 systems which have been | |||
fabricated due to component repair/replacement activities since the beginning of | |||
the last refueling outage, or are planned to be fabricated this refueling outage. | |||
e) | |||
If reactor vessel weld examinations required by the ASME Code are scheduled to | |||
occur during the upcoming outage, provide a detailed description of the welds to | |||
A.2 Additional information related to all ISI activities | be examined and the extent of the planned examination. Please also provide | ||
reference numbers for applicable procedures that will be used to conduct these | |||
examinations. | |||
f) | |||
Copy of any 10 CFR Part 21 reports applicable to your SSCs within the scope of | |||
Section XI of the ASME Code that have been identified since the beginning of the | |||
last refueling outage. | |||
g) | |||
A list of any temporary non-code repairs in service (e.g., pinhole leaks). | |||
h) | |||
Please provide copies of the most recent self assessments for the ISI, Welding, | |||
B. | and Alloy 600 Programs. | ||
B.1 ISI / Welding Programs and Schedule Information | A.2 | ||
Additional information related to all ISI activities | |||
a) | |||
A list with a brief description of ISI inspection related issues (e.g., condition | |||
reports) entered into your corrective action program since the beginning of the | |||
last refueling outage (for the applicable unit). For example, a list based upon | |||
data base searches using key words related to piping such as: ISI, ASME Code, | |||
Section XI, NDE, cracks, wear, thinning, leakage, rust, corrosion or errors in | |||
piping/NDE examinations. | |||
b) | |||
Please provide names and phone numbers for the following program leads: | |||
ISI contacts (Examination, planning) | |||
Containment Exams | |||
Snubbers and Supports | |||
Repair and Replacement Program Manager | |||
Licensing Contact | |||
Site Welding Engineer | |||
B. | |||
Information to be provided onsite to the inspector(s) at the entrance meeting (January | |||
21, 2011): | |||
B.1 | |||
ISI / Welding Programs and Schedule Information | |||
a) Updated schedules for ISI/NDE activities, planned welding activities, and | |||
b) For ASME Code Class 1 and 2 welds selected by the inspector from the lists | |||
- 3 - | |||
Enclosure | |||
a) | |||
Updated schedules for ISI/NDE activities, planned welding activities, and | |||
schedule showing contingency repair plans, if available. | |||
b) | |||
For ASME Code Class 1 and 2 welds selected by the inspector from the lists | |||
provided from section A of this enclosure, please provide copies of the following | |||
documentation for each subject weld: | |||
i) | |||
Weld data sheet (traveler) | |||
ii) | |||
Weld configuration and system location | |||
iii) | |||
Applicable Code Edition and Addenda for weldment | |||
iv) | |||
Applicable Code Edition and Addenda for welding procedures | |||
c) For the ISI related corrective action issues selected by the inspector(s) from | v) | ||
Applicable weld procedures (WPS) used to fabricate the welds | |||
vi) | |||
d) For the NDE reports with relevant conditions on Code Class 1 & 2 systems | Copies of procedure qualification records (PQRs) supporting the WPS | ||
from B.1.b.v | |||
vii) | |||
Copies of mechanical test reports identified in the PQRs above | |||
e) A copy of (or ready access to) most current revision of the ISI Program Manual | viii) | ||
Copies of the nonconformance reports for the selected welds (If | |||
f) For the NDEs selected by the inspector from section A of this enclosure, provide | applicable) | ||
ix) | |||
Radiographs of the selected welds and access to equipment to allow | |||
viewing radiographs (If RT was performed) | |||
x) | |||
Copies of the preservice examination records for the selected welds. | |||
xi) | |||
Copies of welder performance qualifications records applicable to the | |||
selected welds, including documentation that welder maintained | |||
proficiency in the applicable welding processes specified in the WPS (at | |||
least six months prior to the date of subject work) | |||
xii) | |||
Copies of NDE personnel qualifications (VT, PT, UT, RT), as applicable | |||
c) | |||
For the ISI related corrective action issues selected by the inspector(s) from | |||
section A of this enclosure, provide a copy of the corrective actions and | |||
supporting documentation. | |||
d) | |||
For the NDE reports with relevant conditions on Code Class 1 & 2 systems | |||
selected by the inspector from section A above, provide a copy of the | |||
examination records, examiner qualification records, and associated corrective | |||
action documents. | |||
e) | |||
A copy of (or ready access to) most current revision of the ISI Program Manual | |||
and Plan for the current Interval. | |||
f) | |||
For the NDEs selected by the inspector from section A of this enclosure, provide | |||
copy of the NDE procedures used to perform the examinations (including | |||
calibration and flaw characterization/sizing procedures). For ultrasonic | |||
examination procedures qualified in accordance with ASME Code, Section XI, | |||
Appendix VIII, provide documentation supporting the procedure qualification | |||
(e.g., the EPRI performance demonstration qualification summary sheets). Also, | |||
include qualification documentation of the specific equipment to be used (e.g., | |||
ultrasonic unit, cables, and transducers including serial numbers) and NDE | |||
personnel qualification records. | |||
B.2 | |||
- 4 - | |||
Enclosure | |||
B.2 | |||
Codes and Standards | |||
Inspector Contact Information: | |||
Jim Drake | a) | ||
Senior Reactor Inspector | Ready access to (i.e., copies provided to the inspector(s) for use during the | ||
817-276-6558 | inspection at the onsite inspection location, or room number and location where | ||
James.Drake@nrc.gov | available): | ||
Mailing Address: | |||
US NRC Region IV | i) | ||
Attn: Jim Drake | Applicable Editions of the ASME Code (Sections V, IX and XI) for the | ||
612 E. Lamar Blvd, Suite 400 | inservice inspection program and the repair/replacement program. | ||
ii) | |||
Any other applicable EPRI and industry standards referenced in the plant | |||
procedures for welding and NDE activities. | |||
Inspector Contact Information: | |||
Jim Drake | |||
Senior Reactor Inspector | |||
817-276-6558 | |||
James.Drake@nrc.gov | |||
Mailing Address: | |||
US NRC Region IV | |||
Attn: Jim Drake | |||
612 E. Lamar Blvd, Suite 400 | |||
Arlington, TX 76011 | Arlington, TX 76011 | ||
}} | }} | ||
Latest revision as of 02:27, 14 January 2025
| ML102920735 | |
| Person / Time | |
|---|---|
| Site: | River Bend |
| Issue date: | 10/19/2010 |
| From: | Greg Werner NRC/RGN-IV/DRS/PSB-2 |
| To: | Mike Perito Entergy Operations |
| References | |
| IR-11-002 | |
| Download: ML102920735 (8) | |
See also: IR 05000458/2011002
Text
October 19, 2010
Michael Perito
Vice President, Operations
Entergy Operations, Inc.
River Bend Station
5485 US Highway 61N
St. Francisville, LA 70775
Subject: RIVER BEND STATION - NOTIFICATION OF INSPECTION (NRC INSPECTION
REPORT 05000458/2011002) AND REQUEST FOR INFORMATION
Dear Mr. Perito:
From January 21 through January 27, 2011, reactor inspectors from the Nuclear Regulatory
Commissions (NRC) Region IV office will perform the baseline inservice inspection at
River Bend Station, using NRC Inspection Procedure 71111.08. Experience has shown that this
inspection is a resource intensive inspection both for the NRC inspectors and your staff. In
order to minimize the impact to your onsite resources and to ensure a productive inspection, we
have enclosed a request for documents needed for this inspection. These documents have
been divided into two groups. The first group (Section A of the enclosure) identified information
to be provided prior to the inspection to ensure that the inspectors are adequately prepared.
The second group (Section B of the enclosure) identifies the information the inspectors will need
upon arrival at the site. It is important that all of these documents are up-to-date and complete
in order to minimize the number of additional documents requested during the preparation
and/or the onsite portions of the inspection.
We have discussed the schedule for these inspection activities with your staff and understand
that our regulatory contact for this inspection will be Ms. Kristi Huffstatler of your licensing
organization. Our inspection dates are subject to change based on your updated schedule of
outage activities. If there are any questions about this inspection or the material requested,
please contact the lead inspector Jim Drake at (817) 276-6558 (James.Drake@nrc.gov).
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its
enclosure will be available electronically for public inspection in the NRC Public Document
Room or from the Publicly Available Records (PARS) component of NRCs document
UNITED STATES
NUCLEAR REGULATORY COMMISSION
R E GI ON I V
612 EAST LAMAR BLVD, SUITE 400
ARLINGTON, TEXAS 76011-4125
Entergy Operations, Inc.
- 2 -
system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading-
rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/ James Drake for
Gregory Werner, Chief
Plant Support Branch 2
Division of Reactor Safety
Docket: 50-458
License: NPF-47
Enclosure:
Inservice Inspection Document Request
cc w/enclosure:
Senior Vice President and COO
Entergy Operations, Inc
P. O. Box 31995
Jackson, MS 39286-1995
Vice President, Oversight
Entergy Operations, Inc.
P. O. Box 31995
Jackson, MS 39286-1995
Senior Manager, Nuclear Safety & Licensing
Entergy Nuclear Operations
P. O. Box 31995
Jackson, MS 39286-1995
Manager, Licensing
Entergy Operations, Inc.
5485 US Highway 61N
St. Francisville, LA 70775
Attorney General
State of Louisiana
P. O. Box 94005
Baton Rouge, LA 70804-9005
Ms. H. Anne Plettinger
3456 Villa Rose Drive
Baton Rouge, LA 70806
Entergy Operations, Inc.
- 3 -
President of West Feliciana
Police Jury
P. O. Box 1921
St. Francisville, LA 70775
Mr. Brian Almon
Public Utility Commission
William B. Travis Building
P. O. Box 13326
Austin, TX 78701-3326
Mr. Jim Calloway
Public Utility
Commission of Texas
1701 N. Congress Avenue
Austin, TX 78711-3326
Louisiana Department of Environmental Quality
Radiological Emergency Planning and
Response Division
P. O. Box 4312
Baton Rouge, LA 70821-4312
Joseph A. Aluise
Associate General Counsel - Nuclear
Entergy Services, Inc.
639 Loyola Avenue
New Orleans, LA 70113
Chief, Technological Hazards
Branch
FEMA Region VI
800 N. Loop 288
Denton, TX 76209-3606
Entergy Operations, Inc.
- 4 -
Electronic distribution by RIV:
Regional Administrator (Elmo.Collins@nrc.gov)
Deputy Regional Administrator (Chuck.Casto@nrc.gov)
DRP Director (Kriss.Kennedy@nrc.gov)
DRP Deputy Director (Anton.Vegel@nrc.gov)
DRS Director (Roy.Caniano@nrc.gov)
DRS Deputy Director (Troy.Pruett@nrc.gov)
Senior Resident Inspector (Grant.Larkin@nrc.gov)
Branch Chief, DRP/C (Vincent.Gaddy@nrc.gov)
RBS Administrative Assistant (Lisa.Day@nrc.gov)
Senior Project Engineer, DRP/C (Bob.Hagar@nrc.gov)
Project Engineer, DRP/C (Rayomand.Kumana@nrc.gov)
Public Affairs Officer (Victor.Dricks@nrc.gov)
Public Affairs Officer (Lara.Uselding@nrc.gov)
Project Manager (Alan.Wang@nrc.gov)
Branch Chief, DRS/TSB (Michael.Hay@nrc.gov)
RITS Coordinator (Marisa.Herrera@nrc.gov)
Regional Counsel (Karla.Fuller@nrc.gov)
Acting Regional Counsel (David.Roth@nrc.gov)
Congressional Affairs Officer (Jenny.Weil@nrc.gov)
OEMail Resource
OEDO RIV Coordinator (Geoffrey.Miller@nrc.gov)
SUNSI Review Completed: ___Y___
ADAMS: 7 Yes
No Initials: _JFD_
7 Publicly Available Non-Publicly Available Sensitive
7 Non-Sensitive
SRI:PSB2
C:PSB2
JDrake
GWerner
/RA/
/RA/ JFD for
10/19/10
10/19/10
OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax
- 1 -
Enclosure
INSERVICE INSPECTION DOCUMENT REQUEST
Inspection Dates:
January 21 through January 27, 2011
Inspection Procedures:
IP 71111.08 Inservice Inspection (ISI) Activities
Inspectors:
Jim Drake, Senior Reactor Inspector (Lead Inspector - ISI)
A.
Information Requested for the In-Office Preparation Week
The following information should be sent to the Region IV office in hard copy or
electronic format (ims.certrec.com preferred), in care of Jim Drake, by November 12,
2010, to facilitate the selection of specific items that will be reviewed during the onsite
inspection week. The inspector will select specific items from the information requested
below and then request from your staff additional documents needed during the onsite
inspection week (Section B of this enclosure). We ask that the specific items selected
from the lists be available and ready for review on the first day of inspection. *Please
provide requested documentation electronically if possible. If requested documents are
large and only hard copy formats are available, please inform the inspector(s), and
provide subject documentation during the first day of the onsite inspection. If you have
any questions regarding this information request, please call the inspector as soon as
possible.
A.1
ISI/Welding Programs and Schedule Information
a)
A detailed schedule (including preliminary dates) of:
i)
Nondestructive examinations (NDEs) planned for Class 1 & 2 systems
and containment, performed as part of your ASME Section XI, Risk
Informed (if applicable), and augmented ISI programs during the
upcoming outage.
Provide a status summary of the NDE inspection activities vs. the
required inspection period percentages for this Interval by category per
ASME Section XI, IWX-2400 (Do not provide separately if other
documentation requested contains this information)
ii)
Welding activities that are scheduled to be completed during the
upcoming outage (ASME Class 1, 2, or 3 structures, systems, or
components (SSCs))
b)
A copy of ASME Section XI Code Relief Requests and associated NRC Safety
Evaluations applicable to the examinations identified above.
c)
A list of NDE reports (ultrasonic, radiography, magnetic particle, dye penetrate,
Visual VT-1, VT-2, and VT-3), which have identified relevant conditions on Code
- 2 -
Enclosure
Class 1 & 2 systems since the beginning of the last refueling outage. This should
include the previousSection XI pressure test(s) conducted during start up and
any evaluations associated with the results of the pressure tests. The list of NDE
reports should include a brief description of the SSC where the relevant condition
was identified.
d)
A list with a brief description (e.g., system, material, pipe size, weld number, and
NDE performed) of the welds in Code Class 1 and 2 systems which have been
fabricated due to component repair/replacement activities since the beginning of
the last refueling outage, or are planned to be fabricated this refueling outage.
e)
If reactor vessel weld examinations required by the ASME Code are scheduled to
occur during the upcoming outage, provide a detailed description of the welds to
be examined and the extent of the planned examination. Please also provide
reference numbers for applicable procedures that will be used to conduct these
examinations.
f)
Copy of any 10 CFR Part 21 reports applicable to your SSCs within the scope of
Section XI of the ASME Code that have been identified since the beginning of the
last refueling outage.
g)
A list of any temporary non-code repairs in service (e.g., pinhole leaks).
h)
Please provide copies of the most recent self assessments for the ISI, Welding,
and Alloy 600 Programs.
A.2
Additional information related to all ISI activities
a)
A list with a brief description of ISI inspection related issues (e.g., condition
reports) entered into your corrective action program since the beginning of the
last refueling outage (for the applicable unit). For example, a list based upon
data base searches using key words related to piping such as: ISI, ASME Code,
Section XI, NDE, cracks, wear, thinning, leakage, rust, corrosion or errors in
piping/NDE examinations.
b)
Please provide names and phone numbers for the following program leads:
ISI contacts (Examination, planning)
Containment Exams
Snubbers and Supports
Repair and Replacement Program Manager
Licensing Contact
Site Welding Engineer
B.
Information to be provided onsite to the inspector(s) at the entrance meeting (January
21, 2011):
B.1
ISI / Welding Programs and Schedule Information
- 3 -
Enclosure
a)
Updated schedules for ISI/NDE activities, planned welding activities, and
schedule showing contingency repair plans, if available.
b)
For ASME Code Class 1 and 2 welds selected by the inspector from the lists
provided from section A of this enclosure, please provide copies of the following
documentation for each subject weld:
i)
Weld data sheet (traveler)
ii)
Weld configuration and system location
iii)
Applicable Code Edition and Addenda for weldment
iv)
Applicable Code Edition and Addenda for welding procedures
v)
Applicable weld procedures (WPS) used to fabricate the welds
vi)
Copies of procedure qualification records (PQRs) supporting the WPS
from B.1.b.v
vii)
Copies of mechanical test reports identified in the PQRs above
viii)
Copies of the nonconformance reports for the selected welds (If
applicable)
ix)
Radiographs of the selected welds and access to equipment to allow
viewing radiographs (If RT was performed)
x)
Copies of the preservice examination records for the selected welds.
xi)
Copies of welder performance qualifications records applicable to the
selected welds, including documentation that welder maintained
proficiency in the applicable welding processes specified in the WPS (at
least six months prior to the date of subject work)
xii)
Copies of NDE personnel qualifications (VT, PT, UT, RT), as applicable
c)
For the ISI related corrective action issues selected by the inspector(s) from
section A of this enclosure, provide a copy of the corrective actions and
supporting documentation.
d)
For the NDE reports with relevant conditions on Code Class 1 & 2 systems
selected by the inspector from section A above, provide a copy of the
examination records, examiner qualification records, and associated corrective
action documents.
e)
A copy of (or ready access to) most current revision of the ISI Program Manual
and Plan for the current Interval.
f)
For the NDEs selected by the inspector from section A of this enclosure, provide
copy of the NDE procedures used to perform the examinations (including
calibration and flaw characterization/sizing procedures). For ultrasonic
examination procedures qualified in accordance with ASME Code,Section XI,
Appendix VIII, provide documentation supporting the procedure qualification
(e.g., the EPRI performance demonstration qualification summary sheets). Also,
include qualification documentation of the specific equipment to be used (e.g.,
ultrasonic unit, cables, and transducers including serial numbers) and NDE
personnel qualification records.
- 4 -
Enclosure
B.2
Codes and Standards
a)
Ready access to (i.e., copies provided to the inspector(s) for use during the
inspection at the onsite inspection location, or room number and location where
available):
i)
Applicable Editions of the ASME Code (Sections V, IX and XI) for the
inservice inspection program and the repair/replacement program.
ii)
Any other applicable EPRI and industry standards referenced in the plant
procedures for welding and NDE activities.
Inspector Contact Information:
Jim Drake
Senior Reactor Inspector
817-276-6558
James.Drake@nrc.gov
Mailing Address:
US NRC Region IV
Attn: Jim Drake
612 E. Lamar Blvd, Suite 400
Arlington, TX 76011