{{#Wiki_filter:UNITED STATES
{{#Wiki_filter:UNITED STATES
                                  NU C LE AR RE G ULATO RY C O M M I S S I O N
NUCLEAR REGULATORY COMMISSION
                                                    R E GI ON I V
R E GI ON I V
                                          612 EAST LAMAR BLVD , SU I TE 400
612 EAST LAMAR BLVD, SUITE 400
                                          AR LIN GTON , TEXAS 76011-4125
ARLINGTON, TEXAS 76011-4125
                                                  December 20, 2010
Matthew W. Sunseri, President and
   Chief Executive Officer
Wolf Creek Nuclear Operating Corporation
P.O. Box 411
Burlington, KS 66839
SUBJECT: WOLF CREEK- NOTIFICATION OF NRC 95002 INSPECTION FOR ONE
              DEGRADED CORNERSTONE OR ANY THREE WHITE INPUTS IN A
December 20, 2010  
              STRATEGIC PERFORMANCE AREA 05000482/2011006
Dear Mr. Sunseri:
The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)
Region IV staff will conduct a supplemental inspection for one degraded cornerstone at your
facility. The inspection will be comprised of five reactor inspectors from the NRC Region IV
office. The inspection will be conducted in accordance with Inspection Procedure 95002,
"Inspection For One Degraded Cornerstone or any Three White Inputs in a Strategic
Performance Area."
The schedule for the inspection is as follows: Onsite inspection February 7-11, 2011, and
February 22-25, 2011.
Experience has shown that this inspection is resource intensive for your staff. In order to
Matthew W. Sunseri, President and
minimize the impact to your onsite resources and to ensure a productive inspection, we have
   Chief Executive Officer  
enclosed a request for documents needed for this inspection. Please note that the documents
Wolf Creek Nuclear Operating Corporation  
are requested to be provided by January 18, 2011. We request that during the onsite inspection
P.O. Box 411  
weeks, you ensure that copies of analyses, evaluations, or documentation regarding the
Burlington, KS 66839  
requested items are available. Also, appropriate personnel knowledgeable of the inspection
performance issues should be available to support the inspectors at the site during the
SUBJECT: WOLF CREEK- NOTIFICATION OF NRC 95002 INSPECTION FOR ONE  
inspection.
DEGRADED CORNERSTONE OR ANY THREE WHITE INPUTS IN A  
We have discussed the schedule for this inspection activity with your staff and understand that
STRATEGIC PERFORMANCE AREA 05000482/2011006  
our regulatory contact for this inspection will be Ms. Jenny Yunk of your management team. If
there are any questions about this inspection or the material requested, please contact the
Dear Mr. Sunseri:  
inspector, David Dumbacher, at 573-676-3181 or by email, David.Dumbacher@nrc.gov. In
The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)  
Region IV staff will conduct a supplemental inspection for one degraded cornerstone at your  
facility. The inspection will be comprised of five reactor inspectors from the NRC Region IV  
office. The inspection will be conducted in accordance with Inspection Procedure 95002,  
"Inspection For One Degraded Cornerstone or any Three White Inputs in a Strategic  
Performance Area."  
The schedule for the inspection is as follows: Onsite inspection February 7-11, 2011, and  
February 22-25, 2011.  
Experience has shown that this inspection is resource intensive for your staff. In order to  
minimize the impact to your onsite resources and to ensure a productive inspection, we have  
enclosed a request for documents needed for this inspection. Please note that the documents  
are requested to be provided by January 18, 2011. We request that during the onsite inspection  
weeks, you ensure that copies of analyses, evaluations, or documentation regarding the  
requested items are available. Also, appropriate personnel knowledgeable of the inspection  
performance issues should be available to support the inspectors at the site during the  
inspection.  
We have discussed the schedule for this inspection activity with your staff and understand that  
our regulatory contact for this inspection will be Ms. Jenny Yunk of your management team. If  
there are any questions about this inspection or the material requested, please contact the  
inspector, David Dumbacher, at 573-676-3181 or by email, David.Dumbacher@nrc.gov. In  


Wolf Creek Nuclear Operating Corporation             -2-
Wolf Creek Nuclear Operating Corporation  
accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its
- 2 -  
enclosure will be available electronically for public inspection in the NRC Public Document
Room or from the Publicly Available Records (PARS) component of NRC's document system
accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its  
(ADAMS). ADAMS is accessible from the NRC Web site at
enclosure will be available electronically for public inspection in the NRC Public Document
http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
                                              Sincerely,
Room or from the Publicly Available Records (PARS) component of NRC's document system  
                                              /RDeese for /RA/ /
(ADAMS). ADAMS is accessible from the NRC Web site at  
                                              Don Allen, Chief
http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).  
                                              Projects Branch B
                                              Division of Reactor Projects
Sincerely,  
Docket: 50-482
License: NPF-42
/RDeese for /RA/ /  
Enclosure: Inspection Procedure 95002 Documentation Request
cc w/enclosure:
Don Allen, Chief  
Site Vice President
Projects Branch B  
Wolf Creek Nuclear Operating Corporation
Division of Reactor Projects  
P.O. Box 411
Burlington, KS 66839
Docket: 50-482  
Jay Silberg, Esq.
License: NPF-42  
Pillsbury Winthrop Shaw Pittman LLP
2300 N Street, NW
Washington, DC 20037
Enclosure: Inspection Procedure 95002 Documentation Request  
Supervisor Licensing
Wolf Creek Nuclear Operating Corporation
cc w/enclosure:  
P.O. Box 411
Site Vice President  
Burlington, KS 66839
Wolf Creek Nuclear Operating Corporation  
Chief Engineer
P.O. Box 411  
Utilities Division
Burlington, KS 66839  
Kansas Corporation Commission
1500 SW Arrowhead Road
Jay Silberg, Esq.  
Topeka, KS 66604-4027
Pillsbury Winthrop Shaw Pittman LLP  
Office of the Governor
2300 N Street, NW  
State of Kansas
Washington, DC 20037  
Topeka, KS 66612-1590
Supervisor Licensing  
Wolf Creek Nuclear Operating Corporation  
P.O. Box 411  
Burlington, KS 66839  
Chief Engineer  
Utilities Division  
Kansas Corporation Commission  
1500 SW Arrowhead Road  
Topeka, KS 66604-4027  
Office of the Governor  
State of Kansas  
Topeka, KS 66612-1590  


Wolf Creek Nuclear Operating Corporation -3-
Wolf Creek Nuclear Operating Corporation  
Attorney General
- 3 -  
120 S.W. 10th Avenue, 2nd Floor
Topeka, KS 66612-1597
Attorney General  
Chairman
120 S.W. 10th Avenue, 2nd Floor  
Coffey County Courthouse
Topeka, KS 66612-1597  
110 South 6th Street
Burlington, KS 66839
Chairman  
Chief, Radiation and Asbestos
Coffey County Courthouse  
Control Section
110 South 6th Street  
Bureau of Air and Radiation
Burlington, KS 66839  
Kansas Department of Health and
Environment
Chief, Radiation and Asbestos  
1000 SW Jackson, Suite 310
  Control Section  
Topeka, KS 66612-1366
Bureau of Air and Radiation  
Chief, Technological Hazards
Kansas Department of Health and  
  Branch
  Environment  
FEMA, Region VII
1000 SW Jackson, Suite 310  
9221 Ward Parkway
Topeka, KS 66612-1366  
Suite 300
Kansas City, MO 64114-3372
Chief, Technological Hazards  
  Branch  
FEMA, Region VII  
9221 Ward Parkway  
Suite 300  
Kansas City, MO 64114-3372  


Wolf Creek Nuclear Operating Corporation           -4-
Wolf Creek Nuclear Operating Corporation  
Electronic distribution by RIV:
- 4 -  
Regional Administrator (Elmo.Collins@nrc.gov)
Deputy Regional Administrator (Art.Howell@nrc.gov)
Electronic distribution by RIV:  
DRP Director (Kriss.Kennedy@nrc.gov)
Regional Administrator (Elmo.Collins@nrc.gov)  
DRP Deputy Director (Troy.Pruett@nrc.gov)
Deputy Regional Administrator (Art.Howell@nrc.gov)  
DRS Director (Anton.Vegel@nrc.gov)
DRP Director (Kriss.Kennedy@nrc.gov)  
Senior Resident Inspector (Chris.Long@nrc.gov)
DRP Deputy Director (Troy.Pruett@nrc.gov)  
Senior Resident Inspector (David.Dumbacher@nrc.gov)
DRS Director (Anton.Vegel@nrc.gov)  
Resident Inspector (Charles.Peabody@nrc.gov)
Senior Resident Inspector (Chris.Long@nrc.gov)  
WC Administrative Assistant (Shirley.Allen@nrc.gov)
Senior Resident Inspector (David.Dumbacher@nrc.gov)  
Branch Chief, DRP/B (Don.Allen@nrc.gov)
Resident Inspector (Charles.Peabody@nrc.gov)  
Senior Project Engineer, DRP/B (Rick.Deese@nrc.gov)
WC Administrative Assistant (Shirley.Allen@nrc.gov)  
Project Engineer, DRP/B (Greg.Tutak@nrc.gov)
Branch Chief, DRP/B (Don.Allen@nrc.gov)  
Project Engineer, DRP/B (Nestor.Makris@nrc.gov)
Senior Project Engineer, DRP/B (Rick.Deese@nrc.gov)  
Public Affairs Officer (Victor.Dricks@nrc.gov)
Project Engineer, DRP/B (Greg.Tutak@nrc.gov)  
Public Affairs Officer (Lara.Uselding@nrc.gov)
Project Engineer, DRP/B (Nestor.Makris@nrc.gov)  
Project Manager (Balwant.Singal@nrc.gov)
Public Affairs Officer (Victor.Dricks@nrc.gov)  
Branch Chief, DRS/TSB (Michael.Hay@nrc.gov)
Public Affairs Officer (Lara.Uselding@nrc.gov)  
RITS Coordinator (Marisa.Herrera@nrc.gov)
Project Manager (Balwant.Singal@nrc.gov)  
Regional Counsel (Karla.Fuller@nrc.gov)
Branch Chief, DRS/TSB (Michael.Hay@nrc.gov)  
Congressional Affairs Officer (Jenny.Weil@nrc.gov)
RITS Coordinator (Marisa.Herrera@nrc.gov)  
OEMail Resource
Regional Counsel (Karla.Fuller@nrc.gov)  
OEDO RIV Coordinator (Geoffrey.Miller@nrc.gov)
Congressional Affairs Officer (Jenny.Weil@nrc.gov)  
R:\DRP\DRPDIR\WC\WC201106-RFI--DED.DOCX                   ADAMS ML 103540435
OEMail Resource  
ADAMS:       No     5 Yes       5 SUNSI Review Complete       Reviewer Initials:DBA
OEDO RIV Coordinator (Geoffrey.Miller@nrc.gov)  
                                  5 Publicly Available         5 Non-Sensitive
                                    Non-publicly Available       Sensitive
DRP:TL                 C:DRPB
  DDumbacher             DAllen
  /RA by Email/           /NMakris for/
  12/17/10               12/20/10
OFFICIAL RECORD COPY                                   T=Telephone     E=E-mail        F=Fax
R:\\DRP\\DRPDIR\\WC\\WC201106-RFI--DED.DOCX         ADAMS ML 103540435  
ADAMS:   No     5 Yes  
5 SUNSI Review Complete  
Reviewer Initials:DBA  
5 Publicly Available  
5 Non-Sensitive  
  Non-publicly Available  
  Sensitive  
DRP:TL  
C:DRPB  
   
DDumbacher  
DAllen  
   
/RA by Email/  
/NMakris for/  
  12/17/10  
12/20/10  
OFFICIAL RECORD COPY                                         T=Telephone           E=E-mail        F=Fax  


        Inspection Procedure 95002 Documentation Request
              NRC Information Request List for Wolf Creek 95002 Inspection
1. Corrective action program procedures for:
- 1 -
    *       Initiating condition reports
Enclosure
    *       Screening condition reports
Inspection Procedure 95002 Documentation Request  
    *       Assigning condition report levels
    *       Root cause generation
NRC Information Request List for Wolf Creek 95002 Inspection  
    *       Root cause methodology
    *       Effectiveness reviews
1. Corrective action program procedures for:
2. License Event Reports for all reactor trips and safety system functional failures dating
*  
    back to 2008
Initiating condition reports  
3. Condition reports for reactor trips back to 2008
*  
4. Plant logs for the associated reactor trips since 2008
Screening condition reports  
5. Condition reports for safety system functional failures since 2008
*  
6. Effectiveness reviews for the condition reports related to reactor trips and safety system
Assigning condition report levels  
    functional failures
*  
7. Condition reports evaluating the Performance Indicator thresholds for SSFF and scrams
Root cause generation  
    and scrams with complications being exceeded
*  
8. Corrective actions for condition reports evaluating the PI thresholds being exceeded
Root cause methodology  
9. Roll-up condition reports associated with Wolf Creek movement to the significant
*  
    degraded cornerstone column 3
Effectiveness reviews  
10. Training lesson plans for steam generator water level control, feedwater system,
2. License Event Reports for all reactor trips and safety system functional failures dating  
    emergency diesel systems, switchyard systems and reactor protection systems
back to 2008  
11. Post trip review packages for reactor trips since 2008
3. Condition reports for reactor trips back to 2008
12. Condition reports for common cause of crosscutting aspects related to corrective action
4. Plant logs for the associated reactor trips since 2008  
    program and human performance
5. Condition reports for safety system functional failures since 2008  
13. Planned and implemented corrective actions for common cause of crosscutting aspects
6. Effectiveness reviews for the condition reports related to reactor trips and safety system  
14. Procedures for work control processes
functional failures  
15. Quality Assurance audits of the corrective action program
7. Condition reports evaluating the Performance Indicator thresholds for SSFF and scrams  
16. Results of any benchmarking or external organization audits related to the 95002
and scrams with complications being exceeded  
    inspection
8. Corrective actions for condition reports evaluating the PI thresholds being exceeded  
17. Training and procedures related to NRC performance indicator reporting
9. Roll-up condition reports associated with Wolf Creek movement to the significant  
                                        -1-                                  Enclosure
degraded cornerstone column 3  
10. Training lesson plans for steam generator water level control, feedwater system,
emergency diesel systems, switchyard systems and reactor protection systems  
11. Post trip review packages for reactor trips since 2008
12. Condition reports for common cause of crosscutting aspects related to corrective action  
program and human performance  
13. Planned and implemented corrective actions for common cause of crosscutting aspects  
14. Procedures for work control processes  
15. Quality Assurance audits of the corrective action program  
16. Results of any benchmarking or external organization audits related to the 95002  
inspection  
17. Training and procedures related to NRC performance indicator reporting  


    18. Evaluation condition report related to traditional enforcement findings exceeding the
        threshold
    19. Condition reports related to equipment aging issues
- 2 -
    20. Condition reports related to single point of vulnerability evaluations
Enclosure
    21. Any long term equipment reliability evaluations and plans
18. Evaluation condition report related to traditional enforcement findings exceeding the  
Inspector Contact Information:     David Dumbacher
threshold  
                                    Senior Resident Inspector
19. Condition reports related to equipment aging issues  
                                    573-676-3181
20. Condition reports related to single point of vulnerability evaluations  
                                    David.Dumbacher@nrc.gov
21. Any long term equipment reliability evaluations and plans  
                                    Mailing Address:
                                    US NRC Resident Inspector Office
                                    Attn: David Dumbacher
                                    8201 NRC Road
Inspector Contact Information:  
                                    Steedman, Mo 65077-1302
David Dumbacher  
                                            -2-                                  Enclosure
Senior Resident Inspector  
573-676-3181  
David.Dumbacher@nrc.gov
Mailing Address:  
US NRC Resident Inspector Office  
Attn: David Dumbacher  
8201 NRC Road  
Steedman, Mo 65077-1302
}}
}}

Latest revision as of 01:01, 14 January 2025

Notification of NRC 95002 Inspection for One Degraded Cornerstone or Any Three White Inputs in a Strategic Performance Area 05000482-11-006
ML103540435
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 12/20/2010
From: Allen D
NRC/RGN-IV/DRP/RPB-B
To: Matthew Sunseri
Wolf Creek
References
IR-11-006
Download: ML103540435 (6)


See also: IR 05000482/2011006

Text

UNITED STATES

NUCLEAR REGULATORY COMMISSION

R E GI ON I V

612 EAST LAMAR BLVD, SUITE 400

ARLINGTON, TEXAS 76011-4125

December 20, 2010

Matthew W. Sunseri, President and

Chief Executive Officer

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

SUBJECT: WOLF CREEK- NOTIFICATION OF NRC 95002 INSPECTION FOR ONE

DEGRADED CORNERSTONE OR ANY THREE WHITE INPUTS IN A

STRATEGIC PERFORMANCE AREA 05000482/2011006

Dear Mr. Sunseri:

The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)

Region IV staff will conduct a supplemental inspection for one degraded cornerstone at your

facility. The inspection will be comprised of five reactor inspectors from the NRC Region IV

office. The inspection will be conducted in accordance with Inspection Procedure 95002,

"Inspection For One Degraded Cornerstone or any Three White Inputs in a Strategic

Performance Area."

The schedule for the inspection is as follows: Onsite inspection February 7-11, 2011, and

February 22-25, 2011.

Experience has shown that this inspection is resource intensive for your staff. In order to

minimize the impact to your onsite resources and to ensure a productive inspection, we have

enclosed a request for documents needed for this inspection. Please note that the documents

are requested to be provided by January 18, 2011. We request that during the onsite inspection

weeks, you ensure that copies of analyses, evaluations, or documentation regarding the

requested items are available. Also, appropriate personnel knowledgeable of the inspection

performance issues should be available to support the inspectors at the site during the

inspection.

We have discussed the schedule for this inspection activity with your staff and understand that

our regulatory contact for this inspection will be Ms. Jenny Yunk of your management team. If

there are any questions about this inspection or the material requested, please contact the

inspector, David Dumbacher, at 573-676-3181 or by email, David.Dumbacher@nrc.gov. In

Wolf Creek Nuclear Operating Corporation

- 2 -

accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its

enclosure will be available electronically for public inspection in the NRC Public Document

Room or from the Publicly Available Records (PARS) component of NRC's document system

(ADAMS). ADAMS is accessible from the NRC Web site at

http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RDeese for /RA/ /

Don Allen, Chief

Projects Branch B

Division of Reactor Projects

Docket: 50-482

License: NPF-42

Enclosure: Inspection Procedure 95002 Documentation Request

cc w/enclosure:

Site Vice President

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

Jay Silberg, Esq.

Pillsbury Winthrop Shaw Pittman LLP

2300 N Street, NW

Washington, DC 20037

Supervisor Licensing

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

Chief Engineer

Utilities Division

Kansas Corporation Commission

1500 SW Arrowhead Road

Topeka, KS 66604-4027

Office of the Governor

State of Kansas

Topeka, KS 66612-1590

Wolf Creek Nuclear Operating Corporation

- 3 -

Attorney General

120 S.W. 10th Avenue, 2nd Floor

Topeka, KS 66612-1597

Chairman

Coffey County Courthouse

110 South 6th Street

Burlington, KS 66839

Chief, Radiation and Asbestos

Control Section

Bureau of Air and Radiation

Kansas Department of Health and

Environment

1000 SW Jackson, Suite 310

Topeka, KS 66612-1366

Chief, Technological Hazards

Branch

FEMA, Region VII

9221 Ward Parkway

Suite 300

Kansas City, MO 64114-3372

Wolf Creek Nuclear Operating Corporation

- 4 -

Electronic distribution by RIV:

Regional Administrator (Elmo.Collins@nrc.gov)

Deputy Regional Administrator (Art.Howell@nrc.gov)

DRP Director (Kriss.Kennedy@nrc.gov)

DRP Deputy Director (Troy.Pruett@nrc.gov)

DRS Director (Anton.Vegel@nrc.gov)

Senior Resident Inspector (Chris.Long@nrc.gov)

Senior Resident Inspector (David.Dumbacher@nrc.gov)

Resident Inspector (Charles.Peabody@nrc.gov)

WC Administrative Assistant (Shirley.Allen@nrc.gov)

Branch Chief, DRP/B (Don.Allen@nrc.gov)

Senior Project Engineer, DRP/B (Rick.Deese@nrc.gov)

Project Engineer, DRP/B (Greg.Tutak@nrc.gov)

Project Engineer, DRP/B (Nestor.Makris@nrc.gov)

Public Affairs Officer (Victor.Dricks@nrc.gov)

Public Affairs Officer (Lara.Uselding@nrc.gov)

Project Manager (Balwant.Singal@nrc.gov)

Branch Chief, DRS/TSB (Michael.Hay@nrc.gov)

RITS Coordinator (Marisa.Herrera@nrc.gov)

Regional Counsel (Karla.Fuller@nrc.gov)

Congressional Affairs Officer (Jenny.Weil@nrc.gov)

OEMail Resource

OEDO RIV Coordinator (Geoffrey.Miller@nrc.gov)

R:\\DRP\\DRPDIR\\WC\\WC201106-RFI--DED.DOCX ADAMS ML 103540435

ADAMS: No 5 Yes

5 SUNSI Review Complete

Reviewer Initials:DBA

5 Publicly Available

5 Non-Sensitive

Non-publicly Available

Sensitive

DRP:TL

C:DRPB

DDumbacher

DAllen

/RA by Email/

/NMakris for/

12/17/10

12/20/10

OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax

- 1 -

Enclosure

Inspection Procedure 95002 Documentation Request

NRC Information Request List for Wolf Creek 95002 Inspection

1. Corrective action program procedures for:

Initiating condition reports

Screening condition reports

Assigning condition report levels

Root cause generation

Root cause methodology

Effectiveness reviews

2. License Event Reports for all reactor trips and safety system functional failures dating

back to 2008

3. Condition reports for reactor trips back to 2008

4. Plant logs for the associated reactor trips since 2008

5. Condition reports for safety system functional failures since 2008

6. Effectiveness reviews for the condition reports related to reactor trips and safety system

functional failures

7. Condition reports evaluating the Performance Indicator thresholds for SSFF and scrams

and scrams with complications being exceeded

8. Corrective actions for condition reports evaluating the PI thresholds being exceeded

9. Roll-up condition reports associated with Wolf Creek movement to the significant

degraded cornerstone column 3

10. Training lesson plans for steam generator water level control, feedwater system,

emergency diesel systems, switchyard systems and reactor protection systems

11. Post trip review packages for reactor trips since 2008

12. Condition reports for common cause of crosscutting aspects related to corrective action

program and human performance

13. Planned and implemented corrective actions for common cause of crosscutting aspects

14. Procedures for work control processes

15. Quality Assurance audits of the corrective action program

16. Results of any benchmarking or external organization audits related to the 95002

inspection

17. Training and procedures related to NRC performance indicator reporting

- 2 -

Enclosure

18. Evaluation condition report related to traditional enforcement findings exceeding the

threshold

19. Condition reports related to equipment aging issues

20. Condition reports related to single point of vulnerability evaluations

21. Any long term equipment reliability evaluations and plans

Inspector Contact Information:

David Dumbacher

Senior Resident Inspector

573-676-3181

David.Dumbacher@nrc.gov

Mailing Address:

US NRC Resident Inspector Office

Attn: David Dumbacher

8201 NRC Road

Steedman, Mo 65077-1302