{{#Wiki_filter: | {{#Wiki_filter:September 20, 2013 | ||
==SUBJECT:== | ==SUBJECT:== | ||
| Line 28: | Line 28: | ||
Based on the results of this inspection, the NRC has determined that one Severity Level IV violation of NRC requirements occurred. The violation involves your failure to implement the cross contamination prevention and monitoring plan as required by the license. The violation is being treated as a Non-Cited Violation (NCV), consistent with Section 2.3.2 of the Enforcement Policy. The NCV is described in the subject inspection report. If you contest the violation or the significance of the NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the United States Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001, with copies to the Regional Administrator, Region IV; and the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001. | Based on the results of this inspection, the NRC has determined that one Severity Level IV violation of NRC requirements occurred. The violation involves your failure to implement the cross contamination prevention and monitoring plan as required by the license. The violation is being treated as a Non-Cited Violation (NCV), consistent with Section 2.3.2 of the Enforcement Policy. The NCV is described in the subject inspection report. If you contest the violation or the significance of the NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the United States Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001, with copies to the Regional Administrator, Region IV; and the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001. | ||
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response, should you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. To the extent possible, your response should not include any personal privacy, proprietary, information so that it can be made available to the Public without redaction. Should you have any questions concerning this inspection, please contact Dr. Robert Evans, Senior Health Physicist, at 817-200-1234 or the undersigned at 817-200-1191. | In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response, should you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. To the extent possible, your response should not include any personal privacy, proprietary, information so that it can be made available to the Public without redaction. | ||
UNITED STATES NUCLEAR REGULATORY COMMISSION RE G IO N I V 1600 EAST LAMAR BLVD ARLINGTON, TEXAS 76011-4511 Should you have any questions concerning this inspection, please contact Dr. Robert Evans, Senior Health Physicist, at 817-200-1234 or the undersigned at 817-200-1191. | |||
Sincerely, | Sincerely, | ||
/RA/ | /RA/ | ||
D. Blair Spitzberg, Ph.D., Chief Repository and Spent Fuel Safety Branch Division of Nuclear Materials Safety Docket: 050-00133 License: DPR-7 Enclosure: | |||
NRC Inspection Report 050-00133/13-010 cc w/encl: See next page | D. Blair Spitzberg, Ph.D., Chief Repository and Spent Fuel Safety Branch Division of Nuclear Materials Safety | ||
Docket: 050-00133 License: DPR-7 | |||
Enclosure: | |||
NRC Inspection Report 050-00133/13-010 | |||
cc w/encl: See next page | |||
cc list: | |||
Jennifer L. Post, Esq. | |||
Pacific Gas and Electric Company P.O. Box 7442 San Francisco, CA 94120 | |||
Loren Sharp, Director and Plant Manager Humboldt Bay Power Plant, PG&E 1000 King Salmon Avenue Eureka, CA 95505 | |||
Chairman Humboldt County Board of Supervisors County Courthouse 825 Fifth Street Eureka, CA 95501 | |||
Law Office of Linda J. Brown, Esq. | |||
999 5th Avenue, Suite 430 San Rafael, CA 94901 | |||
Regional Radiation Representative U.S. Environmental Protection Agency Region IX Office 75 Hawthorne Street San Francisco, CA 94105 | |||
Dr. James F. Davis, State Geologist Department of Conservation Division of Mines and Geology 801 K Street MS 12-30 Sacramento, CA 95814-3531 | |||
Director, Radiologic Health Branch State Department of Health Services P.O. Box 997414 (MS 7610) | |||
Sacramento, CA 95899-7474 | |||
Steven Hsu, M.S., Senior Health Physicist Radiological Assessment Unit Radioactive Material Licensing Section Radiologic Health Branch Dept. of Health Services, MS-7610 Sacramento, CA 95899-7414 | |||
Gretchen Dumas, Esq. | |||
Public Utilities Commission of the State of California 5066 State Building San Francisco, CA 94102 | |||
Director Energy Facilities Siting Division Energy Resources Conservation | |||
& Development Commission 1516 9th Street Sacramento, CA 95814 | |||
Redwood Alliance P.O. Box 293 Arcata, CA 95521 | |||
Dr. Robert B. Weisenmiller, Chair California Energy Commission 1516 Ninth Street (MS 34) | |||
Sacramento, CA 95814 | |||
California Public Utilities Commission 505 Van Ness, Room 4102 San Francisco, CA 94102 | |||
Deputy Attorney General State of California 110 West A Street, Suite 700 San Diego, CA 92101 | |||
}} | }} | ||
Latest revision as of 05:26, 11 January 2025
| ML13266A405 | |
| Person / Time | |
|---|---|
| Site: | Humboldt Bay |
| Issue date: | 09/20/2013 |
| From: | Spitzberg D NRC/RGN-IV/DNMS/RSFSB |
| To: | Halpin E Pacific Gas & Electric Co |
| Robert Evans | |
| References | |
| IR-13-010 | |
| Download: ML13266A405 (15) | |
Text
September 20, 2013
SUBJECT:
NRC INSPECTION REPORT 050-00133/13-010
Dear Mr. Halpin:
This letter refers to the inspection conducted on August 19-22, 2013, at the Humboldt Bay Power Plant, Unit 3 facility in Eureka, California. During this inspection, the U. S. Nuclear Regulatory Commission (NRC) staff examined activities conducted under your license as they relate to public health and safety to confirm compliance with the Commission's rules and regulations, and with the conditions of your license. Within these areas, the inspection consisted of selected examination of procedures and representative records, observations of activities, and interviews with personnel. The enclosed report presents the results of this inspection.
Based on the results of this inspection, the NRC has determined that one Severity Level IV violation of NRC requirements occurred. The violation involves your failure to implement the cross contamination prevention and monitoring plan as required by the license. The violation is being treated as a Non-Cited Violation (NCV), consistent with Section 2.3.2 of the Enforcement Policy. The NCV is described in the subject inspection report. If you contest the violation or the significance of the NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the United States Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001, with copies to the Regional Administrator, Region IV; and the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response, should you choose to provide one, will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. To the extent possible, your response should not include any personal privacy, proprietary, information so that it can be made available to the Public without redaction.
UNITED STATES NUCLEAR REGULATORY COMMISSION RE G IO N I V 1600 EAST LAMAR BLVD ARLINGTON, TEXAS 76011-4511 Should you have any questions concerning this inspection, please contact Dr. Robert Evans, Senior Health Physicist, at 817-200-1234 or the undersigned at 817-200-1191.
Sincerely,
/RA/
D. Blair Spitzberg, Ph.D., Chief Repository and Spent Fuel Safety Branch Division of Nuclear Materials Safety
Docket: 050-00133 License: DPR-7
Enclosure:
NRC Inspection Report 050-00133/13-010
cc w/encl: See next page
cc list:
Jennifer L. Post, Esq.
Pacific Gas and Electric Company P.O. Box 7442 San Francisco, CA 94120
Loren Sharp, Director and Plant Manager Humboldt Bay Power Plant, PG&E 1000 King Salmon Avenue Eureka, CA 95505
Chairman Humboldt County Board of Supervisors County Courthouse 825 Fifth Street Eureka, CA 95501
Law Office of Linda J. Brown, Esq.
999 5th Avenue, Suite 430 San Rafael, CA 94901
Regional Radiation Representative U.S. Environmental Protection Agency Region IX Office 75 Hawthorne Street San Francisco, CA 94105
Dr. James F. Davis, State Geologist Department of Conservation Division of Mines and Geology 801 K Street MS 12-30 Sacramento, CA 95814-3531
Director, Radiologic Health Branch State Department of Health Services P.O. Box 997414 (MS 7610)
Sacramento, CA 95899-7474
Steven Hsu, M.S., Senior Health Physicist Radiological Assessment Unit Radioactive Material Licensing Section Radiologic Health Branch Dept. of Health Services, MS-7610 Sacramento, CA 95899-7414
Gretchen Dumas, Esq.
Public Utilities Commission of the State of California 5066 State Building San Francisco, CA 94102
Director Energy Facilities Siting Division Energy Resources Conservation
& Development Commission 1516 9th Street Sacramento, CA 95814
Redwood Alliance P.O. Box 293 Arcata, CA 95521
Dr. Robert B. Weisenmiller, Chair California Energy Commission 1516 Ninth Street (MS 34)
Sacramento, CA 95814
California Public Utilities Commission 505 Van Ness, Room 4102 San Francisco, CA 94102
Deputy Attorney General State of California 110 West A Street, Suite 700 San Diego, CA 92101