WECTEC | WECTEC June 19, 20 I 7 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 I WECTEC LLC 3735 Glen Lake Drive Charlotte, NC 28208 Tel: +1 980 859 8000 10 CFR 21.21 | ||
==SUBJECT:== | ==SUBJECT:== | ||
| Line 23: | Line 23: | ||
Evaluation for reportability in accordance with 10 CFR Part 21 is not able to be completed within the 60-day evaluation period. It is currently expected that the evaluation of this condition will be completed by August 17, 2017. | Evaluation for reportability in accordance with 10 CFR Part 21 is not able to be completed within the 60-day evaluation period. It is currently expected that the evaluation of this condition will be completed by August 17, 2017. | ||
If you have any questions pertaining to this information, please contact Curtis Castell, Licensing Manager, at 980-859-6373. | If you have any questions pertaining to this information, please contact Curtis Castell, Licensing Manager, at 980-859-6373. | ||
Slncerely, | Slncerely, Qlfa. A7J~ | ||
Qlfa. A7J~ | Deborah A. Gustafson Vice President Project Services WECTECLLC cc: | ||
Deborah A. Gustafson Vice President Project Services WECTECLLC cc: | Regional Admini:Jtrator, USNRC, Region II}} | ||
Latest revision as of 11:40, 8 January 2025
| ML17251A841 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 06/19/2017 |
| From: | Gustafson D WECTEC LLC |
| To: | Document Control Desk, Office of New Reactors |
| References | |
| Download: ML17251A841 (1) | |
Text
.,
WECTEC June 19, 20 I 7 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 I WECTEC LLC 3735 Glen Lake Drive Charlotte, NC 28208 Tel: +1 980 859 8000 10 CFR 21.21
SUBJECT:
INTERIM 10 CFR PART 21 REPORT REGARDING A REACTOR COOLANT SYSTEM PIPE SPOOL FOR V. C. SUMMER UNIT 3 APIOOO PROJECT This letter provides an interim report in accordance with* 10 CFR 21.21 pertaining to one reactor coolant system pipe ~pool that is being supplied for V. C. Summer Unit 3 APlOOO project.
Based on information contained in a nonconfonnance & disposition (N&O) report, a weld on a weldolet fitting was found with lack of fusion on the root of the weld.
Evaluation for reportability in accordance with 10 CFR Part 21 is not able to be completed within the 60-day evaluation period. It is currently expected that the evaluation of this condition will be completed by August 17, 2017.
If you have any questions pertaining to this information, please contact Curtis Castell, Licensing Manager, at 980-859-6373.
Slncerely, Qlfa. A7J~
Deborah A. Gustafson Vice President Project Services WECTECLLC cc:
Regional Admini:Jtrator, USNRC, Region II