{{#Wiki_filter:Temporary Instruction (TI) 2515/191 Summary of Findings Inspection    Inspection          NRC Site     Region Report Date       Report        Documented                            Finding Summary of Issuance     ADAMS #           Findings One Green     Failure to ensure that the portable diesel equipment could Beaver Valley    I        5/3/18    ML18124A002 Finding    function within the required temperature range.
{{#Wiki_filter:Temporary Instruction (TI) 2515/191 Summary of Findings Page 1 of 3 Site Region Inspection Report Date of Issuance Inspection Report ADAMS #
Calvert Cliffs     I     5/30/17   ML17151A232           None       N/A Fitzpatrick       I     8/23/18   ML18240A368           None       N/A Ginna             I     12/2/16   ML16337A092           None       N/A Hope Creek         I     10/26/17   ML17300A141           None       N/A One Green     Failure to ensure that the portable diesel equipment could Indian Point      I      1/31/18    ML18031A358 Finding    function within the required temperature range.
NRC Documented Findings Finding Summary Beaver Valley I
Limerick           I     7/26/19   ML19207A083           None       N/A Millstone         I     11/28/16   ML16334A454           None       N/A Nine Mile Point   I     10/19/17   ML17293A057           None       N/A Oyster Creek       I     11/30/17   ML17334A756           None       N/A One Green Peach Bottom     I       3/5/19   ML19065A010                     Failure to maintain the SFPI battery functional.
5/3/18 ML18124A002 One Green Finding Failure to ensure that the portable diesel equipment could function within the required temperature range.
Finding Pilgrim           I       7/7/16   ML16189A066           None       N/A Salem             I     10/26/17   ML17300A058           None       N/A Seabrook         I       6/27/17   ML17180A060           None       N/A Susquehanna       I       8/6/19     ML19219A244           None       N/A Three Mile I       9/11/17   ML17255A131           None       N/A Island Browns Ferry     II       1/4/19   ML19015A302           None       N/A Brunswick         II     3/12/18   ML18071A151           None       N/A Catawba           II     11/16/17   ML17320A365           None       N/A Farley           II       8/6/18   ML18218A291           None       N/A Harris           II     1/11/17   ML17011A222           None       N/A Hatch             II     9/21/18   ML18264A038           None       N/A McGuire           II     8/30/16   ML16243A298           None       N/A North Anna       II     3/30/16   ML16091A340           None       N/A Oconee           II     8/28/18   ML18240A355           None       N/A Robinson         II     5/26/16   ML16147A118           None       N/A Sequoyah         II     4/18/17   ML17108A583           None       N/A St. Lucie         II     8/15/17   ML17227A031           None       N/A Page 1 of 3
Calvert Cliffs I
5/30/17 ML17151A232 None N/A Fitzpatrick I
8/23/18 ML18240A368 None N/A Ginna I
12/2/16 ML16337A092 None N/A Hope Creek I
10/26/17 ML17300A141 None N/A Indian Point I
1/31/18 ML18031A358 One Green Finding Failure to ensure that the portable diesel equipment could function within the required temperature range.
Limerick I
7/26/19 ML19207A083 None N/A Millstone I
11/28/16 ML16334A454 None N/A Nine Mile Point I
10/19/17 ML17293A057 None N/A Oyster Creek I
11/30/17 ML17334A756 None N/A Peach Bottom I
3/5/19 ML19065A010 One Green Finding Failure to maintain the SFPI battery functional.
Pilgrim I
7/7/16 ML16189A066 None N/A Salem I
10/26/17 ML17300A058 None N/A Seabrook I
6/27/17 ML17180A060 None N/A Susquehanna I
8/6/19 ML19219A244 None N/A Three Mile Island I
9/11/17 ML17255A131 None N/A Browns Ferry II 1/4/19 ML19015A302 None N/A Brunswick II 3/12/18 ML18071A151 None N/A Catawba II 11/16/17 ML17320A365 None N/A Farley II 8/6/18 ML18218A291 None N/A Harris II 1/11/17 ML17011A222 None N/A Hatch II 9/21/18 ML18264A038 None N/A McGuire II 8/30/16 ML16243A298 None N/A North Anna II 3/30/16 ML16091A340 None N/A Oconee II 8/28/18 ML18240A355 None N/A Robinson II 5/26/16 ML16147A118 None N/A Sequoyah II 4/18/17 ML17108A583 None N/A St. Lucie II 8/15/17 ML17227A031 None N/A  


Temporary Instruction (TI) 2515/191 Summary of Findings Inspection    Inspection          NRC Site     Region Report Date     Report        Documented                          Finding Summary of Issuance     ADAMS #           Findings Summer           II     4/10/18   ML18100A270         None       N/A Surry             II     4/11/17   ML17101A808         None       N/A Turkey Point     II     3/30/18   ML18089A127         None       N/A Vogtle           II   12/11/17   ML17345A892         None       N/A Watts Bar         II     6/22/15   ML15173A317         None       N/A Braidwood       III     2/2/18   ML18033A711         None       N/A Byron           III     9/20/17   ML17263B152         None       N/A Failure to provide adequate analysis to ensure that One Green Clinton          III    9/22/16    ML16266A301                    temporary hose can provide adequate diesel generator Finding cooling.
Temporary Instruction (TI) 2515/191 Summary of Findings Page 2 of 3 Site Region Inspection Report Date of Issuance Inspection Report ADAMS #
One Green Failure to maintain adequate room temperature to support Davis Besse      III    5/23/17    ML17143A342 Finding    FLEX operation.
NRC Documented Findings Finding Summary Summer II 4/10/18 ML18100A270 None N/A Surry II 4/11/17 ML17101A808 None N/A Turkey Point II 3/30/18 ML18089A127 None N/A Vogtle II 12/11/17 ML17345A892 None N/A Watts Bar II 6/22/15 ML15173A317 None N/A Braidwood III 2/2/18 ML18033A711 None N/A Byron III 9/20/17 ML17263B152 None N/A Clinton III 9/22/16 ML16266A301 One Green Finding Failure to provide adequate analysis to ensure that temporary hose can provide adequate diesel generator cooling.
DC Cook         III     6/7/16   ML16160A133         None       N/A Dresden         III     1/2/18   ML18002A344         None       N/A Duane Arnold     III   10/17/17   ML17292A738         None       N/A Fermi           III     2/23/17   ML17058A086         None       N/A Failure to ensure that sufficient electrical cabling was One Green LaSalle          III    11/26/18    ML18331A139                    available for one deployment path of the mitigating Finding strategy.
Davis Besse III 5/23/17 ML17143A342 One Green Finding Failure to maintain adequate room temperature to support FLEX operation.
Monticello       III     4/25/18   ML18115A064         None       N/A Palisades       III     12/2/06   ML16337A098         None       N/A Failure to establish replacement program or justify Two Green deviations for high-temperature rated hoses based on Perry            III    9/14/16    ML16258A452 Findings    vendor recommendations. Failure to establish periodic maintenance for communication equipment.
DC Cook III 6/7/16 ML16160A133 None N/A Dresden III 1/2/18 ML18002A344 None N/A Duane Arnold III 10/17/17 ML17292A738 None N/A Fermi III 2/23/17 ML17058A086 None N/A LaSalle III 11/26/18 ML18331A139 One Green Finding Failure to ensure that sufficient electrical cabling was available for one deployment path of the mitigating strategy.
Point Beach     III     6/16/17   ML17170A097         None       N/A Prairie Island   III     8/9/17   ML17222A208         None       N/A Quad Cities     III     5/17/19   ML19140A084         None       N/A Failure to assure that FLEX DG power supply connection Two Green design would be reliable following high wind events.
Monticello III 4/25/18 ML18115A064 None N/A Palisades III 12/2/06 ML16337A098 None N/A Perry III 9/14/16 ML16258A452 Two Green Findings Failure to establish replacement program or justify deviations for high-temperature rated hoses based on vendor recommendations. Failure to establish periodic maintenance for communication equipment.
ANO              IV      5/22/17    ML17143A032 Findings    Failure to provide adequate procedures to ensure implementation of the FLEX strategies.
Point Beach III 6/16/17 ML17170A097 None N/A Prairie Island III 8/9/17 ML17222A208 None N/A Quad Cities III 5/17/19 ML19140A084 None N/A ANO IV 5/22/17 ML17143A032 Two Green Findings Failure to assure that FLEX DG power supply connection design would be reliable following high wind events.
Page 2 of 3
Failure to provide adequate procedures to ensure implementation of the FLEX strategies.  


Temporary Instruction (TI) 2515/191 Summary of Findings Inspection    Inspection          NRC Site   Region Report Date     Report        Documented                            Finding Summary of Issuance     ADAMS #           Findings Callaway     IV     10/3/17   ML17277A053           None     N/A Columbia     IV     8/20/18   ML18232A432           None     N/A Comanche IV       7/9/17   ML17192A436           None     N/A Peak Failure to maintain the station satellite phones in locations One Green Cooper        IV      5/8/18    ML18128A074                    that would provide reasonable assurance that the phones Finding would remain available.
Temporary Instruction (TI) 2515/191 Summary of Findings Page 3 of 3 Site Region Inspection Report Date of Issuance Inspection Report ADAMS #
Diablo IV     1/24/18   ML18025A000           None     N/A Canyon Grand Gulf   IV     5/16/17   ML17136A174           None     N/A Palo Verde   IV       1/3/17   ML17004A044           None     N/A River Bend   IV       8/1/17   ML17214A822           None     N/A South Texas   IV     12/22/17   ML17354A799           None     N/A Two Green Findings   Failure to maintain availability of N+1 FLEX EDG. Notice (Notice of  of Violation issued.
NRC Documented Findings Finding Summary Callaway IV 10/3/17 ML17277A053 None N/A Columbia IV 8/20/18 ML18232A432 None N/A Comanche Peak IV 7/9/17 ML17192A436 None N/A Cooper IV 5/8/18 ML18128A074 One Green Finding Failure to maintain the station satellite phones in locations that would provide reasonable assurance that the phones would remain available.
Waterford    IV      7/20/18    ML18201A492        Violation also issued  Failure to consider internal flooding assumptions could with one    result in unavailability of FLEX core cooling pump.
Diablo Canyon IV 1/24/18 ML18025A000 None N/A Grand Gulf IV 5/16/17 ML17136A174 None N/A Palo Verde IV 1/3/17 ML17004A044 None N/A River Bend IV 8/1/17 ML17214A822 None N/A South Texas IV 12/22/17 ML17354A799 None N/A Waterford IV 7/20/18 ML18201A492 Two Green Findings (Notice of Violation also issued with one finding)
finding)
Failure to maintain availability of N+1 FLEX EDG. Notice of Violation issued.
Wolf Creek   IV     3/23/18   ML18082A107           None     N/A Page 3 of 3}}
Failure to consider internal flooding assumptions could result in unavailability of FLEX core cooling pump.
Wolf Creek IV 3/23/18 ML18082A107 None N/A}}

Latest revision as of 00:54, 3 January 2025

Ti 2515-191 Summary of Findings
ML19280A038
Person / Time
Site: Beaver Valley
Issue date: 10/22/2019
From: Aron Lewin
NRC/NRR/DIRS/IRIB
To: Thomas Hipschman
NRC/NRR/DIRS/IRIB
Lewin A, 415-2259, NRR/DIRS
Shared Package
ML19276G075 List:
References
Download: ML19280A038 (3)


Text

Temporary Instruction (TI) 2515/191 Summary of Findings Page 1 of 3 Site Region Inspection Report Date of Issuance Inspection Report ADAMS #

NRC Documented Findings Finding Summary Beaver Valley I

5/3/18 ML18124A002 One Green Finding Failure to ensure that the portable diesel equipment could function within the required temperature range.

Calvert Cliffs I

5/30/17 ML17151A232 None N/A Fitzpatrick I

8/23/18 ML18240A368 None N/A Ginna I

12/2/16 ML16337A092 None N/A Hope Creek I

10/26/17 ML17300A141 None N/A Indian Point I

1/31/18 ML18031A358 One Green Finding Failure to ensure that the portable diesel equipment could function within the required temperature range.

Limerick I

7/26/19 ML19207A083 None N/A Millstone I

11/28/16 ML16334A454 None N/A Nine Mile Point I

10/19/17 ML17293A057 None N/A Oyster Creek I

11/30/17 ML17334A756 None N/A Peach Bottom I

3/5/19 ML19065A010 One Green Finding Failure to maintain the SFPI battery functional.

Pilgrim I

7/7/16 ML16189A066 None N/A Salem I

10/26/17 ML17300A058 None N/A Seabrook I

6/27/17 ML17180A060 None N/A Susquehanna I

8/6/19 ML19219A244 None N/A Three Mile Island I

9/11/17 ML17255A131 None N/A Browns Ferry II 1/4/19 ML19015A302 None N/A Brunswick II 3/12/18 ML18071A151 None N/A Catawba II 11/16/17 ML17320A365 None N/A Farley II 8/6/18 ML18218A291 None N/A Harris II 1/11/17 ML17011A222 None N/A Hatch II 9/21/18 ML18264A038 None N/A McGuire II 8/30/16 ML16243A298 None N/A North Anna II 3/30/16 ML16091A340 None N/A Oconee II 8/28/18 ML18240A355 None N/A Robinson II 5/26/16 ML16147A118 None N/A Sequoyah II 4/18/17 ML17108A583 None N/A St. Lucie II 8/15/17 ML17227A031 None N/A

Temporary Instruction (TI) 2515/191 Summary of Findings Page 2 of 3 Site Region Inspection Report Date of Issuance Inspection Report ADAMS #

NRC Documented Findings Finding Summary Summer II 4/10/18 ML18100A270 None N/A Surry II 4/11/17 ML17101A808 None N/A Turkey Point II 3/30/18 ML18089A127 None N/A Vogtle II 12/11/17 ML17345A892 None N/A Watts Bar II 6/22/15 ML15173A317 None N/A Braidwood III 2/2/18 ML18033A711 None N/A Byron III 9/20/17 ML17263B152 None N/A Clinton III 9/22/16 ML16266A301 One Green Finding Failure to provide adequate analysis to ensure that temporary hose can provide adequate diesel generator cooling.

Davis Besse III 5/23/17 ML17143A342 One Green Finding Failure to maintain adequate room temperature to support FLEX operation.

DC Cook III 6/7/16 ML16160A133 None N/A Dresden III 1/2/18 ML18002A344 None N/A Duane Arnold III 10/17/17 ML17292A738 None N/A Fermi III 2/23/17 ML17058A086 None N/A LaSalle III 11/26/18 ML18331A139 One Green Finding Failure to ensure that sufficient electrical cabling was available for one deployment path of the mitigating strategy.

Monticello III 4/25/18 ML18115A064 None N/A Palisades III 12/2/06 ML16337A098 None N/A Perry III 9/14/16 ML16258A452 Two Green Findings Failure to establish replacement program or justify deviations for high-temperature rated hoses based on vendor recommendations. Failure to establish periodic maintenance for communication equipment.

Point Beach III 6/16/17 ML17170A097 None N/A Prairie Island III 8/9/17 ML17222A208 None N/A Quad Cities III 5/17/19 ML19140A084 None N/A ANO IV 5/22/17 ML17143A032 Two Green Findings Failure to assure that FLEX DG power supply connection design would be reliable following high wind events.

Failure to provide adequate procedures to ensure implementation of the FLEX strategies.

Temporary Instruction (TI) 2515/191 Summary of Findings Page 3 of 3 Site Region Inspection Report Date of Issuance Inspection Report ADAMS #

NRC Documented Findings Finding Summary Callaway IV 10/3/17 ML17277A053 None N/A Columbia IV 8/20/18 ML18232A432 None N/A Comanche Peak IV 7/9/17 ML17192A436 None N/A Cooper IV 5/8/18 ML18128A074 One Green Finding Failure to maintain the station satellite phones in locations that would provide reasonable assurance that the phones would remain available.

Diablo Canyon IV 1/24/18 ML18025A000 None N/A Grand Gulf IV 5/16/17 ML17136A174 None N/A Palo Verde IV 1/3/17 ML17004A044 None N/A River Bend IV 8/1/17 ML17214A822 None N/A South Texas IV 12/22/17 ML17354A799 None N/A Waterford IV 7/20/18 ML18201A492 Two Green Findings (Notice of Violation also issued with one finding)

Failure to maintain availability of N+1 FLEX EDG. Notice of Violation issued.

Failure to consider internal flooding assumptions could result in unavailability of FLEX core cooling pump.

Wolf Creek IV 3/23/18 ML18082A107 None N/A