DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel assembly containing a maximum of 236 fuel rods cicd with Zircaloy-4. Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 grams uranium. The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235. Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.1 weight percent U-235.                                             I CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element assemblies.
DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel assembly containing a maximum of 236 fuel rods cicd with Zircaloy-4.
Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 grams uranium.
The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235.
Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.1 weight percent U-235.
I CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element assemblies.
5.4 REACTOR COOLANT SYSTEM f
5.4 REACTOR COOLANT SYSTEM f
DESIGN PRESSURE AND TEMPERATURE
DESIGN PRESSURE AND TEMPERATURE
    '5.4.1 The Reactor Coolant System is designed and shall be maintained:
'5.4.1 The Reactor Coolant System is designed and shall be maintained:
                                          ~
~
: a. In accordance with the code requirements specified in Section 5.2 of the FSAR with allowance for normal degradation pursuant of the applicable Surveillance Requirements,
a.
: b. For a pressure of 2500 psia, and
In accordance with the code requirements specified in Section 5.2 of the FSAR with allowance for normal degradation pursuant of the applicable Surveillance Requirements, b.
: c. For a temperature of 650'F, except for the pressurizer and surge line which is 700*F.
For a pressure of 2500 psia, and c.
For a temperature of 650'F, except for the pressurizer and surge line which is 700*F.
VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11,800
VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11,800
      +600, -0 cubic feet- at a nominal T,yg of 582.1*F.
+600, -0 cubic feet-at a nominal T,yg of 582.1*F.
5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.
5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.
l WATERFORD - UNIT 3                     5-5                     AMENDMENT NO. 7,##
WATERFORD - UNIT 3 5-5 AMENDMENT NO. 7,##
9502010314 950127 PDR ADOCK 050003B2 P               PDR
9502010314 950127 PDR ADOCK 050003B2 P
PDR


(---
(---
1 9
1 9
* y I ~ '.
y I ~ '.
c NPF-38-163 ATTACHMENT II
c NPF-38-163 ATTACHMENT II


,+                         .        - , . _ _ - - .-- ..    --      .  -.    .-      .              -      . .
,+
31 DESIGN FEATlRES i
31 DESIGN FEATlRES i
        '5.3   REACTOR CORE                                                                                       i FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel. assembly containing a maximum of 236 fuel rods clad with Zircaloy 4. Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 1830 grams uranium.         l     .,
'5.3 REACTOR CORE i
The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235.
FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel. assembly containing a maximum of 236 fuel rods clad with Zircaloy 4.
Reload fuel shall be similar in physical design to the initial core loadingg-and Assemblies               .
Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 1830 grams uranium.
shall have a maximum enrichment of Art 4.9 weight percent U-235 provided they contain sufficient fixed poisons to meet the final storage requirements described in section 5.6.
l The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235.
CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element                     f assemblies.
Reload fuel shall be similar in physical design to the initial core loadingg-and Assemblies shall have a maximum enrichment of Art 4.9 weight percent U-235 provided they contain sufficient fixed poisons to meet the final storage requirements described in section 5.6.
CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element f
assemblies.
5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE
5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE
                                                                                                                  )
)
5.4.1 The Reactor Coolant System is designed and shall be maintained-                                     !
5.4.1 The Reactor Coolant System is designed and shall be maintained-a.
: a.         In accordance with the code requirements specified in Section 5.2 of the FSAR         l with allowance for normal degradation pursuant of the applicable Surveillance         j Requirements,                                                                         j l
In accordance with the code requirements specified in Section 5.2 of the FSAR l
: b.         For a pressure of 2500 psia, and                                                       1 i
with allowance for normal degradation pursuant of the applicable Surveillance j
: c.         For a temperature of 650F, except for the pressurizer and surge line which is         I l
Requirements, j
l b.
For a pressure of 2500 psia, and 1
i c.
For a temperature of 650F, except for the pressurizer and surge line which is I
700*F.
700*F.
                                                                      .                                            l VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11.800 +600, -0 cubic feet at a nominal Tavg of 582.1*F.                                                                 i 5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.
l VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11.800 +600, -0 cubic feet at a nominal Tavg of 582.1*F.
WATERFORD - UNIT 3                               55                         AMENDMENT NO.,44
i 5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.
WATERFORD - UNIT 3 55 AMENDMENT NO.,44


.a '
.a i
i NPF-38-163 ATTACHMENT III}}
NPF-38-163 ATTACHMENT III}}

Latest revision as of 00:43, 15 December 2024

Proposed Tech Specs 5.3.1,increasing Max Enrichment for Spent Fuel Pool & Containment Temporary Storage Rack from 4.1 to 4.9 Weight Percent U-235 When Fuel Assemblies Contain Fixed Poisons
ML20078F092
Person / Time
Site: Waterford Entergy icon.png
Issue date: 01/27/1995
From:
ENTERGY OPERATIONS, INC.
To:
Shared Package
ML20078F090 List:
References
NUDOCS 9502010314
Download: ML20078F092 (4)


Text

-

DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel assembly containing a maximum of 236 fuel rods cicd with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 grams uranium.

The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and shall have a maximum enrichment of 4.1 weight percent U-235.

I CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element assemblies.

5.4 REACTOR COOLANT SYSTEM f

DESIGN PRESSURE AND TEMPERATURE

'5.4.1 The Reactor Coolant System is designed and shall be maintained:

~

a.

In accordance with the code requirements specified in Section 5.2 of the FSAR with allowance for normal degradation pursuant of the applicable Surveillance Requirements, b.

For a pressure of 2500 psia, and c.

For a temperature of 650'F, except for the pressurizer and surge line which is 700*F.

VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11,800

+600, -0 cubic feet-at a nominal T,yg of 582.1*F.

5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.

WATERFORD - UNIT 3 5-5 AMENDMENT NO. 7,##

9502010314 950127 PDR ADOCK 050003B2 P

PDR

(---

1 9

y I ~ '.

c NPF-38-163 ATTACHMENT II

,+

31 DESIGN FEATlRES i

'5.3 REACTOR CORE i

FUEL ASSEMBLIES 5.3.1 The reactor core shall contain 217 fuel assemblies with each fuel. assembly containing a maximum of 236 fuel rods clad with Zircaloy 4.

Each fuel rod shall have a nominal active fuel length of 150 inches and contain a nominal total weight of 1807 1830 grams uranium.

l The initial core loading shall have a maximum enrichment of 2.91 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loadingg-and Assemblies shall have a maximum enrichment of Art 4.9 weight percent U-235 provided they contain sufficient fixed poisons to meet the final storage requirements described in section 5.6.

CONTROL ELEMENT ASSEMBLIES 5.3.2 The reactor core shall contain 83 full-length and 8 part-length control element f

assemblies.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE

)

5.4.1 The Reactor Coolant System is designed and shall be maintained-a.

In accordance with the code requirements specified in Section 5.2 of the FSAR l

with allowance for normal degradation pursuant of the applicable Surveillance j

Requirements, j

l b.

For a pressure of 2500 psia, and 1

i c.

For a temperature of 650F, except for the pressurizer and surge line which is I

700*F.

l VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 11.800 +600, -0 cubic feet at a nominal Tavg of 582.1*F.

i 5.5 METEOROLOGICAL TOWERS LOCATION 5.5.1 The primary and backup meteorological towers shall be located as shown on Figure 5.1-1.

WATERFORD - UNIT 3 55 AMENDMENT NO.,44

.a i

NPF-38-163 ATTACHMENT III