{{#Wiki_filter: | {{#Wiki_filter:Aiiieren Callaway Plant MISSOURI June 12, 2024 ULNRC- 06884 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 1 0CfR72.2 1 2(b)(2) | ||
Ladies and Gentlemen: | |||
DOCKET NUMBERS 50-483 AND 72-1045 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO. | |||
RENEWED FACILITY OPERATING LICENSE NPF-30 INDEPENDENT SPENT FUEL STORAGE INSTALLATION REGISTRATION OF DRY SPENT FUEL STORAGE CANISTER HGMPC0002 Pursuant to 10 CFR 72.212(b)(2), Union Electric Company d/b/a Ameren Missouri, the Licensee for Callaway Plant, is registering the use of a dry spent fuel storage cask to store spent fuel under a 10 CFR Part 72 general license at the Callaway Plant Independent Spent Fuel Storage Installation (ISFSI). The information below is provided for multi-purpose canister (MPC) number HGMPC0002, used to store spent fuel within cavity enclosure container (CEC) number HGUMAX0002, beginning on May 23, 2024. | |||
The following information is provided as required by 1 0 CFR 72.2 12(b)(2): | |||
HGUMAX0002 | Licensee Name: | ||
Union Electric Company Licensee Address: | |||
Callaway Nuclear Plant 83 1 5 County Road 459 Steedman, MO 65077 Reactor License No: | |||
NPF-30 Docket Nos.: | |||
50-483 and 72-1045 (1SFSI) 83 15 County Road 459 Steedman, MO 65077 AmerenMissouri.com | |||
ULNRC-06884 June 12, 2024 Page 2 of 4 Contact Name and | |||
==Title:== | |||
Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing Cask Certificate No.: | |||
Certificate ofCompliance No. 1040, Amendment 0, April 6, 2015 Cask Model: | |||
HI-STORM UMAX Canister Storage System Cask Identification Nos. : | |||
Multi-Purpose Canister (MPC) Identification No. : HGMPC0002 Cavity Enclosure Container (CEC) Identification No.: | |||
HGUMAX0002 This letter does not contain new commitments. Should you have questions regarding this submittal, please contact Mr. Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing, at 3 14-225-1905. | |||
Sincerely, Todd A. Witt Director, Nuclear Engineering Design and Regulatory Affairs | |||
ULNRC-068 84 June 12, 2024 Page 3 of 4 cc: | |||
Mr. John Monninger Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1 600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U. S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. M. Chawla Project Manager, Callaway Plant Office ofNuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop O8B1A Washington, DC 20555-0001 Director Division of Spent Fuel Management Office ofNuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 | |||
ULNRC-06884 June 12, 2024 Page 4 of 4 Index and send hardcopy to QA File A160.0761 Hardcopy: | |||
Certrec Corporation 6500 West Freway, Suite 400 Fort Worth, TX 76116 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.) | |||
Electronic distribution for the following can be made via Responses and Reports ULNRC Distribution: | |||
F. M. Diya K. C. Scott W. A. Witt T. A. Witt J. G. Beck T. B. Elwood S. A. Gaydos G. N. Klein C. J. Ehmke NSRB Secretary STARS Regulatory Affairs Mr. Jay Silberg (Pillsbury Winthrop Shaw Pittman LLP)}} | |||
Latest revision as of 18:00, 24 November 2024
| ML24164A073 | |
| Person / Time | |
|---|---|
| Site: | Callaway, HI-STORM 100 |
| Issue date: | 06/12/2024 |
| From: | Witt T Ameren Missouri, Union Electric Co |
| To: | Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| ULNRC-06884 | |
| Download: ML24164A073 (1) | |
Text
Aiiieren Callaway Plant MISSOURI June 12, 2024 ULNRC- 06884 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 1 0CfR72.2 1 2(b)(2)
Ladies and Gentlemen:
DOCKET NUMBERS 50-483 AND 72-1045 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.
RENEWED FACILITY OPERATING LICENSE NPF-30 INDEPENDENT SPENT FUEL STORAGE INSTALLATION REGISTRATION OF DRY SPENT FUEL STORAGE CANISTER HGMPC0002 Pursuant to 10 CFR 72.212(b)(2), Union Electric Company d/b/a Ameren Missouri, the Licensee for Callaway Plant, is registering the use of a dry spent fuel storage cask to store spent fuel under a 10 CFR Part 72 general license at the Callaway Plant Independent Spent Fuel Storage Installation (ISFSI). The information below is provided for multi-purpose canister (MPC) number HGMPC0002, used to store spent fuel within cavity enclosure container (CEC) number HGUMAX0002, beginning on May 23, 2024.
The following information is provided as required by 1 0 CFR 72.2 12(b)(2):
Licensee Name:
Union Electric Company Licensee Address:
Callaway Nuclear Plant 83 1 5 County Road 459 Steedman, MO 65077 Reactor License No:
NPF-30 Docket Nos.:
50-483 and 72-1045 (1SFSI) 83 15 County Road 459 Steedman, MO 65077 AmerenMissouri.com
ULNRC-06884 June 12, 2024 Page 2 of 4 Contact Name and
Title:
Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing Cask Certificate No.:
Certificate ofCompliance No. 1040, Amendment 0, April 6, 2015 Cask Model:
HI-STORM UMAX Canister Storage System Cask Identification Nos. :
Multi-Purpose Canister (MPC) Identification No. : HGMPC0002 Cavity Enclosure Container (CEC) Identification No.:
HGUMAX0002 This letter does not contain new commitments. Should you have questions regarding this submittal, please contact Mr. Tom Elwood, Supervising Engineer, Regulatory Affairs and Licensing, at 3 14-225-1905.
Sincerely, Todd A. Witt Director, Nuclear Engineering Design and Regulatory Affairs
ULNRC-068 84 June 12, 2024 Page 3 of 4 cc:
Mr. John Monninger Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1 600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U. S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. M. Chawla Project Manager, Callaway Plant Office ofNuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop O8B1A Washington, DC 20555-0001 Director Division of Spent Fuel Management Office ofNuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
ULNRC-06884 June 12, 2024 Page 4 of 4 Index and send hardcopy to QA File A160.0761 Hardcopy:
Certrec Corporation 6500 West Freway, Suite 400 Fort Worth, TX 76116 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)
Electronic distribution for the following can be made via Responses and Reports ULNRC Distribution:
F. M. Diya K. C. Scott W. A. Witt T. A. Witt J. G. Beck T. B. Elwood S. A. Gaydos G. N. Klein C. J. Ehmke NSRB Secretary STARS Regulatory Affairs Mr. Jay Silberg (Pillsbury Winthrop Shaw Pittman LLP)