{{#Wiki_filter:DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                         TABLE 9-1 Revision 36 Page 1 of 1 HISTORIC SERVICE WATER SYSTEM FLOW REQUIREMENTS (gpm)
{{#Wiki_filter:DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-1 Revision 36 Page 1 of 1
Component Name Critical Service Water Header CCW Heat Exchangers                                          <6000 Control Room Air Conditioning                                  12(1)
Instrument Air Compressors (C-2A, C-2C)                          16 Alternate to Replenish SFP(3)                                    40 Noncritical Service Water Header(2)
Instrument Air Compressor C-2B Aftercooler                        8 Circ Water and Intake Basin Chlorinator                          50 Aux Building Addition Air Conditioning Unit                    28.8 Ventilation Equipment Room Air Cooling Unit                    28.8 Radwaste Area Compressor                                          20 Auxiliary Building Condensing Unit                              130 FWP Air Compressor                                              65.2 CD Bldg Boiler Sample (measured) Cooler                          1.6 Plant Htg Condensate Return Heat Exchanger (E-924)            100(4)
Radiation Monitors                                              10 NOTES:
(1)-    Only one unit (or set of coolers) is operated at one time.
(2)-    Flows listed here are from original Bechtel figures and have not been verified.
(3)-    Provisions exist to allow the Service Water System to replenish the Spent Fuel Pool (SFP)
(4)-    Flow is temperature controlled.


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                            TABLE 9-2 Revision 36 Page 1 of 2 SERVICE WATER SYSTEM CONSTRUCTION OF COMPONENTS
HISTORIC SERVICE WATER SYSTEM FLOW REQUIREMENTS (gpm)
: 1. Service Water Pumps Type                          Vertical Turbine With Water Lubrication Number                        3 Material Bowls                        Cast Iron or Cast Steel or Cast Stainless Steel Discharge Head              Carbon Steel Bowl Shaft                  416 SS Line Shaft                  1045 CS or 416 SS Discharge Column            Carbon Steel Impeller                    Bronze or Stainless Steel Motor                          350 hp, 3 Ph, 60 Hz, 2,300 V Codes                          Standards of Hydraulic Institute, NEMA, ASA and ASTM


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                  TABLE 9-2 Revision 36 Page 2 of 2 SERVICE WATER SYSTEM CONSTRUCTION OF COMPONENTS
Component Name
: 2. Basket Strainers Type                                Simplex Multi-Basket Number                              3 Screen Mesh                          3/16 in Perforation Material Body                              Cast Steel Baskets                            304 SS
: 3. Piping, Fittings and Valves Material                            Carbon Steel, Bronze, Stainless Steel, or Cast Iron & Ductile Iron (non-safety related only)
Piping and Fittings(a)              2-1/2 in and Larger - Butt- Welded Except at Flanged Equipment(a) 2 in and Smaller - Socket Welded Except at Flanged Equipment or Threaded Valves(a)                            2-1/2 in and Larger - Butt-Welded 150 lb(a) 2 in and Smaller - Socket Welded 600 lb or Threaded 200 lb or Flanged 150 lb Class Code                                ASA B31.1-1955 ASA B16.5-1961 (a) These are considered to be classified as flanged equipment.


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                        TABLE 9-3 Revision 36 Page 1 of 3 REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS
Critical Service Water Header
: 1. Shield Cooling Coils Length (Each Coil)                    Approx 24 ft Spacing of Coils                      9 in Center-to-Center Number of Coil Sections in Each Set    3 Coil Diameter                          3/4 in Material                              Seamless Carbon Steel Code                                  ASA B31.1
: 2. Shield Cooling Pumps Type                                  Horizontal Centrifugal With Mechanical Seals Number                                2 Material Case                                  Cast Iron Impeller                              CD4MCU (Stainless Steel)
Shaft                                Stainless Steel (Solid)
Motor                                  7.5 hp, 3 Ph, 60 Hz, 460 V, 1750 r/min Codes                                  Standards of Hydraulic Institute, NEMA, ASA and ASTM


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                         TABLE 9-3 Revision 36 Page 2 of 3 REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS
CCW Heat Exchangers <6000
: 3. Shield Cooling Heat Exchanger Type                                   Horizontal Counterflow, Shell With Straight Tubes Rolled Into Fixed Tube Sheets Number                                 1 Material Shell                                 Carbon Steel Tubes                                 Admiralty Channels                             Carbon Steel Tube Sheets                           Aluminum Bronze Codes                                 ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW-2 (a);
 
Control Room Air Conditioning 12(1)
Instrument Air Compressors (C-2A, C-2C) 16 Alternate to Replenish SFP(3) 40
 
Noncritical Service Water Header(2)
 
Instrument Air Compressor C-2B Aftercooler 8
 
Circ Water and Intake Basin Chlorinator 50
 
Aux Building Addition Air Conditioning Unit 28.8 Ventilation Equipment Room Air Cooling Unit 28.8 Radwaste Area Compressor 20 Auxiliary Building Condensing Unit 130 FWP Air Compressor 65.2
 
CD Bldg Boiler Sample (measured) Cooler 1.6 Plant Htg Condensate Return Heat Exchanger (E-924) 100(4)
Radiation Monitors 10
 
NOTES:
 
(1)- Only one unit (or set of coolers) is operated at one time.
 
(2)- Flows listed here are from original Bechtel figures and have not been verified.
 
(3)- Provisions exist to allow the Service Water System to replenish the Spent Fuel Pool (SFP)
 
(4)- Flow is temperature controlled.
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-2 Revision 36 Page 1 of 2
 
SERVICE WATER SYSTEM CONSTRUCTION OF COMPONENTS
: 1. Service Water Pumps
 
Type Vertical Turbine With Water Lubrication
 
Number 3
 
Material
 
Bowls Cast Iron or Cast Steel or Cast Stainless Steel
 
Discharge Head Carbon Steel
 
Bowl Shaft 416 SS
 
Line Shaft 1045 CS or 416 SS
 
Discharge Column Carbon Steel
 
Impeller Bronze or Stainless Steel
 
Motor 350 hp, 3 Ph, 60 Hz, 2,300 V
 
Codes Standards of Hydraulic Institute, NEMA, ASA and ASTM
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-2 Revision 36 Page 2 of 2
 
SERVICE WATER SYSTEM CONSTRUCTION OF COMPONENTS
: 2. Basket Strainers
 
Type Simplex Multi-Basket
 
Number 3
 
Screen Mesh 3/16 in Perforation
 
Material
 
Body Cast Steel
 
Baskets 304 SS
: 3. Piping, Fittings and Valves
 
Material Carbon Steel, Bronze, Stainless Steel, or Cast Iron & Ductile Iron (non-safety related only)
 
Piping and Fittings(a) 2-1/2 in and Larger - Butt-Welded Except at Flanged Equipment(a)
 
2 in and Smaller - Socket Welded Except at Flanged Equipment or Threaded
 
Valves(a) 2-1/2 in and Larger - Butt-Welded 150 lb(a)
 
2 in and Smaller - Socket Welded 600 lb or Threaded 200 lb or Flanged 150 lb Class
 
Code ASA B31.1-1955 ASA B16.5-1961
 
(a) These are considered to be classified as flanged equipment.
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-3 Revision 36 Page 1 of 3
 
REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS
: 1. Shield Cooling Coils
 
Length (Each Coil) Approx 24 ft
 
Spacing of Coils 9 in Center-to-Center
 
Number of Coil Sections in Each Set 3
 
Coil Diameter 3/4 in
 
Material Seamless Carbon Steel
 
Code ASA B31.1
: 2. Shield Cooling Pumps
 
Type Horizontal Centrifugal With Mechanical Seals
 
Number 2
 
Material
 
Case Cast Iron
 
Impeller CD4MCU (Stainless Steel)
 
Shaft Stainless Steel (Solid)
 
Motor 7.5 hp, 3 Ph, 60 Hz, 460 V, 1750 r/min
 
Codes Standards of Hydraulic Institute, NEMA, ASA and ASTM
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-3 Revision 36 Page 2 of 3
 
REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS
: 3. Shield Cooling Heat Exchanger
 
Type Horizontal Counterflow, Shell With Straight Tubes Rolled Into Fixed Tube Sheets
 
Number 1
 
Material
 
Shell Carbon Steel
 
Tubes Admiralty
 
Channels Carbon Steel
 
Tube Sheets Aluminum Bronze
 
Codes ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW-2 (a);
TEMA Class C
TEMA Class C
: 4. Shield Cooling Surge Tank Type                                   Vertical Number                                 1 Material                               Carbon Steel Code                                   ASME B&PV Code Section III, Class C and ASME B&PV Code, Section VIII, Par UW-2 (a)
: 4. Shield Cooling Surge Tank
 
Type Vertical
 
Number 1
 
Material Carbon Steel
 
Code ASME B&PV Code Section III, Class C and ASME B&PV Code, Section VIII, Par UW-2 (a)
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-3 Revision 36 Page 3 of 3
 
REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS
: 5. Piping, Fittings and Valves
 
Material Seamless Carbon Steel
 
Not Embedded in Embedded In Concrete Concrete Construction
 
Pipe, 2-1/2 in and Larger Butt-Welded Except None at Flanged Equipment
 
Pipe, 2 in and Smaller Screwed Except at Socket Flanged Equipment Welded
 
Valves, 2-1/2 in and Larger Cast Iron, None Flanged 125#
 
Valves, 2 in and Smaller Bronze, Screwed None 200# and Carbon Steel, flanged 150#
 
Code ASA B31.1
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-4 Revision 36 Page 1 of 1


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                          TABLE 9-3 Revision 36 Page 3 of 3 REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS
COMPONENT COOLING SYSTEM HEAT LOADS (x 106 Btu/hr)
: 5. Piping, Fittings and Valves Material                                  Seamless Carbon Steel Not Embedded in      Embedded In Concrete          Concrete Construction Pipe, 2-1/2 in and Larger          Butt-Welded Except    None at Flanged Equipment Pipe, 2 in and Smaller              Screwed Except at      Socket Flanged Equipment      Welded Valves, 2-1/2 in and Larger        Cast Iron,            None Flanged 125#
Valves, 2 in and Smaller            Bronze, Screwed        None 200# and Carbon Steel, flanged 150#
Code                                ASA B31.1


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                              TABLE 9-4 Revision 36 Page 1 of 1 COMPONENT COOLING SYSTEM HEAT LOADS (x 106 Btu/hr)
Component and (Number)
Component and (Number)
Spent Fuel Pool HX (1)            9.2 Waste Gas Compressors (3)        0.01 Total                            9.21


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                       TABLE 9-5 Revision 36 Page 1 of 2 COMPONENT COOLING WATER SYSTEM CONSTRUCTION OF COMPONENTS
Spent Fuel Pool HX (1) 9.2
: 1. Component Cooling Pumps Type                                 Horizontal Centrifugal With Mechanical Seals Number                               3 Material Case                               Carbon Steel Impeller                           Bronze Shaft                               Alloy Steel Motor                               300 hp, 3 Ph, 60 Hz, 2,300 V Codes                               Standards of Hydraulic Institute, NEMA, ASA and ASTM
 
: 2. Component Cooling Heat Exchangers Type                                 Horizontal, Counterflow, Shell Straight Tubes, Tubes Rolled Into Tube Sheets Number                               2 Original Heat Transfer Area (Each)   7,840 ft2 Material Shell Side                          Carbon Steel, Firebox Quality Tube Side                          Admiralty Tube Sheet                          Carbon Steel With Aluminum Bronze Overlay Codes                                ASME B&PV Code, Section III, Class C, 1965 and ASME B&PV Code, Section VIII, Par UW-2 (a); TEMA Class C
Waste Gas Compressors (3) 0.01
 
Total 9.21 DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-5 Revision 36 Page 1 of 2
 
COMPONENT COOLING WATER SYSTEM CONSTRUCTION OF COMPONENTS
: 1. Component Cooling Pumps
 
Type Horizontal Centrifugal With Mechanical Seals
 
Number 3
 
Material
 
Case Carbon Steel
 
Impeller Bronze
 
Shaft Alloy Steel
 
Motor 300 hp, 3 Ph, 60 Hz, 2,300 V
 
Codes Standards of Hydraulic Institute, NEMA, ASA and ASTM
: 2. Component Cooling Heat Exchangers
 
Type Horizontal, Counterflow, Shell Straight Tubes, Tubes Rolled Into Tube Sheets
 
Number 2
 
Original Heat Transfer Area (Each) 7,840 ft2
 
Material


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                              TABLE 9-5 Revision 36 Page 2 of 2 COMPONENT COOLING WATER SYSTEM CONSTRUCTION OF COMPONENTS
Shell Side Carbon Steel, Firebox Quality
: 3. Surge Tank Type                                        Vertical Number                                      1 Material                                    Carbon Steel Code                                        ASME B&PV Code, Section III, Class C, 1965
: 4. Piping, Fittings and Valves Piping Material                            Carbon Steel, Seamless and Seam Welded (Seam Weld 100% Radiographed)
Inside Outside Containment        Containment Construction Pipe, 2-1/2 in and Larger  Butt-Welded Except        Butt-Welded at Flanged Equipment,      Except at 10% of Circumferen-        Flanged tial Welds Examined        Equipment by Radiography Pipe, 2 in and Smaller    Socket Welded              Screwed Except-Except Flanged            at Flanged Equipment                  Equipment Valves (Except Butterfly), Carbon Steel,              Cast Iron, 2-1/2 in and Larger        Butt Weld                  Flanged Ends, 150#                Ends, 125#
Butterfly Valves,          Carbon Steel,              Carbon Steel, 2-1/2 in and Larger        Flanged Ends, 150#        Flanged Ends, 150#
Valves, 2 in and Smaller  Carbon Steel, Socket      Bronze, Welded Ends,              Screwed 600#                      Ends, 200#
Code                        ASA B31.1-1955            ASA B31.1-1955 ASA B16.5-1961            ASA B16.5-1961


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                            TABLE 9-6 Revision 36 Page 1 of 1 COMPONENT COOLING SYSTEM REQUIRED FLOW RATES (GPM)
Tube Side Admiralty
Component and (Number)      Normal Spent Fuel Pool HX (1) ***  650 Waste Gas Compressors (3)      6 Vacuum Degasifier Pump Seal    8 Water Cooler (1)
Total                        664


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                              TABLE 9-7 Revision 36 Page 1 of 4 SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Tube Sheet Carbon Steel With Aluminum Bronze Overlay
: 1. Fuel Pool Cooling Pumps Type                                  Horizontal Centrifugal With Mechanical Seals Number                                2 Capacity (Each)                        1,700 gpm TDH                                    64 ft Temperature Transient                  Designed To Withstand an Increase from 60qF to 212qF in 5 Seconds Material                              Stainless Steel Motor                                  40 hp, 460 V, 60 Hz 3 Ph, Code                                  Motor, NEMA; Pump, Standards of Hydraulic Institute
: 2. Spent Fuel Pool Cooling Heat Exchange Unit Type                                  Horizontal Counterflow, With Straight Tubes Rolled Into Tube Sheets Number                                2 Shells in Series Original Duty (Total)                  23 x 106 Btu/h Original Heat Transfer Area            4,080 ft2 Component Cooling Water Temperature: In/Out                    90/115qF Spent Fuel Cooling Water Temperature: In/Out                    125/110qF Temperature Transient                  Designed To Withstand an Increase From 60qF to 212qF in 5 Seconds


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                           TABLE 9-7 Revision 36 Page 2 of 4 SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS Material Shells                             Carbon Steel Tubes                               Stainless Steel Tube Sheets                         Stainless Steel With SS 308L Weld Overlay Codes                               ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW2 (a);
Codes ASME B&PV Code, Section III, Class C, 1965 and ASME B&PV Code, Section VIII, Par UW-2 (a); TEMA Class C DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-5 Revision 36 Page 2 of 2
 
COMPONENT COOLING WATER SYSTEM CONSTRUCTION OF COMPONENTS
: 3. Surge Tank
 
Type Vertical
 
Number 1
 
Material Carbon Steel
 
Code ASME B&PV Code, Section III, Class C, 1965
: 4. Piping, Fittings and Valves
 
Piping Material Carbon Steel, Seamless and Seam Welded (Seam Weld 100% Radiographed)
 
Inside Outside Containment Containment
 
Construction
 
Pipe, 2-1/2 in and Larger Butt-Welded Except Butt-Welded at Flanged Equipment, Except at 10% of Circumferen-Flanged tial Welds Examined Equipment by Radiography
 
Pipe, 2 in and Smaller Socket Welded Screwed Except-Except Flanged at Flanged Equipment Equipment
 
Valves (Except Butterfly), Carbon Steel, Cast Iron, 2-1/2 in and Larger Butt Weld Flanged Ends, 150# Ends, 125#
 
Butterfly Valves, Carbon Steel, Carbon Steel, 2-1/2 in and Larger Flanged Ends, 150# Flanged Ends, 150#
 
Valves, 2 in and Smaller Carbon Steel, Socket Bronze, Welded Ends, Screwed 600# Ends, 200#
 
Code ASA B31.1-1955 ASA B31.1-1955 ASA B16.5-1961 ASA B16.5-1961
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-6 Revision 36 Page 1 of 1
 
COMPONENT COOLING SYSTEM REQUIRED FLOW RATES (GPM)
 
Component and (Number) Normal
 
Spent Fuel Pool HX (1) *** 650
 
Waste Gas Compressors (3) 6
 
Vacuum Degasifier Pump Seal 8 Water Cooler (1)
 
Total 664
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 1 of 4
 
SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: 1. Fuel Pool Cooling Pumps
 
Type Horizontal Centrifugal With Mechanical Seals
 
Number 2
 
Capacity (Each) 1,700 gpm
 
TDH 64 ft
 
Temperature Transient Designed To Withstand an Increase from 60qF to 212qF in 5 Seconds
 
Material Stainless Steel
 
Motor 40 hp, 460 V, 60 Hz 3 Ph,
 
Code Motor, NEMA; Pump, Standards of Hydraulic Institute
: 2. Spent Fuel Pool Cooling Heat Exchange Unit
 
Type Horizontal Counterflow, With Straight Tubes Rolled Into Tube Sheets
 
Number 2 Shells in Series
 
Original Duty (Total) 23 x 106 Btu/h
 
Original Heat Transfer Area 4,080 ft2
 
Component Cooling Water Temperature: In/Out 90/115qF
 
Spent Fuel Cooling Water Temperature: In/Out 125/110qF
 
Temperature Transient Designed To Withstand an Increase From 60qF to 212qF in 5 Seconds DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 2 of 4
 
SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
 
Material
 
Shells Carbon Steel
 
Tubes Stainless Steel
 
Tube Sheets Stainless Steel With SS 308L Weld Overlay
 
Codes ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW2 (a);
TEMA Class C
TEMA Class C
: 3. Fuel Pool Recirculation Booster Pump Type                                 Horizontal Centrifugal With Mechanical Seals Number                               1 Capacity                             160 gpm TDH                                  160 ft Temperature Transient                Designed To Withstand Increase From 60qF to 212qF in 5 Seconds Material                            Type 316 Stainless Steel Motor                                15 hp, 3 Ph, 60 Hz 460 V Code                                Motor, NEMA; Pump, Standards of Hydraulic Institute
: 3. Fuel Pool Recirculation Booster Pump
 
Type Horizontal Centrifugal With Mechanical Seals
 
Number 1
 
Capacity 160 gpm


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                          TABLE 9-7 Revision 36 Page 3 of 4 SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
TDH 160 ft
: 4. Fuel Pool Filter Type                                Cartridge With Replaceable Filter Element Number                              1 Design Flow                        150 gpm Design Pressure                    200 psig Design Temperature                  250qF Temperature Transient              Designed for Increase From 60qF to 212qF in 5 Seconds Filter Rating                      25 Microns Nominal Material                            Stainless Steel Codes                              ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW2 (a)
: 5. Fuel Pool Demineralizer Type                                Mixed Bed Number                              1 Design Flow                        150 gpm Design Pressure                    200 psig Design Temperature                  220qF Temperature Transient              Design for an Increase From 60qF to 212qF in 5 Seconds Resin                              Equivalent Capacity Mixture of Nuclear Grade Cation and Anion


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                          TABLE 9-7 Revision 36 Page 4 of 4 SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS Material                              Type 304 Stainless Steel for Vessel and Integral Parts Codes                                ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW2 (a)
Temperature Transient Designed To Withstand Increase From 60qF to 212qF in 5 Seconds
: 6. Piping, Fittings and Valves Material                              Stainless Steel Design Pressure                      125 psig Design Temperature                   150qF Joints, 2 in and Larger              ButtWelded Except at Flanged Equipment 1-1/2 in and Smaller                Socket Welded Except at Flanged Equipment Valves, 2 in and Larger              Stainless Steel, Butt Weld Ends, 150#
11/2 in and Smaller                  Stainless Steel, Socket Weld Ends, 150#
Butterflies, All Sizes              Stainless Steel Flanged, 150#
Code                                  ASA B31.1 Welds                                100% Radiographically Checked
: 7. Spent Fuel Pool Volume of Empty SFP Cavity            21,885 ft3 Volume of Empty North Tilt Pit Cavity 4,095 ft3


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                               TABLE 9-8 Revision 36 Page 1 of 5 INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Material Type 316 Stainless Steel
 
Motor 15 hp, 3 Ph, 60 Hz 460 V
 
Code Motor, NEMA; Pump, Standards of Hydraulic Institute
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 3 of 4
 
SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: 4. Fuel Pool Filter
 
Type Cartridge With Replaceable Filter Element
 
Number 1
 
Design Flow 150 gpm
 
Design Pressure 200 psig
 
Design Temperature 250qF
 
Temperature Transient Designed for Increase From 60qF to 212qF in 5 Seconds
 
Filter Rating 25 Microns Nominal
 
Material Stainless Steel
 
Codes ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW2 (a)
: 5. Fuel Pool Demineralizer
 
Type Mixed Bed
 
Number 1
 
Design Flow 150 gpm
 
Design Pressure 200 psig
 
Design Temperature 220qF
 
Temperature Transient Design for an Increase From 60qF to 212qF in 5 Seconds
 
Resin Equivalent Capacity Mixture of Nuclear Grade Cation and Anion DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 4 of 4
 
SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
 
Material Type 304 Stainless Steel for Vessel and Integral Parts
 
Codes ASME B&PV Code, Section III, Class C and ASME B&PV Code, Section VIII, Par UW2 (a)
: 6. Piping, Fittings and Valves
 
Material Stainless Steel
 
Design Pressure 125 psig
 
Design Temperature 150qF
 
Joints, 2 in and Larger ButtWelded Except at Flanged Equipment
 
1-1/2 in and Smaller Socket Welded Except at Flanged Equipment
 
Valves, 2 in and Larger Stainless Steel, Butt Weld Ends, 150#
 
11/2 in and Smaller Stainless Steel, Socket Weld Ends, 150#
 
Butterflies, All Sizes Stainless Steel Flanged, 150#
 
Code ASA B31.1
 
Welds 100% Radiographically Checked
: 7. Spent Fuel Pool
 
Volume of Empty SFP Cavity 21,885 ft3
 
Volume of Empty North Tilt Pit Cavity 4,095 ft3 DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 1 of 5
 
INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: 1. Instrument Air System
: 1. Instrument Air System
: a. Air Compressors Type                             Rotary Screw, Oil Free, Air Cooled Number                           3 Design Capacity (Each)           288 scfm Design Pressure                 125 psig Main Motor (Compressor)         75 hp, 3 Ph, 60 Hz, 460 V Fan Motor                       5 hp, 3 Ph, 60 Hz, 460 V Code                             Motor, NEMA
: a. Air Compressors
 
Type Rotary Screw, Oil Free, Air Cooled
 
Number 3
 
Design Capacity (Each) 288 scfm
 
Design Pressure 125 psig
 
Main Motor (Compressor) 75 hp, 3 Ph, 60 Hz, 460 V
 
Fan Motor 5 hp, 3 Ph, 60 Hz, 460 V
 
Code Motor, NEMA
: b. Aftercoolers
: b. Aftercoolers
: 1. Type                       Shell and Tube Number                      3 (1 per Compressor)
: 1. Type Shell and Tube
: 2. Type                        Cooling Coil Number                      3 (1 per Compressor - onboard)
: c. Air Receivers Type                            Vertical Number                          3 Design Pressure                  125 psig Capacity                        57 ft3 Code                            ASME B&PV Code, Section VIII


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                               TABLE 9-8 Revision 36 Page 2 of 5 INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Number 3 (1 per Compressor)
: d. Air Dryer Type                               Silica Gel Absorbent, Electric Heater Reactivated Number                             1 Capacity                           205 scfm Outlet Moisture Content With Saturated Air Inlet           -40&deg;F Dew Point at 100 psig Code                               ASME B&PV Code, Section VIII
: 2. Type Cooling Coil
: e. Piping and Valves Upstream of Dryer                 Carbon Steel Piping and CI, or Bronze Valves Downstream of Dryer               Copper Piping and Bronze or Stainless Steel Valves Except at Containment Penetration and at Isolation Valves (Carbon Steel)
 
Code                               ASA B31.1
Number 3 (1 per Compressor - onboard)
: c. Air Receivers
 
Type Vertical
 
Number 3
 
Design Pressure 125 psig
 
Capacity 57 ft3
 
Code ASME B&PV Code, Section VIII
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 2 of 5
 
INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: d. Air Dryer
 
Type Silica Gel Absorbent, Electric Heater Reactivated
 
Number 1
 
Capacity 205 scfm Outlet Moisture Content With Saturated Air Inlet -40&deg;F Dew Point at 100 psig
 
Code ASME B&PV Code, Section VIII
: e. Piping and Valves
 
Upstream of Dryer Carbon Steel Piping and CI, or Bronze Valves
 
Downstream of Dryer Copper Piping and Bronze or Stainless Steel Valves Except at Containment Penetration and at Isolation Valves (Carbon Steel)
 
Code ASA B31.1
: 2. High Pressure Air System
: 2. High Pressure Air System
: a. Air Compressors Type                               Single Acting, Air Cooled Number                             3 Design Capacity (Each)             22.3 scfm Design Pressure                   325 psig Motor                             10 hp, 440 V, 3 Phase Code                               Motor, NEMA
: a. Air Compressors
 
Type Single Acting, Air Cooled
 
Number 3
 
Design Capacity (Each) 22.3 scfm
 
Design Pressure 325 psig
 
Motor 10 hp, 440 V, 3 Phase
 
Code Motor, NEMA
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 3 of 5
 
INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: b. Air Dryer
 
Type Desiccant
 
Number 3 (1 per Compressor)
 
Capacity (Each) 35 scfm
 
Dewpoint -40 &deg;F at 350 psig
 
Code ASME B&PV Code, Section VIII
: c. Air Receivers
 
Type Horizontal
 
Number 3 (1 per Compressor)
 
Design Pressure 350 psig
 
Capacity 60 ft3
 
Code ASME B&PV Code, Section VIII
: d. Aftercoolers
 
Number 3 (1 per Compressor)


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                        TABLE 9-8 Revision 36 Page 3 of 5 INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Type Air Cooled
: b. Air Dryer Type                           Desiccant Number                        3 (1 per Compressor)
: e. Piping
Capacity (Each)                35 scfm Dewpoint                      -40 &deg;F at 350 psig Code                          ASME B&PV Code, Section VIII
: c. Air Receivers Type                          Horizontal Number                        3 (1 per Compressor)
Design Pressure                350 psig Capacity                      60 ft3 Code                          ASME B&PV Code, Section VIII
: d. Aftercoolers Number                        3 (1 per Compressor)
Type                          Air Cooled
: e. Piping Material                      Carbon Steel Code                          ASA B31.1 (Seismic Class I Supported From Receivers to Operators on Engineered Safe-guards Systems)


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                               TABLE 9-8 Revision 36 Page 4 of 5 INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Material Carbon Steel
 
Code ASA B31.1 (Seismic Class I Supported From Receivers to Operators on Engineered Safe-guards Systems)
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 4 of 5
 
INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: 3. Feedwater Purity Air System
: 3. Feedwater Purity Air System
: a. Air Compressors Type                                  Two stage air screw, oil free Number                                2 Design Capacity (Each)                297 scfm Design Pressure                      117 psi Motor                                75 hp, 460 V, 3 Phase Air Dryer (Integral to Compressor)
: a. Air Compressors
Type                            Refrigerant Power Consumption (at full load) 1.6 kW Pressure                        102 psig Dew Point                        37.4&deg;F @ 68&deg;F/100% RH
: c. Aftercooler Number                                2 Type                                  Air Cooled
: d. Receiver Type                                  Vertical Number                                1 Design Pressure                      150 psig Design Temp                          100&deg;F Capacity                              1060 gal Code                                  ASME B&PV Code, Section VIII


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                             TABLE 9-8 Revision 36 Page 5 of 5 INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Type Two stage air screw, oil free
 
Number 2
 
Design Capacity (Each) 297 scfm
 
Design Pressure 117 psi
 
Motor 75 hp, 460 V, 3 Phase
 
Air Dryer (Integral to Compressor)
 
Type Refrigerant
 
Power Consumption (at full load) 1.6 kW
 
Pressure 102 psig
 
Dew Point 37.4&deg;F @ 68&deg;F/100% RH
: c. Aftercooler
 
Number 2
 
Type Air Cooled
: d. Receiver
 
Type Vertical
 
Number 1
 
Design Pressure 150 psig
 
Design Temp 100&deg;F
 
Capacity 1060 gal
 
Code ASME B&PV Code, Section VIII
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 5 of 5
 
INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: 4. Nitrogen Backup Stations
: 4. Nitrogen Backup Stations
: a. Nitrogen Bottles Pressure (nominal)               2400 psig
: a. Nitrogen Bottles
 
Pressure (nominal) 2400 psig
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-9 Revision 36 Page 1 of 2
 
EFFECT OF LOSS OF AIR TO AIR-OPERATED VALVES
 
Position Safety (a) After Loss No Valve Description Position of Air
 
Service Water System
 
CV-0821 CCW Heat Exchanger Temp Control C C CV-0822 CCW Heat Exchanger Temp Control C C CV-0823 Component Cool HX Dischg O O CV-0824 Return From Containment Coolers O/C O CV-0825 Eng Safe Room Cooler Supply O O CV-0826 Component Cool HX Dischg O O CV-0844 Critical Service Wtr Header Iso O O CV-0845 Critical Service Wtr Header Iso O O CV-0846 Critical Service Water Header Cross Connect O O CV-0847 Supply to Containment Coolers O O CV-0857 Critical Service Water Header Cross Connect O O CV-0861 8" Return From Cont Coolers O O CV-0862 Containment Cooler Supply O O CV-0864 8" Return From Cont Coolers O O CV-0865 Containment Cooler Supply O O CV-0867 8" Return From Cont Coolers O O CV-0869 Containment Cooler Supply C C CV-0870 Containment Cooler Supply O O CV-0873 8" Return From Cont Coolers O O CV-0876 Diesel Generator Cool Supply O O CV-0877 Diesel Generator Cool Supply O O CV-0878 Eng Safe Room Cooler Supply O O CV-0879 Backup Cool Safeguards Pumps C C CV-0880 Backup Cool Safeguards Pumps C C CV-0884 Diesel Generator Cool Supply O O CV-0885 Diesel Generator Cool Supply O O CV-1318 Service Water Pump Header Iso O O CV-1319 Service Water Pump Header Iso O O CV-1359 Noncritical Service Water Header Isolation C C CV-1655 Control Room HVAC Service Water O O CV-1656 Control Room HVAC Service Water O O
 
(a) Safety position is maintained in this table, but safety is no longer applicable as none of the systems are safety-related.
O Open C Closed DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-9 Revision 36 Page 2 of 2
 
EFFECT OF LOSS OF AIR TO AIR-OPERATED VALVES
 
Position Safety (a) After Loss No Valve Description Position of Air
 
Component Cooling System
 
CV-0915 Comp Cool Surge Tank Vent C C CV-0944 Supply to Radwaste Evaporator C C CV-0944A Supply to Spent Fuel HX C C CV-0945 Supply to Comp Cool HX O O CV-0946 Supply to Comp Cool HX O O CV-0977B Return From Radwaste Evaporator C C
 
Radioactive Waste Treatment System
 
CV-1001 Primary System Drain Tank Recirc C C CV-1002 Primary System Drain Tank Outlet C C CV-1004 Degasifier Pump Discharge C C CV-1007 Primary System Drain Tank Outlet C C CV-1036 Pump P-70 Inlet C C CV-1037 Clean Waste Tank Recirc C C CV-1038 Pump P-70 Inlet C C CV-1044 Pump P-69 A/B Suction C C CV-1045 Pump P-69 A/B Suction C C CV-1064 Clean Waste Tank Vent C C CV-1065 Clean Waste Tank Vent C C CV-1101 Waste Gas Surge Tank Vent C C CV-1102 Waste Gas Surge Tank Vent C C CV-1103 Containment Sump Drain C C CV-1104 Containment Sump Drain C C
 
(a) Safety position is maintained in this table, but safety is no longer applicable as none of the systems are safety-related.
O Open C Closed
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-11 Revision 36 Page 1 of 3
 
FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
: 1. Fire Pump, Motor Driven
 
Type Vertical Turbine
 
Number 1
 
Capacity 1,500 gpm
 
Discharge Pressure 125 psig
 
Material
 
Discharge Head Cast Iron
 
Impeller Bronze
 
Motor 150 hp, 460 V, 3 Ph, 60 Hz
 
Codes Underwriters Lab Label Motor, NEMA; Pump, Standards of Hydraulic Institute
: 2. Fire Pump, Diesel Engine Driven
 
Type Vertical Turbine
 
Number 2
 
Capacity 1,500 gpm
 
Discharge Pressure 125 psig
 
Material
 
Discharge Head Cast Iron
 
Impeller Bronze
 
Gear Drive Reduction Ratio 1:1, 200 hp Rating
 
Diesel Engine 150 hp
 
Codes Underwriters Lab Label Diesel Engine, NEMA; Pump, Standards of Hydraulic Institute DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-11 Revision 36 Page 2 of 3


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                          TABLE 9-9 Revision 36 Page 1 of 2 EFFECT OF LOSS OF AIR TO AIR-OPERATED VALVES Position Safety (a)  After Loss No                Valve Description                            Position        of Air Service Water System CV-0821          CCW Heat Exchanger Temp Control                      C            C CV-0822          CCW Heat Exchanger Temp Control                      C            C CV-0823          Component Cool HX Dischg                              O              O CV-0824          Return From Containment Coolers                      O/C            O CV-0825          Eng Safe Room Cooler Supply                          O              O CV-0826          Component Cool HX Dischg                              O              O CV-0844          Critical Service Wtr Header Iso                      O              O CV-0845          Critical Service Wtr Header Iso                      O              O CV-0846          Critical Service Water Header Cross Connect          O              O CV-0847          Supply to Containment Coolers                        O            O CV-0857          Critical Service Water Header Cross Connect          O              O CV-0861          8" Return From Cont Coolers                          O              O CV-0862          Containment Cooler Supply                            O              O CV-0864          8" Return From Cont Coolers                          O              O CV-0865          Containment Cooler Supply                            O              O CV-0867          8" Return From Cont Coolers                          O              O CV-0869          Containment Cooler Supply                            C            C CV-0870          Containment Cooler Supply                            O              O CV-0873          8" Return From Cont Coolers                          O              O CV-0876          Diesel Generator Cool Supply                          O              O CV-0877          Diesel Generator Cool Supply                          O              O CV-0878          Eng Safe Room Cooler Supply                          O              O CV-0879          Backup Cool Safeguards Pumps                          C            C CV-0880          Backup Cool Safeguards Pumps                          C            C CV-0884          Diesel Generator Cool Supply                          O              O CV-0885          Diesel Generator Cool Supply                          O              O CV-1318          Service Water Pump Header Iso                        O              O CV-1319          Service Water Pump Header Iso                        O              O CV-1359          Noncritical Service Water Header Isolation            C            C CV-1655          Control Room HVAC Service Water                      O              O CV-1656          Control Room HVAC Service Water                      O              O (a) Safety position is maintained in this table, but safety is no longer applicable as none of the systems are safety-related.
FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
O Open C    Closed
: 3. Fire System Jockey Pump


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                          TABLE 9-9 Revision 36 Page 2 of 2 EFFECT OF LOSS OF AIR TO AIR-OPERATED VALVES Position Safety (a)  After Loss No                Valve Description                              Position        of Air Component Cooling System CV-0915          Comp Cool Surge Tank Vent                            C            C CV-0944          Supply to Radwaste Evaporator                        C            C CV-0944A        Supply to Spent Fuel HX                              C              C CV-0945          Supply to Comp Cool HX                                O              O CV-0946          Supply to Comp Cool HX                                O              O CV-0977B        Return From Radwaste Evaporator                      C            C Radioactive Waste Treatment System CV-1001          Primary System Drain Tank Recirc                      C            C CV-1002          Primary System Drain Tank Outlet                      C            C CV-1004          Degasifier Pump Discharge                            C            C CV-1007          Primary System Drain Tank Outlet                      C            C CV-1036          Pump P-70 Inlet                                      C            C CV-1037          Clean Waste Tank Recirc                              C            C CV-1038          Pump P-70 Inlet                                      C            C CV-1044          Pump P-69 A/B Suction                                C            C CV-1045          Pump P-69 A/B Suction                                C            C CV-1064          Clean Waste Tank Vent                                C            C CV-1065          Clean Waste Tank Vent                                C            C CV-1101          Waste Gas Surge Tank Vent                            C            C CV-1102          Waste Gas Surge Tank Vent                            C            C CV-1103          Containment Sump Drain                                C            C CV-1104          Containment Sump Drain                                C            C (a) Safety position is maintained in this table, but safety is no longer applicable as none of the systems are safety-related.
Type Vertical Turbine
O Open C    Closed


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                        TABLE 9-10 Revision 36 Page 1 of 3 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION                      DETECTORS TYPE OF DETECTORS
Number 1
: 1. Cable Spreading Rm, Col M-28                              1        Water Flow Sw (WFS-2B)
: 2. 1-D Switchgear Rm, Col G-28; Col G-22; Col G-22            4        Water Flow Sw (WFS-2B1, WFS-2B2, WFS-2B3, WFS-2D)
: 3. 1-1 Diesel Generator Rm , Col J-28                          1      Water Flow Sw (WFS-2G1)
: 4. 1-2 Diesel Generator Rm , Col M-28                          1      Water Flow Sw (WFS-2G2)
: 5. Turbine Bldg 590', Col H-9                                1        Water Flow Sw (WFS-2I)
: 6. Control Room (Room 325)                                    8            Smoke
: 7. Control Room Adj Offices Rms 324 & 320                    2            Smoke
: 8. Cable Spreading, Room 224                                  13            Smoke
: 9. Refueling & Spent Fuel Area, Rm 220                        4            Smoke
: 10. 1-D Switchgear Rm, Rm 223                                  9            Smoke
: 11. North Penetration, Rm 332                                  2            Smoke


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                          TABLE 9-10 Revision 36 Page 2 of 3 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION                        DETECTORS TYPE OF DETECTORS
Capacity 50 gpm
: 12. 1-C Switchgear Rm, Rm 116A                                    2          Smoke
: 13. Southwest Cable Penetration, Rm 250                            2          Smoke
: 14. Engineered Safeguards Panel Area, Rm 121                      3          Smoke
: 15. Stairwell Outside Engineered Safeguards Panel Area, Rm 016    2          Smoke
: 16. Component Cooling Pump, Rm 123                                2          Smoke
: 17. Safeguard Area, Rm 4                                          3          Smoke
: 18. Safeguard Area, Rm 5                                          2          Smoke
: 19. Corridor 106 on 590' Elevation, Rm 106                        6          Smoke
: 20. Charging Pump, Rm 104                                          2          Smoke
: 21. Containment, Interior North Penetration Area, Rm 332          3          Smoke
: 22. Containment, Interior SW Penetration Area, Rm 141, 250        3          Smoke
: 23. Containment Instrument Air Room                                3          Smoke
: 24. Auxiliary Feed Pump Room 570' Level of Turbine Bldg,          3          Smoke Rm 007
: 25. Battery Rm 225A                                                1          Smoke


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                            TABLE 9-10 Revision 36 Page 3 of 3 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION                        DETECTORS TYPE OF DETECTORS
Discharge Pressure 117 psig nominal
: 26. Battery Rm 225B                                              1            Smoke
: 27. HVAC Equipment Rooms & Chase:                                              Smoke West Mechanical Equipment Room 300                        1            Smoke East Mechanical Equipment Room 300A                      1            Smoke Duct Chase, Rm 300B                                      1
: 28. Air Handling Unit V-95 & V-96 Inlet Ducts, Rm 300, 300A      2            Smoke
: 29. Electrical Equipment Room, Rm 725                            6            Smoke
: 30. Technical Support Center, Rm 320A                            2            Smoke
: 31. Intake Structure, Room 136                                    11          Ultraviolet
: 32. Charging Pump Rooms 104, 104A, and 104B                      1        Water Flow Sw (WFS-2J)
: 33. Diesel - Driven Auxiliary Feedwater Pump Shed                  2      Fire & Flame Det.
1      Water Flow Sw


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                          TABLE 9-11 Revision 36 Page 1 of 3 FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Material
: 1. Fire Pump, Motor Driven Type                                  Vertical Turbine Number                                1 Capacity                              1,500 gpm Discharge Pressure                    125 psig Material Discharge Head                Cast Iron Impeller                      Bronze Motor                                150 hp, 460 V, 3 Ph, 60 Hz Codes                                Underwriters Lab Label Motor, NEMA; Pump, Standards of Hydraulic Institute
: 2. Fire Pump, Diesel Engine Driven Type                                  Vertical Turbine Number                                2 Capacity                              1,500 gpm Discharge Pressure                    125 psig Material Discharge Head                Cast Iron Impeller                      Bronze Gear Drive                            Reduction Ratio 1:1, 200 hp Rating Diesel Engine                        150 hp Codes                                Underwriters Lab Label Diesel Engine, NEMA; Pump, Standards of Hydraulic Institute


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                            TABLE 9-11 Revision 36 Page 2 of 3 FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Discharge Head Fabricated Steel
: 3. Fire System Jockey Pump Type                                    Vertical Turbine Number                                  1 Capacity                                50 gpm Discharge Pressure                      117 psig nominal Material Discharge Head                   Fabricated Steel Impellers                       Bronze Motor                                   7-1/2 hp, 460 V, 3 PH, 60 Hz Codes                                   Motor, NEMA; Pump Standards of Hydraulic Institute
 
Impellers Bronze
 
Motor 7-1/2 hp, 460 V, 3 PH, 60 Hz
 
Codes Motor, NEMA; Pump Standards of Hydraulic Institute
: 4. Piping, Fittings and Valves
: 4. Piping, Fittings and Valves
: a. To Auxiliary Feedwater Pump Suction Header and Critical Service Waterlines Material                         Seamless Carbon Steel Design Pressure                 125 psig Design Temperature               100&deg;F Construction                     Butt-Welded Except at Flanged Equipment Valves                           Carbon Steel, Butt-Weld Ends, 150#,
: a. To Auxiliary Feedwater Pump Suction Header and Critical Service Waterlines
 
Material Seamless Carbon Steel
 
Design Pressure 125 psig
 
Design Temperature 100&deg;F
 
Construction Butt-Welded Except at Flanged Equipment
 
Valves Carbon Steel, Butt-Weld Ends, 150#,
or Cast Iron, Flanged End, 175#,
or Cast Iron, Flanged End, 175#,
Underwriters lab Label
Underwriters lab Label


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                             TABLE 9-11 Revision 36 Page 3 of 3 FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-11 Revision 36 Page 3 of 3
: b. To Spent Fuel Pool Blind Flange and Normal Fire Protection Service Underground         Aboveground Material     Original-     Cast Iron         Carbon Steel (150# Class)
 
Replacement- Ductile Iron (350# Class)
FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS
Design Pressure             150 psig           125 psig Design Temperature           100&deg;F             100&deg;F Construction Original-       Mechanical Joint   Butt-Welded Except at Flanged Equipment Replacement- Push-on Joint Valves       Original-     Cast Iron,         Cast Iron, Flanged Mechanical Joint, End, 175#,
: b. To Spent Fuel Pool Blind Flange and Normal Fire Protection Service
175#, Underwriters Underwriters Lab Lab Label         Label Replacement- Ductile Iron, Mechanical Joint, 250#, UL Listed, FM Approved
 
Underground Aboveground
 
Material Original-Cast Iron Carbon Steel (150# Class)
 
Replacement-Ductile Iron (350# Class)
 
Design Pressure 150 psig 125 psig
 
Design Temperature 100&deg;F 100&deg;F
 
Construction Original-Mechanical Joint Butt-Welded Except at Flanged Equipment
 
Replacement-Push-on Joint
 
Valves Original-Cast Iron, Cast Iron, Flanged Mechanical Joint, End, 175#,
175#, Underwriters Underwriters Lab Lab Label Label
 
Replacement-Ductile Iron, Mechanical Joint, 250#, UL Listed, FM Approved
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 1 of 4


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                            TABLE 9-12 Revision 36 Page 1 of 4 AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
: 1. Motor-Driven Auxiliary Feedwater Pump (P-8A)
: 1. Motor-Driven Auxiliary Feedwater Pump (P-8A)
Type                           Horizontal Centrifugal, With Packed Glands Number                         1 Material Case                         4.6% Chrome Alloy Steel Impeller                     Bronze Shaft                         11%-13% Chrome Alloy Steel Motor                         450 hp, 3 Ph, 60 Hz, 2,300 V Codes                         Motor, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965
 
Type Horizontal Centrifugal, With Packed Glands
 
Number 1
 
Material
 
Case 4.6% Chrome Alloy Steel
 
Impeller Bronze
 
Shaft 11%-13% Chrome Alloy Steel
 
Motor 450 hp, 3 Ph, 60 Hz, 2,300 V
 
Codes Motor, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965
: 2. Turbine-Driven Auxiliary Feedwater Pump (P-8B)
: 2. Turbine-Driven Auxiliary Feedwater Pump (P-8B)
Type                          Horizontal Centrifugal, With Packed Glands Number                        1 Material Case                          4.6% Chrome Alloy Steel Impeller                      Bronze Shaft                        11%-13% Chrome Alloy Steel Turbine                        Single Stage, Axial Flow, Exhaust to Atmosphere, 450 hp Codes                          Turbine, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                               TABLE 9-12 Revision 36 Page 2 of 4 AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
Type Horizontal Centrifugal, With Packed Glands
 
Number 1
 
Material
 
Case 4.6% Chrome Alloy Steel
 
Impeller Bronze
 
Shaft 11%-13% Chrome Alloy Steel
 
Turbine Single Stage, Axial Flow, Exhaust to Atmosphere, 450 hp
 
Codes Turbine, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 2 of 4
 
AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
: 3. Motor Driven Auxiliary Feedwater Pump (P-8C)
: 3. Motor Driven Auxiliary Feedwater Pump (P-8C)
Type                             Horizontal Centrifugal, With Mechanical Seals Number                           1 Material Case                           18 Cr, 8 Ni Stainless Steel Impeller                       12 Cr Stainless Steel Shaft                           12 Cr, 0.6 Mo Stainless Steel Motor                           400 hp, 3 Ph, 60 Hz, 2,300 V Codes                           Motor, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965
 
Type Horizontal Centrifugal, With Mechanical Seals
 
Number 1
 
Material
 
Case 18 Cr, 8 Ni Stainless Steel
 
Impeller 12 Cr Stainless Steel
 
Shaft 12 Cr, 0.6 Mo Stainless Steel
 
Motor 400 hp, 3 Ph, 60 Hz, 2,300 V
 
Codes Motor, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965
: 4. Piping and Valves for P-8A, P-8B, and P-8C
: 4. Piping and Valves for P-8A, P-8B, and P-8C
: a. Pump Suction Underground               Aboveground Material                     304 Stainless Steel     Carbon Steel Construction                 Welded Except at Flanged Equipment Connections Valves 2-1/2 in and Larger                       -                       Carbon Steel, Butt-Welded, 150#
: a. Pump Suction
Valves 2-1/2 in and Smaller                     -                       Carbon Steel, Socket Welded, 600#
 
Code                        ASA B31.1-1955        ASA B31.1-1955 ASA B16.5-1961        ASA B16.5-1961
Underground Aboveground
 
Material 304 Stainless Steel Carbon Steel
 
Construction Welded Except at Flanged Equipment Connections
 
Valves 2-1/2 in and Larger - Carbon Steel, Butt-Welded, 150#
Valves 2-1/2 in and Smaller - Carbon Steel, Socket Welded, 600#


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                               TABLE 9-12 Revision 36 Page 3 of 4 AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
Code ASA B31.1-1955 ASA B31.1-1955 ASA B16.5-1961 ASA B16.5-1961
: b. Pump Discharge Underground             Aboveground Material                   304 Stainless Steel     Carbon Steel Upstream Downstream of FW       of FW Control       Control Valve       Valve Construction                   Welded Except at Flanged Equipment Only Valves 2-1/2 in and Larger                     -                       Carbon Steel, Butt-Welded, 600#
 
Valves 2-1/2 in and Smaller                     -                       Carbon Steel, Socket Welded, 600#
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 3 of 4
Code                       ASA B31.1-1955         ASA B31.1-1955 ASA B16.5-1961         ASA B16.5-1961
 
: c. Auxiliary Turbine Steam Supply Piping and Valves Same as for Aboveground Pump Discharge Piping
AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
: b. Pump Discharge
 
Underground Aboveground
 
Material 304 Stainless Steel Carbon Steel
 
Upstream Downstream of FW of FW Control Control Valve Valve
 
Construction Welded Except at Flanged Equipment Only
 
Valves 2-1/2 in and Larger - Carbon Steel, Butt-Welded, 600#
 
Valves 2-1/2 in and Smaller - Carbon Steel, Socket Welded, 600#
 
Code ASA B31.1-1955 ASA B31.1-1955 ASA B16.5-1961 ASA B16.5-1961
: c. Auxiliary Turbine Steam Supply
 
Piping and Valves Same as for Aboveground Pump Discharge Piping
: 5. Diesel-Driven Auxiliary Feedwater Pump (P-8D)
: 5. Diesel-Driven Auxiliary Feedwater Pump (P-8D)
Type                            Horizontal Centrifugal, with Mechanical Seals Number                          1 Diesel Engine (K-17)            800 hp, Starter with Storage Batteries Codes                          NFPA 20, NFPA 37, UL 1247


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                             TABLE 9-12 Revision 36 Page 4 of 4 AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
Type Horizontal Centrifugal, with Mechanical Seals
 
Number 1
 
Diesel Engine (K-17) 800 hp, Starter with Storage Batteries
 
Codes NFPA 20, NFPA 37, UL 1247
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 4 of 4
 
AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS
: 6. Piping and Valves for P-8D
: 6. Piping and Valves for P-8D
: a. Pump Section Underground          Aboveground Material                    304 Stainless Steel  Carbon Steel Construction                Welded Except at Flanged Equipment Connections Valves 2-1/2 in and Larger                        Carbon Steel, Butt-Welded, 150#
: a. Pump Section
Valves 2-1/2 in and Smaller                      Carbon Steel, Butt-Welded, 600#
Code                        ASA B31.1 1-2012 for procurement ASA B31.1 1-1973 for qualification
: b. Pump Discharge Underground          Aboveground Material                    304 Stainless Steel  Carbon Steel Construction                Welded, Except Flanged at Material Transition Valves 2-1/2 in and Larger                        Carbon Steel, Butt-Welded, 900#
Valves 2-1/2 in and Smaller                      Carbon Steel, Butt-Welded,1500#
Code                        B31.1 (1973)          B31.1 (1973)


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                                                                       TABLE 9-13 Revision 36 Page 1 of 1 DESIGN BASIS AMBIENT CONDITIONS HVAC Original Design Winter, &deg;F                      Summer, &deg;F Location                                                Outside        Inside          Outside      Inside Turbine Building Operating Floor (EEQ Harsh Area)                           -10             50            95            104 Piping Area (EEQ Harsh Area)                               -10              50            95            110 Shops and Offices                                          -10              65            95            104 Auxiliary Building (Non-EEQ Harsh Areas)
Underground Aboveground
Radwaste Area and Radwaste Area Addition                  -10              50            95            110 Fuel Handling Area and Fuel Handling Area
 
                                                                                -10              50            95             104 Addition Office Area                                                -10              75            95              75 Auxiliary Building (EEQ Harsh Areas)
Material 304 Stainless Steel Carbon Steel
Room 123 (590 Component Cooling) (Note 1)                 -10            50              95            104 Room 238 (607-6 Containment Purge Exhaust) (Note 1)      -10              50            95            104 Room 338 (625 Containment Purge Air Fan) (Note 1)         -10              50            95            104 Containment Building (EEQ Harsh Area)                        -10              50            95            104 Control Room (Non-EEQ Harsh Area) (Note 2)                  -10              75            95              75 Condensate and Makeup Demineralizer Building -
 
Non-EEQ Harsh Areas Process and Equipment Area                                -10              50            90            104 Covered Receiving and Loading Area                        -10              50            90            104 Boiler Room                                                -10              50            90            104 Pipe Gallery                                              -10              50            90            104 Instrument Room                                            -10              75            90              90 Note 1: Rooms 123, 238 and 338 have a design temperature of 120&deg;F per M-391, Specification for Installation of Ventilation Equipment and Ductwork Penetration and Fans Rooms.
Construction Welded Except at Flanged Equipment Connections
Note 2: The relative humidity in the control room is 50%
 
Valves 2-1/2 in and Larger Carbon Steel, Butt-Welded, 150#
 
Valves 2-1/2 in and Smaller Carbon Steel, Butt-Welded, 600#
 
Code ASA B31.1 1-2012 for procurement ASA B31.1 1-1973 for qualification
: b. Pump Discharge
 
Underground Aboveground
 
Material 304 Stainless Steel Carbon Steel
 
Construction Welded, Except Flanged at Material Transition
 
Valves 2-1/2 in and Larger Carbon Steel, Butt-Welded, 900#
 
Valves 2-1/2 in and Smaller Carbon Steel, Butt-Welded,1500#
 
Code B31.1 (1973) B31.1 (1973)
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-14 Revision 36 Page 1 of 3
 
CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA
 
Makeup/Recirculation Air Filter Units
 
Quantity Two - 100% Capacity Each
 
Capacity 3,200 ft3/min
 
Filters (per Filtering Unit)
 
Prefilter Quantity 3 Media Glass Fiber or Knitted Pad
 
HEPA Filter Quantity 3 Upstream Filters 3 Downstream Filters Media Glass Fiber
 
Charcoal Filter Trays Quantity 18 [2 Banks of 9]
Media Activated Carbon, 4 in. Bed Depth (Two-2 inch deep Trays in Series)
 
Fan Type Vaneaxial
 
Fan Static Pressure at Rating, in wg 10 in
 
Motor 20 hp, 460 V, 3 Ph
 
Filter Test Efficiency HEPA 99.97% of Particulate Carbon Adsorber 99.9% of Elemental Iodine Electric Heating Coil Type Nickel/Chromium Capacity 15 kW, 480 V, 3 Ph
 
Air Filter Unit Assembly
' P of wg 8.00 in (Maximum)
 
NOTE: All electrical equipment is Class 1E unless otherwise noted.
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-14 Revision 36 Page 2 of 3
 
CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA
 
Air Handling Unit V-95 or V-96
 
Type Package (Filter, Cooling Coil, Fan)
 
Capacity 12,500 ft3/min
 
Cooling Coil Type Direct Expansion Refrigerant Capacity (Total) 603,500 Btu/h
 
Heating Coil (Nonclass 1E)
Type 80% Nickel and 20% Chromium Capacity 177 kW, 480 V, 3 Ph
 
Fan Type Centrifugal Total Pressure, wg 3.85 in Motor 25 hp, 460 V, 3 Ph
 
Filter Type, Media 6 in Thick Moderate Efficiency Prefilter P of wg (Clean) 0.25 in
 
Refrigerant Condensing Unit
 
Type Water-Cooled Reciprocating
 
Refrigerant R-22
 
Compressor Type Reciprocating, 4 Cylinder Motor 60 hp, 460 V, 3 Ph
 
Capacity 554,400 Btu/h @ 85 &deg;F, 39 gpm Service Water
 
Condenser Water Flow Set per RO-216


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                            TABLE 9-14 Revision 36 Page 1 of 3 CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA Makeup/Recirculation Air Filter Units Quantity                              Two - 100% Capacity Each Capacity                              3,200 ft3/min Filters (per Filtering Unit)
Prefilter Quantity                            3 Media                              Glass Fiber or Knitted Pad HEPA Filter Quantity                            3 Upstream Filters 3 Downstream Filters Media                              Glass Fiber Charcoal Filter Trays Quantity                            18 [2 Banks of 9]
Media                              Activated Carbon, 4 in. Bed Depth (Two-2 inch deep Trays in Series)
Fan Type                              Vaneaxial Fan Static Pressure at Rating, in wg                                  10 in Motor                                  20 hp, 460 V, 3 Ph Filter Test Efficiency HEPA                                  99.97% of Particulate Carbon Adsorber                      99.9% of Elemental Iodine Electric Heating Coil Type                                Nickel/Chromium Capacity                            15 kW, 480 V, 3 Ph Air Filter Unit Assembly
    'P of wg                              8.00 in (Maximum)
NOTE: All electrical equipment is Class 1E unless otherwise noted.
NOTE: All electrical equipment is Class 1E unless otherwise noted.
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-14 Revision 36 Page 3 of 3


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                  TABLE 9-14 Revision 36 Page 2 of 3 CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA Air Handling Unit V-95 or V-96 Type                                  Package (Filter, Cooling Coil, Fan)
CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA
Capacity                              12,500 ft3/min Cooling Coil Type                                  Direct Expansion Refrigerant Capacity (Total)                      603,500 Btu/h Heating Coil (Nonclass 1E)
Type                                  80% Nickel and 20% Chromium Capacity                              177 kW, 480 V, 3 Ph Fan Type                                  Centrifugal Total Pressure, wg                    3.85 in Motor                                25 hp, 460 V, 3 Ph Filter Type, Media                    6 in Thick Moderate Efficiency Prefilter P of wg (Clean)                      0.25 in Refrigerant Condensing Unit Type                                  Water-Cooled Reciprocating Refrigerant                            R-22 Compressor Type                                  Reciprocating, 4 Cylinder Motor                                60 hp, 460 V, 3 Ph Capacity                              554,400 Btu/h @ 85 &deg;F, 39 gpm Service Water Condenser Water Flow                  Set per RO-216 NOTE: All electrical equipment is Class 1E unless otherwise noted.


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                      TABLE 9-14 Revision 36 Page 3 of 3 CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA Smoke Purge Exhaust Fan V-94 (Nonclass 1E)
Smoke Purge Exhaust Fan V-94 (Nonclass 1E)
Type                                   Vaneaxial Capacity                               7,800 ft3/min Motor                                 7-1/2 hp, 460 V, 3 Ph Exhaust Fan V-16 (Existing)
 
Type Vaneaxial
 
Capacity 7,800 ft3/min
 
Motor 7-1/2 hp, 460 V, 3 Ph
 
Exhaust Fan V-16 (Existing)
(Nonclass 1E)
(Nonclass 1E)
Type                                   Centrifugal Capacity                               160 ft3 /min Motor                                 1/12 hp, 120 V, 1 Ph Humidifiers VH-12 and VH-13 (Nonclass 1E)
 
Type                                   Steam Generator Capacity                               50 lb/h (17 kW, 480 V, 3 Ph)
Type Centrifugal
 
Capacity 160 ft3 /min
 
Motor 1/12 hp, 120 V, 1 Ph
 
Humidifiers VH-12 and VH-13 (Nonclass 1E)
 
Type Steam Generator
 
Capacity 50 lb/h (17 kW, 480 V, 3 Ph)
 
NOTE: All electrical equipment is Class 1E unless otherwise noted.
NOTE: All electrical equipment is Class 1E unless otherwise noted.


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                         TABLE 9-15 Revision 36 Page 1 of 7 VENTILATION DAMPERS: FUNCTIONS AND POSITIONS FOR VARIOUS MODES OF PLANT OPERATION Position Position After  After Damper      Description        Normal Position    Auto Actuation Loss of Air Control Room D-1       Normal Outside Air - Open - Train A    NA            Close Train A              Close - Train B D-2        Normal Outside Air - Modulate - Train A NA            Close Train A              Close - Train B D-3        Normal Recirc Air -  Open              NA            Open Train A D-4        Supply Air Back      Open - Train A    NA            NA Draft Dampers -      Close - Train B                  (Back Draft)
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-16 Revision 36 Page 1 of 1
Train A D-5        Charcoal Filter Unit Close              NA            NA Supply Air - Train A                                  (Back Draft)
D-6        Charcoal Filter Unit Close              NA            Open Return Air - Train A


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                        TABLE 9-15 Revision 36 Page 2 of 7 VENTILATION DAMPERS: FUNCTIONS AND POSITIONS FOR VARIOUS MODES OF PLANT OPERATION Position Position After  After Damper    Description        Normal Position    Auto Actuation Loss of Air D-7      Charcoal Filter Unit Close              NA            NA Outside Air -                                          (Elect Op FAI)
SAMPLING STATIONS
Train A D-8      Normal Outside Air - Open - Train B    NA            Close Train B              Close - Train A D-9      Normal Outside Air - Modulate - Train B NA            Close Train B              Close - Train A D-10      Normal Recirc Air -  Open              NA            Close Train B D-11      Supply Air Back      Open - Train B    NA            NA Draft Damper -      Close - Train A                  (Back Draft)
Train B D-12      Charcoal Filter Unit Close              NA            NA Supply Air -                                          (Back Draft)
Train B


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                        TABLE 9-15 Revision 36 Page 3 of 7 VENTILATION DAMPERS: FUNCTIONS AND POSITIONS FOR VARIOUS MODES OF PLANT OPERATION Position Position After  After Damper      Description        Normal Position  Auto Actuation Loss of Air D-13      Charcoal Filter Unit Close            NA              Close Return Air -
NSSS Sampling Station
Train B D-14      Charcoal Filter Unit Close            NA              NA Outside Air -                                        (Elect Op FAI)
Train B D-15      Purge Fan Isolation  Close            NA              Close D-16      Purge Fan Isolation  Close            NA              Close D-17      Exhaust Fan V-16    Open            NA              Close Isolation D-18      Exhaust Fan          Open            NA              Close Isolation D-19      Number Not Used      -                -              -
D-20      Charcoal Filter Flow Open            NA              Open Control - Train A


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                          TABLE 9-15 Revision 36 Page 4 of 7 VENTILATION DAMPERS: FUNCTIONS AND POSITIONS FOR VARIOUS MODES OF PLANT OPERATION Position Position After    After Damper      Description          Normal Position    Auto Actuation  Loss of Air D-21        Charcoal Filter Flow  Open                NA              Open Control - Train B Radioactive Waste Area and Engineered Safeguards Rooms PO-3010    Fresh Air Supply      Open                Close on Trip of Close Fan V-10 PO-1809    Radwaste Area Supply Open                Close (RE-1809)  Close PO-1839    Radwaste Area        Open                Close on Trip of Close Exhaust                                  Fan V-14A PO-1840    Radwaste Area        Open                Close on Trip of Close Exhaust                                  Fan V-14B PO-1817    East Safeguards      Open                NA              Close Room Supply PO-1810    East Safeguards      Open                NA              Close Room Exhaust
Containment Hydrogen Monitoring System


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                          TABLE 9-15 Revision 36 Page 5 of 7 VENTILATION DAMPERS: FUNCTIONS AND POSITIONS FOR VARIOUS MODES OF PLANT OPERATION Position Position After    After Damper        Description        Normal Position        Auto Actuation  Loss of Air PO-1812      West Safeguards        Open                  NA              Close Room Supply PO-1811      West Safeguards        Open                  NA              Close Room Exhaust Auxiliary Building Addition Radwaste Area Ventilation System PO-8006      Fresh Air Supply      Open                  Close on Trip of Close Fan V-67 PO-8016A    Radwaste Add          Open                  Close on Trip of Close Exhaust                                      Fan V-68A PO-8016B    Radwaste Add          Open                  Close on Trip of Close Exhaust                                      Fan V-68B
Turbine Analyzer Panel


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                          TABLE 9-15 Revision 36 Page 6 of 7 VENTILATION DAMPERS: FUNCTIONS AND POSITIONS FOR VARIOUS MODES OF PLANT OPERATION Position Position After    After Damper        Description          Normal Position        Auto Actuation  Loss of Air Fuel Handling Area Damper PO-3007 is normally open and fails closed on loss of instrument air.
Radwaste Sampling Station
Auxiliary Building Addition Fuel Handling Area Ventilation System PO-8001      Fresh Air Supply      Open                  Close on Trip of Close Fan V-69 PO-8013A    Fuel Handling Add      Open                  Close on Trip of Close Exhaust                                      Fan V-70A PO-8013B    Fuel Handling Add      Open                  Close on Trip of Close Exhaust                                      Fan V-70B Penetration and Fan Rooms Heating and Ventilation System PO-8035      Outside Air Supply    Open                  Close (RIA-5710) Close PO-8036      Exhaust                Open                  Close (RIA-5710) Close


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                        TABLE 9-15 Revision 36 Page 7 of 7 VENTILATION DAMPERS: FUNCTIONS AND POSITIONS FOR VARIOUS MODES OF PLANT OPERATION Position Position After    After Damper      Description      Normal Position Auto Actuation  Loss of Air Containment CV-1813    Air Space Purge    Open / Close    NA              Close Supply CV-1814    Air Space Purge    Open / Close    NA              Close Supply CV-1806    Cont Purge Exhaust  Open / Close    NA              Close CV-1805    Cont Purge Exhaust  Open / Close    NA              Close CV-1808    Cont Purge Exhaust  Open / Close    NA              Close CV-1807    Cont Purge Exhaust  Open / Close    NA              Close
Waste Gas Sample Panel


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                TABLE 9-16 Revision 36 Page 1 of 1 SAMPLING STATIONS NSSS Sampling Station Containment Hydrogen Monitoring System Turbine Analyzer Panel Radwaste Sampling Station Waste Gas Sample Panel Radwaste Addition Sampling System
Radwaste Addition Sampling System


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                       TABLE 9-17 Revision 36 Page 1 of 1 SAMPLE POINT  
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-17 Revision 36 Page 1 of 1
 
SAMPLE POINT  


==SUMMARY==
==SUMMARY==
: 1. Radwaste Sampling Station Primary System Drain Tank Recirc           Grab Sample Equipment Drain Tank Recirc                 Grab Sample Vacuum Degasifier Pump Discharge           Grab Sample Receiver Tank Pumps Discharge               Grab Sample Receiver Tank Circ Pumps Discharge         Grab Sample Radwaste Demin Tanks Outlet (3)             Grab Sample Treated Waste Mon Tanks Recirc (2)         Grab Sample Controlled Chem Lab Drain Tank             Grab Sample Filtered Waste Monitor Tank Recirc         Grab Sample Dirty Waste Drain Tank Recirc               Grab Sample Component Cooling Pumps Discharge           Grab Sample
: 1. Radwaste Sampling Station
: 2. Waste Gas Sample Panel Volume Control Tank                         Bomb Waste Gas Surge Tank                       Bomb Waste Gas Decay Tanks (6)                   Bomb Spurt Resin Storage Tank                   Bomb
 
: 3. Radwaste Addition Sampling System Radwaste Polishing Demineralizer Discharge Grab Sample, Conductivity Clean Waste Transfer Pump Discharge         Grab Sample Clean Waste Distillate Pump Discharge       Grab Sample Misc Waste Distillate Pumps Discharge (2)   Grab Sample Misc Waste Demineralizer Tank Discharge (2) Grab Sample, Conductivity (1)
Primary System Drain Tank Recirc Grab Sample Equipment Drain Tank Recirc Grab Sample Vacuum Degasifier Pump Discharge Grab Sample Receiver Tank Pumps Discharge Grab Sample Receiver Tank Circ Pumps Discharge Grab Sample Radwaste Demin Tanks Outlet (3) Grab Sample Treated Waste Mon Tanks Recirc (2) Grab Sample Controlled Chem Lab Drain Tank Grab Sample Filtered Waste Monitor Tank Recirc Grab Sample Dirty Waste Drain Tank Recirc Grab Sample Component Cooling Pumps Discharge Grab Sample
Misc Waste Transfer Pumps Discharge (2)     Grab Sample Misc Waste Filter Inlet                     Grab Sample Misc Waste Filter Discharge (2)             Grab Sample Primary System Makeup Water Pump Discharge Grab Sample Utility Water Transfer Pump Discharge       Grab Sample Spurt Resin Storage Tank Gas               Bomb Waste Gas Decay Tanks (3)                   Bomb Radwaste Evaporator Distillate (2)         Grab Sample
: 2. Waste Gas Sample Panel
 
Volume Control Tank Bomb Waste Gas Surge Tank Bomb Waste Gas Decay Tanks (6) Bomb Spurt Resin Storage Tank Bomb
: 3. Radwaste Addition Sampling System
 
Radwaste Polishing Demineralizer Discharge Grab Sample, Conductivity Clean Waste Transfer Pump Discharge Grab Sample Clean Waste Distillate Pump Discharge Grab Sample Misc Waste Distillate Pumps Discharge (2) Grab Sample Misc Waste Demineralizer Tank Discharge (2) Grab Sample, Conductivity (1)
Misc Waste Transfer Pumps Discharge (2) Grab Sample Misc Waste Filter Inlet Grab Sample Misc Waste Filter Discharge (2) Grab Sample Primary System Makeup Water Pump Discharge Grab Sample Utility Water Transfer Pump Discharge Grab Sample Spurt Resin Storage Tank Gas Bomb Waste Gas Decay Tanks (3) Bomb Radwaste Evaporator Distillate (2) Grab Sample
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 1 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.1 Regenerative Heat Exchanger - E-56
 
Quantity 1
 
Type Shell and Tube, Vertical
 
Normal Heat Transfer 6.6 x 106 Btu/h
 
Code ASME B&PV Code, Section III, Class C, 1965
 
Shell Side (Charging)
 
Fluid 15,000 ppm Boric Acid, Maximum (Design)
 
Design Pressure 2,735 psig
 
Design Temperature 650qF
 
Material Stainless Steel
 
Tube Side (Letdown)
 
Fluid 15,000 ppm Boric Acid, Maximum (Design)
 
Design Pressure 2,485 psig
 
Design Temperature 650qF
 
Material Stainless Steel
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 2 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.2 Letdown Orifice - RO-2003, RO-2004 and RO-2005
 
Quantity 3
 
Capacity (Each) 40 gpm
 
Design Pressure 2,485 psia
 
Design Temperature 650qF
 
Material Stainless Steel
 
1.3 Letdown Heat Exchanger - E-58
 
Quantity 1
 
Type Shell and Tube, Horizontal
 
Design Heat Transfer 19.1 x 106 Btu/h
 
Code ASME B&PV Code, Section III, Class C Tube Side (Letdown)
 
Fluid 15,000 ppm Boric Acid, Maximum (Design)
 
Design Pressure 650 psig
 
Design Temperature 550qF
 
Material Stainless Steel
 
Shell Side (Cooling Water)
 
Fluid Component Cooling Water
 
Design Pressure 150 psig
 
Design Temperature 250qF DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 3 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
Material Carbon Steel
 
1.4 Process Radiation Monitor - Element RE-0202
 
Quantity 1
 
Design Pressure 200 psig
 
Design Temperature 250qF
 
Code ASA B31.1
 
1.5 Ion Exchangers - T-51A, T-51B and T-52
 
Quantity 3
 
Type Flushable
 
Design Pressure 200 psig
 
Design Temperature 250qF
 
Resin Volume 32 ft 3
 
Retention Screen 80 US Mesh
 
Code for Vessel ASME B& PV Code, Section III, Class C
 
Material Stainless Steel
 
Fluid 15,000 ppm Boric Acid, Maximum (Design)
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 4 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.6 Purification Filter s - F-54A and F-54B
 
Quantity 2
 
Type of Elements Synthetic Fiber
 
Retention 0.05 to 6.0 Micron Absolute; 1.0 Micron Nominal (or finer)
 
Design Pressure 200 psig
 
Design Temperature 250qF
 
Design Flow 120 gpm
 
Code for Vessel ASME B& PV Code, Section III, Class C, 1965
 
Material Stainless Steel
 
Fluid 15,000 ppm Boric Acid, Maximum (Design)
 
1.7 Volume Control Tank - T-54
 
Quantity 1
 
Type Vertical, Cylindrical
 
Design Pressure, Internal 75 psig
 
Design Pressure, External 15 psig
 
Design Temperature 250qF
 
Internal Volume, Minimum 4,170 gal
 
Code ASME B&PV Code, Section III, Class C, 1965
 
Material Stainless Steel
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 5 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.8 Spray Nozzle (Volume Control Tank)
 
Quantity 1
 
Type Medium Angle, Full Cone
 
Design Pressure 200 psig


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                  TABLE 9-18 Revision 36 Page 1 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.1  Regenerative Heat Exchanger - E-56 Quantity                            1 Type                                Shell and Tube, Vertical Normal Heat Transfer                6.6 x 106 Btu/h Code                                ASME B&PV Code, Section III, Class C, 1965 Shell Side (Charging)
Design Temperature 250qF
Fluid                              15,000 ppm Boric Acid, Maximum (Design)
Design Pressure                    2,735 psig Design Temperature                650qF Material                          Stainless Steel Tube Side (Letdown)
Fluid                              15,000 ppm Boric Acid, Maximum (Design)
Design Pressure                    2,485 psig Design Temperature                 650qF Material                          Stainless Steel


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                        TABLE 9-18 Revision 36 Page 2 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.2  Letdown Orifice - RO-2003, RO-2004 and RO-2005 Quantity                                  3 Capacity (Each)                          40 gpm Design Pressure                          2,485 psia Design Temperature                        650qF Material                                  Stainless Steel 1.3  Letdown Heat Exchanger - E-58 Quantity                                  1 Type                                      Shell and Tube, Horizontal Design Heat Transfer                      19.1 x 106 Btu/h Code                                      ASME B&PV Code, Section III, Class C Tube Side (Letdown)
Maximum Spray Flow 120 gpm
Fluid                                    15,000 ppm Boric Acid, Maximum (Design)
Design Pressure                          650 psig Design Temperature                        550qF Material                                  Stainless Steel Shell Side (Cooling Water)
Fluid                                    Component Cooling Water Design Pressure                          150 psig Design Temperature                        250qF


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                      TABLE 9-18 Revision 36 Page 3 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS Material                                 Carbon Steel 1.4  Process Radiation Monitor - Element RE-0202 Quantity                                1 Design Pressure                          200 psig Design Temperature                      250qF Code                                    ASA B31.1 1.5  Ion Exchangers - T-51A, T-51B and T-52 Quantity                                3 Type                                    Flushable Design Pressure                          200 psig Design Temperature                      250qF Resin Volume                            32 ft3 Retention Screen                        80 US Mesh Code for Vessel                          ASME B&PV Code, Section III, Class C Material                                Stainless Steel Fluid                                    15,000 ppm Boric Acid, Maximum (Design)
Material Stainless Steel


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                        TABLE 9-18 Revision 36 Page 4 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.6  Purification Filters - F-54A and F-54B Quantity                                2 Type of Elements                        Synthetic Fiber Retention                                0.05 to 6.0 Micron Absolute; 1.0 Micron Nominal (or finer)
1.9 Variable Speed Char ging Pump - P-55A
Design Pressure                          200 psig Design Temperature                      250qF Design Flow                              120 gpm Code for Vessel                          ASME B&PV Code, Section III, Class C, 1965 Material                                Stainless Steel Fluid                                    15,000 ppm Boric Acid, Maximum (Design) 1.7  Volume Control Tank - T-54 Quantity                                1 Type                                    Vertical, Cylindrical Design Pressure, Internal                75 psig Design Pressure, External                15 psig Design Temperature                      250qF Internal Volume, Minimum                4,170 gal Code                                    ASME B&PV Code, Section III, Class C, 1965 Material                                Stainless Steel


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                    TABLE 9-18 Revision 36 Page 5 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.8  Spray Nozzle (Volume Control Tank)
Quantity 1
Quantity                            1 Type                                Medium Angle, Full Cone Design Pressure                      200 psig Design Temperature                  250qF Maximum Spray Flow                  120 gpm Material                            Stainless Steel 1.9  Variable Speed Charging Pump - P-55A Quantity                             1 Type                                Positive Displacement Design Pressure                      2,735 psig Design Temperature                  250qF Maximum Discharge Pressure (Short Term)                        2,900 psig NPSH Required                        7.65 ft (Ref. 25)
Maximum Pressure Pump Starts Against                              2,485 psig Driver Rating                        100 hp Type Variable Capacity Device        Fluid Drive Materials in Contact With Pumped    Stainless Steel or Equivalent Fluid                                Corrosion Resistance Fluid                                12 Wt% Boric Acid, Maximum (Design)


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                   TABLE 9-18 Revision 36 Page 6 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.10 Constant Speed Charging Pumps - P-55B and P-55C Quantity                               2 Type                                   Positive Displacement Design Pressure                       2,735 psig Design Temperature                     250qF Flow Rate                             40 gpm Maximum Discharge Pressure (Short Term)                           3,010 psig NPSH Required                         7.41 ft (Ref. 25)
Type Positive Displacement
NPSH Available P-55B/C                 28.22/28.18 ft (Ref. 25)
 
Design Pressure 2,735 psig
 
Design Temperature 250qF
 
Maximum Discharge Pressure (Short Term) 2,900 psig
 
NPSH Required 7.65 ft (Ref. 25)
 
Maximum Pressure Pump Starts Against 2,485 psig
 
Driver Rating 100 hp
 
Type Variable Capacity Device Fluid Drive
 
Materials in Contact With Pum ped Stainless Steel or Equivalent Fluid Corrosion Resistance
 
Fluid 12 Wt% Boric Acid, Maximum (Design)
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 6 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.10 Constant Speed Charging Pumps - P-55B and P-55C
 
Quantity 2
 
Type Positive Displacement
 
Design Pressure 2,735 psig
 
Design Temperature 250qF
 
Flow Rate 40 gpm
 
Maximum Discharge Pressure (Short Term) 3,010 psig
 
NPSH Required 7.41 ft (Ref. 25)
 
NPSH Available P-55B/C 28.22/28.18 ft (Ref. 25)
(Normal Suction From VCT)
(Normal Suction From VCT)
Maximum Pressure Pump Starts Against                                2,500psig Driver Rating                          75 hp Pump Cooling Water Requirements        5 gpm, 15qF Rise Fluid                                  12 Wt% Boric Acid, Maximum (Design)


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                   TABLE 9-18 Revision 36 Page 7 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.11 Boric Acid Batching Tank - T-77 Quantity                               1 Internal Volume                       580 gal Design Pressure                       Atmospheric Design Temperature                     200qF Type Heater                           Electric Immersion Heater Capacity                       31.5 kw Minimum Code                                   ASME B&PV Code, Section VIII Fluid                                 12 Wt % Boric Acid, Maximum (Design)
Maximum Pressure Pump Starts Against 2,500psig
Material                               Stainless Steel 1.12 Boric Acid Strainer - F-10 (YS-0224)
 
Quantity                               1 Type                                   Basket Design Pressure                       125 psig Design Temperature                     250qF Screen Size                           100 x 100 US Mesh Design Flow                           50 gpm Material                               Stainless Steel Fluid                                 12 Wt % Boric Acid, Maximum (Design)
Driver Rating 75 hp
 
Pump Cooling Water Requirements 5 gpm, 15 qF Rise
 
Fluid 12 Wt% Boric Acid, Maximum (Design)
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 7 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.11 Boric Acid Batching Tank - T-77
 
Quantity 1
 
Internal Volume 580 gal
 
Design Pressure Atmospheric
 
Design Temperature 200qF
 
Type Heater Electric Immersion
 
Heater Capacity 31.5 kw Minimum
 
Code ASME B&PV Code, Section VIII
 
Fluid 12 Wt % Boric Acid, Maximum (Design)
 
Material Stainless Steel
 
1.12 Boric Acid Strainer - F-10 (YS-0224)
 
Quantity 1
 
Type Basket
 
Design Pressure 125 psig
 
Design Temperature 250qF
 
Screen Size 100 x 100 US Mesh
 
Design Flow 50 gpm
 
Material Stainless Steel
 
Fluid 12 Wt % Boric Acid, Maximum (Design)
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 8 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.13 Concentrated Boric Acid Storage Tanks - T-53A and T-53B
 
Quantity 2
 
Internal Volume 6,550 gal
 
Design Pressure Atmospheric
 
Design Temperature 200qF
 
Type Heater Electrical, Dry Well Installation
 
Heater Capacity Two Independent 4 kW Banks per Tank
 
Fluid 12 Wt % Boric Acid, Maximum (Design)
 
Material Stainless Steel
 
Code ASME B&PV Code, Section III, Class C, 1965
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 9 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
1.14 Boric Acid Pumps - P-56A and P-56B
 
Quantity 2
 
Type Centrifugal
 
Design Pressure 150 psig
 
Design Temperature 250qF
 
Design Head 225 ft
 
Design Flow 143 gpm
 
NPSH Required 7.50 ft (Ref. 25)
 
NPSH Available P-56A/B 25.06/25.23 (Ref. 25)
 
Horsepower 30
 
Fluid 12 Wt % Boric Acid, Maximum (Design)
 
Material in Cont act With Liquid Stainless Steel
 
1.15 Boric Acid Filter - F-9
 
Quantity 1
 
Type Elements Synthetic Fiber
 
Retention of 5 Micron Particles 98%
 
Design Pressure 150 psig
 
Design Temperature 250qF DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 10 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
Design Flow 140 gpm
 
Material Stainless Steel
 
Liquid 12 Wt % Bo ric Acid, Maximum (Design)
 
Code ASME B&PV Code, Section III, Class C, 1965
 
1.16 Chemical Addition Tank - T-56
 
Quantity 1
 
Capacity 10.5 gal
 
Design Pressure Atmospheric
 
Design Temperature 200qF
 
Material Stainless Steel
 
Fluid Hydrazine (N2H4), LiOH, KOH, NH4OH
 
Code ASME B&PV Code, Section VIII
 
1.17 Chemical Addition Strainer - F-58
 
Quantity 1
 
Type Basket
 
Design Pressure 100 psig
 
Design Temperature 250qF
 
Screen Size 60 US Mesh DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 11 of 11
 
CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS
 
Design Flow 30 gph
 
Material Stainless Steel
 
Fluid Hydrazine (N2H4), LiOH, KOH, NH4OH
 
1.18 Metering Pump - P-57
 
Quantity 1
 
Type Air Operated Double Diaphragm
 
Design Pressure 120 psig
 
Design Temperature 190qF
 
Design Flow Rate 0 to 35 gpm
 
Design Air Consum ption 0 to 50 scfm
 
Material Stainless Steel
 
Fluid Hydrazine (N2H4), LiOH, KOH, NH4OH DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-19 Revision 36 Page 1 of 1
 
FUEL HANDLING DATA
: 1. New Fuel Storage Rack
 
Core Storage Capacity 1/6
 
Equivalent Fuel Assemblies 36
 
Center-to-Center Spacing of Assemblies 11 in
: 2. Spent Fuel Storage Pool
 
Core Storage Capacity 4.3
 
Equivalent Fuel Assemblies 892
 
Number of Space Accommodations for Spent Fuel Shipping Casks 1
 
Center-to-Center Spacing of Assemblies Region 1 10-1/4 in Region 2 9.17 in
 
Maximum keff With Unborated Water Less Than 1.0
: 3. Miscellaneous Details
 
Wall Thickness for Spent Fuel Storage Pool 4 ft to 6-1/2 ft
 
Weight of Fuel Assembly 1,500 lb
 
Capacity of Refueling Water Storage Tank 285,000 gal
 
Quantity of Water Required for Fuel Handling 250,000 gal
 
DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-20 Revision 36 Page 1 of 2
 
FUEL BUILDING CRANE
 
Main Hoist 3 ft/min at Full Load (3 Steps), 25 hp at 900 r/min
 
Main Hoist Brake Capacity 179 ft-lb
 
Auxiliary Hoist 25 ft/min at Full Load (Stepless), 25 hp at 900 r/min
 
Trolley 25 ft/min at Full Load (3 Steps), 3 hp at 1,800 r/min
* Bridge 25 ft/min at Full Load (3 Steps), 5 hp at 1,800 r/min
* Service Class Class A, Electric Overhead Crane Institute Specification 70
 
Lift Main Hoist 54 ft 0 in
 
Lift Auxiliary Hoist 108 ft 5 in
 
Span 44 ft 10 in Center-to-Center Rails
 
Bridge Travel Approximately 100 ft
 
Lifting Tackle Main Hoist - Rope 16 Parts 13/4-Inch SS, Drum 521/2-Inch Pitch Diameter, Sheaves 28-Inch Pitch Diameter
 
Auxiliary Hoist - Rope 4 Parts 3/4-Inch SS, Drum 15-Inch Pitch Diameter, Sheaves 13-Inch Pitch Diameter
 
Girders Welded Box Section
 
Runway Rail 100 lbs ASCE
 
Trolley Rail 175 lbs USS
 
Bridge Drive Direct Drive Arrangement With Oiltight Center Gear Case
 
Trolley Drive Direct Drive Arrangement With Oiltight Center Gear Case
* Single failure proof mode of operation only DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-20 Revision 36 Page 2 of 2
 
FUEL BUILDING CRANE


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                    TABLE 9-18 Revision 36 Page 8 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.13 Concentrated Boric Acid Storage Tanks - T-53A and T-53B Quantity                            2 Internal Volume                    6,550 gal Design Pressure                    Atmospheric Design Temperature                  200qF Type Heater                        Electrical, Dry Well Installation Heater Capacity                     Two Independent 4 kW Banks per Tank Fluid                              12 Wt % Boric Acid, Maximum (Design)
Capacity in Net Tons Bridge 110 Tons, Main Hoist 110 Tons, Auxiliary Hoist 15 Tons
Material                            Stainless Steel Code                                ASME B&PV Code, Section III, Class C, 1965


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                    TABLE 9-18 Revision 36 Page 9 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS 1.14 Boric Acid Pumps - P-56A and P-56B Quantity                              2 Type                                  Centrifugal Design Pressure                        150 psig Design Temperature                    250qF Design Head                            225 ft Design Flow                            143 gpm NPSH Required                          7.50 ft (Ref. 25)
Wheels Bridge Has Eight 21-Inch Steel Hardened Treads
NPSH Available P-56A/B                  25.06/25.23 (Ref. 25)
Horsepower                            30 Fluid                                  12 Wt % Boric Acid, Maximum (Design)
Material in Contact With Liquid        Stainless Steel 1.15 Boric Acid Filter - F-9 Quantity                              1 Type Elements                          Synthetic Fiber Retention of 5 Micron Particles        98%
Design Pressure                        150 psig Design Temperature                    250qF


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                  TABLE 9-18 Revision 36 Page 10 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS Design Flow                          140 gpm Material                            Stainless Steel Liquid                              12 Wt % Boric Acid, Maximum (Design)
Trolley Has Four 21-Inch Diameter Steel Hardened Treads
Code                                ASME B&PV Code, Section III, Class C, 1965 1.16 Chemical Addition Tank - T-56 Quantity                            1 Capacity                            10.5 gal Design Pressure                      Atmospheric Design Temperature                  200qF Material                            Stainless Steel Fluid                                Hydrazine (N2H4), LiOH, KOH, NH4OH Code                                ASME B&PV Code, Section VIII 1.17 Chemical Addition Strainer - F-58 Quantity                            1 Type                                Basket Design Pressure                      100 psig Design Temperature                  250qF Screen Size                          60 US Mesh


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                TABLE 9-18 Revision 36 Page 11 of 11 CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS Design Flow                        30 gph Material                            Stainless Steel Fluid                              Hydrazine (N2H4), LiOH, KOH, NH4OH 1.18 Metering Pump - P-57 Quantity                            1 Type                                Air Operated Double Diaphragm Design Pressure                    120 psig Design Temperature                  190qF Design Flow Rate                    0 to 35 gpm Design Air Consumption              0 to 50 scfm Material                            Stainless Steel Fluid                              Hydrazine (N2H4), LiOH, KOH, NH4OH
Bridge End Assembly Rotating Axle


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                    TABLE 9-19 Revision 36 Page 1 of 1 FUEL HANDLING DATA
Bumpers Rubber
: 1. New Fuel Storage Rack Core Storage Capacity                        1/6 Equivalent Fuel Assemblies                    36 Center-to-Center Spacing of Assemblies        11 in
: 2. Spent Fuel Storage Pool Core Storage Capacity                        4.3 Equivalent Fuel Assemblies                    892 Number of Space Accommodations for Spent Fuel Shipping Casks                                1 Center-to-Center Spacing of Assemblies Region 1                                    10-1/4 in Region 2                                    9.17 in Maximum keff With Unborated Water            Less Than 1.0
: 3. Miscellaneous Details Wall Thickness for Spent Fuel Storage Pool    4 ft to 6-1/2 ft Weight of Fuel Assembly                      1,500 lb Capacity of Refueling Water Storage Tank      285,000 gal Quantity of Water Required for Fuel Handling  250,000 gal


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                                        TABLE 9-20 Revision 36 Page 1 of 2 FUEL BUILDING CRANE Main Hoist                    3 ft/min at Full Load (3 Steps), 25 hp at 900 r/min Main Hoist Brake Capacity    179 ft-lb Auxiliary Hoist              25 ft/min at Full Load (Stepless), 25 hp at 900 r/min Trolley                      25 ft/min at Full Load (3 Steps), 3 hp at 1,800 r/min
Bearings Antifriction Throughout
* Bridge                        25 ft/min at Full Load (3 Steps), 5 hp at 1,800 r/min
* Service Class                Class A, Electric Overhead Crane Institute Specification 70 Lift Main Hoist              54 ft 0 in Lift Auxiliary Hoist          108 ft 5 in Span                          44 ft 10 in Center-to-Center Rails Bridge Travel                Approximately 100 ft Lifting Tackle                Main Hoist - Rope 16 Parts 13/4-Inch SS, Drum 521/2-Inch Pitch Diameter, Sheaves 28-Inch Pitch Diameter Auxiliary Hoist - Rope 4 Parts 3/4-Inch SS, Drum 15-Inch Pitch Diameter, Sheaves 13-Inch Pitch Diameter Girders                      Welded Box Section Runway Rail                  100 lbs ASCE Trolley Rail                  175 lbs USS Bridge Drive                  Direct Drive Arrangement With Oiltight Center Gear Case Trolley Drive                Direct Drive Arrangement With Oiltight Center Gear Case
* Single failure proof mode of operation only


DSAR CHAPTER 9 - AUXILIARY SYSTEMS                                            TABLE 9-20 Revision 36 Page 2 of 2 FUEL BUILDING CRANE Capacity in Net Tons  Bridge 110 Tons, Main Hoist 110 Tons, Auxiliary Hoist 15 Tons Wheels                Bridge Has Eight 21-Inch Steel Hardened Treads Trolley Has Four 21-Inch Diameter Steel Hardened Treads Bridge End Assembly    Rotating Axle Bumpers                Rubber Bearings              Antifriction Throughout Gearing               Helical Gearing Heat-Treated Steel Throughout Except Trolley Traverse. All Gearing in Oiltight Casing}}
Gearing Helical Gearing Heat-Treated Steel Throughout Except Trolley Traverse. All Gearing in Oiltight Casing}}

Revision as of 19:46, 14 November 2024

6 to Updated Final Safety Analysis Report, Chapter 9, Tables
ML23107A042
Person / Time
Site: Palisades Entergy icon.png
Issue date: 03/31/2023
From:
Holtec Decommissioning International
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23107A065 List: ... further results
References
HDI PNP 2023-002
Download: ML23107A042 (58)


Text

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-1 Revision 36 Page 1 of 1

HISTORIC SERVICE WATER SYSTEM FLOW REQUIREMENTS (gpm)

Component Name

Critical Service Water Header

CCW Heat Exchangers <6000

Control Room Air Conditioning 12(1)

Instrument Air Compressors (C-2A, C-2C) 16 Alternate to Replenish SFP(3) 40

Noncritical Service Water Header(2)

Instrument Air Compressor C-2B Aftercooler 8

Circ Water and Intake Basin Chlorinator 50

Aux Building Addition Air Conditioning Unit 28.8 Ventilation Equipment Room Air Cooling Unit 28.8 Radwaste Area Compressor 20 Auxiliary Building Condensing Unit 130 FWP Air Compressor 65.2

CD Bldg Boiler Sample (measured) Cooler 1.6 Plant Htg Condensate Return Heat Exchanger (E-924) 100(4)

Radiation Monitors 10

NOTES:

(1)- Only one unit (or set of coolers) is operated at one time.

(2)- Flows listed here are from original Bechtel figures and have not been verified.

(3)- Provisions exist to allow the Service Water System to replenish the Spent Fuel Pool (SFP)

(4)- Flow is temperature controlled.

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-2 Revision 36 Page 1 of 2

SERVICE WATER SYSTEM CONSTRUCTION OF COMPONENTS

1. Service Water Pumps

Type Vertical Turbine With Water Lubrication

Number 3

Material

Bowls Cast Iron or Cast Steel or Cast Stainless Steel

Discharge Head Carbon Steel

Bowl Shaft 416 SS

Line Shaft 1045 CS or 416 SS

Discharge Column Carbon Steel

Impeller Bronze or Stainless Steel

Motor 350 hp, 3 Ph, 60 Hz, 2,300 V

Codes Standards of Hydraulic Institute, NEMA, ASA and ASTM

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-2 Revision 36 Page 2 of 2

SERVICE WATER SYSTEM CONSTRUCTION OF COMPONENTS

2. Basket Strainers

Type Simplex Multi-Basket

Number 3

Screen Mesh 3/16 in Perforation

Material

Body Cast Steel

Baskets 304 SS

3. Piping, Fittings and Valves

Material Carbon Steel, Bronze, Stainless Steel, or Cast Iron & Ductile Iron (non-safety related only)

Piping and Fittings(a) 2-1/2 in and Larger - Butt-Welded Except at Flanged Equipment(a)

2 in and Smaller - Socket Welded Except at Flanged Equipment or Threaded

Valves(a) 2-1/2 in and Larger - Butt-Welded 150 lb(a)

2 in and Smaller - Socket Welded 600 lb or Threaded 200 lb or Flanged 150 lb Class

Code ASA B31.1-1955 ASA B16.5-1961

(a) These are considered to be classified as flanged equipment.

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-3 Revision 36 Page 1 of 3

REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS

1. Shield Cooling Coils

Length (Each Coil) Approx 24 ft

Spacing of Coils 9 in Center-to-Center

Number of Coil Sections in Each Set 3

Coil Diameter 3/4 in

Material Seamless Carbon Steel

Code ASA B31.1

2. Shield Cooling Pumps

Type Horizontal Centrifugal With Mechanical Seals

Number 2

Material

Case Cast Iron

Impeller CD4MCU (Stainless Steel)

Shaft Stainless Steel (Solid)

Motor 7.5 hp, 3 Ph, 60 Hz, 460 V, 1750 r/min

Codes Standards of Hydraulic Institute, NEMA, ASA and ASTM

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-3 Revision 36 Page 2 of 3

REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS

3. Shield Cooling Heat Exchanger

Type Horizontal Counterflow, Shell With Straight Tubes Rolled Into Fixed Tube Sheets

Number 1

Material

Shell Carbon Steel

Tubes Admiralty

Channels Carbon Steel

Tube Sheets Aluminum Bronze

Codes ASME B&PV Code,Section III, Class C and ASME B&PV Code,Section VIII, Par UW-2 (a);

TEMA Class C

4. Shield Cooling Surge Tank

Type Vertical

Number 1

Material Carbon Steel

Code ASME B&PV Code Section III, Class C and ASME B&PV Code,Section VIII, Par UW-2 (a)

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-3 Revision 36 Page 3 of 3

REACTOR PRIMARY SHIELD COOLING SYSTEM CONSTRUCTION OF COMPONENTS

5. Piping, Fittings and Valves

Material Seamless Carbon Steel

Not Embedded in Embedded In Concrete Concrete Construction

Pipe, 2-1/2 in and Larger Butt-Welded Except None at Flanged Equipment

Pipe, 2 in and Smaller Screwed Except at Socket Flanged Equipment Welded

Valves, 2-1/2 in and Larger Cast Iron, None Flanged 125#

Valves, 2 in and Smaller Bronze, Screwed None 200# and Carbon Steel, flanged 150#

Code ASA B31.1

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-4 Revision 36 Page 1 of 1

COMPONENT COOLING SYSTEM HEAT LOADS (x 106 Btu/hr)

Component and (Number)

Spent Fuel Pool HX (1) 9.2

Waste Gas Compressors (3) 0.01

Total 9.21 DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-5 Revision 36 Page 1 of 2

COMPONENT COOLING WATER SYSTEM CONSTRUCTION OF COMPONENTS

1. Component Cooling Pumps

Type Horizontal Centrifugal With Mechanical Seals

Number 3

Material

Case Carbon Steel

Impeller Bronze

Shaft Alloy Steel

Motor 300 hp, 3 Ph, 60 Hz, 2,300 V

Codes Standards of Hydraulic Institute, NEMA, ASA and ASTM

2. Component Cooling Heat Exchangers

Type Horizontal, Counterflow, Shell Straight Tubes, Tubes Rolled Into Tube Sheets

Number 2

Original Heat Transfer Area (Each) 7,840 ft2

Material

Shell Side Carbon Steel, Firebox Quality

Tube Side Admiralty

Tube Sheet Carbon Steel With Aluminum Bronze Overlay

Codes ASME B&PV Code,Section III, Class C, 1965 and ASME B&PV Code,Section VIII, Par UW-2 (a); TEMA Class C DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-5 Revision 36 Page 2 of 2

COMPONENT COOLING WATER SYSTEM CONSTRUCTION OF COMPONENTS

3. Surge Tank

Type Vertical

Number 1

Material Carbon Steel

Code ASME B&PV Code,Section III, Class C, 1965

4. Piping, Fittings and Valves

Piping Material Carbon Steel, Seamless and Seam Welded (Seam Weld 100% Radiographed)

Inside Outside Containment Containment

Construction

Pipe, 2-1/2 in and Larger Butt-Welded Except Butt-Welded at Flanged Equipment, Except at 10% of Circumferen-Flanged tial Welds Examined Equipment by Radiography

Pipe, 2 in and Smaller Socket Welded Screwed Except-Except Flanged at Flanged Equipment Equipment

Valves (Except Butterfly), Carbon Steel, Cast Iron, 2-1/2 in and Larger Butt Weld Flanged Ends, 150# Ends, 125#

Butterfly Valves, Carbon Steel, Carbon Steel, 2-1/2 in and Larger Flanged Ends, 150# Flanged Ends, 150#

Valves, 2 in and Smaller Carbon Steel, Socket Bronze, Welded Ends, Screwed 600# Ends, 200#

Code ASA B31.1-1955 ASA B31.1-1955 ASA B16.5-1961 ASA B16.5-1961

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-6 Revision 36 Page 1 of 1

COMPONENT COOLING SYSTEM REQUIRED FLOW RATES (GPM)

Component and (Number) Normal

Spent Fuel Pool HX (1) *** 650

Waste Gas Compressors (3) 6

Vacuum Degasifier Pump Seal 8 Water Cooler (1)

Total 664

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 1 of 4

SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

1. Fuel Pool Cooling Pumps

Type Horizontal Centrifugal With Mechanical Seals

Number 2

Capacity (Each) 1,700 gpm

TDH 64 ft

Temperature Transient Designed To Withstand an Increase from 60qF to 212qF in 5 Seconds

Material Stainless Steel

Motor 40 hp, 460 V, 60 Hz 3 Ph,

Code Motor, NEMA; Pump, Standards of Hydraulic Institute

2. Spent Fuel Pool Cooling Heat Exchange Unit

Type Horizontal Counterflow, With Straight Tubes Rolled Into Tube Sheets

Number 2 Shells in Series

Original Duty (Total) 23 x 106 Btu/h

Original Heat Transfer Area 4,080 ft2

Component Cooling Water Temperature: In/Out 90/115qF

Spent Fuel Cooling Water Temperature: In/Out 125/110qF

Temperature Transient Designed To Withstand an Increase From 60qF to 212qF in 5 Seconds DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 2 of 4

SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

Material

Shells Carbon Steel

Tubes Stainless Steel

Tube Sheets Stainless Steel With SS 308L Weld Overlay

Codes ASME B&PV Code,Section III, Class C and ASME B&PV Code,Section VIII, Par UW2 (a);

TEMA Class C

3. Fuel Pool Recirculation Booster Pump

Type Horizontal Centrifugal With Mechanical Seals

Number 1

Capacity 160 gpm

TDH 160 ft

Temperature Transient Designed To Withstand Increase From 60qF to 212qF in 5 Seconds

Material Type 316 Stainless Steel

Motor 15 hp, 3 Ph, 60 Hz 460 V

Code Motor, NEMA; Pump, Standards of Hydraulic Institute

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 3 of 4

SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

4. Fuel Pool Filter

Type Cartridge With Replaceable Filter Element

Number 1

Design Flow 150 gpm

Design Pressure 200 psig

Design Temperature 250qF

Temperature Transient Designed for Increase From 60qF to 212qF in 5 Seconds

Filter Rating 25 Microns Nominal

Material Stainless Steel

Codes ASME B&PV Code,Section III, Class C and ASME B&PV Code,Section VIII, Par UW2 (a)

5. Fuel Pool Demineralizer

Type Mixed Bed

Number 1

Design Flow 150 gpm

Design Pressure 200 psig

Design Temperature 220qF

Temperature Transient Design for an Increase From 60qF to 212qF in 5 Seconds

Resin Equivalent Capacity Mixture of Nuclear Grade Cation and Anion DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-7 Revision 36 Page 4 of 4

SPENT FUEL POOL COOLING SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

Material Type 304 Stainless Steel for Vessel and Integral Parts

Codes ASME B&PV Code,Section III, Class C and ASME B&PV Code,Section VIII, Par UW2 (a)

6. Piping, Fittings and Valves

Material Stainless Steel

Design Pressure 125 psig

Design Temperature 150qF

Joints, 2 in and Larger ButtWelded Except at Flanged Equipment

1-1/2 in and Smaller Socket Welded Except at Flanged Equipment

Valves, 2 in and Larger Stainless Steel, Butt Weld Ends, 150#

11/2 in and Smaller Stainless Steel, Socket Weld Ends, 150#

Butterflies, All Sizes Stainless Steel Flanged, 150#

Code ASA B31.1

Welds 100% Radiographically Checked

7. Spent Fuel Pool

Volume of Empty SFP Cavity 21,885 ft3

Volume of Empty North Tilt Pit Cavity 4,095 ft3 DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 1 of 5

INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

1. Instrument Air System
a. Air Compressors

Type Rotary Screw, Oil Free, Air Cooled

Number 3

Design Capacity (Each) 288 scfm

Design Pressure 125 psig

Main Motor (Compressor) 75 hp, 3 Ph, 60 Hz, 460 V

Fan Motor 5 hp, 3 Ph, 60 Hz, 460 V

Code Motor, NEMA

b. Aftercoolers
1. Type Shell and Tube

Number 3 (1 per Compressor)

2. Type Cooling Coil

Number 3 (1 per Compressor - onboard)

c. Air Receivers

Type Vertical

Number 3

Design Pressure 125 psig

Capacity 57 ft3

Code ASME B&PV Code,Section VIII

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 2 of 5

INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

d. Air Dryer

Type Silica Gel Absorbent, Electric Heater Reactivated

Number 1

Capacity 205 scfm Outlet Moisture Content With Saturated Air Inlet -40°F Dew Point at 100 psig

Code ASME B&PV Code,Section VIII

e. Piping and Valves

Upstream of Dryer Carbon Steel Piping and CI, or Bronze Valves

Downstream of Dryer Copper Piping and Bronze or Stainless Steel Valves Except at Containment Penetration and at Isolation Valves (Carbon Steel)

Code ASA B31.1

2. High Pressure Air System
a. Air Compressors

Type Single Acting, Air Cooled

Number 3

Design Capacity (Each) 22.3 scfm

Design Pressure 325 psig

Motor 10 hp, 440 V, 3 Phase

Code Motor, NEMA

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 3 of 5

INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

b. Air Dryer

Type Desiccant

Number 3 (1 per Compressor)

Capacity (Each) 35 scfm

Dewpoint -40 °F at 350 psig

Code ASME B&PV Code,Section VIII

c. Air Receivers

Type Horizontal

Number 3 (1 per Compressor)

Design Pressure 350 psig

Capacity 60 ft3

Code ASME B&PV Code,Section VIII

d. Aftercoolers

Number 3 (1 per Compressor)

Type Air Cooled

e. Piping

Material Carbon Steel

Code ASA B31.1 (Seismic Class I Supported From Receivers to Operators on Engineered Safe-guards Systems)

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 4 of 5

INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

3. Feedwater Purity Air System
a. Air Compressors

Type Two stage air screw, oil free

Number 2

Design Capacity (Each) 297 scfm

Design Pressure 117 psi

Motor 75 hp, 460 V, 3 Phase

Air Dryer (Integral to Compressor)

Type Refrigerant

Power Consumption (at full load) 1.6 kW

Pressure 102 psig

Dew Point 37.4°F @ 68°F/100% RH

c. Aftercooler

Number 2

Type Air Cooled

d. Receiver

Type Vertical

Number 1

Design Pressure 150 psig

Design Temp 100°F

Capacity 1060 gal

Code ASME B&PV Code,Section VIII

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-8 Revision 36 Page 5 of 5

INSTRUMENT AIR SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

4. Nitrogen Backup Stations
a. Nitrogen Bottles

Pressure (nominal) 2400 psig

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-9 Revision 36 Page 1 of 2

EFFECT OF LOSS OF AIR TO AIR-OPERATED VALVES

Position Safety (a) After Loss No Valve Description Position of Air

Service Water System

CV-0821 CCW Heat Exchanger Temp Control C C CV-0822 CCW Heat Exchanger Temp Control C C CV-0823 Component Cool HX Dischg O O CV-0824 Return From Containment Coolers O/C O CV-0825 Eng Safe Room Cooler Supply O O CV-0826 Component Cool HX Dischg O O CV-0844 Critical Service Wtr Header Iso O O CV-0845 Critical Service Wtr Header Iso O O CV-0846 Critical Service Water Header Cross Connect O O CV-0847 Supply to Containment Coolers O O CV-0857 Critical Service Water Header Cross Connect O O CV-0861 8" Return From Cont Coolers O O CV-0862 Containment Cooler Supply O O CV-0864 8" Return From Cont Coolers O O CV-0865 Containment Cooler Supply O O CV-0867 8" Return From Cont Coolers O O CV-0869 Containment Cooler Supply C C CV-0870 Containment Cooler Supply O O CV-0873 8" Return From Cont Coolers O O CV-0876 Diesel Generator Cool Supply O O CV-0877 Diesel Generator Cool Supply O O CV-0878 Eng Safe Room Cooler Supply O O CV-0879 Backup Cool Safeguards Pumps C C CV-0880 Backup Cool Safeguards Pumps C C CV-0884 Diesel Generator Cool Supply O O CV-0885 Diesel Generator Cool Supply O O CV-1318 Service Water Pump Header Iso O O CV-1319 Service Water Pump Header Iso O O CV-1359 Noncritical Service Water Header Isolation C C CV-1655 Control Room HVAC Service Water O O CV-1656 Control Room HVAC Service Water O O

(a) Safety position is maintained in this table, but safety is no longer applicable as none of the systems are safety-related.

O Open C Closed DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-9 Revision 36 Page 2 of 2

EFFECT OF LOSS OF AIR TO AIR-OPERATED VALVES

Position Safety (a) After Loss No Valve Description Position of Air

Component Cooling System

CV-0915 Comp Cool Surge Tank Vent C C CV-0944 Supply to Radwaste Evaporator C C CV-0944A Supply to Spent Fuel HX C C CV-0945 Supply to Comp Cool HX O O CV-0946 Supply to Comp Cool HX O O CV-0977B Return From Radwaste Evaporator C C

Radioactive Waste Treatment System

CV-1001 Primary System Drain Tank Recirc C C CV-1002 Primary System Drain Tank Outlet C C CV-1004 Degasifier Pump Discharge C C CV-1007 Primary System Drain Tank Outlet C C CV-1036 Pump P-70 Inlet C C CV-1037 Clean Waste Tank Recirc C C CV-1038 Pump P-70 Inlet C C CV-1044 Pump P-69 A/B Suction C C CV-1045 Pump P-69 A/B Suction C C CV-1064 Clean Waste Tank Vent C C CV-1065 Clean Waste Tank Vent C C CV-1101 Waste Gas Surge Tank Vent C C CV-1102 Waste Gas Surge Tank Vent C C CV-1103 Containment Sump Drain C C CV-1104 Containment Sump Drain C C

(a) Safety position is maintained in this table, but safety is no longer applicable as none of the systems are safety-related.

O Open C Closed

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-11 Revision 36 Page 1 of 3

FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

1. Fire Pump, Motor Driven

Type Vertical Turbine

Number 1

Capacity 1,500 gpm

Discharge Pressure 125 psig

Material

Discharge Head Cast Iron

Impeller Bronze

Motor 150 hp, 460 V, 3 Ph, 60 Hz

Codes Underwriters Lab Label Motor, NEMA; Pump, Standards of Hydraulic Institute

2. Fire Pump, Diesel Engine Driven

Type Vertical Turbine

Number 2

Capacity 1,500 gpm

Discharge Pressure 125 psig

Material

Discharge Head Cast Iron

Impeller Bronze

Gear Drive Reduction Ratio 1:1, 200 hp Rating

Diesel Engine 150 hp

Codes Underwriters Lab Label Diesel Engine, NEMA; Pump, Standards of Hydraulic Institute DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-11 Revision 36 Page 2 of 3

FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

3. Fire System Jockey Pump

Type Vertical Turbine

Number 1

Capacity 50 gpm

Discharge Pressure 117 psig nominal

Material

Discharge Head Fabricated Steel

Impellers Bronze

Motor 7-1/2 hp, 460 V, 3 PH, 60 Hz

Codes Motor, NEMA; Pump Standards of Hydraulic Institute

4. Piping, Fittings and Valves
a. To Auxiliary Feedwater Pump Suction Header and Critical Service Waterlines

Material Seamless Carbon Steel

Design Pressure 125 psig

Design Temperature 100°F

Construction Butt-Welded Except at Flanged Equipment

Valves Carbon Steel, Butt-Weld Ends, 150#,

or Cast Iron, Flanged End, 175#,

Underwriters lab Label

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-11 Revision 36 Page 3 of 3

FIRE PROTECTION SYSTEM DESIGN RATINGS AND CONSTRUCTION OF COMPONENTS

b. To Spent Fuel Pool Blind Flange and Normal Fire Protection Service

Underground Aboveground

Material Original-Cast Iron Carbon Steel (150# Class)

Replacement-Ductile Iron (350# Class)

Design Pressure 150 psig 125 psig

Design Temperature 100°F 100°F

Construction Original-Mechanical Joint Butt-Welded Except at Flanged Equipment

Replacement-Push-on Joint

Valves Original-Cast Iron, Cast Iron, Flanged Mechanical Joint, End, 175#,

175#, Underwriters Underwriters Lab Lab Label Label

Replacement-Ductile Iron, Mechanical Joint, 250#, UL Listed, FM Approved

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 1 of 4

AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS

1. Motor-Driven Auxiliary Feedwater Pump (P-8A)

Type Horizontal Centrifugal, With Packed Glands

Number 1

Material

Case 4.6% Chrome Alloy Steel

Impeller Bronze

Shaft 11%-13% Chrome Alloy Steel

Motor 450 hp, 3 Ph, 60 Hz, 2,300 V

Codes Motor, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965

2. Turbine-Driven Auxiliary Feedwater Pump (P-8B)

Type Horizontal Centrifugal, With Packed Glands

Number 1

Material

Case 4.6% Chrome Alloy Steel

Impeller Bronze

Shaft 11%-13% Chrome Alloy Steel

Turbine Single Stage, Axial Flow, Exhaust to Atmosphere, 450 hp

Codes Turbine, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 2 of 4

AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS

3. Motor Driven Auxiliary Feedwater Pump (P-8C)

Type Horizontal Centrifugal, With Mechanical Seals

Number 1

Material

Case 18 Cr, 8 Ni Stainless Steel

Impeller 12 Cr Stainless Steel

Shaft 12 Cr, 0.6 Mo Stainless Steel

Motor 400 hp, 3 Ph, 60 Hz, 2,300 V

Codes Motor, NEMA; Pump, Standards of Hydraulic Institute, 11th Edition, 1965

4. Piping and Valves for P-8A, P-8B, and P-8C
a. Pump Suction

Underground Aboveground

Material 304 Stainless Steel Carbon Steel

Construction Welded Except at Flanged Equipment Connections

Valves 2-1/2 in and Larger - Carbon Steel, Butt-Welded, 150#

Valves 2-1/2 in and Smaller - Carbon Steel, Socket Welded, 600#

Code ASA B31.1-1955 ASA B31.1-1955 ASA B16.5-1961 ASA B16.5-1961

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 3 of 4

AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS

b. Pump Discharge

Underground Aboveground

Material 304 Stainless Steel Carbon Steel

Upstream Downstream of FW of FW Control Control Valve Valve

Construction Welded Except at Flanged Equipment Only

Valves 2-1/2 in and Larger - Carbon Steel, Butt-Welded, 600#

Valves 2-1/2 in and Smaller - Carbon Steel, Socket Welded, 600#

Code ASA B31.1-1955 ASA B31.1-1955 ASA B16.5-1961 ASA B16.5-1961

c. Auxiliary Turbine Steam Supply

Piping and Valves Same as for Aboveground Pump Discharge Piping

5. Diesel-Driven Auxiliary Feedwater Pump (P-8D)

Type Horizontal Centrifugal, with Mechanical Seals

Number 1

Diesel Engine (K-17) 800 hp, Starter with Storage Batteries

Codes NFPA 20, NFPA 37, UL 1247

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-12 Revision 36 Page 4 of 4

AUXILIARY FEEDWATER SYSTEM CONSTRUCTION OF COMPONENTS

6. Piping and Valves for P-8D
a. Pump Section

Underground Aboveground

Material 304 Stainless Steel Carbon Steel

Construction Welded Except at Flanged Equipment Connections

Valves 2-1/2 in and Larger Carbon Steel, Butt-Welded, 150#

Valves 2-1/2 in and Smaller Carbon Steel, Butt-Welded, 600#

Code ASA B31.1 1-2012 for procurement ASA B31.1 1-1973 for qualification

b. Pump Discharge

Underground Aboveground

Material 304 Stainless Steel Carbon Steel

Construction Welded, Except Flanged at Material Transition

Valves 2-1/2 in and Larger Carbon Steel, Butt-Welded, 900#

Valves 2-1/2 in and Smaller Carbon Steel, Butt-Welded,1500#

Code B31.1 (1973) B31.1 (1973)

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-14 Revision 36 Page 1 of 3

CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA

Makeup/Recirculation Air Filter Units

Quantity Two - 100% Capacity Each

Capacity 3,200 ft3/min

Filters (per Filtering Unit)

Prefilter Quantity 3 Media Glass Fiber or Knitted Pad

HEPA Filter Quantity 3 Upstream Filters 3 Downstream Filters Media Glass Fiber

Charcoal Filter Trays Quantity 18 [2 Banks of 9]

Media Activated Carbon, 4 in. Bed Depth (Two-2 inch deep Trays in Series)

Fan Type Vaneaxial

Fan Static Pressure at Rating, in wg 10 in

Motor 20 hp, 460 V, 3 Ph

Filter Test Efficiency HEPA 99.97% of Particulate Carbon Adsorber 99.9% of Elemental Iodine Electric Heating Coil Type Nickel/Chromium Capacity 15 kW, 480 V, 3 Ph

Air Filter Unit Assembly

' P of wg 8.00 in (Maximum)

NOTE: All electrical equipment is Class 1E unless otherwise noted.

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-14 Revision 36 Page 2 of 3

CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA

Air Handling Unit V-95 or V-96

Type Package (Filter, Cooling Coil, Fan)

Capacity 12,500 ft3/min

Cooling Coil Type Direct Expansion Refrigerant Capacity (Total) 603,500 Btu/h

Heating Coil (Nonclass 1E)

Type 80% Nickel and 20% Chromium Capacity 177 kW, 480 V, 3 Ph

Fan Type Centrifugal Total Pressure, wg 3.85 in Motor 25 hp, 460 V, 3 Ph

Filter Type, Media 6 in Thick Moderate Efficiency Prefilter P of wg (Clean) 0.25 in

Refrigerant Condensing Unit

Type Water-Cooled Reciprocating

Refrigerant R-22

Compressor Type Reciprocating, 4 Cylinder Motor 60 hp, 460 V, 3 Ph

Capacity 554,400 Btu/h @ 85 °F, 39 gpm Service Water

Condenser Water Flow Set per RO-216

NOTE: All electrical equipment is Class 1E unless otherwise noted.

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-14 Revision 36 Page 3 of 3

CONTROL ROOM HVAC SYSTEM MAJOR COMPONENT DESIGN DATA

Smoke Purge Exhaust Fan V-94 (Nonclass 1E)

Type Vaneaxial

Capacity 7,800 ft3/min

Motor 7-1/2 hp, 460 V, 3 Ph

Exhaust Fan V-16 (Existing)

(Nonclass 1E)

Type Centrifugal

Capacity 160 ft3 /min

Motor 1/12 hp, 120 V, 1 Ph

Humidifiers VH-12 and VH-13 (Nonclass 1E)

Type Steam Generator

Capacity 50 lb/h (17 kW, 480 V, 3 Ph)

NOTE: All electrical equipment is Class 1E unless otherwise noted.

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-16 Revision 36 Page 1 of 1

SAMPLING STATIONS

NSSS Sampling Station

Containment Hydrogen Monitoring System

Turbine Analyzer Panel

Radwaste Sampling Station

Waste Gas Sample Panel

Radwaste Addition Sampling System

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-17 Revision 36 Page 1 of 1

SAMPLE POINT

SUMMARY

1. Radwaste Sampling Station

Primary System Drain Tank Recirc Grab Sample Equipment Drain Tank Recirc Grab Sample Vacuum Degasifier Pump Discharge Grab Sample Receiver Tank Pumps Discharge Grab Sample Receiver Tank Circ Pumps Discharge Grab Sample Radwaste Demin Tanks Outlet (3) Grab Sample Treated Waste Mon Tanks Recirc (2) Grab Sample Controlled Chem Lab Drain Tank Grab Sample Filtered Waste Monitor Tank Recirc Grab Sample Dirty Waste Drain Tank Recirc Grab Sample Component Cooling Pumps Discharge Grab Sample

2. Waste Gas Sample Panel

Volume Control Tank Bomb Waste Gas Surge Tank Bomb Waste Gas Decay Tanks (6) Bomb Spurt Resin Storage Tank Bomb

3. Radwaste Addition Sampling System

Radwaste Polishing Demineralizer Discharge Grab Sample, Conductivity Clean Waste Transfer Pump Discharge Grab Sample Clean Waste Distillate Pump Discharge Grab Sample Misc Waste Distillate Pumps Discharge (2) Grab Sample Misc Waste Demineralizer Tank Discharge (2) Grab Sample, Conductivity (1)

Misc Waste Transfer Pumps Discharge (2) Grab Sample Misc Waste Filter Inlet Grab Sample Misc Waste Filter Discharge (2) Grab Sample Primary System Makeup Water Pump Discharge Grab Sample Utility Water Transfer Pump Discharge Grab Sample Spurt Resin Storage Tank Gas Bomb Waste Gas Decay Tanks (3) Bomb Radwaste Evaporator Distillate (2) Grab Sample

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 1 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.1 Regenerative Heat Exchanger - E-56

Quantity 1

Type Shell and Tube, Vertical

Normal Heat Transfer 6.6 x 106 Btu/h

Code ASME B&PV Code,Section III, Class C, 1965

Shell Side (Charging)

Fluid 15,000 ppm Boric Acid, Maximum (Design)

Design Pressure 2,735 psig

Design Temperature 650qF

Material Stainless Steel

Tube Side (Letdown)

Fluid 15,000 ppm Boric Acid, Maximum (Design)

Design Pressure 2,485 psig

Design Temperature 650qF

Material Stainless Steel

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 2 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.2 Letdown Orifice - RO-2003, RO-2004 and RO-2005

Quantity 3

Capacity (Each) 40 gpm

Design Pressure 2,485 psia

Design Temperature 650qF

Material Stainless Steel

1.3 Letdown Heat Exchanger - E-58

Quantity 1

Type Shell and Tube, Horizontal

Design Heat Transfer 19.1 x 106 Btu/h

Code ASME B&PV Code,Section III, Class C Tube Side (Letdown)

Fluid 15,000 ppm Boric Acid, Maximum (Design)

Design Pressure 650 psig

Design Temperature 550qF

Material Stainless Steel

Shell Side (Cooling Water)

Fluid Component Cooling Water

Design Pressure 150 psig

Design Temperature 250qF DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 3 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

Material Carbon Steel

1.4 Process Radiation Monitor - Element RE-0202

Quantity 1

Design Pressure 200 psig

Design Temperature 250qF

Code ASA B31.1

1.5 Ion Exchangers - T-51A, T-51B and T-52

Quantity 3

Type Flushable

Design Pressure 200 psig

Design Temperature 250qF

Resin Volume 32 ft 3

Retention Screen 80 US Mesh

Code for Vessel ASME B& PV Code,Section III, Class C

Material Stainless Steel

Fluid 15,000 ppm Boric Acid, Maximum (Design)

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 4 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.6 Purification Filter s - F-54A and F-54B

Quantity 2

Type of Elements Synthetic Fiber

Retention 0.05 to 6.0 Micron Absolute; 1.0 Micron Nominal (or finer)

Design Pressure 200 psig

Design Temperature 250qF

Design Flow 120 gpm

Code for Vessel ASME B& PV Code,Section III, Class C, 1965

Material Stainless Steel

Fluid 15,000 ppm Boric Acid, Maximum (Design)

1.7 Volume Control Tank - T-54

Quantity 1

Type Vertical, Cylindrical

Design Pressure, Internal 75 psig

Design Pressure, External 15 psig

Design Temperature 250qF

Internal Volume, Minimum 4,170 gal

Code ASME B&PV Code,Section III, Class C, 1965

Material Stainless Steel

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 5 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.8 Spray Nozzle (Volume Control Tank)

Quantity 1

Type Medium Angle, Full Cone

Design Pressure 200 psig

Design Temperature 250qF

Maximum Spray Flow 120 gpm

Material Stainless Steel

1.9 Variable Speed Char ging Pump - P-55A

Quantity 1

Type Positive Displacement

Design Pressure 2,735 psig

Design Temperature 250qF

Maximum Discharge Pressure (Short Term) 2,900 psig

NPSH Required 7.65 ft (Ref. 25)

Maximum Pressure Pump Starts Against 2,485 psig

Driver Rating 100 hp

Type Variable Capacity Device Fluid Drive

Materials in Contact With Pum ped Stainless Steel or Equivalent Fluid Corrosion Resistance

Fluid 12 Wt% Boric Acid, Maximum (Design)

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 6 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.10 Constant Speed Charging Pumps - P-55B and P-55C

Quantity 2

Type Positive Displacement

Design Pressure 2,735 psig

Design Temperature 250qF

Flow Rate 40 gpm

Maximum Discharge Pressure (Short Term) 3,010 psig

NPSH Required 7.41 ft (Ref. 25)

NPSH Available P-55B/C 28.22/28.18 ft (Ref. 25)

(Normal Suction From VCT)

Maximum Pressure Pump Starts Against 2,500psig

Driver Rating 75 hp

Pump Cooling Water Requirements 5 gpm, 15 qF Rise

Fluid 12 Wt% Boric Acid, Maximum (Design)

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 7 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.11 Boric Acid Batching Tank - T-77

Quantity 1

Internal Volume 580 gal

Design Pressure Atmospheric

Design Temperature 200qF

Type Heater Electric Immersion

Heater Capacity 31.5 kw Minimum

Code ASME B&PV Code,Section VIII

Fluid 12 Wt % Boric Acid, Maximum (Design)

Material Stainless Steel

1.12 Boric Acid Strainer - F-10 (YS-0224)

Quantity 1

Type Basket

Design Pressure 125 psig

Design Temperature 250qF

Screen Size 100 x 100 US Mesh

Design Flow 50 gpm

Material Stainless Steel

Fluid 12 Wt % Boric Acid, Maximum (Design)

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 8 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.13 Concentrated Boric Acid Storage Tanks - T-53A and T-53B

Quantity 2

Internal Volume 6,550 gal

Design Pressure Atmospheric

Design Temperature 200qF

Type Heater Electrical, Dry Well Installation

Heater Capacity Two Independent 4 kW Banks per Tank

Fluid 12 Wt % Boric Acid, Maximum (Design)

Material Stainless Steel

Code ASME B&PV Code,Section III, Class C, 1965

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 9 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

1.14 Boric Acid Pumps - P-56A and P-56B

Quantity 2

Type Centrifugal

Design Pressure 150 psig

Design Temperature 250qF

Design Head 225 ft

Design Flow 143 gpm

NPSH Required 7.50 ft (Ref. 25)

NPSH Available P-56A/B 25.06/25.23 (Ref. 25)

Horsepower 30

Fluid 12 Wt % Boric Acid, Maximum (Design)

Material in Cont act With Liquid Stainless Steel

1.15 Boric Acid Filter - F-9

Quantity 1

Type Elements Synthetic Fiber

Retention of 5 Micron Particles 98%

Design Pressure 150 psig

Design Temperature 250qF DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 10 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

Design Flow 140 gpm

Material Stainless Steel

Liquid 12 Wt % Bo ric Acid, Maximum (Design)

Code ASME B&PV Code,Section III, Class C, 1965

1.16 Chemical Addition Tank - T-56

Quantity 1

Capacity 10.5 gal

Design Pressure Atmospheric

Design Temperature 200qF

Material Stainless Steel

Fluid Hydrazine (N2H4), LiOH, KOH, NH4OH

Code ASME B&PV Code,Section VIII

1.17 Chemical Addition Strainer - F-58

Quantity 1

Type Basket

Design Pressure 100 psig

Design Temperature 250qF

Screen Size 60 US Mesh DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-18 Revision 36 Page 11 of 11

CHEMICAL AND VOLUME CONTROL SYSTEM DESIGN PARAMETERS

Design Flow 30 gph

Material Stainless Steel

Fluid Hydrazine (N2H4), LiOH, KOH, NH4OH

1.18 Metering Pump - P-57

Quantity 1

Type Air Operated Double Diaphragm

Design Pressure 120 psig

Design Temperature 190qF

Design Flow Rate 0 to 35 gpm

Design Air Consum ption 0 to 50 scfm

Material Stainless Steel

Fluid Hydrazine (N2H4), LiOH, KOH, NH4OH DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-19 Revision 36 Page 1 of 1

FUEL HANDLING DATA

1. New Fuel Storage Rack

Core Storage Capacity 1/6

Equivalent Fuel Assemblies 36

Center-to-Center Spacing of Assemblies 11 in

2. Spent Fuel Storage Pool

Core Storage Capacity 4.3

Equivalent Fuel Assemblies 892

Number of Space Accommodations for Spent Fuel Shipping Casks 1

Center-to-Center Spacing of Assemblies Region 1 10-1/4 in Region 2 9.17 in

Maximum keff With Unborated Water Less Than 1.0

3. Miscellaneous Details

Wall Thickness for Spent Fuel Storage Pool 4 ft to 6-1/2 ft

Weight of Fuel Assembly 1,500 lb

Capacity of Refueling Water Storage Tank 285,000 gal

Quantity of Water Required for Fuel Handling 250,000 gal

DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-20 Revision 36 Page 1 of 2

FUEL BUILDING CRANE

Main Hoist 3 ft/min at Full Load (3 Steps), 25 hp at 900 r/min

Main Hoist Brake Capacity 179 ft-lb

Auxiliary Hoist 25 ft/min at Full Load (Stepless), 25 hp at 900 r/min

Trolley 25 ft/min at Full Load (3 Steps), 3 hp at 1,800 r/min

  • Bridge 25 ft/min at Full Load (3 Steps), 5 hp at 1,800 r/min
  • Service Class Class A, Electric Overhead Crane Institute Specification 70

Lift Main Hoist 54 ft 0 in

Lift Auxiliary Hoist 108 ft 5 in

Span 44 ft 10 in Center-to-Center Rails

Bridge Travel Approximately 100 ft

Lifting Tackle Main Hoist - Rope 16 Parts 13/4-Inch SS, Drum 521/2-Inch Pitch Diameter, Sheaves 28-Inch Pitch Diameter

Auxiliary Hoist - Rope 4 Parts 3/4-Inch SS, Drum 15-Inch Pitch Diameter, Sheaves 13-Inch Pitch Diameter

Girders Welded Box Section

Runway Rail 100 lbs ASCE

Trolley Rail 175 lbs USS

Bridge Drive Direct Drive Arrangement With Oiltight Center Gear Case

Trolley Drive Direct Drive Arrangement With Oiltight Center Gear Case

  • Single failure proof mode of operation only DSAR CHAPTER 9 - AUXILIARY SYSTEMS TABLE 9-20 Revision 36 Page 2 of 2

FUEL BUILDING CRANE

Capacity in Net Tons Bridge 110 Tons, Main Hoist 110 Tons, Auxiliary Hoist 15 Tons

Wheels Bridge Has Eight 21-Inch Steel Hardened Treads

Trolley Has Four 21-Inch Diameter Steel Hardened Treads

Bridge End Assembly Rotating Axle

Bumpers Rubber

Bearings Antifriction Throughout

Gearing Helical Gearing Heat-Treated Steel Throughout Except Trolley Traverse. All Gearing in Oiltight Casing