February 12, 2021


'RFNHW1R                                                               1/
              

861XFOHDU5HJXODWRU\&RPPLVVLRQ
$771'RFXPHQW&RQWURO'HVN
:DVKLQJWRQ'&

                            -RVHSK0)DUOH\1XFOHDU3ODQW+/-8QLW
          ,QVHUYLFH,QVSHFWLRQ3URJUDP2ZQHU¶V$FWLYLW\5HSRUWIRU2XWDJH5

/DGLHVDQG*HQWOHPHQ

7KH$60(6HFWLRQ;,&RGH&DVH12$52ZQHU¶V$FWLYLW\5HSRUWIRUWKH5
5HIXHOLQJ2XWDJHLVSURYLGHGDVDQHQFORVXUHWRWKLVOHWWHU7KH2$55HSRUWLQWKH
HQFORVXUHLQFOXGHVWKH2$5)RUPDVZHOODV7DEOH³,WHPVZLWK)ODZVRU5HOHYDQW
&RQGLWLRQV7KDW5HTXLUHG(YDOXDWLRQIRU&RQWLQXHG6HUYLFH'ZKLFKOLVWVHYDOXDWLRQV
SHUIRUPHGIRUFRQWLQXHGVHUYLFHDQG7DEOH$EVWUDFWRI5HSDLU5HSODFHPHQW$FWLYLWLHV
5HTXLUHGIRU&RQWLQXHG6HUYLFHZKLFKOLVWVUHSDLUUHSODFHPHQWDFWLYLWLHV

7KLVUHSRUWLVIRUWKHILUVWSHULRGRIWKHWK,QWHUYDO,6,DFWLYLWLHV ,QWHUYDO3HULRG
2XWDJH 

7KLVOHWWHUFRQWDLQVQR15&FRPPLWPHQWV,I\RXKDYHDQ\TXHVWLRQVSOHDVHFRQWDFW
-DPLH&ROHPDQDW

5HVSHFWIXOO\VXEPLWWHG




&KHU\O$*D\KHDUW
5HJXODWRU\$IIDLUV'LUHFWRU
&$*GVSFEJ

(QFORVXUH    5)RUP2$52ZQHU¶V$FWLYLW\5HSRUW



FF5HJLRQDO$GPLQLVWUDWRU5HJLRQOO
      1553URMHFW0DQDJHU+/-)DUOH\1XFOHDU3ODQW
      6HQLRU5HVLGHQW,QVSHFWRU+/-)DUOH\1XFOHDU3ODQW
      57<3(&)$

 














                -RVHSK0)DUOH\1XFOHDU3ODQW+/-8QLW
  ,QVHUYLFH,QVSHFWLRQ3URJUDP2ZQHU&#xb6;V$FWLYLW\5HSRUWIRU2XWDJH5
                                  
(QFORVXUH
                                  
                5)RUP2$52ZQHU&#xb6;V$FWLYLW\5HSRUW

 
(QFORVXUHWR1/
5)RUP2$52ZQHU&#xb6;V$FWLYLW\5HSRUW FORM OAR-1 OWNER'S ACTIVITY REPORT st...:.P....:e=r.:.:io=d=*--=2=-n_d..:..R.:.:e""p=o=rt...,)._________________
Report Number _ _-=2'--'-5=--.. .:1. . ;-2=.. ., (-=Uc:. n""'it:. . :2=., c. :5=-t_h..:.:ln.:.:t=e.:...rv..,a=l1.,_. :. 1_
Plant  -----=J=o~se=--p=h~M~*....:F....:a=r~le"""y....;N~u ~cl=e~a~r~P~la=n~t~---------------------
Unit No. _ _ ___.2,....__ __                      Commercial service date                                                      December 01, 1977                                                      Refueling outage no. -=2=R-"2=7"'------
(if applicable)
Current inspection interval _ _. , 5:.th. _________________________ _________
(1st, 2nd, 3rd, 4th, other)
Current inspection period _ ____,,1_                st_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
(1st, 2nd, 3rd)
Edition and Addenda of Section XI applicable to the inspection plans:                                                                                            The 2007 Edition through 2008 Addenda is applicable to the 5th Inspection Interval.
Date and revision of inspection plans: 5th Inspection Interval Inspection Plans - Volume 1- 10/11/2020 (Version 5.0}, Volume 3 - 10/9/2020 (Version 3.0}, Volume 4 - 8/1/2019 (Version 2.0}, and Volume 5 - 12/19/2019 (Version 2.0}. 2R27 Outage Plan - 10/8/2020 (Version 1.0} with 2R27 Outage Plan Scope Change SC-004
  - 11/20/2019 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans:                                                                                                                            Same Code Cases used for inspection and evaluation:                                                    N-716-1, N-722-1, N-776, N-513-4, N-532-5, N-648-2, and N-770-5 (if applicable, including cases modified by Case N-532 and later revisions)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of_ _--'2='-R=2=7______
conform to the requirements of Section XI.                                                                                                                                                                              (refueling outage number)
Signed      R. M. McAdams                c;;?~
Owner or Owner's Designee, Title Engineering Director                                                      Date  02/~e::e;e: /
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Hartford. CT. have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any man~ny personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Rodney S e n n ~ ~ ~                                                                                                        Commission                  _1:. :2=6::. :0: . :3ee.. .: C:. . l:. .;N:. . :. . :R_,____________
Inspector's S i g n ~                                                                                                                        (National Board Number and Endorsement)
Date _D_Z-_/........,0..."5"'=--,._/_2--0
__Z-I_ _ _ __
(
 
(QFORVXUHWR1/
5)RUP2$52ZQHU&#xb6;V$FWLYLW\5HSRUW Table 1 Items with Flaws or Relevant Conditions That Required Evaluation for Continued Service Examination            Item Description                        Evaluation Description Category and Item Number D-B                    Service Water leak on 2A Service        CR 10633466 documents the D2.10                  Water Pump vent line. There was a        evaluation for operability, resulting in through wall leak identified upstream of Operable But Degraded / Non-the vacuum breaker Q2P16V580 and        conforming due to the leak on ASME vent valve Q2P16V585. The leak was      Class 3 piping. The location was too small to be measurable. The leak    isolated until the piping was replaced by location is on the bottom side of the    work order SNC1038624.
piping where it contacts the pipe support.
D-B                    A through-wall leak was discovered on    CR 10633640 documents the D2.10                  a 6 inch diameter piping portion of the  evaluation for operability, resulting in 2C Service Water pump mini-flow line    Operable But Degraded / Non-approximately 3 inches downstream of    conforming due to the leak on ASME mini-flow isolation valve Q2P16V575. Class 3 piping. The location was The leak rate could not be measured      isolated until the piping was replaced by but is described as very small (the      work order SNC930315.
affected pipe had a wet spot, but no drops were observed during the visual inspection period; <1 dpm)
D-B                    A through-wall leak was noted on the    CR 10739161 documents the D2.10                  2A Residual Heat Removal (RHR)          evaluation for operability, resulting in Engineered Safeguards Feature (ESF)      the 2A RHR Room Cooler being Room Cooler Q2E16H003A Service          declared Inoperable and the Unit 2 Water piping return line located in the  Service Water declared Operable But 2A RHR Pump Room. The                    Degraded I Non-conforming due to the (approximately 1 drop every 8 minutes)  leak on ASME Class 3 piping. The pinhole leak is coming from the weld    location was isolated and repaired by material adjacent to the flange          work order SNC1118151.
upstream of Q2P16V021A.This was identified during the ISi pressure test 160.27-2.
D-B                    A through-wall leak was noted on the    CR 10742390 documents the D2.10                  Service Water return piping from the 2B  evaluation for operability, reference Diesel Generator near the flange        PDO 2-20-01. The flaw was evaluated upstream of valve 01P16V593. This        in accordance with Code Case N-513-was identified during the Unit 2 ISi    4, reference Request for Engineering pressure test 160.28-3.                  Review (RER) SNC1121545-01, and the impacted piping was replaced by work order SNC1121637.
(
 
(QFORVXUHWR1/
5)RUP2$52ZQHU&#xb6;V$FWLYLW\5HSRUW Table 2 Abstract of Repair/ Replacement Activities Required for Continued Service Code      Item Description            Description of Work      Date Completed    Repair/
Class                                                                            Replacement Plan Number 3        2" Service Water piping    Replaced section of      8/29/2019          SNC1038624 upstream of the 2A          leaking Service Water pump vacuum breaker        piping.
O2P16V580 and vent valve O2P16V585 3        6" Service Water piping    Replaced section of      11/10/2020        SNC930315 and of the 2C Service Water    leaking Service Water                      SNC1125762 pump mini-flow line        piping and valve approximately 3 inches    O2P16V578.
downstream of mini-flow isolation valve O2P16V575. Note that during repair, valve O2P16V578 weld end wall thickness was found out of design tolerance, reference CR 10750014 3          1-1/2" 2A RHR ESF          Replaced flange and      9/17/2020          SNC1118151 Room Cooler              weld due to pinhole O2E16H003A Service          leak.
Water piping return line located in the 2A RHR Pump Room.
3          8" Service Water return    Replaced section of      11/6/2020          SNC1121637 piping from the 2B Diesel  leaking Service Water Generator near the        piping.
flange upstream of valve O1P16V593.
(}}

Revision as of 04:55, 18 January 2022

Inservice Inspection Program Owner'S Activity Report for Outage 2R27
ML21043A343
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 02/12/2021
From: Gayheart C
Southern Nuclear Company
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-21-0061
Download: ML21043A343 (5)


Text