{{#Wiki_filter:1) A i , t I ti .COPY 2300 N Street, N.W. Tel 202.663.8000 Washington, D.C. 20037-1 128 F~ax 202.663.8007 www.pillsburylaw.coni MATIAS F. TRAVwEso-DIAZ 202-663-8142 DOCKETED Matias.travieso-diaz@pillsburylaw.comn USNRC March 10, 2009 (3:02pm)March 10, 2009 OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF Alex S. Karlin, Esq., Chairman Administrative Judge .'Atomic Safety and Licensing Board Dr. William H. Reed Mail Stop T-3 F23 Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Mail Stop T-3 F23 Washington, D.C. 20555-0001  
{{#Wiki_filter:1) A     i   ,       t I ti       .                                                           COPY 2300 N Street, N.W.                 Tel 202.663.8000 Washington, D.C. 20037-1 128         F~ax 202.663.8007 www.pillsburylaw.coni MATIAS F. TRAVwEso-DIAZ 202-663-8142                                   DOCKETED Matias.travieso-diaz@pillsburylaw.comn           USNRC March 10, 2009 (3:02pm)
' U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Administrative Judge Dr. Richard E. Wardwell Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 In the Matter of Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc.(Vermont Yankee Nuclear Power Station)Docket No. 50-271-LR; ASLBP No. 06-849-03-LR Gentlemen:
March 10, 2009                                       OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF Alex S. Karlin, Esq., Chairman                   Administrative Judge                 . '
In accordance with the provisions of the Board's Partial Initial Decision (Ruling on Contentions 2A, 2B, 3, and 4), LBP-08-25, 68 N.R.C. (Nov. 24, 2008), slip op. at 67, and the Board's Order (Clarifying Deadline for Filing New or Amended Contentions) (Mar. 9, 2009), Entergy has revised and issued its final calculations of record for the confirmatory environmentally assisted fatigue (CUFen) analyses on the reactor pressure vessel core spray (CS)and recirculation outlet (RO) nozzles at the Vermont Yankee Nuclear Power Station. These revised analyses are presented in the following Structural Integrity Associates, Inc. (SIA)calculations:
Atomic Safety and Licensing Board               Dr. William H. Reed Mail Stop T-3 F23                               Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission               Mail Stop T-3 F23 Washington, D.C. 20555-0001               '     U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Administrative Judge Dr. Richard E. Wardwell Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 In the Matter of Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc.
Calculation No. 0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.303, Revision 1, "Fatigue Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle;" Calculation No.0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle;" and Calculation No. 0801038.306, Revision 1, "Fatigue Analysis of Reactor Recirculation Outlet Nozzle." Calculation 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle" has not been revised so that the version sent to the parties on January 8, 2009 remains the final calculation of record.O37~ T-o-5 March 10, 2009 Page 2 Entergy is serving at this time electronic copies of those analyses on the parties to the above captioned proceeding.
(Vermont Yankee Nuclear Power Station)
Hard copies are also being sent today by overnight mail to the NRC Staff, the New England Coalition and the Vermont Department of Public Service.The methodology applied in the referenced CS and RO confirmatory analyses is in accordance with the approach used in the SIA calculations for the feedwater nozzle that were introduced into evidence in this proceeding, and contains no significantly different scientific or technical judgments from those used in the feedwater nozzle calculations.
Docket No. 50-271-LR; ASLBP No. 06-849-03-LR Gentlemen:
See Calculation 0801038.301 at 4, n.1 and Calculation 0801038.304 at 4, n. 1.As set forth in the referenced revised calculations, the limiting calculated CUFenS for the CS and RO nozzles are less than unity and are therefore acceptable.
In accordance with the provisions of the Board's Partial Initial Decision (Ruling on Contentions 2A, 2B, 3, and 4), LBP-08-25, 68 N.R.C.             (Nov. 24, 2008), slip op. at 67, and the Board's Order (Clarifying Deadline for Filing New or Amended Contentions) (Mar. 9, 2009),
Sincerely, Matias F. Travieso-Diaz Counsel for Entergy cc: Service List Pillsbury Winthrop Shaw Pittman LLP CERTIFICATE OF SERVICE I hereby certify that copies of the foregoing letter were served on the persons listed below by deposit in the U.S. Mail, first class, postage prepaid; where indicated by an asterisk, by electronic mail; and where indicated by a double asterisk, by both overnight and electronic mail, this 1 0 th day of March, 2009.*Administrative Judge Alex S. Karlin, Esq., Chairman Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 ask2(@nrc.gov
Entergy has revised and issued its final calculations of record for the confirmatory environmentally assisted fatigue (CUFen) analyses on the reactor pressure vessel core spray (CS) and recirculation outlet (RO) nozzles at the Vermont Yankee Nuclear Power Station. These revised analyses are presented in the following Structural Integrity Associates, Inc. (SIA) calculations: Calculation No. 0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.303, Revision 1, "Fatigue Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle;" Calculation No.
*Administrative Judge Dr. William H. Reed 1819 Edgewood Lane Charlottesville, VA 22902 whrcville(ieinbarqmail.com
0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle;" and Calculation No. 0801038.306, Revision 1, "Fatigue Analysis of Reactor Recirculation Outlet Nozzle." Calculation 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle" has not been revised so that the version sent to the parties on January 8, 2009 remains the final calculation of record.
*Office of Commission Appellate Adjudication Mail Stop 0-16 C1 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 OCAAmaila~nrc.gov
O37~                                                                               T-o -5
*Lloyd Subin, Esq.*Susan L. Uttal, Esq.*Maxwell C. Smith, Esq.Office of the General Counsel Mail Stop O-15-D21 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 LBS3@(cnrc.gov; susan.uttal(ynrc.gov; maxwell.smith(ai)nrc.
 
gov*Administrative Judge Dr. Richard E. Wardwell Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 rew(anrc.gov
March 10, 2009 Page 2 Entergy is serving at this time electronic copies of those analyses on the parties to the above captioned proceeding. Hard copies are also being sent today by overnight mail to the NRC Staff, the New England Coalition and the Vermont Department of Public Service.
* Secretary Att'n: Rulemakings and Adjudications Staff Mail Stop 0-16 CI U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 secy(anrc.gov, hearingdocket(Dnrc.
The methodology applied in the referenced CS and RO confirmatory analyses is in accordance with the approach used in the SIA calculations for the feedwater nozzle that were introduced into evidence in this proceeding, and contains no significantly different scientific or technical judgments from those used in the feedwater nozzle calculations. See Calculation 0801038.301 at 4, n.1 and Calculation 0801038.304 at 4, n. 1.
gov Atomic Safety and Licensing.Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
As set forth in the referenced revised calculations, the limiting calculated CUFenS for the CS and RO nozzles are less than unity and are therefore acceptable.
**Sarah Hofmann, Esq.Director of Public Advocacy Department of Public Service 112 State Street -Drawer 20 Montpelier, VT 05620-2601 Sarah.hofinann(state.vt.us Pillsbury Winthrop Shaw Pittman LLP  
Sincerely, Matias F. Travieso-Diaz Counsel for Entergy cc: Service List Pillsbury Winthrop Shaw Pittman LLP
**Anthony Z. Roisman, Esq.National Legal Scholars Law Firm 84 East Thetford Road Lyme, NH 03768 aroisman(-,nationalleaalscholars.com
 
**Raymond Shadis 37 Shadis Road PO Box 98 Edgecomb, ME 04556 shadis(lprexar.comr
CERTIFICATE OF SERVICE I hereby certify that copies of the foregoing letter were served on the persons listed below by deposit in the U.S. Mail, first class, postage prepaid; where indicated by an asterisk, by electronic mail; and where indicated by a double asterisk, by both overnight and electronic mail, this 1 0 th day of March, 2009.
*Peter L. Roth, Esq.Office of the New Hampshire Attorney General 33 Capitol Street Concord, NH 03301 Peter.roth(adoi.nh.gov
*Administrative Judge                                    *Administrative Judge Alex S. Karlin, Esq., Chairman                           Dr. Richard E. Wardwell Atomic Safety and Licensing Board                        Atomic Safety and Licensing Board Mail Stop T-3 F23                                        Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission                       U.S. Nuclear Regulatory Commission Washington, DC 20555-0001                                Washington, DC 20555-0001 ask2(@nrc.gov                                            rew(anrc.gov
*Matthew Brock, Esq.Assistant Attorney General Environmental Protection Division Office of the Attorney General One Ashburton Place, 18th Floor Boston, MA 02108 Matthew.Brocke,state.ma.us
*Administrative Judge
*Zachary Kahn, Esq.Atomic Safety and Licensing Board Panel Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 zachary.kalmn(arc.
* Secretary Dr. William H. Reed                                     Att'n: Rulemakings and Adjudications Staff 1819 Edgewood Lane                                       Mail Stop 0-16 CI Charlottesville, VA 22902                               U.S. Nuclear Regulatory Commission whrcville(ieinbarqmail.com                               Washington, DC 20555-0001 secy(anrc.gov, hearingdocket(Dnrc. gov
gov Matias F. avieso-Diaz Pillsbury Winthrop Shaw Pittman LLP V Structural Integrity Associates, Inc. File No.: 0801038.302 CALCULATION PACKAGE Project No.: 0801038 Quality Program E Nuclear E- Commercial PROJECT NAME: VY Confirmatory Analysis for the CS and RO Nozzles CONTRACT NO.: 10163217 Amendment 5 CLIENT: PLANT: Entergy Nuclear Operations, Inc Vermont Yankee Nuclear Power Station CALCULATION TITLE: Stress Analysis of Reactor Core Spray Nozzle Document Affected Project Manager Preparer(s)
*Office of Commission Appellate Adjudication             Atomic Safety and Licensing.Board Mail Stop 0-16 C1                                       Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission                      U.S. Nuclear Regulatory Commission Washington, DC 20555-0001                               Washington, DC 20555-0001 OCAAmaila~nrc.gov
&DocumentsAfted Revision Description Approval Checker(s)
*Lloyd Subin, Esq.                                       **Sarah Hofmann, Esq.
Revision Pages Signature
*Susan L. Uttal, Esq.                                   Director of Public Advocacy
& Date Signatures
*Maxwell C. Smith, Esq.                                 Department of Public Service Office of the General Counsel                             112 State Street - Drawer 20 Mail Stop O-15-D21                                       Montpelier, VT 05620-2601 U.S. Nuclear Regulatory Commission                       Sarah.hofinann(state.vt.us Washington, D.C. 20555-0001 LBS3@(cnrc.gov; susan.uttal(ynrc.gov; maxwell.smith(ai)nrc. gov Pillsbury Winthrop Shaw Pittman LLP
& Date 01 -15 Initial issue.Gary L. Stevens Tyler D. Novotny Computer Files 01/06/09 01/06/09 Jennifer D. Correa.01/06/09 1 1-3,7-8,11 Revised per summary / Preparer: contained in Section 1.1. / &1t@ /Computer Files Changes are marked with revision bars" in right-Stevens hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker: Tim D. Gilman 03/09/09 Page 1 of 15 F0306-O1RO Structural Integrity Associates, Inc.Table of Contents 1.0 O B JE C T IV E .........  
 
.......................................................................................................................
**Anthony Z. Roisman, Esq.                       **Raymond Shadis National Legal Scholars Law Firm                  37 Shadis Road 84 East Thetford Road                            PO Box 98 Lyme, NH 03768                                    Edgecomb, ME 04556 aroisman(-,nationalleaalscholars.com              shadis(lprexar.comr
3 1.1 Changes Made in Revision 1 of this Calculation
*Peter L. Roth, Esq.                             *Zachary Kahn, Esq.
...........................................................
Office of the New Hampshire Attorney General      Atomic Safety and Licensing Board Panel 33 Capitol Street                                Mail Stop T-3 F23 Concord, NH 03301                                U.S. Nuclear Regulatory Commission Peter.roth(adoi.nh.gov                            Washington, DC 20555-0001 zachary.kalmn(arc. gov
3 2.0 METHODOLOGY
*Matthew Brock, Esq.
..............................................................................................................
Assistant Attorney General Environmental Protection Division Office of the Attorney General One Ashburton Place, 18th Floor Boston, MA 02108 Matthew.Brocke,state.ma.us Matias F. Tr*avieso-Diaz Pillsbury Winthrop Shaw Pittman LLP
3 3.0 ASSUMPTIONS
 
/ DESIGN INPUTS .....................................................................................
V StructuralIntegrityAssociates, Inc.
3 4.0 C A L C U L A T IO N S ........................................................................................................................
CALCULATION PACKAGE File No.: 0801038.302 Project No.: 0801038 Quality Program E Nuclear  E-  Commercial PROJECT NAME:
3 4.1 Finite Element Unit Pressure Stress Analysis...............................
VY Confirmatory Analysis for the CS and RO Nozzles CONTRACT NO.:
3 4.2 Thenr al Transient Stress Analysis ................................................................................
10163217 Amendment 5 CLIENT:                                              PLANT:
4 4.3 Determining Critical Stress Paths .................................................................................  
Entergy Nuclear Operations, Inc                      Vermont Yankee Nuclear Power Station CALCULATION TITLE:
.5 4.4 Stress C alculation
Stress Analysis of Reactor Core Spray Nozzle Document      Affected                                          Project Manager            Preparer(s) &
..........................................................................................................
DocumentsAfted                  Revision Description                  Approval                Checker(s)
5 4 .5 P ip in g L o ad s ..............................  
Revision        Pages                                          Signature & Date        Signatures & Date 01            - 15              Initial issue.
............................................................................................
Gary L. Stevens        Tyler D. Novotny Computer Files                                          01/06/09                  01/06/09 Jennifer D. Correa
7 5.0 RESULTS OF ANALYSIS .....................................................................................................
                                                                                              .01/06/09 1        1-3,7-8,11        Revised per summary          /                      Preparer:
8 6.0 R E FE R E N C E S ............................................................................................................................
contained in Section 1.1.                 /    &1t@                          /
8 List of Tables Table 1: Pressure Results (1,000 psi) .............................................................................................
Computer Files  Changes are marked with revision handbars"    in right-Stevens margin.                   03/09/09            Tyler D. Novotny 03/09/09 Checker:
6 Table 2: Stresses Under Unit Pressure Load, psi ...................................
Tim D. Gilman 03/09/09 Page 1 of 15 F0306-O1RO
9 Table 3: Membrane Plus Bending Stresses Due to Piping Loads ................................................
 
10 Table 4: Example Thermal Stress Result Output, psi .....................................................................
StructuralIntegrity Associates, Inc.
11 List of Figures Figure 1. Core Spray Nozzle Internal Pressure Distribution
Table of Contents 1.0    O B JECTIV E ......... .......................................................................................................................          3 1.1      Changes Made in Revision 1 of this Calculation ...........................................................                                       3 2.0 METHODOLOGY ..............................................................................................................                                 3 3.0 ASSUMPTIONS / DESIGN INPUTS .....................................................................................                                           3 4.0 C A LCU L A T IO N S ........................................................................................................................               3 4.1      Finite Element Unit Pressure Stress Analysis...............................                                                                     3 4.2      Thenr al Transient Stress Analysis ................................................................................                             4 4.3      Determining Critical Stress Paths .................................................................................                             .5 4.4      Stress C alculation ..........................................................................................................                  5 4 .5    P ip in g L o ad s .............................. ............................................................................................ 7 5.0    RESULTS OF ANALYSIS .....................................................................................................                              8 6.0    RE FEREN C E S ............................................................................................................................             8 List of Tables Table    1:  Pressure Results (1,000 psi) .............................................................................................                        6 Table    2:  Stresses Under Unit Pressure Load, psi ...................................                                                                         9 Table    3:  Membrane Plus Bending Stresses Due to Piping Loads ................................................                                              10 Table    4:  Example Thermal Stress Result Output, psi .....................................................................                                   11 List of Figures Figure    1. Core Spray Nozzle Internal Pressure Distribution ....................... ................................                                         12 Figure    2. Core Spray Nozzle Pressure Cap Load & Boundary Condition ..................                                                                      13 Figure    3. Core Spray Nozzle Vessel Wall Boundary Condition                                                        ........................               14 Figure    4. Limiting Stress Paths ................................. .....................................................................                   15 FileNo.: 0801038.302                                                                                                                                      Page 2 of 15 Revision: 1 F0306-01RO
.......................  
 
................................
VStructural IntegrityAssociates, Inc.
12 Figure 2. Core Spray Nozzle Pressure Cap Load & Boundary Condition
1.0      OBJECTIVE The objective of this calculation package is to obtain stress distributions for the reactor pressure vessel (RPV) core spray (CS) nozzle at the Vermont Yankee Nuclear Power Station. ANSYS [1]
..................
thernal transient and pressure stress analyses are performed, along with calculation of stresses due to attached piping loads. The stress results will be used for a subsequent ASME Code, Section III NB-3200 [2] fatigue usage calculation.
13 Figure 3. Core Spray Nozzle Vessel Wall Boundary Condition
1.1    Changes Made in Revision 1 of this Calculation Description of changes made in Revision 1 of this calculation:
........................
: a. All changes marked throughout this calculation are editorial changes made to the text of the calculation package.
14 Figure 4. Lim iting Stress Paths .................................  
2.0      METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package
.....................................................................
[3]. A previously developed finite element model (FEM) [3] of the CS nozzle is used to perform thermal and pressure stress analyses using ANSYS [1]. A thermal transient analysis is performed for each defined transient. Concurrent with the thermal transients are pressure and piping interface loads. For these loads, unit load analyses (based on finite element analysis for pressure and manual calculations for attached piping loads) are performed. All six components of the stress tensor are determined in the stress calculations.
15 FileNo.: 0801038.302 Page 2 of 15 Revision:
The fatigue usage calculation and environmental fatigue usage analysis will be performed in a separate calculation package. That subsequent calculation will utilize the thermal and pressure stresses determined in this calculation, along with stresses due to attached piping loads provided in Table 3. The stresses due to pressure and the attached piping loads will be scaled based on the temperature and pressure magnitudes during each individual transient, and the location being analyzed. From the Reference [3] calculation, the FEM includes a factor of two on the modeled RPV radius to account for the 3-D effects of two intersecting cylinders at the nozzle blend radius location.
1 F0306-01RO VStructural Integrity Associates, Inc.1.0 OBJECTIVE The objective of this calculation package is to obtain stress distributions for the reactor pressure vessel (RPV) core spray (CS) nozzle at the Vermont Yankee Nuclear Power Station. ANSYS [1]thernal transient and pressure stress analyses are performed, along with calculation of stresses due to attached piping loads. The stress results will be used for a subsequent ASME Code, Section III NB-3200 [2] fatigue usage calculation.
3.0      ASSUMPTIONS / DESIGN INPUTS Assumptions and design inputs were previously established in Section 3.1 of the Reference [3]
1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision 1 of this calculation:
calculation.
: a. All changes marked throughout this calculation are editorial changes made to the text of the calculation package.2.0 METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package[3]. A previously developed finite element model (FEM) [3] of the CS nozzle is used to perform thermal and pressure stress analyses using ANSYS [1]. A thermal transient analysis is performed for each defined transient.
4.0     CALCULATIONS 4.1 Finite Element Unit Pressure Stress Analysis A uniform pressure of 1,000 psi was applied to the FEM along the inside surface of the CS nozzle and the RPV wall (Figure 1). A pressure load of 1,000 psi was used because it is easily scaled up or FileNo.: 0801038.302                                                                                Page 3 of 15 Revision: 1 F0306-O1RO
Concurrent with the thermal transients are pressure and piping interface loads. For these loads, unit load analyses (based on finite element analysis for pressure and manual calculations for attached piping loads) are performed.
 
All six components of the stress tensor are determined in the stress calculations.
StructuralIntegrityAssociates, Inc.
The fatigue usage calculation and environmental fatigue usage analysis will be performed in a separate calculation package. That subsequent calculation will utilize the thermal and pressure stresses determined in this calculation, along with stresses due to attached piping loads provided in Table 3. The stresses due to pressure and the attached piping loads will be scaled based on the temperature and pressure magnitudes during each individual transient, and the location being analyzed.
down to account for different pressures that occur during transients. In addition, a membrane stress "cap load" was applied to the modeled end of the piping attached to the core spray nozzle safe end.
From the Reference
This membrane stress was calculated as follows:
[3] calculation, the FEM includes a factor of two on the modeled RPV radius to account for the 3-D effects of two intersecting cylinders at the nozzle blend radius location.3.0 ASSUMPTIONS
p* Di2 cap - Do 2 - Di 2 where:
/ DESIGN INPUTS Assumptions and design inputs were previously established in Section 3.1 of the Reference
P = Pressure = 1,000 psi unit load Di= Inner Diameter at end of model = 9.834 in Do = Outer Diameter at end of model = 10.815 in Therefore, the membrane stress is 4,774 psi. The calculated value is given a negative sign in order for it to exert tension on the piping end of the model. The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, input file VYCSNGEOMINP].
[3]calculation.
The ANSYS input file VY 16Q_P.INP, as obtained from Appendix A of Reference [5], contains the pressure loading. Figure 1 shows the applied 1,000 psi internal pressure distribution. At the vessel wall, a symmetric boundary condition is applied. At the piping end of the model, axial displacement is coupled to simulate the effect of the attached piping that is not modeled. Figure 2 and Figure 3 show the boundary conditions.
4.0 CALCULATIONS 4.1 Finite Element Unit Pressure Stress Analysis A uniform pressure of 1,000 psi was applied to the FEM along the inside surface of the CS nozzle and the RPV wall (Figure 1). A pressure load of 1,000 psi was used because it is easily scaled up or FileNo.: 0801038.302 Page 3 of 15 Revision:
1 F0306-O1RO Structural Integrity Associates, Inc.down to account for different pressures that occur during transients.
In addition, a membrane stress"cap load" was applied to the modeled end of the piping attached to the core spray nozzle safe end.This membrane stress was calculated as follows: p* Di2 cap -2 2 Do -Di where: P = Pressure = 1,000 psi unit load Di= Inner Diameter at end of model = 9.834 in Do = Outer Diameter at end of model = 10.815 in Therefore, the membrane stress is 4,774 psi. The calculated value is given a negative sign in order for it to exert tension on the piping end of the model. The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, input file VYCSNGEOMINP].
The ANSYS input file VY 16Q_P.INP, as obtained from Appendix A of Reference
[5], contains the pressure loading. Figure 1 shows the applied 1,000 psi internal pressure distribution.
At the vessel wall, a symmetric boundary condition is applied. At the piping end of the model, axial displacement is coupled to simulate the effect of the attached piping that is not modeled. Figure 2 and Figure 3 show the boundary conditions.
4.2 Thermal Transient Stress Analysis The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, file VYCSNGEOM.INP], and is used as input to the files in which the thermal transient and pressure stress analyses are performed.
4.2 Thermal Transient Stress Analysis The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, file VYCSNGEOM.INP], and is used as input to the files in which the thermal transient and pressure stress analyses are performed.
For the thermal transient ANSYS analyses, previously defined thernal transients
For the thermal transient ANSYS analyses, previously defined thernal transients [3, Table 2] are evaluated, applying heat transfer coefficients [3, Tables 4 through Table 18], as appropriate, based on the flow rates for each individual transient.
[3, Table 2] are evaluated, applying heat transfer coefficients
[3, Tables 4 through Table 18], as appropriate, based on the flow rates for each individual transient.
Each thermal transient is evaluated in ANSYS to determine the resulting temperature distributions.
Each thermal transient is evaluated in ANSYS to determine the resulting temperature distributions.
The thermal results are used as input for the stress analysis for each transient.
The thermal results are used as input for the stress analysis for each transient. The boundary conditions used for the pressure load case were also applied to the thermal stress cases. Figure 2 and Figure 3 show the application of these boundary conditions.
The boundary conditions used for the pressure load case were also applied to the thermal stress cases. Figure 2 and Figure 3 show the application of these boundary conditions.
All ANSYS input files for the thennal analyses, as listed below, are saved in the project computer files:
All ANSYS input files for the thennal analyses, as listed below, are saved in the project computer files: VY_CSNGEOM.INP:
VY_CSNGEOM.INP: Geometry and material properties VY_16QTRAAN2-T.INP, VY 16QTRAN2-S.INP: Transient 2, thermal and stress analyses VY_16QTRAN3-T.INP, VY 16QTRAN3-S.INP: Transient 3, thermal and stress analyses VTY_ 6QTRAN11-T.INP, VYI 16QTRAN11-S.INP: Transient 11, thermal and stress analyses FileNo.: 0801038.302                                                                             Page 4 of 15 Revision: I F0306-O1RO
Geometry and material properties VY_16QTRAAN2-T.INP, VY 16QTRAN2-S.INP:
 
Transient 2, thermal and stress analyses VY_16QTRAN3-T.INP, VY 16QTRAN3-S.INP:
StructuralIntegrity Associates, Inc.
Transient 3, thermal and stress analyses VTY_ 6QTRAN11-T.INP, VYI 16QTRAN11-S.INP:
VY_16QTRAN14-T.JNP, VY         16QTRAN14-S.INP: Transient 14, thermal and stress analyses VYý_]6QTRAN21-23-T.INP,       VY_ 6Q_TRAN21-23-S.INP: Transient 21-23, thermal and stress analyses VY_16QTRAN24-T.INP, VY         16QTRAN24-S.JNP: Transient 24, thermal and stress analyses VY_16QTRAN30-T.INP, VY         16QTRAN30-S.INP: Transient 30, thermal and stress analyses 4.3 Determining Critical Stress Paths From Section 4.0 of Reference [5], the critical location in the safe end was determined to be at Node 3719. This location was selected since it possessed the highest stress intensity during the worst case thermal transient.
Transient 11, thermal and stress analyses FileNo.: 0801038.302 Page 4 of 15 Revision:
Also from Section 4.0 of Reference [5], the critical stress location in the nozzle blend radius was chosen based upon the highest pressure stress (which is controlling in the nozzle blend radius). The pressure stress results showed the critical location in the nozzle blend radius to be at Node 2166.
I F0306-O1RO Structural Integrity Associates, Inc.VY_16QTRAN14-T.JNP, VY 16QTRAN14-S.INP:
Figure 4 shows the two critical stress paths that will be used to find the linearized stresses at the safe end and nozzle blend radius.
Transient 14, thermal and stress analyses VYý_]6QTRAN21-23-T.INP, VY_ 6Q_TRAN21-23-S.INP:
4.4 Stress Calculation Linearized stresses from Node 3719 (safe end inside surface) and Node 2166 (nozzle blend radius inside surface of base metal) are used for the fatigue usage analysis, as shown in Figure 4. For the nozzle blend radius location, the stresses used are for the base metal only; the cladding material is unselected prior to stress extraction.
Transient 21-23, thermal and stress analyses VY_16QTRAN24-T.INP, VY 16QTRAN24-S.JNP:
The pressure stress intensities for the safe end and blend radius paths were extracted using the ANSYS file VY_]6QP.INP. This produced one file, PRESSURE.lin, which contains results of the critical stress paths.
Transient 24, thermal and stress analyses VY_16QTRAN30-T.INP, VY 16QTRAN30-S.INP:
Table 1 shows the final pressure results for the safe end and blend radius. These results are slightly different from those reported in Table 14 of Reference [5] as a result of the revised material properties (i.e., temperature dependent material properties were used in the current evaluation vs. constant material properties in Reference [5]).
Transient 30, thermal and stress analyses 4.3 Determining Critical Stress Paths From Section 4.0 of Reference
FileNo.: 0801038.302                                                                               Page 5 of 15 Revision: 1 F0306-O1RO
[5], the critical location in the safe end was determined to be at Node 3719. This location was selected since it possessed the highest stress intensity during the worst case thermal transient.
 
Also from Section 4.0 of Reference
VStructural Integrity Associates, Inc.
[5], the critical stress location in the nozzle blend radius was chosen based upon the highest pressure stress (which is controlling in the nozzle blend radius). The pressure stress results showed the critical location in the nozzle blend radius to be at Node 2166.Figure 4 shows the two critical stress paths that will be used to find the linearized stresses at the safe end and nozzle blend radius.4.4 Stress Calculation Linearized stresses from Node 3719 (safe end inside surface) and Node 2166 (nozzle blend radius inside surface of base metal) are used for the fatigue usage analysis, as shown in Figure 4. For the nozzle blend radius location, the stresses used are for the base metal only; the cladding material is unselected prior to stress extraction.
Table 1: Pressure Results (1,000 psi)
The pressure stress intensities for the safe end and blend radius paths were extracted using the ANSYS file VY_]6QP.INP.
Membrane plus                   Total Stress Location                 Bending Stress                   Intensit Intensity                         (psi)
This produced one file, PRESSURE.
(psi)
lin, which contains results of the critical stress paths.Table 1 shows the final pressure results for the safe end and blend radius. These results are slightly different from those reported in Table 14 of Reference
Safe End                       12,030                         12,070 Blend Radius                     30,720                       36,150 Results were also extracted from the vessel portion of the model to verify the accuracy of the results obtained from the ANSYS model, and to check the results due to the use of the 2.0 multiplier on the vessel radius. These results are contained in the file PRESSURE.lin. The radius of the finite element model (FEM) was multiplied by a factor of 2.0 [3] to account for the fact that the vessel portion of the axisymmetric model is a sphere, but the true geometry is the intersection of two cylinders.
[5] as a result of the revised material properties (i.e., temperature dependent material properties were used in the current evaluation vs. constant material properties in Reference
The equation for the membrane hoop stress in a sphere is:
[5]).FileNo.: 0801038.302 Page 5 of 15 Revision:
(pressure)x (radius) 2 x thickness Considering a vessel base metal radius, R, of 105.906 inches increased by a factor of 2.0, a vessel base metal thickness, t, of 5.4375 inches, and an applied pressure, P, of 1,000 psi, the calculated stress for a sphere is PR/(2t) = 19,477 psi. This compares very well with the remote vessel wall membrane hoop stress from the ANSYS result file, PRESSURE.lin, of 18,960 psi. Thus, considering the peak total pressure stress of 36,150 psi reported above, the stress concentrating effect of the nozzle comer is 36,150/19,477 = 1.86. In other words, the peak nozzle comer stress is 1.86 times higher than nominal vessel wall stress for the axisymmetric model.
1 F0306-O1RO VStructural Integrity Associates, Inc.Table 1: Pressure Results (1,000 psi)Membrane plus Total Stress Location Bending Stress Intensit Intensity (psi)(psi)Safe End 12,030 12,070 Blend Radius 30,720 36,150 Results were also extracted from the vessel portion of the model to verify the accuracy of the results obtained from the ANSYS model, and to check the results due to the use of the 2.0 multiplier on the vessel radius. These results are contained in the file PRESSURE.
The equation for the membrane hoop stress in a cylinder is:
lin. The radius of the finite element model (FEM) was multiplied by a factor of 2.0 [3] to account for the fact that the vessel portion of the axisymmetric model is a sphere, but the true geometry is the intersection of two cylinders.
I
The equation for the membrane hoop stress in a sphere is: (pressure) x (radius)2 x thickness Considering a vessel base metal radius, R, of 105.906 inches increased by a factor of 2.0, a vessel base metal thickness, t, of 5.4375 inches, and an applied pressure, P, of 1,000 psi, the calculated stress for a sphere is PR/(2t) = 19,477 psi. This compares very well with the remote vessel wall membrane hoop stress from the ANSYS result file, PRESSURE.lin, of 18,960 psi. Thus, considering the peak total pressure stress of 36,150 psi reported above, the stress concentrating effect of the nozzle comer is 36,150/19,477  
((pressure) x (radius))
= 1.86. In other words, the peak nozzle comer stress is 1.86 times higher than nominal vessel wall stress for the axisymmetric model.The equation for the membrane hoop stress in a cylinder is: ((pressure) x (radius))thickness I Based on the previous dimensions, the calculated stress for a cylinder without the 2.0 factor is 19,477 psi. Increasing this by a factor of 1.86 yields an expected peak nozzle comer stress of 36,227 psi, which would be expected from a cylindrical geometry that is representative of the nozzle configuration.
thickness Based on the previous dimensions, the calculated stress for a cylinder without the 2.0 factor is 19,477 psi. Increasing this by a factor of 1.86 yields an expected peak nozzle comer stress of 36,227 psi, which would be expected from a cylindrical geometry that is representative of the nozzle configuration. Therefore, the result from the ANSYS file for the peak nozzle comer stress (36,150 psi) is close to the peak nozzle comer stress for a cylindrical geometry because of the use of the 2.0 File No.: 0801038.302                                                                             Page 6 of 15 Revision: 1 F0306-OIRO
Therefore, the result from the ANSYS file for the peak nozzle comer stress (36,150 psi) is close to the peak nozzle comer stress for a cylindrical geometry because of the use of the 2.0 File No.: 0801038.302 Page 6 of 15 Revision:
 
1 F0306-OIRO Structural Integrity Associates, Inc.multiplier.
StructuralIntegrity Associates, Inc.
This is consistent with SI's experience where a factor of two increase in radius is typical for representing the 3-D effect in an axisymmetric model.4.5 Piping Loads The piping loads per Reference
multiplier. This is consistent with SI's experience where a factor of two increase in radius is typical for representing the 3-D effect in an axisymmetric model.
[4] are as follows: F, = 2,500 lbs Mx= 264,000 in-lb Fy = 4,600 lbs My= 85,200 in-lb F, = 1,700 lbs Mz= 105,600 in-lb The point of loads application is at the intersection between the safe end-to-pipe weld [4, 61]Therefore, the safe end critical location is 0.303 inches and the nozzle blend radius is 30.817 inches from the load application point. (The nozzle blend radius location was measured from approximately the middle of the critical stress path for the blend radius and applied to the inside blend radius location along the critical stress path.) From general structural mechanics, the membrane plus bending stresses at the inside surface of a thick-walled cylinder are: cyzl = axial stress due to axial force = Fz/A cy, = axial stress due to bending moment = Mxy(ID/2)/I (z = Tzl 5"z2 ,re = shear stress due to torsion = Mz(ID/2)/J z = shear stress due to shear force = 2Fxy/A, where Fx, Fy, Fz, M,, My, and Mz are forces and moments at the pipe-to-safe end weld= moment about x axis translated by length z = -L = M, -Fy L MyL = moment about y axis translated by length z = -L = My + Fx L Mxy = resultant bending moment = (MxL 2 + MyL2)0.5 Fxy = resultant shear force = (Fx 2 + Fy2)0.5 ID, OD = inside and outside diameters A = area of cross section = (it/4)(OD 2 -ID 2)I = moment of inertia = (7/64)(OD 4 -ID 4)J = polar moment of inertia = (7/32)(0D 4 -ID 4)The piping load stress calculations for these locations are shown in Table 3.The piping loads tabulated in and pictorially shown in Reference
4.5 Piping Loads The piping loads per Reference [4] are as follows:
[4] were applied by CB&I at the safe end-to-pipe weld. Refer to Reference
F, = 2,500 lbs                   Mx= 264,000 in-lb Fy = 4,600 lbs                   My= 85,200 in-lb F, = 1,700 lbs                   Mz= 105,600 in-lb The point of loads application is at the intersection between the safe end-to-pipe weld [4, 61]
[6], page 9 of 13; CB&I RPV Stress Report, Section S7.FileNo.: 0801038.302 Page 7 of 15 Revision:
Therefore, the safe end critical location is 0.303 inches and the nozzle blend radius is 30.817 inches from the load application point. (The nozzle blend radius location was measured from approximately the middle of the critical stress path for the blend radius and applied to the inside blend radius location along the critical stress path.) From general structural mechanics, the membrane plus bending stresses at the inside surface of a thick-walled cylinder are:
1 F0306-01RO Structural Integrity Associates, Inc.5.0 RESULTS OF ANALYSIS A thermal transient analysis for each defined transient, as well as unit pressure stress and piping interface load analyses were performed for the CS nozzle at Vermont Yankee. All six components of the stress tensor were extracted from the ANSYS model at the two limiting path locations.
cyzl = axial stress due to axial force = Fz/A cy, = axial stress due to bending moment = Mxy(ID/2)/I (z =     Tzl 5"z2
Table 2 provides the unit pressure stress analysis results. The unit pressure load results are used to choose the location to analyze at the nozzle blend radius and will be scaled up or down based on applied pressures for the final fatigue analysis.
                    ,re = shear stress due to torsion     = Mz(ID/2)/J z = shear stress due to shear force = 2Fxy/A, where Fx, Fy, Fz, M,, My, and Mz are forces and moments at the pipe-to-safe end weld M* = moment about x axis translated by length z = -L = M, - Fy L MyL = moment about y axis translated by length z = -L = My + Fx L 2
Table 3 provides the piping stresses at the two critical locations.
Mxy = resultant bending moment = (MxL + MyL2)0.5 2
Table 4 shows an example of thermal stress results. The remaining thermal stress results are contained in the ANSYS output files, listed below, which are saved in the project computer files: PRESSURE.
Fxy = resultant shear force = (Fx + Fy2)0.5 ID, OD = inside and outside diameters             2 2
lin: Unit pressure stress analysis results VY_16QTRAN2-S.
A = area of cross section = (it/4)(OD - ID )
lin: Transient 2, thermal stress analysis results VY_ 6QTRAN3-S.
I = moment of inertia = (7/64)(OD 4 - ID 4)
lin: Transient 3, thermal stress analysis results VY_16QTRANll-S.lin:
J = polar moment of inertia = (7/32)(0D 4 - ID4)
Transient 11, thermal stress analysis results VY_16QTRAN14-S.lin:
The piping load stress calculations for these locations are shown in Table 3.
Transient 14, thernal stress analysis results VY_16QTRAN21-23-S.
The piping loads tabulated in and pictorially shown in Reference [4] were applied by CB&I at the safe end-to-pipe weld. Refer to Reference [6], page 9 of 13; CB&I RPV Stress Report, Section S7.
lih: Transient 21-23, thermal stress analysis results VY_16QTRAN24-S.
FileNo.: 0801038.302                                                                                             Page 7 of 15 Revision: 1 F0306-01RO
lin: Transient 24, thermal stress analysis results VY_]6Q TRAN3 0-S. lin: Transient 30, thermal stress analysis results A fatigue calculation using the methodology of Subarticle NB-3200 of Section III of the ASME Code [2] and an environmental fatigue usage analysis will be performed in a separate calculation package using the stress results from this calculation.
 
The results of this calculation are used in a subsequent SIA Calculation No. 0801038.303, "Fatigue Analysis of Core Spray Nozzle."  
StructuralIntegrityAssociates, Inc.
5.0     RESULTS OF ANALYSIS A thermal transient analysis for each defined transient, as well as unit pressure stress and piping interface load analyses were performed for the CS nozzle at Vermont Yankee. All six components of the stress tensor were extracted from the ANSYS model at the two limiting path locations. Table 2 provides the unit pressure stress analysis results. The unit pressure load results are used to choose the location to analyze at the nozzle blend radius and will be scaled up or down based on applied pressures for the final fatigue analysis. Table 3 provides the piping stresses at the two critical locations. Table 4 shows an example of thermal stress results. The remaining thermal stress results are contained in the ANSYS output files, listed below, which are saved in the project computer files:
PRESSURE.lin: Unit pressure stress analysis results VY_16QTRAN2-S. lin: Transient 2, thermal stress analysis results VY_ 6QTRAN3-S. lin: Transient 3, thermal stress analysis results VY_16QTRANll-S.lin: Transient 11, thermal stress analysis results VY_16QTRAN14-S.lin: Transient 14, thernal stress analysis results VY_16QTRAN21-23-S. lih: Transient 21-23, thermal stress analysis results VY_16QTRAN24-S. lin: Transient 24, thermal stress analysis results VY_]6Q TRAN3 0-S. lin: Transient 30, thermal stress analysis results A fatigue calculation using the methodology of Subarticle NB-3200 of Section III of the ASME Code [2] and an environmental fatigue usage analysis will be performed in a separate calculation package using the stress results from this calculation.
The results of this calculation are used in a subsequent SIA Calculation No. 0801038.303, "Fatigue Analysis of Core Spray Nozzle."
 
==6.0    REFERENCES==
: 1. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.
: 2. ASME Boiler and Pressure Vessel Code, Section III, Subsection-NB, 1998 Edition with 2000 Addenda.
: 3. SI Calculation No. 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle."
: 4. VY Drawing 5920-0024, Revision 11, Sht. No. 7, "Reactor Vessel," (GE Drawing No.
919D294), SI File No. VY-05Q-241.
: 5. SI Calculation No. VY-16Q-309, Revision 1, "Core Spray Nozzle Green's Functions."
: 6. Entergy Design Input Record (DIR), Rev. 1, EC No. 1773, Rev. 0, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY- 16Q-209.
FileNo.: 0801038.302                                                                                Page 8 of 15 Revision: 1 F0306-01RO
 
StructuralIntegrity Associates, Inc.
Table 2: Stresses Under Unit Pressure Load, psi Membrane plus Bending                        Total Node  S      SY      Sz      Sxy  Syz Sxz  SX    S      Sz      Sxy    Syz Sxz SafeEnd    3719 -1011  4829  11010  -104.8  0  0  -1011  4912  11050  -85.31    0  0 Blend Radius 2166 -1052  1657  25960    4886  0  0  -1052  1720  35050  348.9      0  0 FileNo.: 0801038.302                                                                    Page 9 of 15 Revision: 1 F0306-01RO
 
StructuralIntegrity Associates, Inc.
Table 3: Membrane Plus Bending Stresses Due to Piping Loads Safe End        Blend Radius Fx, kip          2.5            2.5 Fy, kip          4.6            4.6 F,, kip          1.7          1.7 Mx, kip-in          264          264 My, kip-in          85.2          85.2 M,, kip-in        105.6        105.6 L, in        0.30          30.82 MxL, kip-in      262.61        122.24 MyL, kip-in        85.96        162.24 MxY, kip-in      276.32        203.14 Fy,, kip-in        5.24          5.24 OD, in          10.82        24.25 ID,in          9.834        12.125 A, in2          15.91        346.40 I, in4        212.46      15914.32 J, in4        424.93      31828.64 a.,, ksi        0.107        0.005 az2, ksi        6.395        0.077 oz,  ksi        6.502        0.082 "ro, ksi        1.222        0.020 cz, ksi        0.658        0.030 Note: The axial and shear stresses are expressed in a local coordinate system with r radial (X in ANSYS coordinates), 0 circumferential (Z in ANSYS coordinates), and Z axial (Y in ANSYS coordinates) components with respect to the nozzle centerline.
File No.: 0801038.302                                                                                          Page 10 of 15 Revision: 1 F0306-01RO
 
StructuralIntegrity Associates, Inc.
Table 4: Example Thermal Stress Result Output, psi Membrane Plus Bending                          Total Transient NodeI I Time (s) I.Sx            Sy        Sz    Sxy  Syz Sxz'  Sx    Sy    Sz      Sxy  Syz  Sxz 0        48      288        696    -50    0  0    48          641      -86        0 10.002      49      280        689    -50    0  0    49    -11    630      -86        0 123.23      52      197        644    -53    0  0    52  -131    561      -89        0 1716.1    124      467        1587  -123    0  0    124  -293  1413    -212        0 6984.8    380      1918      5199  -385    0  0  380    -358  4733    -663        0 7946.2    430      2206      5907  -436    0  0  430    -365  5384    -752        0 8919      482      2506      6638  -489    0  0  482    -371  6056    -843        0 16055      845      4684      11830  -857    0  0    845  -352  10830    -1487        0 16164    -849      4707      11880  -861    0  0    849  -352  10880    -1494        0 3719 16304      850      4831      12000  -864    0  0    850  -219  11020    -1500        0 19448      851      5001      12110  -870    0  0    851    -45  11140    -1506        0 20622      851      5002      12110  -870    0  0    851    -44  11140    -1506        0 29155      851      5002      12110  -870    0  0    851    -44  11140    -1506        0 32155      851      5002      12110  -870    0  0    851    -44  11140    -1506        0 40155      851      5002      12110  -870    0  0    851    -44  11140    -1506        0 50155      851      5002      12110  -870    0  0    851    -44  11140    -1506        0 65155      851      5002      12110  -870    0  0    851    -44  11140    -1506        0 66165      851      5002      12110  -870    0  0    851    -44  11140    -1506        0 3
0        86      -140        1025    44        0    87  -1084  -628      -68        0 10.002      87      -141        1030    44        0    109  -1242  -955      -70        0 123.23      109    -210        1224    60        0    310  -3331  -4776    -184        0 1716.1    310    -1469      2676    359        0    794  -9114  -9547    -537        0 6984.8    794    -2777      8114    775        0    882 -10220 -10520    -607        0 7946.2    882    -3032      8912    812        0    973 -11350 -11470    -678        0 8919      973    -3298      9762    859        0  1553 -18930 -18300    -1177        0 16055    1553    -5119      14660  1049        0  1562 -19040 -18390    -1184        0 16164    1562    -5143      14730  1051        0  1545 -18980 -18070    -1190        0 2166 16304    1545    -5079      14620  1032        0  1433 -18220 -14130    -1169        0
                          .19448    1433    -3608      14270  632        0  1422 -18180 -13900    -1169        0 20622      1422    -3508      14050  566        0  1409 -18140 -13810,  -1173        0 29155      1409    -3451      13540  461        0  1409 -18140 -13810    -1173        0 32155      1409    -3452      13520  459        0  1409 -18140 -13810    -1173        0 40155      1409    -3452      13510  458        0  1409 -18140 -13810    -1173        0 50155      1409    -3452      13510  458        0  1409 -18140 -13810    -1173        0 65155      1409    -3452      13510  458        0  1409 -18140 -13810    -1173        0 66165      1409    -3452      13510  458        0  1409 -18140 -13810    -1173        0 Note: Not all time steps are listed in this table.
File No.: 0801038.302                                                                                    Page 11 of 15 Revision: 1 F0306-01RO
 
V      StructuralIntegrityAssociates, Inc.
Figure 1. Core Spray Nozzle Internal Pressure Distribution File No.: 0801038.302                                                            Page 12 of 15 Revision: 1 F0306-O1RO
 
StructuralIntearityAssociates, Inc.
inc.
Integrity Associates,
    *Structurai Core Spray Nozzle Finite Element Model Figure 2. Core Spray Nozzle Pressure Cap Load & Boundary Condition File No.: 0801038.302                                                              Page 13 of 15 Revision: 1 F0306-01RO
 
StructuralIntegrity Associates, Inc.
Core  Spray Nozzle Finite  Element Model Figure 3. Core Spray Nozzle Vessel Wall Boundary Condition FileNo.: 0801038.302                                                            Page 14 of 15 Revision: 1 F0306-O1RO
 
V    StructuralIntegrity Associates, Inc.
V~~~~rd~N pi3t l~~l dpa
                              -0:1 NodE2166 C-r $pray :hzerirnre zl--es -o1q, Figure 4. Limiting Stress Paths FileNo.: 0801038.302                                                                  Page 15 of 15 Revision: 1 F0306-01RO
 
J V StructuralIntegrityAssociates, Inc.                    File No.: 0801038.303 Project No.: 0801038, CALCULATION PACKAGE                              ,Quality Program Z Nuclear  L!  Commercial PROJECT NAME:
VY Confirmatory Analysis for the CS and RO Nozzles CONTRACT NO.:
10163217 Amendment 5 CLIENT:                                            PLANT:
Entergy Nuclear Operations, Inc                  Vermont Yankee Nuclear Power Station CALCULATION TITLE:
Fatigue Analysis of Reactor Core Spray Nozzle, Document      Affected                                      Project Manager          Preparer(s) &
Revision        Pages        Revision Description              Approval                Checker(s)
Signature & Date        Signatures & Date 0            1 - 18            Initial issue.
Gary L. Stevens          Tyler Novotny Computer Files.                                      01/06/09                  01/06/09 W. F. Weitze 01/06/09 1      1-3, 5-8, 11-12,  Revised per summary                          .. Preparer:
17-18      contained in Section 1.1.            /            -
Changes are marked with        Gary L. Stevens Computer Files.    "revision bars" in right-hand margin.                03/09/09            Tyler D. Novotny 03/09/09 Checker:
Tim D. Gilman 03/09/09 Page 1 of 18 F0306-O1RO
 
VStructural Integrity Associates, Inc.
Table of Contents 1.0  O B JEC T IVE .................................................................................................................................                3 1.1    Changes Made in Revision 1 of this Calculation ...........................                                                                              3 2.0 M E TH O D O L O G Y ...........................................................................................                ...        ................... 3 3.0 D E SIG N IN P U TS .........................................................................................................................                    3 3.1    Stress C alculation ..........................................................................................................                          3 3.2    Fatigue Usage Analysis, General ..................................................................................                                      4 3.3    Event Cycles, V ESLFA T ...............................................................................................                                  4 3.4    M aterial Properties, VESLFA T .....................................................................................                                    5 3.5    Stress Indices .............................................................................................................                            5 4.0 C A L C U L A TION S .........................................................................................................................                    6 5.0  RESULTS OF ANALYSIS .............................................                                                                                              7
 
==6.0  CONCLUSION==
S AND DISCUSSIONS ...............................................................................                                                    7 7.0    RE FEREN CE S .............................................................              ...............................................................      8 List of Tables Table    1: Safe End Load Sets as Input to VESLFAT .......................................................................                                            9 Table  2: Nozzle Blend Radius Load Sets as Input to VESLFAT .......................................................                                                10 Table  3: Temperature-Dependent Material Properties for VESLFAT ....................                                                                                11 Table  4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves ....................                                                                            12 Table  5: Pressure and Attached Piping Unit LoadCase Stress Components .................................                                                            13 Table  6: Fatigue Usage Calculation for the Safe End (Inconel) .......                                                  .................                          13 Table  7: Fatigue Usage Calculation for the Safe End (Stainless Steel) ..........................................                                                  14 Table  8: Fatigue Usage Calculation for the Nozzle Blend Radius                                                        .......................                    15 Table  9: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location ........................                                                              16 Table  10: Linearized Stress Files Compiled for VY-StressResults.xls ......................                                                                        18 File No.: 0801038.303                                                                                                                                            Page 2 of 18 Revision: 1 F0306-01RO


==6.0 REFERENCES==
VStructural Integrity Associates, Inc.
: 1. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.2. ASME Boiler and Pressure Vessel Code, Section III, Subsection-NB, 1998 Edition with 2000 Addenda.3. SI Calculation No. 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle." 4. VY Drawing 5920-0024, Revision 11, Sht. No. 7, "Reactor Vessel," (GE Drawing No.919D294), SI File No. VY-05Q-241.
1.0      OBJECTIVE The objective of this calculation package is to perform an ASME Code, Section III fatigue usage evaluation and a plant-specific evaluation of reactor water environmental effects for the reactor pressure vessel (RPV) core spray (CS) nozzle at the Vermont Yankee Nuclear Power Station.
: 5. SI Calculation No. VY-16Q-309, Revision 1, "Core Spray Nozzle Green's Functions." 6. Entergy Design Input Record (DIR), Rev. 1, EC No. 1773, Rev. 0, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY- 16Q-209.FileNo.: 0801038.302 Page 8 of 15 Revision:
1.1    Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:
1 F0306-01RO Structural Integrity Associates, Inc.Table 2: Stresses Under Unit Pressure Load, psi Membrane plus Bending Total Node S SY Sz Sxy Syz Sxz SX S Sz Sxy Syz Sxz SafeEnd 3719 -1011 4829 11010 -104.8 0 0 -1011 4912 11050 -85.31 0 0 Blend Radius 2166 -1052 1657 25960 4886 0 0 -1052 1720 35050 348.9 0 0 FileNo.: 0801038.302 Revision:
: a. Changed Reference [1] to reflect revision of that document.
1 Page 9 of 15 F0306-01RO Structural Integrity Associates, Inc.Table 3: Membrane Plus Bending Stresses Due to Piping Loads Safe End Blend Radius Fx, kip 2.5 2.5 Fy, kip 4.6 4.6 F,, kip 1.7 1.7 Mx, kip-in 264 264 My, kip-in 85.2 85.2 M,, kip-in 105.6 105.6 L, in 0.30 30.82 MxL, kip-in 262.61 122.24 MyL, kip-in 85.96 162.24 MxY, kip-in 276.32 203.14 Fy,, kip-in 5.24 5.24 OD, in 10.82 24.25 ID, in 9.834 12.125 A, in 2  15.91 346.40 I, in 4 212.46 15914.32 J, in 4  424.93 31828.64 a.,, ksi 0.107 0.005 az2, ksi 6.395 0.077 oz, ksi 6.502 0.082"ro, ksi 1.222 0.020 cz, ksi 0.658 0.030 Note: The axial and shear stresses are expressed in a local coordinate system with r radial (X in ANSYS coordinates), 0 circumferential (Z in ANSYS coordinates), and Z axial (Y in ANSYS coordinates) components with respect to the nozzle centerline.
: b. All other changes marked throughout this calculation are editorial changes made to the text of the calculation package.
File No.: 0801038.302 Revision:
2.0      METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package
1 Page 10 of 15 F0306-01RO Structural Integrity Associates, Inc.Table 4: Example Thermal Stress Result Output, psi Transient Node Time Membrane Plus Bending Total I I (s) I.Sx Sy Sz Sxy Syz Sxz' Sx Sy Sz Sxy Syz Sxz 3719 0 10.002 123.23 1716.1 6984.8 7946.2 8919 16055 16164 16304 19448 20622 29155 32155 40155 50155 65155 66165 48 49 52 124 380 430 482 845-849 850 851 851 851 851 851 851 851 851 288 280 197 467 1918 2206 2506 4684 4707 4831 5001 5002 5002 5002 5002 5002 5002 5002 696 689 644 1587 5199 5907 6638 11830 11880 12000 12110 12110 12110 12110 12110 12110 12110 12110-50-50-53-123-385-436-489-857-861-864-870-870-870-870-870-870-870-870 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 49 52 124 380 430 482 845 849 850 851 851 851 851 851 851 851 851-11-131-293-358-365-371-352-352-219-45-44-44-44-44-44-44-44 641 -86 630 -86 561 -89 1413 -212 4733 -663 5384 -752 6056 -843 10830 -1487 10880 -1494 11020 -1500 11140 -1506 11140 -1506 11140 -1506 11140 -1506 11140 -1506 11140 -1506 11140 -1506 11140 -1506 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 2166 0 10.002 123.23 1716.1 6984.8 7946.2 8919 16055 16164 16304.19448 20622 29155 32155 40155 50155 65155 66165 86 -140 87 -141 109 -210 310 -1469 794 -2777 882 -3032 973 -3298 1553 -5119 1562 -5143 1545 -5079 1433 -3608 1422 -3508 1409 -3451 1409 -3452 1409 -3452 1409 -3452 1409 -3452 1409 -3452 1025 1030 1224 2676 8114 8912 9762 14660 14730 14620 14270 14050 13540 13520 13510 13510 13510 13510 44 44 60 359 775 812 859 1049 1051 1032 632 566 461 459 458 458 458 458 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 87 109 310 794 882 973 1553 -18930 1562 -19040 1545 -18980 1433 -18220 1422 -18180 1409 -18140 1409 -18140 1409 -18140 1409 -18140 1409 -18140 1409 -18140 1409 -18140-1084-1242-3331-9114-10220-11350-628 955 4776 -184-9547 -537-10520 -607-11470 -678-18300 -1177-18390 -1184-18070 -1190-14130 -1169-13900 -1169-13810, -1173-13810 -1173-13810 -1173-13810 -1173-13810 -1173-13810 -1173-13810 -1173 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Note: Not all time steps are listed in this table.File No.: 0801038.302 Revision:
[2]. Based on that methodology, thermal stresses, pressure stresses, and attached piping load stresses were developed in the Reference [1] calculation for use in a fatigue calculation. The thermal stresses are added to pressure stresses and attached piping load stresses 1 . Both the pressure and piping' load stresses are scaled based on the magnitudes of the pressure and nozzle temperature during each transient. All six components of the stress tensor from the stress results are used in the fatigue calculation.
1 Page 11 of 15 F0306-01RO V Structural Integrity Associates, Inc.Figure 1. Core Spray Nozzle Internal Pressure Distribution File No.: 0801038.302 Revision:
The fatigue calculation is performed for both of the limiting safe end and nozzle blend radius locations, as determined in the Reference [1] calculation, and uses the methodology of Subarticle NB-3200 of Section III of the ASME Code [3]. An environmental fatigue usage analysis is also performed in this calculation applying the methodology described in Reference [6].
1 Page 12 of 15 F0306-O1RO Structural Intearity Associates, Inc.Structurai Integrity Associates, inc.Core Spray Nozzle Finite Element Model Figure 2. Core Spray Nozzle Pressure Cap Load & Boundary Condition File No.: 0801038.302 Revision:
3.0      DESIGN INPUTS 3.1 Stress Calculation Linearized stress components at Node 3719 (limiting safe end path at inside surface) and Node 2166 (limiting nozzle blend radius path at inside surface) are used for the fatigue usage calculation, as shown in Figure 4 of Reference [1]. For the nozzle blend radius location, the stresses used in the evaluation are for the base metal only; that is, the cladding material is unselected prior to stress extraction. The stress components from the thermal stress analyses are combined with stress components due to pressure and piping loads. The linearized thermal stress components for each Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 70'F and the full values are reached at a reactor design temperature of 575F [2, Assumption 3.1.7]. In addition, design seismic and deadweight loads are also included and scaled in combination with the thermal loads for each transient. This combination, coupled with assigning the stress due to these loads the same sign as the thermal stress, is considered to be a very conservative treatment of the loads overall in that deadweight and design seismic loads are considered and scaled for every transient.
1 Page 13 of 15 F0306-01RO Structural Integrity Associates, Inc.Core Spray Nozzle Finite Element Model Figure 3. Core Spray Nozzle Vessel Wall Boundary Condition FileNo.: 0801038.302 Revision:
File No.: 0801038.303                                                                                                    Page 3 of 18 Revision: 1 F0306-OIRO
1 Page 14 of 15 F0306-O1RO V Structural Integrity Associates, Inc.V~~~~rd~N dpa -0:1 pi3t l~~l NodE 2166 C-r $pray :hzerirnre zl--es -o1q, Figure 4. Limiting Stress Paths FileNo.: 0801038.302 Revision:
 
1 Page 15 of 15 F0306-01RO J V Structural Integrity Associates, Inc. File No.: 0801038.303 Project No.: 0801038, CALCULATION PACKAGE ,Quality Program Z Nuclear L! Commercial PROJECT NAME: VY Confirmatory Analysis for the CS and RO Nozzles CONTRACT NO.: 10163217 Amendment 5 CLIENT: PLANT: Entergy Nuclear Operations, Inc Vermont Yankee Nuclear Power Station CALCULATION TITLE: Fatigue Analysis of Reactor Core Spray Nozzle, Document Affected Project Manager Preparer(s)
StructuralIntegrity Associates, Inc.
&Revision Pages Revision Description Approval Checker(s)
transient are taken from the relevant output files associated with the Reference [1] calculation (a sample of which was provided in Table 4 of Reference [1]). The unit pressure stress component results are taken from Table 2 of Reference [1]. Piping load stress components are taken from Table 3 of the Reference [I] calculation.
Signature
3.2 Fatigue Usage Analysis, General Structural Integrity's VESLFAT program [4] is used to perform the fatigue usage calculation in accordance with the fatigue usage portion of ASME Code Subarticle NB-3200 [3]. VESLFAT performs the analysis required by NB-3222.4(e) [3] for Service Levels A and B conditions defined by the user. The VESLFAT program computes the primary-plus-secondary and total stress ranges for all events and performs a correction for elastic-plastic analysis, if necessary.
& Date Signatures
The program computes the stress intensity range based on the stress component ranges for all event pairs [3, NB-3216.2]. The program evaluates the stress ranges for primary-plus-secondary and primary-plus-secondary-plus-peak stresses based on all six components of stress (3 normal and 3 shear stresses). If the primary-plus-secondary stress intensity range is greater than 3 Sm, the total stress range must be increased by the simplified elastic-plastic strain correction factor Ke, as described in NB-3228.5 [3]. The design stress intensity, Sm, is specified as a function of temperature. The input maximum temperature for both states of a load set pair is used to determine the temperature that Sm is determined from the user-defined values.
& Date 0 1 -18 Initial issue.Gary L. Stevens Tyler Novotny Computer Files. 01/06/09 01/06/09 W. F. Weitze 01/06/09 1 1-3, 5-8, 11-12, Revised per summary ..Preparer: 17-18 contained in Section 1.1. / -Changes are marked with Gary L. Stevens Computer Files. "revision bars" in right-hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker: Tim D. Gilman 03/09/09 Page 1 of 18 F0306-O1RO VStructural Integrity Associates, Inc.Table of Contents 1.0 O B JE C T IV E .................................................................................................................................
When more than one stress set is defined for either of the event pair loadings, the stress differences are determined for all of the potential stress pairs, saving the maximum for the event pair, based on the pair producing the largest alternating total stress intensity (Salt), including any effects of Ke. The principal stresses for the stress ranges are determined by solving for the roots of the following cubic equation2:
3 1.1 Changes Made in Revision 1 of this Calculation
S3 _ (aix "+ aiy +k (iz)S2 -+- ((x (yy + a(y (iz + (iz U, - Sxyz -x2_    2_-X yz2 )S
...........................
                        - ((Fxa (y Uz + 2rxy Txz T"yz -   Uz Cxy    -2 (y Txz -_ax Tyz    )  0 The stress intensities for the event pairs are reordered in decreasing order of Salt, including a correction for the ratio of modulus of elasticity (E) from the fatigue curve divided by E from the material evaluated at the maximum event temperature. This allows a fatigue table to be created to eliminate the number of cycles available for each of the transient events. This fatigue table is based on a worst-case progressive pairing of events in order of the most severe alternating stress to the least severe, allowing determination of a bounding fatigue usage per NB-3222.4(e) [3]. For each load set pair in the fatigue table, the allowable number of cycles is determined based on Salt.
3 2.0 M E TH O D O L O G Y ...........................................................................................
3.3       Event Cycles, VESLFAT For the Vermont Yankee CS nozzle analysis, transients that consist of combined stress ramps are split so that each successive ramp is treated separately. Therefore, there are 25 load sets based on the combined stress changes for the safe end, and 27 load sets based on the combined stress changes 2 Note that a., a,, a,, etc. are used synonymously with S,, S,,, S., etc., in this calculation.
... ...................
File No.: 0801038.303                                                                                      Page 4 of 18 Revision: 1 F0306-OIRO
3 3.0 D E SIG N IN P U T S .........................................................................................................................
3 3.1 Stress C alculation
..........................................................................................................
3 3.2 Fatigue U sage A nalysis, General ..................................................................................
4 3.3 Event Cycles, V ESLFA T ...............................................................................................
4 3.4 M aterial Properties, VESLFA T .....................................................................................
5 3.5 Stress Indices .............................................................................................................
5 4.0 C A L C U L A T IO N S .........................................................................................................................
6 5.0 RESULTS OF ANALYSIS .............................................
7


==6.0 CONCLUSION==
V    StructuralIntegrityAssociates, Inc.
S AND DISCUSSIONS
for the nozzle blend radius location. The reason the number of load sets are not equal for each path is because the time history stress results of those paths differ. Tables 1 and 2 show the load sets applicable to plant operation, with cycle counts per Table 2 of Reference [2], used as input to VESLFAT for the safe end and nozzle blend radius locations, respectively. The cycle counts of Reference [2] consider 60 years of operation; see Reference [8] for the numbers of cycles. The data from Table I is entered into the VESLFAT input files VY-VFA T-1I. CYC (safe end-Inconel) and VY-VFAT2-1I.CYC (safe end-Stainless Steel), and the data from Table 2 is entered into the. file VY-VFA T-21.CYC (nozzle blend radius).
...............................................................................
3.4     Material Properties, VESLFAT Material properties are entered in VESLFAT input files VY-VFAT-]1.FDT (safe end-Inconel), VY-VY-VFAT2-1LFDT (safe end-Stainless Steel) and VY-VFAT-2I.FDT (nozzle blend radius). Table 3 lists the temperature-dependent material properties used in the analysis [5]. Table 4 lists the fatigue curve for the nozzle and safe end materials [3, Appendix I, Table 1-9.1 and Figure 1-9.1 (UTS < 80.0 ksi) for the nozzle blend radius, and Tables 1-9.1 and 1-9.2.2 (Curve C) and Figures 1-9.2.1 and 1-9.2.2 for both safe end locations]. Curve C is selected because it is the most conservative curve among the three extended curves for austenitic steel. VESLFAT automatically scales the stresses by the ratio of E on the fatigue curve to E in the analysis, for purposes of determining allowable numbers of cycles, as required by the ASME Code.
7 7.0 R E FE R E N C E S .............................................................
Other material properties are input as follows:
...............................................................
m 1.7, n = 0.3, parameters used to calculate Ke for the safe end location (both materials) [3, Table NB-3228.5(b)-1]
8 List of Tables Table 1: Safe End Load Sets as Input to VESLFAT .......................................................................
9 Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT .......................................................
10 Table 3: Temperature-Dependent Material Properties for VESLFAT ....................
11 Table 4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves ....................
12 Table 5: Pressure and Attached Piping Unit LoadCase Stress Components
.................................
13 Table 6: Fatigue Usage Calculation for the Safe End (Inconel)
....... .................
13 Table 7: Fatigue Usage Calculation for the Safe End (Stainless Steel) ..........................................
14 Table 8: Fatigue Usage Calculation for the Nozzle Blend Radius .......................
15 Table 9: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location ........................
16 Table 10: Linearized Stress Files Compiled for VY-StressResults.xls
......................
18 File No.: 0801038.303 Page 2 of 18 Revision:
1 F0306-01RO VStructural Integrity Associates, Inc.1.0 OBJECTIVE The objective of this calculation package is to perform an ASME Code, Section III fatigue usage evaluation and a plant-specific evaluation of reactor water environmental effects for the reactor pressure vessel (RPV) core spray (CS) nozzle at the Vermont Yankee Nuclear Power Station.1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:
: a. Changed Reference
[1] to reflect revision of that document.b. All other changes marked throughout this calculation are editorial changes made to the text of the calculation package.2.0 METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package[2]. Based on that methodology, thermal stresses, pressure stresses, and attached piping load stresses were developed in the Reference
[1] calculation for use in a fatigue calculation.
The thermal stresses are added to pressure stresses and attached piping load stresses 1.Both the pressure and piping' load stresses are scaled based on the magnitudes of the pressure and nozzle temperature during each transient.
All six components of the stress tensor from the stress results are used in the fatigue calculation.
The fatigue calculation is performed for both of the limiting safe end and nozzle blend radius locations, as determined in the Reference
[1] calculation, and uses the methodology of Subarticle NB-3200 of Section III of the ASME Code [3]. An environmental fatigue usage analysis is also performed in this calculation applying the methodology described in Reference
[6].3.0 DESIGN INPUTS 3.1 Stress Calculation Linearized stress components at Node 3719 (limiting safe end path at inside surface) and Node 2166 (limiting nozzle blend radius path at inside surface) are used for the fatigue usage calculation, as shown in Figure 4 of Reference
[1]. For the nozzle blend radius location, the stresses used in the evaluation are for the base metal only; that is, the cladding material is unselected prior to stress extraction.
The stress components from the thermal stress analyses are combined with stress components due to pressure and piping loads. The linearized thermal stress components for each Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 70'F and the full values are reached at a reactor design temperature of 575F [2, Assumption 3.1.7]. In addition, design seismic and deadweight loads are also included and scaled in combination with the thermal loads for each transient.
This combination, coupled with assigning the stress due to these loads the same sign as the thermal stress, is considered to be a very conservative treatment of the loads overall in that deadweight and design seismic loads are considered and scaled for every transient.
File No.: 0801038.303 Page 3 of 18 Revision:
1 F0306-OIRO Structural Integrity Associates, Inc.transient are taken from the relevant output files associated with the Reference
[1] calculation (a sample of which was provided in Table 4 of Reference
[1]). The unit pressure stress component results are taken from Table 2 of Reference
[1]. Piping load stress components are taken from Table 3 of the Reference
[I] calculation.
3.2 Fatigue Usage Analysis, General Structural Integrity's VESLFAT program [4] is used to perform the fatigue usage calculation in accordance with the fatigue usage portion of ASME Code Subarticle NB-3200 [3]. VESLFAT performs the analysis required by NB-3222.4(e)
[3] for Service Levels A and B conditions defined by the user. The VESLFAT program computes the primary-plus-secondary and total stress ranges for all events and performs a correction for elastic-plastic analysis, if necessary.
The program computes the stress intensity range based on the stress component ranges for all event pairs [3, NB-3216.2].
The program evaluates the stress ranges for primary-plus-secondary and primary-plus-secondary-plus-peak stresses based on all six components of stress (3 normal and 3 shear stresses).
If the primary-plus-secondary stress intensity range is greater than 3 Sm, the total stress range must be increased by the simplified elastic-plastic strain correction factor Ke, as described in NB-3228.5
[3]. The design stress intensity, Sm, is specified as a function of temperature.
The input maximum temperature for both states of a load set pair is used to determine the temperature that Sm is determined from the user-defined values.When more than one stress set is defined for either of the event pair loadings, the stress differences are determined for all of the potential stress pairs, saving the maximum for the event pair, based on the pair producing the largest alternating total stress intensity (Salt), including any effects of Ke. The principal stresses for the stress ranges are determined by solving for the roots of the following cubic equation2:
S3 _ (aix "+ aiy +k (iz)S2 -+- ((x (y y + a (y (iz + (iz U, -Sxyz -x2 _ -X 2 _ yz2 )S-((Fxa (y Uz + 2 rxy Txz T"yz -Uz Cxy -2 (y Txz -_ax Tyz ) 0 The stress intensities for the event pairs are reordered in decreasing order of Salt, including a correction for the ratio of modulus of elasticity (E) from the fatigue curve divided by E from the material evaluated at the maximum event temperature.
This allows a fatigue table to be created to eliminate the number of cycles available for each of the transient events. This fatigue table is based on a worst-case progressive pairing of events in order of the most severe alternating stress to the least severe, allowing determination of a bounding fatigue usage per NB-3222.4(e)
[3]. For each load set pair in the fatigue table, the allowable number of cycles is determined based on Salt.3.3 Event Cycles, VESLFAT For the Vermont Yankee CS nozzle analysis, transients that consist of combined stress ramps are split so that each successive ramp is treated separately.
Therefore, there are 25 load sets based on the combined stress changes for the safe end, and 27 load sets based on the combined stress changes 2 Note that a., a,, a,, etc. are used synonymously with S,, S,,, S., etc., in this calculation.
File No.: 0801038.303 Page 4 of 18 Revision:
1 F0306-OIRO V Structural Integrity Associates, Inc.for the nozzle blend radius location.
The reason the number of load sets are not equal for each path is because the time history stress results of those paths differ. Tables 1 and 2 show the load sets applicable to plant operation, with cycle counts per Table 2 of Reference
[2], used as input to VESLFAT for the safe end and nozzle blend radius locations, respectively.
The cycle counts of Reference
[2] consider 60 years of operation; see Reference
[8] for the numbers of cycles. The data from Table I is entered into the VESLFAT input files VY-VFA T-1I. CYC (safe end-Inconel) and VY-VFAT2-1I.
CYC (safe end-Stainless Steel), and the data from Table 2 is entered into the. file VY-VFA T-21. CYC (nozzle blend radius).3.4 Material Properties, VESLFAT Material properties are entered in VESLFAT input files VY-VFAT-]1.FDT (safe end-Inconel), VY-VY-VFAT2-1LFDT (safe end-Stainless Steel) and VY-VFAT-2I.FDT (nozzle blend radius). Table 3 lists the temperature-dependent material properties used in the analysis [5]. Table 4 lists the fatigue curve for the nozzle and safe end materials
[3, Appendix I, Table 1-9.1 and Figure 1-9.1 (UTS < 80.0 ksi) for the nozzle blend radius, and Tables 1-9.1 and 1-9.2.2 (Curve C) and Figures 1-9.2.1 and 1-9.2.2 for both safe end locations].
Curve C is selected because it is the most conservative curve among the three extended curves for austenitic steel. VESLFAT automatically scales the stresses by the ratio of E on the fatigue curve to E in the analysis, for purposes of determining allowable numbers of cycles, as required by the ASME Code.Other material properties are input as follows: m 1.7, n = 0.3, parameters used to calculate Ke for the safe end location (both materials)
[3, Table NB-3228.5(b)-1]
m = 2.0, n = 0.2, parameters used to calculate K, for the nozzle blend radius location [3, Table NB-3228.5(b)-I]
m = 2.0, n = 0.2, parameters used to calculate K, for the nozzle blend radius location [3, Table NB-3228.5(b)-I]
E from fatigue curve = 28,300 ksi [3, Appendix I, Figure 1-9.2] for the safe end locations.
E from fatigue curve = 28,300 ksi [3, Appendix I, Figure 1-9.2] for the safe end locations.
E from fatigue curve = 30,000 ksi [3, Appendix I, Figure 1-9.1 ] for the nozzle blend radius location.3.5 Stress Indices Stress indices are calculated per Reference
E from fatigue curve = 30,000 ksi [3, Appendix I, Figure 1-9.1 ] for the nozzle blend radius location.
[2, Section 3.8]. For the safe end location and using the ANSYS thermal stress results, the membrane plus bending stress results are multiplied by K 3 and then are added to the peak thermal stress results to yield total thermal stress, taking guidance from Equation 11 of NB-3600 [3]. The total thermal stresses are then added to the total piping and total pressure stresses.C 1 = C 2 = C 3 = 1, because the ANSYS model is sufficient to account for the effects of gross structural discontinuity.
3.5     Stress Indices Stress indices are calculated per Reference [2, Section 3.8]. For the safe end location and using the ANSYS thermal stress results, the membrane plus bending stress results are multiplied by K3 and then are added to the peak thermal stress results to yield total thermal stress, taking guidance from Equation 11 of NB-3600 [3]. The total thermal stresses are then added to the total piping and total pressure stresses.
The path for Node 2166 does not contain a weld and, therefore, does not take the same guidance from NB-3600. However, the path for Node 3719 uses guidance and the following values from NB-3600 for an "as welded girth butt weld": K 1 = 1.2, From Table 3681(a)-I of NB-3600 [3]K 2 = 1.8, From Table 3681(a)-I of NB-3600 [3]K 3 = 1.7, From Table 3681(a)-I of NB-3600 [3]File No.: 0801038.303 Page 5 of 18 Revision:
C1 = C2 = C3 = 1, because the ANSYS model is sufficient to account for the effects of gross structural discontinuity. The path for Node 2166 does not contain a weld and, therefore, does not take the same guidance from NB-3600. However, the path for Node 3719 uses guidance and the following values from NB-3600 for an "as welded girth butt weld":
1 F0306-OIRO V Structural Integrity Associates, Inc.The K values listed above are used to multiply the Membrane plus Bending stress results of the pressure load and piping load to yield Total Stress. So, Ki * (Memb+Bend)pressure  
K1 = 1.2, From Table 3681(a)-I of NB-3600 [3]
= Total Stresspressure and K 2 * (Memb+Bend)piping  
K 2 = 1.8, From Table 3681(a)-I of NB-3600 [3]
= Total StressPiping.
K 3 = 1.7, From Table 3681(a)-I of NB-3600 [3]
4.0 CALCULATIONS Table 5 contains the stress components at the locations of interest for the 1,000 psi unit pressure stress case [1, Table 2]. Table 5 also contains the stress components for the attached piping load unit stress case [1, Table 3], which correspond to a reactor design temperature of 575'F [2, Section 3.1.7].The attached piping load stress components were applied assuming the same signs as the thermal stress, which yields the largest stress component ranges.The stress indices for each location and loading scenario are calculated in the previous section. These stress indices are used in the Excel workbooks described below.The calculations of all of the VESLFAT stress inputs are automated in Excel workbooks VY-VFAT-]i.xls (safe end-both materials) and VY-VFAT-2i.xls (nozzle blend radius). These files are organized with sheets labeled as follows:* Overview:
File No.: 0801038.303                                                                                   Page 5 of 18 Revision: 1 F0306-OIRO
Contains general information.
 
* Other Stresses:
V     StructuralIntegrity Associates, Inc.
Contains pressure and attached piping load stresses.
The K values listed above are used to multiply the Membrane plus Bending stress results of the pressure load and piping load to yield Total Stress. So, Ki * (Memb+Bend)pressure = Total Stresspressure and K2 * (Memb+Bend)piping = Total StressPiping.
As shown in Table 5, the pressure and thermal stresses use the membrane-plus-bending and total stress from the finite element analysis [1], and include stress indices where appropriate.
4.0     CALCULATIONS Table 5 contains the stress components at the locations of interest for the 1,000 psi unit pressure stress case [1, Table 2]. Table 5 also contains the stress components for the attached piping load unit stress case [1, Table 3], which correspond to a reactor design temperature of 575'F [2, Section 3.1.7].
Rearranger:
The attached piping load stress components were applied assuming the same signs as the thermal stress, which yields the largest stress component ranges.
There are 7 Rearranger sheets, one for each thermal transient as analyzed by ANSYS. In these sheets, thermal stresses are copied from Excel workbook VY-StressResults.xls, and rearranged to conform to VESLFAT input format (including switching the shear stress components Sxz and Syz as required by VESLFAT).
The stress indices for each location and loading scenario are calculated in the previous section. These stress indices are used in the Excel workbooks described below.
VY-StressResults.xls contains the results of the ANSYS stress linearization for each transient.
The calculations of all of the VESLFAT stress inputs are automated in Excel workbooks VY-VFAT-]i.xls (safe end-both materials) and VY-VFAT-2i.xls (nozzle blend radius). These files are organized with sheets labeled as follows:
The files contained within this workbook are shown in Table 10. Time-varying scale factors for the attached piping loads (based on path metal temperature) and pressure are determined, and used to scale the unit load case stresses, which are then added to the thermal stresses.
* Overview: Contains general information.
Since the attached piping loads can act in any direction, the stresses due to the attached piping loads are assigned the same sign as the thermal stresses to maximize the component stresses.Algebraic summation of all six stress components is performed for pressure, piping loads, and thermal stresses at each transient time step. The VESLFAT stress input also includes time-varying metal temperature, as obtained from the ANSYS output, which is used to determine temperature-dependent properties from the values in Table 3.VESLFAT: Contains the VESLFAT stress input, as obtained from the Rearranger sheets.Load set numbers are entered on this sheet, as defined in Table I and Table 2. These sheets are saved to VESLFAT input files VY-VFAT-]i.STR (safe end-Inconel), VY-VFAT2-1i.STR (safe end-Stainless Steel), and VY-VFAT-2i.STR (nozzle blend radius).File No.: 0801038.303 Page 6 of 18 Revision:
* Other Stresses: Contains pressure and attached piping load stresses. As shown in Table 5, the pressure and thermal stresses use the membrane-plus-bending and total stress from the finite element analysis [1], and include stress indices where appropriate.
1 F0306-O1RO W Structural Integrity Associates, Inc.5.0 RESULTS OF ANALYSIS Table 6, Table 7 and Table 8 provide the detailed calculated 60-year fatigue usage, as obtained from VESLFAT output files VY-VFAT-11.FAT (safe end-Inconel), VY-VFAT2-1LFAT (safe end-Stainless Steel), and VY-VFAT-2L.FAT (nozzle blend radius). All VESLFAT input and output files are saved in the project computer files associated with this calculation.
Rearranger: There are 7 Rearranger sheets, one for each thermal transient as analyzed by ANSYS. In these sheets, thermal stresses are copied from Excel workbook VY-StressResults.xls, and rearranged to conform to VESLFAT input format (including switching the shear stress components Sxz and Syz as required by VESLFAT). VY-StressResults.xls contains the results of the ANSYS stress linearization for each transient. The files contained within this workbook are shown in Table 10. Time-varying scale factors for the attached piping loads (based on path metal temperature) and pressure are determined, and used to scale the unit load case stresses, which are then added to the thermal stresses. Since the attached piping loads can act in any direction, the stresses due to the attached piping loads are assigned the same sign as the thermal stresses to maximize the component stresses.
From Table 6, the safe end (Inconel) cumulative usage factor (CUF) is 0.000174 for 60 years. From Table 7, the safe end (Stainless Steel) cumulative usage factor (CUF) is 0.000742 for 60 years.From Table 8, the nozzle blend radius CUF is 0.0171 for 60 years.From Table 1 of Reference
Algebraic summation of all six stress components is performed for pressure, piping loads, and thermal stresses at each transient time step. The VESLFAT stress input also includes time-varying metal temperature, as obtained from the ANSYS output, which is used to determine temperature-dependent properties from the values in Table 3.
[6], it was determined that hydrogen water chemistry (HWC) is available for 47% of the total 60-year operating period, and normal water chemistry (NWC) is present for the remaining 53% of the total 60-year operating period. From Table 1 of Reference
VESLFAT: Contains the VESLFAT stress input, as obtained from the Rearranger sheets.
[6], the dissolved oxygen values for the RPV upper vessel region (which is applicable to the CS nozzles) are 97 ppb for HWC conditions and 114 ppb for NWC conditions.
Load set numbers are entered on this sheet, as defined in Table I and Table 2. These sheets are saved to VESLFAT input files VY-VFAT-]i.STR (safe end-Inconel), VY-VFAT2-1i.STR (safe end-Stainless Steel), and VY-VFAT-2i.STR (nozzle blend radius).
For the safe end location (Inconel), the environmental fatigue factor is determined based on Alloy 600 methodology consistent with Reference
File No.: 0801038.303                                                                                   Page 6 of 18 Revision: 1 F0306-O1RO
[7]. The overall Fen (fatigue life correction factor), per Reference
 
[7], is 1.49 and can be applied to the CS nozzle safe end (Inconel) location based on identical materials, i.e. SB-166. The resulting Environmentally Assisted Fatigue (EAF) adjusted CUF value is 0.000174 x 1.49 = 0.000259, which is less than the allowable value of 1.0 and is therefore acceptable.
W StructuralIntegrityAssociates, Inc.
For the stainless steel piping, the environmental fatigue factors for post-HWC and pre-HWC are both 8.36 from Table 4 of Reference
5.0     RESULTS OF ANALYSIS Table 6, Table 7 and Table 8 provide the detailed calculated 60-year fatigue usage, as obtained from VESLFAT output files VY-VFAT-11.FAT (safe end-Inconel), VY-VFAT2-1LFAT (safe end-Stainless Steel), and VY-VFAT-2L.FAT (nozzle blend radius). All VESLFAT input and output files are saved in the project computer files associated with this calculation.
[6]. The overall environmental multiplier is 8.36. It results in an EAF adjusted CUF of 8.36 x 0.000742 = 0.00620 for 60 years, which is acceptable (i.e., less than the allowable value of 1.0).Based on the detailed CUF calculation shown in Table 8, a detailed EAF adjusted CUF evaluation on a load-pair basis is provided for the nozzle blend radius location in Table 9. The overall Fen is 8.20.The resulting EAF adjusted CUF value is 0.0171 x 8.20 = 0.140, which is less than the allowable value of 1.0 and is therefore acceptable.
From Table 6, the safe end (Inconel) cumulative usage factor (CUF) is 0.000174 for 60 years. From Table 7, the safe end (Stainless Steel) cumulative usage factor (CUF) is 0.000742 for 60 years.
From Table 8, the nozzle blend radius CUF is 0.0171 for 60 years.
From Table 1 of Reference [6], it was determined that hydrogen water chemistry (HWC) is available for 47% of the total 60-year operating period, and normal water chemistry (NWC) is present for the remaining 53% of the total 60-year operating period. From Table 1 of Reference [6], the dissolved oxygen values for the RPV upper vessel region (which is applicable to the CS nozzles) are 97 ppb for HWC conditions and 114 ppb for NWC conditions.
For the safe end location (Inconel), the environmental fatigue factor is determined based on Alloy 600 methodology consistent with Reference [7]. The overall Fen (fatigue life correction factor), per Reference [7], is 1.49 and can be applied to the CS nozzle safe end (Inconel) location based on identical materials, i.e. SB-166. The resulting Environmentally Assisted Fatigue (EAF) adjusted CUF value is 0.000174 x 1.49 = 0.000259, which is less than the allowable value of 1.0 and is therefore acceptable.
For the stainless steel piping, the environmental fatigue factors for post-HWC and pre-HWC are both 8.36 from Table 4 of Reference [6]. The overall environmental multiplier is 8.36. It results in an EAF adjusted CUF of 8.36 x 0.000742 = 0.00620 for 60 years, which is acceptable (i.e., less than the allowable value of 1.0).
Based on the detailed CUF calculation shown in Table 8, a detailed EAF adjusted CUF evaluation on a load-pair basis is provided for the nozzle blend radius location in Table 9. The overall Fen is 8.20.
The resulting EAF adjusted CUF value is 0.0171 x 8.20 = 0.140, which is less than the allowable value of 1.0 and is therefore acceptable.


==6.0 CONCLUSION==
==6.0     CONCLUSION==
S AND DISCUSSIONS Detailed fatigue calculations for the Vermont Yankee CS nozzle were performed based on the results of stress analyses previously performed
S AND DISCUSSIONS Detailed fatigue calculations for the Vermont Yankee CS nozzle were performed based on the results of stress analyses previously performed [1]. The thermal stresses were combined with stresses due to pressure and attached piping loads, both of which were scaled based on the magnitudes of the pressure and metal temperature during each thermal transient. All six components of the stress tensor were used for the fatigue calculations. The fatigue calculations were performed at previously-determined limiting locations in the safe end and nozzle blend radius, and used the methodology of Subarticle NB-3200 of Section III of the ASME Code [3].
[1]. The thermal stresses were combined with stresses due to pressure and attached piping loads, both of which were scaled based on the magnitudes of the pressure and metal temperature during each thermal transient.
The 60-year CUF for the safe end location (Inconel) was determined to be 0.000 174, the safe end location (Stainless Steel) was determined to be 0.000742, and the CUF for the nozzle blend radius File No.: 0801038.303                                                                                   Page 7 of 18 Revision: 1 F0306-O1RO
All six components of the stress tensor were used for the fatigue calculations.
The fatigue calculations were performed at previously-determined limiting locations in the safe end and nozzle blend radius, and used the methodology of Subarticle NB-3200 of Section III of the ASME Code [3].The 60-year CUF for the safe end location (Inconel) was determined to be 0.000 174, the safe end location (Stainless Steel) was determined to be 0.000742, and the CUF for the nozzle blend radius File No.: 0801038.303 Page 7 of 18 Revision:
1 F0306-O1RO Structural Integrity Associates, Inc.location was determined to be 0.0171. All three values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.
Detailed EAF assessments were also performed for the two CS nozzle locations.
The 60-year EAF CUF for the safe end location was determined to be 0.000259 using standard Alloy 600 methodology
[7]. The 60-year EAF CUF for the safe end location (Stainless Steel) was determined to be 0.00620.The 60-year EAF CUF for the nozzle blend radius location was determined to be 0.140 using temperature-dependent Fen multipliers for each load pair. All EAF CUF values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.


==7.0 REFERENCES==
StructuralIntegrity Associates, Inc.
: 1. Structural Integrity Associates Calculation No. 0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle." 2. Structural Integrity Associates Calculation No. 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle." 3. ASME Boiler and Pressure Vessel Code, Section III, 1998 Edition with 2000 Addenda.4. VESLFAT, Version 1.42, 02/06/07, Structural Integrity Associates.
location was determined to be 0.0171. All three values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.
: 5. ASME Boiler and Pressure Vessel Code, Section II, Part D-Properties, 1998 Edition with 2000 Addenda.6. SI Calculation No. VY-16Q-303, Revision 0, "Environmental Fatigue Evaluation of Reactor Recirculation Inlet Nozzle and Vessel Shell/Bottom Head." 7. EPRI Report No. TR-105759, "An Environmental Factor Approach to Account for Reactor Water Effects in Light Water Reactor Pressure Vessel and Piping Fatigue Evaluations," December 1995.8. Entergy Design Input Record (DIR) EC No. 1773, DIR. Revision 1, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY- 16Q-209.File No.: 0801038.303 Revision:
Detailed EAF assessments were also performed for the two CS nozzle locations. The 60-year EAF CUF for the safe end location was determined to be 0.000259 using standard Alloy 600 methodology
I Page 8 of 18 F0306-OI RO VStructural Integrity Associates, Inc.Table 1: Safe End Load Sets as Input to VESLFAT VESLFAT Load Set 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Start Transient tiee Time, sec Tm2 T1_ 0 Trn2T2_ 0 Trn2T3_ 0 1Tm3r 0 2Trn3 56.6 I1Tml 1- 0 2Trnl 1 5 3Tml 1 26.962 4Trn I 1 207.34 5TrnIl 1 1734.9 6Trnl 1 2332.6 7Trnl 1 5625.1 8Trnl 1 7125.4 9Trnl 1 14315 1OTrnl 1 16749 lTrnl4 0 2Tm14 270 lTrn21 0 2Trn2l 17.00 Tn24_TI_ 0 Tn24 T2 0 Tn24_T3_ 0 1Trn3O 0 2Trn3O 12.2 3Trn3O 631 Temp Change Pressure Change None None None Up Up None Down Down Down & Up Up & Down Down & Up Up & Down Down & Up Up & Down Down Down Down Down Down None None None Down Down None None Up Down Up Up Up & Down Down None None Down Down & UP Up & Down Down & Up Up None Down Down Down Down None Up Down Down Down Down Cycles 120 120 120 300 300 10 10 10 10 10 10 10 10 10 10 1 1 300 300 1 1 1 1 1 1 File No.: 0801038.303 Revision:
[7]. The 60-year EAF CUF for the safe end location (Stainless Steel) was determined to be 0.00620.
I Page 9 of 18 F0306-0IRO Structural Intearity Associates, Inc.Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT VESLFAT Load Set Transient Structurai Integrity Associates, Inc.Trn2_TI Trn2_T2_Trn2_T3_1Trn3_2Trn3 ITrnll1 2Trn I1_3Trnl 1 4Trnl 1 5Trnl I 6Trn 11 7Trnl I 8Trnl I 9Trnll1 1Trnl4_2 Tm14 2Trnl4_3Tm14 1Tmn21I 2Tin21I 3Tm2l1 Tn24_Ti1 Tn24 T2 Tn24_T3_1Tm30_2Tmn3O 3Tmn30 4Tmn30_Start Time, sec 0 0 0.0 56.6 0 5 142.64 1655.2 2302.7 3193.7 7255.1 9913 12514 0 40 1200 0 32.15 6462.7 0 0 0 0 1.2 25 3331 Temp Change Pressure Change Cycles None None None Up Up None Down Down & Up Up & Down Down & Up Up & Down Down & Up Up Up and Down Down Down Down Down Down Down None None None None Down Down Down None Up Down Up Up Up & Down Down None Down Down & Up Up & Down Down Down & Up Up Down Down Down Down Down None None Up Down Down Down Down Down 120 120 120 300 300 10 10 10 10 10 10 10 10 10 300 300 300 1 1 1 1 1 1 1 File No.: 0801038.303 Revision:
The 60-year EAF CUF for the nozzle blend radius location was determined to be 0.140 using temperature-dependent Fen multipliers for each load pair. All EAF CUF values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.
1 Page 10 of 18 F0306-O1RO Structural Integrity Associates, Inc.Table 3: Temperature-Dependent Material Properties for VESLFAT (4)Material T, OF E x 10 6 , psi S., ksi Sy, ksi SB-166 Inconel.(safe end(')* SA-508 Class 2 (5)(Nozzle blend radius (2))70 200 300 400 500 600 70 200 300 400 500 600 70 200 300 400 500 600 31.0 30.2 29.8 29.5 29.0 28.7 27.8 27.1 26.7 26.1 25.7 25.2 28.3 27.6 27.0 26.5 25.8 25.3 23.3 23.3 23.3 23.3 23.3 23.3 26.7 26.7 26.7 26.7 26.7 26.7 20 20 20 18.7 17.5 16.4 35.0 32.0 31.2 30.7 30.3 29.9 50.0 47.0 45.5 44.2 43.2 42.1 30 25 22.4 20.7 19.4 18.4 SA-312 TP 304 (Core Spray Piping 8 x 10 Reducer (3))Notes: 1. For the safe end material, SB-166 Inconel properties are used (72Ni-15Cr-8Fe), per Reference
[2]. Annealed heat treatment is conservatively assumed for Sm and Sy values.2. For the nozzle blend radius material, SA508 Class 2 material properties are used (3/4Ni-1/2Mo-1/3Cr-V), per Reference
[2].3. For the nozzle safe end extension material, SA-312 TP304 material properties are used (18Cr-8Ni), per Reference
[2].4. All values are taken from Reference
[5].5. SA-508 Class 2 in the Code of Construction is the same as SA-508 Gr. 2 Class 2 in the 1998 ASME Code [5]File No.: 0801038.303 Revision:
1 Page 11I of 18 F0306-O1RO 6 Structural Integrity Associates, Inc.Table 4: Carbon/Low Alloy Steel and Stainless Steel/Nickel Alloy Fatigue Curves Number of Cycles Sa, ksi Carbon/Low Alloy (1)S,, ksi Austenitic/Nickel Alloy 10 20 50 100 200 500 1000 2000 5000 10000 20000 50000 100000 200000 500000 1000000 2.E+06 5.E+06 1.E+07 2.E+07 5.E+07 1 .E+08 1.E+09 1.E+10 1.E+311 580 410 275 205 155 105 83 64 48 38 31 23 20 16.5 13.5 12.5 N/A N/A N/A N/A N/A N/A N/A N/A N/A 708 512 345 261 201 148 119 97 76 64 55.5 46.3 40.8 35.9 31 28.2 22.8(2)18.4(2)16.4(2)15.2(2)14.3(2)14.1(2)13.9(2)13.7(2)13.6(2)Note: 1. Using UTS _ 80 ksi curve.2. Using Curve C for austenitic steel/nickel alloy.File No.: 0801038.303 Revision:
I Page 12 of 18 F0306-OIRO Structural Integrity Associates, Inc.Table 5: Pressure and Attached Piping Unit Load Case Stress Components Membrane plus Bending (1) Total )Node S y"( s) (5) Sy S Sx Sz(s5)Load (2) Sx SY Sz Sy Sxz S S S Sxz yZ Pressure(3) 3719 -1011 4829 11010 -104.8 0 0 -1011 4912 11050 -85.31 0 0 2166 -1052 1657 25960 4886 0 0 -1052 1720 35050 348.9 0 0 Piping(4) 3719 0 6502 0 658 1222 0 0 11704 0 1184 2200 0 2166 0 82 0 30 20 0 0 82 0 30 20 0'MnM, 1 All ,an m , nnitc nfendf 2.3.4.5.The safe end location is represented by Node 3719, and the nozzle blend radius location is represented by Node 2166.The stresses for both nodes represent the stress due to an applied pressure of 1,000 psig.Piping stresses for both locations represent the stress due to full attached piping loads at an RPV temperature of 575'F.Sy. and S. components have been rearranged from the ANSYS output in order to be in correct order for VESLFAT.Table 6: Fatigue Usage Calculation for the Safe End (Inconel)Load#1 Load Desc. #1 #2 Salt Desc. #2 n (cvcles) Sn (psi) Ke (psi)Nallow U 24 17 5 5 5 5 5 5 5 5 5 4 4 1 19 19 3 3 2Trn3O 2Trn 14 2Trn3_2Trn3 2Trn3 2Tm3_2Trn3 2Trn3_2Trn3_2Trn3_2Trn3_1Trn3_1Trn3_Trn2_Ti1 2Trn2l_2Trn2l1 Trn2_T3_Trn2_T3_25 23.8 9 6 7 10 14 11 15.12 5 19 19 20 22 19 18 3Trn3O_1Trn30 3Trn 1_4Trn 11_1 Trn 11 2Tn I I_5Trnl 1_9Trn 1I-6Trnl 1_1OTrnl 11 7Trnl 1 2Trn3_2Trn21l 2Trn2l_Tn24_TI1 Tn24_T3_2Tm2l_1Trn21 1 1 10 10 10 10 10 10 10 10 10 210 90 120 1 1 88 32 67883 44360 26107 25551 24728 24429 23571 23593 23214 23358 23247 23000 22979 22979 22383 22383 22383 22389 63663 48903 18347 17850 16797 16784 16559 16507 16399 16262 15968 15922 15914 15899 15552 15552 15552 15549 10260 37919 5088300 6002500 8657500 8698300 9436700 9615800 10007000 10800000 12760000 13097000 13155000.13273000 16233000 16233000 16233000 16263000 Total Usage 0.000098 0.000026 0.000002 0.000002 0.000001 0.000001 0.000001 0.000001 0.000001 0.000001 0.000001 0.000016 0.000007 0.000009 0.000000 0.000000 0.000005 0.000002 0.000174 Note: All other load pairs have an alternating stress, they do not contribute to fatigue usage.Salt, that is below the endurance limit of the fatigue curve. Therefore, File No.: 0801038.303 Page 13 of 18 Revision:
1 F0306-0IRO Structural Integrity Associates, Inc.Table 7: Fatigue Usage Calculation for the Safe End (Stainless Steel)Load#1 24 17 5 5 5 5 5 5 5 5 4 4 1 19 19 3 3 Desc. #1 2Trn3O 2Trn 14 2Trn3 2Trn3 2Trn3 2Trn3_2Trn3_2Trn3_2Trn3_2Trn3_1 Trn3_1Trn3_Trn2 T1 2Trn21 2Trn2l Trn2 T3 Trn2_T3_Load#2 25 23 8 9 6 7 14 10 15 11 5 19 19 20 22 19 18 Desc. #2 3Trn3O_1 Trn30 3Trn 11_4Trn 11_1 Trn 11 2Trnl 1_9Trnl 1_5Trnl 11 1OTrnl 11 6Trn 1I-2Trn3_2Trn2l_2Trn2l_Tn24 Ti Tn24_T3_2Trn2l 1Trn21_n (cycles)1 1 10 10 10 10 10 10 10 10 22 Sn (psi)68465 44360 26107 25551 24728 24429 23593 23626 23358 23214 23000 22979 22979 22383 22383 22383 22389 Ke 1.47 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Salt (psi)101779 54103 20551 19856 18923 18905 18620 18525 18336 18295 17975 17967 17949 17557 17557 17557 17554 Nallow 1699.05 22751 3117000 3611400 4435200 4453400 4752000 4857700 5106400 5175200 5755400 5772000 5806200 6632000 6632000 6632000 6640000 Total Usage =U 0.000589 0.000044 0.000003 0.000003 0.000002 0.000002 0.000002 0.000002 0.000002 0.000002 0.000038 0.000014 0.000021 0.000000 0.000000 0.000015 0.000003 0.000742 Note: All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.File No.: 0801038.303 Revision:
1 Page 14 of 18 F0306-01RO VStructural Integrity Associates, Inc.Table 8: Fatigue Usage Calculation for the Nozzle Blend Radius Load Load n Salt#1 L Desc. #1 #2 Desc. #2 (cycles) Sn (psi) Ke (psi)Nallow U 25 2Trn3O0 26 3Trn3O0 8 3Trnl 1_ 13 8Trnl 1_19 2Trn21 22 Tn24_T2_7 2Trnl 1 27 4Trn3O0 4 1Trn3_ 7 2Trnl 1_10 5Trn11 _ 19 2Trn21l 1 Trn2 TI 6 1Trn 11 2 Trn2_T2_ 19 2Trn21, 12 7Trnl 1 19 2Trn21 1 Trn2_Ti1 9 4Trnl 1 4 1Trn3_ 11 6Trn 11_1 Trn2 T1 5 2Trn3 4 1Trn3_ 5 2Trn3_4 1Trn3_ 24 lTrn30-4 1Trn3_ 18 1Trn21_17 3Trn14_ 18 1Trn21_18 1Trn21_ 20 3Trn21_19 2Trn21_ 20 3Trn21_3 Trn2_T3_ 19 2Trn21l 3 Trn2 T3 14 9Trn 11_3 Trn2_T3_ 15 1Trn14_3 Trn2_T3_ 16 2Trn14_1 51402 1.00 44455 6278 0.0002 10 15961 1.00 39383 8994 0.0011 1 39644 1.00 34138 14404 0.0001 1 38618 1.00 27466 28999 0.0000 9 36665 1.00 27150 30048 0.0003 10 15935 1.00 26332 33005 0.0003 10 49693 1.00 25486 36486 0.0003 120 25423 1.00 24010 43822 0.0027 10 13983 1.00 23200 48691 0.0002 10 47005 1.00 22776 52484 0.0002 10 35885 1.00 22731 53008 0.0002 100 44974 1.00 22190 59737 0.0017 200 44974 1.00 22190 59737 0.0033 1 44912 1.00 22187 59767 0.0000 80 44912 1.00 22187 59767 0.0013 1 44598 1.00 21478 70216 0.0000 219 43608 1.00 21218 74590 0.0029 81 43426 1.00 21130 76147 0.0011 78 43219 1.00 21117 76367 0.0010 10 43408 1.00 21016 78221 0.0001 1 42722 1.00 20993 78639 0.0000 1 41044 1.00 20341 91957 0.0000 Total 0.0171 Usage =Note: All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.File No.: 0801038.303 Revision:
1 Page 15 of 18 F0306-OIRO C Structural Integrity Associates, Inc.Table 9: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location VY CS Nozzle Corner Environmental Fatigue Calculation CUF Calculation from file VY-VFAT-2i.fat:
Index Load #1: Description
#1: n 1 (cycles) t5) Load #2& Description
#2i n 2 (cycles) t5 ycles} 's SK psi t lt (psi} Nallmy U 1 25 2Trn30_ 1 26 i 3Trn3O_ 1 1 51402 1.00 44455 6278 0.0002 2 8 i 3Trnl_ 10 13 i 8Trn11_ i 10 10 15961 1-00 39383 8994 0.0011 3 19 i 2Trn21 300 22 Tn24 T2 ' 1 1 39644 1.00 34138 14404 0-0001 4 7 2Trnl1 10 27 4Trn30 1 1 38618 1-00 27466 28999 0.0000 5 4 1Trn3 300 7 2Trn11- 9 9 36665 1.00 27150 30048 0.0003 6 10 5Trn11 10 19 2Trn21 299 10 15935 1.00 26332 33005 0.0003 7 1 1 Trn2 TI 120 6 iTrnl 1 10 10 49693 1.00 25486. 36486 0.0003 8 2 Trn2 T2 120 19 2Trn2l 289 120 25423 1.00 24010 43822 0.0027 9 12 7Tlr 11 i 10 19 i 2Trn21- 169 10 13983 1.00 23200 48691 0.0002 10 1 ITrn2 Ti 110 9 4Trn11 10 10 47005 1.00 22776 52484 0.0002 11 4 1Trn3 291 11 6Trn11- 10 10 35885 1.00 22731 53008 0.0002 12 1 Trn2 T1 100 5 2Trn3 300 100 44974 1.00 22190 59737 0.0017 13 4 1Tr,3 281 2Trn3 200 200 44974 1.00 22190 59737 0.0033 14 4 1Trn3 81 24 OTrn3_ 1 1 44912 1.00 22187 59767 0.0000 15 4 lTrn3 80 18 1 Trn21 300 80 44912 1.00 22187 59767 0.0013 16 17 3Trn14 1 18 1Trn21_ 220 1 44598 1.00 21478 70216 0.0000 17 18 1Trn21 i 219 20 i 3Trn21 i 300 219 43608 1.00 21218 74590 0.0029 18 19 2Trn21 159 20 i 3Trn21 81 81 43426 1.00 21130 76147 0.0011 19 3 Trn2 T3 120 19 2Trn21 78 78 43219 1.00 21117 76367 0.0010 20 3 Trn2 T3 42 14 9Trn11- 10 10 43408 1.00 21016 78221 0.0001 21 3 Trn2 T3 32 15 1 Tm14- 1 1 42722 1.00 20993 78639 0.0000 22 3 Trn2 T3- 31 16 1 2Trn14 1 1 41044 1.00 20341 91957 0.1000 Total, U = 0.0171 File No.: 0801038.303 Revision:
I Page 16 of 18 F0306-0IRO Structural Integrity Associates, -Inc.Table 9 (Continued):
EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location EAF Calculations:
(00 and HWCINWC inputs fromTable 1 of Reference
[6})%, HWC =HWC DO 97 0.47 HWC D0O 114 0.53 ppb=% NWC Transient Maximum Temperatures:
Frnm "V'Y-VtFAT-2i AlII 'Index Load #1 Desc. #1 Load #21 Desc.#2 Line # Ti (4) si(4) T2(4) s2(4] Sn (psi) T (IF) (1)1 25 2Trn30- 26 3Trn3O 591851 25 15 26 30 51402 543 2 B 3Trnhl _ 13 UTrnh 1 -127122 8 30 13 14 15961 3D1 3 19 2Trn21 22 Tn24 T.2 574137 19 20 22 39644 359 4 7 2Trnl 1 27 4Trn30 107543 7 32 27 17 3561t 465 5 4 lTrn3_ 7 2Trnill 3921 4 1 7 32 36f665 465 6 10 5Trn 1- 19 2Trn2l 24a,706 10 67 19 20 15935 389 7 1 Trn2 Tl 6 lTrn 1. 70 1 1 6 4 49693 526 5 2 Trn2 T2_ 19 2Trn21_ 2028 2 1 19 20 25423 389 9 12 Tfrn 1I- 19 2Trn2i_ 391806 12 30 .19 20 13983 3&9 10 .1 Trn2_Ti1 9 4Trnll 161 1 1 9 1 47005 434 11 4 1Trn3_ 11 6Trnl 11 5546 4 1 11 1 35655 348 12 1 Trn2_TI_ 5 2Trn3_ 56 1 1 5 42 44974 549 13 4 lTrn3 5 2Trn3_ 3475 4 t1 5 42 44974 549 14 4 iTrn3_ 24 1Trn30_ 10815 4 1 24 1 44912 549 15 4 ITrn3_ 15 i Trn21_ 1016 4 1 18 1 44912 549 16 r 17 3Trn14_ 18 1Trn21_ 53601 3 17 111 16 1 44596 549 17 15 lTrn2i_ 20 3Trn21 571713 18 1 20 39 43605 549 15 19 2Trn21 20 3Trn21 573512 19 1 20 39 43426 549 19 3 Trn2 T3 19 2Trn21_ 3151 3 1 1,9 1 43219 549 20 3 Trn2 T3 14 9Trnll_ 296-5 3 1 14 155 43405 524 21 3 Trn2 T3 15 lTrn14 2979 3 1 15 1 42722 526 22 3 Trnm2T3 16 , 2Trn 14_ 2953 3 1 16 1 41044 524, TMAX -F) (1) TMAX ('C) HWC Fen (2) NWC Fen (2) Uenv (3)543 2.54 6.49 10.65 0.002 391 199 3.68 4.22 0.005 389 1 5'8 3.54 4.17 01.000 145 241 I 5.65 6.62 0.000 465 241 5.63 6.62 0.002 359 198 3.84 4.17 0.001 526 274 7.78 9.60 D.002 389 198 3.64 4.17 0.011 359 198 3.84 4.17 0.001 434 223 4.34 5.48 01.001 345 176 3.11 3.25 01.001 549 267 8.76 11.05 0.017 549 287 6.76 11.05 0.033 549 287 8.76 11.05 01.000 549 257 6.76 11.05 U..013 549 287 8.76 11.05 .0.000 549 287 8.76 11.05 0.029 549 297 6.76 11.05 0c.011 549 287 8.76a 11.05 01.010 524 273 7.70 49 0.001 526 274 7.75 9.60 0.000 524 273 7.70 9.89 01.000 Total. U =Overall Fen Notes: 1. Tv,,., is the maximum temperature of the two paired load states, and represents the metal (nodal) temperature at the location being analzed. This, which is include-d as 'T in the'Transient Maximum Temperatures7' table above. determined from the VESLFAT 2. F, values computed using the low alloy steel equation from Section 3.0 of Reference
[61 with S' conservatively set to a maximum value of 0.0 15. and the transtformed strain rate conservat~rely set to a minimum value of In (0.00t1) = 508 for all load 3. = [U x HWC F, x % HWCI [U x NWC F_. x % NWC1.4. T1 and 72 represent the load number for Load #1 and Load #2, respectively, and sl and s2 represent the state number for each 5. For each load pair, nj is the number of available cycles for Load #1, n- is the number of available cycles for Load #2, and n is the available number of cycles for the load pair (i.e., the minimum of nj and n.).0.140 8.20 File No.: 0801038.303 Revision:
1 Page 17 of 18 F0306-OI RO SStructural Integrity Associates, Inc.Table 10: Linearized Stress Files Compiled for VY-StressResults.xls Filename Description vyl 6qtran2-s.csv vyl 6q_tran3-s.csv vy_l 6q_tranl 1-s.csv vyl 6q_tran 1 4-s.csv vyl 6q_tran21-23-s.csv vyl 6q_tran24-s.csv vyl 6q_tran30-s.csv Transient 2 linearized stress Transient 3 linearized stress Transient 11 linearized stress Transient 14 linearized stress Transients 21-23 linearized stress Transient 24 linearized stress Transient 30 linearized stress Note: All files are from the supporting computer files associated with Reference
[1].File No.: 0801038.303 Revision:
I Page 18 of 18 F0306-OIRO Structural Integrity Associates, Inc. File No.: 0801038.304 CALCULATION PACKAGE Project No.: 0801038 Quality Program: Z Nuclear [ Commercial PROJECT NAME: VY Confirmatory Analysis for CS and RO Nozzles CONTRACT NO.: 10163217 Amendment 5 CLIENT: PLANT: Entergy Nuclear Operations, Inc Vermont Yankee Nuclear Power Station CALCULATION TITLE: Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle Document Affected Project Manager Preparer(s)
&Documen afe Revision Description Approval Checker(s)
Revision Pages Signature
& Date Signatures
& Date 01 -20, Initial issue. Preparers:
Appendix:
Gary L. Stevens Michael J. Minard A- I -A-23 01/07/09 01/07/09 Computer files. Tyler D. Novotny 01/07/09 Checker: Terry J. Herrmann 01/07/09 1 1-8,10,11, Revised per summary. / Preparer: 13-20, contained in Section 1.1. ,. 0( 11Z64-A-2 Changes are marked with "revision bars" in Gary L. Stevens right-hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker: William Weitze 03/09/09 Page 1 of 20 F0306-01 RO Structural Integrity Associates, Inc.Table of Contents 1.0 OBJECTIVE
............................................................................................................
4 1.1 Changes M ade in Revision 1 of this Calculation
..........................................
4 2.0 M ETHODOLOGY
...................................................................................................
4 3.0 ASSUM PTIONS / DESIGN INPUTS .......................................................................
5 3.1 Assumptions
...............................................................................................
.. 5 3.2 ASM E Code Edition .....................................................................................
5 3.3 Transients
......................................................................................................
6 3.4 Heat Transfer Coefficients
.............................................................
......6 3.5 Finite Element M odel ..................................................................................
8 3.6 Nozzle Blend Radius Pressure Stress ..........................................................
8 3.7 Piping Interface Loads...............................................................................
.........
8 3.8 SCFs, Safe End ............................................................................................
9 3.9 Environmental Fatigue M ultipliers
................................................................
9 4.0 CALCULATIONS
...............
..................................................................................
13 4.1 Piping Interface Loads ....................................
13 5.0 RESULTS OF ANALYSIS .....................................................................................
18


==6.0 REFERENCES==
==7.0    REFERENCES==
: 1. Structural Integrity Associates Calculation No. 0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle."
: 2. Structural Integrity Associates Calculation No. 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle."
: 3. ASME Boiler and Pressure Vessel Code, Section III, 1998 Edition with 2000 Addenda.
: 4. VESLFAT, Version 1.42, 02/06/07, Structural Integrity Associates.
: 5. ASME Boiler and Pressure Vessel Code, Section II, Part D-Properties, 1998 Edition with 2000 Addenda.
: 6. SI Calculation No. VY-16Q-303, Revision 0, "Environmental Fatigue Evaluation of Reactor Recirculation Inlet Nozzle and Vessel Shell/Bottom Head."
: 7. EPRI Report No. TR-105759, "An Environmental Factor Approach to Account for Reactor Water Effects in Light Water Reactor Pressure Vessel and Piping Fatigue Evaluations,"
December 1995.
: 8. Entergy Design Input Record (DIR) EC No. 1773, DIR. Revision 1, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY- 16Q-209.
File No.: 0801038.303                                                                              Page 8 of 18 Revision: I F0306-OI RO
 
VStructural IntegrityAssociates, Inc.
Table 1: Safe End Load Sets as Input to VESLFAT VESLFAT                  Start  Temp Change Pressure Change Transient  tiee                                Cycles Load Set            Time, sec Tm2 T1_        0      None        None        120 2      Trn2T2_        0        None          Up        120 3      Trn2T3_        0        None        Down        120 4        1Tm3r        0        Up            Up        300 5        2Trn3      56.6      Up            Up        300 6      I1Tml 1-      0        None      Up & Down      10 7      2Trnl 1        5      Down          Down        10 8      3Tml 1    26.962    Down          None        10 9      4Trn I 1  207.34  Down & Up      None        10 10      5TrnIl 1  1734.9  Up & Down      Down        10 11      6Trnl 1  2332.6    Down & Up    Down & UP      10 12      7Trnl 1    5625.1  Up & Down    Up & Down      10 13      8Trnl 1    7125.4  Down & Up    Down & Up      10 14      9Trnl 1    14315    Up & Down        Up        10 15      1OTrnl 1    16749      Down          None        10 16      lTrnl4        0      Down          Down        1 17      2Tm14        270      Down          Down        1 18      lTrn21        0      Down          Down        300 19      2Trn2l      17.00    Down          Down        300 20      Tn24_TI_      0        None        None        1 21      Tn24 T2        0        None          Up        1 22      Tn24_T3_      0        None        Down        1 23        1Trn3O        0      Down          Down        1 24        2Trn3O      12.2    Down          Down        1 25        3Trn3O      631      None        Down        1 File No.: 0801038.303                                                                  Page 9 of 18 Revision: I F0306-0IRO
 
StructuralIntearity Associates, Inc.
Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT Start VESLFAT Transient  Time,  Temp Change Pressure Change Cycles Load Set sec Inc.
Trn2_TI        0      None          None      120 Associates, Structurai Integrity Trn2_T2_      0      None          Up        120 Trn2_T3_      0      None        Down        120 1Trn3_    .0        Up            Up        300 2Trn3      56.6      Up            Up        300 ITrnll1      0      None      Up & Down      10 2Trn I1_      5      Down          Down        10 3Trnl 1  142.64  Down & Up      None        10 4Trnl 1  1655.2  Up & Down      Down        10 5Trnl I  2302.7  Down & Up    Down & Up      10 6Trn 11  3193.7  Up & Down    Up & Down      10 7Trnl I  7255.1  Down & Up      Down        10 8Trnl I    9913        Up      Down & Up      10 9Trnll1    12514  Up and Down        Up        10 1Trnl4_      0      Down          Down 2Tm14 2Trnl4_      40      Down          Down 3Tm14      1200    Down          Down 1Tmn21I      0      Down          Down        300 2Tin21I    32.15    Down          Down        300 3Tm2l1    6462.7    Down          None        300 Tn24_Ti1      0      None        None        1 Tn24 T2        0      None          Up        1 Tn24_T3_      0      None        Down        1 1Tm30_        0      None        Down        1 2Tmn3O      1.2    Down          Down        1 3Tmn30      25      Down          Down        1 4Tmn30_    3331      Down          Down        1 File No.: 0801038.303                                                                    Page 10 of 18 Revision: 1 F0306-O1RO
 
StructuralIntegrityAssociates, Inc.
Table 3: Temperature-Dependent Material Properties for VESLFAT                                  (4)
Material              T, OF  E x 106 , psi    S., ksi    Sy, ksi SB-166 Inconel            70        31.0          23.3        35.0
                                    .(safe end(')            200        30.2          23.3        32.0 300      29.8            23.3        31.2 400        29.5            23.3        30.7 500      29.0            23.3        30.3 600        28.7            23.3        29.9
* SA-508  Class 2 (5)        70      27.8            26.7        50.0 (Nozzle blend radius    (2)) 200        27.1            26.7        47.0 300        26.7            26.7        45.5 400        26.1            26.7        44.2 500      25.7            26.7        43.2 600        25.2            26.7        42.1 SA-312 TP 304              70      28.3            20          30 (Core Spray Piping                    27.6 200                        20          25 8 x 10 Reducer (3))
300        27.0            20        22.4 400        26.5            18.7        20.7 500        25.8            17.5        19.4 600        25.3            16.4        18.4 Notes:
: 1. For the safe end material, SB-166 Inconel properties are used (72Ni-15Cr-8Fe), per Reference [2]. Annealed heat treatment is conservatively assumed for Sm and Sy values.
: 2. For the nozzle blend radius material, SA508 Class 2 material properties are used (3/4Ni-1/2Mo-1/3Cr-V), per Reference [2].
: 3. For the nozzle safe end extension material, SA-312 TP304 material properties are used (18Cr-8Ni), per Reference [2].
: 4. All values are taken from Reference [5].
: 5. SA-508 Class 2 in the Code of Construction is the same as SA-508 Gr. 2 Class 2 in the 1998 ASME Code [5]
File No.: 0801038.303                                                                                                    Page 11I of 18 Revision: 1 F0306-O1RO
 
6      StructuralIntegrityAssociates, Inc.
Table 4: Carbon/Low Alloy Steel and Stainless Steel/Nickel Alloy Fatigue Curves Sa, ksi                        S,, ksi Number of Cycles      Carbon/Low Alloy (1)        Austenitic/Nickel Alloy 10                580                          708 20                410                            512 50                275                            345 100                205                            261 200                155                          201 500                105                          148 1000                  83                          119 2000                  64                            97 5000                  48                            76 10000                38                            64 20000                  31                          55.5 50000                  23                          46.3 100000                  20                          40.8 200000                16.5                          35.9 500000                13.5                            31 1000000              12.5                          28.2 2.E+06                N/A                          22.8(2) 5.E+06                N/A                          18.4(2) 1.E+07              N/A                          16.4(2) 2.E+07                N/A                          15.2(2) 5.E+07              N/A                          14.3(2) 1.E+08              N/A                          14.1(2) 1.E+09              N/A                          13.9(2) 1.E+10              N/A                          13.7(2) 1.E+311              N/A                          13.6(2)
Note:
: 1. Using UTS _ 80 ksi curve.
: 2. Using Curve C for austenitic steel/nickel alloy.
File No.: 0801038.303                                                                        Page 12 of 18 Revision: I F0306-OIRO
 
StructuralIntegrityAssociates, Inc.
Table 5: Pressure and Attached Piping Unit Load Case Stress Components Membrane plus Bending (1)                                                  Total    )
Node                                                          S  y"(
s)                    Sy    (5)  S          Sx            Sz(s5)
Load          (2)        Sx            SY          Sz      Sy      Sxz                S            S            S                Sxz      yZ Pressure(3)      3719      -1011          4829      11010    -104.8      0    0      -1011        4912        11050      -85.31    0        0 2166      -1052          1657      25960      4886        0    0      -1052          1720      35050        348.9    0        0 Piping(4)      3719        0            6502          0        658      1222    0          0          11704          0        1184  2200      0 2166          0            82          0        30        20    0          0            82          0          30    20        0
        'MnM,      1    All  otr*-oc ,an m or*  ,  nnitc nfendf
: 2. The safe end location is represented by Node 3719, and the nozzle blend radius location is represented by Node 2166.
: 3. The stresses for both nodes represent the stress due to an applied pressure of 1,000 psig.
: 4. Piping stresses for both locations represent the stress due to full attached piping loads at an RPV temperature of 575'F.
: 5. Sy. and S. components have been rearranged from the ANSYS output in order to be in correct order for VESLFAT.
Table 6: Fatigue Usage Calculation for the Safe End (Inconel)
Load                            Load                                                                    Salt
        #1        Desc. #1            #2        Desc. #2        n (cvcles)    Sn (psi)        Ke        (psi)          Nallow          U 24        2Trn3O              25        3Trn3O_                1        67883                    63663          10260      0.000098 17        2Trn 14              23        1Trn30                1        44360                    48903          37919        0.000026 5          2Trn3_            .8        3Trn 1_              10        26107                      18347        5088300      0.000002 5          2Trn3              9        4Trn 11_              10        25551                      17850        6002500      0.000002 5          2Trn3              6        1Trn 11              10        24728                      16797        8657500      0.000001 5          2Tm3_              7        2Tn I I_              10        24429                      16784        8698300      0.000001 5          2Trn3              10        5Trnl 1_              10        23571                      16559        9436700      0.000001 5          2Trn3_            14        9Trn 1I-              10        23593                      16507        9615800      0.000001 5          2Trn3_            11        6Trnl 1_              10        23214                      16399        10007000      0.000001 5          2Trn3_            15        1OTrnl 11            10        23358                      16262        10800000      0.000001 5          2Trn3_            .12        7Trnl 1              10        23247                      15968        12760000      0.000001 4          1Trn3_              5          2Trn3_            210        23000                      15922        13097000      0.000016 4          1Trn3_              19        2Trn21l              90        22979                      15914        13155000      0.000007 1      Trn2_Ti1              19        2Trn2l_              120        22979                      15899      .13273000      0.000009 19        2Trn2l_            20      Tn24_TI1                1        22383                      15552        16233000      0.000000 19        2Trn2l1            22      Tn24_T3_                1        22383                      15552        16233000      0.000000 3      Trn2_T3_              19      2Tm2l_                88        22383                      15552        16233000      0.000005 3      Trn2_T3_              18        1Trn21              32        22389                      15549        16263000      0.000002 Total Usage        0.000174 Note:    All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.
File No.: 0801038.303                                                                                                                  Page 13 of 18 Revision: 1 F0306-0IRO
 
StructuralIntegrity Associates, Inc.
Table 7: Fatigue Usage Calculation for the Safe End (Stainless Steel)
Load                      Load                                                              Salt Desc. #1                  Desc. #2      n (cycles)        Sn (psi)    Ke                      Nallow          U
        #1                      #2                                                              (psi) 24      2Trn3O          25        3Trn3O_            1            68465      1.47      101779        1699.05      0.000589 17      2Trn 14          23        1Trn30              1            44360        1      54103          22751      0.000044 5      2Trn3            8        3Trn 11_          10            26107        1      20551          3117000    0.000003 5      2Trn3            9        4Trn 11_          10            25551        1      19856          3611400    0.000003 5      2Trn3            6        1Trn 11            10            24728        1      18923          4435200    0.000002 5      2Trn3_          7        2Trnl 1_          10            24429        1      18905        4453400      0.000002 5      2Trn3_          14        9Trnl 1_          10            23593        1      18620        4752000      0.000002 5      2Trn3_          10        5Trnl 11          10            23626        1      18525        4857700      0.000002 5      2Trn3_          15        1OTrnl 11          10            23358        1      18336          5106400    0.000002 5      2Trn3_          11        6Trn 1I-          10            23214        1      18295        5175200      0.000002 4        1Trn3_          5        2Trn3_                          23000        1      17975          5755400    0.000038 4        1Trn3_        19        2Trn2l_                          22979        1      17967          5772000    0.000014 1    Trn2 T1          19        2Trn2l_                          22979        1      17949          5806200    0.000021 19      2Trn21          20      Tn24 Ti                          22383        1      17557        6632000      0.000000 19      2Trn2l          22      Tn24_T3_                          22383        1      17557        6632000      0.000000 3    Trn2 T3          19        2Trn2l                          22383        1      17557        6632000      0.000015 3    Trn2_T3_          18        1Trn21_            22            22389        1      17554        6640000      0.000003 Total 0.000742 Usage =
Note:  All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.
File No.: 0801038.303                                                                                                    Page 14 of 18 Revision: 1 F0306-01RO
 
VStructural IntegrityAssociates, Inc.
Table 8: Fatigue Usage Calculation for the Nozzle Blend Radius Load
            #1      Desc. #1      Load L#2        Desc. #2            n (cycles)        Sn (psi)    Ke      Salt (psi)          Nallow        U 25      2Trn3O0        26        3Trn3O0              1        51402    1.00    44455          6278      0.0002 8      3Trnl 1_        13      8Trnl 1_            10          15961    1.00    39383          8994      0.0011 19      2Trn21        22      Tn24_T2_              1        39644    1.00    34138          14404      0.0001 7      2Trnl 1        27        4Trn3O0              1        38618    1.00    27466          28999      0.0000 4        1Trn3_        7        2Trnl 1_            9          36665    1.00    27150          30048      0.0003 10      5Trn11 _      19        2Trn21l            10          15935    1.00    26332          33005      0.0003 1      Trn2 TI          6        1Trn 11            10          49693    1.00    25486          36486      0.0003 2      Trn2_T2_        19        2Trn21,            120          25423    1.00    24010          43822      0.0027 12      7Trnl 1        19        2Trn21              10          13983    1.00    23200          48691      0.0002 1      Trn2_Ti1        9        4Trnl 1            10          47005    1.00    22776          52484      0.0002 4        1Trn3_        11        6Trn 11_            10          35885    1.00    22731          53008      0.0002 1      Trn2 T1          5        2Trn3            100          44974    1.00    22190          59737      0.0017 4        1Trn3_        5        2Trn3_          200          44974    1.00    22190          59737      0.0033 4        1Trn3_        24        lTrn30-              1          44912    1.00    22187          59767      0.0000 4        1Trn3_        18        1Trn21_            80          44912    1.00    22187          59767      0.0013 17      3Trn14_        18        1Trn21_              1          44598    1.00    21478          70216      0.0000 18      1Trn21_        20        3Trn21_          219          43608    1.00    21218          74590      0.0029 19      2Trn21_        20        3Trn21_            81          43426    1.00    21130          76147      0.0011 3      Trn2_T3_        19        2Trn21l            78          43219    1.00    21117          76367      0.0010 3      Trn2 T3        14        9Trn 11_            10          43408    1.00    21016          78221      0.0001 3      Trn2_T3_        15        1Trn14_              1          42722    1.00    20993          78639      0.0000 3      Trn2_T3_        16        2Trn14_              1          41044    1.00    20341          91957      0.0000 Total      0.0171 Usage =
Note:  All other load pairs have an alternating stress, Salt,  that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.
File No.: 0801038.303                                                                                                      Page 15 of 18 Revision: 1 F0306-OIRO
 
C      StructuralIntegrity Associates, Inc.
Table 9: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location VY CS Nozzle Corner Environmental Fatigue Calculation CUF Calculation from file VY-VFAT-2i.fat:
Index  Load #1: Description #1: n1 (cycles) t5) Load #2&Description #2i n 2 (cycles) t5 ycles} 's SK psi  t    lt (psi}  Nallmy        U 1        25        2Trn30_            1        26  i  3Trn3O_              1          1      51402 1.00 44455      6278      0.0002 2        8    i    3Trnl_          10        13  i  8Trn11_    i      10        10      15961 1-00 39383      8994      0.0011 3        19    i    2Trn21          300        22      Tn24 T2      '        1          1      39644  1.00 34138      14404      0-0001 4        7          2Trnl1          10        27      4Trn30              1          1      38618 1-00 27466      28999      0.0000 5        4          1Trn3          300        7      2Trn11-              9          9      36665 1.00 27150      30048      0.0003 6        10          5Trn11          10        19      2Trn21            299        10      15935 1.00 26332      33005      0.0003 7        1    1 Trn2 TI            120        6    iTrnl 1              10        10      49693  1.00 25486. 36486      0.0003 8        2        Trn2 T2          120        19      2Trn2l            289        120      25423  1.00 24010      43822      0.0027 9        12          7Tlr 11    i    10        19 i    2Trn21-            169        10      13983 1.00 23200      48691      0.0002 10        1      ITrn2 Ti            110        9      4Trn11              10        10      47005  1.00 22776      52484      0.0002 11        4          1Trn3          291        11      6Trn11-            10        10      35885 1.00 22731      53008      0.0002 12        1        Trn2 T1          100        5        2Trn3            300        100      44974  1.00 22190      59737      0.0017 13        4          1Tr,3          281                  2Trn3            200        200      44974 1.00 22190      59737      0.0033 14        4          1Trn3          81        24            OTrn3_        1          1      44912  1.00 22187      59767      0.0000 15        4          lTrn3          80        18    1 Trn21              300        80      44912 1.00 22187      59767      0.0013 16        17          3Trn14            1        18      1Trn21_            220          1      44598  1.00 21478      70216      0.0000 17        18          1Trn21    i    219        20 i    3Trn21      i      300      219      43608  1.00 21218      74590      0.0029 18        19        2Trn21          159        20  i  3Trn21              81        81      43426  1.00 21130      76147      0.0011 19        3        Trn2 T3          120        19      2Trn21              78        78      43219 1.00 21117      76367      0.0010 20        3        Trn2 T3          42        14      9Trn11-            10        10      43408  1.00 21016      78221      0.0001 21        3        Trn2 T3          32        15      1Tm14-              1          1      42722  1.00 20993      78639      0.0000 22        3        Trn2 T3-          31        16  1 2Trn14                1          1      41044  1.00 20341      91957      0.1000 Total, U =  0.0171 File No.: 0801038.303                                                                                                                Page 16 of 18 Revision: I F0306-0IRO
 
Structural Integrity Associates, -Inc.
Table 9 (Continued): EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location EAF Calculations:              HWC DO      HWC D0O (00 and HWCINWC inputs fromTable 1 of Reference [6})        97          114          ppb Transient Maximum Temperatures:                                                                                                                    %, HWC =      0.47        0.53        =%NWC Frnm "V'Y-VtFAT-2i AlII '
Index    Load #1    Desc. #1 Load #21 Desc.#2        Line #    Ti (4) si(4) T2(4) s2(4] Sn (psi) T (IF) (1)                  TMAX -F) (1)    TMAX ('C)    HWC Fen (2)NWC Fen (2)  Uenv (3) 1        25      2Trn30-      26        3Trn3O    591851      25    15      26      30    51402        543                      543          2.54        6.49        10.65        0.002 2          B      3Trnhl _    13        UTrnh1 -  127122        8    30      13      14    15961        3D1                      391          199        3.68        4.22        0.005 3        19      2Trn21      22      Tn24 T.2    574137      19    20      22            39644        359                      389            1 5'8      3.54        4.17        01.000 4          7      2Trnl 1      27        4Trn30    107543        7    32      27      17    3561t        465                          145      241    I    5.65        6.62        0.000 5          4        lTrn3_      7      2Trnill    3921        4      1      7      32    36f665      465                      465          241        5.63        6.62        0.002 6        10      5Trn 1-      19      2Trn2l    24a,706      10    67      19      20    15935        389                      359          198        3.84        4.17        0.001 7          1      Trn2 Tl        6        lTrn 1.      70        1      1      6      4    49693        526                      526          274        7.78        9.60        D.002 5          2      Trn2 T2_      19      2Trn21_    2028        2      1      19      20    25423        389                      389          198        3.64        4.17        0.011 9        12      Tfrn 1I-    19      2Trn2i_    391806      12    30    .19      20    13983        3&9                      359          198        3.84        4.17        0.001 10        .1      Trn2_Ti1      9        4Trnll      161        1      1      9      1    47005        434                      434          223        4.34        5.48        01.001 11          4        1Trn3_      11      6Trnl 11    5546        4      1      11      1    35655        348                      345          176        3.11        3.25        01.001 12          1      Trn2_TI_      5        2Trn3_      56        1      1      5      42    44974        549                      549          267        8.76        11.05        0.017 13          4        lTrn3        5        2Trn3_    3475        4      t1      5      42    44974        549                      549          287        6.76        11.05        0.033 14          4        iTrn3_      24        1Trn30_    10815        4      1      24      1    44912        549                      549          287        8.76        11.05        01.000 15          4        ITrn3_      i 15        Trn21_    1016        4      1      18      1    44912        549                      549          257        6.76        11.05        U..013 16r        17      3Trn14_      18        1Trn21_  53601 3      17    111      16      1    44596        549                      549          287        8.76        11.05        .0.000 17          15      lTrn2i_      20        3Trn21    571713      18      1      20      39    43605        549                      549          287        8.76        11.05        0.029 15        19      2Trn21      20        3Trn21    573512      19      1      20      39    43426        549                      549          297        6.76        11.05        0c.011 19          3      Trn2 T3      19      2Trn21_    3151        3      1      1,9      1    43219        549                      549          287        8.76a      11.05        01.010 524          273        7.70          49        0.001 20          3      Trn2 T3      14      9Trnll_    296-5        3      1      14    155    43405        524 21          3      Trn2 T3        15      lTrn14      2979        3      1      15      1    42722        526                      526          274        7.75        9.60        0.000 22          3      Trnm2T3      16    , 2Trn 14_    2953        3      1      16      1    41044        524,                    524          273        7.70        9.89        01.000 Total. U =      0.140 Notes:  1.Tv,,., is the maximum temperature of the two paired load states, and represents the metal (nodal) temperature at the location                                  Overall Fen      8.20 being analzed. This, which is include-d as 'T in the'Transient Maximum Temperatures7' table above. determined from the VESLFAT
: 2. F, values computed using the low alloy steel equation from Section 3.0 of Reference [61 with S' conservatively set to a maximum value of 0.0 15. and the transtformed strain rate conservat~rely set to a minimum value of In (0.00t1) = 508 for all load
: 3. U*, = [U x HWC F, x % HWCI [U x NWC F_. x % NWC1.
: 4. T1 and 72 represent the load number for Load #1 and Load #2, respectively, and sl and s2 represent the state number for each
: 5. For each load pair, nj is the number of available cycles for Load #1, n- is the number of available cycles for Load #2, and n is the available number of cycles for the load pair (i.e., the minimum of nj and n.).
File No.: 0801038.303                                                                                                                                                                Page 17 of 18 Revision: 1 F0306-OI RO
 
SStructuralIntegrity Associates, Inc.
Table 10: Linearized Stress Files Compiled for VY-StressResults.xls Filename                        Description vyl 6qtran2-s.csv            Transient 2 linearized stress vyl 6q_tran3-s.csv          Transient 3 linearized stress vy_l 6q_tranl 1-s.csv        Transient 11 linearized stress vyl 6q_tran 14-s.csv        Transient 14 linearized stress vyl 6q_tran21-23-s.csv      Transients 21-23 linearized stress vyl 6q_tran24-s.csv          Transient 24 linearized stress vyl 6q_tran30-s.csv          Transient 30 linearized stress Note: All files are from the supporting computer files associated with Reference [1].
File No.: 0801038.303                                                                            Page 18 of 18 Revision: I F0306-OIRO
 
StructuralIntegrity Associates, Inc.                File No.: 0801038.304 CALCULATION PACKAGE                                Project No.: 0801038 Quality Program: Z Nuclear  [ Commercial PROJECT NAME:
VY Confirmatory Analysis for CS and RO Nozzles CONTRACT NO.:
10163217 Amendment 5 CLIENT:                                            PLANT:
Entergy Nuclear Operations, Inc                  Vermont Yankee Nuclear Power Station CALCULATION TITLE:
Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle Document        Affected                                    Project Manager            Preparer(s) &
Documen          afe          Revision Description          Approval                Checker(s)
Revision          Pages                                    Signature  & Date        Signatures & Date 01              - 20,            Initial issue.                              Preparers:
Appendix:                                    Gary L. Stevens        Michael J. Minard A- I - A-23                                      01/07/09                01/07/09 Computer files.                                                        Tyler D. Novotny 01/07/09 Checker:
Terry J. Herrmann 01/07/09 1          1-8,10,11,      Revised per summary.      /                      Preparer:
13-20,      contained in Section 1.1.            0(,. 11Z64-A-2          Changes are marked with "revision bars" in      Gary L. Stevens right-hand margin.            03/09/09            Tyler D. Novotny 03/09/09 Checker:
William Weitze 03/09/09 Page 1 of 20 F0306-01 RO
 
StructuralIntegrity Associates, Inc.
Table of Contents 1.0    OBJECTIVE ............................................................................................................            4 1.1      Changes M ade in Revision 1 of this Calculation ..........................................                                    4 2.0    M ETHODOLOGY ...................................................................................................                  4 3.0    ASSUM PTIONS / DESIGN INPUTS .......................................................................                              5 3.1      Assumptions ...............................................................................................                .. 5 3.2      ASM E Code Edition .....................................................................................                      5 3.3      Transients ......................................................................................................            6 3.4      Heat Transfer Coefficients .............................................................                          ...... 6 3.5      Finite Element M odel ..................................................................................                      8 3.6      Nozzle Blend Radius Pressure Stress ..........................................................                                8 3.7      Piping Interface Loads...............................................................................              ......... 8 3.8      SCFs, Safe End ............................................................................................                  9 3.9      Environmental Fatigue M ultipliers ................................................................                          9 4.0    CALCULATIONS ............... ..................................................................................                13 4.1      Piping Interface Loads ....................................                                                                13 5.0    RESULTS OF ANALYSIS .....................................................................................                      18
 
==6.0     REFERENCES==
........................................................................................................            19 APPENDIX A: ANSYS INPUT FILE: RON VY.INP .................................................                                          A-1 FileNo.: 0801038.304                                                                                                                      Page 2 of 20 Revision: 1 F0306-01!
 
VStructural integrity Associates, Inc.
List of Tables Table 1: Vessel and Nozzle/Safe End Transients .............................................................                    10 Table 2: H eat Transfer Coefficients ....................................................................................... 11 Table 3: Temperature-Dependent Material Properties ...........................................................                  11 Table 4: Recirculation Outlet Nozzle Attached Piping Loads and Dimensions [9, 11] ......... 14 Table 5: Membrane Plus Bending Stresses Due to Piping Loads ....................................                                14 Table 6: 0% Flow Regions I and 3 Heat Transfer Coefficients .......................................                            15 Table 7: 0% Flow Region 5 Heat Transfer Coefficient ...................................................                        16 List of Figures Figure 1: Nozzle and Vessel Wall Thermal Boundaries ...................................................                        12 Figure 2: Coordinate System for Forces and Moments .....................................................                        17 Figure 3: RO Nozzle and Safe End Geometry [20] ..........................................................                      17 File No.: 0801038.304                                                                                                                  Page 3 of 20 Revision: 1 F0306-01I


........................................................................................................
VStructural Integrity Associates, Inc.
19 APPENDIX A: ANSYS INPUT FILE: RON VY.INP .................................................
1.0 OBJECTIVE The objective of this calculation package is to establish the design inputs and methodology to be used for an ASME Code, Section III fatigue usage calculation of the reactor pressure vessel (RPV) recirculation outlet (RO) nozzle at Vermont Yankee Nuclear Power Station (VYNPS) 1 .
A-1 FileNo.: 0801038.304 Page 2 of 20 Revision:
This calculation, along with subsequent calculations for stress and fatigue, are being performed to assess the impact of using finite element analysis using all six components of stress in lieu of the Green's Function approach used in SI project VY-16Q [4, 7, and 11]. Therefore, to the extent possible, inputs from that project will be maintained and used.
1 F0306-01!
1.1     Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:
VStructural integrity Associates, Inc.List of Tables Table 1: Vessel and Nozzle/Safe End Transients
: a. Transient 9 described in Table 1 was changed to more precisely match the Green's Function analysis.
.............................................................
: b. All remaining changes marked throughout this calculation are editorial changes made to the text of the calculation package.
10 Table 2: H eat Transfer Coefficients
2.0 METHODOLOGY A detailed fatigue usage calculation of the RO nozzle will be performed using the methodology of Subarticle NB-3200 of Section III of the ASME Code [1]. The 1998 Edition includingthe 2000 Addenda of the ASME Code [10] is also used for material properties. Only the fatigue calculation portion of the ASME Code methodology will be used and the analysis will be a fatigue assessment only, not a complete ASME Code analysis.
.......................................................................................
Finite element analysis will be performed using a previously-developed axisymmetric finite element model (FEM) of the RO nozzle [7]. Thermal transient analysis will-be performed using the FEM for each defined transient. Concurrent with the thermal transients are pressure and piping interface loads; for these loads' unit load analyses (finite element analysis for pressure, and manual calculations for piping loads) will be performed. The stresses from these analyses will be scaled appropriately based on the magnitude of the pressure and piping loads during each thermal transient, and combined with stresses from the thermal transients. Other stress concentration factors (SCFs) will be applied as appropriate.
11 Table 3: Temperature-Dependent Material Properties
All six components of the stress tensor will be used for stress calculations. The stress components for the non-axisymmetric loads (shear and moment piping loads) can have opposite signs depending upon which side of the nozzle is being. examined. Therefore, when combining stress components from these loads with stress components from thermal transients and other loads, the signs of the stress components will be adjusted to maximize the magnitude of the stress component ranges. The fatigue analysis will be performed at locations that were determined in a previous calculation [4]. Stresses will be linearized at these locations.
...........................................................
11 Table 4: Recirculation Outlet Nozzle Attached Piping Loads and Dimensions
[9, 11] .........
14 Table 5: Membrane Plus Bending Stresses Due to Piping Loads ....................................
14 Table 6: 0% Flow Regions I and 3 Heat Transfer Coefficients
.......................................
15 Table 7: 0% Flow Region 5 Heat Transfer Coefficient
...................................................
16 List of Figures Figure 1: Nozzle and Vessel Wall Thermal Boundaries
...................................................
12 Figure 2: Coordinate System for Forces and Moments .....................................................
17 Figure 3: RO Nozzle and Safe End Geometry [20] ..........................................................
17 File No.: 0801038.304 Revision:
1 Page 3 of 20 F0306-01I VStructural Integrity Associates, Inc.1.0 OBJECTIVE The objective of this calculation package is to establish the design inputs and methodology to be used for an ASME Code, Section III fatigue usage calculation of the reactor pressure vessel (RPV) recirculation outlet (RO) nozzle at Vermont Yankee Nuclear Power Station (VYNPS)1.This calculation, along with subsequent calculations for stress and fatigue, are being performed to assess the impact of using finite element analysis using all six components of stress in lieu of the Green's Function approach used in SI project VY-16Q [4, 7, and 11]. Therefore, to the extent possible, inputs from that project will be maintained and used.1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:
: a. Transient 9 described in Table 1 was changed to more precisely match the Green's Function analysis.b. All remaining changes marked throughout this calculation are editorial changes made to the text of the calculation package.2.0 METHODOLOGY A detailed fatigue usage calculation of the RO nozzle will be performed using the methodology of Subarticle NB-3200 of Section III of the ASME Code [1]. The 1998 Edition includingthe 2000 Addenda of the ASME Code [10] is also used for material properties.
Only the fatigue calculation portion of the ASME Code methodology will be used and the analysis will be a fatigue assessment only, not a complete ASME Code analysis.Finite element analysis will be performed using a previously-developed axisymmetric finite element model (FEM) of the RO nozzle [7]. Thermal transient analysis will-be performed using the FEM for each defined transient.
Concurrent with the thermal transients are pressure and piping interface loads; for these loads' unit load analyses (finite element analysis for pressure, and manual calculations for piping loads) will be performed.
The stresses from these analyses will be scaled appropriately based on the magnitude of the pressure and piping loads during each thermal transient, and combined with stresses from the thermal transients.
Other stress concentration factors (SCFs) will be applied as appropriate.
All six components of the stress tensor will be used for stress calculations.
The stress components for the non-axisymmetric loads (shear and moment piping loads) can have opposite signs depending upon which side of the nozzle is being. examined.
Therefore, when combining stress components from these loads with stress components from thermal transients and other loads, the signs of the stress components will be adjusted to maximize the magnitude of the stress component ranges. The fatigue analysis will be performed at locations that were determined in a previous calculation
[4]. Stresses will be linearized at these locations.
The methodology described and applied herein and in the two additional recirculation outlet nozzle fatigue calculations is in accordance with the approach used in the SIA calculations for the feedwater nozzle [16, 17, 18] and contains no significantly different scientific or technical judgments used in those calculations.
The methodology described and applied herein and in the two additional recirculation outlet nozzle fatigue calculations is in accordance with the approach used in the SIA calculations for the feedwater nozzle [16, 17, 18] and contains no significantly different scientific or technical judgments used in those calculations.
File No.: 0801038.304 Page 4 of 20 Revision:
File No.: 0801038.304                                                                                               Page 4 of 20 Revision: 1 F0306-01:
1 F0306-01:
 
Structural Integrity Associates, Inc.The linearized primary plus secondary membrane plus bending stress will be used to determine the value of Ke to be used in the simplified elastic-plastic analysis in accordance with ASME Code NB-3200 methodology.
StructuralIntegrityAssociates, Inc.
Environmental fatigue multipliers will be applied in accordance with NUREG/CR-6583
The linearized primary plus secondary membrane plus bending stress will be used to determine the value of Ke to be used in the simplified elastic-plastic analysis in accordance with ASME Code NB-3200 methodology. Environmental fatigue multipliers will be applied in accordance with NUREG/CR-6583 [2]
[2]for the low alloy steel forging and NUREG/CR-5704
for the low alloy steel forging and NUREG/CR-5704 [15.] for the stainless steel safe end.
[15.] for the stainless steel safe end.3.0 ASSUMPTIONS  
3.0 ASSUMPTIONS / DESIGN INPUTS 3.1     Assumptions
/ DESIGN INPUTS 3.1 Assumptions
: 1. Extended power uprate (EPU) effects are considered as being applied to the entire 60-year period of operation. The higher pressures, flows, and temperatures at uprate conditions are used in determining and applying heat transfer coefficients [4, Section 3.2] [11, Section 4.1].
: 1. Extended power uprate (EPU) effects are considered as being applied to the entire 60-year period of operation.
: 2. The Boltup transientdoes not affect the RO nozzle because there is no pressure or temperature change, and the nozzle is sufficiently removed from the vicinity of the flange such that stresses due to head stud tensioning are insignificant at the nozzle location [8]. The Boltup transient is therefore excluded from the transients analyzed.
The higher pressures, flows, and temperatures at uprate conditions are used in determining and applying heat transfer coefficients
: 3. For the blend radius and safe end transient definitions, steady state condition time steps were assumed to be 5,000 seconds for Transients 3, 5, 6, 8, 9, and 40,000 seconds for Transients 1, 2, 4, 7, 10.
[4, Section 3.2] [11, Section 4.1].2. The Boltup transientdoes not affect the RO nozzle because there is no pressure or temperature change, and the nozzle is sufficiently removed from the vicinity of the flange such that stresses due to head stud tensioning are insignificant at the nozzle location [8]. The Boltup transient is therefore excluded from the transients analyzed.3. For the blend radius and safe end transient definitions, steady state condition time steps were assumed to be 5,000 seconds for Transients 3, 5, 6, 8, 9, and 40,000 seconds for Transients 1, 2, 4, 7, 10.4. The effect of non-uniform geometries is judged to be insignificant for flow inside the safe end, because of the smooth transition and small, geometry changes, as shown in Figure 3. The nominal inner diameter for all heat transfer regions was used to calculate heat transfer coefficients.
: 4. The effect of non-uniform geometries is judged to be insignificant for flow inside the safe end, because of the smooth transition and small, geometry changes, as shown in Figure 3. The nominal inner diameter for all heat transfer regions was used to calculate heat transfer coefficients.
: 5. Density, p, and Poisson's ratio, v, used in the FEM are assumed typical values of p = 0.283 lb/in 3 and v = 0.3, respectively.
: 5. Density, p, and Poisson's ratio, v, used in the FEM are assumed typical values of p = 0.283 lb/in 3 and v = 0.3, respectively.
: 6. For purposes of linearizing stress at the nozzle blend radius, the cladding is ignored'.7. Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 707F and the full values are reached at reactor design temperature, 575&deg;F, as was done in the previous analysis [11, Section 3.4].8. Consistent with Reference
: 6. For purposes of linearizing stress at the nozzle blend radius, the cladding is ignored'.
[4], 12% of the available temperature difference (AT) between the fluid and surface was assumed for all natural convection thermal heat transfer coefficients.
: 7. Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 707F and the full values are reached at reactor design temperature, 575&deg;F, as was done in the previous analysis [11, Section 3.4].
: 9. The instant temperature change for transients is assumed as a 1-second time step.3.
: 8. Consistent with Reference [4], 12% of the available temperature difference (AT) between the fluid and surface was assumed for all natural convection thermal heat transfer coefficients.
: 9. The instant temperature change for transients is assumed as a 1-second time step.
3.2    ASME Code Edition The analysis will be performed in a manner consistent with the fatigue usage rules in NB-3200 of Section III of the ASME Code; the 1998 Edition with Addenda through 2000 [1] will be used, for consistency with the previous analysis [11].
File No.: 0801038.304                                                                                  Page 5 of 20 Revision: 1 F0306-01I
 
VStructural integrity Associates, Inc.
3.3    Transients Previously developed thermal and pressure transients [11 Tables 2 and 3] are used for this analysis. The transients to be evaluated are shown in Table 1. For each transient,


==6.0 REFERENCES==
==6.0 REFERENCES==
: 1. American Society of Mechanical Engineers, Boiler and Pressure Vessel Code, Section III, Subsection NB, 1998 Edition, with Addenda through year 2000.2. NUREG/CR-6583 (ANL-97/18), "Effects of LWR Coolant Environments on Fatigue Design Curves of Carbon and Low-Alloy Steels," March 1998.3. J. P. Holman, "Heat Transfer," 5th Edition, McGraw Hill Inc.; 1981.4. Structural Integrity Associates Calculation No. VY-16Q-305, Revision 0, "Recirculation Outlet Stress History Development
: 1. American Society of Mechanical Engineers, Boiler and Pressure Vessel Code, Section III, Subsection NB, 1998 Edition, with Addenda through year 2000.
: 2. NUREG/CR-6583 (ANL-97/18), "Effects of LWR Coolant Environments on Fatigue Design Curves of Carbon and Low-Alloy Steels," March 1998.
: 3. J. P. Holman, "Heat Transfer," 5th Edition, McGraw Hill Inc.; 1981.
: 4. Structural Integrity Associates Calculation No. VY-16Q-305, Revision 0, "Recirculation Outlet Stress History Development for Nozzle Green Function."
: 5. CB&I, RPV Stress Report Sections S9 "Stress Analysis Recirculation Outlet Nozzle Vermont Yankee Reactor Vessel." and T9 "Thermal Analysis Recirculation Outlet Nozzle Vermont Yankee Reactor Vessel." CB&I Contract 9-620 1, SI File No. VY-16Q-204.
: 6. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.
: 7. Structural Integrity Associates Calculation No. VY-16Q-304, Revision 0, "Recirculation Outlet Nozzle Finite Element Model."
:
4.2 Thermal Transient Stress Analysis The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, file RONVY.INP], and is used as input to the files in which the thermal transient and pressure stress analyses are performed.
4.2 Thermal Transient Stress Analysis The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, file RONVY.INP], and is used as input to the files in which the thermal transient and pressure stress analyses are performed.
For the thermal transient ANSYS analyses, previously defined thermal transients
For the thermal transient ANSYS analyses, previously defined thermal transients [3, Table 1] are evaluated, applying heat transfer coefficients [3, Table 2], as appropriate, based on the flow rates for each individual transient.
[3, Table 1 ] are evaluated, applying heat transfer coefficients
[3, Table 2], as appropriate, based on the flow rates for each individual transient.
Each thermal transient is evaluated in ANSYS to determine the resulting temperature distributions.
Each thermal transient is evaluated in ANSYS to determine the resulting temperature distributions.
The thermal results are used as input for the stress analysis for each transient.
The thermal results are used as input for the stress analysis for each transient. The boundary FileNo.: 0801038.305                                                                                 Page 4 of 16 Revision: 1 F0306-O1RO
The boundary FileNo.: 0801038.305 Page 4 of 16 Revision:
 
1 F0306-O1RO Structural Integrity Associates, Inc.conditions used for the pressure load case were also applied to the thermal stress cases. Figure 2 and Figure 3 show the application of these boundary conditions.
StructuralIntegrityAssociates, Inc.
All ANSYS input files for the thermal analyses, as listed below, are saved in the project computer files: RON VYINP: Geometry and material properties VYRON TRAN]-T.INP, VYRONTRAN]-S.INP:
conditions used for the pressure load case were also applied to the thermal stress cases. Figure 2 and Figure 3 show the application of these boundary conditions.
Transient 1, thermal and stress analyses VYRONTRAN2-TINP, VY_RONTRAN2-S.INP:
All ANSYS input files for the thermal analyses, as listed below, are saved in the project computer files:
Transient 2, thermal and stress analyses VY_RON TRAN3-T.INP, VYRONTRAN3-S.INP:
RON VYINP: Geometry and material properties VYRON TRAN]-T.INP, VYRONTRAN]-S.INP: Transient 1, thermal and stress analyses VYRONTRAN2-TINP, VY_RONTRAN2-S.INP: Transient 2, thermal and stress analyses VY_RON TRAN3-T.INP, VYRONTRAN3-S.INP: Transient 3, thermal and stress analyses VYRONTRAN4-T.INP, VY RONTRAN4-S.INP: Transient 4, thermal and stress analyses VYRONTRAN5-T.INP, VYRONTRAN5-S.INP: Transient 5, thermal and stress analyses VY RON TRAN6-T.INP, VY RON TRAN6-S.INP: Transient 6, thermal and stress analyses VYRONTRAN7-T.INP, VYRONTRAN7-S.INP: Transient 7, thermal and stress analyses VYRONTRAN8-T.INP, VY RON TRAN8-S.INP: Transient 8, thermal and stress analyses VYRONTRAN9-TINP, VYRONTRAN9-S.INP: Transient 9, thermal and stress analyses VYRONTRANIO-T.INP, VY RON TRANIO-S.INP: Transient 10, thermal and stress analyses VYRON_TRAN]]-T.INP, VYRONTRAN1-US.INP: Transient 11, thermal and stress analyses VYRON_TRAN12-T.INP, VYRONTRAN12-S.INP: Transient 12, thermal and stress analyses 4.3 Determining Critical Stress Paths The thermal transient that is to be used in determining the critical stress path at the safe end was determined by the most severe temperature difference over the shortest amount of time. This transient, Transient 9, is intended to represent the worst case thermal transient. This occurs during the Improper Startup cycle per Reference [3, Table 1]. The thermal transient conditions are:
Transient 3, thermal and stress analyses VYRONTRAN4-T.INP, VY RONTRAN4-S.INP:
* 12% flow rate heat transfer coefficients.
Transient 4, thermal and stress analyses VYRONTRAN5-T.INP, VYRONTRAN5-S.INP:
Thermal shock from 526&deg;F to 130'F along the inside surface of the nozzle safe end and piping and a blend radius and lower vessel thermal shock from 526 0F to 2680 F.
Transient 5, thermal and stress analyses VY RON TRAN6-T.INP, VY RON TRAN6-S.INP:
* Constant temperatures from previous step for 26 seconds
Transient 6, thermal and stress analyses VYRONTRAN7-T.INP, VYRONTRAN7-S.INP:
* Thermal shock from 130'F to 526&deg;F along the inside surface of the nozzle safe end and piping and a blend radius and lower vessel thermal shock from 268'F to 526&deg;F.
Transient 7, thermal and stress analyses VYRONTRAN8-T.INP, VY RON TRAN8-S.INP:
* Steady state temperature conditions following thermal shocks.
Transient 8, thermal and stress analyses VYRONTRAN9-TINP, VYRONTRAN9-S.INP:
* Constant temperature of 120'F on the outside surface of the model.
Transient 9, thermal and stress analyses VYRONTRANIO-T.INP, VY RON TRANIO-S.INP:
The ANSYS input files for the analysis, as listed below, are saved in the project computer, files:
Transient 10, thermal and stress analyses VYRON_TRAN]]-T.INP, VYRONTRAN1-US.INP:
RONVYINP. Geometry and material properties VYRONTR4N9-T.INP, VYRONTRAN9-S.INP:                   Thermal and stress analysis for the worst case transient for the safe end An interactive review of the worst case thenral stress results (which are controlling for the safe end) showed the critical location in the model to be at Node 6395. The location of Node 6395 is shown in FileNo.: 0801038.305                                                                                 Page 5 of 16 Revision: 1 F0306-O1RO
Transient 11, thermal and stress analyses VYRON_TRAN12-T.INP, VYRONTRAN12-S.INP:
Transient 12, thermal and stress analyses 4.3 Determining Critical Stress Paths The thermal transient that is to be used in determining the critical stress path at the safe end was determined by the most severe temperature difference over the shortest amount of time. This transient, Transient 9, is intended to represent the worst case thermal transient.
This occurs during the Improper Startup cycle per Reference
[3, Table 1]. The thermal transient conditions are:* 12% flow rate heat transfer coefficients.
Thermal shock from 526&deg;F to 130'F along the inside surface of the nozzle safe end and piping and a blend radius and lower vessel thermal shock from 526 0 F to 268 0 F.* Constant temperatures from previous step for 26 seconds* Thermal shock from 130'F to 526&deg;F along the inside surface of the nozzle safe end and piping and a blend radius and lower vessel thermal shock from 268'F to 526&deg;F.* Steady state temperature conditions following thermal shocks.* Constant temperature of 120'F on the outside surface of the model.The ANSYS input files for the analysis, as listed below, are saved in the project computer, files: RONVYINP.
Geometry and material properties VYRONTR4N9-T.INP, VYRONTRAN9-S.INP:
Thermal and stress analysis for the worst case transient for the safe end An interactive review of the worst case thenral stress results (which are controlling for the safe end)showed the critical location in the model to be at Node 6395. The location of Node 6395 is shown in FileNo.: 0801038.305 Page 5 of 16 Revision:
1 F0306-O1RO Figure 4. This location was selected since it possessed the highest stress intensity during the worst case thermal transient.
This is the same location evaluated in Reference
[4].A critical stress location in the nozzle blend radius will also be analyzed.
This location is chosen based upon the highest pressure stress (which is controlling in the nozzle blend radius) in the base metal. An interactive review of the pressure stress intensity results showed the critical location in the nozzle blend radius to be at Node 3829 (Figure 5). This is the same location evaluated in Reference
[4].Figure 6 shows the two critical stress paths that will be used to extract the linearized stresses at the safe end and nozzle blend radius.4.4 Stress Calculation Linearized stresses from Node 6395 (safe end inside surface) and Node 3829 (nozzle blend radius inside surface of base metal) are used for the fatigue usage analysis, as shown in Figure 6. For the nozzle blend radius location, the stresses used are for the base metal only; since the cladding is of the integrally bonded type and is less than 10% of the total thickness of the section the material is unselected prior to stress extraction, per NB-3 122.3 [2].The pressure stress intensities for the safe end and blend radius paths were extracted using the ANSYS file VY/RONP.INP.
This produced one file, ROPRESSURE.lin, that contains results of the critical stress paths.Table 1 shows the final pressure stress intensity results for the safe end and blend radius. The results at the blend radius are slightly different from those reported in Table 2 of Reference
[4] as a result of the revised material properties (i.e., temperature dependent material properties were used in the current evaluation vs. constant material properties in Reference
[4]).Results were also extracted from the vessel portion of the model to verify the accuracy of the results obtained from the ANSYS model, and to check the results due to the use of the 2.0 multiplier on the vessel radius. These results are contained in the file RO PRESSURE.
lin. The radius of the finite element model (FEM) was multiplied by a factor of 2.0 [4] to account for the fact that the vessel portion of the axisymmetric model is a sphere, but the true geometry is the intersection of two cylinders.
The equation for the membrane hoop stress in a thin wall sphere is: 0 (pressure) x (radius))S 2 x th~ickes Considering an actual vessel base metal radius, R, of 105.906 inches increased by a factor of 2.0, a vessel base metal thickness, t, of 5.4375 inches, and an applied pressure, P, of 1,000 psi, the calculated stress for a thin wall sphere is PR/(2t) = 19,477 psi. This compares very well with the remote vessel wall membrane hoop stress from the ANSYS result file, ROPRESSURE.lin, of FileNo.: 0801038.305 Page 6 of 16 Revision:
1 F0306-O1 RO 18,070 psi. Thus, considering the peak total pressure stress of 31,270 psi, the stress concentrating effect of the nozzle blend radius is 31,270/19,477
= 1.61. In other words, the peak nozzle blend radius stress is 1.61 times higher than nominal vessel wall stress for the axisyimnetric model.The equation for the membrane hoop stress in a thin wall cylinder is: ((pressure) x (radius)k thickness j" Based on the previous dimensions, the calculated stress for a cylinder without the 2.0 factor is 19,477 psi. Increasing this by a factor of 1.61 yields an expected peak nozzle blend radius stress of 31,358 psi, which would be expected from a cylindrical geometry that is representative of the nozzle configuration.
Therefore, the result from the ANSYS file for the peak nozzle blend radius stress (31,270 psi) is close to the peak nozzle blend radius stress for a cylindrical geometry because of the use of the 2.0 multiplier.
This is consistent with SI's experience where a factor of two increase in radius is typical for representing the 3-D effect in an axisymmetric model.4.5 Piping Loads The piping loads were taken from Table 4 of Reference
[3]. To determine the piping load stresses, the distances from the applied piping loads to the limiting stress locations were first determined.
The limiting stress path locations from Section 4.3 are in the same locations assumed in Table 4 of Reference
[3]; this means that no reconciliation of the lengths in Table 4 of Reference
[3] is needed.Reference
[3, Section 4.1 ] methodology was used to calculate the piping load stresses.
The piping loads and piping load stresses are found in Table 4 and Table 5 of Reference
[3].Table 1: Pressure Stress Intensity Results (1,000 psi)Membrane plus Total Stress Location Bending Stress Intensity Intensity (psi)(psi)Safe End (Path 1 Inside) 11,350 11,490 Blend Radius (h2nd 30,540 31,270 (Path 2 Inside)FileNo.: 0801038.305 Page 7 of 16 Revision:
1 F0306-01RO 5.0 RESULTS OF ANALYSIS A thennal transient analysis for each defined transient, as well as unit pressure stress and piping interface load analyses were performed for the RO nozzle at Vermont Yankee. All six components of the stress tensor were extracted from the ANSYS model at the two limiting path locations, which are the same two locations previously evaluated
[4]. Table 2 provides the unit (1,000 psig) pressure stress analysis results. The unit pressure load results are used to choose the location to analyze at the* nozzle blend radius and will be scaled up or down based on applied pressures in the fatigue analysis.Table 5 of Reference
[3] provides the piping stresses at the two critical locations.
Table 3 shows an example of thermal stress results. The remaining thermal stress results are contained in the ANSYS output files, listed below, which are saved in the project computer files: ROPRESSURE.
lin: Unit pressure stress analysis results VYRONTRAN]-S.lin:
Transient 1, thermal stress analysis results VYRONTRAN2-S.lin:
Transient 2, thermal stress analysis results VYRON TRAN3-S.lin:
Transient 3, thermal stress analysis results VY RONTRAN4-S.lin:
Transient 4, thermal stress analysis results VYRONTRAN5-S.lin:
Transient 5, thermal stress analysis results VYRON TRAN6-S. lin: Transient 6, thermal stress analysis results VYRONTRAN7-S.
lin: Transient 7, thermal stress analysis results VYRONTRAN8-S.lin:
Transient 8, thermal stress analysis results VYRON TRAN9-S. lin: Transient 9, thermal stress analysis results, VYRONTRAN]O-S.lin:
Transient 10, thermal stress analysis results VYRONTRAN]1-S.lin:
Transient 11, thermal stress analysis results VYRONTRAN12-S.lin:
Transient 12, thermal stress analysis results A fatigue calculation using the methodology of Subarticle NB-3200 of Section III of the ASME Code [2] and an enviromnental fatigue usage analysis will be performed in a separate calculation package using the stress results from this calculation.
The results of this calculation are to be used in SI Calculation No. 081038.306, "Fatigue Analysis of Recirculation Outlet Nozzle." File No.: 0801038.305 Page 8 of 16 Revision:
1 F0306-O1RO  


==6.0 REFERENCES==
Figure 4. This location was selected since it possessed the highest stress intensity during the worst case thermal transient. This is the same location evaluated in Reference [4].
: 1. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.2. ASME Boiler and Pressure Vessel Code, Section III, Subsection NB, 1998 Edition with 2000 Addenda.3. SI Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Confirmatory Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle." 4. SI Calculation No. VY-16Q-305, Revision 0, "Recirculation Outlet Stress History Development for Nozzle Green Function." File No.: 0801038.305 Revision:
A critical stress location in the nozzle blend radius will also be analyzed. This location is chosen based upon the highest pressure stress (which is controlling in the nozzle blend radius) in the base metal. An interactive review of the pressure stress intensity results showed the critical location in the nozzle blend radius to be at Node 3829 (Figure 5). This is the same location evaluated in Reference [4].
1 Page 9 of 16 F0306-O1RO VStructural Integrity Associates, Inc.Table 2: Stresses Under Unit Pressure Load, psi Membrane plus Bending Total Node S Sz , S SY Syz Sx x SY Sz Sxy Syz Sxz SE 6395 -955.2 4420 10390 15.26 0 0 -955.2 4912 10530 -222.6 0 0 BR 3829 -718.7 -951.7 25000 4708 0 0 -718.7 206.2 30150 733.2 0 0 FileNo.: 0801038.305 Revision:
Figure 6 shows the two critical stress paths that will be used to extract the linearized stresses at the safe end and nozzle blend radius.
1 Page 10 of 16 F0306-01RO V Structural Integrity Associates, Inc.Table 3: Example Thermal Stress Result Output, psi Transient Node Time Membrane Plus Bending Total (s) Sx Sy Sz Sxy Syz Sxz Sx Sy Sz Sxy Syz Sxz 0 3379 196 351 0 0 3539 139 209 0 0 3 3367 207 351 0 0 3518 160 209 0 0 13 3340 231 350 0 0 3493 180 208 .0 0 233 180 11400. 12840 210 0 0 180 16290 17350 -536 0 0 2213 5983 -2660 293 0 0 7056 -3558 322 0 0 2393 149 8475 9884 164 0 0 149 12580 13670 -416 0 0 6773 4443 -1020 320 0 0 5018 -1463 256 0 0 7193 231 12680 13780 145 0 0 231 17340 18140 -588 0 0 6395 7493 10 -142 2054 221 0 0 10 164 2398 45 0 0 11093 3276 -654 256 0 0 3669 -954 192 0 0 16457 4080 -479 352 0 0 4491 -773 244 0 0 16517 3813 -231 351 0 0 4095 -404 230 0 0 16518 3689 -110 350 0 0 3383 297 199 0 0 17118 3241 307 349 0 0 3393 255 204 0 0 17119 3 -2918 623 348 0 0 3 -1521 2098 125 0 0 57120 3283 279 350 0 0 3439 223 206 0 0 0 3078 2100 4262 554 0 0 3078 4281 5859 577 0 0 3 3078 2100 4262 554 0 0 3078 4280 5856 577 0 0 13 3078 2099 4263 554 0 0 3078 4278 5853 576 0 0 233 823 6811 -8426 -847 0 0 823 12480 38540 5953 0 0 2213 3002 -447 2916 683 0 0 3002 1782 -3944 -735 0 0 2393 799 3298 -10540 -506 0 0 799 9988 25870 4515 0 0 6773 2953 -85 3049 980 0 0 2953 2409 -2931 -397 0 0 7193 1539 6354 -2971 49 0 0 1539 9542 24620 4575 0 0 3829 7493 1642 7294 6946 137 0 0 1642 6282 20660 2675 0 0 11093 2290 364 2825 500 0 0 2290 2225 882 -131 0 0 16457 3195 285 3758 754 0 0 3195 3045 526 -230 0 0 16517 3191 304 3705 753 0 0 3191 3131 687 -181 0 0 16518 3182 300 3699 752 0 0 3182 3120 680 -180 0 0 17118 3157 1120 3848 706 0 0 3157 3802 3273 233 0 0 17119 3127 1109 3832 704 0 0 3127 3771 3247 235 0 0 57120 3077 2085 4216 543 0 0 3077 4274 5877 573 0 0 Note: Not all time steps are listed in this table.File No.: 0801038.305 Revision:
4.4 Stress Calculation Linearized stresses from Node 6395 (safe end inside surface) and Node 3829 (nozzle blend radius inside surface of base metal) are used for the fatigue usage analysis, as shown in Figure 6. For the nozzle blend radius location, the stresses used are for the base metal only; since the cladding is of the integrally bonded type and is less than 10% of the total thickness of the section the material is unselected prior to stress extraction, per NB-3 122.3 [2].
1 Page 11 of 16 F0306-01RO U Structural Integrity Associates, Inc.1 -, ft WE PRES- NORM xw%11- &#xfd;Figure 1. RO Nozzle Internal Pressure Distribution File No.: 0801038.305 Revision:
The pressure stress intensities for the safe end and blend radius paths were extracted using the ANSYS file VY/RONP.INP. This produced one file, ROPRESSURE.lin, that contains results of the critical stress paths.
1 Page 12 of 16 F0306-OIRO Structural Integrity Associates, Inc........AN.........  
Table 1 shows the final pressure stress intensity results for the safe end and blend radius. The results at the blend radius are slightly different from those reported in Table 2 of Reference [4] as a result of the revised material properties (i.e., temperature dependent material properties were used in the current evaluation vs. constant material properties in Reference [4]).
... ................
Results were also extracted from the vessel portion of the model to verify the accuracy of the results obtained from the ANSYS model, and to check the results due to the use of the 2.0 multiplier on the vessel radius. These results are contained in the file RO PRESSURE.lin. The radius of the finite element model (FEM) was multiplied by a factor of 2.0 [4] to account for the fact that the vessel portion of the axisymmetric model is a sphere, but the true geometry is the intersection of two cylinders.
2...............
The equation for the membrane hoop stress in a thin wall sphere is:
..... ....... .... ............
0 (pressure)x (radius))
............
S 2 x th~ickes Considering an actual vessel base metal radius, R, of 105.906 inches increased by a factor of 2.0, a vessel base metal thickness, t, of 5.4375 inches, and an applied pressure, P, of 1,000 psi, the calculated stress for a thin wall sphere is PR/(2t) = 19,477 psi. This compares very well with the remote vessel wall membrane hoop stress from the ANSYS result file, ROPRESSURE.lin, of FileNo.: 0801038.305                                                                                  Page 6 of 16 Revision: 1 F0306-O1 RO
Figure 2. RO Nozzle Pressure Cap Load & Boundary Condition File No.: 0801038.305 Revision:
 
1 Page 13 of 16 F0306-01 RO Structural Integrity Associates, Inc.Figure 3. RO Nozzle Vessel Wall Boundary Condition FileNo.: 0801038.305 Page 14 of 16 Revision:
18,070 psi. Thus, considering the peak total pressure stress of 31,270 psi, the stress concentrating effect of the nozzle blend radius is 31,270/19,477 = 1.61. In other words, the peak nozzle blend radius stress is 1.61 times higher than nominal vessel wall stress for the axisyimnetric model.
1 F0306-O1RO V Structural Integrity Associates, Inc.I M ,y , = R-.-..;, -R.Figure 4. Safe End Critical Thermal Stress Intensity Location File No.: 0801038.305 Revision:
The equation for the membrane hoop stress in a thin wall cylinder is:
1 Page 15 of 16 F0306-O1RO Structural Integrity Associates, Inc.AM.N NODAL SOLUTION STEp=1.0114 (AVG~)DMV4~~9 S3P4'/4 Figure 5. Nozzle Blend Radius Limiting Pressure Stress Intensity Location Figure 6. Limiting Stress Paths File No.: 0801038.305 Revision:
(radius)
I Page 16 of 16 F0306-O1RO V Structural Integrity Associates, Inc. File No.: 0801038.306 CALCULATION PACKAGE Project No.: 0801038 Quality Program Z Nuclear E] Commercial PROJECT NAME: VY Confirmatory Analyses for CS and RO Nozzles CONTRACT NO.: 10163217 Amendment 5 CLIENT: PLANT: Entergy Nuclear Operations, Inc. Vermont Yankee Nuclear Power Station CALCULATION TITLE: Fatigue Analysis of Reactor Recirculation Outlet Nozzle D Project Manager Preparer(s)
((pressure)x k      thickness        j" Based on the previous dimensions, the calculated stress for a cylinder without the 2.0 factor is 19,477 psi. Increasing this by a factor of 1.61 yields an expected peak nozzle blend radius stress of 31,358 psi, which would be expected from a cylindrical geometry that is representative of the nozzle configuration. Therefore, the result from the ANSYS file for the peak nozzle blend radius stress (31,270 psi) is close to the peak nozzle blend radius stress for a cylindrical geometry because of the use of the 2.0 multiplier. This is consistent with SI's experience where a factor of two increase in radius is typical for representing the 3-D effect in an axisymmetric model.
&Document Affected Revision Description Approval Checker(s)
4.5 Piping Loads The piping loads were taken from Table 4 of Reference [3]. To determine the piping load stresses, the distances from the applied piping loads to the limiting stress locations were first determined. The limiting stress path locations from Section 4.3 are in the same locations assumed in Table 4 of Reference [3]; this means that no reconciliation of the lengths in Table 4 of Reference [3] is needed.
Revision Pages Signature
Reference [3, Section 4.1 ] methodology was used to calculate the piping load stresses. The piping loads and piping load stresses are found in Table 4 and Table 5 of Reference [3].
& Date Signatures
Table 1: Pressure Stress Intensity Results (1,000 psi)
& Date 01 -18 Initial issue.Gary L. Stevens Tyler Novotny Computer Files 01/07/09 01/07/09 Jennifer E. Smith 01/07/09 1 1-4,6-12, 14-19 Revised per summary ,/ Preparer: contained in Section 1.1. LL .'t44 P a Computer Files Changes are marked with"revision bars" in right- Gary L Stevens hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker: William F. Weitze 03/09/09 Page 1 of 19 F0306-OIRO Structural Integrity Associates, Inc.Table of Contents 1.0 O B JE C T IV E .................................................................................................................................
Membrane plus                    Total Stress Location                  Bending Stress                    Intensity Intensity                          (psi)
3 1.1 Changes Made in Revision I of this Calculation
(psi)
...........................................................
Safe End 11,350                          11,490 (Path 1 Inside)
3 2.0 M ETH OD OLO G Y ..............................................................................................................
Blend (h2nd Radius (Path 2 Inside)                  30,540                          31,270 FileNo.: 0801038.305                                                                                Page 7 of 16 Revision: 1 F0306-01RO
3 3.0 D E SIG N IN PU T S .........................................................................................................................
 
4 3.1 Stress C alculation
5.0     RESULTS OF ANALYSIS A thennal transient analysis for each defined transient, as well as unit pressure stress and piping interface load analyses were performed for the RO nozzle at Vermont Yankee. All six components of the stress tensor were extracted from the ANSYS model at the two limiting path locations, which are the same two locations previously evaluated [4]. Table 2 provides the unit (1,000 psig) pressure stress analysis results. The unit pressure load results are used to choose the location to analyze at the
..........................................................................................................
      *nozzle blend radius and will be scaled up or down based on applied pressures in the fatigue analysis.
4 3.2 Fatigue Usage Analysis, General ...................................................................................
Table 5 of Reference [3] provides the piping stresses at the two critical locations. Table 3 shows an example of thermal stress results. The remaining thermal stress results are contained in the ANSYS output files, listed below, which are saved in the project computer files:
4 3.3 Event Cycles, V ESLFA T ..............................................................................................
ROPRESSURE.lin: Unit pressure stress analysis results VYRONTRAN]-S.lin: Transient 1, thermal stress analysis results VYRONTRAN2-S.lin: Transient 2, thermal stress analysis results VYRON TRAN3-S.lin: Transient 3, thermal stress analysis results VY RONTRAN4-S.lin: Transient 4, thermal stress analysis results VYRONTRAN5-S.lin: Transient 5, thermal stress analysis results VYRON TRAN6-S. lin: Transient 6, thermal stress analysis results VYRONTRAN7-S. lin: Transient 7, thermal stress analysis results VYRONTRAN8-S.lin: Transient 8, thermal stress analysis results VYRON TRAN9-S. lin: Transient 9, thermal stress analysis results, VYRONTRAN]O-S.lin: Transient 10, thermal stress analysis results VYRONTRAN]1-S.lin: Transient 11, thermal stress analysis results VYRONTRAN12-S.lin: Transient 12, thermal stress analysis results A fatigue calculation using the methodology of Subarticle NB-3200 of Section III of the ASME Code [2] and an enviromnental fatigue usage analysis will be performed in a separate calculation package using the stress results from this calculation.
5 3.4 Material Properties, VESLFAT ......................................
The results of this calculation are to be used in SI Calculation No. 081038.306, "Fatigue Analysis of Recirculation Outlet Nozzle."
5 3.5 Stress Indices ..............................................................................................................  
File No.: 0801038.305                                                                              Page 8 of 16 Revision: 1 F0306-O1RO
&#xfd;6 4.0 C A L C U L A T IO N S .........................................................................................................................
 
6 5.0 RESULTS OF AN A LY SIS .....................................................................................................
==6.0     REFERENCES==
7  
: 1. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.
: 2. ASME Boiler and Pressure Vessel Code, Section III, Subsection NB, 1998 Edition with 2000 Addenda.
: 3. SI Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Confirmatory Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle."
: 4. SI Calculation No. VY-16Q-305, Revision 0, "Recirculation Outlet Stress History Development for Nozzle Green Function."
File No.: 0801038.305                                                                      Page 9 of 16 Revision: 1 F0306-O1RO
 
VStructural IntegrityAssociates, Inc.
Table 2: Stresses Under Unit Pressure Load, psi Membrane plus Bending                          Total Node    S      Sz,    S      SY  Syz Sx      x    SY      Sz      Sxy    Syz Sxz SE  6395  -955.2  4420  10390  15.26  0  0  -955.2 4912  10530  -222.6    0  0 BR  3829  -718.7  -951.7  25000  4708  0  0  -718.7 206.2  30150    733.2    0  0 FileNo.: 0801038.305                                                                    Page 10 of 16 Revision: 1 F0306-01RO
 
V StructuralIntegrityAssociates, Inc.
Table 3: Example Thermal Stress Result Output, psi Total Transient Node    Time                Membrane Plus Bending (s)    Sx      Sy        Sz      Sxy  Syz Sxz  Sx  Sy    Sz      Sxy Syz Sxz 0      -33    -3379      196    351    0  0  3539  139      209  0  0 3      -33    -3367      207      351    0  0  3518  160      209  0  0 13    -33    -3340      231      350    0  0  3493  180      208 .0  0 233    180    11400. 12840    210    0  0  180 16290 17350    -536  0  0 2213    -74    -5983    -2660    293    0  0  7056 -3558      322  0  0 2393    149      8475    9884      164  0  0  149 12580 13670    -416  0  0 6773    -51    -4443    -1020    320    0  0  5018 -1463      256  0  0 7193    231    12680    13780    145    0  0  231 17340 18140    -588  0  0 6395    7493      10      -142    2054      221    0  0    10  164  2398      45  0  0 11093    -40    -3276      -654    256    0  0  3669  -954      192  0  0 16457    -47    -4080      -479    352    0  0  4491  -773      244  0  0 16517    -41    -3813      -231    351    0  0  4095  -404      230  0  0 16518    -28    -3689      -110    350    0  0  3383  297      199  0  0 17118    -33    -3241      307      349    0  0  3393  255      204  0  0 17119      3    -2918      623      348    0  0    3 -1521  2098      125  0  0 57120    -33    -3283      279      350    0  0  3439  223      206  0  0 0    3078    2100      4262      554    0  0  3078  4281  5859      577  0  0 3    3078    2100      4262      554    0  0  3078  4280  5856      577  0  0 13    3078    2099      4263      554    0  0  3078  4278  5853      576  0  0 233    823    6811      -8426    -847  0  0  823 12480 38540    5953  0  0 2213    3002      -447    2916      683    0  0  3002  1782 -3944    -735  0  0 2393    799    3298    -10540    -506  0  0  799  9988 25870    4515  0  0 6773    2953      -85    3049      980    0  0  2953  2409 -2931    -397  0  0 7193    1539      6354    -2971      49    0  0  1539  9542 24620    4575  0  0 3829 7493    1642    7294      6946      137  0  0  1642  6282 20660    2675  0  0 11093  2290      364    2825      500    0  0  2290  2225  882    -131  0  0 16457  3195      285      3758      754    0  0  3195  3045  526    -230  0  0 16517  3191      304    3705      753    0  0  3191  3131  687    -181  0  0 16518  3182      300      3699    752    0  0  3182  3120  680    -180  0  0 17118  3157      1120      3848    706    0  0  3157  3802  3273      233  0  0 17119  3127      1109      3832    704    0  0  3127  3771  3247      235  0  0 57120  3077      2085    4216      543    0  0  3077  4274  5877      573  0  0 Note: Not all time steps are listed in this table.
File No.: 0801038.305                                                                                      Page 11 of 16 Revision: 1 F0306-01RO
 
U    StructuralIntegrity Associates, Inc.
1-,                                                                        ft WE PRES- NORM xw%
11-        &#xfd; Figure 1. RO Nozzle Internal Pressure Distribution File No.: 0801038.305                                                          Page 12 of 16 Revision: 1 F0306-OIRO
 
StructuralIntegrityAssociates, Inc.
      .......                                                                                                                       AN
                                                                  .......... 2...............
                                                                              ..           ................ ..... ........ ... . .......................
Figure 2. RO Nozzle Pressure Cap Load & Boundary Condition File No.: 0801038.305                                                                                          Page 13 of 16 Revision: 1 F0306-01 RO
 
StructuralIntegrityAssociates, Inc.
Figure 3. RO Nozzle Vessel Wall Boundary Condition FileNo.: 0801038.305                                                      Page 14 of 16 Revision: 1 F0306-O1RO
 
V    StructuralIntegrityAssociates, Inc.
I M ,y , = R-.-..;, -R.
Figure 4. Safe End Critical Thermal Stress Intensity Location File No.: 0801038.305                                                                      Page 15 of 16 Revision: 1 F0306-O1RO
 
StructuralIntegrity Associates, Inc.
NODAL SOLUTION                                                        AM.N STEp=1
              .0114    (AVG~)
DMV4~~9 S3P4
                      '/4 Figure 5. Nozzle Blend Radius Limiting Pressure Stress Intensity Location Figure 6. Limiting Stress Paths File No.: 0801038.305                                                                    Page 16 of 16 Revision: I F0306-O1RO
 
V StructuralIntegrityAssociates, Inc.                       File No.: 0801038.306 CALCULATION PACKAGE                                  Project No.: 0801038 Quality Program Z Nuclear    E] Commercial PROJECT NAME:
VY Confirmatory Analyses for CS and RO Nozzles CONTRACT NO.:
10163217 Amendment 5 CLIENT:                                              PLANT:
Entergy Nuclear Operations, Inc.                 Vermont Yankee Nuclear Power Station CALCULATION TITLE:
Fatigue Analysis of Reactor Recirculation Outlet Nozzle D                Project Manager            Preparer(s) &
Document      Affected        Revision Description              Approval                Checker(s)
Revision        Pages                                        Signature & Date        Signatures & Date 01            - 18              Initial issue.
Gary L. Stevens          Tyler Novotny Computer Files                                        01/07/09                  01/07/09 Jennifer E. Smith 01/07/09 1      1-4,6-12, 14-19    Revised per summary        ,/                      Preparer:
contained in Section 1.1.
LL                  .'t44  P    a Computer Files  Changes are marked with "revision bars" in right-      Gary L Stevens hand margin.                 03/09/09            Tyler D. Novotny 03/09/09 Checker:
William F. Weitze 03/09/09 Page 1 of 19 F0306-OIRO
 
StructuralIntegrity Associates, Inc.
Table of Contents 1.0  O B JEC TIVE .................................................................................................................................       3 1.1    Changes Made in Revision I of this Calculation ...........................................................                                     3 2.0  M ETH OD OLO G Y ..............................................................................................................                       3 3.0  D ESIG N IN PU TS .........................................................................................................................         4 3.1    Stress C alculation ..........................................................................................................                 4 3.2    Fatigue Usage Analysis, General ...................................................................................                           4 3.3    Event Cycles, VESLFA T ..............................................................................................                           5 3.4    Material Properties, VESLFAT ......................................                                                                            5 3.5      Stress Indices ..............................................................................................................                &#xfd;6 4.0  C A L C U L A TION S .........................................................................................................................      6 5.0  RESULTS OF AN ALY SIS .....................................................................................................                          7
 
==6.0  CONCLUSION==
S AND DISCUSSIONS ...............................................................................                                          7 7.0  R EFER EN C ES .............................................................................................................................          8 List of Tables Table  1: Safe End Load Sets as Input to VESLFAT .......................................................................                                  9 Table  2: Nozzle Blend Radius Load Sets as Input to VESLFAT .......................                                                                      I1......
Table  3: Temperature-Dependent Material Properties for VESLFAT (3)                                                    ............................ 12 Table  4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves .........................................                                            13 Table  5: Pressure and Attached Piping Unit Load Case Stress Components ................................                                                14 Table  6: Fatigue Usage Calculation for the Safe End .................................                                                                  15 Table 7: Fatigue Usage Calculation for the Nozzle Blend Radius .................................................                                          16 Table 8: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location .......................                                                      17 Table 9: Linearized Stress Files Compiled for VY-RO-StressResults.xls ......................................                                              19 File No.: 0801038.306                                                                                                                                      Page 2 of 19 Revision: 1 F0306-01RO
 
VStructural IntegrityAssociates, Inc.
1.0      OBJECTIVE The objective of this calculation package is to perform an ASME Code, Section III fatigue usage evaluation and a plant-specific evaluation of reactor water environmental effects for the reactor pressure vessel (RPV) recirculation outlet (RO) nozzle at the Vermont Yankee Nuclear Power Station.
1.1    Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:
: a. Editorial changes were made to Table 1 to more precisely describe the transient load sets.
: b. All but one of the changes made to Table 2 were editorial to more precisely describe the portions of the transients. The one non-editorial change was to move a time split in Transient 9 to better catch a stress peak or stress valley.
: c. Table 3 and the corresponding VESLFAT input file were revised to reflect actual material properties for the safe end. Revision 0 of this calculation tabulated SA-1 82 F304 (18Cr -8Ni) properties, but actually used properties for an Alloy 600 material.
: d. Table 5 was changed to eliminate the application ofKt = 1.53 to the nozzle corner piping loads.
: e. Tables 6, 7, and 8 were revised to reflect the new fatigue usage and environmental assisted fatigue summaries as a result of the changes associated with Bullets b and c above.
: f. Table 8 was revised for editorial changes.
: g. The results of various sensitivity studies on fatigue usage were added to Section 5.0.
: h. Revision of CUF values in Sections 5.0 and 6.0 to reflect revised analyses.
: i. All remaining changes marked throughout this calculation are editorial changes made to the text of the calculation package.
2.0      METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package
[2]. Based on that methodology, thermal stresses, pressure stresses, and attached piping load stresses were developed in the Reference [1 ] calculation for use in this fatigue calculation. The thermal stresses are added to pressure stresses and attached piping load stresses'. Both the pressure and piping load stresses are scaled based on the magnitudes of the pressure and nozzle fluid temperature during each transient. All six components of the stress tensor from the stress results are used in the fatigue calculation.
Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 70'F and the full values are reached at a reactor design temperature of 575'F [2, Assumption 3.1.7]. In addition, design seismic and deadweight loads are also included and scaled in combination with the thermal loads for each transient. This combination, coupled with assigning the stress due to these loads the same sign as the thermal stress, is considered to be a very conservative treatment of the loads overall in that deadweight and design seismic loads are considered and scaled for every transient.
File No.: 0801038.306                                                                                                    Page 3 of 19 Revision: 1 F0306-01RO
 
StructuralIntegrity Associates, Inc.
The fatigue calculation is performed for both the limiting safe end and nozzle blend radius locations, as determined in the Reference [1] calculation, and uses the methodology of Subarticle NB-3200 of Section III of the ASME Code [3]. An environmental fatigue usage analysis is also performed in this calculation applying the methodology and associated environmental fatigue multipliers described in Reference [6].
3.0      DESIGN INPUTS 3.1 Stress Calculation Linearized stress components at Node 6395 (limiting safe end path at inside surface) and Node 3829 (limiting nozzle blend radius path at inside surface) are used for the fatigue usage calculation, as shown in Figure 6 of Reference [1]. For the nozzle blend radius location, the stresses used in the evaluation are for the base metal only; that is, the cladding material is unselected prior to stress extraction. The stress components from the thermal stress analyses are combined with stress components due to pressure and piping loads. The linearized thermal stress components for each transient are taken from the relevant output files in the Reference [1] calculation (a sample of which was provided in Table 3 of Reference [1]). The unit pressure stress component results are taken from Table 2 of Reference [1]. Piping load stress components are taken from Table 5 of the Reference [2] calculation.
3.2 Fatigue Usage Analysis, General Structural Integrity's VESLFAT program [4] is used to perform the fatigue usage calculation in accordance with the fatigue usage portion of ASME Code, Section III, Subarticle NB-3200 [3].
VESLFAT performs the analysis required by NB-3222.4(e) [3] for Service Levels A and B conditions defined by the user. The VESLFAT program computes the primary-plus-secondary and total stress ranges for all events and performs a correction for elastic-plastic analysis, if necessary.
The program computes the stress intensity range based on the stress component ranges for all event pairs [3, NB-3216.2]. The program evaluates the stress ranges for primary-plus-secondary and primary-plus-secondary-plus-peak stresses based on all six components of stress (3 normal and 3 shear stresses). If the primary-plus-secondary stress intensity range is greater than 3 Sm, the total stress range must be increased by the simplified elastic-plastic strain correction factor, Ke, as described in NB-3228.5 [3]. The design stress intensity, Sm, is specified as a function of temperature. The input maximum temperature for both states of a load set pair is used to establish the S,, value used in the fatigue calculations from the user-defined input values.
When more than one stress set is defined for either of the event pair loadings, the stress differences are determined for all of the potential stress pairs, and the pair producing the largest alternating total stress intensity (Salt), including any effects of Ke, is used. The principal stresses for the stress ranges are determined by solving for the roots of the following cubic equation2:
S3 _ (Tx    -+- yY+ O-z)S2 + (C3x Cy -+ C7 a, z + a,-7    - ,y2    _ Sxz2 _ Syz2)s 2Note that cy., ay, az, etc. are used synonymously with Sx, S,, S,, etc., in this calculation.
File No.: 0801038.306                                                                                      Page 4 of 19 Revision: 1 F0306-OIRO


==6.0 CONCLUSION==
VStructural IntegrityAssociates, Inc.
S AND DISCUSSIONS
                      - (Cy"Gy a, + 2 rxy Tz "*yz - CTz Ty2 _ *y , 2 _ Cx TyZ2 o The stress intensities for the event pairs are reordered in decreasing order of Sait, including a correction for the ratio of modulus of elasticity (E) from the fatigue curve divided by E from the material evaluated at the maximum event temperature. This allows a fatigue table to be created to eliminate the number of cycles available for each of the transient events. This fatigue table is based on a worst-case progressive pairing of events in order of the most severe alternating stress to the least severe, allowing determination of a bounding fatigue usage per NB-3222.4(e) [3]. For each load set pair in the fatigue table, the allowable number of cycles is determined based on Salt.
...............................................................................
3.3     Event Cycles, VESLFAT For the Vermont Yankee RO nozzle analysis, transients that consist of combined stress peaks or valleys are split so that each successive peak or valley is treated separately. Therefore, there are 61 load sets based on the combined stress changes for the safe end, and 46 load sets based on the combined stress changes for the nozzle blend radius location. The reason the number of load sets are not equal for each path is because the time history stress results of those paths differ. Tables 1 and 2 show the load sets applicable to plant operation, with cycle counts per Table I of Reference [2].
7 7.0 R E FE R E N C E S .............................................................................................................................
These are used as input to VESLFAT for the safe end and nozzle blend radius locations, respectively. The cycle counts of Reference [2, 7] consider 60 years of operation. The data from Table 1 is entered into the VESLFAT input files VY-RO-VFAT-1i.CYC (safe end) and the data from Table 2 is entered into the file VY-RO- VFAT-21. CYC (nozzle blend radius).
8 List of Tables Table 1: Safe End Load Sets as Input to VESLFAT .......................................................................
3.4     Material Properties, VESLFAT Material properties are entered in VESLFAT input files VY-RO-VFAT-]I.FDT (safe end) and VY-RO-VFAT-2I.FDT (nozzle blend radius). Table 3 lists the temperature-dependent material properties used in the analysis [5]. Table 4 lists the fatigue curve for the nozzle blend radius and safe end materials
9 Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT .......................
[3, Appendix I, Table 1-9.1 and Figure 1-9.1 (UTS < 80.0 ksi) for the nozzle blend radius, and Tables 1-9.1 and 1-9.2.2 (Curve C) and Figures 1-9.2.1 and 1-9.2.2 for the safe end location]. Curve C is selected for the safe end location because it is the most conservative curve among the three extended curves for austenitic steel. VESLFAT automatically scales the stresses by the ratio of E on the fatigue curve to E in the analysis, for the purposes of determining allowable numbers of cycles, as required by the ASME Code.
1...... I Table 3: Temperature-Dependent Material Properties for VESLFAT (3) ............................
Other material properties are input as follows:
12 Table 4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves .........................................
m = 1.7, n = 0.3, parameters used to calculate Ke for the safe end location [3, Table NB-3228.5(b)-1]
13 Table 5: Pressure and Attached Piping Unit Load Case Stress Components
................................
14 Table 6: Fatigue Usage Calculation for the Safe End .................................
15 Table 7: Fatigue Usage Calculation for the Nozzle Blend Radius .................................................
16 Table 8: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location .......................
17 Table 9: Linearized Stress Files Compiled for VY-RO-StressResults.xls
......................................
19 File No.: 0801038.306 Page 2 of 19 Revision:
1 F0306-01RO VStructural Integrity Associates, Inc.1.0 OBJECTIVE The objective of this calculation package is to perform an ASME Code, Section III fatigue usage evaluation and a plant-specific evaluation of reactor water environmental effects for the reactor pressure vessel (RPV) recirculation outlet (RO) nozzle at the Vermont Yankee Nuclear Power Station.1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:
: a. Editorial changes were made to Table 1 to more precisely describe the transient load sets.b. All but one of the changes made to Table 2 were editorial to more precisely describe the portions of the transients.
The one non-editorial change was to move a time split in Transient 9 to better catch a stress peak or stress valley.c. Table 3 and the corresponding VESLFAT input file were revised to reflect actual material properties for the safe end. Revision 0 of this calculation tabulated SA-1 82 F304 (18Cr -8Ni)properties, but actually used properties for an Alloy 600 material.d. Table 5 was changed to eliminate the application ofKt = 1.53 to the nozzle corner piping loads.e. Tables 6, 7, and 8 were revised to reflect the new fatigue usage and environmental assisted fatigue summaries as a result of the changes associated with Bullets b and c above.f. Table 8 was revised for editorial changes.g. The results of various sensitivity studies on fatigue usage were added to Section 5.0.h. Revision of CUF values in Sections 5.0 and 6.0 to reflect revised analyses.i. All remaining changes marked throughout this calculation are editorial changes made to the text of the calculation package.2.0 METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package[2]. Based on that methodology, thermal stresses, pressure stresses, and attached piping load stresses were developed in the Reference
[1 ] calculation for use in this fatigue calculation.
The thermal stresses are added to pressure stresses and attached piping load stresses'.
Both the pressure and piping load stresses are scaled based on the magnitudes of the pressure and nozzle fluid temperature during each transient.
All six components of the stress tensor from the stress results are used in the fatigue calculation.
Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 70'F and the full values are reached at a reactor design temperature of 575'F [2, Assumption 3.1.7]. In addition, design seismic and deadweight loads are also included and scaled in combination with the thermal loads for each transient.
This combination, coupled with assigning the stress due to these loads the same sign as the thermal stress, is considered to be a very conservative treatment of the loads overall in that deadweight and design seismic loads are considered and scaled for every transient.
File No.: 0801038.306 Page 3 of 19 Revision:
1 F0306-01RO Structural Integrity Associates, Inc.The fatigue calculation is performed for both the limiting safe end and nozzle blend radius locations, as determined in the Reference
[1] calculation, and uses the methodology of Subarticle NB-3200 of Section III of the ASME Code [3]. An environmental fatigue usage analysis is also performed in this calculation applying the methodology and associated environmental fatigue multipliers described in Reference
[6].3.0 DESIGN INPUTS 3.1 Stress Calculation Linearized stress components at Node 6395 (limiting safe end path at inside surface) and Node 3829 (limiting nozzle blend radius path at inside surface) are used for the fatigue usage calculation, as shown in Figure 6 of Reference
[1]. For the nozzle blend radius location, the stresses used in the evaluation are for the base metal only; that is, the cladding material is unselected prior to stress extraction.
The stress components from the thermal stress analyses are combined with stress components due to pressure and piping loads. The linearized thermal stress components for each transient are taken from the relevant output files in the Reference
[1] calculation (a sample of which was provided in Table 3 of Reference
[1]). The unit pressure stress component results are taken from Table 2 of Reference
[1]. Piping load stress components are taken from Table 5 of the Reference
[2] calculation.
3.2 Fatigue Usage Analysis, General Structural Integrity's VESLFAT program [4] is used to perform the fatigue usage calculation in accordance with the fatigue usage portion of ASME Code, Section III, Subarticle NB-3200 [3].VESLFAT performs the analysis required by NB-3222.4(e)
[3] for Service Levels A and B conditions defined by the user. The VESLFAT program computes the primary-plus-secondary and total stress ranges for all events and performs a correction for elastic-plastic analysis, if necessary.
The program computes the stress intensity range based on the stress component ranges for all event pairs [3, NB-3216.2].
The program evaluates the stress ranges for primary-plus-secondary and primary-plus-secondary-plus-peak stresses based on all six components of stress (3 normal and 3 shear stresses).
If the primary-plus-secondary stress intensity range is greater than 3 Sm, the total stress range must be increased by the simplified elastic-plastic strain correction factor, Ke, as described in NB-3228.5
[3]. The design stress intensity, Sm, is specified as a function of temperature.
The input maximum temperature for both states of a load set pair is used to establish the S,, value used in the fatigue calculations from the user-defined input values.When more than one stress set is defined for either of the event pair loadings, the stress differences are determined for all of the potential stress pairs, and the pair producing the largest alternating total stress intensity (Salt), including any effects of Ke, is used. The principal stresses for the stress ranges are determined by solving for the roots of the following cubic equation2:
S3 _ (Tx -+- y Y+ O-z)S2 + (C3x Cy -+ C7 z a, + a,-7 -,y2 _ Sxz2 _ Syz2)s 2 Note that cy., ay, az, etc. are used synonymously with Sx, S,, S,, etc., in this calculation.
File No.: 0801038.306 Page 4 of 19 Revision:
1 F0306-OIRO VStructural Integrity Associates, Inc.-(Cy" Gy a, + 2 rxy Tz -CTz Ty2 _ , 2 _ Cx TyZ2 o The stress intensities for the event pairs are reordered in decreasing order of Sait, including a correction for the ratio of modulus of elasticity (E) from the fatigue curve divided by E from the material evaluated at the maximum event temperature.
This allows a fatigue table to be created to eliminate the number of cycles available for each of the transient events. This fatigue table is based on a worst-case progressive pairing of events in order of the most severe alternating stress to the least severe, allowing determination of a bounding fatigue usage per NB-3222.4(e)
[3]. For each load set pair in the fatigue table, the allowable number of cycles is determined based on Salt.3.3 Event Cycles, VESLFAT For the Vermont Yankee RO nozzle analysis, transients that consist of combined stress peaks or valleys are split so that each successive peak or valley is treated separately.
Therefore, there are 61 load sets based on the combined stress changes for the safe end, and 46 load sets based on the combined stress changes for the nozzle blend radius location.
The reason the number of load sets are not equal for each path is because the time history stress results of those paths differ. Tables 1 and 2 show the load sets applicable to plant operation, with cycle counts per Table I of Reference
[2].These are used as input to VESLFAT for the safe end and nozzle blend radius locations, respectively.
The cycle counts of Reference
[2, 7] consider 60 years of operation.
The data from Table 1 is entered into the VESLFAT input files VY-RO-VFAT-1i.CYC (safe end) and the data from Table 2 is entered into the file VY-RO- VFAT-21. CYC (nozzle blend radius).3.4 Material Properties, VESLFAT Material properties are entered in VESLFAT input files VY-RO-VFAT-]I.FDT (safe end) and VY-RO-VFAT-2I.FDT (nozzle blend radius). Table 3 lists the temperature-dependent material properties used in the analysis [5]. Table 4 lists the fatigue curve for the nozzle blend radius and safe end materials[3, Appendix I, Table 1-9.1 and Figure 1-9.1 (UTS < 80.0 ksi) for the nozzle blend radius, and Tables 1-9.1 and 1-9.2.2 (Curve C) and Figures 1-9.2.1 and 1-9.2.2 for the safe end location].
Curve C is selected for the safe end location because it is the most conservative curve among the three extended curves for austenitic steel. VESLFAT automatically scales the stresses by the ratio of E on the fatigue curve to E in the analysis, for the purposes of determining allowable numbers of cycles, as required by the ASME Code.Other material properties are input as follows: m = 1.7, n = 0.3, parameters used to calculate Ke for the safe end location [3, Table NB-3228.5(b)-1]
m = 2.0, n = 0.2, parameters used to calculate Ke for the nozzle blend radius location [3, Table NB-3228.5(b)-1]
m = 2.0, n = 0.2, parameters used to calculate Ke for the nozzle blend radius location [3, Table NB-3228.5(b)-1]
E from fatigue curve = 28,300 ksi [3, Appendix 1, Figure 1-9.2] for the safe end location.E from fatigue curve = 30,000 ksi [3, Appendix I, Figure 1-9.1] for the nozzle blend radius location.File No.: 0801038.306 Page 5 of 19 Revision:
E from fatigue curve = 28,300 ksi [3, Appendix 1, Figure 1-9.2] for the safe end location.
1 F0306-OIRO Structural Integrity Associates, Inc.3.5 Stress Indices The limiting stress path for the RO nozzle safe end is defined in Reference
E from fatigue curve = 30,000 ksi [3, Appendix I, Figure 1-9.1] for the nozzle blend radius location.
[1]. The stresses caused by the piping were hand calculated and do require a stress concentration factor, if appropriate.
File No.: 0801038.306                                                                                   Page 5 of 19 Revision: 1 F0306-OIRO
The stress concentration factor for the safe end location is 1.53 [2, Section 3.8]. This value is conservatively used for both the C 2 and K 2 values required by the ASME Code [3, NB-3600].
The piping loads are relatively minor in comparison to the other loads this nozzle experiences so the conservative C 2 and K 2 values will have a small impact on the analysis.
Table 5 shows the piping loads after applying the C 2 and K 2 values as appropriate.
4.0 CALCULATIONS Table 5 contains the stress components at the locations of interest for the 1,000 psi unit pressure stress case [1, Table 2]. Table 5 also contains the stress components for the attached piping load unit stress case [2, Table 5], which correspond to a reactor design temperature of 575&deg;F [2, Section 3.1.7].The attached piping load stress components were applied assuming the same signs as the thermal stress, which yields the largest stress component ranges.The calculations of all of the VESLFAT stress inputs are automated in Excel workbooks VY-RO-VFAT-li.xls (safe end) and VY-RO-VFAT-2i.xls (nozzle blend radius). These files are organized with sheets labeled as follows:* Overview:
Contains general information.
* Other Stresses:
Contains pressure and attached piping load stresses.
As shown in Table 5, the pressure stresses use the membrane-plus-bending and total stress from the finite element analysis [1].* Rearranger:
There are 12 Rearranger sheets, one for each thermal transient as analyzed by ANSYS. In these sheets, thermal stresses are copied from Excel workbook VY-RO-StressResults.xls, and rearranged to conform to VESLFAT input format (including switching the shear stress components Sx, and Sy, as required by VESLFAT).
VY-RO-StressResults.xls contains the results of the ANSYS stress linearization for each transient.
The files contained within this workbook are shown in Table 9. Time-varying scale factors for the attached piping loads (based on path metal temperature) and pressure are determined, and used to scale the unit load case stresses, which are then added to the thermal stresses.
Since the attached piping loads can act in any direction, the stresses due to the attached piping loads are assigned the same sign as the thermal stresses to maximize the component stresses.Algebraic summation of all six stress components is performed for pressure, piping loads, and thermal stresses at each transient time step. The VESLFAT stress input also includes time-varying metal temperature, as obtained from the ANSYS output, which is used to determine temperature-dependent properties from the values in Table 3.* VESLFAT: Contains the VESLFAT stress input, as obtained from the Rearranger sheets.Load set numbers are entered on this sheet, as defined in Table 1 and Table 2. These sheets are saved to VESLFAT input files VY-RO-VFAT-li.STR (safe end) and VY-RO-VFAT-2i.STR (nozzle blend radius).File No.: 0801038.306 Page 6 of 19 Revision:
I F0306-O1RO Structural Integrity Associates, Inc.5.0 RESULTS OF ANALYSIS Table 6 and Table 7 provide the detailed calculated 60-year fatigue usage, as obtained from VESLFAT output files VY-RO-VFAT-11.FAT (safe end) and VY-RO-VFAT-2LFAT (nozzle blend radius). All VESLFAT input and output files are saved in the project computer files associated with this calculation.
From Table 6, the safe end cumulative usage factor (CUF) is 0.00308 for 60 years. From Table 7, the nozzle blend radius CUF is 0.0 175 for 60 years.From Table 1 of Reference
[6], it was determined that hydrogen water chemistry (HWC) is available for 47% of the total 60-year operating period, and normal water chemistry (NWC) is present for the remaining 53% of the total 60-year operating period. From Table 1 of Reference
[6], the dissolved oxygen values for the recirculation line (which is applicable to the RO nozzle) are 48 ppb for HWC conditions and 122 ppb for NWC conditions.
For the stainless steel piping, the environmental fatigue factors for post-HWC and pre-HWC are 15.35 and 8.36 from Table 2 of Reference
[6]. The overall environmental multiplier is found by (15.35 x 47% + 8.36 x 53%), which equals 11.645, conservatively rounded upto 11.7. Therefore, the overall environmental multiplier is 11.7, which results in an EAF adjusted CUF of 11.7 x 0.00308 0.0360 for 60 years, which is acceptable (i.e., less than the allowable value of 1.0).Based on the detailed CUF calculation shown in Table 7, a detailed EAF adjusted CUF evaluation on a load-pair basis is provided for the nozzle blend radius location in Table 8. The EAF usage from Table 8 is 0.111 for 60 years, which is less than the allowable value of 1.0 and is therefore acceptable.
The effective overall Fen is 0.111/0.0175
= 6.32.As a part of fatigue analysis calculations, it was noted that using Fy = -20 kips in the piping loads caused a slightly higher total stress intensity.
However, the change was determined to have an insignificant effect on fatigue usage results. In addition, the effect of modeling the distinct material properties of both Type F304 and Type F316 in the ANSYS analysis (as opposed to using 18Cr-8Ni properties) was determined to have an insignificant effect on fatigue usage results. Finally, the effect of applying a minimum temperature of 130'F for thermal boundary Region 2 (see Figure 1 of Reference
[2]) was determined to have an insignificant effect on fatigue usage results. These investigations and associated results are contained in the project files.


==6.0 CONCLUSION==
StructuralIntegrityAssociates, Inc.
S AND DISCUSSIONS Detailed fatigue calculations for the Vermont Yankee RO nozzle were performed based on the results of stress analyses previously performed
3.5    Stress Indices The limiting stress path for the RO nozzle safe end is defined in Reference [1]. The stresses caused by the piping were hand calculated and do require a stress concentration factor, if appropriate. The stress concentration factor for the safe end location is 1.53 [2, Section 3.8]. This value is conservatively used for both the C2 and K2 values required by the ASME Code [3, NB-3600]. The piping loads are relatively minor in comparison to the other loads this nozzle experiences so the conservative C2 and K2 values will have a small impact on the analysis. Table 5 shows the piping loads after applying the C2 and K2 values as appropriate.
[1]. The thermal stresses were combined with stresses due to pressure and attached piping loads, both of which were scaled based on the magnitudes of the pressure and metal temperature during each thermal transient.
4.0      CALCULATIONS Table 5 contains the stress components at the locations of interest for the 1,000 psi unit pressure stress case [1, Table 2]. Table 5 also contains the stress components for the attached piping load unit stress case [2, Table 5], which correspond to a reactor design temperature of 575&deg;F [2, Section 3.1.7].
All six components of the stress tensor were used for the fatigue calculations.
The attached piping load stress components were applied assuming the same signs as the thermal stress, which yields the largest stress component ranges.
The fatigue calculations were performed at previously-determined limiting locations in the safe end and nozzle blend radius, and used the methodology of Subarticle NB-3200 of Section III of the ASME Code [3].File No.: 0801038.306 Page 7 of 19 Revision:
The calculations of all of the VESLFAT stress inputs are automated in Excel workbooks VY-RO-VFAT-li.xls (safe end) and VY-RO-VFAT-2i.xls (nozzle blend radius). These files are organized with sheets labeled as follows:
1 F0306-O1RO Structural Integrity Associates, Inc.The 60-year CUT for the safe end location was'determined to be 0.00308 and the CUF for the nozzle blend radius location was determined to be 0.0175. Both values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.
* Overview: Contains general information.
Detailed EAF assessments were also performed for the two RO nozzle locations.
* Other Stresses: Contains pressure and attached piping load stresses. As shown in Table 5, the pressure stresses use the membrane-plus-bending and total stress from the finite element analysis [1].
The 60-year EAF CUF for the safe end location was determined to be 0.0360. The 60-year EAF CUF for the nozzle blend radius location was determined to be 0.111 using temperature-dependent Fen multipliers for each load pair. Both values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.
* Rearranger: There are 12 Rearranger sheets, one for each thermal transient as analyzed by ANSYS. In these sheets, thermal stresses are copied from Excel workbook VY-RO-StressResults.xls, and rearranged to conform to VESLFAT input format (including switching the shear stress components Sx, and Sy, as required by VESLFAT). VY-RO-StressResults.xls contains the results of the ANSYS stress linearization for each transient. The files contained within this workbook are shown in Table 9. Time-varying scale factors for the attached piping loads (based on path metal temperature) and pressure are determined, and used to scale the unit load case stresses, which are then added to the thermal stresses. Since the attached piping loads can act in any direction, the stresses due to the attached piping loads are assigned the same sign as the thermal stresses to maximize the component stresses.
Algebraic summation of all six stress components is performed for pressure, piping loads, and thermal stresses at each transient time step. The VESLFAT stress input also includes time-varying metal temperature, as obtained from the ANSYS output, which is used to determine temperature-dependent properties from the values in Table 3.
* VESLFAT: Contains the VESLFAT stress input, as obtained from the Rearranger sheets.
Load set numbers are entered on this sheet, as defined in Table 1 and Table 2. These sheets are saved to VESLFAT input files VY-RO-VFAT-li.STR (safe end) and VY-RO-VFAT-2i.STR (nozzle blend radius).
File No.: 0801038.306                                                                                    Page 6 of 19 Revision: I F0306-O1RO


==7.0 REFERENCES==
StructuralIntegrity Associates, Inc.
: 1. Structural Integrity Associates Calculation No. 0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle." 2. Structural Integrity Associates Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle." 3. ASME Boiler and Pressure Vessel Code, Section III, 1998 Edition with 2000 Addenda.4. VESLFAT, Version 1.42, 02/06/07, Structural Integrity Associates.
5.0      RESULTS OF ANALYSIS Table 6 and Table 7 provide the detailed calculated 60-year fatigue usage, as obtained from VESLFAT output files VY-RO-VFAT-11.FAT (safe end) and VY-RO-VFAT-2LFAT (nozzle blend radius). All VESLFAT input and output files are saved in the project computer files associated with this calculation.
: 5. ASME Boiler and Pressure Vessel Code, Section II, Part D-Properties, 1998 Edition with 2000 Addenda.6. SI Calculation No. VY-16Q-303, Revision 0, "Environmental Fatigue Evaluation of Reactor Recirculation Inlet Nozzle and Vessel Shell/Bottom Head." 7. Entergy Design Input Record (DIR) EC No. 1773, DIR. Revision 1, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY-1 6Q-209.8. Deleted (not used in this calculation).
From Table 6, the safe end cumulative usage factor (CUF) is 0.00308 for 60 years. From Table 7, the nozzle blend radius CUF is 0.0 175 for 60 years.
File No.: 0801038.306 Revision:
From Table 1 of Reference [6], it was determined that hydrogen water chemistry (HWC) is available for 47% of the total 60-year operating period, and normal water chemistry (NWC) is present for the remaining 53% of the total 60-year operating period. From Table 1 of Reference [6], the dissolved oxygen values for the recirculation line (which is applicable to the RO nozzle) are 48 ppb for HWC conditions and 122 ppb for NWC conditions.
1 Page 8 of 19 F0306-OIRO Structural Integrity Associates, Inc.Table 1: Safe End Load Sets as Input to VESLFAT VESLFAT Load Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Start Transient ties Time, see lTrnl 0 2Tml 1616.4 1Tm2 0 2Trn2_ 0.4 3Trn2 301 4Trn2_ 601.4 1 Trn3 0 2Trn3 250 3Tm3_ 2050 4Tm3_ 2960 5Trn3_ 5560 lTrn4_ 0 2Trn4 2 3Trn4_ 7 4Tm4_ 46 5Tn4_ 992 6Tin4 2294 7Trn4_ 3050 8Trn4_ 6899 9Trn4 7745 1OTm4_ 8645 11Trn4_ 11057 12Tin4 16166 13Tm4_ 16818 14Trn4 17118 1 Tn5_ 0 2Trn5 1.5 3Trn5 24 4Trn5 2310 5Trn5 2611 6Trn5 2911.4 1Trn6 0 2Trn6 0.6 3Trn6 20 4Trn6_ 2312 5Tm6_ 2613 Temp Change Pressure Change Up Up Down Down Down Down Up Up Down Up & Down Down None None Down Down & Up Up & Down Down & Up Up & Down Down & Up Up Up Up Up & Down None Down None None Up Down None Down None None Up Down None Down Up Up None None None None None None None None None Up Up & Down Down None Down Down & Up Up & Down Down Down Down Up Up None None Up Up & Down Down & Up None None None Up Up & Down Down & Up None None None Cycles 300 300 300 300 300 300 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 60 60 60 60 60 60 1 1 1 37 6Tin6 2913.6 File No.: 0801038.306 Revision:
For the stainless steel piping, the environmental fatigue factors for post-HWC and pre-HWC are 15.35 and 8.36 from Table 2 of Reference [6]. The overall environmental multiplier is found by (15.35 x 47% + 8.36 x 53%), which equals 11.645, conservatively rounded upto 11.7. Therefore, the overall environmental multiplier is 11.7, which results in an EAF adjusted CUF of 11.7 x 0.00308 0.0360 for 60 years, which is acceptable (i.e., less than the allowable value of 1.0).
I Page 9 of 19 F0306-O1RO VStructural Integrity Associates, Inc.Table 1 (continued):
Based on the detailed CUF calculation shown in Table 7, a detailed EAF adjusted CUF evaluation on a load-pair basis is provided for the nozzle blend radius location in Table 8. The EAF usage from Table 8 is 0.111 for 60 years, which is less than the allowable value of 1.0 and is therefore acceptable. The effective overall Fen is 0.111/0.0175 = 6.32.
Safe End Load Sets as Input to VESLFAT VESLFAT Load Set 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 Start Transient ties Time, see lTmn7 0 2Trn7 37.5 3Trn7 600 4Trn7 4443 1Trn8 0 2Tm8_ 3 3Trn8_ 2295 4Trn8 3927 1Trn9 0 2Trn9 0.12 3Trn9 27.92 4Trn9 290.15 1TmlO_ 0 2Trnm0 730.8 3TmlO_ 6314 4Tm 10 6844 5TrnlO 9555 6TrnlO 14937 1Trnl 1 0 2Tml 1- 0 3Trnl 1 0 1Trnl2 0 2Trnl2 0 3Trnl2 0 Temp Change Pressure Change Cycles Down Down Down Down None Up Down None Down Down & Up Up None Down Down Down Down Down Down None None None None None None Down Down Down Down Down Down & Up None None None None None None Down Down Down Down Down Down None Up Down None Up Down 228 228 228 228 300 300 300 300 300 300 120 120 120 1 1 10 File No.: 0801038.306 Revision:
As a part of fatigue analysis calculations, it was noted that using Fy = -20 kips in the piping loads caused a slightly higher total stress intensity. However, the change was determined to have an insignificant effect on fatigue usage results. In addition, the effect of modeling the distinct material properties of both Type F304 and Type F316 in the ANSYS analysis (as opposed to using 18Cr-8Ni properties) was determined to have an insignificant effect on fatigue usage results. Finally, the effect of applying a minimum temperature of 130'F for thermal boundary Region 2 (see Figure 1 of Reference [2]) was determined to have an insignificant effect on fatigue usage results. These investigations and associated results are contained in the project files.
1 Page 10 of 19 F0306-0IRO V Structural Integrity Associates, Inc.Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT VESLFAT Load Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Start Transient Time, sec 1Tml 0 2Tml 808.2 1Trn2 0 2Trn2_ 0.4 3Trn2_ 401 1Trn3_ 0 2Trn3 250 3Trn3 2325 4Trn3_ 3510 5Trn3_ 5060 1Trn4_ 0 2Trn4_ 2 3Trn4_ 7 4Trn4_ 46 5Trn4_ 1091 6Trn4_ 2348 7Trn4_ 3269 8Tm4_ 6983 9Trn4_ 7745 1OTrn4_ 13839 l1Trn4_ 16918 12Tn4_ 18986 1 Tn5_ 0 2Tn5_ 24 3Trn5_ 2611 1Trn6_ 0 2Tm6_ 0.6 3Trn6_ 20 4Trn6_ 2663 lTrn7 0 2Trn7_ 37.5 3Trn7_ 2247 1 Trn8 0 Temp Change Pressure Change Cycles Up Up Down Down Down Up Up & Down Down & Up Up & Down Down None None Down Down & Up Up & Down Down & Up Up & Down Down & Up Up Up & Down Down None None Up & Down Down None None Up & Down Down Down Down Down None Up Up None None None None None None None None Up Up & Down Down None Down Down & Up Up & Down Down Down & Up Up None None Up & Down Down & Up None Up Up & Down Down & Up None Down Down Down Down 300 300 300 300 300 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 60 60 60 1 1 228 File No.: 0801038.306 Revision:
 
1 Page 11 of 19 F0306-0IRO Structural Integrity Associates, Inc.Table 2 (continued):
==6.0     CONCLUSION==
Nozzle Blend Radius Load Sets as Input to VESLFAT VESLFAT Load Set Transient Start Time, sec Temp Change Pressure Change Cycles 34 35 36 37 38 39 40 41 42 43 44 45 46 2Trn8_3Trn8_1Trn9_2Trn9_3Trn9_1 Trnl 0 I1Tml0I 2Tml0 1 Trnl 1 3Trnll 1Trnl2 2Trnl2_3Trnl2_3 2025 0 9 58 0 313.2 0 0 0 0 0 0 Up & Down Down Down Up None Down Down None None None None None None Down & Up None None None None Down Down None Up Down None Up Down 228 228 1 1 1 300 300 120 120 120 1 1 1 Table 3: Temperature-Dependent Material Properties for VESLFAT (3)Material SA-508 Class 2 (nozzle blend radius(2))
S AND DISCUSSIONS Detailed fatigue calculations for the Vermont Yankee RO nozzle were performed based on the results of stress analyses previously performed [1]. The thermal stresses were combined with stresses due to pressure and attached piping loads, both of which were scaled based on the magnitudes of the pressure and metal temperature during each thermal transient. All six components of the stress tensor were used for the fatigue calculations. The fatigue calculations were performed at previously-determined limiting locations in the safe end and nozzle blend radius, and used the methodology of Subarticle NB-3200 of Section III of the ASME Code [3].
T, 'F 70 200 300 400 500 600 70 200 300 400 500 600 E x 106, psi 27.8 27.1 26.7 26.1 25.7 25.2 28.3 27.6 27.0 26.5 25.8 25.3 S., ksi 26.7 26.7 26.7 26.7 26.7 26.7 20 20 20 19.3 18.0 17.0 Sy, ksi 50.0 47.0 45.5 44.2 43.2 42.1 30 25.9 23.4 21.4 20.0 18.9 SA-182 F316 (Safe End (1))Notes: 1. For the safe end material, SA-182 F316 (16Cr- 12Ni- 2Mo) austenitic stainless steel properties are used.2. For the nozzle blend radius material, SA508 Class 2 material properties are used (3/4Ni-1/2Mo-1/3Cr-V), per Reference
File No.: 0801038.306                                                                                    Page 7 of 19 Revision: 1 F0306-O1RO
[2].3. All values are taken from Reference
 
[5].4. SA-508 Class 2 in the Code of Construction is the same as SA-508 Gr. 2 Class 2 in the 1998 ASME Code [5].File No.: 0801038.306 Revision:
StructuralIntegrity Associates, Inc.
I Page 12 of 19 F0306-0IRO Structural Integrity Associates, Inc.Table 4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves Sa, ksi Sa, ksi Number of Cycles Carbon/Low Alloy (1) Austenitic 10 20 50 100 200 500 1000 2000 5000 10000 20000 50000 100000 200000 500000 1000000 2.E+06 5.E+06 1.E+07 2.E+07 5.E+07 1.E+08 1.E+09 1.E+10 1.E+1I 580 410 275 205 155 105 83 64 48 38 31 23 20 16.5 13.5 12.5 N/A N/A N/A N/A N/A N/A N/A N/A N/A 708 512 345 261 201 148 119 97 76 64 55.5 46.3 40.8 35.9 31 28.2 22.8(2)18.4(2)16.4(2)15.2(2)]4.3 (2)14.1(2)13.9(2)13.7(2)13.6(2)Note: 1.2.Using UTS _ 80 ksi curve.Using Curve C for austenitic steel.File No.: 0801038.306 Revision:
The 60-year CUT for the safe end location was'determined to be 0.00308 and the CUF for the nozzle blend radius location was determined to be 0.0175. Both values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.
1 Page 13 of 19 F0306-OIRO VStructural Integrity Associates, Inc.Table 5: Pressure and Attached Piping Unit Load Case Stress Components Node Membrane plus Bending (1) Total (1)d(2) SY S S, yz S" SY. S z Sx Sxz t 5) SyZ t 5)Pressure (3) 6395 -955.2 4420 10390 15.26 0 0 -955.2 4912 10530 -222.6 0 0 3829 -718.7 -951.7 25000 4708 0 0 -718.7 206.2 30150 733.2 0 0 ping(4) 6395 0 7930 0 831 2066 0 0 12133 0 1271 3160 0 3829 0 218 0 42 49 0 0 218 0 42 49 0 Nuotes: I.2.3.4.5.All stress values are in uILts o psI.The safe end location is represented by Node 6395, and the nozzle blend radius location is represented by Node 3829.The stresses for both nodes represent the stress due to an applied pressure of 1,000 psig.Piping stresses for both locations represent the stress due to full attached piping loads at an RPV temperature of 575'F.Syz and S_ components have been rearranged from the ANSYS output in order to be in correct order for VESLFAT.File No.: 0801038.306 Revision:
Detailed EAF assessments were also performed for the two RO nozzle locations. The 60-year EAF CUF for the safe end location was determined to be 0.0360. The 60-year EAF CUF for the nozzle blend radius location was determined to be 0.111 using temperature-dependent Fen multipliers for each load pair. Both values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.
1 Page 14 of 19 F0306-0IRO Structural Integrity Associates, Inc.Table 6: Fatigue Usage Calculation for the Safe End Load Desc. Load Desc. Salt#a #1 #2 #2 n (cycles) Sn (psi) Ke Si) Nallow U#1 #1 #2 #2 (psi)47 2Trn9 48 3Trn9_ 1 79715 2.62 169777 331.52 0.00302 15 4Trn4_ 49 4Trn9_ 1 30275 1 23722 1757500 0.00000 15 4Trn4_ 28 3Trn5 9 29755 1 23610 1784800 0.00001 19 8Trn4 28 3Trn5 10 26926 1 21352 2647400 0.00000 17 6Trn4_ 28 3Trn5_ 10 25213 1 20492 3155800 0.00000 28 3Trn5_ 39 2Trn7_ 1 20321 1 16926 8269400 0.00000 18 7Trn4 28 3Trn5_ 10 19961 1 16731 8866300 0.00000 28 3Trn5 44 3Trn8_ 20 4606 1 16450 9819700 0.00000 34 3Trn6_ 44 3Trn8 1 4606 1 16450 9819700 0.00000 43 2Trn8_ 44 3Trn8_ 207 4606 1 16450 9819700 0.00002 6 4Trn2_ 43 2Trn8_ 21 4028 1 16176 11335000 0.00000 6 4Trn2_ 35 4Trn6_ 1 3519 1 15752 14441000 0.00000 6 4Trn2 29 4Trn5 60 3484 1 15637 15446000 0.00000 6 4Trn2_ 22 11Trn4_ 10 11783 1 15613 15666000 0.00000 6 4Trn2_ 23 12Trn4_ 10 3202 1 15588 15895000 0.00000 2 2Trnl_ 6 4Trn2_ 198 3193 1 15583 15936000 0.00001 2 2Trnl 31 6Trn5 60 3319 1 15531 16430000 0.00000 2 2Trnl 37 6Trn6 1 3319 1 15531 16430000 0.00000 2 2Trnl1 25 14Trn4_ 10 1702 1 15055 23098000 0.00000 2 2Trnl_ 40 3Trn7_ 1 18894 1 14987 24732000 0.00000 2 2Trnl_ 16 5Trn4_ 10 5069 1 14487 41157000 0.00000 33 2Trn6 52 3Trnl_0 1 12380 1 14460 42317000 0.00000 13 2Trn4 52 3Trnl0 10 10470 1 13875 1.336E+09 0.00000 50 1Trnl0_ 52 3Trnl0_ 289 9634 1 13841 1.968E+09 0.00000 50 1TrnlO 53 4Trnl0 11 18796 1 13770 4.465E+09 0.00000 3 1Trn2 53 4Trnl0 289 18795 1 13769 4.491E+09 0.00000 Total 0.00308 Usage =Note: All other load pairs have an alternating stress, Saft, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.File No.: 0801038.306 Page 15 of 19 Revision:
 
I F0306-O1RO V Structural Integrity Associates, Inc.Table 7: Fatigue Usage Calculation for the Nozzle Blend Radius Load Desc. Load Desc. n Salt#1 #1 #2 #2 (cycles) S (psi) Ke (psi)2 2 1 1 2 1 2 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 4 4 4 10 35 35 9 7 7 7 3 3 31 1Trnl1 14 4Trn4_1Trnl_ 37 2Trn9_1Trn1_ 16 6Trn4_1Trnl_ 27 2Trn6_2Trnl_ 45 2Trn12_1Trnl_ 15 5Trn4_lTrnl_ 18 8Trn4_1Trnl_ 36 1Trn9_1Trn1_ 13 3Trn4_1Trnl_ 38 3Trn9_1Trn1_ 12 2Trn4_1Trnl_ 23 1Trn5_1Trn1_ 17 7Trn4_1Trnl_ 5 3Trn2_2Trnl_ 5 3Trn2_2Trnl_ 28 3Trn6_2Trn 1 11 1Trn4_2Trnl1 26 1Trn6_2Trnl_ 25 3Trn5_2Trnl1 29 4Trn6_2Trnl1 8 3Trn3_2Trnl_ 4 2Trn2_2Trn2_ 41 1Trn 11 2Trn2_ 32 3Trn7_2Trn2_ 40 2Trn 10_5Trn3_ 40 2Trn 10_3Trn8_ 40 2Trn 10_3Trn8_ 43 3Trnl 1_4Trn3_ 43 3Trn 11_2Trn3_ 46 3Trn12_2Trn3_ 44 1Trn12_2Trn3_ 43 3Trn 11 1Trn2_ 43 3Trn 11_1Trn2_ 19 9Trn4_2Trn7_ 42 2Trnl I 10 1 10 1 1 10 10 1 10 1 10 60 10 166 134 1 10 1 68 1 10 82 120 1 97 10 193 35 10 1 1 8 67 10 1 21902 1.00 43085 21390 1.00 32177 15100 1.00 31137 42381 1.00 27020 45773 1.00 26852 18457 1.00 26707 13066 1.00 26562 28617 1.00 24546 34179 1.00 24042 25904 1.00 23939 36762 1.00 23612 35051 1.00 22617 22210 1.00 22533 29847 1.00 22312 29301 1.00 22309 33856 1.00 22227 33460 1.00 21959 32908 1.00 21661 29068 1.00 21226 29068 1.00 21226 29847 1.00 21214 30245 1.00 21092 32229 1.00 20851 30983 1.00 20125 30982 1.00 20124 31344 1.00 20033 29931 1.00 19888 29651 1.00 19696 30915 1.00 19357 30523 1.00 19349 30523 1.00 19349 30523 1.00 19349 31236 1.00 19331 23810 1.00 16958 27376 1.00 11515 Nallow U 6889 0.0015 17617 0.0001 19701 0.0005 30496 0.0000 31084 0.0000 31604 0.0003 32139 0.0003 40947 0.0000 43643 0.0002 44218 0.0000 46129 0.0002 54348 0.0011 55358 0.0002 58126 0.0029 58168 0.0023 59234 0.0000 62919 0.0002 67330 0.0000 74454 0.0008 74454 0.0000 74661 0.0001 76819 0.0011 81328 0.0015 96967 0.0000 96981 0.0010 99198 0.0001 102050 0.0019 105678 0.0003 112494 0.0001 112655 0.0000 112655 0.0000 112655 0.0001 113042 0.0006 181219 0.0001 infinite 0.0000 Total 0.0175 Usage =Note: All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.File No.: 0801038.306 Revision:
==7.0    REFERENCES==
1 Page 16 of 19 F0306-O1RO Structural Integrity Associates, Inc.Table 8: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location VY RO flozzle Corner Environmental Fatique Calculation CUF Calculation from file NrY-RO-VFAT-2i.fat:
: 1. Structural Integrity Associates Calculation No. 0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle."
Index Load.#1: Description#1 1 (cycles)(5 Load#21Description#2':n2Icycles)(5) (cycles) (5: Sr,(pi) K S.(psi) 1`.1 U S I Trn_ 300 14 i 4Trn4_ 4 10 10 21902 1.00 43085 6889 0.0015 2 1 Trn1_ 290 3r 2Trn9 1 1 21390 1.00 32177 17617 0.0001 3 1 1Trnl I 289 16 i 6Trn4_ 10 10 15100 1.00 31137 19701 0.0005 4 1 lTrnl 279 27 2Trn6 i 1 1 42381 1.00 .27020 30496 0.0000 5 2 27rnl 30G 451 2Trn 12 1 45773 1.00 26852 31054 0.0000 6 1 l 1Trnl_ -78 18 s 5Trn_4 i 10 10 18457 1.00 26707 31604 0,0003 7 1 1Trnt 268 18 i 8Trn4_ i 10 10 13066 1.00 26562 32139 0.0003 8 1n 125nl L8 36 1Trn9 1 1 28617 1.00 24546 40947 0.0000 9 '1 lTrn i 257 13 3Trn 4- 10 10 34179 1.00 24042 43643 0.0002 10 1i 1Trnl_ 247 38 3Trn 9_ 1 1 25904 1.00 23939 44218 0.0000 11 1 Trl 246 12 1 2Trn4 10 10 36762 1.00 23,612 46129 0.0002 12 1 2 Trnl 23 I1Trn5_ i 60 60 35051 1.00 22617 4348 0.0011 13 1 ITrnl 176 17 7Trn_ 10 10 22210 1.00 22533 55358 0.0002 14 1 ITrnl 16,6 3Trn2 300 166 29847 1.00 22312 58126 0.0029 15 :2 2Trnl 299 5 3Trn2 134 134 29301 1.00 22309 E5168 0.0023 16 2 27rnl 165 28 3Trn6 1 1 33856 1.00 22227 59234 0.0000 17 2 .2Trnl 1 1S4 11 1Trn4 1 10 10 33460 1.00 21959 62919 0.0002 18 2 2Trnl 1 26 1 rn6 1 1 32908 1.00 21661 67330 0.0000 19 2 2Trnl 1 153 25 3TrnS 60 60 29068 1.00 21226 74454 0.0008 20 2 2T rn i 93 29 dTrn6_ 1 1 29068 1.00 21226 74454 0.0000 21 2 27rnl R2 8 i 3Trn3 10 10 29847 1.00 21214 74661 0.0001 22 2 2Trnl 82 4 2Trn2 300 82 30245 1.00 21092 76819 0.001.1 23 4 2rn2_ m 218 41 1 1Trn11- 1 120 120
: 2. Structural Integrity Associates Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle."
* 32229 1.00 20851 81328 0.0015 24 4 2Trn2 98 32 3Trn7 1 1 30983 1.00 20125 06967 0.0000 25 .4 2Trn2 Q7 40 1 2Trnl10- O 300 97 30082 1.00 20124 n- 1 0.0010 26 10 5Trn3 10 do 2Trn10_ i 203 10 31344 1.00 20033 99198 0.0001 27 35 7 mTrn 228 40 2 Trn 10 193 193 29931 1.00 19589 102050 0.0019 28 35- 3Trn_ 35 43 3Trnh1 120 35 29651 1.00 19698 105678 0.0003 29 9 4Trn3 10 43 3 Trn11 1 85 10 30915 1.00 19357 112494 0.0001 30 7 2Trn3 10 4  3Trn12 i 1 1 30523 1.00 19349 112655 0.0000 31 7 2Trn3 9 44 1Trn12i 1 1 30523 1.00 19349 112655 0.0000 32 7 2Trn3 8 43 J3Trnl1 75 8 30523 1.00 19349 112655 0.0001 33 3 lTrn2 300 43 3Trn11 67 67 31236 1.00 19331 113042 0.0006 34 3 tTrn2 233 19 9Trn4 i 10 10 23810 1.00 16958 181219 0.0001 35 , 31 2Tmn_ 1 42 2T1rn1_ 1 120 1. 27376 1.00 11515 infinte 0.0000 Total, U = 0.0175 File No.: 0801038.306 Revision:
: 3. ASME Boiler and Pressure Vessel Code, Section III, 1998 Edition with 2000 Addenda.
1 Page 17 of 19 F0306-O1RO Structural Integrity Associates, Inc.Table 8 (continued):
: 4. VESLFAT, Version 1.42, 02/06/07, Structural Integrity Associates.
EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location EAF Calcuatina IIWC DO rIlVLC 00 ndW8~,"uskumTh I.'4.r~/FI 48 122 ppb% HWC = 47% 53% =% IIWc Transient Maximum Temperatures:
: 5. ASME Boiler and Pressure Vessel Code, Section II, Part D-Properties, 1998 Edition with 2000 Addenda.
~'~iY..OA..~JFAT.Ji
: 6. SI Calculation No. VY-16Q-303, Revision 0, "Environmental Fatigue Evaluation of Reactor Recirculation Inlet Nozzle and Vessel Shell/Bottom Head."
~i I Index Load #1I Desc. #1 Load #2 Desc #2 Line# T 1(4) st1(4 72(4) s2 (4) Sn (psi) T Fi) (1)1 1 lTrnl_ 14 4Trn4 176 "1 3 14 18 21902 339 2 1 ITrnl 37 2Trn9_ 6065 / 3 37 62 21390 437 3 1 ITrnl _ 16 6Trne_ 1060 I 3 16 7 15100 329 4 1 1Trn 1 27 2Trn6_ 3734 1 3 27 8 42301 526 5 2 2Trnl_ 45 2Trn12 20'1558 2 1 45 1 45773 120 6 1 iTrno is 15 5Tro4 1927 1 3 15 49 13457 394 7 -1Trnn 10 0Trn 4 223M I 3 18 10 335 8 I 1Trn 1 36 1Trn_ 5657 1 3 3M 41 20617 405 9 1 1Trn I 13 3Trn 4 1651 1 3 13 15 34179 516 10 1 iTrnl _ 30 3-rnS -6657 I 3 38 1 25904 490 11 I ITrnl 12 2Trn 4_ 1599 1 3 12 3 36762 526 12 1 1Trnl_ 23 1Trn5 311t5 1 3 23 27 35051 526 13 1 1Trnl_ 17 7Trn4 2152 1 3 17 5& 22210 426 14 1 ITrnl_ 5 3Trn2_ 952 1 3 5 80 29847 530 15 2 2TrnI 1 ITrr2_ 8718 2 1 5 79 29301 530 16 2 2Trn1l 20 5Trno_ 9R727 2 1 28 1 33856 526 17 2 2Trn _ 1 11 ITrn4 _ 42455 2 1 11 4 33460 526 18 2 2Trn 1_ 26 ITrn6_ 98465 2 1 26 3 32900 526 19 2 2Trn I_ 25 3irn5 89557 2 1 25 22 29068 529 20 2 2Trn I 29 4Trn_ 105503 2 1 29 21 29060 529 21 2 2Trn 1 8 3Trn3_ 35.741 2 1 8 5 29047 528 22 2 2 T rnl_ 4 2Trn2_ 7777 2 1 4 7 30245 5-43 23 4 2Trn2 41 1Trnl 233450 4 7 41 1 32229 543 24 4 2Trn2 32 3Trn7_ 223647 4 7 32 126 30983 543 25 4 2Trn2_ 40 2-r7ln 10- 232587 4 7 40 209 30982 543 26 '10 5Trn 3 40 2Trnl 0 1138571 10 21 40 209 31344 527 27 35 3TrnO 40 2Trn10_ 28?1140 35 51 40 209 2S931 528 20 35 3Trn. 43 3Trohl _ 2910647 35 51 4 3 1 29651 520 29 9 4Trn_ 43 3Trn 11- 106932C C 28 43 1 30915 536 30 7 2Trn3 46 3Trn 12_ 066274 7 42 46 1 30523 536 31 7 2Trn 3 44 1Trn12 860190 7 42 44 1 30523 536 32 7 27rn 3 43 3Trn11 860148 7 42 43 I 30523 536 33 3 1Trn2_ 43 3TrolI 206618 3 1 43 1 31236 549 34 3 1Trn2 19 9T"rn _ 203153 3 1 19 94 23810 549 35 31 2Trtn 42 2Trnl 1 26255.22 :31 809 42 1 27376 339 Uanv (3) -TMAX (TF) (1)TMAX (-1 Fen (Z)Uenv (3)2.45 201 2-45 4.46 0.001 335 100 2.45 3.04 0.001 495 257 2.45 0.50 0.000 516 269 2.45 9.03 0.001 490 254 2.45 8.31 0U000 526 274 2.45 10.49 0.001 520 274 2.45 10.49 0.007 426 219 2.45 5.4. 0.001 530 277 2.45 10.76 0.020 530 277 2.45 10.76 0.016 526 274 2.45 10.49 0.000 526 274 2.40 10.49 0.001 52, 274 2.45 10.49 0.000 520 276 2.45 10.60 0.005 520 276 2.45 10.69 0.000 520 276 2.45 10.63 0.001 543 204 2.45 11.71 0.008 543 204 2.45 11.71 0.011 543 204 2.45 11,71 0.000 543 2M4 2.45 11.71 0.007 527 275 2.45 10.56 0.001 520 276 2.45 10.63 0.013 528 276 2.45 10.63 0.002 536- 280 2.45 11.19 0.001 536 280 2.45 11.19 0.000 536 260 2.45 11.19 0.000 536 280 2.45 11.19 0.001 549 257 2.45 12.18 0.005 549 267 2.45 12.18 0.000 339 171 2.45 3.12 0.000 Total, U = 0.411 Overall Fen = 0,32 Notes: 1. T,,- is the maximum temperature of the two paired load states, and represents the metal (nodal) temperature at the location being analyzed.
: 7. Entergy Design Input Record (DIR) EC No. 1773, DIR. Revision 1, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY-1 6Q-209.
This.which is included as '" in the'Translent Maximum Temperatures" table above. determined from the VESLFAT output.2. F_ values computed using the low alloy steel equation from Section 3.0 of Reference
: 8. Deleted (not used in this calculation).
[6], with S* conservatively set to a maximuinvalue of 0.015, and tha transformed strain rate conservatively set to a minirmumvalue of In (0.001) = -6.90, for ali load pairs.3. U_, = [U x HIWC F_ x % HWC) + (U x NIWC F., x % NWVC1.4. T1 and T2 represent the load number for Load #1 and Load #2, respectively, and s l and s2 represent the state number for each of those loads.5. For each load pair, n- is the number of available cycles for Load #1, n. is the number of available cycles for Load 62. and n Ls the available number of cycles for the load pair (i.e.. the minimum of n, and nz).File No.: 0801038.306 Revision:
File No.: 0801038.306                                                                              Page 8 of 19 Revision: 1 F0306-OIRO
I Page 18 of 19 F0306-01 RO Structural Integrity Associates, Inc.Table 9: Linearized Stress Files Compiled for VY-RO-StressResults.xls Filename Description VY RONTRAN1-S.csv VYRONTRAN2-S.csv VY RON TRAN3-S.csv VY RON TRAN4-S.csv VY RON TRAN5-S.csv VY RON TRAN6-S.csv VY RONTRAN7-S.csv VY RON TRAN8-S.csv VY RON TRAN9-S.csv VYRON_ TRAN1O-S.csv VY RON TRAN11-S.csv VY RONTRAN12-S.csv Transient 1 linearized stress Transient 2 linearized stress Transient 3 linearized stress Transient 4 linearized stress Transient 5 linearized stress Transient 6 linearized stress Transient 7 linearized stress Transient 8 linearized stress Transient 9 linearized stress Transient 10 linearized stress Transient 11 linearized stress Transient 12 linearized stress Note: All files are from the Reference
 
[1] supporting computer files.File No.: 0801038.306 Revision:
StructuralIntegrity Associates, Inc.
1 Page 19 of 19 F0306-OIRO Hearing Docket From: Travieso-Diaz, Matias F. [matias.travieso-diaz@pillsburylaw.com]
Table 1: Safe End Load Sets as Input to VESLFAT VESLFAT                 Start ties Transient Time, see Temp Change  Pressure Change Cycles Load Set 1       lTrnl        0        Up            Up        300 2       2Tml      1616.4      Up            Up        300 3       1Tm2        0      Down          None        300 4       2Trn2_      0.4      Down          None        300 5      3Trn2        301      Down          None        300 6      4Trn2_    601.4      Down          None        300 7        1Trn3        0        Up          None        10 8       2Trn3        250        Up          None        10 9       3Tm3_      2050      Down          None        10 10      4Tm3_      2960    Up & Down        None        10 11       5Trn3_      5560      Down          None        10 12       lTrn4_      0        None            Up        10 13      2Trn4        2        None      Up & Down      10 14       3Trn4_        7      Down          Down        10 15       4Tm4_        46    Down & Up        None        10 16       5Tn4_        992    Up & Down        Down        10 17       6Tin4      2294    Down & Up    Down & Up      10 18       7Trn4_      3050    Up & Down    Up & Down      10 19       8Trn4_      6899    Down & Up        Down        10 20       9Trn4      7745        Up          Down        10 21       1OTm4_      8645        Up          Down        10 22       11Trn4_    11057        Up            Up        10 23       12Tin4    16166    Up & Down          Up        10 24       13Tm4_    16818      None          None        10 25       14Trn4    17118      Down          None        10 26       1Tn5_        0      None            Up        60 27       2Trn5        1.5      None      Up & Down      60 28        3Trn5        24        Up        Down & Up      60 29        4Trn5      2310      Down          None        60 30       5Trn5      2611      None          None        60 31       6Trn5    2911.4      Down          None        60 32         1Trn6        0      None            Up          1 33       2Trn6        0.6      None      Up & Down        1 34        3Trn6        20        Up        Down & Up        1 35        4Trn6_    2312      Down          None 36        5Tm6_      2613      None          None 37        6Tin6    2913.6      Down          None File No.: 0801038.306                                                                    Page 9 of 19 Revision: I F0306-O1RO
Sent: Tuesday, March 10, 2009 3:02 PM To: Alex Karlin; Richard Wardwell; whrcville@embarqmail.com; secy@nrc.gov; Hearing Docket;Susan Uttal; Lloyd Subin; Maxwell Smith; Sarah.hofmann@state.vt.us; aroisman@nationallegalscholars.com; peter.roth@doj.nh.gov; Matthew.Brock@state.ma.us; Zachary Kahn; Mr. Raymond Shadis; OCAAMAIL Resource Cc: Lewis, David R.; Nelson, Blake J.
 
VStructural IntegrityAssociates, Inc.
Table 1 (continued): Safe End Load Sets as Input to VESLFAT VESLFAT                Start ties Transient Time, see Temp Change Pressure Change Cycles Load Set 38      lTmn7        0      Down         Down 39      2Trn7      37.5      Down         Down 40      3Trn7        600      Down         Down 41      4Trn7      4443      Down         Down 42      1Trn8        0      None          Down       228 43      2Tm8_        3        Up       Down & Up     228 44      3Trn8_      2295      Down         None       228 45      4Trn8      3927      None         None        228 46      1Trn9        0      Down         None 47      2Trn9      0.12    Down & Up       None 48      3Trn9      27.92      Up           None 49      4Trn9    290.15      None         None 50      1TmlO_        0      Down         Down       300 51    2Trnm0      730.8      Down         Down       300 52    3TmlO_      6314      Down         Down       300 53    4Tm 10      6844      Down         Down       300 54    5TrnlO      9555      Down         Down       300 1
55    6TrnlO      14937      Down         Down       300 10 56      1Trnl 1       0      None          None        120 57    2Tml 1-        0      None          Up        120 58      3Trnl 1      0      None          Down        120 59      1Trnl2        0      None          None        1 60    2Trnl2        0      None            Up 61      3Trnl2        0      None          Down File No.: 0801038.306                                                                  Page 10 of 19 Revision: 1 F0306-0IRO
 
V StructuralIntegrity Associates, Inc.
Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT Start VESLFAT Transient Time, Temp Change   Pressure Change Cycles Load Set sec 1     1Tml        0     Up              Up        300 2      2Tml    808.2     Up              Up        300 3      1Trn2      0   Down            None      300 4      2Trn2_    0.4    Down             None      300 5    3Trn2_    401    Down             None      300 6      1Trn3_      0      Up             None       10 7      2Trn3    250  Up & Down         None       10 8      3Trn3  2325  Down & Up         None       10 9    4Trn3_  3510  Up & Down          None       10 10      5Trn3_  5060    Down            None        10 11      1Trn4_      0    None             Up        10 12      2Trn4_      2    None       Up & Down      10 13      3Trn4_      7    Down            Down         10 14    4Trn4_    46  Down & Up          None       10 15      5Trn4_  1091  Up & Down        Down        10 16      6Trn4_  2348  Down & Up     Down & Up      10 17      7Trn4_  3269  Up & Down      Up & Down      10 18      8Tm4_    6983  Down & Up        Down        10 19      9Trn4_  7745      Up        Down & Up      10 20    1OTrn4_  13839  Up & Down          Up        10 21    l1Trn4_  16918    Down            None        10 22    12Tn4_  18986    None            None        10 23      1Tn5_      0     None        Up & Down      60 24      2Tn5_      24  Up & Down      Down & Up      60 25     3Trn5_  2611    Down            None        60 26     1Trn6_      0    None            Up          1 27      2Tm6_    0.6    None        Up & Down      1 28      3Trn6_    20 Up & Down      Down & Up 29      4Trn6_  2663    Down            None 30      lTrn7      0     Down            Down 31      2Trn7_  37.5    Down            Down 32      3Trn7_  2247    Down            Down 33      1Trn8      0     None            Down      228 File No.: 0801038.306                                                                Page 11 of 19 Revision: 1 F0306-0IRO
 
StructuralIntegrity Associates, Inc.
Table 2 (continued): Nozzle Blend Radius Load Sets as Input to VESLFAT Start VESLFAT Transient      Time,       Temp Change    Pressure Change          Cycles Load Set sec 34          2Trn8_          3         Up & Down        Down & Up              228 35          3Trn8_      2025          Down                None              228 36          1Trn9_          0          Down                None                1 1
37          2Trn9_          9            Up                None 38          3Trn9_        58          None                None                1 39                          0          Down                Down              300 1I1Tml0I Trnl 0 40        2Tml0          313.2         Down                Down              300 41          1Trnl 1          0          None                None              120 42                          0          None                  Up              120 3Trnll                                                              120 43                          0          None                Down 44          1Trnl2          0          None                None                1 45        2Trnl2_          0          None                  Up                1 46        3Trnl2_          0          None                Down                1 Table 3: Temperature-Dependent Material Properties for VESLFAT (3)
Material              T, 'F    E x 106, psi    S., ksi       Sy, ksi SA-508 Class 2             70        27.8          26.7        50.0 (nozzle blend radius(2))      200        27.1          26.7        47.0 300        26.7          26.7        45.5 400        26.1         26.7        44.2 500        25.7          26.7        43.2 600        25.2          26.7        42.1 SA-182 F316              70        28.3           20          30 (Safe End (1))          200        27.6          20          25.9 300        27.0          20          23.4 400        26.5          19.3         21.4 500        25.8          18.0        20.0 600        25.3          17.0        18.9 Notes:
: 1. For the safe end material, SA-182 F316 (16Cr- 12Ni- 2Mo) austenitic stainless steel properties are used.
: 2. For the nozzle blend radius material, SA508 Class 2 material properties are used (3/4Ni-1/2Mo-1/3Cr-V), per Reference [2].
: 3. All values are taken from Reference [5].
: 4. SA-508 Class 2 in the Code of Construction is the same as SA-508 Gr. 2 Class 2 in the 1998 ASME Code [5].
File No.: 0801038.306                                                                                                      Page 12 of 19 Revision: I F0306-0IRO
 
StructuralIntegrity Associates, Inc.
Table 4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves Sa, ksi        Sa, ksi Number of Cycles      Carbon/Low Alloy (1)   Austenitic 10                580            708 20                  410            512 50                275            345 100                205            261 200                  155            201 500                  105            148 1000                  83              119 2000                  64              97 5000                  48              76 10000                  38              64 20000                  31            55.5 50000                  23            46.3 100000                  20            40.8 200000                16.5           35.9 500000                13.5            31 1000000                12.5            28.2 2.E+06                N/A            22.8(2) 5.E+06                N/A            18.4(2) 1.E+07                N/A            16.4(2) 2.E+07                N/A            15.2(2)
                                                                          ]4.3 (2) 5.E+07                N/A 1.E+08                N/A            14.1(2) 1.E+09              N/A            13.9(2) 1.E+10               N/A            13.7(2) 1.E+1I                N/A            13.6(2)
Note:
: 1. Using UTS _ 80 ksi curve.
: 2. Using Curve C for austenitic steel.
File No.: 0801038.306                                                                  Page 13 of 19 Revision: 1 F0306-OIRO
 
VStructural Integrity Associates, Inc.
Table 5: Pressure and Attached Piping Unit Load Case Stress Components Node                    Membrane plus Bending (1)                                                  Total (1) t 5      t 5 d(2)                    SY          S        S,                  yz        S"          SY.       S  z      Sx      Sxz    ) SyZ    )
Pressure  (3)    6395      -955.2       4420        10390    15.26      0        0       -955.2     4912      10530    -222.6      0         0 3829      -718.7      -951.7      25000      4708        0        0       -718.7      206.2     30150      733.2       0         0 4
ping( )        6395          0        7930          0        831    2066        0          0       12133          0       1271    3160        0 3829          0        218          0        42      49        0          0         218          0       42      49        0 Nuotes: I. All stress values are in uILts o psI.
: 2. The safe end location is represented by Node 6395, and the nozzle blend radius location is represented by Node 3829.
: 3. The stresses for both nodes represent the stress due to an applied pressure of 1,000 psig.
: 4. Piping stresses for both locations represent the stress due to full attached piping loads at an RPV temperature of 575'F.
: 5. Syz and S_ components have been rearranged from the ANSYS output in order to be in correct order for VESLFAT.
File No.: 0801038.306                                                                                                                Page 14 of 19 Revision: 1 F0306-0IRO
 
StructuralIntegrity Associates, Inc.
Table 6: Fatigue Usage Calculation for the Safe End Load        Desc. Load      Desc.                                          Salt
          #a        #1       #2        #2      n (cycles)    Sn (psi)      Ke      Si)      Nallow
          #1         #1       #2        #2                                            (psi)                    U 47      2Trn9      48      3Trn9_          1         79715      2.62  169777      331.52      0.00302 15      4Trn4_      49      4Trn9_          1         30275        1     23722    1757500      0.00000 15      4Trn4_      28      3Trn5          9          29755        1     23610    1784800      0.00001 19      8Trn4      28      3Trn5          10         26926        1     21352    2647400      0.00000 17      6Trn4_      28      3Trn5_        10         25213        1     20492    3155800      0.00000 28      3Trn5_      39      2Trn7_          1         20321        1     16926    8269400      0.00000 18      7Trn4      28      3Trn5_        10          19961        1     16731    8866300      0.00000 28      3Trn5      44      3Trn8_        20          4606        1     16450    9819700      0.00000 34      3Trn6_      44      3Trn8          1           4606        1     16450    9819700      0.00000 43      2Trn8_      44      3Trn8_        207          4606        1    16450    9819700      0.00002 6      4Trn2_      43      2Trn8_        21          4028        1     16176    11335000      0.00000 6      4Trn2_      35      4Trn6_          1           3519        1     15752    14441000      0.00000 6      4Trn2      29      4Trn5          60          3484        1     15637    15446000      0.00000 6      4Trn2_      22      11Trn4_        10          11783        1     15613    15666000      0.00000 6      4Trn2_      23      12Trn4_        10          3202        1     15588    15895000      0.00000 2      2Trnl_      6      4Trn2_        198          3193        1     15583    15936000      0.00001 2      2Trnl      31      6Trn5          60          3319        1    15531    16430000      0.00000 2      2Trnl      37      6Trn6          1           3319        1     15531    16430000      0.00000 2      2Trnl1      25      14Trn4_        10          1702        1     15055    23098000      0.00000 2      2Trnl_      40      3Trn7_          1         18894        1     14987    24732000      0.00000 2      2Trnl_      16      5Trn4_        10          5069        1     14487    41157000      0.00000 33      2Trn6      52    3Trnl_0          1         12380        1     14460    42317000      0.00000 13      2Trn4      52      3Trnl0        10          10470        1     13875  1.336E+09      0.00000 50      1Trnl0_    52      3Trnl0_      289          9634        1     13841  1.968E+09      0.00000 50      1TrnlO      53    4Trnl0          11          18796        1     13770  4.465E+09      0.00000 3      1Trn2      53    4Trnl0        289          18795        1     13769  4.491E+09      0.00000 Total      0.00308 Usage =
Note:        All other load pairs have an alternating stress, Saft, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.
File No.: 0801038.306                                                                                    Page 15 of 19 Revision: I F0306-O1RO
 
V StructuralIntegrity Associates, Inc.
Table 7: Fatigue Usage Calculation for the Nozzle Blend Radius Load      Desc. Load      Desc.       n                            Salt Nallow        U
            #1        #1      #2        #2      (cycles)  S    (psi)    Ke    (psi) 1Trnl1      14    4Trn4_      10      21902        1.00  43085      6889      0.0015 1Trnl_      37    2Trn9_        1      21390        1.00 32177      17617      0.0001 12    1Trn1_      16    6Trn4_      10        15100      1.00  31137      19701      0.0005 1    1Trnl_      27    2Trn6_        1      42381        1.00  27020      30496      0.0000 2    2Trnl_      45    2Trn12_        1      45773        1.00  26852      31084      0.0000 1    1Trnl_      15    5Trn4_      10        18457      1.00  26707      31604      0.0003 2    lTrnl_      18    8Trn4_      10        13066      1.00  26562      32139      0.0003 1    1Trnl_      36    1Trn9_        1      28617        1.00  24546      40947      0.0000 2                                              34179        1.00  24042      43643      0.0002 1    1Trn1_      13    3Trn4_      10 1    1Trnl_      38    3Trn9_        1      25904        1.00  23939      44218      0.0000 1    1Trn1_      12    2Trn4_      10      36762        1.00  23612      46129      0.0002 1    1Trnl_      23    1Trn5_      60      35051        1.00  22617      54348      0.0011 11    1Trn1_      17    7Trn4_      10      22210        1.00  22533      55358      0.0002 2    1Trnl_        5    3Trn2_      166      29847        1.00  22312      58126      0.0029 2    2Trnl_        5    3Trn2_      134      29301        1.00  22309      58168      0.0023 2    2Trnl_      28    3Trn6_        1      33856        1.00  22227      59234      0.0000 2    2Trn 1      11    1Trn4_      10      33460        1.00  21959      62919      0.0002 2    2Trnl1      26    1Trn6_        1      32908        1.00  21661      67330      0.0000 2    2Trnl_      25    3Trn5_      68      29068        1.00  21226      74454      0.0008 2    2Trnl1      29    4Trn6_        1      29068        1.00  21226      74454      0.0000 2    2Trnl1        8     3Trn3_      10      29847        1.00  21214      74661      0.0001 2Trnl_        4    2Trn2_      82      30245        1.00  21092      76819      0.0011 4    2Trn2_      41    1Trn 11      120      32229        1.00  20851      81328      0.0015 4    2Trn2_      32    3Trn7_        1       30983        1.00  20125      96967      0.0000 4   2Trn2_      40    2Trn 10_      97        30982      1.00 20124      96981      0.0010 10      5Trn3_      40    2Trn 10_      10        31344      1.00 20033      99198      0.0001 35      3Trn8_      40    2Trn 10_    193      29931        1.00   19888    102050      0.0019 35      3Trn8_      43    3Trnl 1_      35      29651        1.00   19696    105678      0.0003 9    4Trn3_      43    3Trn  11_    10        30915      1.00   19357    112494      0.0001 7    2Trn3_      46    3Trn12_        1        30523      1.00   19349    112655      0.0000 7   2Trn3_      44    1Trn12_        1       30523      1.00   19349    112655      0.0000 7    2Trn3_      43    3Trn 11        8       30523      1.00   19349    112655      0.0001 3    1Trn2_      43    3Trn 11_      67        31236      1.00   19331    113042      0.0006 3    1Trn2_      19    9Trn4_      10       23810      1.00   16958    181219      0.0001 31    2Trn7_      42    2Trnl I        1        27376      1.00   11515    infinite    0.0000 Total      0.0175 Usage =
Note:      All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.
File No.: 0801038.306                                                                                    Page 16 of 19 Revision: 1 F0306-O1RO
 
StructuralIntegrity Associates, Inc.
Table 8: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location VY RO flozzle Corner Environmental Fatique Calculation CUF Calculation from file NrY-RO-VFAT-2i.fat:
Index    Load.#1: Description#1     1 (cycles)(5 Load#21Description#2':n2Icycles)(5) (cycles) (5:  Sr,(pi)  K  S.(psi)  1`.1        U S        I            Trn_          300      14  i    4Trn4_
4          10          10        21902  1.00 43085    6889    0.0015 2                     1Trn1_          290        3r      2Trn9            1          1         21390  1.00   32177  17617    0.0001 3        1          1Trnl      I    289      16  i   6Trn4_          10         10         15100  1.00   31137  19701    0.0005 4         1         lTrnl          279        27      2Trn6    i      1           1         42381  1.00 .27020  30496    0.0000 5        2          27rnl            30G      451    2Trn 12            1                     45773  1.00 26852  31054    0.0000 6          1         1Trnl_
l                -78      18s      5Trn_4    i      10         10         18457  1.00 26707  31604    0,0003 7         1              1Trnt        268      18  i    8Trn4_    i      10          10         13066  1.00   26562  32139    0.0003 8          1n        125nl          L8        36      1Trn9            1          1        28617  1.00 24546  40947    0.0000 9         '1         lTrn      i    257        13      3Trn 4-          10         10        34179  1.00 24042  43643    0.0002 10         1i        1Trnl_          247      38      3Trn 9_          1           1         25904  1.00 23939  44218    0.0000 11          1           Trl          246        12 1     2Trn4            10          10        36762  1.00 23,612 46129      0.0002 12          1            Trnl          2        23      I1Trn5_  i      60        60          35051  1.00 22617    4348    0.0011 13          1         ITrnl            176      17      7Trn_            10         10         22210  1.00   22533  55358    0.0002 14          1      ITrnl              16,6              3Trn2          300        166        29847  1.00   22312  58126    0.0029 15        :2          2Trnl          299        5      3Trn2          134        134        29301  1.00  22309  E5168    0.0023 16        2          27rnl            165      28      3Trn6            1          1        33856  1.00 22227  59234    0.0000 17        2          .2Trnl 1          1S4      11      1Trn4    1      10          10        33460  1.00  21959  62919    0.0002 18        2          2Trnl            1        26      1 rn6            1          1        32908  1.00  21661  67330    0.0000 19        2          2Trnl1          153      25      3TrnS            60        60          29068  1.00  21226  74454    0.0008 20          2         2T rn    i      93      29      dTrn6_            1           1         29068  1.00  21226  74454    0.0000 21        2          27rnl            R2        8  i    3Trn3            10          10        29847  1.00  21214  74661    0.0001 22        2           2Trnl            82        4      2Trn2          300          82        30245  1.00  21092  76819    0.001.1 23          4             m 2rn2_            218      41  1   1Trn11-    1     120        120
* 32229  1.00  20851  81328    0.0015 24          4          2Trn2            98      32      3Trn7            1           1         30983  1.00  20125  06967    0.0000 25        .4          2Trn2            Q7      40  1         O 2Trnl10-         300          97        30082 1.00  20124    n- 1   0.0010 26        10          5Trn3            10      do      2Trn10_    i    203          10        31344  1.00  20033  99198    0.0001 27        35            7 mTrn        228      40      2Trn 10         193        193        29931  1.00  19589 102050    0.0019 28        35-         3Trn_            35      43      3Trnh1          120          35        29651  1.00  19698 105678    0.0003 29          9          4Trn3            10      43      3Trn11    1     85          10        30915  1.00  19357 112494    0.0001 4
30          7          2Trn3            10              3Trn12    i      1           1         30523  1.00  19349 112655    0.0000 31          7          2Trn3              9      44      1Trn12i            1           1         30523  1.00  19349 112655    0.0000 32          7          2Trn3              8      43    J3Trnl1            75          8        30523  1.00  19349 112655    0.0001 33          3            lTrn2          300      43      3Trn11            67          67        31236  1.00  19331 113042    0.0006 34          3          tTrn2          233      19      9Trn4    i      10          10        23810  1.00  16958 181219    0.0001 35    ,    31          2Tmn_              1      42      2T1rn1_    1     120          1.        27376  1.00  11515  infinte  0.0000 Total, U = 0.0175 File No.: 0801038.306                                                                                                                                        Page 17 of 19 Revision: 1 F0306-O1RO
 
Structural Integrity Associates, Inc.
Table 8 (continued): EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location EAF Calcuatina                      IIWC DO  rIlVLC  00 ndW8~,"uskumTh I.'4.r~/FI        48        122      ppb Transient Maximum Temperatures:                                                                                                                                            % HWC=  47%        53%      =% IIWc
                                                                      ~'~iY..OA..~JFAT.Ji ~i I TMAX (TF)(1)          TMAX (-1               Fen (Z)
(3)
Uanv (3)  -
Index    Load #1I Desc. #1 Load #2 Desc #2            Line#        T 1(4) st1(4    72(4) s2 (4) Sn (psi) T Fi)(1)                                                                                        Uenv 1          1       lTrnl_      14        4Trn4      176          "1     3      14    18    21902      339 2          1       ITrnl        37        2Trn9_      6065            /    3       37  62    21390      437 3          1       ITrnl _      16        6Trne_      1060          I    3       16    7     15100      329 4          1      1Trn 1       27        2Trn6_      3734          1     3       27    8    42301      526 5          2      2Trnl_        45      2Trn12    20'1558        2      1       45    1   45773      120                                                                  2.45 6          1       iTrno        15 is          5Tro4 4      1927          1     3       15  49    13457      394                                                          201     2-45     4.46         0.001 7                  1Trnn        10          -
0Trn      223M          I    3      18    10    1300*      335                                     335                  100   2.45       3.04         0.001 8          I      1Trn 1        36        1Trn_      5657          1      3      3M    41    20617      405                                      495                  257    2.45     0.50         0.000 9          1      1Trn I        13        3Trn 4      1651          1      3      13    15    34179      516                                     516                  269     2.45     9.03         0.001 10          1      iTrnl _      30        3-rnS      6657
                                                                    -          I      3      38    1    25904      490                                      490                 254     2.45     8.31         0U000 4                                                                                                    526                 274     2.45     10.49         0.001 11          I    ITrnl        12        2Trn _      1599          1      3      12    3    36762      526 12          1        1Trnl_      23        1Trn5      311t5        1      3      23  27    35051      526                                      520                  274    2.45     10.49         0.007 13          1        1Trnl_      17        7Trn4      2152          1      3      17    5&    22210      426                                     426                  219     2.45     5.4.         0.001 14          1      ITrnl_        5        3Trn2_      952          1      3        5    80    29847      530                                      530                  277    2.45    10.76         0.020 15          2      2TrnI 1                ITrr2_      8718          2      1        5  79    29301      530                                      530                 277     2.45     10.76         0.016 16          2      2Trn1l        20          5Trno_  9R727          2      1      28    1    33856      526                                      526                 274     2.45     10.49         0.000 17          2     2Trn 1 _      11        ITrn4 _  42455          2      1      11    4    33460      526                                      526                  274    2.40    10.49         0.001 18          2      2Trn1_        26        ITrn6_    98465          2      1      26    3    32900      526                                      52,                 274     2.45     10.49         0.000 2Trn I_      25        3irn5      89557          2      1      25  22    29068      529                                      520                 276     2.45     10.60         0.005 19          2 20          2     2Trn I        29        4Trn_    105503          2      1      29  21    29060      529                                      520                  276    2.45    10.69         0.000 21          2      2Trn 1        8        3Trn3_    35.741        2      1        8    5    29047      528                                      520                 276     2.45     10.63         0.001 T                                                                                                                                                    204     2.45     11.71         0.008 22          2     2 rnl_        4        2Trn2_      7777          2      1        4    7    30245      5-43                                    543 23          4      2Trn2        41        1Trnl    233450          4      7      41    1    32229      543                                      543                  204    2.45     11.71         0.011 24          4      2Trn2        32        3Trn7_    223647          4      7      32  126    30983      543                                      543                 204    2.45     11,71         0.000 543                                      543                  2M4    2.45     11.71          0.007 25          4      2Trn2_        40      2-r7ln10-  232587          4      7      40  209    30982 26        '10    5Trn 3        40        2Trnl 0  1138571        10    21      40  209    31344      527                                      527                  275    2.45     10.56          0.001 27        35      3TrnO        40      2Trn10_  28?1140        35      51      40  209    2S931      528                                     520                  276     2.45     10.63         0.013 20        35      3Trn.        43        3Trohl _ 2910647        35      51      43    1    29651      520                                      528                  276    2.45     10.63          0.002 29          9      4Trn_        43        3Trn 11-  106932C        C    28      43    1    30915      536                                      536-                280    2.45     11.19         0.001 2Trn3        46        3Trn 12_  066274          7      42      46    1    30523      536                                      536                 280    2.45     11.19         0.000 30          7 31          7      2Trn 3        44        1Trn12    860190          7      42      44    1    30523      536                                      536                 260    2.45     11.19         0.000 32          7      27rn 3        43        3Trn11    860148        7    42      43    I    30523      536                                      536                  280    2.45     11.19          0.001 33          3      1Trn2_        43        3TrolI    206618          3      1      43    1    31236      549                                      549                 257    2.45     12.18         0.005 34          3      1Trn2        19        9T"rn _  203153          3      1      19    94    23810      549                                      549                  267    2.45    12.18          0.000 35        31      2Trtn        42        2Trnl 1  26255.22        :31    809    42    1    27376      339                                      339                  171    2.45      3.12         0.000 Total, U =   0.411 Overall Fen =     0,32 Notes:   1. T,,- is the maximum temperature of the two paired load states, and represents the metal (nodal) temperature at the location being analyzed. This.
which is included as '" in the'Translent Maximum Temperatures" table above. determined from the VESLFAT output.
: 2. F_ values computed using the low alloy steel equation from Section 3.0 of Reference [6], with S* conservatively set to a maximuinvalue of 0.015, and tha transformed strain rate conservatively set to a minirmumvalue of In (0.001) =-6.90, for ali load pairs.
: 3. U_, = [U x HIWCF_ x % HWC) + (Ux NIWCF.,x % NWVC1.
: 4. T1 and T2 represent the load number for Load #1 and Load #2, respectively, and s l and s2 represent the state number for each of those loads.
: 5. For each load pair, n- is the number of available cycles for Load #1, n. is the number of available cycles for Load 62. and n Lsthe available number of cycles for the load pair (i.e.. the minimum of n, and nz).
File No.: 0801038.306                                                                                                                                                                                           Page 18 of 19 Revision: I F0306-01 RO
 
StructuralIntegrity Associates, Inc.
Table 9: Linearized Stress Files Compiled for VY-RO-StressResults.xls Filename                     Description VY RONTRAN1-S.csv             Transient 1 linearized stress VYRONTRAN2-S.csv             Transient 2 linearized stress VY RON TRAN3-S.csv           Transient 3 linearized stress VY RON TRAN4-S.csv           Transient 4 linearized stress VY RON TRAN5-S.csv           Transient 5 linearized stress VY RON TRAN6-S.csv           Transient 6 linearized stress VY RONTRAN7-S.csv             Transient 7 linearized stress VY RON TRAN8-S.csv           Transient 8 linearized stress VY RON TRAN9-S.csv           Transient 9 linearized stress VYRON_ TRAN1O-S.csv         Transient 10 linearized stress VY RON TRAN11-S.csv         Transient 11 linearized stress VY RONTRAN12-S.csv           Transient 12 linearized stress Note: All files are from the Reference [1] supporting computer files.
File No.: 0801038.306                                                                    Page 19 of 19 Revision: 1 F0306-OIRO
 
Hearing Docket From:                 Travieso-Diaz, Matias F. [matias.travieso-diaz@pillsburylaw.com]
Sent:                 Tuesday, March 10, 2009 3:02 PM To:                   Alex Karlin; Richard Wardwell; whrcville@embarqmail.com; secy@nrc.gov; Hearing Docket; Susan Uttal; Lloyd Subin; Maxwell Smith; Sarah.hofmann@state.vt.us; aroisman@nationallegalscholars.com; peter.roth@doj.nh.gov; Matthew.Brock@state.ma.us; Zachary Kahn; Mr. Raymond Shadis; OCAAMAIL Resource Cc:                   Lewis, David R.; Nelson, Blake J.


==Subject:==
==Subject:==
Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No. 50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)Attachments:
Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No. 50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)
Letter to ASLB enclosing revised calculations .pdf In accordance with the provisions of the Board's Partial Initial Decision (Ruling on Contentions 2A, 2B, 3, and 4), LBP-08-25, 68 N.R.C. _ (Nov. 24, 2008), slip op. at 67,.and the Board's Order (Clarifying Deadline for Filing New or Amended Contentions) (Mar. 9, 2009), Entergy has revised and issued its final calculations of record for the confirmatory environmentally assisted fatigue (CUFen) analyses on the reactor pressure vessel core spray (CS) and recirculation outlet (RO) nozzles at the Vermont Yankee Nuclear Power Station. These revised analyses are presented in the following Structural Integrity Associates, Inc. (SIA) calculations:
Attachments:           Letter to ASLB enclosing revised calculations .pdf In accordance with the provisions of the Board's Partial Initial Decision (Ruling on Contentions 2A, 2B, 3, and 4), LBP-08-25, 68 N.R.C.                   _     (Nov. 24, 2008), slip op. at 67,.and the Board's Order (Clarifying Deadline for Filing New or Amended Contentions) (Mar. 9, 2009), Entergy has revised and issued its final calculations of record for the confirmatory environmentally assisted fatigue (CUFen) analyses on the reactor pressure vessel core spray (CS) and recirculation outlet (RO) nozzles at the Vermont Yankee Nuclear Power Station. These revised analyses are presented in the following Structural Integrity Associates, Inc. (SIA) calculations: Calculation No.
Calculation No.0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.303, Revision 1, "Fatigue Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle;" Calculation No.0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle;" and Calculation No. 0801038.306, Revision 1, "Fatigue Analysis of Reactor Recirculation Outlet Nozzle." Calculation 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle" has not been revised so that the version sent to the parties on January 8, 2009 remains the final calculation of record. Entergy is serving at this time electronic copies of those analyses on the parties to the above captioned proceeding.
0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.303, Revision 1, "Fatigue Analysis of Reactor Core Spray Nozzle;"
The methodology applied in the referenced CS and RO confirmatory analyses is in accordance with the approach-used in the SIA calculations for the feedwater nozzle that were introduced into evidence in this proceeding, and contains no significantly different scientific or technical judgments from those used in the feedwater nozzle calculations.
Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle;" Calculation No.
See Calculation 0801038.301 at 4, n.1 and Calculation 0801038.304 at 4, n.1.As set forth in the referenced revised calculations, the limiting calculated CUFenS for the CS and RO nozzles are less than unity and are therefore acceptable.
0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle;" and Calculation No. 0801038.306, Revision 1, "Fatigue Analysis of Reactor Recirculation Outlet Nozzle." Calculation 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle" has not been revised so that the version sent to the parties on January 8, 2009 remains the final calculation of record. Entergy is serving at this time electronic copies of those analyses on the parties to the above captioned proceeding.
Hard copies are also being sent today by overnight mail to the NRC Staff, the New England Coalition and the Vermont Department of Public Service.1 This submittal comprises three electronic messages.
The methodology applied in the referenced CS and RO confirmatory analyses is in accordance with the approach-used in the SIA calculations for the feedwater nozzle that were introduced into evidence in this proceeding, and contains no significantly different scientific or technical judgments from those used in the feedwater nozzle calculations. See Calculation 0801038.301 at 4, n.1 and Calculation 0801038.304 at 4, n.1.
This first message, attaching Entergy's cover letter, is being transmitted to the entire service list. The second message, comprising the calculation package for the CS nozzle, is being transmitted only to the parties (including interested States). The third message, comprising the calculation package for the RO nozzle, is being forwarded only to the parties (including interested States).If you have any difficulty opening this attachment, please contact me at the number below.Matias F. Travieso-Diaz I Pillsbury Winthrop Shaw Pittman LLP Tel: 202.663.8142 I Fax: 202.663.8007 I Cell: 703.472.6463 2300 "N" Street, NW I Washington, DC 20037-1122 Email: matias.travieso-diaz(cpillsburylaw.com-Bio: www.pillsburylaw.com/matias.travieso-diaz
As set forth in the referenced revised calculations, the limiting calculated                 CUFenS for the CS and RO nozzles are less than unity and are therefore acceptable.
* Internal Revenue Service regulations generally provide that, for the purpose of avoiding federal tax penalties, a taxpayer may rely only on formal written advice meeting specific requirements.
Hard copies are also being sent today by overnight mail to the NRC Staff, the New England Coalition and the Vermont Department of Public Service.
Any tax advice in this message does not meet those requirements.
1
Accordingly, any such tax advice was not intended or written to be used, and it cannot be used, for the purpose of avoiding federal tax penalties that may be imposed on you or for the purpose of promoting, marketing or recommending to another party any tax-related matters.2 Received:
from mail .nrc.gov (148.184.176.41) by TWMS01 .nrc.gov (148.184.200.145) with Microsoft SMTP Server id 8.1.291.1; Tue, 10 Mar 2009 15:01:59 -0400 X-Ironport-ID:
mail1 X-SBRS: 5.3 X-MID: 278153 X-IronPort-Anti-Spam-Filtered:
true X-IronPort-Anti-Spam-Result:
AjOCAEVWtknM4/81mWdsb2JhbACCJhMYkIOBAQEBAQg LCgcRrlAJjwiCSxCBMQZh X-IronPort-AV:
E=Sophos;i="4.38,337,1233550800";
d="pdf ?scan'208,217";a="278153" Received:
from sfmms08.pillsburywinthrop.com (HELO sfemf02.PillsburyWinthrop.com)
([204.227.255.8])
by maill.nrc.gov with ESMTP; 10 Mar 2009 15:01:54 -0400 Received:
from [172.17.1.202]
by sfemf02.PillsburyWinthrop.com with ESMTP (SFPWSP SMTP Relay (Email Firewall v6.3.2));
Tue, 10 Mar 2009 12:01:38 -0700 X-Server-Uuid:
C488EB2B-C670-400C-9182-92FFDA1BD321 Received:
from dcxm0l .PillsburyWinthrop.com
([172.16.2.42])
by sfxims0l.PillsburyWinthrop.com with Microsoft SMTPSVC(6.0.3790.3959);
Tue, 10 Mar 2009 12:01:37 -0700 X-MimeOLE:
Produced By Microsoft Exchange V6.5 Content-Class:
urn:content-classes:message Return-Receipt-To: "Travieso-Diaz, Matias F."<matias.travieso-diaz@pillsburylaw.com>
MIME-Version:


==1.0 Disposition-Notification-To==
This submittal comprises three electronic messages. This first message, attaching Entergy's cover letter, is being transmitted to the entire service list. The second message, comprising the calculation package for the CS nozzle, is being transmitted only to the parties (including interested States). The third message, comprising the calculation package for the RO nozzle, is being forwarded only to the parties (including interested States).
"Travieso-Diaz, Matias F."<matias.travieso-diaz@pillsburylaw.com>
If you have any difficulty opening this attachment, please contact me at the number below.
Matias F. Travieso-Diaz I Pillsbury Winthrop Shaw Pittman LLP Tel: 202.663.8142 I Fax: 202.663.8007 I Cell: 703.472.6463 2300 "N"Street, NW I Washington, DC 20037-1122 Email: matias.travieso-diaz(cpillsburylaw.com-Bio: www.pillsburylaw.com/matias.travieso-diaz
* Internal Revenue Service regulations generally provide that, for the purpose of avoiding federal tax penalties, a taxpayer may rely only on formal written advice meeting specific requirements. Any tax advice in this message does not meet those requirements. Accordingly, any such tax advice was not intended or written to be used, and it cannot be used, for the purpose of avoiding federal tax penalties that may be imposed on you or for the purpose of promoting, marketing or recommending to another party any tax-related matters.
2
 
Received: from mail .nrc.gov (148.184.176.41) by TWMS01 .nrc.gov (148.184.200.145) with Microsoft SMTP Server id 8.1.291.1; Tue, 10 Mar 2009 15:01:59 -0400 X-Ironport-ID: mail1 X-SBRS: 5.3 X-MID: 278153 X-IronPort-Anti-Spam-Filtered: true X-IronPort-Anti-Spam-Result:
AjOCAEVWtknM4/81mWdsb2JhbACCJhMYkIOBAQEBAQg LCgcRrlAJjwiCSxCBMQZh X-IronPort-AV: E=Sophos;i="4.38,337,1233550800";
d="pdf ?scan'208,217";a="278153" Received: from sfmms08.pillsburywinthrop.com (HELO sfemf02.PillsburyWinthrop.com) ([204.227.255.8]) by maill.nrc.gov with ESMTP; 10 Mar 2009 15:01:54 -0400 Received: from [172.17.1.202] by sfemf02.PillsburyWinthrop.com with ESMTP (SFPWSP SMTP Relay (Email Firewall v6.3.2)); Tue, 10 Mar 2009 12:01:38 -0700 X-Server-Uuid: C488EB2B-C670-400C-9182-92FFDA1BD321 Received: from dcxm0l .PillsburyWinthrop.com ([172.16.2.42]) by sfxims0l.PillsburyWinthrop.com with Microsoft SMTPSVC(6.0.3790.3959); Tue, 10 Mar 2009 12:01:37 -0700 X-MimeOLE: Produced By Microsoft Exchange V6.5 Content-Class: urn:content-classes:message Return-Receipt-To: "Travieso-Diaz, Matias F."
<matias.travieso-diaz@pillsburylaw.com>
MIME-Version: 1.0 Disposition-Notification-To: "Travieso-Diaz, Matias F."
<matias.travieso-diaz@pillsburylaw.com>


==Subject:==
==Subject:==
Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No.50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)Date: Tue, 10 Mar 2009 15:01:32 -0400 Message-ID:
Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No.
50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)
Date: Tue, 10 Mar 2009 15:01:32 -0400 Message-ID:
<91 E8D41 B43905C4BB96FF78D93B1 ED3FO4ED919D@dcxm0l.PillsburyWinthrop.com>
<91 E8D41 B43905C4BB96FF78D93B1 ED3FO4ED919D@dcxm0l.PillsburyWinthrop.com>
X-MS-Has-Attach:
X-MS-Has-Attach:
X-MS-TNEF-Correlator:
X-MS-TNEF-Correlator:
Thread-Topic:
Thread-Topic: Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No.
Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No.50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)Thread-Index:
50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)
AcmhsqBNEl E/xb+NRnSr5e7LFNXrig==
Thread-Index: AcmhsqBNEl E/xb+NRnSr5e7LFNXrig==
From: "Travieso-Diaz, Matias F." <matias.travieso-diaz@pillsburylaw.com>
From: "Travieso-Diaz, Matias F." <matias.travieso-diaz@pillsburylaw.com>
To: <ask2@nrc.gov>, <rew@nrc.gov>, <whrcville@embarqmail.com>, <secy@nrc.gov>,<hearingdocket@nrc.gov>, <susan.uttal@nrc.gov>, <Ibs3@nrc.gov>,<maxwell.smith@nrc.gov>, <Sarah.hofmann@state.vt.us>,<aroisman@nationallegalscholars.com>, <peter.roth@doj.
To: <ask2@nrc.gov>, <rew@nrc.gov>, <whrcville@embarqmail.com>, <secy@nrc.gov>,
nh.gov>,<Matthew.
        <hearingdocket@nrc.gov>, <susan.uttal@nrc.gov>, <Ibs3@nrc.gov>,
Brock@state.ma.us>, <zachary.kahn@nrc.gov>, "Mr. Raymond Shadis"<shadis@prexar.com>, <OCAAMAIL@nrc.gov>
        <maxwell.smith@nrc.gov>, <Sarah.hofmann@state.vt.us>,
CC: "Lewis, David R." <david.lewis@pillsburylaw.com>, "Nelson, Blake J."<blake.nelson@pillsburylaw.com>
        <aroisman@nationallegalscholars.com>, <peter.roth@doj. nh.gov>,
Return-Path:
        <Matthew. Brock@state.ma.us>, <zachary.kahn@nrc.gov>, "Mr. Raymond Shadis"
matias.travieso-diaz@pillsburylaw.com X-OriginalArrivalTime:
        <shadis@prexar.com>, <OCAAMAIL@nrc.gov>
10 Mar 2009 19:01:37.0810 (UTC)
CC: "Lewis, David R." <david.lewis@pillsburylaw.com>, "Nelson, Blake J."
FILETIME=[A39E9720:01 C9A1 B2]X-WSS-ID:
        <blake.nelson@pillsburylaw.com>
65A86698220669178-01-01 Content-Type:
Return-Path: matias.travieso-diaz@pillsburylaw.com X-OriginalArrivalTime: 10 Mar 2009 19:01:37.0810 (UTC)
multipart/mixed; boundary="----.=NextPart_001_01 C9A1B2.AOA9441 B"}}
 
FILETIME=[A39E9720:01 C9A1 B2]
X-WSS-ID: 65A86698220669178-01-01 Content-Type: multipart/mixed; boundary="----.=NextPart_001_01 C9A1B2.AOA9441 B"}}

Revision as of 07:46, 14 November 2019

2009/03/10-Final Calculations of Record for the Confirmatory Environmentally Assisted Fatigue (Cufen) Analyses on the Reactor Pressure Vessel Core Spray (CS) and Recirculation Outlet (RO) Nozzles at Vermont Yankee
ML090840422
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 03/10/2009
From: Travieso-Diaz M
Entergy Nuclear Vermont Yankee, Entergy Operations, Pillsbury, Winthrop, Shaw, Pittman, LLP
To: Karlin A, Wendy Reed, Richard Wardwell
Atomic Safety and Licensing Board Panel
SECY RAS
References
50-271-LR, ASLBP 06-849-03-LR, RAS M-411
Download: ML090840422 (119)


Text

1) A i , t I ti . COPY 2300 N Street, N.W. Tel 202.663.8000 Washington, D.C. 20037-1 128 F~ax 202.663.8007 www.pillsburylaw.coni MATIAS F. TRAVwEso-DIAZ 202-663-8142 DOCKETED Matias.travieso-diaz@pillsburylaw.comn USNRC March 10, 2009 (3:02pm)

March 10, 2009 OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF Alex S. Karlin, Esq., Chairman Administrative Judge . '

Atomic Safety and Licensing Board Dr. William H. Reed Mail Stop T-3 F23 Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Mail Stop T-3 F23 Washington, D.C. 20555-0001 ' U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Administrative Judge Dr. Richard E. Wardwell Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 In the Matter of Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc.

(Vermont Yankee Nuclear Power Station)

Docket No. 50-271-LR; ASLBP No. 06-849-03-LR Gentlemen:

In accordance with the provisions of the Board's Partial Initial Decision (Ruling on Contentions 2A, 2B, 3, and 4), LBP-08-25, 68 N.R.C. (Nov. 24, 2008), slip op. at 67, and the Board's Order (Clarifying Deadline for Filing New or Amended Contentions) (Mar. 9, 2009),

Entergy has revised and issued its final calculations of record for the confirmatory environmentally assisted fatigue (CUFen) analyses on the reactor pressure vessel core spray (CS) and recirculation outlet (RO) nozzles at the Vermont Yankee Nuclear Power Station. These revised analyses are presented in the following Structural Integrity Associates, Inc. (SIA) calculations: Calculation No. 0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.303, Revision 1, "Fatigue Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle;" Calculation No.

0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle;" and Calculation No. 0801038.306, Revision 1, "Fatigue Analysis of Reactor Recirculation Outlet Nozzle." Calculation 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle" has not been revised so that the version sent to the parties on January 8, 2009 remains the final calculation of record.

O37~ T-o -5

March 10, 2009 Page 2 Entergy is serving at this time electronic copies of those analyses on the parties to the above captioned proceeding. Hard copies are also being sent today by overnight mail to the NRC Staff, the New England Coalition and the Vermont Department of Public Service.

The methodology applied in the referenced CS and RO confirmatory analyses is in accordance with the approach used in the SIA calculations for the feedwater nozzle that were introduced into evidence in this proceeding, and contains no significantly different scientific or technical judgments from those used in the feedwater nozzle calculations. See Calculation 0801038.301 at 4, n.1 and Calculation 0801038.304 at 4, n. 1.

As set forth in the referenced revised calculations, the limiting calculated CUFenS for the CS and RO nozzles are less than unity and are therefore acceptable.

Sincerely, Matias F. Travieso-Diaz Counsel for Entergy cc: Service List Pillsbury Winthrop Shaw Pittman LLP

CERTIFICATE OF SERVICE I hereby certify that copies of the foregoing letter were served on the persons listed below by deposit in the U.S. Mail, first class, postage prepaid; where indicated by an asterisk, by electronic mail; and where indicated by a double asterisk, by both overnight and electronic mail, this 1 0 th day of March, 2009.

  • Administrative Judge *Administrative Judge Alex S. Karlin, Esq., Chairman Dr. Richard E. Wardwell Atomic Safety and Licensing Board Atomic Safety and Licensing Board Mail Stop T-3 F23 Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Washington, DC 20555-0001 ask2(@nrc.gov rew(anrc.gov
  • Administrative Judge
  • Secretary Dr. William H. Reed Att'n: Rulemakings and Adjudications Staff 1819 Edgewood Lane Mail Stop 0-16 CI Charlottesville, VA 22902 U.S. Nuclear Regulatory Commission whrcville(ieinbarqmail.com Washington, DC 20555-0001 secy(anrc.gov, hearingdocket(Dnrc. gov
  • Office of Commission Appellate Adjudication Atomic Safety and Licensing.Board Mail Stop 0-16 C1 Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Washington, DC 20555-0001 OCAAmaila~nrc.gov
  • Lloyd Subin, Esq. **Sarah Hofmann, Esq.
  • Susan L. Uttal, Esq. Director of Public Advocacy
  • Maxwell C. Smith, Esq. Department of Public Service Office of the General Counsel 112 State Street - Drawer 20 Mail Stop O-15-D21 Montpelier, VT 05620-2601 U.S. Nuclear Regulatory Commission Sarah.hofinann(state.vt.us Washington, D.C. 20555-0001 LBS3@(cnrc.gov; susan.uttal(ynrc.gov; maxwell.smith(ai)nrc. gov Pillsbury Winthrop Shaw Pittman LLP
    • Anthony Z. Roisman, Esq. **Raymond Shadis National Legal Scholars Law Firm 37 Shadis Road 84 East Thetford Road PO Box 98 Lyme, NH 03768 Edgecomb, ME 04556 aroisman(-,nationalleaalscholars.com shadis(lprexar.comr
  • Peter L. Roth, Esq. *Zachary Kahn, Esq.

Office of the New Hampshire Attorney General Atomic Safety and Licensing Board Panel 33 Capitol Street Mail Stop T-3 F23 Concord, NH 03301 U.S. Nuclear Regulatory Commission Peter.roth(adoi.nh.gov Washington, DC 20555-0001 zachary.kalmn(arc. gov

  • Matthew Brock, Esq.

Assistant Attorney General Environmental Protection Division Office of the Attorney General One Ashburton Place, 18th Floor Boston, MA 02108 Matthew.Brocke,state.ma.us Matias F. Tr*avieso-Diaz Pillsbury Winthrop Shaw Pittman LLP

V StructuralIntegrityAssociates, Inc.

CALCULATION PACKAGE File No.: 0801038.302 Project No.: 0801038 Quality Program E Nuclear E- Commercial PROJECT NAME:

VY Confirmatory Analysis for the CS and RO Nozzles CONTRACT NO.:

10163217 Amendment 5 CLIENT: PLANT:

Entergy Nuclear Operations, Inc Vermont Yankee Nuclear Power Station CALCULATION TITLE:

Stress Analysis of Reactor Core Spray Nozzle Document Affected Project Manager Preparer(s) &

DocumentsAfted Revision Description Approval Checker(s)

Revision Pages Signature & Date Signatures & Date 01 - 15 Initial issue.

Gary L. Stevens Tyler D. Novotny Computer Files 01/06/09 01/06/09 Jennifer D. Correa

.01/06/09 1 1-3,7-8,11 Revised per summary / Preparer:

contained in Section 1.1. / &1t@ /

Computer Files Changes are marked with revision handbars" in right-Stevens margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker:

Tim D. Gilman 03/09/09 Page 1 of 15 F0306-O1RO

StructuralIntegrity Associates, Inc.

Table of Contents 1.0 O B JECTIV E ......... ....................................................................................................................... 3 1.1 Changes Made in Revision 1 of this Calculation ........................................................... 3 2.0 METHODOLOGY .............................................................................................................. 3 3.0 ASSUMPTIONS / DESIGN INPUTS ..................................................................................... 3 4.0 C A LCU L A T IO N S ........................................................................................................................ 3 4.1 Finite Element Unit Pressure Stress Analysis............................... 3 4.2 Thenr al Transient Stress Analysis ................................................................................ 4 4.3 Determining Critical Stress Paths ................................................................................. .5 4.4 Stress C alculation .......................................................................................................... 5 4 .5 P ip in g L o ad s .............................. ............................................................................................ 7 5.0 RESULTS OF ANALYSIS ..................................................................................................... 8 6.0 RE FEREN C E S ............................................................................................................................ 8 List of Tables Table 1: Pressure Results (1,000 psi) ............................................................................................. 6 Table 2: Stresses Under Unit Pressure Load, psi ................................... 9 Table 3: Membrane Plus Bending Stresses Due to Piping Loads ................................................ 10 Table 4: Example Thermal Stress Result Output, psi ..................................................................... 11 List of Figures Figure 1. Core Spray Nozzle Internal Pressure Distribution ....................... ................................ 12 Figure 2. Core Spray Nozzle Pressure Cap Load & Boundary Condition .................. 13 Figure 3. Core Spray Nozzle Vessel Wall Boundary Condition ........................ 14 Figure 4. Limiting Stress Paths ................................. ..................................................................... 15 FileNo.: 0801038.302 Page 2 of 15 Revision: 1 F0306-01RO

VStructural IntegrityAssociates, Inc.

1.0 OBJECTIVE The objective of this calculation package is to obtain stress distributions for the reactor pressure vessel (RPV) core spray (CS) nozzle at the Vermont Yankee Nuclear Power Station. ANSYS [1]

thernal transient and pressure stress analyses are performed, along with calculation of stresses due to attached piping loads. The stress results will be used for a subsequent ASME Code,Section III NB-3200 [2] fatigue usage calculation.

1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision 1 of this calculation:

a. All changes marked throughout this calculation are editorial changes made to the text of the calculation package.

2.0 METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package

[3]. A previously developed finite element model (FEM) [3] of the CS nozzle is used to perform thermal and pressure stress analyses using ANSYS [1]. A thermal transient analysis is performed for each defined transient. Concurrent with the thermal transients are pressure and piping interface loads. For these loads, unit load analyses (based on finite element analysis for pressure and manual calculations for attached piping loads) are performed. All six components of the stress tensor are determined in the stress calculations.

The fatigue usage calculation and environmental fatigue usage analysis will be performed in a separate calculation package. That subsequent calculation will utilize the thermal and pressure stresses determined in this calculation, along with stresses due to attached piping loads provided in Table 3. The stresses due to pressure and the attached piping loads will be scaled based on the temperature and pressure magnitudes during each individual transient, and the location being analyzed. From the Reference [3] calculation, the FEM includes a factor of two on the modeled RPV radius to account for the 3-D effects of two intersecting cylinders at the nozzle blend radius location.

3.0 ASSUMPTIONS / DESIGN INPUTS Assumptions and design inputs were previously established in Section 3.1 of the Reference [3]

calculation.

4.0 CALCULATIONS 4.1 Finite Element Unit Pressure Stress Analysis A uniform pressure of 1,000 psi was applied to the FEM along the inside surface of the CS nozzle and the RPV wall (Figure 1). A pressure load of 1,000 psi was used because it is easily scaled up or FileNo.: 0801038.302 Page 3 of 15 Revision: 1 F0306-O1RO

StructuralIntegrityAssociates, Inc.

down to account for different pressures that occur during transients. In addition, a membrane stress "cap load" was applied to the modeled end of the piping attached to the core spray nozzle safe end.

This membrane stress was calculated as follows:

p* Di2 cap - Do 2 - Di 2 where:

P = Pressure = 1,000 psi unit load Di= Inner Diameter at end of model = 9.834 in Do = Outer Diameter at end of model = 10.815 in Therefore, the membrane stress is 4,774 psi. The calculated value is given a negative sign in order for it to exert tension on the piping end of the model. The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, input file VYCSNGEOMINP].

The ANSYS input file VY 16Q_P.INP, as obtained from Appendix A of Reference [5], contains the pressure loading. Figure 1 shows the applied 1,000 psi internal pressure distribution. At the vessel wall, a symmetric boundary condition is applied. At the piping end of the model, axial displacement is coupled to simulate the effect of the attached piping that is not modeled. Figure 2 and Figure 3 show the boundary conditions.

4.2 Thermal Transient Stress Analysis The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, file VYCSNGEOM.INP], and is used as input to the files in which the thermal transient and pressure stress analyses are performed.

For the thermal transient ANSYS analyses, previously defined thernal transients [3, Table 2] are evaluated, applying heat transfer coefficients [3, Tables 4 through Table 18], as appropriate, based on the flow rates for each individual transient.

Each thermal transient is evaluated in ANSYS to determine the resulting temperature distributions.

The thermal results are used as input for the stress analysis for each transient. The boundary conditions used for the pressure load case were also applied to the thermal stress cases. Figure 2 and Figure 3 show the application of these boundary conditions.

All ANSYS input files for the thennal analyses, as listed below, are saved in the project computer files:

VY_CSNGEOM.INP: Geometry and material properties VY_16QTRAAN2-T.INP, VY 16QTRAN2-S.INP: Transient 2, thermal and stress analyses VY_16QTRAN3-T.INP, VY 16QTRAN3-S.INP: Transient 3, thermal and stress analyses VTY_ 6QTRAN11-T.INP, VYI 16QTRAN11-S.INP: Transient 11, thermal and stress analyses FileNo.: 0801038.302 Page 4 of 15 Revision: I F0306-O1RO

StructuralIntegrity Associates, Inc.

VY_16QTRAN14-T.JNP, VY 16QTRAN14-S.INP: Transient 14, thermal and stress analyses VYý_]6QTRAN21-23-T.INP, VY_ 6Q_TRAN21-23-S.INP: Transient 21-23, thermal and stress analyses VY_16QTRAN24-T.INP, VY 16QTRAN24-S.JNP: Transient 24, thermal and stress analyses VY_16QTRAN30-T.INP, VY 16QTRAN30-S.INP: Transient 30, thermal and stress analyses 4.3 Determining Critical Stress Paths From Section 4.0 of Reference [5], the critical location in the safe end was determined to be at Node 3719. This location was selected since it possessed the highest stress intensity during the worst case thermal transient.

Also from Section 4.0 of Reference [5], the critical stress location in the nozzle blend radius was chosen based upon the highest pressure stress (which is controlling in the nozzle blend radius). The pressure stress results showed the critical location in the nozzle blend radius to be at Node 2166.

Figure 4 shows the two critical stress paths that will be used to find the linearized stresses at the safe end and nozzle blend radius.

4.4 Stress Calculation Linearized stresses from Node 3719 (safe end inside surface) and Node 2166 (nozzle blend radius inside surface of base metal) are used for the fatigue usage analysis, as shown in Figure 4. For the nozzle blend radius location, the stresses used are for the base metal only; the cladding material is unselected prior to stress extraction.

The pressure stress intensities for the safe end and blend radius paths were extracted using the ANSYS file VY_]6QP.INP. This produced one file, PRESSURE.lin, which contains results of the critical stress paths.

Table 1 shows the final pressure results for the safe end and blend radius. These results are slightly different from those reported in Table 14 of Reference [5] as a result of the revised material properties (i.e., temperature dependent material properties were used in the current evaluation vs. constant material properties in Reference [5]).

FileNo.: 0801038.302 Page 5 of 15 Revision: 1 F0306-O1RO

VStructural Integrity Associates, Inc.

Table 1: Pressure Results (1,000 psi)

Membrane plus Total Stress Location Bending Stress Intensit Intensity (psi)

(psi)

Safe End 12,030 12,070 Blend Radius 30,720 36,150 Results were also extracted from the vessel portion of the model to verify the accuracy of the results obtained from the ANSYS model, and to check the results due to the use of the 2.0 multiplier on the vessel radius. These results are contained in the file PRESSURE.lin. The radius of the finite element model (FEM) was multiplied by a factor of 2.0 [3] to account for the fact that the vessel portion of the axisymmetric model is a sphere, but the true geometry is the intersection of two cylinders.

The equation for the membrane hoop stress in a sphere is:

(pressure)x (radius) 2 x thickness Considering a vessel base metal radius, R, of 105.906 inches increased by a factor of 2.0, a vessel base metal thickness, t, of 5.4375 inches, and an applied pressure, P, of 1,000 psi, the calculated stress for a sphere is PR/(2t) = 19,477 psi. This compares very well with the remote vessel wall membrane hoop stress from the ANSYS result file, PRESSURE.lin, of 18,960 psi. Thus, considering the peak total pressure stress of 36,150 psi reported above, the stress concentrating effect of the nozzle comer is 36,150/19,477 = 1.86. In other words, the peak nozzle comer stress is 1.86 times higher than nominal vessel wall stress for the axisymmetric model.

The equation for the membrane hoop stress in a cylinder is:

I

((pressure) x (radius))

thickness Based on the previous dimensions, the calculated stress for a cylinder without the 2.0 factor is 19,477 psi. Increasing this by a factor of 1.86 yields an expected peak nozzle comer stress of 36,227 psi, which would be expected from a cylindrical geometry that is representative of the nozzle configuration. Therefore, the result from the ANSYS file for the peak nozzle comer stress (36,150 psi) is close to the peak nozzle comer stress for a cylindrical geometry because of the use of the 2.0 File No.: 0801038.302 Page 6 of 15 Revision: 1 F0306-OIRO

StructuralIntegrity Associates, Inc.

multiplier. This is consistent with SI's experience where a factor of two increase in radius is typical for representing the 3-D effect in an axisymmetric model.

4.5 Piping Loads The piping loads per Reference [4] are as follows:

F, = 2,500 lbs Mx= 264,000 in-lb Fy = 4,600 lbs My= 85,200 in-lb F, = 1,700 lbs Mz= 105,600 in-lb The point of loads application is at the intersection between the safe end-to-pipe weld [4, 61]

Therefore, the safe end critical location is 0.303 inches and the nozzle blend radius is 30.817 inches from the load application point. (The nozzle blend radius location was measured from approximately the middle of the critical stress path for the blend radius and applied to the inside blend radius location along the critical stress path.) From general structural mechanics, the membrane plus bending stresses at the inside surface of a thick-walled cylinder are:

cyzl = axial stress due to axial force = Fz/A cy, = axial stress due to bending moment = Mxy(ID/2)/I (z = Tzl 5"z2

,re = shear stress due to torsion = Mz(ID/2)/J z = shear stress due to shear force = 2Fxy/A, where Fx, Fy, Fz, M,, My, and Mz are forces and moments at the pipe-to-safe end weld M* = moment about x axis translated by length z = -L = M, - Fy L MyL = moment about y axis translated by length z = -L = My + Fx L 2

Mxy = resultant bending moment = (MxL + MyL2)0.5 2

Fxy = resultant shear force = (Fx + Fy2)0.5 ID, OD = inside and outside diameters 2 2

A = area of cross section = (it/4)(OD - ID )

I = moment of inertia = (7/64)(OD 4 - ID 4)

J = polar moment of inertia = (7/32)(0D 4 - ID4)

The piping load stress calculations for these locations are shown in Table 3.

The piping loads tabulated in and pictorially shown in Reference [4] were applied by CB&I at the safe end-to-pipe weld. Refer to Reference [6], page 9 of 13; CB&I RPV Stress Report, Section S7.

FileNo.: 0801038.302 Page 7 of 15 Revision: 1 F0306-01RO

StructuralIntegrityAssociates, Inc.

5.0 RESULTS OF ANALYSIS A thermal transient analysis for each defined transient, as well as unit pressure stress and piping interface load analyses were performed for the CS nozzle at Vermont Yankee. All six components of the stress tensor were extracted from the ANSYS model at the two limiting path locations. Table 2 provides the unit pressure stress analysis results. The unit pressure load results are used to choose the location to analyze at the nozzle blend radius and will be scaled up or down based on applied pressures for the final fatigue analysis. Table 3 provides the piping stresses at the two critical locations. Table 4 shows an example of thermal stress results. The remaining thermal stress results are contained in the ANSYS output files, listed below, which are saved in the project computer files:

PRESSURE.lin: Unit pressure stress analysis results VY_16QTRAN2-S. lin: Transient 2, thermal stress analysis results VY_ 6QTRAN3-S. lin: Transient 3, thermal stress analysis results VY_16QTRANll-S.lin: Transient 11, thermal stress analysis results VY_16QTRAN14-S.lin: Transient 14, thernal stress analysis results VY_16QTRAN21-23-S. lih: Transient 21-23, thermal stress analysis results VY_16QTRAN24-S. lin: Transient 24, thermal stress analysis results VY_]6Q TRAN3 0-S. lin: Transient 30, thermal stress analysis results A fatigue calculation using the methodology of Subarticle NB-3200 of Section III of the ASME Code [2] and an environmental fatigue usage analysis will be performed in a separate calculation package using the stress results from this calculation.

The results of this calculation are used in a subsequent SIA Calculation No. 0801038.303, "Fatigue Analysis of Core Spray Nozzle."

6.0 REFERENCES

1. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.
2. ASME Boiler and Pressure Vessel Code,Section III, Subsection-NB, 1998 Edition with 2000 Addenda.
3. SI Calculation No. 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle."
4. VY Drawing 5920-0024, Revision 11, Sht. No. 7, "Reactor Vessel," (GE Drawing No.

919D294), SI File No. VY-05Q-241.

5. SI Calculation No. VY-16Q-309, Revision 1, "Core Spray Nozzle Green's Functions."
6. Entergy Design Input Record (DIR), Rev. 1, EC No. 1773, Rev. 0, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY- 16Q-209.

FileNo.: 0801038.302 Page 8 of 15 Revision: 1 F0306-01RO

StructuralIntegrity Associates, Inc.

Table 2: Stresses Under Unit Pressure Load, psi Membrane plus Bending Total Node S SY Sz Sxy Syz Sxz SX S Sz Sxy Syz Sxz SafeEnd 3719 -1011 4829 11010 -104.8 0 0 -1011 4912 11050 -85.31 0 0 Blend Radius 2166 -1052 1657 25960 4886 0 0 -1052 1720 35050 348.9 0 0 FileNo.: 0801038.302 Page 9 of 15 Revision: 1 F0306-01RO

StructuralIntegrity Associates, Inc.

Table 3: Membrane Plus Bending Stresses Due to Piping Loads Safe End Blend Radius Fx, kip 2.5 2.5 Fy, kip 4.6 4.6 F,, kip 1.7 1.7 Mx, kip-in 264 264 My, kip-in 85.2 85.2 M,, kip-in 105.6 105.6 L, in 0.30 30.82 MxL, kip-in 262.61 122.24 MyL, kip-in 85.96 162.24 MxY, kip-in 276.32 203.14 Fy,, kip-in 5.24 5.24 OD, in 10.82 24.25 ID,in 9.834 12.125 A, in2 15.91 346.40 I, in4 212.46 15914.32 J, in4 424.93 31828.64 a.,, ksi 0.107 0.005 az2, ksi 6.395 0.077 oz, ksi 6.502 0.082 "ro, ksi 1.222 0.020 cz, ksi 0.658 0.030 Note: The axial and shear stresses are expressed in a local coordinate system with r radial (X in ANSYS coordinates), 0 circumferential (Z in ANSYS coordinates), and Z axial (Y in ANSYS coordinates) components with respect to the nozzle centerline.

File No.: 0801038.302 Page 10 of 15 Revision: 1 F0306-01RO

StructuralIntegrity Associates, Inc.

Table 4: Example Thermal Stress Result Output, psi Membrane Plus Bending Total Transient NodeI I Time (s) I.Sx Sy Sz Sxy Syz Sxz' Sx Sy Sz Sxy Syz Sxz 0 48 288 696 -50 0 0 48 641 -86 0 10.002 49 280 689 -50 0 0 49 -11 630 -86 0 123.23 52 197 644 -53 0 0 52 -131 561 -89 0 1716.1 124 467 1587 -123 0 0 124 -293 1413 -212 0 6984.8 380 1918 5199 -385 0 0 380 -358 4733 -663 0 7946.2 430 2206 5907 -436 0 0 430 -365 5384 -752 0 8919 482 2506 6638 -489 0 0 482 -371 6056 -843 0 16055 845 4684 11830 -857 0 0 845 -352 10830 -1487 0 16164 -849 4707 11880 -861 0 0 849 -352 10880 -1494 0 3719 16304 850 4831 12000 -864 0 0 850 -219 11020 -1500 0 19448 851 5001 12110 -870 0 0 851 -45 11140 -1506 0 20622 851 5002 12110 -870 0 0 851 -44 11140 -1506 0 29155 851 5002 12110 -870 0 0 851 -44 11140 -1506 0 32155 851 5002 12110 -870 0 0 851 -44 11140 -1506 0 40155 851 5002 12110 -870 0 0 851 -44 11140 -1506 0 50155 851 5002 12110 -870 0 0 851 -44 11140 -1506 0 65155 851 5002 12110 -870 0 0 851 -44 11140 -1506 0 66165 851 5002 12110 -870 0 0 851 -44 11140 -1506 0 3

0 86 -140 1025 44 0 87 -1084 -628 -68 0 10.002 87 -141 1030 44 0 109 -1242 -955 -70 0 123.23 109 -210 1224 60 0 310 -3331 -4776 -184 0 1716.1 310 -1469 2676 359 0 794 -9114 -9547 -537 0 6984.8 794 -2777 8114 775 0 882 -10220 -10520 -607 0 7946.2 882 -3032 8912 812 0 973 -11350 -11470 -678 0 8919 973 -3298 9762 859 0 1553 -18930 -18300 -1177 0 16055 1553 -5119 14660 1049 0 1562 -19040 -18390 -1184 0 16164 1562 -5143 14730 1051 0 1545 -18980 -18070 -1190 0 2166 16304 1545 -5079 14620 1032 0 1433 -18220 -14130 -1169 0

.19448 1433 -3608 14270 632 0 1422 -18180 -13900 -1169 0 20622 1422 -3508 14050 566 0 1409 -18140 -13810, -1173 0 29155 1409 -3451 13540 461 0 1409 -18140 -13810 -1173 0 32155 1409 -3452 13520 459 0 1409 -18140 -13810 -1173 0 40155 1409 -3452 13510 458 0 1409 -18140 -13810 -1173 0 50155 1409 -3452 13510 458 0 1409 -18140 -13810 -1173 0 65155 1409 -3452 13510 458 0 1409 -18140 -13810 -1173 0 66165 1409 -3452 13510 458 0 1409 -18140 -13810 -1173 0 Note: Not all time steps are listed in this table.

File No.: 0801038.302 Page 11 of 15 Revision: 1 F0306-01RO

V StructuralIntegrityAssociates, Inc.

Figure 1. Core Spray Nozzle Internal Pressure Distribution File No.: 0801038.302 Page 12 of 15 Revision: 1 F0306-O1RO

StructuralIntearityAssociates, Inc.

inc.

Integrity Associates,

  • Structurai Core Spray Nozzle Finite Element Model Figure 2. Core Spray Nozzle Pressure Cap Load & Boundary Condition File No.: 0801038.302 Page 13 of 15 Revision: 1 F0306-01RO

StructuralIntegrity Associates, Inc.

Core Spray Nozzle Finite Element Model Figure 3. Core Spray Nozzle Vessel Wall Boundary Condition FileNo.: 0801038.302 Page 14 of 15 Revision: 1 F0306-O1RO

V StructuralIntegrity Associates, Inc.

V~~~~rd~N pi3t l~~l dpa

-0:1 NodE2166 C-r $pray :hzerirnre zl--es -o1q, Figure 4. Limiting Stress Paths FileNo.: 0801038.302 Page 15 of 15 Revision: 1 F0306-01RO

J V StructuralIntegrityAssociates, Inc. File No.: 0801038.303 Project No.: 0801038, CALCULATION PACKAGE ,Quality Program Z Nuclear L! Commercial PROJECT NAME:

VY Confirmatory Analysis for the CS and RO Nozzles CONTRACT NO.:

10163217 Amendment 5 CLIENT: PLANT:

Entergy Nuclear Operations, Inc Vermont Yankee Nuclear Power Station CALCULATION TITLE:

Fatigue Analysis of Reactor Core Spray Nozzle, Document Affected Project Manager Preparer(s) &

Revision Pages Revision Description Approval Checker(s)

Signature & Date Signatures & Date 0 1 - 18 Initial issue.

Gary L. Stevens Tyler Novotny Computer Files. 01/06/09 01/06/09 W. F. Weitze 01/06/09 1 1-3, 5-8, 11-12, Revised per summary .. Preparer:

17-18 contained in Section 1.1. / -

Changes are marked with Gary L. Stevens Computer Files. "revision bars" in right-hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker:

Tim D. Gilman 03/09/09 Page 1 of 18 F0306-O1RO

VStructural Integrity Associates, Inc.

Table of Contents 1.0 O B JEC T IVE ................................................................................................................................. 3 1.1 Changes Made in Revision 1 of this Calculation ........................... 3 2.0 M E TH O D O L O G Y ........................................................................................... ... ................... 3 3.0 D E SIG N IN P U TS ......................................................................................................................... 3 3.1 Stress C alculation .......................................................................................................... 3 3.2 Fatigue Usage Analysis, General .................................................................................. 4 3.3 Event Cycles, V ESLFA T ............................................................................................... 4 3.4 M aterial Properties, VESLFA T ..................................................................................... 5 3.5 Stress Indices ............................................................................................................. 5 4.0 C A L C U L A TION S ......................................................................................................................... 6 5.0 RESULTS OF ANALYSIS ............................................. 7

6.0 CONCLUSION

S AND DISCUSSIONS ............................................................................... 7 7.0 RE FEREN CE S ............................................................. ............................................................... 8 List of Tables Table 1: Safe End Load Sets as Input to VESLFAT ....................................................................... 9 Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT ....................................................... 10 Table 3: Temperature-Dependent Material Properties for VESLFAT .................... 11 Table 4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves .................... 12 Table 5: Pressure and Attached Piping Unit LoadCase Stress Components ................................. 13 Table 6: Fatigue Usage Calculation for the Safe End (Inconel) ....... ................. 13 Table 7: Fatigue Usage Calculation for the Safe End (Stainless Steel) .......................................... 14 Table 8: Fatigue Usage Calculation for the Nozzle Blend Radius ....................... 15 Table 9: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location ........................ 16 Table 10: Linearized Stress Files Compiled for VY-StressResults.xls ...................... 18 File No.: 0801038.303 Page 2 of 18 Revision: 1 F0306-01RO

VStructural Integrity Associates, Inc.

1.0 OBJECTIVE The objective of this calculation package is to perform an ASME Code,Section III fatigue usage evaluation and a plant-specific evaluation of reactor water environmental effects for the reactor pressure vessel (RPV) core spray (CS) nozzle at the Vermont Yankee Nuclear Power Station.

1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:

a. Changed Reference [1] to reflect revision of that document.
b. All other changes marked throughout this calculation are editorial changes made to the text of the calculation package.

2.0 METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package

[2]. Based on that methodology, thermal stresses, pressure stresses, and attached piping load stresses were developed in the Reference [1] calculation for use in a fatigue calculation. The thermal stresses are added to pressure stresses and attached piping load stresses 1 . Both the pressure and piping' load stresses are scaled based on the magnitudes of the pressure and nozzle temperature during each transient. All six components of the stress tensor from the stress results are used in the fatigue calculation.

The fatigue calculation is performed for both of the limiting safe end and nozzle blend radius locations, as determined in the Reference [1] calculation, and uses the methodology of Subarticle NB-3200 of Section III of the ASME Code [3]. An environmental fatigue usage analysis is also performed in this calculation applying the methodology described in Reference [6].

3.0 DESIGN INPUTS 3.1 Stress Calculation Linearized stress components at Node 3719 (limiting safe end path at inside surface) and Node 2166 (limiting nozzle blend radius path at inside surface) are used for the fatigue usage calculation, as shown in Figure 4 of Reference [1]. For the nozzle blend radius location, the stresses used in the evaluation are for the base metal only; that is, the cladding material is unselected prior to stress extraction. The stress components from the thermal stress analyses are combined with stress components due to pressure and piping loads. The linearized thermal stress components for each Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 70'F and the full values are reached at a reactor design temperature of 575F [2, Assumption 3.1.7]. In addition, design seismic and deadweight loads are also included and scaled in combination with the thermal loads for each transient. This combination, coupled with assigning the stress due to these loads the same sign as the thermal stress, is considered to be a very conservative treatment of the loads overall in that deadweight and design seismic loads are considered and scaled for every transient.

File No.: 0801038.303 Page 3 of 18 Revision: 1 F0306-OIRO

StructuralIntegrity Associates, Inc.

transient are taken from the relevant output files associated with the Reference [1] calculation (a sample of which was provided in Table 4 of Reference [1]). The unit pressure stress component results are taken from Table 2 of Reference [1]. Piping load stress components are taken from Table 3 of the Reference [I] calculation.

3.2 Fatigue Usage Analysis, General Structural Integrity's VESLFAT program [4] is used to perform the fatigue usage calculation in accordance with the fatigue usage portion of ASME Code Subarticle NB-3200 [3]. VESLFAT performs the analysis required by NB-3222.4(e) [3] for Service Levels A and B conditions defined by the user. The VESLFAT program computes the primary-plus-secondary and total stress ranges for all events and performs a correction for elastic-plastic analysis, if necessary.

The program computes the stress intensity range based on the stress component ranges for all event pairs [3, NB-3216.2]. The program evaluates the stress ranges for primary-plus-secondary and primary-plus-secondary-plus-peak stresses based on all six components of stress (3 normal and 3 shear stresses). If the primary-plus-secondary stress intensity range is greater than 3 Sm, the total stress range must be increased by the simplified elastic-plastic strain correction factor Ke, as described in NB-3228.5 [3]. The design stress intensity, Sm, is specified as a function of temperature. The input maximum temperature for both states of a load set pair is used to determine the temperature that Sm is determined from the user-defined values.

When more than one stress set is defined for either of the event pair loadings, the stress differences are determined for all of the potential stress pairs, saving the maximum for the event pair, based on the pair producing the largest alternating total stress intensity (Salt), including any effects of Ke. The principal stresses for the stress ranges are determined by solving for the roots of the following cubic equation2:

S3 _ (aix "+ aiy +k (iz)S2 -+- ((x (yy + a(y (iz + (iz U, - Sxyz -x2_ 2_-X yz2 )S

- ((Fxa (y Uz + 2rxy Txz T"yz - Uz Cxy -2 (y Txz -_ax Tyz ) 0 The stress intensities for the event pairs are reordered in decreasing order of Salt, including a correction for the ratio of modulus of elasticity (E) from the fatigue curve divided by E from the material evaluated at the maximum event temperature. This allows a fatigue table to be created to eliminate the number of cycles available for each of the transient events. This fatigue table is based on a worst-case progressive pairing of events in order of the most severe alternating stress to the least severe, allowing determination of a bounding fatigue usage per NB-3222.4(e) [3]. For each load set pair in the fatigue table, the allowable number of cycles is determined based on Salt.

3.3 Event Cycles, VESLFAT For the Vermont Yankee CS nozzle analysis, transients that consist of combined stress ramps are split so that each successive ramp is treated separately. Therefore, there are 25 load sets based on the combined stress changes for the safe end, and 27 load sets based on the combined stress changes 2 Note that a., a,, a,, etc. are used synonymously with S,, S,,, S., etc., in this calculation.

File No.: 0801038.303 Page 4 of 18 Revision: 1 F0306-OIRO

V StructuralIntegrityAssociates, Inc.

for the nozzle blend radius location. The reason the number of load sets are not equal for each path is because the time history stress results of those paths differ. Tables 1 and 2 show the load sets applicable to plant operation, with cycle counts per Table 2 of Reference [2], used as input to VESLFAT for the safe end and nozzle blend radius locations, respectively. The cycle counts of Reference [2] consider 60 years of operation; see Reference [8] for the numbers of cycles. The data from Table I is entered into the VESLFAT input files VY-VFA T-1I. CYC (safe end-Inconel) and VY-VFAT2-1I.CYC (safe end-Stainless Steel), and the data from Table 2 is entered into the. file VY-VFA T-21.CYC (nozzle blend radius).

3.4 Material Properties, VESLFAT Material properties are entered in VESLFAT input files VY-VFAT-]1.FDT (safe end-Inconel), VY-VY-VFAT2-1LFDT (safe end-Stainless Steel) and VY-VFAT-2I.FDT (nozzle blend radius). Table 3 lists the temperature-dependent material properties used in the analysis [5]. Table 4 lists the fatigue curve for the nozzle and safe end materials [3, Appendix I, Table 1-9.1 and Figure 1-9.1 (UTS < 80.0 ksi) for the nozzle blend radius, and Tables 1-9.1 and 1-9.2.2 (Curve C) and Figures 1-9.2.1 and 1-9.2.2 for both safe end locations]. Curve C is selected because it is the most conservative curve among the three extended curves for austenitic steel. VESLFAT automatically scales the stresses by the ratio of E on the fatigue curve to E in the analysis, for purposes of determining allowable numbers of cycles, as required by the ASME Code.

Other material properties are input as follows:

m 1.7, n = 0.3, parameters used to calculate Ke for the safe end location (both materials) [3, Table NB-3228.5(b)-1]

m = 2.0, n = 0.2, parameters used to calculate K, for the nozzle blend radius location [3, Table NB-3228.5(b)-I]

E from fatigue curve = 28,300 ksi [3, Appendix I, Figure 1-9.2] for the safe end locations.

E from fatigue curve = 30,000 ksi [3, Appendix I, Figure 1-9.1 ] for the nozzle blend radius location.

3.5 Stress Indices Stress indices are calculated per Reference [2, Section 3.8]. For the safe end location and using the ANSYS thermal stress results, the membrane plus bending stress results are multiplied by K3 and then are added to the peak thermal stress results to yield total thermal stress, taking guidance from Equation 11 of NB-3600 [3]. The total thermal stresses are then added to the total piping and total pressure stresses.

C1 = C2 = C3 = 1, because the ANSYS model is sufficient to account for the effects of gross structural discontinuity. The path for Node 2166 does not contain a weld and, therefore, does not take the same guidance from NB-3600. However, the path for Node 3719 uses guidance and the following values from NB-3600 for an "as welded girth butt weld":

K1 = 1.2, From Table 3681(a)-I of NB-3600 [3]

K 2 = 1.8, From Table 3681(a)-I of NB-3600 [3]

K 3 = 1.7, From Table 3681(a)-I of NB-3600 [3]

File No.: 0801038.303 Page 5 of 18 Revision: 1 F0306-OIRO

V StructuralIntegrity Associates, Inc.

The K values listed above are used to multiply the Membrane plus Bending stress results of the pressure load and piping load to yield Total Stress. So, Ki * (Memb+Bend)pressure = Total Stresspressure and K2 * (Memb+Bend)piping = Total StressPiping.

4.0 CALCULATIONS Table 5 contains the stress components at the locations of interest for the 1,000 psi unit pressure stress case [1, Table 2]. Table 5 also contains the stress components for the attached piping load unit stress case [1, Table 3], which correspond to a reactor design temperature of 575'F [2, Section 3.1.7].

The attached piping load stress components were applied assuming the same signs as the thermal stress, which yields the largest stress component ranges.

The stress indices for each location and loading scenario are calculated in the previous section. These stress indices are used in the Excel workbooks described below.

The calculations of all of the VESLFAT stress inputs are automated in Excel workbooks VY-VFAT-]i.xls (safe end-both materials) and VY-VFAT-2i.xls (nozzle blend radius). These files are organized with sheets labeled as follows:

  • Overview: Contains general information.
  • Other Stresses: Contains pressure and attached piping load stresses. As shown in Table 5, the pressure and thermal stresses use the membrane-plus-bending and total stress from the finite element analysis [1], and include stress indices where appropriate.

Rearranger: There are 7 Rearranger sheets, one for each thermal transient as analyzed by ANSYS. In these sheets, thermal stresses are copied from Excel workbook VY-StressResults.xls, and rearranged to conform to VESLFAT input format (including switching the shear stress components Sxz and Syz as required by VESLFAT). VY-StressResults.xls contains the results of the ANSYS stress linearization for each transient. The files contained within this workbook are shown in Table 10. Time-varying scale factors for the attached piping loads (based on path metal temperature) and pressure are determined, and used to scale the unit load case stresses, which are then added to the thermal stresses. Since the attached piping loads can act in any direction, the stresses due to the attached piping loads are assigned the same sign as the thermal stresses to maximize the component stresses.

Algebraic summation of all six stress components is performed for pressure, piping loads, and thermal stresses at each transient time step. The VESLFAT stress input also includes time-varying metal temperature, as obtained from the ANSYS output, which is used to determine temperature-dependent properties from the values in Table 3.

VESLFAT: Contains the VESLFAT stress input, as obtained from the Rearranger sheets.

Load set numbers are entered on this sheet, as defined in Table I and Table 2. These sheets are saved to VESLFAT input files VY-VFAT-]i.STR (safe end-Inconel), VY-VFAT2-1i.STR (safe end-Stainless Steel), and VY-VFAT-2i.STR (nozzle blend radius).

File No.: 0801038.303 Page 6 of 18 Revision: 1 F0306-O1RO

W StructuralIntegrityAssociates, Inc.

5.0 RESULTS OF ANALYSIS Table 6, Table 7 and Table 8 provide the detailed calculated 60-year fatigue usage, as obtained from VESLFAT output files VY-VFAT-11.FAT (safe end-Inconel), VY-VFAT2-1LFAT (safe end-Stainless Steel), and VY-VFAT-2L.FAT (nozzle blend radius). All VESLFAT input and output files are saved in the project computer files associated with this calculation.

From Table 6, the safe end (Inconel) cumulative usage factor (CUF) is 0.000174 for 60 years. From Table 7, the safe end (Stainless Steel) cumulative usage factor (CUF) is 0.000742 for 60 years.

From Table 8, the nozzle blend radius CUF is 0.0171 for 60 years.

From Table 1 of Reference [6], it was determined that hydrogen water chemistry (HWC) is available for 47% of the total 60-year operating period, and normal water chemistry (NWC) is present for the remaining 53% of the total 60-year operating period. From Table 1 of Reference [6], the dissolved oxygen values for the RPV upper vessel region (which is applicable to the CS nozzles) are 97 ppb for HWC conditions and 114 ppb for NWC conditions.

For the safe end location (Inconel), the environmental fatigue factor is determined based on Alloy 600 methodology consistent with Reference [7]. The overall Fen (fatigue life correction factor), per Reference [7], is 1.49 and can be applied to the CS nozzle safe end (Inconel) location based on identical materials, i.e. SB-166. The resulting Environmentally Assisted Fatigue (EAF) adjusted CUF value is 0.000174 x 1.49 = 0.000259, which is less than the allowable value of 1.0 and is therefore acceptable.

For the stainless steel piping, the environmental fatigue factors for post-HWC and pre-HWC are both 8.36 from Table 4 of Reference [6]. The overall environmental multiplier is 8.36. It results in an EAF adjusted CUF of 8.36 x 0.000742 = 0.00620 for 60 years, which is acceptable (i.e., less than the allowable value of 1.0).

Based on the detailed CUF calculation shown in Table 8, a detailed EAF adjusted CUF evaluation on a load-pair basis is provided for the nozzle blend radius location in Table 9. The overall Fen is 8.20.

The resulting EAF adjusted CUF value is 0.0171 x 8.20 = 0.140, which is less than the allowable value of 1.0 and is therefore acceptable.

6.0 CONCLUSION

S AND DISCUSSIONS Detailed fatigue calculations for the Vermont Yankee CS nozzle were performed based on the results of stress analyses previously performed [1]. The thermal stresses were combined with stresses due to pressure and attached piping loads, both of which were scaled based on the magnitudes of the pressure and metal temperature during each thermal transient. All six components of the stress tensor were used for the fatigue calculations. The fatigue calculations were performed at previously-determined limiting locations in the safe end and nozzle blend radius, and used the methodology of Subarticle NB-3200 of Section III of the ASME Code [3].

The 60-year CUF for the safe end location (Inconel) was determined to be 0.000 174, the safe end location (Stainless Steel) was determined to be 0.000742, and the CUF for the nozzle blend radius File No.: 0801038.303 Page 7 of 18 Revision: 1 F0306-O1RO

StructuralIntegrity Associates, Inc.

location was determined to be 0.0171. All three values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.

Detailed EAF assessments were also performed for the two CS nozzle locations. The 60-year EAF CUF for the safe end location was determined to be 0.000259 using standard Alloy 600 methodology

[7]. The 60-year EAF CUF for the safe end location (Stainless Steel) was determined to be 0.00620.

The 60-year EAF CUF for the nozzle blend radius location was determined to be 0.140 using temperature-dependent Fen multipliers for each load pair. All EAF CUF values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.

7.0 REFERENCES

1. Structural Integrity Associates Calculation No. 0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle."
2. Structural Integrity Associates Calculation No. 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle."
3. ASME Boiler and Pressure Vessel Code,Section III, 1998 Edition with 2000 Addenda.
4. VESLFAT, Version 1.42, 02/06/07, Structural Integrity Associates.
5. ASME Boiler and Pressure Vessel Code,Section II, Part D-Properties, 1998 Edition with 2000 Addenda.
6. SI Calculation No. VY-16Q-303, Revision 0, "Environmental Fatigue Evaluation of Reactor Recirculation Inlet Nozzle and Vessel Shell/Bottom Head."
7. EPRI Report No. TR-105759, "An Environmental Factor Approach to Account for Reactor Water Effects in Light Water Reactor Pressure Vessel and Piping Fatigue Evaluations,"

December 1995.

8. Entergy Design Input Record (DIR) EC No. 1773, DIR. Revision 1, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY- 16Q-209.

File No.: 0801038.303 Page 8 of 18 Revision: I F0306-OI RO

VStructural IntegrityAssociates, Inc.

Table 1: Safe End Load Sets as Input to VESLFAT VESLFAT Start Temp Change Pressure Change Transient tiee Cycles Load Set Time, sec Tm2 T1_ 0 None None 120 2 Trn2T2_ 0 None Up 120 3 Trn2T3_ 0 None Down 120 4 1Tm3r 0 Up Up 300 5 2Trn3 56.6 Up Up 300 6 I1Tml 1- 0 None Up & Down 10 7 2Trnl 1 5 Down Down 10 8 3Tml 1 26.962 Down None 10 9 4Trn I 1 207.34 Down & Up None 10 10 5TrnIl 1 1734.9 Up & Down Down 10 11 6Trnl 1 2332.6 Down & Up Down & UP 10 12 7Trnl 1 5625.1 Up & Down Up & Down 10 13 8Trnl 1 7125.4 Down & Up Down & Up 10 14 9Trnl 1 14315 Up & Down Up 10 15 1OTrnl 1 16749 Down None 10 16 lTrnl4 0 Down Down 1 17 2Tm14 270 Down Down 1 18 lTrn21 0 Down Down 300 19 2Trn2l 17.00 Down Down 300 20 Tn24_TI_ 0 None None 1 21 Tn24 T2 0 None Up 1 22 Tn24_T3_ 0 None Down 1 23 1Trn3O 0 Down Down 1 24 2Trn3O 12.2 Down Down 1 25 3Trn3O 631 None Down 1 File No.: 0801038.303 Page 9 of 18 Revision: I F0306-0IRO

StructuralIntearity Associates, Inc.

Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT Start VESLFAT Transient Time, Temp Change Pressure Change Cycles Load Set sec Inc.

Trn2_TI 0 None None 120 Associates, Structurai Integrity Trn2_T2_ 0 None Up 120 Trn2_T3_ 0 None Down 120 1Trn3_ .0 Up Up 300 2Trn3 56.6 Up Up 300 ITrnll1 0 None Up & Down 10 2Trn I1_ 5 Down Down 10 3Trnl 1 142.64 Down & Up None 10 4Trnl 1 1655.2 Up & Down Down 10 5Trnl I 2302.7 Down & Up Down & Up 10 6Trn 11 3193.7 Up & Down Up & Down 10 7Trnl I 7255.1 Down & Up Down 10 8Trnl I 9913 Up Down & Up 10 9Trnll1 12514 Up and Down Up 10 1Trnl4_ 0 Down Down 2Tm14 2Trnl4_ 40 Down Down 3Tm14 1200 Down Down 1Tmn21I 0 Down Down 300 2Tin21I 32.15 Down Down 300 3Tm2l1 6462.7 Down None 300 Tn24_Ti1 0 None None 1 Tn24 T2 0 None Up 1 Tn24_T3_ 0 None Down 1 1Tm30_ 0 None Down 1 2Tmn3O 1.2 Down Down 1 3Tmn30 25 Down Down 1 4Tmn30_ 3331 Down Down 1 File No.: 0801038.303 Page 10 of 18 Revision: 1 F0306-O1RO

StructuralIntegrityAssociates, Inc.

Table 3: Temperature-Dependent Material Properties for VESLFAT (4)

Material T, OF E x 106 , psi S., ksi Sy, ksi SB-166 Inconel 70 31.0 23.3 35.0

.(safe end(') 200 30.2 23.3 32.0 300 29.8 23.3 31.2 400 29.5 23.3 30.7 500 29.0 23.3 30.3 600 28.7 23.3 29.9

  • SA-508 Class 2 (5) 70 27.8 26.7 50.0 (Nozzle blend radius (2)) 200 27.1 26.7 47.0 300 26.7 26.7 45.5 400 26.1 26.7 44.2 500 25.7 26.7 43.2 600 25.2 26.7 42.1 SA-312 TP 304 70 28.3 20 30 (Core Spray Piping 27.6 200 20 25 8 x 10 Reducer (3))

300 27.0 20 22.4 400 26.5 18.7 20.7 500 25.8 17.5 19.4 600 25.3 16.4 18.4 Notes:

1. For the safe end material, SB-166 Inconel properties are used (72Ni-15Cr-8Fe), per Reference [2]. Annealed heat treatment is conservatively assumed for Sm and Sy values.
2. For the nozzle blend radius material, SA508 Class 2 material properties are used (3/4Ni-1/2Mo-1/3Cr-V), per Reference [2].
3. For the nozzle safe end extension material, SA-312 TP304 material properties are used (18Cr-8Ni), per Reference [2].
4. All values are taken from Reference [5].
5. SA-508 Class 2 in the Code of Construction is the same as SA-508 Gr. 2 Class 2 in the 1998 ASME Code [5]

File No.: 0801038.303 Page 11I of 18 Revision: 1 F0306-O1RO

6 StructuralIntegrityAssociates, Inc.

Table 4: Carbon/Low Alloy Steel and Stainless Steel/Nickel Alloy Fatigue Curves Sa, ksi S,, ksi Number of Cycles Carbon/Low Alloy (1) Austenitic/Nickel Alloy 10 580 708 20 410 512 50 275 345 100 205 261 200 155 201 500 105 148 1000 83 119 2000 64 97 5000 48 76 10000 38 64 20000 31 55.5 50000 23 46.3 100000 20 40.8 200000 16.5 35.9 500000 13.5 31 1000000 12.5 28.2 2.E+06 N/A 22.8(2) 5.E+06 N/A 18.4(2) 1.E+07 N/A 16.4(2) 2.E+07 N/A 15.2(2) 5.E+07 N/A 14.3(2) 1.E+08 N/A 14.1(2) 1.E+09 N/A 13.9(2) 1.E+10 N/A 13.7(2) 1.E+311 N/A 13.6(2)

Note:

1. Using UTS _ 80 ksi curve.
2. Using Curve C for austenitic steel/nickel alloy.

File No.: 0801038.303 Page 12 of 18 Revision: I F0306-OIRO

StructuralIntegrityAssociates, Inc.

Table 5: Pressure and Attached Piping Unit Load Case Stress Components Membrane plus Bending (1) Total )

Node S y"(

s) Sy (5) S Sx Sz(s5)

Load (2) Sx SY Sz Sy Sxz S S S Sxz yZ Pressure(3) 3719 -1011 4829 11010 -104.8 0 0 -1011 4912 11050 -85.31 0 0 2166 -1052 1657 25960 4886 0 0 -1052 1720 35050 348.9 0 0 Piping(4) 3719 0 6502 0 658 1222 0 0 11704 0 1184 2200 0 2166 0 82 0 30 20 0 0 82 0 30 20 0

'MnM, 1 All otr*-oc ,an m or* , nnitc nfendf

2. The safe end location is represented by Node 3719, and the nozzle blend radius location is represented by Node 2166.
3. The stresses for both nodes represent the stress due to an applied pressure of 1,000 psig.
4. Piping stresses for both locations represent the stress due to full attached piping loads at an RPV temperature of 575'F.
5. Sy. and S. components have been rearranged from the ANSYS output in order to be in correct order for VESLFAT.

Table 6: Fatigue Usage Calculation for the Safe End (Inconel)

Load Load Salt

  1. 1 Desc. #1 #2 Desc. #2 n (cvcles) Sn (psi) Ke (psi) Nallow U 24 2Trn3O 25 3Trn3O_ 1 67883 63663 10260 0.000098 17 2Trn 14 23 1Trn30 1 44360 48903 37919 0.000026 5 2Trn3_ .8 3Trn 1_ 10 26107 18347 5088300 0.000002 5 2Trn3 9 4Trn 11_ 10 25551 17850 6002500 0.000002 5 2Trn3 6 1Trn 11 10 24728 16797 8657500 0.000001 5 2Tm3_ 7 2Tn I I_ 10 24429 16784 8698300 0.000001 5 2Trn3 10 5Trnl 1_ 10 23571 16559 9436700 0.000001 5 2Trn3_ 14 9Trn 1I- 10 23593 16507 9615800 0.000001 5 2Trn3_ 11 6Trnl 1_ 10 23214 16399 10007000 0.000001 5 2Trn3_ 15 1OTrnl 11 10 23358 16262 10800000 0.000001 5 2Trn3_ .12 7Trnl 1 10 23247 15968 12760000 0.000001 4 1Trn3_ 5 2Trn3_ 210 23000 15922 13097000 0.000016 4 1Trn3_ 19 2Trn21l 90 22979 15914 13155000 0.000007 1 Trn2_Ti1 19 2Trn2l_ 120 22979 15899 .13273000 0.000009 19 2Trn2l_ 20 Tn24_TI1 1 22383 15552 16233000 0.000000 19 2Trn2l1 22 Tn24_T3_ 1 22383 15552 16233000 0.000000 3 Trn2_T3_ 19 2Tm2l_ 88 22383 15552 16233000 0.000005 3 Trn2_T3_ 18 1Trn21 32 22389 15549 16263000 0.000002 Total Usage 0.000174 Note: All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.

File No.: 0801038.303 Page 13 of 18 Revision: 1 F0306-0IRO

StructuralIntegrity Associates, Inc.

Table 7: Fatigue Usage Calculation for the Safe End (Stainless Steel)

Load Load Salt Desc. #1 Desc. #2 n (cycles) Sn (psi) Ke Nallow U

  1. 1 #2 (psi) 24 2Trn3O 25 3Trn3O_ 1 68465 1.47 101779 1699.05 0.000589 17 2Trn 14 23 1Trn30 1 44360 1 54103 22751 0.000044 5 2Trn3 8 3Trn 11_ 10 26107 1 20551 3117000 0.000003 5 2Trn3 9 4Trn 11_ 10 25551 1 19856 3611400 0.000003 5 2Trn3 6 1Trn 11 10 24728 1 18923 4435200 0.000002 5 2Trn3_ 7 2Trnl 1_ 10 24429 1 18905 4453400 0.000002 5 2Trn3_ 14 9Trnl 1_ 10 23593 1 18620 4752000 0.000002 5 2Trn3_ 10 5Trnl 11 10 23626 1 18525 4857700 0.000002 5 2Trn3_ 15 1OTrnl 11 10 23358 1 18336 5106400 0.000002 5 2Trn3_ 11 6Trn 1I- 10 23214 1 18295 5175200 0.000002 4 1Trn3_ 5 2Trn3_ 23000 1 17975 5755400 0.000038 4 1Trn3_ 19 2Trn2l_ 22979 1 17967 5772000 0.000014 1 Trn2 T1 19 2Trn2l_ 22979 1 17949 5806200 0.000021 19 2Trn21 20 Tn24 Ti 22383 1 17557 6632000 0.000000 19 2Trn2l 22 Tn24_T3_ 22383 1 17557 6632000 0.000000 3 Trn2 T3 19 2Trn2l 22383 1 17557 6632000 0.000015 3 Trn2_T3_ 18 1Trn21_ 22 22389 1 17554 6640000 0.000003 Total 0.000742 Usage =

Note: All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.

File No.: 0801038.303 Page 14 of 18 Revision: 1 F0306-01RO

VStructural IntegrityAssociates, Inc.

Table 8: Fatigue Usage Calculation for the Nozzle Blend Radius Load

  1. 1 Desc. #1 Load L#2 Desc. #2 n (cycles) Sn (psi) Ke Salt (psi) Nallow U 25 2Trn3O0 26 3Trn3O0 1 51402 1.00 44455 6278 0.0002 8 3Trnl 1_ 13 8Trnl 1_ 10 15961 1.00 39383 8994 0.0011 19 2Trn21 22 Tn24_T2_ 1 39644 1.00 34138 14404 0.0001 7 2Trnl 1 27 4Trn3O0 1 38618 1.00 27466 28999 0.0000 4 1Trn3_ 7 2Trnl 1_ 9 36665 1.00 27150 30048 0.0003 10 5Trn11 _ 19 2Trn21l 10 15935 1.00 26332 33005 0.0003 1 Trn2 TI 6 1Trn 11 10 49693 1.00 25486 36486 0.0003 2 Trn2_T2_ 19 2Trn21, 120 25423 1.00 24010 43822 0.0027 12 7Trnl 1 19 2Trn21 10 13983 1.00 23200 48691 0.0002 1 Trn2_Ti1 9 4Trnl 1 10 47005 1.00 22776 52484 0.0002 4 1Trn3_ 11 6Trn 11_ 10 35885 1.00 22731 53008 0.0002 1 Trn2 T1 5 2Trn3 100 44974 1.00 22190 59737 0.0017 4 1Trn3_ 5 2Trn3_ 200 44974 1.00 22190 59737 0.0033 4 1Trn3_ 24 lTrn30- 1 44912 1.00 22187 59767 0.0000 4 1Trn3_ 18 1Trn21_ 80 44912 1.00 22187 59767 0.0013 17 3Trn14_ 18 1Trn21_ 1 44598 1.00 21478 70216 0.0000 18 1Trn21_ 20 3Trn21_ 219 43608 1.00 21218 74590 0.0029 19 2Trn21_ 20 3Trn21_ 81 43426 1.00 21130 76147 0.0011 3 Trn2_T3_ 19 2Trn21l 78 43219 1.00 21117 76367 0.0010 3 Trn2 T3 14 9Trn 11_ 10 43408 1.00 21016 78221 0.0001 3 Trn2_T3_ 15 1Trn14_ 1 42722 1.00 20993 78639 0.0000 3 Trn2_T3_ 16 2Trn14_ 1 41044 1.00 20341 91957 0.0000 Total 0.0171 Usage =

Note: All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.

File No.: 0801038.303 Page 15 of 18 Revision: 1 F0306-OIRO

C StructuralIntegrity Associates, Inc.

Table 9: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location VY CS Nozzle Corner Environmental Fatigue Calculation CUF Calculation from file VY-VFAT-2i.fat:

Index Load #1: Description #1: n1 (cycles) t5) Load #2&Description #2i n 2 (cycles) t5 ycles} 's SK psi t lt (psi} Nallmy U 1 25 2Trn30_ 1 26 i 3Trn3O_ 1 1 51402 1.00 44455 6278 0.0002 2 8 i 3Trnl_ 10 13 i 8Trn11_ i 10 10 15961 1-00 39383 8994 0.0011 3 19 i 2Trn21 300 22 Tn24 T2 ' 1 1 39644 1.00 34138 14404 0-0001 4 7 2Trnl1 10 27 4Trn30 1 1 38618 1-00 27466 28999 0.0000 5 4 1Trn3 300 7 2Trn11- 9 9 36665 1.00 27150 30048 0.0003 6 10 5Trn11 10 19 2Trn21 299 10 15935 1.00 26332 33005 0.0003 7 1 1 Trn2 TI 120 6 iTrnl 1 10 10 49693 1.00 25486. 36486 0.0003 8 2 Trn2 T2 120 19 2Trn2l 289 120 25423 1.00 24010 43822 0.0027 9 12 7Tlr 11 i 10 19 i 2Trn21- 169 10 13983 1.00 23200 48691 0.0002 10 1 ITrn2 Ti 110 9 4Trn11 10 10 47005 1.00 22776 52484 0.0002 11 4 1Trn3 291 11 6Trn11- 10 10 35885 1.00 22731 53008 0.0002 12 1 Trn2 T1 100 5 2Trn3 300 100 44974 1.00 22190 59737 0.0017 13 4 1Tr,3 281 2Trn3 200 200 44974 1.00 22190 59737 0.0033 14 4 1Trn3 81 24 OTrn3_ 1 1 44912 1.00 22187 59767 0.0000 15 4 lTrn3 80 18 1 Trn21 300 80 44912 1.00 22187 59767 0.0013 16 17 3Trn14 1 18 1Trn21_ 220 1 44598 1.00 21478 70216 0.0000 17 18 1Trn21 i 219 20 i 3Trn21 i 300 219 43608 1.00 21218 74590 0.0029 18 19 2Trn21 159 20 i 3Trn21 81 81 43426 1.00 21130 76147 0.0011 19 3 Trn2 T3 120 19 2Trn21 78 78 43219 1.00 21117 76367 0.0010 20 3 Trn2 T3 42 14 9Trn11- 10 10 43408 1.00 21016 78221 0.0001 21 3 Trn2 T3 32 15 1Tm14- 1 1 42722 1.00 20993 78639 0.0000 22 3 Trn2 T3- 31 16 1 2Trn14 1 1 41044 1.00 20341 91957 0.1000 Total, U = 0.0171 File No.: 0801038.303 Page 16 of 18 Revision: I F0306-0IRO

Structural Integrity Associates, -Inc.

Table 9 (Continued): EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location EAF Calculations: HWC DO HWC D0O (00 and HWCINWC inputs fromTable 1 of Reference [6}) 97 114 ppb Transient Maximum Temperatures:  %, HWC = 0.47 0.53 =%NWC Frnm "V'Y-VtFAT-2i AlII '

Index Load #1 Desc. #1 Load #21 Desc.#2 Line # Ti (4) si(4) T2(4) s2(4] Sn (psi) T (IF) (1) TMAX -F) (1) TMAX ('C) HWC Fen (2)NWC Fen (2) Uenv (3) 1 25 2Trn30- 26 3Trn3O 591851 25 15 26 30 51402 543 543 2.54 6.49 10.65 0.002 2 B 3Trnhl _ 13 UTrnh1 - 127122 8 30 13 14 15961 3D1 391 199 3.68 4.22 0.005 3 19 2Trn21 22 Tn24 T.2 574137 19 20 22 39644 359 389 1 5'8 3.54 4.17 01.000 4 7 2Trnl 1 27 4Trn30 107543 7 32 27 17 3561t 465 145 241 I 5.65 6.62 0.000 5 4 lTrn3_ 7 2Trnill 3921 4 1 7 32 36f665 465 465 241 5.63 6.62 0.002 6 10 5Trn 1- 19 2Trn2l 24a,706 10 67 19 20 15935 389 359 198 3.84 4.17 0.001 7 1 Trn2 Tl 6 lTrn 1. 70 1 1 6 4 49693 526 526 274 7.78 9.60 D.002 5 2 Trn2 T2_ 19 2Trn21_ 2028 2 1 19 20 25423 389 389 198 3.64 4.17 0.011 9 12 Tfrn 1I- 19 2Trn2i_ 391806 12 30 .19 20 13983 3&9 359 198 3.84 4.17 0.001 10 .1 Trn2_Ti1 9 4Trnll 161 1 1 9 1 47005 434 434 223 4.34 5.48 01.001 11 4 1Trn3_ 11 6Trnl 11 5546 4 1 11 1 35655 348 345 176 3.11 3.25 01.001 12 1 Trn2_TI_ 5 2Trn3_ 56 1 1 5 42 44974 549 549 267 8.76 11.05 0.017 13 4 lTrn3 5 2Trn3_ 3475 4 t1 5 42 44974 549 549 287 6.76 11.05 0.033 14 4 iTrn3_ 24 1Trn30_ 10815 4 1 24 1 44912 549 549 287 8.76 11.05 01.000 15 4 ITrn3_ i 15 Trn21_ 1016 4 1 18 1 44912 549 549 257 6.76 11.05 U..013 16r 17 3Trn14_ 18 1Trn21_ 53601 3 17 111 16 1 44596 549 549 287 8.76 11.05 .0.000 17 15 lTrn2i_ 20 3Trn21 571713 18 1 20 39 43605 549 549 287 8.76 11.05 0.029 15 19 2Trn21 20 3Trn21 573512 19 1 20 39 43426 549 549 297 6.76 11.05 0c.011 19 3 Trn2 T3 19 2Trn21_ 3151 3 1 1,9 1 43219 549 549 287 8.76a 11.05 01.010 524 273 7.70 49 0.001 20 3 Trn2 T3 14 9Trnll_ 296-5 3 1 14 155 43405 524 21 3 Trn2 T3 15 lTrn14 2979 3 1 15 1 42722 526 526 274 7.75 9.60 0.000 22 3 Trnm2T3 16 , 2Trn 14_ 2953 3 1 16 1 41044 524, 524 273 7.70 9.89 01.000 Total. U = 0.140 Notes: 1.Tv,,., is the maximum temperature of the two paired load states, and represents the metal (nodal) temperature at the location Overall Fen 8.20 being analzed. This, which is include-d as 'T in the'Transient Maximum Temperatures7' table above. determined from the VESLFAT

2. F, values computed using the low alloy steel equation from Section 3.0 of Reference [61 with S' conservatively set to a maximum value of 0.0 15. and the transtformed strain rate conservat~rely set to a minimum value of In (0.00t1) = 508 for all load
3. U*, = [U x HWC F, x % HWCI [U x NWC F_. x % NWC1.
4. T1 and 72 represent the load number for Load #1 and Load #2, respectively, and sl and s2 represent the state number for each
5. For each load pair, nj is the number of available cycles for Load #1, n- is the number of available cycles for Load #2, and n is the available number of cycles for the load pair (i.e., the minimum of nj and n.).

File No.: 0801038.303 Page 17 of 18 Revision: 1 F0306-OI RO

SStructuralIntegrity Associates, Inc.

Table 10: Linearized Stress Files Compiled for VY-StressResults.xls Filename Description vyl 6qtran2-s.csv Transient 2 linearized stress vyl 6q_tran3-s.csv Transient 3 linearized stress vy_l 6q_tranl 1-s.csv Transient 11 linearized stress vyl 6q_tran 14-s.csv Transient 14 linearized stress vyl 6q_tran21-23-s.csv Transients 21-23 linearized stress vyl 6q_tran24-s.csv Transient 24 linearized stress vyl 6q_tran30-s.csv Transient 30 linearized stress Note: All files are from the supporting computer files associated with Reference [1].

File No.: 0801038.303 Page 18 of 18 Revision: I F0306-OIRO

StructuralIntegrity Associates, Inc. File No.: 0801038.304 CALCULATION PACKAGE Project No.: 0801038 Quality Program: Z Nuclear [ Commercial PROJECT NAME:

VY Confirmatory Analysis for CS and RO Nozzles CONTRACT NO.:

10163217 Amendment 5 CLIENT: PLANT:

Entergy Nuclear Operations, Inc Vermont Yankee Nuclear Power Station CALCULATION TITLE:

Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle Document Affected Project Manager Preparer(s) &

Documen afe Revision Description Approval Checker(s)

Revision Pages Signature & Date Signatures & Date 01 - 20, Initial issue. Preparers:

Appendix: Gary L. Stevens Michael J. Minard A- I - A-23 01/07/09 01/07/09 Computer files. Tyler D. Novotny 01/07/09 Checker:

Terry J. Herrmann 01/07/09 1 1-8,10,11, Revised per summary. / Preparer:

13-20, contained in Section 1.1. 0(,. 11Z64-A-2 Changes are marked with "revision bars" in Gary L. Stevens right-hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker:

William Weitze 03/09/09 Page 1 of 20 F0306-01 RO

StructuralIntegrity Associates, Inc.

Table of Contents 1.0 OBJECTIVE ............................................................................................................ 4 1.1 Changes M ade in Revision 1 of this Calculation .......................................... 4 2.0 M ETHODOLOGY ................................................................................................... 4 3.0 ASSUM PTIONS / DESIGN INPUTS ....................................................................... 5 3.1 Assumptions ............................................................................................... .. 5 3.2 ASM E Code Edition ..................................................................................... 5 3.3 Transients ...................................................................................................... 6 3.4 Heat Transfer Coefficients ............................................................. ...... 6 3.5 Finite Element M odel .................................................................................. 8 3.6 Nozzle Blend Radius Pressure Stress .......................................................... 8 3.7 Piping Interface Loads............................................................................... ......... 8 3.8 SCFs, Safe End ............................................................................................ 9 3.9 Environmental Fatigue M ultipliers ................................................................ 9 4.0 CALCULATIONS ............... .................................................................................. 13 4.1 Piping Interface Loads .................................... 13 5.0 RESULTS OF ANALYSIS ..................................................................................... 18

6.0 REFERENCES

........................................................................................................ 19 APPENDIX A: ANSYS INPUT FILE: RON VY.INP ................................................. A-1 FileNo.: 0801038.304 Page 2 of 20 Revision: 1 F0306-01!

VStructural integrity Associates, Inc.

List of Tables Table 1: Vessel and Nozzle/Safe End Transients ............................................................. 10 Table 2: H eat Transfer Coefficients ....................................................................................... 11 Table 3: Temperature-Dependent Material Properties ........................................................... 11 Table 4: Recirculation Outlet Nozzle Attached Piping Loads and Dimensions [9, 11] ......... 14 Table 5: Membrane Plus Bending Stresses Due to Piping Loads .................................... 14 Table 6: 0% Flow Regions I and 3 Heat Transfer Coefficients ....................................... 15 Table 7: 0% Flow Region 5 Heat Transfer Coefficient ................................................... 16 List of Figures Figure 1: Nozzle and Vessel Wall Thermal Boundaries ................................................... 12 Figure 2: Coordinate System for Forces and Moments ..................................................... 17 Figure 3: RO Nozzle and Safe End Geometry [20] .......................................................... 17 File No.: 0801038.304 Page 3 of 20 Revision: 1 F0306-01I

VStructural Integrity Associates, Inc.

1.0 OBJECTIVE The objective of this calculation package is to establish the design inputs and methodology to be used for an ASME Code,Section III fatigue usage calculation of the reactor pressure vessel (RPV) recirculation outlet (RO) nozzle at Vermont Yankee Nuclear Power Station (VYNPS) 1 .

This calculation, along with subsequent calculations for stress and fatigue, are being performed to assess the impact of using finite element analysis using all six components of stress in lieu of the Green's Function approach used in SI project VY-16Q [4, 7, and 11]. Therefore, to the extent possible, inputs from that project will be maintained and used.

1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:

a. Transient 9 described in Table 1 was changed to more precisely match the Green's Function analysis.
b. All remaining changes marked throughout this calculation are editorial changes made to the text of the calculation package.

2.0 METHODOLOGY A detailed fatigue usage calculation of the RO nozzle will be performed using the methodology of Subarticle NB-3200 of Section III of the ASME Code [1]. The 1998 Edition includingthe 2000 Addenda of the ASME Code [10] is also used for material properties. Only the fatigue calculation portion of the ASME Code methodology will be used and the analysis will be a fatigue assessment only, not a complete ASME Code analysis.

Finite element analysis will be performed using a previously-developed axisymmetric finite element model (FEM) of the RO nozzle [7]. Thermal transient analysis will-be performed using the FEM for each defined transient. Concurrent with the thermal transients are pressure and piping interface loads; for these loads' unit load analyses (finite element analysis for pressure, and manual calculations for piping loads) will be performed. The stresses from these analyses will be scaled appropriately based on the magnitude of the pressure and piping loads during each thermal transient, and combined with stresses from the thermal transients. Other stress concentration factors (SCFs) will be applied as appropriate.

All six components of the stress tensor will be used for stress calculations. The stress components for the non-axisymmetric loads (shear and moment piping loads) can have opposite signs depending upon which side of the nozzle is being. examined. Therefore, when combining stress components from these loads with stress components from thermal transients and other loads, the signs of the stress components will be adjusted to maximize the magnitude of the stress component ranges. The fatigue analysis will be performed at locations that were determined in a previous calculation [4]. Stresses will be linearized at these locations.

The methodology described and applied herein and in the two additional recirculation outlet nozzle fatigue calculations is in accordance with the approach used in the SIA calculations for the feedwater nozzle [16, 17, 18] and contains no significantly different scientific or technical judgments used in those calculations.

File No.: 0801038.304 Page 4 of 20 Revision: 1 F0306-01:

StructuralIntegrityAssociates, Inc.

The linearized primary plus secondary membrane plus bending stress will be used to determine the value of Ke to be used in the simplified elastic-plastic analysis in accordance with ASME Code NB-3200 methodology. Environmental fatigue multipliers will be applied in accordance with NUREG/CR-6583 [2]

for the low alloy steel forging and NUREG/CR-5704 [15.] for the stainless steel safe end.

3.0 ASSUMPTIONS / DESIGN INPUTS 3.1 Assumptions

1. Extended power uprate (EPU) effects are considered as being applied to the entire 60-year period of operation. The higher pressures, flows, and temperatures at uprate conditions are used in determining and applying heat transfer coefficients [4, Section 3.2] [11, Section 4.1].
2. The Boltup transientdoes not affect the RO nozzle because there is no pressure or temperature change, and the nozzle is sufficiently removed from the vicinity of the flange such that stresses due to head stud tensioning are insignificant at the nozzle location [8]. The Boltup transient is therefore excluded from the transients analyzed.
3. For the blend radius and safe end transient definitions, steady state condition time steps were assumed to be 5,000 seconds for Transients 3, 5, 6, 8, 9, and 40,000 seconds for Transients 1, 2, 4, 7, 10.
4. The effect of non-uniform geometries is judged to be insignificant for flow inside the safe end, because of the smooth transition and small, geometry changes, as shown in Figure 3. The nominal inner diameter for all heat transfer regions was used to calculate heat transfer coefficients.
5. Density, p, and Poisson's ratio, v, used in the FEM are assumed typical values of p = 0.283 lb/in 3 and v = 0.3, respectively.
6. For purposes of linearizing stress at the nozzle blend radius, the cladding is ignored'.
7. Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 707F and the full values are reached at reactor design temperature, 575°F, as was done in the previous analysis [11, Section 3.4].
8. Consistent with Reference [4], 12% of the available temperature difference (AT) between the fluid and surface was assumed for all natural convection thermal heat transfer coefficients.
9. The instant temperature change for transients is assumed as a 1-second time step.

3.2 ASME Code Edition The analysis will be performed in a manner consistent with the fatigue usage rules in NB-3200 of Section III of the ASME Code; the 1998 Edition with Addenda through 2000 [1] will be used, for consistency with the previous analysis [11].

File No.: 0801038.304 Page 5 of 20 Revision: 1 F0306-01I

VStructural integrity Associates, Inc.

3.3 Transients Previously developed thermal and pressure transients [11 Tables 2 and 3] are used for this analysis. The transients to be evaluated are shown in Table 1. For each transient, the time, nozzle fluid temperature, RPV pressure, percent reactor recirculation flow rate, and number of cycles are included. In some cases, flow rates and nozzle temperature values from the nozzle thermal cycle diagram [8, Attachment 1, p. 4] are used' to reduce excess conservatism. Note that the only difference between the vessel and the safe end/nozzle transients is the temperature difference between the two regions for Transient 9.

At the inside surface of the RPV, the Region B or BI bulk fluid temperature from the reactor thermal cycle diagram [8, Attachment 1, p. 2] shall be applied.

3.4 Heat Transfer Coefficients Heat transfer coefficients are calculated at 300' F, as in the previous analysis [4]. The heat transfer coefficients for the 100% flow and 50% flow cases were calculated from Reference [5] as follows:

K =0.8 ( 0.2 S3 h°-25 DDf Where:

hDf= the heat transfer coefficient at a Diameter and flow rate h 300 = the heat transfer coefficient from Reference [5] at 300°F,f= 25 ft/sec, and D= 26" =,4,789 BTU/hr-ft2_OF fif= the flow velocity corresponding to hDf (ft/sec)

DDf= the diameter corresponding to hDf(in)

The heat transfer coefficients for 0% flow were calculated in spreadsheet HTCOEF.xls for natural convection and are shown in Tables 6 and 7.

As shown in Figure 1, the following heat transfer coefficients were applied:

Region 1 The heat transfer coefficient, h, for 100% flow is 4789 17-36) "82-0.82 =3583 BTU/hr-ft2-°F at 300TF, where 17.364 ft/sec is converted from 28,294 GPM and 25.8 in ID [20].

The heat transfer coefficient, h, for 50% flow is 4789 -

(8.6821~0(

-

26 J

>0.2

= 2058 BTU/hr-ft2 -

'F at 300TF, where 8.682 ft/sec is converted from 14,147 GPM and 25.8 in ID [20].

The heat transfer coefficient, h, for 12% flow is 4789 (-2.084) 08 26 0.82 =657 BTU/hr-ft2-°F at 300'F, where 2.084 ft/sec is converted from 3,395 GPM and 25.8 in ID [20].

FileNo.: 0801038.304 Page 6 of 20 Revision: I F0306-01

VStructural Integrity Associates, Inc.

The heat transfer coefficient, h, for 0% flow is 112 BTU/hr-ft 2-°F at 300'F. (Table 6, for natural convection)

Region 2 The heat transfer coefficient for Region 2 is linearly transitioned from the value of the heat transfer coefficient used in Region I to the value used for Region 3.

Region 3 (the point between Region 2 and Region 4)

The inside diameter of Region 3, as measured on the ANSYS model, is 35.49 inches.

The heat transfer coefficient, h, for 100% flow is 4789 (9.176_0.g (26 ) 2018 BTU/hr-ft2-25__ 35.49 OF at 300'F, where 9.176 ft/sec is converted from 28,294 GPM and 35.49 in. ID.

The heat transfer coefficient, h, for 50% flow is 4789 4.5) 08 26 0.2 = 1159 BTU/hr-ft2-

___25 35.49)I OF at 300TF, where 4.588 ft/sec is converted from 14,147 GPM and 35.49. in. ID.

. for 12% flow is 4789 \ ~~~~25 The heat transfer coefficient, h, ) 35-.49 =7BU/-f2°

- 370 BTU/hr2ft -.F at 300°F, where 1.101 ft/sec is converted from 3,395 GPM and 35.49 in. ID.

The heat transfer coefficient, h, for 0% flow is 112 BTU/hr-ft2-°F at 300'F. using the same HTC as Region 1 (Table 6, for natural convection)

Region 4 The heat transfer coefficient for Region 4 (Nozzle Blend Radius).is linearly transitioned from the value of the heat transfer coefficient used in Region 3 to the value used in Region 5.

Region 5 A value of 0.5 x Region 1 HTC from Reference [5, page I-T9-4, 6] is used to simulate the interior of the RPV shell for all conditions.

The heat transfer coefficient, h, for 100% flow is 0.5 x 3583.3 = 1,792 BTU/hr-ft 2-OF at 300 0 F.

The heat transfer coefficient, h, for 50%flow is 0.5 x 2058.1 1029 BTU/hr-ft2-OF at 300 0 F.

The heat transfer coefficient, h, for 12% flow is 0.5 x 657.2= 329 BTU/hr-ft 2-OF at 300 0F.

The heat transfer coefficient, h, for 0% flow is 101 BTU/hr-ft 2 -OF at 300°F. (Table 7, for natural convection) by using 40 in. hydraulic diameter [5].

File No.: 0801038.304 Page 7 of20 Revision: 1 F0306-011

StructuralIntegrity Associates, Inc.

Region 6 The heat transfer coefficient, h, is 0.4 BTU/hr-ft2 -OF [5].

A summary of the heat transfer coefficients (HTC) to be used is shown in Table 2.

3.5 Finite Element Model The ANSYS program [6] will be used to perform the finite element analysis. A previously developed axisymmetric model will be used [7, file RONVYINP], except that temperature-dependent material properties will be used. Table 3 shows the applicable material properties [10].

Stresses will be extracted and linearized at two locations, both on the inside surface of the model, one at the safe end, and one at the blend radius, as was done previously [4].

3.6 Nozzle Blend Radius Pressure Stress The axisymmetric model has the effect of modeling the cylindrical RPV as spherical. The following paragraphs describe the details of the modeling used to account for the differences in this approximation and the actual geometry of two intersecting cylinders.

The radius of the vessel in the finite element model was multiplied by a factor of 2 to account for the fact that the vessel portion of the axisymmetric model is a sphere, but the true geometry is a cylinder. The equation for the membrane hoop stress for a sphere is:

(pressure) x (radius) 2 x thickness The equation for the membrane hoop stress in a cylinder is:

(pressure)x (radius) thickness The factor of two was verified in Reference [4], where actual stress results were compared to the results of this analytical form.

The pressure stress components for the safe end and blend radius paths will be extracted using ANSYS [6].

3.7 Piping Interface Loads Per Reference [9, 11], the RO nozzle piping loads, which conservatively use the design loads for the seismic, thermal and deadweight load combination, are stated in Table 4 along with relevant dimensions.

The coordinate system used for these are shown in Figure 2 and is consistent with Reference [9]. The finite element model coordinate system is shown in Figure 1.

File No.: 0801038.304 Page 8 of 20 Revision: 1 F0306-01

StructuralIntegrityAssociates, Inc.

3.8 SCFs, Safe End At the safe end inside surface, guidance is taken from the piping analysis rules in Subarticle NB-3600 of Section III of the ASME Code [1]. The stresses caused by the piping will be hand calculated and require a stress concentration factor, if appropriate. The stress concentration factor for the safe end location is 1.53 [5, page I-S9-4E, Table 5]. This value is conservatively used for both the C 2 and K2 values required by the ASME code [1, NB-3600]. The piping loads are relatively minor in comparison to the other loads this nozzle experiences so the conservative C2 and K 2 values will have a small impact on the analysis.

These factors are conservatively applied to all six components of the stress tensor.

3.9 Environmental Fatigue Multipliers The environmental fatigue multipliers for the safe end will be calculated in accordance with NUREG/CR-5704 methodology [15], and the environmental fatigue multipliers for the nozzle blend radius will be calculated in accordance with NUREG/CR-6583 methodology [2].

File No.: 0801038.304 Page 9 of 20 Revision: 1 F0306-01.

Structural IntegrityAssociates, Inc.

Table 1: Vessel and Nozzle/Safe End Transients Transient Time Temp Time Step Pressure Flow Rate Transient Time Temp Time Step Pressure Flow Rate Number LS L U *psg)

La} (GPMI Number JLM

("F L"s Lpsi (GPM)

1. Normal Startup with 0 100 0 14147.0 6. Reactor Overpressure 0 526 1010 28294 0

Heatup at 10 *F/hr 16164 549 16164 1010 (50%) 1 Cycle (1,2) 2 526 2 1375 (100%)

300 Cycles (2) 56164 549 40000 1010 32 526 30 940

2. Turbine Roll and 0 549 1010 28294 1832 526 1800 940 Increase to Rated Power 1 542 1 1010 (100%) 2252 549 420 1010 300 Cycles (1, 2) 601 542 600 1010 2312 549 60 1010 602 526 1 1010 2313 542 1 1010 40602 526 40000 1010 1 2913 542 600 1010
3. Loss of Feedwater 0 526 1010 28294 2914 526 1 1010 Heaters 1800 542 1800 1010 (100%) 7914 526 5000 1010 Turbine Trip 25% Power 2100 542 300 1010 7. SRV Blowdown 0 526 1010 28294 10 Cycles (2) 2460 526 360 1010 1 Cycle (2) 600 375 600 170 (100%)

3060 526 600 1010 11580 70 10980 50 3960 542 900 1010 51580 70 40000 50 4260 542 300 1010 8. SCRAM Other 0 526 1010 28294 6060 526 1800 1010 228 Cycles (1, 2) 15 526 15 940 (100%)

11060 526 5000 1010 1815 526 1800 940

4. Loss of Feedwater 0 526 1010 0 2235 549 420 1010 Pumps 3 526 3 1190 (0%) 2295 549 60 1010 10 Cycles (1,2) 13 526 10 1135 2296 542 1 1010 233 300 220 1135 2356 542 60 1010 2213 500 1980 1135 2357 526 1 1010 2393 300 180 885 7357 526 5000 1010 6773 500 4380 1135 9. Improper Startup 0 526 1010 3395 7193 300 420 675 14147 1 Cycle (1, 2) 1 130O 1 1010 (12%)

7493 300 300 675 (50%) 27 130 26 1010 11093 400 3600 240 28 526 1 1010 16457 549 5364 1010 5028 526 5000 1010 16517 549 60 1010 10. Shutdown 0 549 1010 14147 16518 542 1 1010 28294 300 Cycles (2) 6264 375 6264 170 (50%)

17118 542 600 1010 (100%) 6864 330 600 88 17119 526 1 1010 16224 70 9360 50 57119 526 40000 1010 56224 70 40000 50

5. Turbine Generator Trip 0 526 1010 28294 11. Design Hydrostatic -- 100 0 1981 60 Cycles (1, 2) 10 526 10 1135 (100%) Test 1100 (7%)

15 526 5 1135 120 Cvcles (2) 50 30 526 15 940 12. Hydrostatic Test - 100 - 50 1981 1830 526 1800 940 1 Cycle (2) I ______ j 15633 50 ____

(7%)

549 420 1010 _________________ _____

2250 2310 549 60 1010 2311 542 1 1010 2911 542 600 1010 2912 526 1 1010 7912 526 5000 1010

1. The instant temperature change is assumed as 1-second time step.
2. The number of cycles is for 60 years [8].
3. 130'F is the Region I temperature for Transient 9, whereas the blend radius is at 268°F and the vessel is at 2687F, as was modeled previously [ 11].

File No.: 0801038.304 Page 10 of 20 Revision: 1 F0306-01

VStructural IntegrityAssociates, Inc.

Table 2: Heat Transfer Coefficients Flow Rate Thermal Region 100% 50% 12% 0% (Natural 1 Convection)

Region 1 3583 2058 657 112 Region 2 Linear transition from Region 1 and Region 3 values Region 3 2018 1159 370 112 Region 4 Linear transition from Region 3 and Region 5 values Region 5 1792 1029 329 101 Region 6 0.4 for all flow rates Note: All Heat transfer coefficients are in units of BTU/hr-ft2 -°F and are evaluated at 300'F.

Table 3: Temperature-Dependent Material Properties Mean Young's Coefficient of Conductivity, Specific Heat, Diffusivity, Material Tempera- Modulus, Thermal k cp Description ture, *F E x 106 d No. Expansion, (BTU/hr-ft-°F) (BTU/ibm-*F)

(ft2/hr)

(psi) ax 10,6 (see Note 1) (see Note 4)

(in/in- 0 F) 4 SA533 Grade B, 70 29.2 7.0 23.5 0.458 0.105

[Vessel Wall] .200 28.5 7.3 23.6 0.425 0.114 (Mn-1/2AMo-1/2/2Ni) 300 28.0 7.4 23.4 0.401 0.119 400 27.4 7.6 23.1 0.378 0.125 500 27.0 7.7 22.7 0.356 0.130 600 26.4 7.8 22.2 0.336 0.135 2 SA-508 Class 2 70 27.8 6.4 23.5 0.458 0.105

[Nozzle Forging] 200 27.1 6.7 23.6 0.425 0.114 300 26.7 6.9 23.4 0.401 0.119 400 26.1 7.1 23.1 0.378 0.125 500 25.7 7.3 22.7 0.356 0.130 (See Note 2) 600 25.2 7.4 22.2 0.336 0.135 1,3 SA 240 Type 70 28.3 8.5 8.6 0:151 0.116 304, SS Clad, 200 27.6 8.9 9.3 0.156 0.122 SA 182 Type 300 27.0 9.2 9.8 0.160 0.125 F316 400 26.5 9.5 10.4 0.165 0.129

[Clad, Safe End] 500 25.8 9.7 10.9 0.170 0.131 (see Note 3) 600 25.3 9.8 11.3 0.174 0.133 Notes: 1. Convert to BTU/see-in-°F for input to ANSYS.

2. Properties of A508 Class II are used (3/4Ni-I/2Mo-1/3Cr-V).
3. Properties of 18Cr - 8Ni austenitic stainless steel are used.
4. Calculated as [k/(pd)]/122.

FileNo.: 0801038.304 Page 11 of 20 Revision: I F0306-01I

V Structural Integrity Associates, Inc.

AFLEAS 10*.T NULN APP, 19 2007 13:35:14 Region 5 Region 6 Region 4 RegRion 2 Region 1 Region 3 x

Recirc Outlet Nozzle Finite Element Model Figure 1: Nozzle and'Vessel Wall Thermal Boundaries File No.: 0801038.304 Page 12 of 20 Revision: 1 F0306-01

VStructural IntegrityAssociates, Inc.

4.0 CALCULATIONS 4.1 Piping Interface Loads From general structural mechanics [14], the membrane plus bending stresses at the inside surface of a thick-walled cylinder are:

az, = axial stress due to axial force = Fz/A cz, = axial stress due to bending moment = Mxy(ID/2)/I cz = czI + cyz2 TrO =.shear stress due to torsion = Mz(ID/2)/J Trz = shear stress due to shear force = 2Fxy/A, where F,, Fy, Fz, Mx, My, and M, are forces and moments at the pipe-to-safe end weld MxL = moment about x axis translated by length z = -L = M, - Fy L MyL = moment about y axis translated by length2 z0 =5 -L = My + Fx L Mxy = resultant bending moment2 = (MxL2 + MyL )

Fxy = resultant shear force = (Fx F y2)0'5 ID, OD = inside and outside diameters A = area of cross section = (n/4)(OD 2 - ID 2)

I = moment of inertia = (ir/64)(OD4 - ID 4)

J = polar moment of inertia = (70/32)(0D 4 - ID4)

The shear stresses are expressed in a local coordinate system with r radial (X in ANSYS coordinates), 0 circumferential (Z in ANSYS coordinates), and Z axial (Y in ANSYS coordinates). Tables 4 and 5 show the calculation of stresses; ID, OD, and L are taken from the previous piping load stress calculations [11, Section 3.4]. Forces and moments are taken from Reference 11, Table 1. Note that the IDs shown in Table 4 for the safe end and nozzle blend radius (25.938" and 37.368", respectively) represent the two most limiting locations for the nozzle (See Figure 3), and therefore do not represent the ID values where the HTCs were calculated.

File No.: 0801038.304 Page 13 of 20 Revision: 1 F0306-01:

StructuralIntegrityAssociates, Inc.

Table 4: Recirculation Outlet Nozzle Attached Piping Loads and Dimensions [9, 11]

Safe End Nozzle Blend Radius Fx, kip 20.0 20.0 Fy, kip 20.0 20.0 F,, kip 30.0 30.0 Mx, kip-in 2004.0 2004.0 My, kip-in 3000.0 3000.0 Mz, kip-in 2004.0 2004.0 L, in 4.25 42.77 OD, in 28.38 55.88 ID, in 25.938 37.368 Table 5: Membrane Plus Bending Stresses Due to Piping Loads Safe End Blend Radius MxL, kip-in 1919.00 1148.60 MyL, kip-in 3085.00 3855.40 Mxy, kip-in 3633.15 4022.86 F,,, kip-in 28.28 28.28 A, in2 4 104.18 1355.76 I, in 4 9624.85 382912.48 J, in 19249.69 765824.95 UYzi, ksi 0.288 0.022 az, ksi 4.895 0.196 cz, ksi 5.183 0.218

'rrO, ksi 1.350 0.049 Tz, ksi 0.543 0.042 FileNo.: 0801038.304 Page 14 of 20 Revision: 1 F0306-01.

V StructuralIntegrity Associates, Inc.

Table 6: 0% Flow Regions 1 and 3 Heat Transfer Coefficients Pipe Inside Diameter, D =: L.. inche- = 2.150 ft

\ ' 0.655 mn Outer Pipe, Inside radius, r.=, 12.9 inches = 1.075 ft 0.328 m Inner Pipe Outside Diameter, D inches 0.000 ft

-" 0.000 mi Inner Pipe, Outside radius, r, = 0 inches 0.000 ft 0.000 m Fluid Velocity, V = 0.000 Itsec

  • eOoo*' gpm= 0 . rlb/br Characteristic Length, L = D = r 2.150 ft = 0.655 m T.. --.. AT : assumed to be 12% of fluid temperature = 0.40 8 12.00 r 24.00 36.00 40.00 60.00 72.00 "F

= 4.67 6.67 13.33 20.00 26.67 33.33 40.00 TC Value at Fluid Temperature. T [121 Units Conversion 70 100 200 300 400 500 600 F Water Property Factor [19] 21.11 37.78 93.33 148.89 204.44 260.00 315.56 2C k 1.7307 0.5997 0.6300 0.67B4 0.63,- 0.6611 0.6040 0.5071 W/rr-C

...... ........................................................................

....

(Termal .................

Conductivity) ...... k*......... 0.3640 0.3465 *..........o:

...................

0.30920 0.3950s ".........:*0.382D.*............*.o.

0.3490 .........

2 o .........

02930 f .L.r.:.-.'...

Btulhr-ft-'F c; 4.109 4.165 4,179 4.229 4.313 4.522 4.902 6.322 kJlkg-=C

~ ~~~ ~

~ (Seii~a)1.000

............. ~~~~~~~~-09

~ ~ ~s!!.e.t...........................o........... ........ ...

oo.........1.030 1.010 o.3.o......... 1,080 .........1.190

........ =.9o....  !.=o. ..............

.......1.510 u..........

Btu/Ibnn.F 97.1 004.7

.916.01 982.7 917.6 650.6 784.9 679.2 t'gIm3

.o*. *.......................... ...........................

................. (Density) *62.3

..............

. .. 60.1,:................ 57.3

. 662.1:............ ........... . 5............

53.6 f49.0.o..................

. .... 42.4............ *.. ..........

lbrnift 1.8 1.896E-04 3.24E-04 6.66E-04 1.016-03 1.40E-03 1.90E-03 3.15E-03 n*i:'_C

.....f(Volumetric:

.o........ * .o.t

....

Rate Iof Expansion).

..

  • n....

.... ..... ........................... ....1:05E-04

,.o o.f...... ......................................................

1.80E-04 3.70E-04 15.60E-04 * .. .........

7.800E-04 o*..

1.10E-03  ?*........ !.*........

1.756E-03 . ..F*...

........ .*.felft- ---..

1 0.3046 9.006 9.80f 9.,06 9.806 9.306 9.606 ME.606 Ms (Gravitational Constant) 32.17 32.17 32.17 32.17 :32.17 32.17 32.17 *s; M 1.4681 9.86E-04 6.926-04 3.07E-04 1.93E-04 1.38-04 1.04E-04 8.62E-015 lgm-s

...................*t V...o...................

(Dy~namic Viscosity) ........................... ....**EO. ....................

6.869-04 4.58E-04 0..-...

...............

2.06E-04 .*O................O-.

1.306-04 9.306-05 7.O.................

.......

7.006-05 SZ*.5.

5.796-05......... lbnrdft-s 0.......

.....

Pr 6.980 4.510 1.910 1.220 0.950 0.859 1.070 -

(Prandtl Number)

Calculated Parameter Formula 70 100 200 300 4S0 500 T00 ReynoldMs Number, Re pVO/ft 0 0 0 0 0 0 0 -

GrasheofNumber. Gr gATL-/(Ip} 2441754517 1.2,97E+10 2.417E÷11 1.252E+12 3.9768E+12 1.034-+13 2.16049E+13 -

Grashof Number, Gr, gAAT(r.-rj)-'/(u~p- 3.05E+08 1.506+D9 3.026+10 1.576+11 4.97E+11 1.29E612 2.70E+12 -

Rayleigh Number. Ru GrPr 170434-46531 5.7265E÷10 4.616.+11 1.528ME12 3.77770+12 8.8836+12 2.311726+13 -

Rayleigh Number, Ru GrPr 2.1356-09 7.16E+09 5.77E+10 1.91E611 4.72E+11 1.116+12 2.696.12 -

From [19):

Inside Surface NaturalConvection Heat TransferCoefficient:

Case: Enclosed cylinder C n==fl n'0.55l H*, C(OrPr)7'IL 181.85 258.65 46934 637.80 7"/'73.57 875.17 933.22 Wnr-'C 32.03 45.55 82.66 ,i-,112.34U,. 136.24 154.13 164.35 Btufhr-ft:-*F FileNo.: 0801038.304 Page 15 of 20 Revision: I F0306-01.

VStructural IntegrityAssociates, Inc.

Table 7: 0% Flow Region 5 Heat Transfer Coefficient Pipe Inside Diameter, D = .40..O0OW?Ž inches = 3.333 ft

= 1.016 m Outer Pipe, Inside radius, r, = 20 inches = 1.667 ft 0.508 m Inner Pipe Outside Diameter, D = inches = 0.000 ft

= 0.600 m Inner Pipe, Outside radius, r, = 0 inches = 0.000 ft 0.000 m Fluid Velocity, V = 00,00 fusec 0 D pm= 0 Mitlhr Characteristic Length, L = D = 3.333 ft = 1.016 m T_ T Lt = assumed to be 12% of fluid temperature = 0.40 12,00 24.00 3M.00, 46.00, 60.00 72.00 'F 4.67 6.67 13.33 20.00 25.67 33.33 40.00 =C Value at Fluid Temperature, T [121 Units Conversion 70 100 200 300 400 000 600 'F Water Property Factor [19] 21.11 37.78 93.33 140.89 204.44 260,00 3105.6 'C k 1.7307 0.5997 0.6300 0.6784 0.6636 0.6M11 0.6040 0.5071 W/M-lC

...................... *. . ).

. .. cConductivity)

.(Thermal ............................................. o0.a4605  :** o..........:*.*.........z*

... ..................

0.36.40 ...........0.3020 0.39500. ........

0.3E20Lo 0.3.* . ..............

........

....

0.3490 0.29300 . * ........

  • ~,

.........  :. .:

tu/tir-ft-'F

c. 4.1069 4.185 4.179 4229 4.313 4.522 4.002 6.322 Ij/Vg-'C

...................... Heat)

(Specific................................ 1.000 0.990 1.010 1.030

...................................................................................................... 1.050 1.190

  • ........................... Btu'lbm-'F 1.510 ........................

O 16.018 997.1 994.7 S62.7 917.8 056.6 784.0 679.2 kginý (Density) 62.3 62.1 60.1 57.3 5316 49.0 42.4 lbn~fe

,-- 1.0 -:24- 1.0E-04 6..66-04 1.01E-03 1.400-03 1.9-SE3. 3.15E-03 m r/m,C (Volumetric Rate of E*pansion) 1.05E-04 1.00E-04 3.730-34 5.605-04 7.80E-04 1.1OE-03 1.7zE-03 '/f-=F 9 0.3042 9.5,06 9.006 .9.006 9.006 9.806 9.805 9.606 tV':

(Graygaittinal

....................... Constant)

/4"...........1.

..................... 14...........

S 32.17 E0 32.17 2 -4 30 32.17 6 0 .32.17 3 -4

..... .......................................................................

99 1.32.17 32.17E-E-4"..................................1.

,.....":" is.

32.17 ..... ..................

A1.4081 9.96E-114 6.82f-04 3.07E0-4 1.93E-04 1.38E-04 1.0,4E-D4 8.62E-05 kg~nm-s 1.30E-04 9.300-05 1.19E-01 infft-s

. .P....

... ..Viscosity) namic r .......................................... 6.69E-04 6............. 4.56E0-4

"...1"..........

.......... 2.06E--04

....... *b Y* *

......... 6* "........7.00--05

.......... "7*.......... ....  ;*.............. .............

Pr6.900 4.5110 1.910 1.220 0.9150 0.659 1.00 (Prandtl Number)

Calculated Parameter Formula 70 100 200 300 400 500 600 'F Reynold's Number, Re pVDat 0 0 0 0 0 0 0 GrashofNumb*er, Or g*ATL=/r4p}u 90S'9,61160- 4.73190410 9.006E011 4.667E.ý12 1,.461S9E'13 3.854E+13 6.05143E+13 --

Grashof Number, Gr, gALT(rr,-?/(ta)a 1.14E49 5.915049 1.13E011 5.083011 1.85,+12 4.825-12 1.01E-13 -

Rayleigh Number, Ra GrPr 63515209008 2.134t1611 1.72E-12 5.69305÷12 1,40755413 3.315013 8.61503E+13 -

Rayleigh Number, Ra Gr5 Pr 7.94E01- 2.67E+10 2.15E-11 7.12E011 1.76E+12 4.145-12 1.08E+13 -

From f191:

Inside Surface Natural Convection Hleat Transfer Coefficient:,

Case: Enclosed cylinder C= n (1 -. ,.-3-°' .*)-." .

H. . C(GrPrY65WL 162*97 231.79 420.60 571.E6 ' 693.25 704.30 836.32 W .r.--C 2&.70 40.82 74.07 .103.6.O . 122.09 138.13 147.29 Btu/hr-ft:_F File No.: 0801038.304 Page 16 of 20 Revision: 1 F0306-01

StructuralIntegrity Associates, Inc.

I+

, "* I .- "-,- - _

tMz Y, S7Z Z

Figure 2: Coordinate System for Forces and Moments SST CLAD 103.00 R MIN LOW ALLOY

- STEEL NOZZLE REPLACEMENT PIPE SA 508 CL IIt SUPPLIED BY OTHERS 2.50 R ,

I25.40 MIN 0 25.93 '_:'0, NOTE: NOZZLE DIMENSIONS ARE REFERENCE DIMENSIONS IN INCHES 14 -EXISTING SST (308 LI OVERLAY Figure 3: RO Nozzle and Safe End Geometry [201 File No.: 0801038.304 Page 17 of 20 Revision: I F0306-01

StructuralIntegrity Associates, Inc.

5.0 RESULTS OF ANALYSIS This calculation package specifies the ASME Code Edition, finite element model, thermal and pressure transients (Table 1), and HTCs (Table 2) to be used in a fatigue usage calculation of the RO nozzle at Vermont Yankee. Thermal transient and pressure stress components will be calculated using ANSYS [6]

and will be combined with piping loads in subsequent calculations.

Linearized stress components will be used for the fatigue usage calculation. For the nozzle blend radius location, the stresses used in the evaluation will be for the base metal only; that is, the cladding material will be unselected prior to stress extraction consistent with ASME Code rules and Reference [13].

The fatigue usage calculation will consider all six stress components, and will be performed using the rules of Subarticle NB-3200 of Section III of the ASME Code [1]. Calculated fatigue usage factors will be multiplied by the appropriate environmental fatigue multipliers computed for each location.

The results of this calculation are to be used in SIA calculations: No. 081038.305, Stress Analysis of Reactor Recirculation Outlet Nozzle and No. 081038.306, Fatigue Analysis of Recirculation Outlet Nozzle File No.: 0801038.304 Page 18 of 20 Revision: 1 F0306-01I

V StructuralIntegrityAssociates, Inc.

6.0 REFERENCES

1. American Society of Mechanical Engineers, Boiler and Pressure Vessel Code,Section III, Subsection NB, 1998 Edition, with Addenda through year 2000.
2. NUREG/CR-6583 (ANL-97/18), "Effects of LWR Coolant Environments on Fatigue Design Curves of Carbon and Low-Alloy Steels," March 1998.
3. J. P. Holman, "Heat Transfer," 5th Edition, McGraw Hill Inc.; 1981.
4. Structural Integrity Associates Calculation No. VY-16Q-305, Revision 0, "Recirculation Outlet Stress History Development for Nozzle Green Function."
5. CB&I, RPV Stress Report Sections S9 "Stress Analysis Recirculation Outlet Nozzle Vermont Yankee Reactor Vessel." and T9 "Thermal Analysis Recirculation Outlet Nozzle Vermont Yankee Reactor Vessel." CB&I Contract 9-620 1, SI File No. VY-16Q-204.
6. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.
7. Structural Integrity Associates Calculation No. VY-16Q-304, Revision 0, "Recirculation Outlet Nozzle Finite Element Model."
8. Entergy Design Input Record (DIR), Rev. 1, EC No. 1773, Rev. 0, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY-16Q-209.
9. GE Drawing No. 919D294, Revision 11, Sheet 7, "Reactor Vessel, Spec. Control," SI File No. VY-05Q-241.
10. American Society of Mechanical Engineers, Boiler and Pressure Vessel Code,Section II, Part D, 1998 Edition, with Addenda through year 2000.
11. Structural Integrity Associates Calculation No. VY-1 6Q-306, Revision 0, "Fatigue Analysis of Recirculation Outlet Nozzle."
12. N. P. Cheremisinoff, "Heat Transfer Pocket Handbook," Gulf Publishing Co., 1984.
13. NUREG/CR-6260 (INEL-95/0045), "Application of NUREG/CR-5999 Interim Fatigue Curves to Selected Nuclear Power Plant Components," March 1995.
14. Warren C. Young, "Roark's Formulas for Stress & Strain," Sixth Edition, McGraw- Hill Book Company, 1989.
15. NUREG/CR-5704, "Effects of LWR Coolant Environments on Fatigue Design Curves of Austenitic Stainless Steels," April, 1999.

FileNo.: 0801038.304 Page 19 of 20 Revision: 1 f0306-01i

V StructuralIntegrity Associates, Inc.

16. SI Calculation No. VY-19Q-301, Revision 0, "Design Inputs and Methodology for ASME Code Confirmatory Fatigue Usage Analysis of Reactor Feedwater Nozzle."
17. SI Calculation No. VY-19Q-302, Revision 0, "ASME Code Confirmatory Fatigue Evaluation of Reactor Feedwater Nozzle."
18. SI Calculation No. VY-19Q-303, Revision 0, "Feedwater Nozzle Environmental Fatigue Evaluation."
19. J. P. Holman, "Heat Transfer," 4th Edition, McGraw Hill Inc., 1976.
20. GE Stress Report 23A4316, Revision 0, "Stress Report-Reactor Vessel Recirculation Outlet Safe End," SI File No. VY-16-204.

File No.: 0801038.304 Page 20 of 20 Revision: 1 F0306-01

V StructuralIntegrityAssociates, Inc.

APPENDIX A:

ANSYS Input File: RONVY.INP FileNo.: 0801038.304 Page A-I of A-23 Revision: 1 F0306-O1F

StructuralIntegrity Associates, Inc.

ANSYS Input File: RONVY.INP finish

/clear, start

/prep7

/title, Recirc Outlet Nozzle Finite Element Model

/com, PLANE42, 2-D Solid et,1,PLANE42,,,1 !Axisymmetric

/com, ****************************

/com, Material Properties

/corn, ****************************

MPTEMP, , 70,200,300,400,500,600 tmp = 3600*12  ! hr-ft to sec-in

/COM, Material #1 Safe-End and Portion of Piping (SA-182 F316) (18Cr-8Ni)

MPDATA,EX ,1, , 28.3e6, 27.6e6, 27.0e6, 26.5e6, 25.8e6, 25.3e6 MPDATA,ALPX,I, , 8.5e-6, 8.9e-6, 9.2e-6, 9.5e-6, 9.7e-6, 9.8e-6 MPDATA, KXX,1I,, 8.6/tmp, 9.3/tmp, 9.8/tmp, 10.4/tmp, 10.9/tmp, 11.3/tmp MPDATA, C,1, , 0.116, 0.122, 0.125, 0.129, 0.131, 0.133 mp, nuxy, 1, 0. 3 mp, dens, 1,0.283

/COM, Material #2 (Nozzle Forging) SA-508 Class 2 (3/4Ni-I/2Mo-I/3Cr-V)

MPDATA,EX ,2, , 27.8e6, 27.1e6, 26.7e6, 26.1e6, 25.7e6, 25.2e6 MPDATA,ALPX,2, , 6.4e-6, 6.7e-6, 6.9e-6, 7.le-6, 7.3e-6, 7.4e-6 MPDATA, KXX,2, , 23.5/tmp, 23.6/tmp, 23.4/tmp, 23.1/tmp, 22.7/tmp, 22.2/tmp MPDATA, C,2, , 0.105, 0.114, 0.119, 0.125, 0.130, 0.135 mp, nuxy, 2, 0. 3 mp, dens, 2,0.283

/COM, Material #3 (Cladding) SA-240 Type 304 (18Cr-8Ni)

MPDATA,EX ,3, , 28.3e6, 27.6e6, 27.0e6, 26.5e6, 25.8e6, 25.3e6 MPDATA,ALPX,3, , 8.5e-6, 8.9e-6, 9.2e-6, 9.5e-6, 9.7e-6, 9. 8e-6 MPDATA, KXX,3, , 8.6/tmp, 9.3/tmp, 9.8/tmp, 10.4/tmp, 10.9/tmp, 11.3/tmp MPDATA, C,3, , 0.116, 0.122, 0.125, 0.129, 0.131, 0.133 mp, nuxy, 3, 0.3 File No.: 0801038.304 Page A-2 of A-23 Revision: 1 F0306-01I

StructuralIntegrity Associates, Inc.

mp, dens, 3,0.283

/COM, Material #4 (Vessel) SA-533, GR. B (Mn-1/2Mo-1/2Ni)-

MPDATA,EX 14, , 29.2e6, 28.5e6, 28.0e6, 27.4e6, 27.0e6, 26.4e6 MPDATA,ALPX,4, , 7.0e-6, 7.3e-6, 7.4e-6, 7.6e-6, 7.7e-6, 7.8e-6 MPDATA, KXX,4, , 23.5/tmp, 23.6/tmp, 23.4/tmp, 23.1/tmp, 22.7/tmp, 22.2/tmp MPDATA, C,4, , 0.105, 0.114, 0.119, 0.125, 0.130, 0.135 mp, nuxy, 4, 0. 3 mp,dens,4, 0.283

  • AFUN, DEG

/com, *** Geometric Parameters *

  • set,vira, (103+3/16) !Actual Vessel Inner Radius to base metal used for model
  • set,vir,2.0*vira !2.0 time of Vessel Inner Radius to base metal used for model
  • settvw,5+5/8-3/16 !Vessel Wall Thickness
  • set, ril, 25.75/2
  • setrol 28.375/2
  • set,L1,5
  • set, ro2,28.375/2
  • set, L2,4.25
  • set, ro3,28.875/2
  • set, ro4,48.75/2
  • set, L3, 1.5
  • set, L4, 5.25
  • set, L5,7+1/16
  • set, L6, 12+13/16
  • setL7,9+7/8
  • set,L8, 9+3/8
  • set,L9, 31+15/16
  • set, L0, L9-12-13/16-tvw
  • set, ra, 7
  • set, rb, 1
  • set, rc, 5.25
  • set, rd, 2.5
  • set, tv, 3/16
  • set,dimA,vir-(tv*2.0)+L9+11+Ll !Vessel Centerline to End of Safe End used for model
  • set,L21,1
  • set, L22,4.25
  • set,ri21, (25+15/16)/2

/com, Geometry File No.: 0801038.304 Page A-3 of A-23 Revision: 1 F0306-01,

VStructural IntegrityAssociates, Inc.

local, 13,0, , dimA, , .

csys, 13

/com, Begin at end of Safe-End - Carbon Section k, 9, ril, -1*(dimA) k, 2,f ril+tv, -l*(dimA) k, 3, rol, -!*(dimA) k, 4, ril, -l*(dimA-Ll) k, 5, ril+tv, -l*(dimA-Ll) k, 6, rol, -l*(dimA-Ll) k, 7, ril, -T*(dimA-Ly-L2) k, 8, ril+tv, -1*(dimA-L5-L2) k, 9f ro2, -r*(dimA-Li-L2) k, 10, ril, -I*(dimA-LI-L2-,L3) k,22, ril+tv, -I*(dimA-LI-L2-L3) k, 12, 1o3, -r*(dimA-Lb-L2-L3) k, 13, ril, -1*(dimA.Ll-L2-L3-L4) k, 24, ril+tv, -I*(dimA-LI-L2-L3-L4) k, 15, ro3, -1*(dimA-Lt-L2-L3-L4) k, 16, ril, -1*(dimA-Lt-L2-L3-L4-L5) k, 17, ril+tv, - t*(dimA-Ln-L2-L3-L4-L5) k, 18, ro3, -1*(dirtA-LP-L2-L3-L4-L5) k,19, ro4, -0*(dimA-LI-L2-L3-L4-L5-L7)!Temporary Point 1, 19, 18 1,18,15 fillc, 29,i3,2,ira k,22, ro4+(LS+6)*tan(15), -I*(dimA-LI-L2-L3-L4-L5-L7-(L8+6) 1, 19, 22 LFILLT, 1i, 4, rb k, 25, ril, -I*(dimA-LI-L2-L3-L4-L6) k, 26, ril+tv, -I*(dimA-Ll-L2-L3-L4-L6) k, 27, ril+(Ll0+tvw+ltv+4)*tan(15), -l*(vir-tv-4) k, 28, ril+tv+(L10+tvw+t~v+4)*tan(15), -l*(vir-tv-4) k,29, (vir+tvw+tv) tsin (45) . -l* (vir+tvw+tv) *cos (45) k,30, 0, -l*(vir+tvw+tv) !Temporary Point k,31., 0, 0 ! Temporary Point larc, 29, 30, 31, vir+tvw+tv k,32, (.vir+tv)*sin(45), -1*(vir+tv)*cos(45)

File No.: 0801038.304 Page A-4 of A-23 Revision: I F0306-01I

StructuralIntegrity Associates, Inc.

k,33, 0, -1*(vir+tv) Temporary Point larc, 32, 33, 31,vir+tv k,34, vir*sin(45), -1*vir*cos(45) k,35, 0, -l*vir Temporary Point larc, 34,35,31,vir LSTR, 4, 5 LSTR, 5, 6 LSTR, 6, 9 LSTR, 9, 12 LSTR, 12, 15 LSTR, 5, 8 LSTR, 4, 7 LSTR, 7, 10 LSTR, 8, 11 LSTR, 11, 14 LSTR, i0, 13 LSTR, 13, 16 LSTR, 14, 17 LSTR, 16, 25 LSTR, 17, 26 LSTR, 26, 28 LSTR, 25, 27 LSTR, 4, 1 LSTR, 1, 2 LSTR, 2, 3 LSTR, 3, 6 LSTR, 5, 2 LSTR, 7, 8 LSTR, 8, 9 LSTR, 12, 11 LSTR, 11, 10 LSTR, 13, 14 LSTR, 14, 15 FLST, 2,2,4, ORDE, 2 FITEM, 2,4 FITEM, 2, 6 LPTN, P51X FLST, 2,2, 4, ORDE, 2 FITEM, 2,8 FITEM, 2,25 LPTN, P51X FLST, 2,2,4,ORDE, 2 FileNo.: 0801038.304 Page A-5 of A-23 Revision: 1 F0306-01

V StructuralIntegrityAssociates, Inc.

FITEM, 2, 7 FITEM, 2,24 LPTN, P51X FLST, 2, 6, 4, ORDE, 6 FITEM, 2, 6 FITEM, 2,25 FITEM, 2,37 FITEM, 2,40 FITEM, 2,42 FITEM, 2,44 LDELE,P51X, , .1 LFILLT,4,41,rd, ,

1*

LFILLT, 43, 8, rd, .

LFILLT, 39, 38, rc, FLST, 2,3, 4,ORDE, 3 FITEM, 2,1 FITEM, 2,3 FITEM, 2,5 LCOMB,P51X, ,0 LSTR, 16, 17 LSTR, 17, 21 LSTR, 25, 26 LSTR, 26, 24 LSTR, 22, 30 LSTR, 30, 35 LSTR, 27, 28 LSTR, 28, 33 LSTR, 29, 32 LSTR, 32, 34 k,39, 0, -1*(vir+tvw+tv)

!Create Areas FLST, 2,4,4 FITEM, 2,27 FITEM, 2,30 FITEM, 2,26 FITEM, 2, 9 AL, P51X, FLST, 2,4,4 FITEM, 2,28 File No.: 0801038.304 Page A-6 of A-23 Revision: 1 F0306-011

V StructuralIntegrityAssociates, Inc.

FITEM, 2,29 FITEM, 2, 10 FITEM, 2,30 AL, P51X FLST, 2,4,4 FITEM, 2, 11 FITEM, 2,32 FITEM, 2, 10 FITEM, 2, 14 AL, P51X FLST, 2,4,4 FITEM, 2, 15 FITEM, 2, 14 FITEM, 2, 9 FITEM, 2, 31 AL, P51X FLST, 2,4,4 FITEM,2,32 FITEM, 2,33 FITEM, 2, 12 FITEM, 2, 17 AL, P51X FLST, 2,4,4 FITEM, 2, 16 FITEM, 2, 17 FITEM, 2,31 FITEM, 2,34 AL, P51X FLST, 2,4,4 FITEM, 2,36 FITEM, 2, 13 FITEM, 2,33 FITEM, 2, 18 AL, P51X FLST, 2, 4, 4 FITEM, 2, 19 FITEM, 2, 18 FITEM, 2,35 FITEM, 2,34 AL, P51X FLST, 2,4,4 FITEM, 2,2 FITEM, 2, 5 FITEM, 2,36 FITEM, 2,21 AL, P51X FLST, 2,4,4 File No.: 0801038.304 Page A-7 of A-23 Revision: 1 F0306-01

StructuralIntegrity Associates, Inc.

FITEM, 2,20 FITEM, 2, 21 FITEM, 2, 3 FITEM, 2,35 AL, P51X FLST, 2,4,4 FITEM, 2, 1 FITEM, 2,37 FITEM, 2,23 FITEM, 2,5 AL, P51X FLST, 2,4,4 FITEM, 2,22 FITEM, 2,23 FITEM, 2,25 FITEM, 2,3 AL, P51X FLST, 2,4,4 FITEM, 2,38 FITEM, 2,42 FITEM, 2,37 FITEM, 2, 8 AL, P51X FLST, 2,4,4 FITEM, 2, 4 FITEM, 2,8 FITEM, 2,25 FITEM, 2,40 AL, PSIX FLST, 2,4,,4 FITEM, 2,24 FITEM, 2,45 FITEM, 2,7 FITEM, 2,42 AL, P51X FLST, 2,4,4 FITEM, 2, 6 FITEM, 2, 7 FITEM, 2,44 FITEM, 2,40 AL, P51X FLST, 2,4,4 FITEM, 2, 41 FITEM, 2,43 FITEM, 2, 47 FITEM, 2,44 AL, P51X File No.: 0801038.304 Page A-8 of A-23 Revision: 1 F0306-01.

VStructural Integrity Associates, Inc.

FLST, 2, 4,4 FITEM, 2,39 FITEM, 2, 46 FITEM, 2, 45 FITEM, 2,43 AL, P51X define materials FLST, 5,8,5, ORDE, 2 FITEM, 5,1 FITEM, 5, -8 CM, Y,AREA ASEL, , , ,P51X CM, Y1,AREA CMSEL,S,_Y 1*

CMSEL,S, _YI AATT, 1, , 1, 0, CMSEL,S, Y CMDELE, Y CMDELE, Y1 1*

FLST, 5,5,5, ORDE, 5 FITEM, 5,9 FITEM, 5,11 FITEM, 5,13 FITEM, 5,15 FITEM, 5,18 CM, _Y,AREA ASEL, , , ,P51X CM, _Y1,AREA CMSEL,S, Y I*

CMSEL,S, Y1 AATT, 2, , 1, 0, CMSEL,S, Y CMDELE, _Y CMDELE, Y1 FLST, 5,5,5, ORDE, 5 FITEM, 5,10 FITEM, 5,12 FITEM, 5,14 FITEM, 5,16 FITEM, 5, -17 CM, _Y,AREA ASEL, , , ,P51X File No.: 0801038.304 Page A-9 of A-23 Revision: I F0306-01:

V StructuralIntegrityAssociates, Inc.

CM, _Y, AREA CMSEL, S, _Y CMSEL,S,_YI AATT, 3, , 1, 0, CMSEL, S, _Y CMDELE, Y CMDELE, Y1 I*

!/com, Map mesh areas FLST, 5,10,4,ORDE, 10 FITEM, 5,5 FITEM, 5, 10 FITEM, 5,28 FITEM, 5,32 FITEM, 5,-33 FITEM, 5,36 FITEM, 5,-37 FITEM, 5,42 FITEM, 5,45 FITEM, 5, -46 CM, _Y,LINE LSEL, , , ,P51X CM, Y1,LINE CMSEL,, _Y LESIZE, Y1, , ,15, , , ,i 1*

FLST, 5,10,4, ORDE, 10 FITEM, 5,3 FITEM, 5,9 FITEM, 5,25 FITEM, 5,27 FITEM, 5,31 FITEM, 5,34 FITEM, 5,-35 FITEM, 5,40 FITEM, 5, 44 FITEM, 5,47 CM, Y,LINE LSEL, , , ,P51X CM, YI,LINE CMSEL,, _Y I*

LESIZE, .Y1,

, ,2, , ,

1*

File No.: 0801038.304 Page A-10 of A-23 Revision: I F0306-011

VFLST, Structural IntegrityAssociates, Inc.

5,3,4, ORDE, 3 FITEM., 5, 39 FITEM, 5, 41 FITEM, 5,43 CM, _Y, LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,, _Y LESIZE, YI, ,80, , , , l 1*

FLST,5,3,4,ORDE,3 FITEM, 5,6 FITEM, 5, -7 FITEM,5,24 CM, _Y,LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,, _Y LESIZE, Y1, , ,20, , , ,

1*

FLST, 5,3,4, ORDE, 3 FITEM, 5,4 FITEM, 5,8 FITEM, 5,38 CM, _Y,LINE LSEL, , , ,P51X CM, Y1,LINE CMSEL,,__Y 1*

LESIZE,_Y1, , ,40, , , , fl FLST, 5,3,4,ORDE, 3 FITEM, 5,1 FITEM, 5,22 FITEM, 5, -23 CM, _Y,LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,, _Y LESIZE, Y1, , ,30, , , , .

FLST, 5, 6,4,ORDE, 6.

FITEM, 5,2 FITEM, 5,20 FileNo.: 0801038.304 Page A-I I of A-23 Revision: 1 F0306-011

0 StructuralIntegrity Associates, Inc.

FITEM, 5, -21 FITEM, 5,26 FITEM, 5,29 FITEM, 5, -30 CM, _Y, LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,, _Y 1*

LESIZE, Y1, , ,40, , , , ,I 1*

FLST, 5, 9, 4, ORDE, 2 FITEM, 5, 11 FITEM, 5, -19 CM, Y,LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,,__Y 1*

LESIZE, Y1, , ,20, , , , ,i 1*

Meshing FLST, 5, 18,5, ORDE, 2 FITEM, 5,1 FITEM, 5, -18 SCM, _Y,AREA ASEL, , , ,P51X CM, _Y1,AREA CHKMSH, 'AREA' CMSEL,S,_Y 1*

MSHKEY, 1 AMESH, Y1 MSHKEY, 0 i*

CMDELE, Y CMDELE, _Y1 CMDELE, Y2 1*

!Modify the safe end ID FLST, 2, 6, 5, ORDE, 2 FITEM, 2,1 FITEM, 2, -6 ACLEAR, P51X FLST, 2, 6, 5, ORDE, 2 File No.: 0801038.304 Page A-12 of A-23 Revision: 1 F0306-01

V StructuralIntegrity Associates, Inc.

FITEM, 2, 1 FITEM, 2, -6 ADELE, P51X FLST,2,9, 4,ORDE,7 FITEM, 2,9 FITEM, 2,14 FITEM, 2, -17 FITEM, 2,26 FITEM, 2, -27 FITEM, 2,30 FITEM, 2, -31 LDELE,P51X, , .1 FLST, 2,3,4,ORDE, 3 FITEM, 2,10 FITEM, 2,28 FITEM, 2,32 LDELE,P51X, , .1 FLST, 3,2,3, ORDE, 2 FITEM, 3,3 FITEM, 3,6 KGEN,2,P51X, , ,-ro2+ri2l, , , ,0 FLST, 3,1, 3,ORDE, 1 FITEM, 3,2 KGEN,2,P51X, , , ,L22, , ,0 FLST, 3, 3,3, ORDE, 3 FITEM, 3,1 FITEM, 3, -2 FITEM, 3, 4 KGEN,2,P51X, , ,tv, , , ,0 FLST, 3,2, 3, ORDE, 2 FITEM, 3, 10 FITEM, 3,-li KGEN,2,P51X, , , ,-(L3-L21), , ,0 FLST, 3, 1, 3, ORDE, 1 FITEM, 3,23 KGEN,2,P51X, , ,5, , , ,0 LSTR, 23, 40 FLST,2,2,4,ORDE,2 FITEM, 2,9 FITEM, 2,12 LPTN, P51X LDELE, 16, , ,i FLST, 2,4,3 FITEM, 2, 11 FITEM, 2,23 FITEM, 2,41 FileNo.: 0801038.304 Page A-13 of A-23 Revision: I F0306-0t1

VStructural IntegrityAssociates, Inc.

FITEM, 2,12 A, P51X FLST, 2,4,3 FITEM, 2,23 FITEM, 2, 8 FITEM, 2, 9 FITEM, 2,41 A, P51X FLST,2, 4,3 FITEM, 2, 8 FITEM, 2, 7 FITEM, 2, 6 FITEM, 2, 9 A, P51X FLST, 2, 4,3 FITEM, 2,7 FITEM, 2, 5 FITEM, 2,3 FITEM, 2, 6 A, P51X FLST, 2,4,3 FITEM, 2, 10 FITEM, 2,20 FITEM, 2,23 FITEM, 2, 11 A, P51X FLST, 2,4,3 FITEM, 2,20 FITEM, 2, 4 FITEM, 2,8 FITEM, 2,23 A, P51X FLST, 2,4,3 FITEM, 2, 4 FITEM, 2,2 FITEM, 2,7 FITEM, 2, 8 A, P51X FLST, 2, 4,3 FITEM, 2,2 FITEM, 2, 1 FITEM, 2, 5 FITEM, 2,7 A, P51X FLST,5,8,5,ORDE, 4 FITEM, 5,1 FITEM, 5, -6 File No.: 0801038.304 Page A-14 of A-23 Revision: 1 F0306-OL

StructuralIntegrity Associates, Inc.

FITEM, 5, 19 FITEM, 5,-20 CM, _Y, AREA ASEL, , , ,P51X CM, _Y1,AREA CMSEL,S, Y 1*

CMSEL,S, Y1 AATT, i, , 1, 0, CMSEL,S, Y CMDELE, _Y CMDELE, Y1 1*

FLST, 5, 4,4,ORDE, 4 FITEM, 5, 15 FITEM, 5, -16 FITEM, 5,26 FITEM, 5, 28 CM, _Y,LINE LSEL, , , ,P51X CM, Y1,LINE CMSEL,,_Y i*

LESIZE, YI, , ,15, , , , ,i 1*

FLST, 5,4,4,ORDE, 4 FITEM, 5,31 FITEM, 5,48 FITEM, 5,50 FITEM, 5,52 CM, Y,LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,, _Y 1*

LESIZE, Y1, , ,2, , , , 1 FLST, 5,6, 4,ORDE, 6 FITEM, 5,9 FITEM, 5,-l0 FITEM, 5, 12 FITEM, 5, 14 FITEM, 5, 30 FITEM, 5,32 CM, _Y,LINE LSEL, , , ,P51X CM, Y1,LINE FileNo.: 0801038.304 Page A-15 of A-23 Revision: I F0306-01!

V StructuralIntegrity Associates, Inc.

CMSEL,, _Y 1*

LESIZE, Y1, , , 6, , , , ,i 1*

FLST, 5,3,4, ORDE, 3 FITEM, 5, 11 FITEM, 5, 17 FITEM, 5,49 CM, _Y, LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,, _Y LESIZE, Y1, , ,12, , , , ,i 1*

FLST, 5,3, 4,ORDE, 3 FITEM, 5,27 FITEM, 5,29 FITEM, 5,51 CM, _Y,LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,,__Y LESIZE, Y1, , ,25, , , , ,i 1*

FLST, 5, 8, 5, ORDE, 4 FITEM, 5,1 FITEM, 5, -6 FITEM, 5,19 FITEM, 5,-20 CM, _Y,AREA ASEL, , , ,P51X CM, _Y1,AREA CHKMSH, 'AREA' CMSEL,S, _Y 1*

MSHKEY, 1 AMESH, Y1 MSHKEY, 0 i*

CMDELE, Y CMDELE, _Y1 CMDELE, Y2 1*

FLST, 2,2,5, ORDE, 2 FileNo.: 0801038.304 Page A-16 of A-23 Revision: 1 F0306-01

V StructuralIntegrityAssociates, Inc.

FITEM, 2,17 FITEM, 2, -18 ACLEAR,P51X csys, 0 k, 51,62/2,0,0 k, 52,62/2,60,0 LSTR, 51, 52 FLST, 2,2,5, ORDE, 2 FITEM, 2,17 FITEM, 2, -18 ADELE, P5IX iplo FLST, 2,4,4, ORDE, 4 FITEM, 2,39 FITEM, 2,41 FITEM, 2,43 FITEM, 2,53 LPTN, PSIX FLST, 2,2,4, ORDE, 2 FITEM, 2,60 FITEM, 2, -61 LDELE,P51X, , .1 FLST, 2,4,4 FITEM, 2,54 FITEM, 2, 62 FITEM, 2,55 FITEM, 2,44 AL, P51X FLST, 2,4,4 FITEM, 2,55 FITEM, 2,63 FITEM, 2,58 FITEM, 2,45 AL, P51X FLST,2,4,4 FITEM, 2,63 FITEM, 2,56 FITEM, 2,57 FITEM, 2,46 AL, P51X FLST, 2,4,4 FITEM, 2,47 FITEM, 2,59 FITEM, 2,57 FITEM, 2,62 AL, PSIX File No.: 0801038.304 Page A-17 of A-23 Revision: 1 F0306-01

StructuralIntegrity Associates, Inc.

CM, _Y, AREA ASEL, , , , 18 CM, _Y1,AREA CMSEL, S, _Y 1*

CMSEL,S, Y1 AATT, 2, , 1, 0, CMSEL, S, _Y CMDELE, Y CMDELE,, Y1 FLST, 5,2,5, ORDE, 2 FITEM, 5, 17 FITEM, 5,22 CM, _Y, AREA ASEL, , , ,P51X CM, _Y1,AREA CMSEL,S, _Y 1*

CMSEL,S, Y1 AATT, 3, r 1, 0, CMSEL, S, _Y CMDELE, _Y CMDELE, __Y CM, Y, AREA ASEL, . . . 21 CM, _Y1,AREA CMSEL, S, Y CMSEL,S, Y1 AATT, 4, j 1, 0, CMSEL, S, _Y CMDELE, Y CMDELE, _YI 1*

FLST, 5,3,4,ORDE, 3 FITEM, 5,54 FITEM, 5, -55 FITEM, 5,58 CM, _Y,LINE LSEL, , , ,P51X CM, Y1,LINE CMSEL,,__Y LESIZE, Y1, , ,8, , , , ,i File No.: 0801038.304 Page A- 18 of A-23 Revision: 1 F0306-011

StructuralIntegrity Associates, Inc.

FLST, 5,3,4,ORDE, 3 FITEM, 5, 56 FITEM, 5,-57 FITEM, 5,59 CM, _Y,LINE LSEL, , , ,P51X CM, _Y1,LINE CMSEL,, _Y 1*

LESIZE, YI, , ,40, , , , ,i FLST, 5,2,5, ORDE, 2 FITEM, 5,17 FITEM, 5,-18 CM, Y,AREA ASEL, , , ,P51X CM, _Y1,AREA CHKMSH, 'AREA' CMSEL,S, Y MSHKEY, 1 AMESH, Y1 MSHKEY, 0 L*

CMDELE, Y CMDELE, _Y1 CMDELE, Y2 I*

FLST, 5,2,5, ORDE, 2 FITEM, 5,21 FITEM, 5, -22 CM, Y,AREA ASEL, , , ,P51X CM, Y1,AREA CHKMSH, 'AREA' CMSEL,S, Y i*

MSHKEY, 1 AMESH, Y1 MSHKEY, 0 CMDELE, Y CMDELE, Y1 CMDELE, Y2 1*

File No.: 0801038.304 Page A-19 of A-23 Revision: 1 F0306-01

VStructuralIntegrityAssociates, Inc.

!Simulating Butter FLST, 2,2,5,ORDE, 2 FITEM,2,9 FITEM, 2, -10 ACLEAR, P51X FLST, 2,2,5, ORDE, 2 FITEM, 2,9 FITEM, 2, -10 ADELE, P51X KGEN,2,15, , , ,11/16, , ,0 KGEN,2,44, , , ,-0.25, , ,0 KGEN,2,14, , , ,11/16-1.375*tan(7.5) , 0 KGEN,2,46, , , ,-0.25, , ,0 FLST, 2, 3, 4,ORDE, 3 FITEM, 2,2 FITEM, 2,20 FITEM, 2, -21 LDELE, P51X LSTR, 21, 44 LSTR, 44, 45 LSTR, 45, 15 LSTR, 17, 46 LSTR, 46, 47 LSTR, 47, 14 LSTR, 46, 44 LSTR, 45, 47 LSTR, 13, 16 FLST, 3,2, 3,ORDE, 2 FITEM, 3,46 FITEM, 3,-47 KGEN,2,P51X, , ,-0.25, , ,0 LSTR, 48, 46 LSTR, 49, 47 FLST, 2,3,4,ORDE, 3 FITEM, 2,61 FITEM, 2,64 FITEM, 2, -65 LPTN, P51X FLST, 2,2,4,ORDE, 2 FITEM, 2,70 FITEM, 2, -71 LDELE,P51X, , .1 FLST, 2,4,4 FITEM, 2, 67 FITEM, 2,39 File No.: 0801038.304 Page A-20 of A-23 Revision: 1 F0306-01

StructuralIntegrity Associates, Inc.

FITEM, 2,68 FITEM, 2, 3 AL, P51X FLST, 2,4,4 FITEM, 2,39 FITEM, 2, 5 FITEM, 2, 2 FITEM, 2,53 AL, P51X FLST, 2,4,4 FITEM, 2,20 FITEM, 2, 60 FITEM, 2,53 FITEM, 2, 41 AL, P51X FLST, 2,4,4 FITEM, 2,72 FITEM, 2,68 FITEM, 2,69 FITEM, 2,41 AL, P51X FLST, 2,4,4 FITEM, 2,21 FITEM, 2,60 FITEM, 2,36 FITEM, 2,43 AL, P51X FLST, 2,4,4 FITEM, 2,66 FITEM, 2,69 FITEM, 2,35 FITEM, 2,43 AL, P51X CM, _Y, AREA ASEL, , , , 10 CM, Y1,AREA CMSEL, S, _Y 1*

CMSEL,S, Y1 AATT, 2, , 1, 0, CMSEL, S, _Y CMDELE, Y CMDELE, Y1 1*

FLST, 5,3,5, ORDE, 3 FITEM, 5, 9 FileNo.: 0801038.304 Page A-21 of A-23 Revision: 1 F0306-011

StructuralIntegrity Associates, Inc.

FITEM, 5,23 FITEM, 5,-24 CM, Y, AREA ASEL, , , ,P51X CM, Y1,AREA CMSEL,S, _Y 1*

CMSEL,S, __Y AATT, 3, , 1, 0, CMSEL,S, Y CMDELE, Y CMDELE, _Y1 FLST, 5,2, 5, ORDE, 2 FITEM, 5,25 FITEM, 5, -26 CM, Y,AREA ASEL, , , ,P51X CM, _Y1,AREA CMSEL,S, Y 1,

CMSEL,S, _YI AATT, i, , i, 0, CMSEL,S, _Y CMDELE, Y CMDELE, Y1 1*

FLST, 5,3,4,ORDE, 3 FITEM, 5,2 FITEM, 5,39 FITEM, 5,67 CM, Y,LINE LSEL, , , ,P51X CM, Y1,LINE CMSEL,, _Y i*

LESIZE, YI, , ,10, , , ,

FLST, 5, 6, 4,ORDE, 6 FITEM, 5,20 FITEM, 5,-21 FITEM, 5,41 FITEM, 5,43 FITEM, 5,66 FITEM, 5,72 CM, Y,LINE LSEL, , , ,P51X File No.: 0801038.304 Page A-22 of A-23 Revision: 1 F0306-O.

StructuralIntegrity Associates, Inc.

CM, _Y1, LINE CMSEL, , _Y LESIZE, Y1, , ,2, , , , ,i 1*

FLST, 5, 2, 5, ORDE, 2 FITEM,5, 9 FITEM, 5,-i0 CM, _Y,AREA ASEL, , , ,P51X CM, Y1,AREA CHKMSH, 'AREA' CMSEL,S, _Y 1*

MSHKEY,1 AMESH, _Y1 MSHKEY, 0 CMDELE,1Y CMDELE, Y1 CMDELE, _Y2 I*

FLST, 5,4,5, ORDE, 2 FITEM, 5,23 FITEM, 5, -26 CM, _Y,AREA ASEL, , , ,P51X CM, _Y1,AREA CHKMSH, 'AREA' CMSEL,S, _Y MSHKEY, 1 AMESH, Y1 MSHKEY, 0 1*

CMDELE, Y CMDELE, _YI CMDELE, Y2 1*

save finish File No.: 0801038.304 Page A-23 of A-23 Revision: 1 F0306-01,

StructuralIntegrityAssociates, Inc. File No.: 0801038.305 CALCULATION PACKAGE Project No.: 0801038 Quality Program Z Nuclear [] Commercial PROJECT NAME:

VY Confirmatory Analysis for the CS and RO Nozzles CONTRACT NO.:

10163217 Amendment 5 CLIENT: PLANT:

Entergy Nuclear Operations, Inc Vermont Yankee Nuclear Power Station CALCULATION TITLE:

Stress Analysis of Reactor Recirculation Outlet Nozzle Project Manager Preparer(s) &

Document Affected Revision Description Approval Checker(s)

Revision Pages Signature & Date Signatures & Date 01 - 16 Initial issue. Preparer:

Gary L. Stevens Computer Files 01/07/09 Tyler Novotny 01/07/09 Checker:

R. D. Dixon 01/07/09 1 1-9, 11, 15 Revised per summary Preparer:

contained in Section 1.1.

Changes are marked with revision bars" in right- 0 9 TlrDNnt hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker:

Tim D. Gilman 03/09/09 Page 1 of 16 F0306-OIRO

VStructural IntegrityAssociates, Inc.

Table of Contents 1.0 OB JEC TIV E ................................................................................................................................. 3 1.1 Changes Made in Revision 1 of this Calculation ........................................................... 3 2.0 METHODOLOGY ............................................................................................................... 3 3.0 ASSUMPTIONS / DESIGN INPUTS ..................................................................................... 4 4.0 CA LCU LA TION S ........................................................................................................................ 4 4.1 Finite Element Unit Pressure Stress Analysis ................................................................. 4 4.2 Thermal Transient Stress Analysis .................................................................................. 4 4.3 Determining Critical Stress Paths .................................................................................. 5 4.4 Stress C alculation ........................................................................................................... . .6 4.5 Piping L oads ............................................................................................................... 7 5.0 RESULTS OF ANALYSIS ..................................................................................................... 8 6.0 REFEREN C E S ............................................................................................................................. 9 List of Tables Table 1: Pressure Stress Intensity Results (1,000 psi) ...................................................................... .7 Table 2: Stresses Under Unit Pressure Load, psi .................................. 10 Table 3: Example Thermal Stress Result Output, psi ......................................................................... 11 List of Figures Figure 1. RO Nozzle Internal Pressure Distribution ...................................................................... 12 Figure 2. RO Nozzle Pressure Cap Load & Boundary Condition ................................................. 13 Figure 3. RO Nozzle Vessel Wall Boundary Condition ............................................................... 14 Figure 4. Safe End Critical Thermal Stress Intensity Location .......................................................... 15 Figure 5. Nozzle Blend Radius Limiting Pressure Stress Intensity Location ................................. 16 Figure 6. Limiting Stress Paths ..................................................................................................... 16 FileNo.: 0801038.305 Page 2 of 16 Revision: 1 F0306-OIRO

1.0 OBJECTIVE The objective of this calculation package is to obtain stress distributions for the reactor pressure vessel (RPV) recirculation outlet (RO) nozzle at the Vermont Yankee Nuclear Power Station.

ANSYS [1] thermal transient and pressure stress analyses are performed, along with calculation of stresses due to attached piping loads. The stress results will be used for a subsequent ASME Code,Section III NB-3200 [2] fatigue usage calculation.

1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision 1 of this calculation:

a. Transient 9 described in Section 4.3 was changed to more precisely match the Green's Function analysis. This also required modification of the input files VY_RONTRAN9-T.INP and VY RON TRAN9-S.INP.
b. The input files VY_RON_TRAN2-T.INP and VY_RONTRAN2-S.INP were modified to include a finer time step around 601 seconds.
c. A Kt value of 1.53 that was conservatively applied to piping loads at blend radius was changed to Kt = 1.0 to match the Green's Function analysis.
d. Table 3 was revised because the input file VYRONTRAN4-T.INP was updated to correct a conservative misapplication of a temperature ramp rate.
e. Figure 4 was revised because Transient 9, which produced Figure 4, was modified.
f. All remaining changes marked throughout this calculation are editorial changes made to the text of the calculation package.

2.0 METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package

[3]. A previously developed finite element model (FEM) [3] of the RO nozzle is used to perform thermal and pressure stress analyses using ANSYS [1]. A thermal transient analysis is performed for each defined transient. Concurrent with the thermal transients are pressure and piping interface loads. For these loads, unit load analyses (based on finite element analysis for pressure and manual calculations for attached piping loads) are performed. All six components of the stress tensor are determined in the stress calculations.

The fatigue usage calculation and environmental fatigue usage analysis will be performed in a separate calculation package. That subsequent calculation will utilize the thermal and pressure stresses determined in this calculation, along with stresses due to attached piping loads provided in Tables 4 and 5 of Reference [3]. The stresses due to pressure and the attached piping loads will be scaled based on the temperature and pressure magnitudes during each individual transient, and the location being analyzed. The appropriate nozzle blend radius effects factor will also be applied to the total stresses for the nozzle blend radius location.

FileNo.: 0801038.305 Page 3 of 16 Revision: 1 F0306-O1RO

3.0 ASSUMPTIONS / DESIGN INPUTS Assumptions and design inputs were previously established in Section 3.0 of the Reference [3]

calculation. Assumption 3.1.3 of Reference [3] was verified in this calculation package by plotting the stress components of each transient in ANSYS. If the stress components plot did not contain a step change at the end of the transient, the steady state portion, the steady state time step assumed was determined to be adequate.

4.0 CALCULATIONS 4.1 Finite Element Unit Pressure Stress Analysis A uniform pressure of 1,000 psi was applied to the FEM along the inside surface of the RO nozzle and the RPV wall (Figure 1). A pressure load of 1,000 psi was used because it is easily scaled up or down to account for different pressures that occur during transients. In addition, a membrane stress "cap load" was applied to the modeled end of the piping attached to the RO nozzle safe end. This membrane stress was calculated as follows:

PD.

PDi 2 P

Pcap = 2 2 where:

P = Pressure = 1,000 psi unit load Di= Inner Diameter at end of model = 25.9375 in Do = Outer Diameter at end of model = 28.375 in Therefore, the membrane stress is 5,082 psi. The calculated value is given a negative sign in order for it to exert tension on the piping end of the model. The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, input file RONVY.INP]. The ANSYS input file VY RON P.INP contains the pressure loading. Figure 1 shows the applied 1,000 psi internal pressure distribution. At the vessel wall, a symmetric boundary condition is applied. At the piping end of the model, axial displacement is coupled to simulate the effect of the attached piping that is not modeled. Figure 2 and Figure 3 show the boundary conditions.

4.2 Thermal Transient Stress Analysis The FEM geometry input file is taken from the calculation that specifies the design and methodology inputs [3, file RONVY.INP], and is used as input to the files in which the thermal transient and pressure stress analyses are performed.

For the thermal transient ANSYS analyses, previously defined thermal transients [3, Table 1] are evaluated, applying heat transfer coefficients [3, Table 2], as appropriate, based on the flow rates for each individual transient.

Each thermal transient is evaluated in ANSYS to determine the resulting temperature distributions.

The thermal results are used as input for the stress analysis for each transient. The boundary FileNo.: 0801038.305 Page 4 of 16 Revision: 1 F0306-O1RO

StructuralIntegrityAssociates, Inc.

conditions used for the pressure load case were also applied to the thermal stress cases. Figure 2 and Figure 3 show the application of these boundary conditions.

All ANSYS input files for the thermal analyses, as listed below, are saved in the project computer files:

RON VYINP: Geometry and material properties VYRON TRAN]-T.INP, VYRONTRAN]-S.INP: Transient 1, thermal and stress analyses VYRONTRAN2-TINP, VY_RONTRAN2-S.INP: Transient 2, thermal and stress analyses VY_RON TRAN3-T.INP, VYRONTRAN3-S.INP: Transient 3, thermal and stress analyses VYRONTRAN4-T.INP, VY RONTRAN4-S.INP: Transient 4, thermal and stress analyses VYRONTRAN5-T.INP, VYRONTRAN5-S.INP: Transient 5, thermal and stress analyses VY RON TRAN6-T.INP, VY RON TRAN6-S.INP: Transient 6, thermal and stress analyses VYRONTRAN7-T.INP, VYRONTRAN7-S.INP: Transient 7, thermal and stress analyses VYRONTRAN8-T.INP, VY RON TRAN8-S.INP: Transient 8, thermal and stress analyses VYRONTRAN9-TINP, VYRONTRAN9-S.INP: Transient 9, thermal and stress analyses VYRONTRANIO-T.INP, VY RON TRANIO-S.INP: Transient 10, thermal and stress analyses VYRON_TRAN]]-T.INP, VYRONTRAN1-US.INP: Transient 11, thermal and stress analyses VYRON_TRAN12-T.INP, VYRONTRAN12-S.INP: Transient 12, thermal and stress analyses 4.3 Determining Critical Stress Paths The thermal transient that is to be used in determining the critical stress path at the safe end was determined by the most severe temperature difference over the shortest amount of time. This transient, Transient 9, is intended to represent the worst case thermal transient. This occurs during the Improper Startup cycle per Reference [3, Table 1]. The thermal transient conditions are:

  • 12% flow rate heat transfer coefficients.

Thermal shock from 526°F to 130'F along the inside surface of the nozzle safe end and piping and a blend radius and lower vessel thermal shock from 526 0F to 2680 F.

  • Constant temperatures from previous step for 26 seconds
  • Thermal shock from 130'F to 526°F along the inside surface of the nozzle safe end and piping and a blend radius and lower vessel thermal shock from 268'F to 526°F.
  • Steady state temperature conditions following thermal shocks.
  • Constant temperature of 120'F on the outside surface of the model.

The ANSYS input files for the analysis, as listed below, are saved in the project computer, files:

RONVYINP. Geometry and material properties VYRONTR4N9-T.INP, VYRONTRAN9-S.INP: Thermal and stress analysis for the worst case transient for the safe end An interactive review of the worst case thenral stress results (which are controlling for the safe end) showed the critical location in the model to be at Node 6395. The location of Node 6395 is shown in FileNo.: 0801038.305 Page 5 of 16 Revision: 1 F0306-O1RO

Figure 4. This location was selected since it possessed the highest stress intensity during the worst case thermal transient. This is the same location evaluated in Reference [4].

A critical stress location in the nozzle blend radius will also be analyzed. This location is chosen based upon the highest pressure stress (which is controlling in the nozzle blend radius) in the base metal. An interactive review of the pressure stress intensity results showed the critical location in the nozzle blend radius to be at Node 3829 (Figure 5). This is the same location evaluated in Reference [4].

Figure 6 shows the two critical stress paths that will be used to extract the linearized stresses at the safe end and nozzle blend radius.

4.4 Stress Calculation Linearized stresses from Node 6395 (safe end inside surface) and Node 3829 (nozzle blend radius inside surface of base metal) are used for the fatigue usage analysis, as shown in Figure 6. For the nozzle blend radius location, the stresses used are for the base metal only; since the cladding is of the integrally bonded type and is less than 10% of the total thickness of the section the material is unselected prior to stress extraction, per NB-3 122.3 [2].

The pressure stress intensities for the safe end and blend radius paths were extracted using the ANSYS file VY/RONP.INP. This produced one file, ROPRESSURE.lin, that contains results of the critical stress paths.

Table 1 shows the final pressure stress intensity results for the safe end and blend radius. The results at the blend radius are slightly different from those reported in Table 2 of Reference [4] as a result of the revised material properties (i.e., temperature dependent material properties were used in the current evaluation vs. constant material properties in Reference [4]).

Results were also extracted from the vessel portion of the model to verify the accuracy of the results obtained from the ANSYS model, and to check the results due to the use of the 2.0 multiplier on the vessel radius. These results are contained in the file RO PRESSURE.lin. The radius of the finite element model (FEM) was multiplied by a factor of 2.0 [4] to account for the fact that the vessel portion of the axisymmetric model is a sphere, but the true geometry is the intersection of two cylinders.

The equation for the membrane hoop stress in a thin wall sphere is:

0 (pressure)x (radius))

S 2 x th~ickes Considering an actual vessel base metal radius, R, of 105.906 inches increased by a factor of 2.0, a vessel base metal thickness, t, of 5.4375 inches, and an applied pressure, P, of 1,000 psi, the calculated stress for a thin wall sphere is PR/(2t) = 19,477 psi. This compares very well with the remote vessel wall membrane hoop stress from the ANSYS result file, ROPRESSURE.lin, of FileNo.: 0801038.305 Page 6 of 16 Revision: 1 F0306-O1 RO

18,070 psi. Thus, considering the peak total pressure stress of 31,270 psi, the stress concentrating effect of the nozzle blend radius is 31,270/19,477 = 1.61. In other words, the peak nozzle blend radius stress is 1.61 times higher than nominal vessel wall stress for the axisyimnetric model.

The equation for the membrane hoop stress in a thin wall cylinder is:

(radius)

((pressure)x k thickness j" Based on the previous dimensions, the calculated stress for a cylinder without the 2.0 factor is 19,477 psi. Increasing this by a factor of 1.61 yields an expected peak nozzle blend radius stress of 31,358 psi, which would be expected from a cylindrical geometry that is representative of the nozzle configuration. Therefore, the result from the ANSYS file for the peak nozzle blend radius stress (31,270 psi) is close to the peak nozzle blend radius stress for a cylindrical geometry because of the use of the 2.0 multiplier. This is consistent with SI's experience where a factor of two increase in radius is typical for representing the 3-D effect in an axisymmetric model.

4.5 Piping Loads The piping loads were taken from Table 4 of Reference [3]. To determine the piping load stresses, the distances from the applied piping loads to the limiting stress locations were first determined. The limiting stress path locations from Section 4.3 are in the same locations assumed in Table 4 of Reference [3]; this means that no reconciliation of the lengths in Table 4 of Reference [3] is needed.

Reference [3, Section 4.1 ] methodology was used to calculate the piping load stresses. The piping loads and piping load stresses are found in Table 4 and Table 5 of Reference [3].

Table 1: Pressure Stress Intensity Results (1,000 psi)

Membrane plus Total Stress Location Bending Stress Intensity Intensity (psi)

(psi)

Safe End 11,350 11,490 (Path 1 Inside)

Blend (h2nd Radius (Path 2 Inside) 30,540 31,270 FileNo.: 0801038.305 Page 7 of 16 Revision: 1 F0306-01RO

5.0 RESULTS OF ANALYSIS A thennal transient analysis for each defined transient, as well as unit pressure stress and piping interface load analyses were performed for the RO nozzle at Vermont Yankee. All six components of the stress tensor were extracted from the ANSYS model at the two limiting path locations, which are the same two locations previously evaluated [4]. Table 2 provides the unit (1,000 psig) pressure stress analysis results. The unit pressure load results are used to choose the location to analyze at the

  • nozzle blend radius and will be scaled up or down based on applied pressures in the fatigue analysis.

Table 5 of Reference [3] provides the piping stresses at the two critical locations. Table 3 shows an example of thermal stress results. The remaining thermal stress results are contained in the ANSYS output files, listed below, which are saved in the project computer files:

ROPRESSURE.lin: Unit pressure stress analysis results VYRONTRAN]-S.lin: Transient 1, thermal stress analysis results VYRONTRAN2-S.lin: Transient 2, thermal stress analysis results VYRON TRAN3-S.lin: Transient 3, thermal stress analysis results VY RONTRAN4-S.lin: Transient 4, thermal stress analysis results VYRONTRAN5-S.lin: Transient 5, thermal stress analysis results VYRON TRAN6-S. lin: Transient 6, thermal stress analysis results VYRONTRAN7-S. lin: Transient 7, thermal stress analysis results VYRONTRAN8-S.lin: Transient 8, thermal stress analysis results VYRON TRAN9-S. lin: Transient 9, thermal stress analysis results, VYRONTRAN]O-S.lin: Transient 10, thermal stress analysis results VYRONTRAN]1-S.lin: Transient 11, thermal stress analysis results VYRONTRAN12-S.lin: Transient 12, thermal stress analysis results A fatigue calculation using the methodology of Subarticle NB-3200 of Section III of the ASME Code [2] and an enviromnental fatigue usage analysis will be performed in a separate calculation package using the stress results from this calculation.

The results of this calculation are to be used in SI Calculation No. 081038.306, "Fatigue Analysis of Recirculation Outlet Nozzle."

File No.: 0801038.305 Page 8 of 16 Revision: 1 F0306-O1RO

6.0 REFERENCES

1. ANSYS, Release 8.1 (w/Service Pack 1), ANSYS, Inc., June 2004.
2. ASME Boiler and Pressure Vessel Code,Section III, Subsection NB, 1998 Edition with 2000 Addenda.
3. SI Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Confirmatory Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle."
4. SI Calculation No. VY-16Q-305, Revision 0, "Recirculation Outlet Stress History Development for Nozzle Green Function."

File No.: 0801038.305 Page 9 of 16 Revision: 1 F0306-O1RO

VStructural IntegrityAssociates, Inc.

Table 2: Stresses Under Unit Pressure Load, psi Membrane plus Bending Total Node S Sz, S SY Syz Sx x SY Sz Sxy Syz Sxz SE 6395 -955.2 4420 10390 15.26 0 0 -955.2 4912 10530 -222.6 0 0 BR 3829 -718.7 -951.7 25000 4708 0 0 -718.7 206.2 30150 733.2 0 0 FileNo.: 0801038.305 Page 10 of 16 Revision: 1 F0306-01RO

V StructuralIntegrityAssociates, Inc.

Table 3: Example Thermal Stress Result Output, psi Total Transient Node Time Membrane Plus Bending (s) Sx Sy Sz Sxy Syz Sxz Sx Sy Sz Sxy Syz Sxz 0 -33 -3379 196 351 0 0 3539 139 209 0 0 3 -33 -3367 207 351 0 0 3518 160 209 0 0 13 -33 -3340 231 350 0 0 3493 180 208 .0 0 233 180 11400. 12840 210 0 0 180 16290 17350 -536 0 0 2213 -74 -5983 -2660 293 0 0 7056 -3558 322 0 0 2393 149 8475 9884 164 0 0 149 12580 13670 -416 0 0 6773 -51 -4443 -1020 320 0 0 5018 -1463 256 0 0 7193 231 12680 13780 145 0 0 231 17340 18140 -588 0 0 6395 7493 10 -142 2054 221 0 0 10 164 2398 45 0 0 11093 -40 -3276 -654 256 0 0 3669 -954 192 0 0 16457 -47 -4080 -479 352 0 0 4491 -773 244 0 0 16517 -41 -3813 -231 351 0 0 4095 -404 230 0 0 16518 -28 -3689 -110 350 0 0 3383 297 199 0 0 17118 -33 -3241 307 349 0 0 3393 255 204 0 0 17119 3 -2918 623 348 0 0 3 -1521 2098 125 0 0 57120 -33 -3283 279 350 0 0 3439 223 206 0 0 0 3078 2100 4262 554 0 0 3078 4281 5859 577 0 0 3 3078 2100 4262 554 0 0 3078 4280 5856 577 0 0 13 3078 2099 4263 554 0 0 3078 4278 5853 576 0 0 233 823 6811 -8426 -847 0 0 823 12480 38540 5953 0 0 2213 3002 -447 2916 683 0 0 3002 1782 -3944 -735 0 0 2393 799 3298 -10540 -506 0 0 799 9988 25870 4515 0 0 6773 2953 -85 3049 980 0 0 2953 2409 -2931 -397 0 0 7193 1539 6354 -2971 49 0 0 1539 9542 24620 4575 0 0 3829 7493 1642 7294 6946 137 0 0 1642 6282 20660 2675 0 0 11093 2290 364 2825 500 0 0 2290 2225 882 -131 0 0 16457 3195 285 3758 754 0 0 3195 3045 526 -230 0 0 16517 3191 304 3705 753 0 0 3191 3131 687 -181 0 0 16518 3182 300 3699 752 0 0 3182 3120 680 -180 0 0 17118 3157 1120 3848 706 0 0 3157 3802 3273 233 0 0 17119 3127 1109 3832 704 0 0 3127 3771 3247 235 0 0 57120 3077 2085 4216 543 0 0 3077 4274 5877 573 0 0 Note: Not all time steps are listed in this table.

File No.: 0801038.305 Page 11 of 16 Revision: 1 F0306-01RO

U StructuralIntegrity Associates, Inc.

1-, ft WE PRES- NORM xw%

11- ý Figure 1. RO Nozzle Internal Pressure Distribution File No.: 0801038.305 Page 12 of 16 Revision: 1 F0306-OIRO

StructuralIntegrityAssociates, Inc.

....... AN

.......... 2...............

.. ................ ..... ........ ... . .......................

Figure 2. RO Nozzle Pressure Cap Load & Boundary Condition File No.: 0801038.305 Page 13 of 16 Revision: 1 F0306-01 RO

StructuralIntegrityAssociates, Inc.

Figure 3. RO Nozzle Vessel Wall Boundary Condition FileNo.: 0801038.305 Page 14 of 16 Revision: 1 F0306-O1RO

V StructuralIntegrityAssociates, Inc.

I M ,y , = R-.-..;, -R.

Figure 4. Safe End Critical Thermal Stress Intensity Location File No.: 0801038.305 Page 15 of 16 Revision: 1 F0306-O1RO

StructuralIntegrity Associates, Inc.

NODAL SOLUTION AM.N STEp=1

.0114 (AVG~)

DMV4~~9 S3P4

'/4 Figure 5. Nozzle Blend Radius Limiting Pressure Stress Intensity Location Figure 6. Limiting Stress Paths File No.: 0801038.305 Page 16 of 16 Revision: I F0306-O1RO

V StructuralIntegrityAssociates, Inc. File No.: 0801038.306 CALCULATION PACKAGE Project No.: 0801038 Quality Program Z Nuclear E] Commercial PROJECT NAME:

VY Confirmatory Analyses for CS and RO Nozzles CONTRACT NO.:

10163217 Amendment 5 CLIENT: PLANT:

Entergy Nuclear Operations, Inc. Vermont Yankee Nuclear Power Station CALCULATION TITLE:

Fatigue Analysis of Reactor Recirculation Outlet Nozzle D Project Manager Preparer(s) &

Document Affected Revision Description Approval Checker(s)

Revision Pages Signature & Date Signatures & Date 01 - 18 Initial issue.

Gary L. Stevens Tyler Novotny Computer Files 01/07/09 01/07/09 Jennifer E. Smith 01/07/09 1 1-4,6-12, 14-19 Revised per summary ,/ Preparer:

contained in Section 1.1.

LL .'t44 P a Computer Files Changes are marked with "revision bars" in right- Gary L Stevens hand margin. 03/09/09 Tyler D. Novotny 03/09/09 Checker:

William F. Weitze 03/09/09 Page 1 of 19 F0306-OIRO

StructuralIntegrity Associates, Inc.

Table of Contents 1.0 O B JEC TIVE ................................................................................................................................. 3 1.1 Changes Made in Revision I of this Calculation ........................................................... 3 2.0 M ETH OD OLO G Y .............................................................................................................. 3 3.0 D ESIG N IN PU TS ......................................................................................................................... 4 3.1 Stress C alculation .......................................................................................................... 4 3.2 Fatigue Usage Analysis, General ................................................................................... 4 3.3 Event Cycles, VESLFA T .............................................................................................. 5 3.4 Material Properties, VESLFAT ...................................... 5 3.5 Stress Indices .............................................................................................................. ý6 4.0 C A L C U L A TION S ......................................................................................................................... 6 5.0 RESULTS OF AN ALY SIS ..................................................................................................... 7

6.0 CONCLUSION

S AND DISCUSSIONS ............................................................................... 7 7.0 R EFER EN C ES ............................................................................................................................. 8 List of Tables Table 1: Safe End Load Sets as Input to VESLFAT ....................................................................... 9 Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT ....................... I1......

Table 3: Temperature-Dependent Material Properties for VESLFAT (3) ............................ 12 Table 4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves ......................................... 13 Table 5: Pressure and Attached Piping Unit Load Case Stress Components ................................ 14 Table 6: Fatigue Usage Calculation for the Safe End ................................. 15 Table 7: Fatigue Usage Calculation for the Nozzle Blend Radius ................................................. 16 Table 8: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location ....................... 17 Table 9: Linearized Stress Files Compiled for VY-RO-StressResults.xls ...................................... 19 File No.: 0801038.306 Page 2 of 19 Revision: 1 F0306-01RO

VStructural IntegrityAssociates, Inc.

1.0 OBJECTIVE The objective of this calculation package is to perform an ASME Code,Section III fatigue usage evaluation and a plant-specific evaluation of reactor water environmental effects for the reactor pressure vessel (RPV) recirculation outlet (RO) nozzle at the Vermont Yankee Nuclear Power Station.

1.1 Changes Made in Revision 1 of this Calculation Description of changes made in Revision I of this calculation:

a. Editorial changes were made to Table 1 to more precisely describe the transient load sets.
b. All but one of the changes made to Table 2 were editorial to more precisely describe the portions of the transients. The one non-editorial change was to move a time split in Transient 9 to better catch a stress peak or stress valley.
c. Table 3 and the corresponding VESLFAT input file were revised to reflect actual material properties for the safe end. Revision 0 of this calculation tabulated SA-1 82 F304 (18Cr -8Ni) properties, but actually used properties for an Alloy 600 material.
d. Table 5 was changed to eliminate the application ofKt = 1.53 to the nozzle corner piping loads.
e. Tables 6, 7, and 8 were revised to reflect the new fatigue usage and environmental assisted fatigue summaries as a result of the changes associated with Bullets b and c above.
f. Table 8 was revised for editorial changes.
g. The results of various sensitivity studies on fatigue usage were added to Section 5.0.
h. Revision of CUF values in Sections 5.0 and 6.0 to reflect revised analyses.
i. All remaining changes marked throughout this calculation are editorial changes made to the text of the calculation package.

2.0 METHODOLOGY The methodology to be used for this evaluation was established in a previous calculation package

[2]. Based on that methodology, thermal stresses, pressure stresses, and attached piping load stresses were developed in the Reference [1 ] calculation for use in this fatigue calculation. The thermal stresses are added to pressure stresses and attached piping load stresses'. Both the pressure and piping load stresses are scaled based on the magnitudes of the pressure and nozzle fluid temperature during each transient. All six components of the stress tensor from the stress results are used in the fatigue calculation.

Stress components due to piping loads are scaled assuming no stress occurs at an ambient temperature of 70'F and the full values are reached at a reactor design temperature of 575'F [2, Assumption 3.1.7]. In addition, design seismic and deadweight loads are also included and scaled in combination with the thermal loads for each transient. This combination, coupled with assigning the stress due to these loads the same sign as the thermal stress, is considered to be a very conservative treatment of the loads overall in that deadweight and design seismic loads are considered and scaled for every transient.

File No.: 0801038.306 Page 3 of 19 Revision: 1 F0306-01RO

StructuralIntegrity Associates, Inc.

The fatigue calculation is performed for both the limiting safe end and nozzle blend radius locations, as determined in the Reference [1] calculation, and uses the methodology of Subarticle NB-3200 of Section III of the ASME Code [3]. An environmental fatigue usage analysis is also performed in this calculation applying the methodology and associated environmental fatigue multipliers described in Reference [6].

3.0 DESIGN INPUTS 3.1 Stress Calculation Linearized stress components at Node 6395 (limiting safe end path at inside surface) and Node 3829 (limiting nozzle blend radius path at inside surface) are used for the fatigue usage calculation, as shown in Figure 6 of Reference [1]. For the nozzle blend radius location, the stresses used in the evaluation are for the base metal only; that is, the cladding material is unselected prior to stress extraction. The stress components from the thermal stress analyses are combined with stress components due to pressure and piping loads. The linearized thermal stress components for each transient are taken from the relevant output files in the Reference [1] calculation (a sample of which was provided in Table 3 of Reference [1]). The unit pressure stress component results are taken from Table 2 of Reference [1]. Piping load stress components are taken from Table 5 of the Reference [2] calculation.

3.2 Fatigue Usage Analysis, General Structural Integrity's VESLFAT program [4] is used to perform the fatigue usage calculation in accordance with the fatigue usage portion of ASME Code,Section III, Subarticle NB-3200 [3].

VESLFAT performs the analysis required by NB-3222.4(e) [3] for Service Levels A and B conditions defined by the user. The VESLFAT program computes the primary-plus-secondary and total stress ranges for all events and performs a correction for elastic-plastic analysis, if necessary.

The program computes the stress intensity range based on the stress component ranges for all event pairs [3, NB-3216.2]. The program evaluates the stress ranges for primary-plus-secondary and primary-plus-secondary-plus-peak stresses based on all six components of stress (3 normal and 3 shear stresses). If the primary-plus-secondary stress intensity range is greater than 3 Sm, the total stress range must be increased by the simplified elastic-plastic strain correction factor, Ke, as described in NB-3228.5 [3]. The design stress intensity, Sm, is specified as a function of temperature. The input maximum temperature for both states of a load set pair is used to establish the S,, value used in the fatigue calculations from the user-defined input values.

When more than one stress set is defined for either of the event pair loadings, the stress differences are determined for all of the potential stress pairs, and the pair producing the largest alternating total stress intensity (Salt), including any effects of Ke, is used. The principal stresses for the stress ranges are determined by solving for the roots of the following cubic equation2:

S3 _ (Tx -+- yY+ O-z)S2 + (C3x Cy -+ C7 a, z + a,-7 - ,y2 _ Sxz2 _ Syz2)s 2Note that cy., ay, az, etc. are used synonymously with Sx, S,, S,, etc., in this calculation.

File No.: 0801038.306 Page 4 of 19 Revision: 1 F0306-OIRO

VStructural IntegrityAssociates, Inc.

- (Cy"Gy a, + 2 rxy Tz "*yz - CTz Ty2 _ *y , 2 _ Cx TyZ2 o The stress intensities for the event pairs are reordered in decreasing order of Sait, including a correction for the ratio of modulus of elasticity (E) from the fatigue curve divided by E from the material evaluated at the maximum event temperature. This allows a fatigue table to be created to eliminate the number of cycles available for each of the transient events. This fatigue table is based on a worst-case progressive pairing of events in order of the most severe alternating stress to the least severe, allowing determination of a bounding fatigue usage per NB-3222.4(e) [3]. For each load set pair in the fatigue table, the allowable number of cycles is determined based on Salt.

3.3 Event Cycles, VESLFAT For the Vermont Yankee RO nozzle analysis, transients that consist of combined stress peaks or valleys are split so that each successive peak or valley is treated separately. Therefore, there are 61 load sets based on the combined stress changes for the safe end, and 46 load sets based on the combined stress changes for the nozzle blend radius location. The reason the number of load sets are not equal for each path is because the time history stress results of those paths differ. Tables 1 and 2 show the load sets applicable to plant operation, with cycle counts per Table I of Reference [2].

These are used as input to VESLFAT for the safe end and nozzle blend radius locations, respectively. The cycle counts of Reference [2, 7] consider 60 years of operation. The data from Table 1 is entered into the VESLFAT input files VY-RO-VFAT-1i.CYC (safe end) and the data from Table 2 is entered into the file VY-RO- VFAT-21. CYC (nozzle blend radius).

3.4 Material Properties, VESLFAT Material properties are entered in VESLFAT input files VY-RO-VFAT-]I.FDT (safe end) and VY-RO-VFAT-2I.FDT (nozzle blend radius). Table 3 lists the temperature-dependent material properties used in the analysis [5]. Table 4 lists the fatigue curve for the nozzle blend radius and safe end materials

[3, Appendix I, Table 1-9.1 and Figure 1-9.1 (UTS < 80.0 ksi) for the nozzle blend radius, and Tables 1-9.1 and 1-9.2.2 (Curve C) and Figures 1-9.2.1 and 1-9.2.2 for the safe end location]. Curve C is selected for the safe end location because it is the most conservative curve among the three extended curves for austenitic steel. VESLFAT automatically scales the stresses by the ratio of E on the fatigue curve to E in the analysis, for the purposes of determining allowable numbers of cycles, as required by the ASME Code.

Other material properties are input as follows:

m = 1.7, n = 0.3, parameters used to calculate Ke for the safe end location [3, Table NB-3228.5(b)-1]

m = 2.0, n = 0.2, parameters used to calculate Ke for the nozzle blend radius location [3, Table NB-3228.5(b)-1]

E from fatigue curve = 28,300 ksi [3, Appendix 1, Figure 1-9.2] for the safe end location.

E from fatigue curve = 30,000 ksi [3, Appendix I, Figure 1-9.1] for the nozzle blend radius location.

File No.: 0801038.306 Page 5 of 19 Revision: 1 F0306-OIRO

StructuralIntegrityAssociates, Inc.

3.5 Stress Indices The limiting stress path for the RO nozzle safe end is defined in Reference [1]. The stresses caused by the piping were hand calculated and do require a stress concentration factor, if appropriate. The stress concentration factor for the safe end location is 1.53 [2, Section 3.8]. This value is conservatively used for both the C2 and K2 values required by the ASME Code [3, NB-3600]. The piping loads are relatively minor in comparison to the other loads this nozzle experiences so the conservative C2 and K2 values will have a small impact on the analysis. Table 5 shows the piping loads after applying the C2 and K2 values as appropriate.

4.0 CALCULATIONS Table 5 contains the stress components at the locations of interest for the 1,000 psi unit pressure stress case [1, Table 2]. Table 5 also contains the stress components for the attached piping load unit stress case [2, Table 5], which correspond to a reactor design temperature of 575°F [2, Section 3.1.7].

The attached piping load stress components were applied assuming the same signs as the thermal stress, which yields the largest stress component ranges.

The calculations of all of the VESLFAT stress inputs are automated in Excel workbooks VY-RO-VFAT-li.xls (safe end) and VY-RO-VFAT-2i.xls (nozzle blend radius). These files are organized with sheets labeled as follows:

  • Overview: Contains general information.
  • Other Stresses: Contains pressure and attached piping load stresses. As shown in Table 5, the pressure stresses use the membrane-plus-bending and total stress from the finite element analysis [1].
  • Rearranger: There are 12 Rearranger sheets, one for each thermal transient as analyzed by ANSYS. In these sheets, thermal stresses are copied from Excel workbook VY-RO-StressResults.xls, and rearranged to conform to VESLFAT input format (including switching the shear stress components Sx, and Sy, as required by VESLFAT). VY-RO-StressResults.xls contains the results of the ANSYS stress linearization for each transient. The files contained within this workbook are shown in Table 9. Time-varying scale factors for the attached piping loads (based on path metal temperature) and pressure are determined, and used to scale the unit load case stresses, which are then added to the thermal stresses. Since the attached piping loads can act in any direction, the stresses due to the attached piping loads are assigned the same sign as the thermal stresses to maximize the component stresses.

Algebraic summation of all six stress components is performed for pressure, piping loads, and thermal stresses at each transient time step. The VESLFAT stress input also includes time-varying metal temperature, as obtained from the ANSYS output, which is used to determine temperature-dependent properties from the values in Table 3.

  • VESLFAT: Contains the VESLFAT stress input, as obtained from the Rearranger sheets.

Load set numbers are entered on this sheet, as defined in Table 1 and Table 2. These sheets are saved to VESLFAT input files VY-RO-VFAT-li.STR (safe end) and VY-RO-VFAT-2i.STR (nozzle blend radius).

File No.: 0801038.306 Page 6 of 19 Revision: I F0306-O1RO

StructuralIntegrity Associates, Inc.

5.0 RESULTS OF ANALYSIS Table 6 and Table 7 provide the detailed calculated 60-year fatigue usage, as obtained from VESLFAT output files VY-RO-VFAT-11.FAT (safe end) and VY-RO-VFAT-2LFAT (nozzle blend radius). All VESLFAT input and output files are saved in the project computer files associated with this calculation.

From Table 6, the safe end cumulative usage factor (CUF) is 0.00308 for 60 years. From Table 7, the nozzle blend radius CUF is 0.0 175 for 60 years.

From Table 1 of Reference [6], it was determined that hydrogen water chemistry (HWC) is available for 47% of the total 60-year operating period, and normal water chemistry (NWC) is present for the remaining 53% of the total 60-year operating period. From Table 1 of Reference [6], the dissolved oxygen values for the recirculation line (which is applicable to the RO nozzle) are 48 ppb for HWC conditions and 122 ppb for NWC conditions.

For the stainless steel piping, the environmental fatigue factors for post-HWC and pre-HWC are 15.35 and 8.36 from Table 2 of Reference [6]. The overall environmental multiplier is found by (15.35 x 47% + 8.36 x 53%), which equals 11.645, conservatively rounded upto 11.7. Therefore, the overall environmental multiplier is 11.7, which results in an EAF adjusted CUF of 11.7 x 0.00308 0.0360 for 60 years, which is acceptable (i.e., less than the allowable value of 1.0).

Based on the detailed CUF calculation shown in Table 7, a detailed EAF adjusted CUF evaluation on a load-pair basis is provided for the nozzle blend radius location in Table 8. The EAF usage from Table 8 is 0.111 for 60 years, which is less than the allowable value of 1.0 and is therefore acceptable. The effective overall Fen is 0.111/0.0175 = 6.32.

As a part of fatigue analysis calculations, it was noted that using Fy = -20 kips in the piping loads caused a slightly higher total stress intensity. However, the change was determined to have an insignificant effect on fatigue usage results. In addition, the effect of modeling the distinct material properties of both Type F304 and Type F316 in the ANSYS analysis (as opposed to using 18Cr-8Ni properties) was determined to have an insignificant effect on fatigue usage results. Finally, the effect of applying a minimum temperature of 130'F for thermal boundary Region 2 (see Figure 1 of Reference [2]) was determined to have an insignificant effect on fatigue usage results. These investigations and associated results are contained in the project files.

6.0 CONCLUSION

S AND DISCUSSIONS Detailed fatigue calculations for the Vermont Yankee RO nozzle were performed based on the results of stress analyses previously performed [1]. The thermal stresses were combined with stresses due to pressure and attached piping loads, both of which were scaled based on the magnitudes of the pressure and metal temperature during each thermal transient. All six components of the stress tensor were used for the fatigue calculations. The fatigue calculations were performed at previously-determined limiting locations in the safe end and nozzle blend radius, and used the methodology of Subarticle NB-3200 of Section III of the ASME Code [3].

File No.: 0801038.306 Page 7 of 19 Revision: 1 F0306-O1RO

StructuralIntegrity Associates, Inc.

The 60-year CUT for the safe end location was'determined to be 0.00308 and the CUF for the nozzle blend radius location was determined to be 0.0175. Both values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.

Detailed EAF assessments were also performed for the two RO nozzle locations. The 60-year EAF CUF for the safe end location was determined to be 0.0360. The 60-year EAF CUF for the nozzle blend radius location was determined to be 0.111 using temperature-dependent Fen multipliers for each load pair. Both values are less than the ASME Code allowable value of 1.0, and are therefore acceptable.

7.0 REFERENCES

1. Structural Integrity Associates Calculation No. 0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle."
2. Structural Integrity Associates Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle."
3. ASME Boiler and Pressure Vessel Code,Section III, 1998 Edition with 2000 Addenda.
4. VESLFAT, Version 1.42, 02/06/07, Structural Integrity Associates.
5. ASME Boiler and Pressure Vessel Code,Section II, Part D-Properties, 1998 Edition with 2000 Addenda.
6. SI Calculation No. VY-16Q-303, Revision 0, "Environmental Fatigue Evaluation of Reactor Recirculation Inlet Nozzle and Vessel Shell/Bottom Head."
7. Entergy Design Input Record (DIR) EC No. 1773, DIR. Revision 1, "Environmental Fatigue Analysis for Vermont Yankee Nuclear Power Station," 7/26/07, SI File No. VY-1 6Q-209.
8. Deleted (not used in this calculation).

File No.: 0801038.306 Page 8 of 19 Revision: 1 F0306-OIRO

StructuralIntegrity Associates, Inc.

Table 1: Safe End Load Sets as Input to VESLFAT VESLFAT Start ties Transient Time, see Temp Change Pressure Change Cycles Load Set 1 lTrnl 0 Up Up 300 2 2Tml 1616.4 Up Up 300 3 1Tm2 0 Down None 300 4 2Trn2_ 0.4 Down None 300 5 3Trn2 301 Down None 300 6 4Trn2_ 601.4 Down None 300 7 1Trn3 0 Up None 10 8 2Trn3 250 Up None 10 9 3Tm3_ 2050 Down None 10 10 4Tm3_ 2960 Up & Down None 10 11 5Trn3_ 5560 Down None 10 12 lTrn4_ 0 None Up 10 13 2Trn4 2 None Up & Down 10 14 3Trn4_ 7 Down Down 10 15 4Tm4_ 46 Down & Up None 10 16 5Tn4_ 992 Up & Down Down 10 17 6Tin4 2294 Down & Up Down & Up 10 18 7Trn4_ 3050 Up & Down Up & Down 10 19 8Trn4_ 6899 Down & Up Down 10 20 9Trn4 7745 Up Down 10 21 1OTm4_ 8645 Up Down 10 22 11Trn4_ 11057 Up Up 10 23 12Tin4 16166 Up & Down Up 10 24 13Tm4_ 16818 None None 10 25 14Trn4 17118 Down None 10 26 1Tn5_ 0 None Up 60 27 2Trn5 1.5 None Up & Down 60 28 3Trn5 24 Up Down & Up 60 29 4Trn5 2310 Down None 60 30 5Trn5 2611 None None 60 31 6Trn5 2911.4 Down None 60 32 1Trn6 0 None Up 1 33 2Trn6 0.6 None Up & Down 1 34 3Trn6 20 Up Down & Up 1 35 4Trn6_ 2312 Down None 36 5Tm6_ 2613 None None 37 6Tin6 2913.6 Down None File No.: 0801038.306 Page 9 of 19 Revision: I F0306-O1RO

VStructural IntegrityAssociates, Inc.

Table 1 (continued): Safe End Load Sets as Input to VESLFAT VESLFAT Start ties Transient Time, see Temp Change Pressure Change Cycles Load Set 38 lTmn7 0 Down Down 39 2Trn7 37.5 Down Down 40 3Trn7 600 Down Down 41 4Trn7 4443 Down Down 42 1Trn8 0 None Down 228 43 2Tm8_ 3 Up Down & Up 228 44 3Trn8_ 2295 Down None 228 45 4Trn8 3927 None None 228 46 1Trn9 0 Down None 47 2Trn9 0.12 Down & Up None 48 3Trn9 27.92 Up None 49 4Trn9 290.15 None None 50 1TmlO_ 0 Down Down 300 51 2Trnm0 730.8 Down Down 300 52 3TmlO_ 6314 Down Down 300 53 4Tm 10 6844 Down Down 300 54 5TrnlO 9555 Down Down 300 1

55 6TrnlO 14937 Down Down 300 10 56 1Trnl 1 0 None None 120 57 2Tml 1- 0 None Up 120 58 3Trnl 1 0 None Down 120 59 1Trnl2 0 None None 1 60 2Trnl2 0 None Up 61 3Trnl2 0 None Down File No.: 0801038.306 Page 10 of 19 Revision: 1 F0306-0IRO

V StructuralIntegrity Associates, Inc.

Table 2: Nozzle Blend Radius Load Sets as Input to VESLFAT Start VESLFAT Transient Time, Temp Change Pressure Change Cycles Load Set sec 1 1Tml 0 Up Up 300 2 2Tml 808.2 Up Up 300 3 1Trn2 0 Down None 300 4 2Trn2_ 0.4 Down None 300 5 3Trn2_ 401 Down None 300 6 1Trn3_ 0 Up None 10 7 2Trn3 250 Up & Down None 10 8 3Trn3 2325 Down & Up None 10 9 4Trn3_ 3510 Up & Down None 10 10 5Trn3_ 5060 Down None 10 11 1Trn4_ 0 None Up 10 12 2Trn4_ 2 None Up & Down 10 13 3Trn4_ 7 Down Down 10 14 4Trn4_ 46 Down & Up None 10 15 5Trn4_ 1091 Up & Down Down 10 16 6Trn4_ 2348 Down & Up Down & Up 10 17 7Trn4_ 3269 Up & Down Up & Down 10 18 8Tm4_ 6983 Down & Up Down 10 19 9Trn4_ 7745 Up Down & Up 10 20 1OTrn4_ 13839 Up & Down Up 10 21 l1Trn4_ 16918 Down None 10 22 12Tn4_ 18986 None None 10 23 1Tn5_ 0 None Up & Down 60 24 2Tn5_ 24 Up & Down Down & Up 60 25 3Trn5_ 2611 Down None 60 26 1Trn6_ 0 None Up 1 27 2Tm6_ 0.6 None Up & Down 1 28 3Trn6_ 20 Up & Down Down & Up 29 4Trn6_ 2663 Down None 30 lTrn7 0 Down Down 31 2Trn7_ 37.5 Down Down 32 3Trn7_ 2247 Down Down 33 1Trn8 0 None Down 228 File No.: 0801038.306 Page 11 of 19 Revision: 1 F0306-0IRO

StructuralIntegrity Associates, Inc.

Table 2 (continued): Nozzle Blend Radius Load Sets as Input to VESLFAT Start VESLFAT Transient Time, Temp Change Pressure Change Cycles Load Set sec 34 2Trn8_ 3 Up & Down Down & Up 228 35 3Trn8_ 2025 Down None 228 36 1Trn9_ 0 Down None 1 1

37 2Trn9_ 9 Up None 38 3Trn9_ 58 None None 1 39 0 Down Down 300 1I1Tml0I Trnl 0 40 2Tml0 313.2 Down Down 300 41 1Trnl 1 0 None None 120 42 0 None Up 120 3Trnll 120 43 0 None Down 44 1Trnl2 0 None None 1 45 2Trnl2_ 0 None Up 1 46 3Trnl2_ 0 None Down 1 Table 3: Temperature-Dependent Material Properties for VESLFAT (3)

Material T, 'F E x 106, psi S., ksi Sy, ksi SA-508 Class 2 70 27.8 26.7 50.0 (nozzle blend radius(2)) 200 27.1 26.7 47.0 300 26.7 26.7 45.5 400 26.1 26.7 44.2 500 25.7 26.7 43.2 600 25.2 26.7 42.1 SA-182 F316 70 28.3 20 30 (Safe End (1)) 200 27.6 20 25.9 300 27.0 20 23.4 400 26.5 19.3 21.4 500 25.8 18.0 20.0 600 25.3 17.0 18.9 Notes:

1. For the safe end material, SA-182 F316 (16Cr- 12Ni- 2Mo) austenitic stainless steel properties are used.
2. For the nozzle blend radius material, SA508 Class 2 material properties are used (3/4Ni-1/2Mo-1/3Cr-V), per Reference [2].
3. All values are taken from Reference [5].
4. SA-508 Class 2 in the Code of Construction is the same as SA-508 Gr. 2 Class 2 in the 1998 ASME Code [5].

File No.: 0801038.306 Page 12 of 19 Revision: I F0306-0IRO

StructuralIntegrity Associates, Inc.

Table 4: Carbon/Low Alloy Steel and Stainless Steel Fatigue Curves Sa, ksi Sa, ksi Number of Cycles Carbon/Low Alloy (1) Austenitic 10 580 708 20 410 512 50 275 345 100 205 261 200 155 201 500 105 148 1000 83 119 2000 64 97 5000 48 76 10000 38 64 20000 31 55.5 50000 23 46.3 100000 20 40.8 200000 16.5 35.9 500000 13.5 31 1000000 12.5 28.2 2.E+06 N/A 22.8(2) 5.E+06 N/A 18.4(2) 1.E+07 N/A 16.4(2) 2.E+07 N/A 15.2(2)

]4.3 (2) 5.E+07 N/A 1.E+08 N/A 14.1(2) 1.E+09 N/A 13.9(2) 1.E+10 N/A 13.7(2) 1.E+1I N/A 13.6(2)

Note:

1. Using UTS _ 80 ksi curve.
2. Using Curve C for austenitic steel.

File No.: 0801038.306 Page 13 of 19 Revision: 1 F0306-OIRO

VStructural Integrity Associates, Inc.

Table 5: Pressure and Attached Piping Unit Load Case Stress Components Node Membrane plus Bending (1) Total (1) t 5 t 5 d(2) SY S S, yz S" SY. S z Sx Sxz ) SyZ )

Pressure (3) 6395 -955.2 4420 10390 15.26 0 0 -955.2 4912 10530 -222.6 0 0 3829 -718.7 -951.7 25000 4708 0 0 -718.7 206.2 30150 733.2 0 0 4

ping( ) 6395 0 7930 0 831 2066 0 0 12133 0 1271 3160 0 3829 0 218 0 42 49 0 0 218 0 42 49 0 Nuotes: I. All stress values are in uILts o psI.

2. The safe end location is represented by Node 6395, and the nozzle blend radius location is represented by Node 3829.
3. The stresses for both nodes represent the stress due to an applied pressure of 1,000 psig.
4. Piping stresses for both locations represent the stress due to full attached piping loads at an RPV temperature of 575'F.
5. Syz and S_ components have been rearranged from the ANSYS output in order to be in correct order for VESLFAT.

File No.: 0801038.306 Page 14 of 19 Revision: 1 F0306-0IRO

StructuralIntegrity Associates, Inc.

Table 6: Fatigue Usage Calculation for the Safe End Load Desc. Load Desc. Salt

  1. a #1 #2 #2 n (cycles) Sn (psi) Ke Si) Nallow
  1. 1 #1 #2 #2 (psi) U 47 2Trn9 48 3Trn9_ 1 79715 2.62 169777 331.52 0.00302 15 4Trn4_ 49 4Trn9_ 1 30275 1 23722 1757500 0.00000 15 4Trn4_ 28 3Trn5 9 29755 1 23610 1784800 0.00001 19 8Trn4 28 3Trn5 10 26926 1 21352 2647400 0.00000 17 6Trn4_ 28 3Trn5_ 10 25213 1 20492 3155800 0.00000 28 3Trn5_ 39 2Trn7_ 1 20321 1 16926 8269400 0.00000 18 7Trn4 28 3Trn5_ 10 19961 1 16731 8866300 0.00000 28 3Trn5 44 3Trn8_ 20 4606 1 16450 9819700 0.00000 34 3Trn6_ 44 3Trn8 1 4606 1 16450 9819700 0.00000 43 2Trn8_ 44 3Trn8_ 207 4606 1 16450 9819700 0.00002 6 4Trn2_ 43 2Trn8_ 21 4028 1 16176 11335000 0.00000 6 4Trn2_ 35 4Trn6_ 1 3519 1 15752 14441000 0.00000 6 4Trn2 29 4Trn5 60 3484 1 15637 15446000 0.00000 6 4Trn2_ 22 11Trn4_ 10 11783 1 15613 15666000 0.00000 6 4Trn2_ 23 12Trn4_ 10 3202 1 15588 15895000 0.00000 2 2Trnl_ 6 4Trn2_ 198 3193 1 15583 15936000 0.00001 2 2Trnl 31 6Trn5 60 3319 1 15531 16430000 0.00000 2 2Trnl 37 6Trn6 1 3319 1 15531 16430000 0.00000 2 2Trnl1 25 14Trn4_ 10 1702 1 15055 23098000 0.00000 2 2Trnl_ 40 3Trn7_ 1 18894 1 14987 24732000 0.00000 2 2Trnl_ 16 5Trn4_ 10 5069 1 14487 41157000 0.00000 33 2Trn6 52 3Trnl_0 1 12380 1 14460 42317000 0.00000 13 2Trn4 52 3Trnl0 10 10470 1 13875 1.336E+09 0.00000 50 1Trnl0_ 52 3Trnl0_ 289 9634 1 13841 1.968E+09 0.00000 50 1TrnlO 53 4Trnl0 11 18796 1 13770 4.465E+09 0.00000 3 1Trn2 53 4Trnl0 289 18795 1 13769 4.491E+09 0.00000 Total 0.00308 Usage =

Note: All other load pairs have an alternating stress, Saft, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.

File No.: 0801038.306 Page 15 of 19 Revision: I F0306-O1RO

V StructuralIntegrity Associates, Inc.

Table 7: Fatigue Usage Calculation for the Nozzle Blend Radius Load Desc. Load Desc. n Salt Nallow U

  1. 1 #1 #2 #2 (cycles) S (psi) Ke (psi) 1Trnl1 14 4Trn4_ 10 21902 1.00 43085 6889 0.0015 1Trnl_ 37 2Trn9_ 1 21390 1.00 32177 17617 0.0001 12 1Trn1_ 16 6Trn4_ 10 15100 1.00 31137 19701 0.0005 1 1Trnl_ 27 2Trn6_ 1 42381 1.00 27020 30496 0.0000 2 2Trnl_ 45 2Trn12_ 1 45773 1.00 26852 31084 0.0000 1 1Trnl_ 15 5Trn4_ 10 18457 1.00 26707 31604 0.0003 2 lTrnl_ 18 8Trn4_ 10 13066 1.00 26562 32139 0.0003 1 1Trnl_ 36 1Trn9_ 1 28617 1.00 24546 40947 0.0000 2 34179 1.00 24042 43643 0.0002 1 1Trn1_ 13 3Trn4_ 10 1 1Trnl_ 38 3Trn9_ 1 25904 1.00 23939 44218 0.0000 1 1Trn1_ 12 2Trn4_ 10 36762 1.00 23612 46129 0.0002 1 1Trnl_ 23 1Trn5_ 60 35051 1.00 22617 54348 0.0011 11 1Trn1_ 17 7Trn4_ 10 22210 1.00 22533 55358 0.0002 2 1Trnl_ 5 3Trn2_ 166 29847 1.00 22312 58126 0.0029 2 2Trnl_ 5 3Trn2_ 134 29301 1.00 22309 58168 0.0023 2 2Trnl_ 28 3Trn6_ 1 33856 1.00 22227 59234 0.0000 2 2Trn 1 11 1Trn4_ 10 33460 1.00 21959 62919 0.0002 2 2Trnl1 26 1Trn6_ 1 32908 1.00 21661 67330 0.0000 2 2Trnl_ 25 3Trn5_ 68 29068 1.00 21226 74454 0.0008 2 2Trnl1 29 4Trn6_ 1 29068 1.00 21226 74454 0.0000 2 2Trnl1 8 3Trn3_ 10 29847 1.00 21214 74661 0.0001 2Trnl_ 4 2Trn2_ 82 30245 1.00 21092 76819 0.0011 4 2Trn2_ 41 1Trn 11 120 32229 1.00 20851 81328 0.0015 4 2Trn2_ 32 3Trn7_ 1 30983 1.00 20125 96967 0.0000 4 2Trn2_ 40 2Trn 10_ 97 30982 1.00 20124 96981 0.0010 10 5Trn3_ 40 2Trn 10_ 10 31344 1.00 20033 99198 0.0001 35 3Trn8_ 40 2Trn 10_ 193 29931 1.00 19888 102050 0.0019 35 3Trn8_ 43 3Trnl 1_ 35 29651 1.00 19696 105678 0.0003 9 4Trn3_ 43 3Trn 11_ 10 30915 1.00 19357 112494 0.0001 7 2Trn3_ 46 3Trn12_ 1 30523 1.00 19349 112655 0.0000 7 2Trn3_ 44 1Trn12_ 1 30523 1.00 19349 112655 0.0000 7 2Trn3_ 43 3Trn 11 8 30523 1.00 19349 112655 0.0001 3 1Trn2_ 43 3Trn 11_ 67 31236 1.00 19331 113042 0.0006 3 1Trn2_ 19 9Trn4_ 10 23810 1.00 16958 181219 0.0001 31 2Trn7_ 42 2Trnl I 1 27376 1.00 11515 infinite 0.0000 Total 0.0175 Usage =

Note: All other load pairs have an alternating stress, Salt, that is below the endurance limit of the fatigue curve. Therefore, they do not contribute to fatigue usage.

File No.: 0801038.306 Page 16 of 19 Revision: 1 F0306-O1RO

StructuralIntegrity Associates, Inc.

Table 8: EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location VY RO flozzle Corner Environmental Fatique Calculation CUF Calculation from file NrY-RO-VFAT-2i.fat:

Index Load.#1: Description#1 1 (cycles)(5 Load#21Description#2':n2Icycles)(5) (cycles) (5: Sr,(pi) K S.(psi) 1`.1 U S I Trn_ 300 14 i 4Trn4_

4 10 10 21902 1.00 43085 6889 0.0015 2 1Trn1_ 290 3r 2Trn9 1 1 21390 1.00 32177 17617 0.0001 3 1 1Trnl I 289 16 i 6Trn4_ 10 10 15100 1.00 31137 19701 0.0005 4 1 lTrnl 279 27 2Trn6 i 1 1 42381 1.00 .27020 30496 0.0000 5 2 27rnl 30G 451 2Trn 12 1 45773 1.00 26852 31054 0.0000 6 1 1Trnl_

l -78 18s 5Trn_4 i 10 10 18457 1.00 26707 31604 0,0003 7 1 1Trnt 268 18 i 8Trn4_ i 10 10 13066 1.00 26562 32139 0.0003 8 1n 125nl L8 36 1Trn9 1 1 28617 1.00 24546 40947 0.0000 9 '1 lTrn i 257 13 3Trn 4- 10 10 34179 1.00 24042 43643 0.0002 10 1i 1Trnl_ 247 38 3Trn 9_ 1 1 25904 1.00 23939 44218 0.0000 11 1 Trl 246 12 1 2Trn4 10 10 36762 1.00 23,612 46129 0.0002 12 1 Trnl 2 23 I1Trn5_ i 60 60 35051 1.00 22617 4348 0.0011 13 1 ITrnl 176 17 7Trn_ 10 10 22210 1.00 22533 55358 0.0002 14 1 ITrnl 16,6 3Trn2 300 166 29847 1.00 22312 58126 0.0029 15 :2 2Trnl 299 5 3Trn2 134 134 29301 1.00 22309 E5168 0.0023 16 2 27rnl 165 28 3Trn6 1 1 33856 1.00 22227 59234 0.0000 17 2 .2Trnl 1 1S4 11 1Trn4 1 10 10 33460 1.00 21959 62919 0.0002 18 2 2Trnl 1 26 1 rn6 1 1 32908 1.00 21661 67330 0.0000 19 2 2Trnl1 153 25 3TrnS 60 60 29068 1.00 21226 74454 0.0008 20 2 2T rn i 93 29 dTrn6_ 1 1 29068 1.00 21226 74454 0.0000 21 2 27rnl R2 8 i 3Trn3 10 10 29847 1.00 21214 74661 0.0001 22 2 2Trnl 82 4 2Trn2 300 82 30245 1.00 21092 76819 0.001.1 23 4 m 2rn2_ 218 41 1 1Trn11- 1 120 120

  • 32229 1.00 20851 81328 0.0015 24 4 2Trn2 98 32 3Trn7 1 1 30983 1.00 20125 06967 0.0000 25 .4 2Trn2 Q7 40 1 O 2Trnl10- 300 97 30082 1.00 20124 n- 1 0.0010 26 10 5Trn3 10 do 2Trn10_ i 203 10 31344 1.00 20033 99198 0.0001 27 35 7 mTrn 228 40 2Trn 10 193 193 29931 1.00 19589 102050 0.0019 28 35- 3Trn_ 35 43 3Trnh1 120 35 29651 1.00 19698 105678 0.0003 29 9 4Trn3 10 43 3Trn11 1 85 10 30915 1.00 19357 112494 0.0001 4

30 7 2Trn3 10 3Trn12 i 1 1 30523 1.00 19349 112655 0.0000 31 7 2Trn3 9 44 1Trn12i 1 1 30523 1.00 19349 112655 0.0000 32 7 2Trn3 8 43 J3Trnl1 75 8 30523 1.00 19349 112655 0.0001 33 3 lTrn2 300 43 3Trn11 67 67 31236 1.00 19331 113042 0.0006 34 3 tTrn2 233 19 9Trn4 i 10 10 23810 1.00 16958 181219 0.0001 35 , 31 2Tmn_ 1 42 2T1rn1_ 1 120 1. 27376 1.00 11515 infinte 0.0000 Total, U = 0.0175 File No.: 0801038.306 Page 17 of 19 Revision: 1 F0306-O1RO

Structural Integrity Associates, Inc.

Table 8 (continued): EAF Fatigue Usage Calculation for the Nozzle Blend Radius Location EAF Calcuatina IIWC DO rIlVLC 00 ndW8~,"uskumTh I.'4.r~/FI 48 122 ppb Transient Maximum Temperatures:  % HWC= 47% 53% =% IIWc

~'~iY..OA..~JFAT.Ji ~i I TMAX (TF)(1) TMAX (-1 Fen (Z)

(3)

Uanv (3) -

Index Load #1I Desc. #1 Load #2 Desc #2 Line# T 1(4) st1(4 72(4) s2 (4) Sn (psi) T Fi)(1) Uenv 1 1 lTrnl_ 14 4Trn4 176 "1 3 14 18 21902 339 2 1 ITrnl 37 2Trn9_ 6065 / 3 37 62 21390 437 3 1 ITrnl _ 16 6Trne_ 1060 I 3 16 7 15100 329 4 1 1Trn 1 27 2Trn6_ 3734 1 3 27 8 42301 526 5 2 2Trnl_ 45 2Trn12 20'1558 2 1 45 1 45773 120 2.45 6 1 iTrno 15 is 5Tro4 4 1927 1 3 15 49 13457 394 201 2-45 4.46 0.001 7 1Trnn 10 -

0Trn 223M I 3 18 10 1300* 335 335 100 2.45 3.04 0.001 8 I 1Trn 1 36 1Trn_ 5657 1 3 3M 41 20617 405 495 257 2.45 0.50 0.000 9 1 1Trn I 13 3Trn 4 1651 1 3 13 15 34179 516 516 269 2.45 9.03 0.001 10 1 iTrnl _ 30 3-rnS 6657

- I 3 38 1 25904 490 490 254 2.45 8.31 0U000 4 526 274 2.45 10.49 0.001 11 I ITrnl 12 2Trn _ 1599 1 3 12 3 36762 526 12 1 1Trnl_ 23 1Trn5 311t5 1 3 23 27 35051 526 520 274 2.45 10.49 0.007 13 1 1Trnl_ 17 7Trn4 2152 1 3 17 5& 22210 426 426 219 2.45 5.4. 0.001 14 1 ITrnl_ 5 3Trn2_ 952 1 3 5 80 29847 530 530 277 2.45 10.76 0.020 15 2 2TrnI 1 ITrr2_ 8718 2 1 5 79 29301 530 530 277 2.45 10.76 0.016 16 2 2Trn1l 20 5Trno_ 9R727 2 1 28 1 33856 526 526 274 2.45 10.49 0.000 17 2 2Trn 1 _ 11 ITrn4 _ 42455 2 1 11 4 33460 526 526 274 2.40 10.49 0.001 18 2 2Trn1_ 26 ITrn6_ 98465 2 1 26 3 32900 526 52, 274 2.45 10.49 0.000 2Trn I_ 25 3irn5 89557 2 1 25 22 29068 529 520 276 2.45 10.60 0.005 19 2 20 2 2Trn I 29 4Trn_ 105503 2 1 29 21 29060 529 520 276 2.45 10.69 0.000 21 2 2Trn 1 8 3Trn3_ 35.741 2 1 8 5 29047 528 520 276 2.45 10.63 0.001 T 204 2.45 11.71 0.008 22 2 2 rnl_ 4 2Trn2_ 7777 2 1 4 7 30245 5-43 543 23 4 2Trn2 41 1Trnl 233450 4 7 41 1 32229 543 543 204 2.45 11.71 0.011 24 4 2Trn2 32 3Trn7_ 223647 4 7 32 126 30983 543 543 204 2.45 11,71 0.000 543 543 2M4 2.45 11.71 0.007 25 4 2Trn2_ 40 2-r7ln10- 232587 4 7 40 209 30982 26 '10 5Trn 3 40 2Trnl 0 1138571 10 21 40 209 31344 527 527 275 2.45 10.56 0.001 27 35 3TrnO 40 2Trn10_ 28?1140 35 51 40 209 2S931 528 520 276 2.45 10.63 0.013 20 35 3Trn. 43 3Trohl _ 2910647 35 51 43 1 29651 520 528 276 2.45 10.63 0.002 29 9 4Trn_ 43 3Trn 11- 106932C C 28 43 1 30915 536 536- 280 2.45 11.19 0.001 2Trn3 46 3Trn 12_ 066274 7 42 46 1 30523 536 536 280 2.45 11.19 0.000 30 7 31 7 2Trn 3 44 1Trn12 860190 7 42 44 1 30523 536 536 260 2.45 11.19 0.000 32 7 27rn 3 43 3Trn11 860148 7 42 43 I 30523 536 536 280 2.45 11.19 0.001 33 3 1Trn2_ 43 3TrolI 206618 3 1 43 1 31236 549 549 257 2.45 12.18 0.005 34 3 1Trn2 19 9T"rn _ 203153 3 1 19 94 23810 549 549 267 2.45 12.18 0.000 35 31 2Trtn 42 2Trnl 1 26255.22 :31 809 42 1 27376 339 339 171 2.45 3.12 0.000 Total, U = 0.411 Overall Fen = 0,32 Notes: 1. T,,- is the maximum temperature of the two paired load states, and represents the metal (nodal) temperature at the location being analyzed. This.

which is included as '" in the'Translent Maximum Temperatures" table above. determined from the VESLFAT output.

2. F_ values computed using the low alloy steel equation from Section 3.0 of Reference [6], with S* conservatively set to a maximuinvalue of 0.015, and tha transformed strain rate conservatively set to a minirmumvalue of In (0.001) =-6.90, for ali load pairs.
3. U_, = [U x HIWCF_ x % HWC) + (Ux NIWCF.,x % NWVC1.
4. T1 and T2 represent the load number for Load #1 and Load #2, respectively, and s l and s2 represent the state number for each of those loads.
5. For each load pair, n- is the number of available cycles for Load #1, n. is the number of available cycles for Load 62. and n Lsthe available number of cycles for the load pair (i.e.. the minimum of n, and nz).

File No.: 0801038.306 Page 18 of 19 Revision: I F0306-01 RO

StructuralIntegrity Associates, Inc.

Table 9: Linearized Stress Files Compiled for VY-RO-StressResults.xls Filename Description VY RONTRAN1-S.csv Transient 1 linearized stress VYRONTRAN2-S.csv Transient 2 linearized stress VY RON TRAN3-S.csv Transient 3 linearized stress VY RON TRAN4-S.csv Transient 4 linearized stress VY RON TRAN5-S.csv Transient 5 linearized stress VY RON TRAN6-S.csv Transient 6 linearized stress VY RONTRAN7-S.csv Transient 7 linearized stress VY RON TRAN8-S.csv Transient 8 linearized stress VY RON TRAN9-S.csv Transient 9 linearized stress VYRON_ TRAN1O-S.csv Transient 10 linearized stress VY RON TRAN11-S.csv Transient 11 linearized stress VY RONTRAN12-S.csv Transient 12 linearized stress Note: All files are from the Reference [1] supporting computer files.

File No.: 0801038.306 Page 19 of 19 Revision: 1 F0306-OIRO

Hearing Docket From: Travieso-Diaz, Matias F. [matias.travieso-diaz@pillsburylaw.com]

Sent: Tuesday, March 10, 2009 3:02 PM To: Alex Karlin; Richard Wardwell; whrcville@embarqmail.com; secy@nrc.gov; Hearing Docket; Susan Uttal; Lloyd Subin; Maxwell Smith; Sarah.hofmann@state.vt.us; aroisman@nationallegalscholars.com; peter.roth@doj.nh.gov; Matthew.Brock@state.ma.us; Zachary Kahn; Mr. Raymond Shadis; OCAAMAIL Resource Cc: Lewis, David R.; Nelson, Blake J.

Subject:

Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No. 50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)

Attachments: Letter to ASLB enclosing revised calculations .pdf In accordance with the provisions of the Board's Partial Initial Decision (Ruling on Contentions 2A, 2B, 3, and 4), LBP-08-25, 68 N.R.C. _ (Nov. 24, 2008), slip op. at 67,.and the Board's Order (Clarifying Deadline for Filing New or Amended Contentions) (Mar. 9, 2009), Entergy has revised and issued its final calculations of record for the confirmatory environmentally assisted fatigue (CUFen) analyses on the reactor pressure vessel core spray (CS) and recirculation outlet (RO) nozzles at the Vermont Yankee Nuclear Power Station. These revised analyses are presented in the following Structural Integrity Associates, Inc. (SIA) calculations: Calculation No.

0801038.302, Revision 1, "Stress Analysis of Reactor Core Spray Nozzle;" Calculation No. 0801038.303, Revision 1, "Fatigue Analysis of Reactor Core Spray Nozzle;"

Calculation No. 0801038.304, Revision 1, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Recirculation Outlet Nozzle;" Calculation No.

0801038.305, Revision 1, "Stress Analysis of Reactor Recirculation Outlet Nozzle;" and Calculation No. 0801038.306, Revision 1, "Fatigue Analysis of Reactor Recirculation Outlet Nozzle." Calculation 0801038.301, Revision 0, "Design Inputs and Methodology for ASME Code Fatigue Usage Analysis of Reactor Core Spray Nozzle" has not been revised so that the version sent to the parties on January 8, 2009 remains the final calculation of record. Entergy is serving at this time electronic copies of those analyses on the parties to the above captioned proceeding.

The methodology applied in the referenced CS and RO confirmatory analyses is in accordance with the approach-used in the SIA calculations for the feedwater nozzle that were introduced into evidence in this proceeding, and contains no significantly different scientific or technical judgments from those used in the feedwater nozzle calculations. See Calculation 0801038.301 at 4, n.1 and Calculation 0801038.304 at 4, n.1.

As set forth in the referenced revised calculations, the limiting calculated CUFenS for the CS and RO nozzles are less than unity and are therefore acceptable.

Hard copies are also being sent today by overnight mail to the NRC Staff, the New England Coalition and the Vermont Department of Public Service.

1

This submittal comprises three electronic messages. This first message, attaching Entergy's cover letter, is being transmitted to the entire service list. The second message, comprising the calculation package for the CS nozzle, is being transmitted only to the parties (including interested States). The third message, comprising the calculation package for the RO nozzle, is being forwarded only to the parties (including interested States).

If you have any difficulty opening this attachment, please contact me at the number below.

Matias F. Travieso-Diaz I Pillsbury Winthrop Shaw Pittman LLP Tel: 202.663.8142 I Fax: 202.663.8007 I Cell: 703.472.6463 2300 "N"Street, NW I Washington, DC 20037-1122 Email: matias.travieso-diaz(cpillsburylaw.com-Bio: www.pillsburylaw.com/matias.travieso-diaz

  • Internal Revenue Service regulations generally provide that, for the purpose of avoiding federal tax penalties, a taxpayer may rely only on formal written advice meeting specific requirements. Any tax advice in this message does not meet those requirements. Accordingly, any such tax advice was not intended or written to be used, and it cannot be used, for the purpose of avoiding federal tax penalties that may be imposed on you or for the purpose of promoting, marketing or recommending to another party any tax-related matters.

2

Received: from mail .nrc.gov (148.184.176.41) by TWMS01 .nrc.gov (148.184.200.145) with Microsoft SMTP Server id 8.1.291.1; Tue, 10 Mar 2009 15:01:59 -0400 X-Ironport-ID: mail1 X-SBRS: 5.3 X-MID: 278153 X-IronPort-Anti-Spam-Filtered: true X-IronPort-Anti-Spam-Result:

AjOCAEVWtknM4/81mWdsb2JhbACCJhMYkIOBAQEBAQg LCgcRrlAJjwiCSxCBMQZh X-IronPort-AV: E=Sophos;i="4.38,337,1233550800";

d="pdf ?scan'208,217";a="278153" Received: from sfmms08.pillsburywinthrop.com (HELO sfemf02.PillsburyWinthrop.com) ([204.227.255.8]) by maill.nrc.gov with ESMTP; 10 Mar 2009 15:01:54 -0400 Received: from [172.17.1.202] by sfemf02.PillsburyWinthrop.com with ESMTP (SFPWSP SMTP Relay (Email Firewall v6.3.2)); Tue, 10 Mar 2009 12:01:38 -0700 X-Server-Uuid: C488EB2B-C670-400C-9182-92FFDA1BD321 Received: from dcxm0l .PillsburyWinthrop.com ([172.16.2.42]) by sfxims0l.PillsburyWinthrop.com with Microsoft SMTPSVC(6.0.3790.3959); Tue, 10 Mar 2009 12:01:37 -0700 X-MimeOLE: Produced By Microsoft Exchange V6.5 Content-Class: urn:content-classes:message Return-Receipt-To: "Travieso-Diaz, Matias F."

<matias.travieso-diaz@pillsburylaw.com>

MIME-Version: 1.0 Disposition-Notification-To: "Travieso-Diaz, Matias F."

<matias.travieso-diaz@pillsburylaw.com>

Subject:

Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No.

50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)

Date: Tue, 10 Mar 2009 15:01:32 -0400 Message-ID:

<91 E8D41 B43905C4BB96FF78D93B1 ED3FO4ED919D@dcxm0l.PillsburyWinthrop.com>

X-MS-Has-Attach:

X-MS-TNEF-Correlator:

Thread-Topic: Entergy Nuclear Vermont Yankee, LLC, and Entergy Nuclear Operations, Inc. (Vermont Yankee Nuclear Power Station), Docket No.

50-271-LR, ASLBP No. No. 06-849-03-LR (Part 1 of 3)

Thread-Index: AcmhsqBNEl E/xb+NRnSr5e7LFNXrig==

From: "Travieso-Diaz, Matias F." <matias.travieso-diaz@pillsburylaw.com>

To: <ask2@nrc.gov>, <rew@nrc.gov>, <whrcville@embarqmail.com>, <secy@nrc.gov>,

<hearingdocket@nrc.gov>, <susan.uttal@nrc.gov>, <Ibs3@nrc.gov>,

<maxwell.smith@nrc.gov>, <Sarah.hofmann@state.vt.us>,

<aroisman@nationallegalscholars.com>, <peter.roth@doj. nh.gov>,

<Matthew. Brock@state.ma.us>, <zachary.kahn@nrc.gov>, "Mr. Raymond Shadis"

<shadis@prexar.com>, <OCAAMAIL@nrc.gov>

CC: "Lewis, David R." <david.lewis@pillsburylaw.com>, "Nelson, Blake J."

<blake.nelson@pillsburylaw.com>

Return-Path: matias.travieso-diaz@pillsburylaw.com X-OriginalArrivalTime: 10 Mar 2009 19:01:37.0810 (UTC)

FILETIME=[A39E9720:01 C9A1 B2]

X-WSS-ID: 65A86698220669178-01-01 Content-Type: multipart/mixed; boundary="----.=NextPart_001_01 C9A1B2.AOA9441 B"