ML11144A085: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 07/08/2011
| issue date = 07/08/2011
| title = Letter to Transmit a Proprietary Audit Report on the Nordic Steam Dryer for Use in the Proposed Extended Power Uprate
| title = Letter to Transmit a Proprietary Audit Report on the Nordic Steam Dryer for Use in the Proposed Extended Power Uprate
| author name = Tam P S
| author name = Tam P
| author affiliation = NRC/NRR/DORL/LPLIII-1
| author affiliation = NRC/NRR/DORL/LPLIII-1
| addressee name = O'Connor T J
| addressee name = O'Connor T
| addressee affiliation = Northern States Power Co
| addressee affiliation = Northern States Power Co
| docket = 05000263
| docket = 05000263
| license number = DPR-022
| license number = DPR-022
| contact person = Tam P S
| contact person = Tam P
| case reference number = TAC MD9990
| case reference number = TAC MD9990
| package number = ML11144A088
| package number = ML11144A088
Line 47: Line 47:
Proprietary audit report cc. (letter only): ListServ Distribution (letter PUBLIC LPL3-1 R/F RidsNrrDorlLpl3-1 Distribution (letter and enclosure):
Proprietary audit report cc. (letter only): ListServ Distribution (letter PUBLIC LPL3-1 R/F RidsNrrDorlLpl3-1 Distribution (letter and enclosure):
CBasavaraju, NRR RidsRgn3MailCenter Resource RidsNrrLABTully Resource RidsAcrsAcnw
CBasavaraju, NRR RidsRgn3MailCenter Resource RidsNrrLABTully Resource RidsAcrsAcnw
_MailCTR Resource RidsNrrPMMonticelio Resource RidsNrrDeEmcb Resource ADAMS Package Accession No.: ML 11144A088 Audit Report Accession No.: ML 11144A096 Letter Accession No.: ML 11144A085 Audit Report Attachment Accession No.: ML 11179A238 ME PTam BTuily anna RPascarelli 7/6/11 7/6/11 7/8/11 *Audit report transmitted by memo of OFFICIAL RECORD}}
_MailCTR Resource RidsNrrPMMonticelio Resource RidsNrrDeEmcb Resource ADAMS Package Accession No.: ML11144A088 Audit Report Accession No.: ML11144A096 Letter Accession No.: ML11144A085 Audit Report Attachment Accession No.: ML11179A238 ME PTam BTuily anna RPascarelli 7/6/11 7/6/11 7/8/11 *Audit report transmitted by memo of OFFICIAL RECORD}}

Revision as of 16:08, 10 July 2019

Letter to Transmit a Proprietary Audit Report on the Nordic Steam Dryer for Use in the Proposed Extended Power Uprate
ML11144A085
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 07/08/2011
From: Tam P
Plant Licensing Branch III
To: O'Connor T
Northern States Power Co
Tam P
Shared Package
ML11144A088 List:
References
TAC MD9990
Download: ML11144A085 (2)


Text

UNITED NUCLEAR REGULATORY WASHINGTON, D.C. 20555*0001 July 8, 2011 Mr. Timothy J. O'Connor Site Vice President Monticello Nuclear Generating Plant Northern States Power Company -Minnesota 2807 West County Road 75 Monticello, MN 55362-9637 MONTICELLO NUCLEAR GENERATING PLANT (MNGP) -AUDIT REPORT, USE OF NORDIC STEAM DRYER FOR EXTENDED POWER UPRATE (TAC NO. MD9990)

Dear Mr. O'Connor:

The Nuclear Regulatory Commission (NRC) staff, with support of contractors, performed an audit of technical information owned by Westinghouse Electric Company and Northern State Power Company (NSPM) to support use of the Nordic Steam Dryer for the proposed extended power uprate, currently under NRC staff review. The audit was held on April 7-8, 2011 at the Rockville, Maryland offices of Westinghouse Electric.

Enclosed please find the NRC staff's audit report. The audit report identifies a total of eighteen (18) action items in Section 4. These action items were discussed during the audit. Please address the action items as identified in the audit report. If your personnel so desire, we would be glad to discuss these action items with them in a teleconference.

Timely resolution of these action items is necessary before the NRC staff can complete its review of the Nordic steam dryer for the proposed extended power uprate. The enclosed audit report will be withheld from public disclosure because the audit was performed on proprietary information.

This transmittal letter, however, is publicly available.

Should you have any questions, please feel free to contact me at (301) 415-1451.

Sincerely, :::-)7 Peter S. Tam, Senior Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-263

Enclosure:

Proprietary audit report cc (letter only): ListServ July 8,2011 Mr. Timothy J. O'Connor Site Vice President Monticello Nuclear Generating Plant Northern States Power Company -Minnesota 2807 West County Road 75 Monticello, MN 55362-9637 MONTICELLO NUCLEAR GENERATING PLANT (MNGP) -AUDIT REPORT, USE OF NORDIC STEAM DRYER FOR EXTENDED POWER UPRATE (TAC NO. MD9990)

Dear Mr. O'Connor:

The Nuclear Regulatory Commission (NRC) staff, with support of contractors, performed an audit of technical information owned by Westinghouse Electric Company and Northern State Power Company (NSPM) to support use of the Nordic Steam Dryer for the proposed extended power uprate, currently under NRC staff review. The audit was held on April 7-8, 2011 at the Rockville, Maryland offices of Westinghouse Electric.

Enclosed please find the NRC staff's audit report. The audit report identifies a total of eighteen (18) action items in Section 4. These action items were discussed during the audit. Please address the action items as identified in the audit report. If your personnel so desire, we would be glad to discuss these action items with them in a teleconference.

Timely resolution of these action items is necessary before the NRC staff can complete its review of the Nordic steam dryer for the proposed extended power uprate. The enclosed audit report will be withheld from public disclosure because the audit was performed on proprietary information.

This transmittal letter, however, is publicly available.

Should you have any questions, please feel free to contact me at (301) 415-1451.

Sincerely, IRA! Peter S. Tam, Senior Project Manager Plant Licensing Branch 1\1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-263

Enclosure:

Proprietary audit report cc. (letter only): ListServ Distribution (letter PUBLIC LPL3-1 R/F RidsNrrDorlLpl3-1 Distribution (letter and enclosure):

CBasavaraju, NRR RidsRgn3MailCenter Resource RidsNrrLABTully Resource RidsAcrsAcnw

_MailCTR Resource RidsNrrPMMonticelio Resource RidsNrrDeEmcb Resource ADAMS Package Accession No.: ML11144A088 Audit Report Accession No.: ML11144A096 Letter Accession No.: ML11144A085 Audit Report Attachment Accession No.: ML11179A238 ME PTam BTuily anna RPascarelli 7/6/11 7/6/11 7/8/11 *Audit report transmitted by memo of OFFICIAL RECORD