{{#Wiki_filter:}} | {{#Wiki_filter:General Directions: This Model SE provides the format and content to be used when preparing the plant-specific SE of an LAR to adopt traveler TSTF-564, Revision 1. The bolded bracketed information shows text that should be filled in for the specific amendment; individual licensees would furnish site-specific nomenclature or values for these bracketed items. The italicized wording provides guidance on what should be included in each section and should not be included in the SE. Federal Register j | ||
Code of Federal RegulationsSafety limits, limiting safety system settings, and limiting control settings | |||
i ii | |||
N N N | |||
{NOTE: If the licensee is in the midst of a fuel transition, all types of fresh and once-burnt fuel should be evaluated to determine which provides the limiting MCPR 95/95, in accordance with the process discussed in traveler TSTF-564, Revision 1.} {NOTE: If a fuel type not included in Table 1 of traveler TSTF-564, Revision 1, is loaded as fresh or once-burnt fuel, the value of the MCPR95/95 reported for that fuel type must be calculated using the mean and standard deviation from a critical power correlation found to be acceptable by the NRC staff. This should be evaluated by the NRC staff in this section of the SE.} {NOTE: The following text is only applicable if the licensee has a core loaded with the fuel(s) referenced in Table 1 of traveler TSTF-564, Revision 1.} | |||
{NOTE: The project manager or reviewer should check the facility's current licensing basis to determine if GDC 10 is applicable or if an equivalent plant-specific design criterion is used. If the facility licensing basis uses a plant-specific design criterion in lieu of GDC 10, the reference to GDC 10 below should be replaced with a reference to the appropriate design criterion from the facility's licensing basis.} NOTEThis section is to be prepared by the PM. As needed, the PM should coordinate with NRR's Environmental Review and NEPA Branch (MENB) to determine the need for an EA. Specific guidance on preparing EAs and considering environmental issues is contained in NRR Office Instruction LIC-203, "Procedural Guidance for Preparing Categorical Exclusions, Environmental Assessments, and Considering Environmental Issues."Federal Register}} | |||
Revision as of 12:59, 11 December 2018
| ML18208A152 | |
| Person / Time | |
|---|---|
| Site: | Technical Specifications Task Force |
| Issue date: | 10/03/2018 |
| From: | NRC/NRR/DSS |
| To: | |
| Honcharik M C, NRR/DSS, 301-415-1774 | |
| Shared Package | |
| ML18207A380 | List: |
| References | |
| CAC MG0161, EPIC L-2017-PMP-0007, TSTF-564, Rev 1 | |
| Download: ML18208A152 (10) | |
Text
General Directions: This Model SE provides the format and content to be used when preparing the plant-specific SE of an LAR to adopt traveler TSTF-564, Revision 1. The bolded bracketed information shows text that should be filled in for the specific amendment; individual licensees would furnish site-specific nomenclature or values for these bracketed items. The italicized wording provides guidance on what should be included in each section and should not be included in the SE. Federal Register j
Code of Federal RegulationsSafety limits, limiting safety system settings, and limiting control settings
i ii
N N N
{NOTE: If the licensee is in the midst of a fuel transition, all types of fresh and once-burnt fuel should be evaluated to determine which provides the limiting MCPR 95/95, in accordance with the process discussed in traveler TSTF-564, Revision 1.} {NOTE: If a fuel type not included in Table 1 of traveler TSTF-564, Revision 1, is loaded as fresh or once-burnt fuel, the value of the MCPR95/95 reported for that fuel type must be calculated using the mean and standard deviation from a critical power correlation found to be acceptable by the NRC staff. This should be evaluated by the NRC staff in this section of the SE.} {NOTE: The following text is only applicable if the licensee has a core loaded with the fuel(s) referenced in Table 1 of traveler TSTF-564, Revision 1.}
{NOTE: The project manager or reviewer should check the facility's current licensing basis to determine if GDC 10 is applicable or if an equivalent plant-specific design criterion is used. If the facility licensing basis uses a plant-specific design criterion in lieu of GDC 10, the reference to GDC 10 below should be replaced with a reference to the appropriate design criterion from the facility's licensing basis.} NOTEThis section is to be prepared by the PM. As needed, the PM should coordinate with NRR's Environmental Review and NEPA Branch (MENB) to determine the need for an EA. Specific guidance on preparing EAs and considering environmental issues is contained in NRR Office Instruction LIC-203, "Procedural Guidance for Preparing Categorical Exclusions, Environmental Assessments, and Considering Environmental Issues."Federal Register