IR 05000315/2009403: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
| Line 3: | Line 3: | ||
| issue date = 06/01/2009 | | issue date = 06/01/2009 | ||
| title = IR 05000315-09-403, IR 05000316-09-403, on 04/27/2009 - 05/01/2009, D. C. Cook Nuclear Power Plant, Units 1 and 2, Routine Security Baseline Inspection - Cover Letter | | title = IR 05000315-09-403, IR 05000316-09-403, on 04/27/2009 - 05/01/2009, D. C. Cook Nuclear Power Plant, Units 1 and 2, Routine Security Baseline Inspection - Cover Letter | ||
| author name = Duncan E | | author name = Duncan E | ||
| author affiliation = NRC/RGN-III/DRS/PSB | | author affiliation = NRC/RGN-III/DRS/PSB | ||
| addressee name = Jensen J | | addressee name = Jensen J | ||
| Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter | {{#Wiki_filter:June 1, 2009 Mr. Joseph Jensen Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 SUBJECT: D. C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 NRC SECURITY BASELINE INSPECTION REPORT 05000315/2009403(DRS); | ||
Mr. Joseph Jensen Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 | |||
SUBJECT: D. C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 NRC SECURITY BASELINE INSPECTION REPORT 05000315/2009403(DRS); | |||
05000316/2009403(DRS) | 05000316/2009403(DRS) | ||
| Line 39: | Line 34: | ||
Should you have any questions concerning this inspection, we will be pleased to discuss them with you. | Should you have any questions concerning this inspection, we will be pleased to discuss them with you. | ||
Sincerely,/RA/ Eric Duncan, Chief Plant Support Branch Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74 Nonpublic | Sincerely, | ||
/RA/ Eric Duncan, Chief Plant Support Branch Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74 Nonpublic Enclosure: Inspection Report 05000315/2009403(DRS); 05000316/2009403(DRS) w/Attachment: Supplemental Information | |||
Inspection Report 05000315/2009403(DRS); 05000316/2009403(DRS) | |||
Supplemental Information | |||
cc w/encl: D. Riffle, NSIR/DSO/DDSO T. Strong, State Liaison Officer cc w/o encl: L. Weber, Site Vice President J. Gebbie, Plant Manager O. Isiogu, Michigan Public Service Commission Michigan Department of Environmental Quality Planning Manager, Emergency Management and Homeland Security Division, Michigan State Police Department | cc w/encl: D. Riffle, NSIR/DSO/DDSO T. Strong, State Liaison Officer cc w/o encl: L. Weber, Site Vice President J. Gebbie, Plant Manager O. Isiogu, Michigan Public Service Commission Michigan Department of Environmental Quality Planning Manager, Emergency Management and Homeland Security Division, Michigan State Police Department | ||
}} | }} | ||
Revision as of 22:01, 11 July 2019
| ML091530502 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 06/01/2009 |
| From: | Eric Duncan Plant Support Branch II |
| To: | Jensen J Indiana Michigan Power Co |
| References | |
| IR-09-403 | |
| Download: ML091530502 (4) | |
Text
June 1, 2009 Mr. Joseph Jensen Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 SUBJECT: D. C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 NRC SECURITY BASELINE INSPECTION REPORT 05000315/2009403(DRS);
Dear Mr. Jensen:
On May 1, 2009, the U. S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at your D. C. Cook Nuclear Power Plant, Units 1 and 2. The inspection covered one or more of the key attributes of the security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on May 1, 2009, with L. Weber and other members of your staff.
The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.
Based on the results of this inspection, no findings of significance were identified. However, one licensee-identified violation, which was determined to be of very low security significance, is listed in this report. The NRC is treating this violation as a non-cited violation (NCV) consistent with Section VI.A.1. of the NRC Enforcement Policy because of the very low security significance of the violation and because it was entered into your corrective action program.
If you contest this NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001; with copies to the Regional Administrator, Region III; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident Inspector at the D. C. Cook Nuclear Power Plant. Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, this transmittal document is decontrolled. In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosures, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response "Security-Related Information - Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390(b)(1).
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
/RA/ Eric Duncan, Chief Plant Support Branch Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74 Nonpublic Enclosure: Inspection Report 05000315/2009403(DRS); 05000316/2009403(DRS) w/Attachment: Supplemental Information
cc w/encl: D. Riffle, NSIR/DSO/DDSO T. Strong, State Liaison Officer cc w/o encl: L. Weber, Site Vice President J. Gebbie, Plant Manager O. Isiogu, Michigan Public Service Commission Michigan Department of Environmental Quality Planning Manager, Emergency Management and Homeland Security Division, Michigan State Police Department