ML103610287: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
| Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:From:Stephen Frantz [sfrantz@me.com]Sent:Friday, December 17, 2010 5:33 PM To:Adams, Alexander | {{#Wiki_filter:From: Stephen Frantz [sfrantz@me.com] | ||
Sent: Friday, December 17, 2010 5:33 PM To: Adams, Alexander | |||
==Subject:== | ==Subject:== | ||
Typo correction Hello Al, There is a typographical error in our most recent License Amendment that I submitted. There is | Typo correction Hello Al, There is a typographical error in our most recent License Amendment that I submitted. There is an ending parenthesis missing. Paragraph 1 under the proposed Tech Spec H should read.... | ||
: 1. All fuel elements or fueled devices shall be rigidly supported during storage in a safe geometry (keff less than 0.8 under all conditions of moderation except for five elements (two with thermocouples, two control rod followers, and one damaged element S/N 4058) being held in an approved NAC-LWT transfer basket. The five elements in the transfer basket shall have a keff less than 0.95.) The edge of the transfer basket shall not be stored within 40 cm of any other fuel elements. | |||
an ending parenthesis missing. Paragraph 1 under the proposed Tech Spec | |||
H should read.... | |||
: 1. All fuel elements or fueled devices shall be rigidly supported during storage in a safe | |||
geometry (keff less than 0.8 under all conditions of moderation except | |||
for five elements (two | |||
with thermocouples, two control rod followers, and one damaged element | |||
S/N 4058) being held | |||
in an approved NAC-LWT transfer basket. The five elements in the | |||
transfer basket shall have a | |||
keff less than 0.95.) The edge of the transfer basket shall not be | |||
stored within 40 cm of any other | |||
fuel elements. | |||
Could you please correct this typographical error on your copy? | Could you please correct this typographical error on your copy? | ||
Thank you. | Thank you. | ||
Stephen-- I only check my email a few times a day. | Stephen | ||
-- | |||
I only check my email a few times a day. | |||
Please phone if it is urgent. | Please phone if it is urgent. | ||
Stephen G. Frantz Reed Research Reactor, Chem-102 | Stephen G. Frantz Reed Research Reactor, Chem-102 3203 SE Woodstock Blvd. | ||
Portland, OR 97202-8199 503-777-7222 f: 503-777-7274 E-mail Properties Mail Envelope Properties (5D56BE9E-F4DA-4792-B358-587B6C0ED0A5) | |||
3203 SE Woodstock Blvd. | |||
Portland, OR 97202-8199 | |||
503-777-7222 f: 503-777-7274 E-mail Properties Mail Envelope Properties (5D56BE9E-F4DA-4792-B358-587B6C0ED0A5) | |||
==Subject:== | ==Subject:== | ||
Typo | Typo correction Sent Date: 12/17/2010 5:33:00 PM Received Date: 12/17/2010 5:33:00 PM From: Stephen Frantz Created By: sfrantz@me.com Recipients: | ||
Alexander.Adams@nrc.gov (Adams, Alexander) | |||
Tracking Status: None | |||
Post Office: | |||
me.com Files Size Date & Time MESSAGE 9198 12/17/2010 Options Expiration Date: | |||
Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received:}} | |||
me. | |||
Priority:olImportanceNormal ReplyRequested:False Return Notification:False Sensitivity: olNormal Recipients received:}} | |||
Revision as of 05:10, 13 November 2019
| ML103610287 | |
| Person / Time | |
|---|---|
| Site: | Reed College |
| Issue date: | 12/17/2010 |
| From: | Frantz S Reed College |
| To: | Alexander Adams Research and Test Reactors Licensing Branch |
| Adams, A 415-1127 | |
| References | |
| TAC ME4086 | |
| Download: ML103610287 (1) | |
Text
From: Stephen Frantz [sfrantz@me.com]
Sent: Friday, December 17, 2010 5:33 PM To: Adams, Alexander
Subject:
Typo correction Hello Al, There is a typographical error in our most recent License Amendment that I submitted. There is an ending parenthesis missing. Paragraph 1 under the proposed Tech Spec H should read....
- 1. All fuel elements or fueled devices shall be rigidly supported during storage in a safe geometry (keff less than 0.8 under all conditions of moderation except for five elements (two with thermocouples, two control rod followers, and one damaged element S/N 4058) being held in an approved NAC-LWT transfer basket. The five elements in the transfer basket shall have a keff less than 0.95.) The edge of the transfer basket shall not be stored within 40 cm of any other fuel elements.
Could you please correct this typographical error on your copy?
Thank you.
Stephen
--
I only check my email a few times a day.
Please phone if it is urgent.
Stephen G. Frantz Reed Research Reactor, Chem-102 3203 SE Woodstock Blvd.
Portland, OR 97202-8199 503-777-7222 f: 503-777-7274 E-mail Properties Mail Envelope Properties (5D56BE9E-F4DA-4792-B358-587B6C0ED0A5)
Subject:
Typo correction Sent Date: 12/17/2010 5:33:00 PM Received Date: 12/17/2010 5:33:00 PM From: Stephen Frantz Created By: sfrantz@me.com Recipients:
Alexander.Adams@nrc.gov (Adams, Alexander)
Tracking Status: None
Post Office:
me.com Files Size Date & Time MESSAGE 9198 12/17/2010 Options Expiration Date:
Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: