| title = Monticello, Enclosure 12 to L-MT-13-029 - WCAP-17252-NP, Revision 3, Acoustic Loads Definition for the Monticello Steam Dryer Replacement Project.
| title = Enclosure 12 to L-MT-13-029 - WCAP-17252-NP, Revision 3, Acoustic Loads Definition for the Monticello Steam Dryer Replacement Project.
| author name = Suddaby D A
| author name = Suddaby D A
| author affiliation = Westinghouse Electric Co, LLC
| author affiliation = Westinghouse Electric Co, LLC

Revision as of 05:19, 4 April 2019

Enclosure 12 to L-MT-13-029 - WCAP-17252-NP, Revision 3, Acoustic Loads Definition for the Monticello Steam Dryer Replacement Project.
ML13092A351
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 03/29/2013
From: Suddaby D A
Westinghouse
To:
Office of Nuclear Reactor Regulation
References
L-MT-13-029, TAC MD9990 WCAP-17252-NP, Rev 3
Download: ML13092A351 (29)


Text

{{#Wiki_filter:L-MT-13-029 ENCLOSURE 12 WESTINGHOUSE WCAP-17252-NP, (NONPROPRIETARY) REVISION 3 ACOUSTIC LOADS DEFINITION FOR THE MONTICELLO STEAM DRYER REPLACEMENT PROJECT 28 pages follow Westinghouse Non-Proprietary Class 3 WCAP-17252-NP March 2013 Revision 3 Acoustic Loads Definition for the Monticello Steam Dryer Replacement Project Westinghouse WESTINGHOUSE NON-PROPRIETARY CLASS 3 WCAP-17252-NP Revision 3 Acoustic Loads Definition for the Monticello Steam Dryer Replacement Project Author: David A. Suddaby Acoustics & Structural Analysis Reviewer: Gianluca Longoni Acoustics & Structural Analysis March 2013 Approved: David R. Forsyth*, Manager Acoustics & Structural Analysis*Electronically approved records are authenticated in the electronic document management system.Westinghouse Electric Company LLC 1000 Westinghouse Drive Cranberry Township, PA 16066© 2013 Westinghouse Electric Company LLC All Rights Reserved WCAP- I 7252-NP.doc-031213 iv RECORD OF REVISIONS Revision Author Description Date 0 Gianluca Longoni Load Definition Based on ACM Rev. 4.0 June 16, 2010 1 Not Used 2 Gianluca Longoni Load Definition Based on ACE Rev. 1.0 May 25, 2012 3 David A. Suddaby Load Definition Based on ACE Rev. 2.0 See EDMS WCAP- 17252-NP March 2013 Revision 3 V TABLE OF CONTENTS LIST OF TAB LES ....................................................................................................................................... vi LIST OF FIG U RES .................................................................................................................................... vii A CRON YM S ............................................................................................................................................. viii I EX ECUTIVE SUM M A RY ........................................................................................................... 1-I 2 [ ]a ............................... 2-1 2.1 INTRO DUCTION ...................................................................................................... 2-1 2.2 [] ............................................. 2-2 2.3 [................................................................................................................... 2-5 3 1........................................................................................ 3-3.1 INTRO D UCTION ........................................................................................................... 3-1 3.2 [ ] ..................................... 3-2 3.3 ]a ........................................................................ 3-2 4 [ ] 4....4-1 5 RE FEREN CES ............................................................................................................................. 5-1 WCAP-17252-NP March 2013 Revision 3 vi Table 3-1 Table 3-2 Table 3-3 Table 3-4 Table 4-1[[[[[LIST OF TABLES] b, b.c ................................................................................. 3-2]a. .............................................................. 3-3]a ................................................ 3-3]a .................................................................... .3-3]a ................................................ 4 -1 WCAP-17252-NP March 2013 Revision 3 vii LIST OF FIGURES Figure 2-1 Figure 2-2 Figure 2-3 Figure 2-4 Figure 2-5 Figure 2-6 Figure 3-1 Figure 4-1 [Figure 4-2 [Figure 4-3 [Figure 4-4 [Figure 4-5 Figure 4-6]r .................................................................... 2-2]a ..................................................................... 2 -3]r ....................................................................... 2-4]a ............................................................................. 2 -4......................................................................... 2 -5 P ..................................................................... 2 -9........................................................................................... 3 -1]P ................................... 4-2]a ................................. 4-3]a ............................. 4-4]a ................................... 4-5 la]s ....................... 4-6]a ......................... 4-7 WCAP- 17252-NP March 2013 Revision 3 viii ACRONYMS 3-D ACE CLTP EPU FEM MSL PSD RMS SNR SRV three-dimensional acoustic circuit enhanced current licensed thermal power extended power uprate finite element model main steam line power spectral density root mean square signal-to-noise ratio safety relief valve WCAP- 17252-NP March 2013 Revision 3 1-1 1 EXECUTIVE

SUMMARY

[]a II]a IIIn conclusion, based on a detailed pressure load definition obtained using]a it was determined that [ia,b,c II]a WCAP-I 7252-NP March 2013 WCAP- 17252-NP March 2013 Revision 3 2-1 2 [

2.1 INTRODUCTION

[I a pabc WCAP- 17252-NP March 2013 Revision 3 2-2 2.2 I a I Ia a Figure 2-1 []a II] a, c WCAP- 17252-NP March 2013 Revision 3 2-3 a, b Figure 2-2 1 la[]a.b WCAP- 17252-NP March 2013 Revision 3 2-4 a Figure 2-3 1 Figure 2-4 1]a I la WCAP- 17252-NP March 2013 Revision 3 2-5 2.3 1 I a I]a I II Ia[[a] a a a Figure 2-5 1]a WCAP- 17252-NP March 2013 Revision 3 2-6 a]II a Kaa a WCAP- 17252-NP March 2013 Revision 3 2-7 a-i Ia I]L[a la K K Sa]at I a I WCAP- 1 7252-NP a March 2013 Revision 3 2-8 ja a WCAP-17252-NP March 2013 Revision 3 2-9 a, b Figure 2-6 1 ia II II pa b Sac WCAP- 17252-NP March 2013 Revision 3 3-1 3 I a

3.1 INTRODUCTION

II]a* [* []a]a II]a a Figure 3-1 [ia II WCAP- 17252-NP March 2013 Revision 3 3-2 3.2 [ ]a]a Table 3-1 ]2, b. c a, b, c 3.3 1 ]a WCAP- 17252-NP March 2013 Revision 3 3-3 Table 3-2 1 ja a, b, c a, b, c I I Table 3-4 1 In._______________ a, b, c WCAP- 17252-NP March 2013 Revision 3 4-1 a Table 4-1 b ,a bc WCAP- 17252-NP March 2013 Revision 3 4-2-1 a,b, c Figure 4-1 1 l a WCAP- 17252-NP March 2013 Revision 3 4-3 a,bc Figure 4-2 1]a WCAP- 17252-NP March 2013 Revision 3 4-4 a~b,c Figure 4-3 1 1~WCAP-17252-NP March 2013 Revision 3 4-5 a,b,c Figure 4-4 []a WCAP- 17252-NP March 2013 Revision 3 4-6 a, b Figure 4-5 1 I a,C WCAP- 17252-NP March 2013 Revision 3 4-7 a, b Figure 4-6 [ia WCAP- 17252-NP March 2013 Revision 3 5-1 5 REFERENCES

1. [IC 2. [I C WCAP- 17252-NP March 2013 Revision 3}}