ML16337A008: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 1: Line 1:
{{Adams
#REDIRECT [[SBK-L-16165, 2016/12/01 NRR E-mail Capture - Need for Supplement to ILRT License Amendment Seabrook Station, License Amendment Request 16-01, Request to Extend Containment Leakage Test Frequency]]
| number = ML16337A008
| issue date = 12/01/2016
| title = 2016/12/01 NRR E-mail Capture - Need for Supplement to ILRT License Amendment Seabrook Station, License Amendment Request 16-01, Request to Extend Containment Leakage Test Frequency
| author name = Poole J C
| author affiliation = NRC/NRR/DORL/LPLI-2
| addressee name = Browne K
| addressee affiliation = Nextera Energy
| docket = 05000443
| license number = NPF-086
| contact person =
| case reference number = SBK-L-16165
| document type = E-Mail, Request for Additional Information (RAI)
| page count = 2
}}
 
=Text=
{{#Wiki_filter:1 NRR-PMDAPEm Resource From: Poole, Justin Sent: Thursday, December 01, 2016 3:30 PM To:'Browne, Kenneth' Cc:'Thomas, Christine'
 
==Subject:==
Need for Supplement to IL RT license amendment Ken, On October 27, 2016, NextEra provided responses to t he NRC staff's request for additional information (RAI) related to the license amendment request regarding extending containment leakage testing frequency. On November 28, we held a call with your staff to clarify the response to EMCB-RAI-2. As discussed during the call, the NRC staff would like you to clarify the fo llowing on the docket in a supplemental response. 
 
EMCB-RAI-2:
 
The last sentence of the response to EMCB-RAI-2 states, "since the corrosion allowance for the base mat is less than the cylindrical liner plate, the corrosion analysis is bounded by the base mat analysis and further justified in the response to EMCB RAI-3." Earlier in the response the licensee states the corrosion allowance for the cylinder is 0.094" in general with a 0.1875" allowance for localized areas and the allowance for the base mat area is 0.125."
It is not clear the quoted statement is accurate unless the licensee is referring to the localized corrosion allowance for the cylinder. The licensee should clarify the statement and if the localized allowance is being used a technical justification should be provided for use of the localized allowance instead of the general allowance.
Thanks. Justin C. Poole Project Manager NRR/DORL/LPLI-2 U.S. Nuclear Regulatory Commission (301)415-2048
 
Hearing Identifier:  NRR_PMDA Email Number:  3194  Mail Envelope Properties  (d32077e05e30428fbc34853240f1998a) 
 
==Subject:==
Need for Supplement to ILRT license amendment  Sent Date:  12/1/2016 3:30:22 PM  Received Date:  12/1/2016 3:30:22 PM From:    Poole, Justin Created By:  Justin.Poole@nrc.gov Recipients:    "'Thomas, Christine'" <Christine.Thomas@nexteraenergy.com>
Tracking Status: None  "'Browne, Kenneth'" <Kenneth.J.Browne@nexteraenergy.com>  Tracking Status: None Post Office:  HQPWMSMRS01.nrc.gov 
 
Files    Size      Date & Time MESSAGE    1374      12/1/2016 3:30:22 PM 
 
Options  Priority:    Standard  Return Notification:    No  Reply Requested:    No  Sensitivity:    Normal  Expiration Date:      Recipients Received:}}

Revision as of 00:24, 5 February 2019