River Bend Electrical RAI clarification phone call - questions Albert and Manny, After reviewing the RAI response, I have the following questions: ~      The response refers to an EPRI aging study for polymeric high voltage insulators. I wasunable to find this. Does the applicant have a report number?~      Is there another industry reference, document, handbook, or study regarding polymeric highvoltage insulators that the applicant reviewed to arrive at their justifications for not havingan aging management program?~      Has the applicant considered some of the recent industry events regarding mechanical wear,corrosion and separation of the metallic parts of the high voltage insulators?~      What is the site-specific preventive maintenance procedure that monitors potential buildupof deposits on the surfaces of new polymeric high voltage insulators?  The site has hadcooling tower plume chemical deposit issues on porcelain insulators in the past. Thanks, Mo SadollahNRR/DE/EENBO9G11(301) 415-6804
River Bend Electrical RAI clarification phone call - questions Albert and Manny, After reviewing the RAI response, I have the following questions: ~      The response refers to an EPRI aging study for polymeric high voltage insulators. I wasunable to find this. Does the applicant have a report number?~      Is there another industry reference, document, handbook, or study regarding polymeric highvoltage insulators that the applicant reviewed to arrive at their justifications for not havingan aging management program?~      Has the applicant considered some of the recent industry events regarding mechanical wear,corrosion and separation of the metallic parts of the high voltage insulators?~      What is the site-specific preventive maintenance procedure that monitors potential buildupof deposits on the surfaces of new polymeric high voltage insulators?  The site has hadcooling tower plume chemical deposit issues on porcelain insulators in the past. Thanks, Mo SadollahNRR/DE/EENBO9G11(301) 415-6804}}
}}

Revision as of 22:15, 17 May 2018

River Bend Electrical RAI Clarification Phone Call - Questions
ML18072A062
Person / Time
Site: River Bend Entergy icon.png
Issue date: 03/12/2018
From: Wong A
NRC/NRR/DMLR/MRPB
To: Breonna Compton
Division of Operating Reactor Licensing
Albert Wong, NRR/DMLR/MRPB, 415-3081
References
Download: ML18072A062 (1)


Text

From:Wong, AlbertTo:Compton, BreonnaCc:Sayoc, Emmanuel

Subject:

Please enter this e-mail into ADAMS ASAP - FW: River Bend Electrical RAI clarification phone call - questionsDate:Tuesday, March 13, 2018 9:27:22 AMWe need the ADAMS # so Manny can post it on the PMNS. The call with RBS is this afternoon. I willbring you a 665. Thank you very much, aw From: Sadollah, Mohammad Sent: Monday, March 12, 2018 6:02 PMTo: Wong, Albert <Albert.Wong@nrc.gov>; Sayoc, Emmanuel <Emmanuel.Sayoc@nrc.gov>Cc: Nguyen, Duc <Duc.Nguyen@nrc.gov>; Martinez Navedo, Tania<Tania.MartinezNavedo@nrc.gov>; Otto, Ngola <Ngola.Otto@nrc.gov>

Subject:

River Bend Electrical RAI clarification phone call - questions Albert and Manny, After reviewing the RAI response, I have the following questions: ~ The response refers to an EPRI aging study for polymeric high voltage insulators. I wasunable to find this. Does the applicant have a report number?~ Is there another industry reference, document, handbook, or study regarding polymeric highvoltage insulators that the applicant reviewed to arrive at their justifications for not havingan aging management program?~ Has the applicant considered some of the recent industry events regarding mechanical wear,corrosion and separation of the metallic parts of the high voltage insulators?~ What is the site-specific preventive maintenance procedure that monitors potential buildupof deposits on the surfaces of new polymeric high voltage insulators? The site has hadcooling tower plume chemical deposit issues on porcelain insulators in the past. Thanks, Mo SadollahNRR/DE/EENBO9G11(301) 415-6804