{{#Wiki_filter:Exelon Generation Company, LLC Braidwood Station 35100 South Route 53, Suite 84 Braceville, IL 60407-9619 www.exeloncorp.com January 31, 2022 BW220011 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Braidwood Station, Unit 2 Renewed Facility Operating License No. NPF-77 NRC Docket No. STN 50-457 | {{#Wiki_filter:Exelon Generation Company, LLC Braidwood Station 35100 South Route 53, Suite 84 Braceville, IL 60407-9619 | ||
www.exeloncorp.com | |||
January 31, 2022 BW220011 | |||
U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 | |||
Braidwood Station, Unit 2 Renewed Facility Operating License No. NPF-77 NRC Docket No. STN 50-457 | |||
==Subject:== | ==Subject:== | ||
Braidwood Station, Unit 2 Inservice Inspection Summary Report Enclosed please find the post-outage summary report for Inservice Inspection (lSI) examinations conducted prior to and | Braidwood Station, Unit 2 Inservice Inspection Summary Report | ||
Please direct any questions you may have regarding | |||
Enclosed please find the post-outage summary report for Inservice Inspection (lSI) examinations conducted prior to and d uring Braidwood Station, Unit 2 Refueling Outage 2 2 (A2R22). This report is submitted in accordance with the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI, "Rules for the Inservice Inspection of Nuclear Power Plant Components," and ASME Code Case N-532-5, "Repair/Replacement Activity Documentation Requirements and Inservice Inspection Summary Report Preparation and Submission - Section XI, Division 1." | |||
provides the Owner's Activity Report (OAR) for lSI activities conducted prior to and during A2R22 including a list of items with flaws or relevant conditions that required evaluation for continued service, and an abstract of repair/replacement activities required for continued service. | |||
: 1. Owner's Activity Report (OAR) for | Please direct any questions you may have regarding t his submittal to Mr. Richard Schliessmann, acting Regulatory Assurance Manager, at (815) 417-2820. | ||
John P Keenan Site Vice President Braidwood Station | |||
Attachments: | |||
: 1. Owner's Activity Report (OAR) for r e f u e l i n g o u t a g e A2R22 | |||
cc: Regional Administrator - NRC Region III NRC Senior Resident Inspector - Braidwood Station NRR Project Manager - Braidwood Station Illinois Emergency Management Agency - Division of Nuclear Safety}} | |||
Revision as of 19:04, 18 November 2024
| ML22031A043 | |
| Person / Time | |
|---|---|
| Site: | Braidwood |
| Issue date: | 01/31/2022 |
| From: | Keenan J Exelon Generation Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML22031A042 | List: |
| References | |
| BW220011 | |
| Download: ML22031A043 (1) | |
Text
Exelon Generation Company, LLC Braidwood Station 35100 South Route 53, Suite 84 Braceville, IL 60407-9619
www.exeloncorp.com
January 31, 2022 BW220011
U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Braidwood Station, Unit 2 Renewed Facility Operating License No. NPF-77 NRC Docket No. STN 50-457
Subject:
Braidwood Station, Unit 2 Inservice Inspection Summary Report
Enclosed please find the post-outage summary report for Inservice Inspection (lSI) examinations conducted prior to and d uring Braidwood Station, Unit 2 Refueling Outage 2 2 (A2R22). This report is submitted in accordance with the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, "Rules for the Inservice Inspection of Nuclear Power Plant Components," and ASME Code Case N-532-5, "Repair/Replacement Activity Documentation Requirements and Inservice Inspection Summary Report Preparation and Submission - Section XI, Division 1."
provides the Owner's Activity Report (OAR) for lSI activities conducted prior to and during A2R22 including a list of items with flaws or relevant conditions that required evaluation for continued service, and an abstract of repair/replacement activities required for continued service.
Please direct any questions you may have regarding t his submittal to Mr. Richard Schliessmann, acting Regulatory Assurance Manager, at (815) 417-2820.
John P Keenan Site Vice President Braidwood Station
Attachments:
- 1. Owner's Activity Report (OAR) for r e f u e l i n g o u t a g e A2R22
cc: Regional Administrator - NRC Region III NRC Senior Resident Inspector - Braidwood Station NRR Project Manager - Braidwood Station Illinois Emergency Management Agency - Division of Nuclear Safety