NUREG-1604, Discusses GL 95-03, Circumferential Cracking of SG Tubes, Issues on 950428.Staff Findings Re Issue of GL Contained in NUREG-1604: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot change) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 19: | Line 19: | ||
=Text= | =Text= | ||
{{#Wiki_filter:, | {{#Wiki_filter:,_ | ||
C-V4] | C-V4] | ||
p uog g | |||
i UNITED STATES g | |||
j NUCLEAR REGULATORY COMMISSION I t WASHINoToN. D.C. 2056t@001 k.....,/ | |||
August 7, 1997 Mr. Ted C. Feigenbaum Executive Vice President and Chief Nuclear Officer North Atlantic Energy Service Corporation c/o Mr. Terry L. Harpster P.O. Box 300 Seabrook, NH 03874 | |||
==SUBJECT:== | ==SUBJECT:== | ||
| Line 28: | Line 30: | ||
==Dear Mr. Feigenbaum:== | ==Dear Mr. Feigenbaum:== | ||
On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, "Circamferential Cracking of Steam Generator Tubes," to all holders of operating licenses or construction permits for pressurized-water reactors. The NRC issued GL 95-03 for three principal reasons: | |||
On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, "Circamferential Cracking of Steam Generator Tubes," to all holders of operating licenses or construction permits for pressurized-water reactors. The NRC issued GL 95-03 for three principal reasons: | i (1) | ||
Notify addressees about the safety significance of the w.ent steam generator tube inspection findings at Maine Yankee Atomic Power Station, (2) | |||
Request that all addressees implement the actions described within the generic letter, and (3) | |||
Require that all addressees submit to the hRC a written response regarding implementation of the requested actions. | |||
In addition, GL 95-03 alerted addressees to the importance of performing comprehensive examinations of steam generator tubes using techniques and equipment capable of reliably detecting the types of degradation to which the steam generator tubes could be susceptible. The staff also noted that the performance of steam generator tube examinations is controlled, in part, by Appendix B to Title 10 Part 50, of the Code of federal Regularfons (10 CFR Part 50). | In addition, GL 95-03 alerted addressees to the importance of performing comprehensive examinations of steam generator tubes using techniques and equipment capable of reliably detecting the types of degradation to which the steam generator tubes could be susceptible. The staff also noted that the performance of steam generator tube examinations is controlled, in part, by Appendix B to Title 10 Part 50, of the Code of federal Regularfons (10 CFR Part 50). | ||
In GL 95-03, the NRC staff tb o requested that licensees take the following actions: | In GL 95-03, the NRC staff tb o requested that licensees take the following actions: | ||
(1) | (1) | ||
Evaluate recent operating experience with respect to the detection and 4 | |||
sizing of circumferential indications to determine the applicability to gl" their plants, (2) | |||
On the basis of the evaluation in Item (1) above, as well as past 0 | |||
inspection scope and results, susceptibility to circumferential I | |||
cracking, threshold of detection, expected or inferred crack growth rates, and other relevant factors, develop a saie g assessment justifying continued operation until the next scheduled steam generator tube inspections, 9708130355 970807 PDR ADOCK 05000443 RBC ME CENTER COPY lillillIquilJIUllllilli | |||
North Atlantic Energy Service Corporation | North Atlantic Energy Service Corporation Seabrook Station, Unit No. I cc* | ||
Lillian M. Cuoco. Esq. | Lillian M. Cuoco. Esq. | ||
Northeast Utilities Service Company | Mr. Dan McElhinney Senior Nuclear Counsel Federal Emergency Management Agency. | ||
Hartford, CT 06141-0270 | Northeast Utilities Service Company Region I P.O. Box 270 J.W. McCormack P.O. & | ||
Hartford, CT 06141-0270 Courthouse Building, Room 401 i | |||
P,0. Box 300 Town of Amesbury | Boston, MA 02109 Mr. Peter Brann Assistant Attorney General Mr. Peter LaPorte, Director State House, Station #6 ATTN: James Muckerheide | ||
-Augusta, ME 04333 Massachusetts Emergency Management Agency Resident Inspector 400 Worcester Road l | |||
U.S. Nuclear Regulatory Comission P.O. Box 1496 l | |||
Seabrook Nuclear Power Station Framingham, MA 01701-0317 P.O. Box 1149 Seabrook, NH 03874 Jeffrey Howard, Attorney General Jane Spector G. Dana Bisbee, Deputy Attorney General Federal Energy Regulatory Commission 33 Capitol Street 825 North Capital Street, N.E. | |||
Concord, NH 03301 Room B105 Washington, DC 20426 Mr. D. M. Goebel Town of Exeter Vice President-Nuclear Oversight 10 Front Street Northeast Utilities Service C'ampany P. O. Box 270 Exeter, NH 03823 Hartford, CT 06141-0270 Mr. George L. Iverson, Director Mr. J. K. Thayer New Hampshire Office of Emergency Recovery Officer, Nuclear Engineering Management and Support State Office Park South 197 Pleasant Street Northeast Utilities Service Company P.O. Box 128 Concord, NH 03301 Waterford, CT 06385 Regional Administrator, Region I Mr. f. C. Rothen U.S. Nuclear Regulatory Comission Vice President - Nuclear Work Services 475 Allendale Road Northeast Utilities Service Company King of Prussia, PA 19406 P.O. Box 128 Waterford, CT 06385 Office of the Attorney General One Ashburton P! ace 20th Floor Mr. A. M. Callendrello Boston, MA 02108 Licensing Manager - Seabrook Station Board of Selectmen North Atlantic Energy Service Corp. | |||
P,0. Box 300 Town of Amesbury Seabrook, NH 03874 Town Hall Amesbury, MA 01913 | |||
.... =.... | |||
F__ _ _ _- | |||
F__ | ~ | ||
\\ | |||
North Atlantic Energy Service Corporation | North Atlantic Energy Service Corporation Seabrook Station, Unit No. I cc: | ||
Mr. W. A. DiProfio~ | Mr. W. A. DiProfio~ | ||
Nuclear Unit Directcr Seabrook Station Morth Atlantic Eneriy Service Corporatic;i P.O. Box 300 Seabrook, NH 03874 Mr. Frank W. Getman, Jr. | Nuclear Unit Directcr Seabrook Station Morth Atlantic Eneriy Service Corporatic;i P.O. Box 300 Seabrook, NH 03874 Mr. Frank W. Getman, Jr. | ||
| Line 52: | Line 67: | ||
Seabrook, NH 03874 l | Seabrook, NH 03874 l | ||
Mr. Ted C..Feigenbaum | Mr. Ted C..Feigenbaum 1 (3) | ||
Develop plans for the next-steam generator tube inspections as they pertain to the detection of circumferential cracking. The inspection plans should address, but not be limited to, scope (including sample expansion criteria, if applicable), methods, equipment, and criteria (including personnel training and qualification). | |||
To document the outcome of these actions, the NRC staff requested that addressees prepare and submit: | To document the outcome of these actions, the NRC staff requested that addressees prepare and submit: | ||
-(1). | |||
A safety assessment justifying continued operation, predicated on the evaluation performed in accordance with requested actions 1 and 2 (above),and (2) | |||
A summary of the inspection plans developed in accordance with requested action 3 (above) and a schedule for the next planned inspection. | |||
Mr. John Opeka's {{letter dated|date=June 27, 1995|text=letter dated June 27, 1995}}, and your {{letter dated|date=October 23, 1995|text=letter dated October 23, 1995}}, provided the information requested by GL 95-03, and therefore TAC No. | Mr. John Opeka's {{letter dated|date=June 27, 1995|text=letter dated June 27, 1995}}, and your {{letter dated|date=October 23, 1995|text=letter dated October 23, 1995}}, provided the information requested by GL 95-03, and therefore TAC No. | ||
M92273 is closed. For your information, the staff's findings regarding this issue are contained in NUREG-1604, "Circumferential Cracking of Steam-Generator Tubes." | M92273 is closed. | ||
t l | For your information, the staff's findings regarding this issue are contained in NUREG-1604, "Circumferential Cracking of Steam-Generator Tubes." | ||
t l | |||
DATE- | Sincerely, Original signed by Albert W. De Agazio, Sr. Project Manager Project Directorate.I-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No. 50-443 DISTRIBUTION A. Deagazio Serial No. SEA-97-019 Docket File ACRS PUBLIC C. Hehl cc: | ||
See next page PDI-3 RF K. Karwoski B. Boger R. Eaton S. Dembek S. Little OGC DOCUMENT NAME: G:\\DEAGAZIO\\92273LET To receive a copy of this document, imlicate in'the box: | |||
"C" - Copy without | |||
, attachment / enclosure "E" = Copy with attachment /enclosurg / "N" - No copy 0FFICE P91 3/ptl | |||
,w g j | |||
[ | |||
P0ll 3/LA_t Q | |||
[ | |||
( A)0@3/ - | |||
l l | |||
NAME Seegazio /)XV Slittle # | |||
REstm)' | |||
DATE-OS/ 7/97 //F 08/ b /97 08/s)/97 0FFICIAL RECORD COPY | |||
_ - _ _ _ - _ - - _ _}} | _ - _ _ _ - _ - - _ _}} | ||
Revision as of 08:29, 3 December 2024
| ML20217H949 | |
| Person / Time | |
|---|---|
| Site: | Seabrook |
| Issue date: | 08/07/1997 |
| From: | Agazio A NRC (Affiliation Not Assigned) |
| To: | Feigenbaum T, Harpster T NORTH ATLANTIC ENERGY SERVICE CORP. (NAESCO) |
| References | |
| RTR-NUREG-1604 GL-95-03, GL-95-3, TAC-M92273, NUDOCS 9708130355 | |
| Download: ML20217H949 (4) | |
Text
,_
C-V4]
p uog g
i UNITED STATES g
j NUCLEAR REGULATORY COMMISSION I t WASHINoToN. D.C. 2056t@001 k.....,/
August 7, 1997 Mr. Ted C. Feigenbaum Executive Vice President and Chief Nuclear Officer North Atlantic Energy Service Corporation c/o Mr. Terry L. Harpster P.O. Box 300 Seabrook, NH 03874
SUBJECT:
GENERIC LETTER 95-03, "CIRCUMFERENTIAL CRACKING OF STEAM GENERATOR TUBES," COMPLETION OF LICENSING ACTION (TAC NO. M92273)
Dear Mr. Feigenbaum:
On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, "Circamferential Cracking of Steam Generator Tubes," to all holders of operating licenses or construction permits for pressurized-water reactors. The NRC issued GL 95-03 for three principal reasons:
i (1)
Notify addressees about the safety significance of the w.ent steam generator tube inspection findings at Maine Yankee Atomic Power Station, (2)
Request that all addressees implement the actions described within the generic letter, and (3)
Require that all addressees submit to the hRC a written response regarding implementation of the requested actions.
In addition, GL 95-03 alerted addressees to the importance of performing comprehensive examinations of steam generator tubes using techniques and equipment capable of reliably detecting the types of degradation to which the steam generator tubes could be susceptible. The staff also noted that the performance of steam generator tube examinations is controlled, in part, by Appendix B to Title 10 Part 50, of the Code of federal Regularfons (10 CFR Part 50).
In GL 95-03, the NRC staff tb o requested that licensees take the following actions:
(1)
Evaluate recent operating experience with respect to the detection and 4
sizing of circumferential indications to determine the applicability to gl" their plants, (2)
On the basis of the evaluation in Item (1) above, as well as past 0
inspection scope and results, susceptibility to circumferential I
cracking, threshold of detection, expected or inferred crack growth rates, and other relevant factors, develop a saie g assessment justifying continued operation until the next scheduled steam generator tube inspections, 9708130355 970807 PDR ADOCK 05000443 RBC ME CENTER COPY lillillIquilJIUllllilli
North Atlantic Energy Service Corporation Seabrook Station, Unit No. I cc*
Lillian M. Cuoco. Esq.
Mr. Dan McElhinney Senior Nuclear Counsel Federal Emergency Management Agency.
Northeast Utilities Service Company Region I P.O. Box 270 J.W. McCormack P.O. &
Hartford, CT 06141-0270 Courthouse Building, Room 401 i
Boston, MA 02109 Mr. Peter Brann Assistant Attorney General Mr. Peter LaPorte, Director State House, Station #6 ATTN: James Muckerheide
-Augusta, ME 04333 Massachusetts Emergency Management Agency Resident Inspector 400 Worcester Road l
U.S. Nuclear Regulatory Comission P.O. Box 1496 l
Seabrook Nuclear Power Station Framingham, MA 01701-0317 P.O. Box 1149 Seabrook, NH 03874 Jeffrey Howard, Attorney General Jane Spector G. Dana Bisbee, Deputy Attorney General Federal Energy Regulatory Commission 33 Capitol Street 825 North Capital Street, N.E.
Concord, NH 03301 Room B105 Washington, DC 20426 Mr. D. M. Goebel Town of Exeter Vice President-Nuclear Oversight 10 Front Street Northeast Utilities Service C'ampany P. O. Box 270 Exeter, NH 03823 Hartford, CT 06141-0270 Mr. George L. Iverson, Director Mr. J. K. Thayer New Hampshire Office of Emergency Recovery Officer, Nuclear Engineering Management and Support State Office Park South 197 Pleasant Street Northeast Utilities Service Company P.O. Box 128 Concord, NH 03301 Waterford, CT 06385 Regional Administrator, Region I Mr. f. C. Rothen U.S. Nuclear Regulatory Comission Vice President - Nuclear Work Services 475 Allendale Road Northeast Utilities Service Company King of Prussia, PA 19406 P.O. Box 128 Waterford, CT 06385 Office of the Attorney General One Ashburton P! ace 20th Floor Mr. A. M. Callendrello Boston, MA 02108 Licensing Manager - Seabrook Station Board of Selectmen North Atlantic Energy Service Corp.
P,0. Box 300 Town of Amesbury Seabrook, NH 03874 Town Hall Amesbury, MA 01913
.... =....
F__ _ _ _-
~
\\
North Atlantic Energy Service Corporation Seabrook Station, Unit No. I cc:
Mr. W. A. DiProfio~
Nuclear Unit Directcr Seabrook Station Morth Atlantic Eneriy Service Corporatic;i P.O. Box 300 Seabrook, NH 03874 Mr. Frank W. Getman, Jr.
Cocheco Falls Millworks 100 Main Street, Suite 201 Dover, NH 03820 Mr. B. D. Kenyon President - Nuclear Group Northeast Utilities Service Group P.O. Box 128 Waterford, CT 06385 Mr. B. L. Drawbridge Executive Director Services &
Senior Site Officer North Atlantic Energy Service Corp.
Seabrook, NH 03874 l
Mr. Ted C..Feigenbaum 1 (3)
Develop plans for the next-steam generator tube inspections as they pertain to the detection of circumferential cracking. The inspection plans should address, but not be limited to, scope (including sample expansion criteria, if applicable), methods, equipment, and criteria (including personnel training and qualification).
To document the outcome of these actions, the NRC staff requested that addressees prepare and submit:
-(1).
A safety assessment justifying continued operation, predicated on the evaluation performed in accordance with requested actions 1 and 2 (above),and (2)
A summary of the inspection plans developed in accordance with requested action 3 (above) and a schedule for the next planned inspection.
Mr. John Opeka's letter dated June 27, 1995, and your letter dated October 23, 1995, provided the information requested by GL 95-03, and therefore TAC No.
M92273 is closed.
For your information, the staff's findings regarding this issue are contained in NUREG-1604, "Circumferential Cracking of Steam-Generator Tubes."
t l
Sincerely, Original signed by Albert W. De Agazio, Sr. Project Manager Project Directorate.I-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No. 50-443 DISTRIBUTION A. Deagazio Serial No. SEA-97-019 Docket File ACRS PUBLIC C. Hehl cc:
See next page PDI-3 RF K. Karwoski B. Boger R. Eaton S. Dembek S. Little OGC DOCUMENT NAME: G:\\DEAGAZIO\\92273LET To receive a copy of this document, imlicate in'the box:
"C" - Copy without
, attachment / enclosure "E" = Copy with attachment /enclosurg / "N" - No copy 0FFICE P91 3/ptl
,w g j
[
P0ll 3/LA_t Q
[
( A)0@3/ -
l l
NAME Seegazio /)XV Slittle #
REstm)'
DATE-OS/ 7/97 //F 08/ b /97 08/s)/97 0FFICIAL RECORD COPY