IR 05000254/1998024: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot change)
(StriderTol Bot change)
Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:.. - . . ..- - .- ._  - - _ _-
{{#Wiki_filter:March 10, 1999
        --_
 
*
==SUBJECT:==
. .
NRC QUAD CITIES SECURITY INSPECTION REPORTS 50-254/98024(DRS);
,
50-265/98024(DRS)
k March 10, 1999 Mr. Oliver President, Nuclear Generation Group    i Commonwealth Edison Company      I l  ATTN: Regulatory Services l  Executive Towers West lli l  1400 Opus Place, Suite 500 Downers Grove,IL 60515      '
!
SUBJECT: NRC QUAD CITIES SECURITY INSPECTION REPORTS 50-254/98024(DRS);
50-265/98024(DRS)


==Dear Mr. Kingsley:==
==Dear Mr. Kingsley:==
This acknowledges receipt of a letter dated February 12,1999, signed by Mr. Joel Dimmette, Jr. of your staff which clarified the corrective action for the violation identified in NRC Quad Cities Security inspection 50-254/98024(DRS); 50-265/98024(DRS).
This acknowledges receipt of a letter dated February 12,1999, signed by Mr. Joel Dimmette, Jr. of your staff which clarified the corrective action for the violation identified in NRC Quad Cities Security inspection 50-254/98024(DRS); 50-265/98024(DRS).


As stated in Mr. Dimmette's letter, we had reviewed the details of the clarification to the corrective action taken for the violation with the Station Security Administrator on February 9, !
As stated in Mr. Dimmette's letter, we had reviewed the details of the clarification to the corrective action taken for the violation with the Station Security Administrator on February 9, 1999. We have no further questions at this time.
1999. We have no further questions at this time.


Sincerely,
Sincerely,
-   ,
-
,
Original Signed by John A. Grobe (for)
Original Signed by John A. Grobe (for)
Steven A. Reynolds, Deputy Director Division of Reactor Safety Docket Nos.: 50-254;50-265 License Nos.: DPR-29; DPR-30 Enclosure: Ltr dtd 2/12/99
Steven A. Reynolds, Deputy Director Division of Reactor Safety Docket Nos.: 50-254;50-265 License Nos.: DPR-29; DPR-30 Enclosure:
Ltr dtd 2/12/99
}}
}}

Revision as of 20:55, 6 December 2024

Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Security Insp Repts 50-254/98-24 & 50-265/98-24
ML20207J947
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 03/10/1999
From: Reynolds S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Kingsley O
COMMONWEALTH EDISON CO.
References
50-254-98-24, 50-265-98-24, NUDOCS 9903160444
Download: ML20207J947 (2)


Text

March 10, 1999

SUBJECT:

NRC QUAD CITIES SECURITY INSPECTION REPORTS 50-254/98024(DRS);

50-265/98024(DRS)

!

Dear Mr. Kingsley:

This acknowledges receipt of a letter dated February 12,1999, signed by Mr. Joel Dimmette, Jr. of your staff which clarified the corrective action for the violation identified in NRC Quad Cities Security inspection 50-254/98024(DRS); 50-265/98024(DRS).

As stated in Mr. Dimmette's letter, we had reviewed the details of the clarification to the corrective action taken for the violation with the Station Security Administrator on February 9, 1999. We have no further questions at this time.

Sincerely,

-

,

Original Signed by John A. Grobe (for)

Steven A. Reynolds, Deputy Director Division of Reactor Safety Docket Nos.: 50-254;50-265 License Nos.: DPR-29; DPR-30 Enclosure:

Ltr dtd 2/12/99