IR 05000445/2020410: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot change) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 31: | Line 31: | ||
Sincerely, | Sincerely, | ||
/RA James R. Larsen Acting for/ | /RA James R. Larsen Acting for/ | ||
Ray L. Kellar, P.E., Chief Plant Support Branch 1 Division of Reactor Safety Docket Nos. 05000445 and 05000446 License Nos. NPF-87 and NPF-89 | |||
Ray L. Kellar, P.E., Chief Plant Support Branch 1 Division of Reactor Safety | |||
Docket Nos. 05000445 and 05000446 License Nos. NPF-87 and NPF-89 | |||
===Enclosure:=== | ===Enclosure:=== | ||
As stated | As stated | ||
==Inspection Report== | ==Inspection Report== | ||
Docket Numbers: 05000445 and 05000446 License Numbers: NPF-87 and NPF-89 Report Numbers: 05000445/2020410 and 05000446/2020410 Enterprise Identifier: I-2020-410-0004 Licensee: Vistra Operations Company LLC Facility: Comanche Peak Nuclear Power Plant Location: Glen Rose, TX Inspection Dates: August 24, 2020 to August 27, 2020 Inspectors: D. Holman, Sr Physical Security Inspector Approved By: Ray L. Kellar, P.E., Chief Plant Support Branch 1 Division of Reactor Safety | Docket Numbers: | ||
05000445 and 05000446 | |||
License Numbers: | |||
NPF-87 and NPF-89 | |||
Report Numbers: | |||
05000445/2020410 and 05000446/2020410 | |||
Enterprise Identifier: I-2020-410-0004 | |||
Licensee: | |||
Vistra Operations Company LLC | |||
Facility: | |||
Comanche Peak Nuclear Power Plant | |||
Location: | |||
Glen Rose, TX | |||
Inspection Dates: | |||
August 24, 2020 to August 27, 2020 | |||
Inspectors: | |||
D. Holman, Sr Physical Security Inspector | |||
Approved By: | |||
Ray L. Kellar, P.E., Chief | |||
Plant Support Branch 1 | |||
Division of Reactor Safety | |||
=SUMMARY= | =SUMMARY= | ||
| Line 44: | Line 76: | ||
===List of Findings and Violations=== | ===List of Findings and Violations=== | ||
No findings or violations of more than minor significance were identified. | No findings or violations of more than minor significance were identified. | ||
| Line 56: | Line 87: | ||
==SAFEGUARDS== | ==SAFEGUARDS== | ||
==71130.02 - Access Control== | ==71130.02 - Access Control== | ||
===Access Control (1 Sample)=== | ===Access Control (1 Sample)=== | ||
(1) | |||
* Tier I: All Requirements | * Tier I: All Requirements | ||
* Tier II: 6 Requirements (02.08 a-e and g) | * Tier II: 6 Requirements (02.08 a-e and g) | ||
* Tier III: 1 Requirement (02.09) | * Tier III: 1 Requirement (02.09) | ||
==71130.09 - Security Plan Changes== | ==71130.09 - Security Plan Changes== | ||
The inspectors evaluated the security plan changes through completion of the following procedure elements: | |||
===Review Security Plan Changes (IP Section 02.01) (1 Sample)=== | |||
=== | |||
: (1) The opportunity to apply this procedure was not available in accordance with Inspection Manual Chapter 0306. This sample was not available because the licensee did not conduct the activity covered by this IP. Specifically, the licensee has not initiated a physical security plan change in accordance with 10 CFR 50.54(p)(2)since the implementation of this IP. | : (1) The opportunity to apply this procedure was not available in accordance with Inspection Manual Chapter 0306. This sample was not available because the licensee did not conduct the activity covered by this IP. Specifically, the licensee has not initiated a physical security plan change in accordance with 10 CFR 50.54(p)(2)since the implementation of this IP. | ||
==OTHER ACTIVITIES - BASELINE== | ==OTHER ACTIVITIES - BASELINE== | ||
===71151 - Performance Indicator Verification | |||
The inspectors verified licensee performance indicators submittals listed below: | |||
PP01: Protected Area Security Equipment Performance Index Sample (IP Section 02.17) | |||
=== | === | ||
{{IP sample|IP=IP 71151|count=1}} | {{IP sample|IP=IP 71151|count=1}} | ||
The inspector verified performance indicator data listed below: | The inspector verified performance indicator data listed below: | ||
: (1) October 2019 through June | : (1) October 2019 through June | ||
| Line 90: | Line 122: | ||
=DOCUMENTS REVIEWED= | =DOCUMENTS REVIEWED= | ||
Inspection Type | Inspection | ||
Procedure | |||
71130.02 | Type | ||
Designation | |||
Corrective Action | Description or Title | ||
Revision or | |||
Date | |||
71130.02 | |||
20-006325 | Corrective Action | ||
Documents | |||
2019-007675 | |||
Keys in emergency vehicles | |||
10/2/19 | |||
2019-008490 | |||
Discovered contraband in x-Ray | |||
11/4/19 | |||
Corrective Action | |||
Documents | |||
Resulting from | |||
Inspection | |||
20-006290 | |||
NRC observation about FAC entry sign | |||
8/27/20 | |||
20-006322 | |||
NRC observation, exit side PCMs have gaps that can be | |||
circumvented | |||
8/27/20 | |||
20-006324 | |||
Minor violation of 10 CFR 73.22 protection of safeguards. | |||
8/27/20 | |||
20-006325 | |||
Minor violation for rusted security padlocks not included in | |||
the maintenance program. | the maintenance program. | ||
20-006327 | 8/27/20 | ||
20-006337 | 20-006327 | ||
NRC observation, SFRs lack necessary details | |||
8/27/20 | |||
20-006337 | |||
Form SEC-506-12 verbiage does not match verbiage used in | |||
body of procedure. | body of procedure. | ||
20-006360 | 8/27/20 | ||
20-006360 | |||
Minor violation of 10 CFR 73.55(c)(7)(i) security procedures | |||
with "should" instead of "shall" | with "should" instead of "shall" | ||
Miscellaneous | 8/28/20 | ||
Miscellaneous | |||
Email to Security | |||
Supervisors | Supervisors | ||
From: | |||
: [[contact:: | : [[contact::J. Jurado]], Subject: SFR and IRs | ||
8/20/20 | |||
Email to Security | |||
Supervisors | Supervisors | ||
SAS Key Cabinet | From: | ||
: [[contact::R. Brock]], Subject: Post 13 Presentation | |||
3/29/18 | |||
SFR 0011-20 | SAS Key Cabinet | ||
SFR 0020-20 | Issue/Turn-in Log | ||
SFR 0145-20 | SGI Key | ||
SFR 0146-20 | 10/22/18 to 10/25/18 | ||
SFR 0147-20 | and | ||
SFR 0171-20 | 11/17/18 to 11/29/18 | ||
SFR 0465-18 | See | ||
Procedures | Description | ||
CPNPP SI 3.11 | SFR 0011-20 | ||
CPNPP SI 3.13 | Unsatisfactory Job performance | ||
CPNPP SOP | 1/8/20 | ||
SFR 0020-20 | |||
On Duty without all Equipment | |||
1/13/20 | |||
SFR 0145-20 | |||
Unsatisfactory Job Performance | |||
4/26/20 | |||
SFR 0146-20 | |||
Unsatisfactory Job Performance | |||
4/26/20 | |||
SFR 0147-20 | |||
Assumed post without duty equipment | |||
4/26/20 | |||
SFR 0171-20 | |||
For Cause Hold | |||
5/7/20 | |||
SFR 0465-18 | |||
SGI Safe | |||
10/25/18 | |||
Procedures | |||
CPNPP SI 1.0 | |||
Common Instructions | |||
Revision 41 | |||
CPNPP SI 3.11 | |||
Key Control | |||
Revision 24 | |||
CPNPP SI 3.13 | |||
Key Card Control | |||
Revision 52 | |||
CPNPP SOP | |||
SEC-120 | SEC-120 | ||
Inspection Type | Unescorted Access Authorization | ||
Revision 11 | |||
CPNPP SOP | |||
Inspection | |||
CPNPP SOP | Procedure | ||
Type | |||
CPNPP STA-902 Access To CPNPP Site Areas | Designation | ||
Work Orders 5847504 | Description or Title | ||
5908056 | Revision or | ||
5918090 | Date | ||
CPNPP SOP | |||
SEC-302 | |||
Personnel Identification, Key Card Badge Issuance, and | |||
Access Control | |||
Revision 19 | |||
CPNPP SOP | |||
SEC306 | |||
Lock, Key, Password, Combinations and Key Card Badge | |||
Control System | |||
Revision 27 | |||
CPNPP STA-902 | |||
Access To CPNPP Site Areas | |||
Revision 26 | |||
Work Orders | |||
5847504 | |||
Monthly Inspection, CPX-SCEQPD-03 | |||
2/4/20 | |||
5908056 | |||
Monthly Inspection, CPX-SCEQPD-03 | |||
6/22/20 | |||
5918090 | |||
Monthly Inspection, CPX-SCEQPD-03 | |||
7/20/20 | |||
}} | }} | ||
Latest revision as of 13:44, 30 November 2024
| ML20254A349 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 09/10/2020 |
| From: | Ray Kellar Plant Support Branch-1 |
| To: | Peters K Vistra Operations Company |
| References | |
| IR 2020410 | |
| Download: ML20254A349 (8) | |
Text
September 10, 2020
SUBJECT:
COMANCHE PEAK NUCLEAR POWER PLANT - SECURITY BASELINE INSPECTION REPORT 05000445/2020410 AND 05000446/2020410
Dear Mr. Peters:
On August 27, 2020, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Comanche Peak Nuclear Power Plant. The NRC inspectors discussed the results of this inspection with Mr. T. McCool, Site Vice President, and other members of your staff. The results of this inspection are documented in the enclosed report.
No findings or violations of more than minor significance were identified during this inspection.
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely,
/RA James R. Larsen Acting for/
Ray L. Kellar, P.E., Chief Plant Support Branch 1 Division of Reactor Safety
Docket Nos. 05000445 and 05000446 License Nos. NPF-87 and NPF-89
Enclosure:
As stated
Inspection Report
Docket Numbers:
05000445 and 05000446
License Numbers:
Report Numbers:
05000445/2020410 and 05000446/2020410
Enterprise Identifier: I-2020-410-0004
Licensee:
Vistra Operations Company LLC
Facility:
Comanche Peak Nuclear Power Plant
Location:
Glen Rose, TX
Inspection Dates:
August 24, 2020 to August 27, 2020
Inspectors:
D. Holman, Sr Physical Security Inspector
Approved By:
Ray L. Kellar, P.E., Chief
Plant Support Branch 1
Division of Reactor Safety
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a security baseline inspection at Comanche Peak Nuclear Power Plant, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations
No findings or violations of more than minor significance were identified.
Additional Tracking Items
None.
INSPECTION SCOPES
Unless otherwise noted, baseline security inspections were conducted in accordance with the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards. Publicly available IPs are located at:
http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.
SAFEGUARDS
71130.02 - Access Control
Access Control (1 Sample)
(1)
- Tier I: All Requirements
- Tier II: 6 Requirements (02.08 a-e and g)
- Tier III: 1 Requirement (02.09)
71130.09 - Security Plan Changes
The inspectors evaluated the security plan changes through completion of the following procedure elements:
Review Security Plan Changes (IP Section 02.01) (1 Sample)
- (1) The opportunity to apply this procedure was not available in accordance with Inspection Manual Chapter 0306. This sample was not available because the licensee did not conduct the activity covered by this IP. Specifically, the licensee has not initiated a physical security plan change in accordance with 10 CFR 50.54(p)(2)since the implementation of this IP.
OTHER ACTIVITIES - BASELINE
===71151 - Performance Indicator Verification
The inspectors verified licensee performance indicators submittals listed below:
PP01: Protected Area Security Equipment Performance Index Sample (IP Section 02.17)
=
The inspector verified performance indicator data listed below:
- (1) October 2019 through June
INSPECTION RESULTS
No findings were identified.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
- On August 27, 2020, the inspectors presented the security baseline inspection results to Mr. T. McCool, Site Vice President, and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Corrective Action
Documents
2019-007675
Keys in emergency vehicles
10/2/19
2019-008490
Discovered contraband in x-Ray
11/4/19
Corrective Action
Documents
Resulting from
Inspection
20-006290
NRC observation about FAC entry sign
8/27/20
20-006322
NRC observation, exit side PCMs have gaps that can be
circumvented
8/27/20
20-006324
Minor violation of 10 CFR 73.22 protection of safeguards.
8/27/20
20-006325
Minor violation for rusted security padlocks not included in
the maintenance program.
8/27/20
20-006327
NRC observation, SFRs lack necessary details
8/27/20
20-006337
Form SEC-506-12 verbiage does not match verbiage used in
body of procedure.
8/27/20
20-006360
Minor violation of 10 CFR 73.55(c)(7)(i) security procedures
with "should" instead of "shall"
8/28/20
Miscellaneous
Email to Security
Supervisors
From:
- J. Jurado, Subject: SFR and IRs
8/20/20
Email to Security
Supervisors
From:
- R. Brock, Subject: Post 13 Presentation
3/29/18
SAS Key Cabinet
Issue/Turn-in Log
SGI Key
10/22/18 to 10/25/18
and
11/17/18 to 11/29/18
See
Description
SFR 0011-20
Unsatisfactory Job performance
1/8/20
SFR 0020-20
On Duty without all Equipment
1/13/20
SFR 0145-20
Unsatisfactory Job Performance
4/26/20
SFR 0146-20
Unsatisfactory Job Performance
4/26/20
SFR 0147-20
Assumed post without duty equipment
4/26/20
SFR 0171-20
For Cause Hold
5/7/20
SFR 0465-18
SGI Safe
10/25/18
Procedures
Common Instructions
Revision 41
Key Control
Revision 24
Key Card Control
Revision 52
Unescorted Access Authorization
Revision 11
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Personnel Identification, Key Card Badge Issuance, and
Access Control
Revision 19
Lock, Key, Password, Combinations and Key Card Badge
Control System
Revision 27
CPNPP STA-902
Access To CPNPP Site Areas
Revision 26
Work Orders
5847504
Monthly Inspection, CPX-SCEQPD-03
2/4/20
5908056
Monthly Inspection, CPX-SCEQPD-03
6/22/20
5918090
Monthly Inspection, CPX-SCEQPD-03
7/20/20