IR 07200202/2000001: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot change)
(StriderTol Bot change)
Line 1: Line 1:
{{Adams
{{Adams
| number = ML20337A108
| number = ML20346A100
| issue date = 12/02/2020
| issue date = 11/06/2020
| title = Jan X-Ray Services, Inc. - NRC Form 592M, Inspection Report 03011772/2020001 (DNMS)
| title = C&C Irradiator Service, LLC, NRC Form 591M Part 1, Inspection Report No. 03039072/2020001
| author name = Craffey R, Song T
| author name = Ragland R
| author affiliation = NRC/RGN-III/DRMA
| author affiliation = NRC/RGN-I/DNMS
| addressee name = Frazee T
| addressee name =  
| addressee affiliation = JAN X-ray Services, Inc
| addressee affiliation = C&C Irradiator Service, LLC
| docket = 03011772
| docket = 03039072
| license number = 21-16560-01  
| license number = 08-35447-01
| contact person =  
| contact person =  
| document report number = IR 2020001
| document report number = IR 2020001
| document type = Inspection Report
| document type = Inspection Report, Safety and Compliance Inspection Record, NRC Form 591
| page count = 1
| page count = 1
}}
}}
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:Please wait...
{{#Wiki_filter:NRC FORM 591M PART 1      U.S. NUCLEAR REGULATORY COMMISSION (07-2012)*
If this message is not eventually replaced by the proper contents of the document, your PDF viewer may not be able to display this type of document.
10 CFR 2.201 SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION 1. LICENSEE/LOCATION INSPECTED:    2. NRC/REGIONAL OFFICE C&C Irradiator Service, LLC 1030 Evarts Street, NE    U.S. Nuclear Regulatory Commission Washington, DC 20018 & Indianapolis, IN jobsite  Region I, 2100 Renaissance Blvd, Suite 100 King of Prussia, Pennsylvania 19406-2713 REPORT NUMBER(S)  2020-001 3. DOCKET NUMBER(S)  4. LICENSE NUMBER(S)  5. DATE(S) OF INSPECTION 030-39072  08-35447-01  October 10 - 17, and 11/06/2020 LICENSEE:
 
The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows:
You can upgrade to the latest version of Adobe Reader for Windows, Mac, or Linux by visiting http://www.adobe.com/go/reader_download.
x 1. Based on the inspection findings, no violations were identifie . Previous violation(s) close . The violation(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy, to exercise discretion, were satisfie Non-cited violation(s) were discussed involving the following requirement(s) and corrective action(s):
 
4. During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements and are being cited in accordance with the NRC Enforcement Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.11. (Violations and Corrective Actions)
For more assistance with Adobe Reader visit http://www.adobe.com/go/acrreader.
Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified. This statement of corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requeste Title  Printed Name  Signature  Date LICENSEES REPRESENTATIVE NRC INSPECTOR  Deborah A. Piskura, Sr. Health Physicist Randolph C. Ragland Digitally signed by Randolph C. Ragland Date: 2020.11.09 14:22:13 -05'00'
 
Randolph Ragland, Sr. Health Physicist RCR for DAP BRANCH CHIEF    Christopher G. Cahill Digitally signed by Christopher G. Cahill Date: 2020.11.09 15:19:30 -05'00'
Windows is either a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries. Mac is a trademark of Apple Inc., registered in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.
*NRC FORM 591M PART 1 (07-2012) (RI Rev. 09/12/2013)  G:\WBL Documents\WBL Inspection Records\R08-35447-01.2020001.591M-Part1.doc SUNSI Review Completed By:  / RA / R. C. Ragland  x Public x Non-Sensitive This document becomes an NRC Official Agency Record once it is signed by the Branch Chief
}}
}}

Revision as of 01:15, 7 February 2021

C&C Irradiator Service, LLC, NRC Form 591M Part 1, Inspection Report No. 03039072/2020001
ML20346A100
Person / Time
Site: 07200202, 03039072
Issue date: 11/06/2020
From: Randolph Ragland
Division of Nuclear Materials Safety I
To:
C&C Irradiator Service
References
IR 2020001
Download: ML20346A100 (1)


Text

NRC FORM 591M PART 1 U.S. NUCLEAR REGULATORY COMMISSION (07-2012)*

10 CFR 2.201 SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION 1. LICENSEE/LOCATION INSPECTED: 2. NRC/REGIONAL OFFICE C&C Irradiator Service, LLC 1030 Evarts Street, NE U.S. Nuclear Regulatory Commission Washington, DC 20018 & Indianapolis, IN jobsite Region I, 2100 Renaissance Blvd, Suite 100 King of Prussia, Pennsylvania 19406-2713 REPORT NUMBER(S) 2020-001 3. DOCKET NUMBER(S) 4. LICENSE NUMBER(S) 5. DATE(S) OF INSPECTION 030-39072 08-35447-01 October 10 - 17, and 11/06/2020 LICENSEE:

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows:

x 1. Based on the inspection findings, no violations were identifie . Previous violation(s) close . The violation(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy, to exercise discretion, were satisfie Non-cited violation(s) were discussed involving the following requirement(s) and corrective action(s):

4. During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements and are being cited in accordance with the NRC Enforcement Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.11. (Violations and Corrective Actions)

Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified. This statement of corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requeste Title Printed Name Signature Date LICENSEES REPRESENTATIVE NRC INSPECTOR Deborah A. Piskura, Sr. Health Physicist Randolph C. Ragland Digitally signed by Randolph C. Ragland Date: 2020.11.09 14:22:13 -05'00'

Randolph Ragland, Sr. Health Physicist RCR for DAP BRANCH CHIEF Christopher G. Cahill Digitally signed by Christopher G. Cahill Date: 2020.11.09 15:19:30 -05'00'

  • NRC FORM 591M PART 1 (07-2012) (RI Rev. 09/12/2013) G:\WBL Documents\WBL Inspection Records\R08-35447-01.2020001.591M-Part1.doc SUNSI Review Completed By: / RA / R. C. Ragland x Public x Non-Sensitive This document becomes an NRC Official Agency Record once it is signed by the Branch Chief